The Project Gutenberg eBook of Steam, Its Generation and Use
This eBook is for the use of anyone anywhere in the United States and most
other parts of the world at no cost and with almost no restrictions
whatsoever. You may copy it, give it away or re-use it under the terms of the
Project Gutenberg License included with this eBook or online at
www.gutenberg.org. If you are not located in the United States, you will
have to check the laws of the country where you are located before using this
eBook.
Title: Steam, Its Generation and Use
Author: Babcock & Wilcox Company
Release date: September 18, 2007 [eBook #22657]
Most recently updated: June 29, 2021
Language: English
Other information and formats: www.gutenberg.org/ebooks/22657
Credits: Juliet Sutherland, Tony Browne, and the Online Distributed
Proofreading Team
*** START OF THE PROJECT GUTENBERG EBOOK STEAM, ITS
GENERATION AND USE ***
This eBook is for the use of anyone anywhere in the United States and most
other parts of the world at no cost and with almost no restrictions
whatsoever. You may copy it, give it away or re-use it under the terms of the
Project Gutenberg License included with this eBook or online at
www.gutenberg.org. If you are not located in the United States, you will
have to check the laws of the country where you are located before using this
eBook.
Title: Steam, Its Generation and Use
Author: Babcock & Wilcox Company
Release date: September 18, 2007 [eBook #22657]
Most recently updated: June 29, 2021
Language: English
Other information and formats: www.gutenberg.org/ebooks/22657
Credits: Juliet Sutherland, Tony Browne, and the Online Distributed
Proofreading Team
*** START OF THE PROJECT GUTENBERG EBOOK STEAM, ITS
GENERATION AND USE ***
Page 4
Steam: its Generation and Use
TRANSCRIBER'S TABLE OF CONTENTS—CHAPTERS
Chapter
LIST OF ILLUSTRATIONS
TITLE PAGE
The Early History of the Generation and Use of Steam
Brief History of Water-tube Boilers
Requirements of Steam Boilers
Evolution of the Babcock & Wilcox Water-tube Boiler
The Babcock & Wilcox Boiler
Advantages of the Babcock & Wilcox Boiler
Heat and its Measurement
The Theory of Steam Making
Properties of Water
Boiler Feed Water
Feed Water Heating and Methods of Feeding
Steam
Moisture in Steam
Superheated Steam
Properties of Air
Combustion
Analysis of Flue Gases
Classification of Fuels
The Determination of Heating Values of Fuels
Combustion of Coal
Solid Fuels other than Coal and their Combustion
Liquid Fuels and their Combustion
Gaseous Fuels and their Combustion
Utilization of Waste Heat
Chimneys and Draft
Efficiency and Capacity of Boilers
TRANSCRIBER'S TABLE OF CONTENTS—CHAPTERS
Chapter
LIST OF ILLUSTRATIONS
TITLE PAGE
The Early History of the Generation and Use of Steam
Brief History of Water-tube Boilers
Requirements of Steam Boilers
Evolution of the Babcock & Wilcox Water-tube Boiler
The Babcock & Wilcox Boiler
Advantages of the Babcock & Wilcox Boiler
Heat and its Measurement
The Theory of Steam Making
Properties of Water
Boiler Feed Water
Feed Water Heating and Methods of Feeding
Steam
Moisture in Steam
Superheated Steam
Properties of Air
Combustion
Analysis of Flue Gases
Classification of Fuels
The Determination of Heating Values of Fuels
Combustion of Coal
Solid Fuels other than Coal and their Combustion
Liquid Fuels and their Combustion
Gaseous Fuels and their Combustion
Utilization of Waste Heat
Chimneys and Draft
Efficiency and Capacity of Boilers
Page 5
The Selection of Boilers with a Consideration of the Factors Determining
such Selection
Operation and Care of Boilers
Brickwork Boiler Settings
Boiler Room Piping
Flow of Steam through Pipes and Orifices
Heat Transfer
INDEX
TRANSCRIBER'S LIST OF
ILLUSTRATIONS
Illustration
Works at Bayonne
Works at Barberton
Works at Renfrew
Fonderies et Ateliers
Longitudinal Drum Boiler
Boiler at Ampere
Boilers and Superheaters in Chicago
Erie County Electric Co.
Boilers and Superheaters at Blue Island
Woolworth Building
Boilers in Philadelphia
Boilers in Boston
Boilers and Superheaters in South Boston
Boilers in Johnstown
Boilers and Superheaters in South Boston
Boilers in Pittsburgh
Longitudinal Drum Boiler
Cross Drum Boiler
Longitudinal Drum Boiler
Longitudinal Drum Boiler
Longitudinal Drum Boiler
Cross Drum Boiler
such Selection
Operation and Care of Boilers
Brickwork Boiler Settings
Boiler Room Piping
Flow of Steam through Pipes and Orifices
Heat Transfer
INDEX
TRANSCRIBER'S LIST OF
ILLUSTRATIONS
Illustration
Works at Bayonne
Works at Barberton
Works at Renfrew
Fonderies et Ateliers
Longitudinal Drum Boiler
Boiler at Ampere
Boilers and Superheaters in Chicago
Erie County Electric Co.
Boilers and Superheaters at Blue Island
Woolworth Building
Boilers in Philadelphia
Boilers in Boston
Boilers and Superheaters in South Boston
Boilers in Johnstown
Boilers and Superheaters in South Boston
Boilers in Pittsburgh
Longitudinal Drum Boiler
Cross Drum Boiler
Longitudinal Drum Boiler
Longitudinal Drum Boiler
Longitudinal Drum Boiler
Cross Drum Boiler
Page 6
Boilers in Boston
McAlpin Hotel
Northwest Station Chicago
Vertical Header Boiler
Boilers in Raritan
Boilers in Pittsburgh
Ninety-sixth Street Station in New York
Boiler in Boston
Boilers and Superheaters in Chicago
Boilers and Superheaters in Washington
Boilers and Superheaters in Passaic
Boilers and Superheaters in Washington
Boilers in Newark
Boilers in Louisville
Superheater
Boilers and Superheaters in Atlanta
Boilers and Superheaters in Chicago
Boilers and Superheaters in New York City
Boilers and Superheaters in Pittsburgh
Boilers and Superheaters in Washington
Chain Grate Stoker
Boilers in Portland
Boiler and Superheater in Quincy
Boilers in San Francisco
Boiler with Oil Furnace
Boilers in Bethlehem
Boiler and Superheaters in Underwood
Boilers and Superheaters in Chicago
Boilers in Washington
Boilers in Chicago
Boilers in Northumberland
Boilers in Chicago
Boilers in Chicago
Boilers in Chicago
McAlpin Hotel
Northwest Station Chicago
Vertical Header Boiler
Boilers in Raritan
Boilers in Pittsburgh
Ninety-sixth Street Station in New York
Boiler in Boston
Boilers and Superheaters in Chicago
Boilers and Superheaters in Washington
Boilers and Superheaters in Passaic
Boilers and Superheaters in Washington
Boilers in Newark
Boilers in Louisville
Superheater
Boilers and Superheaters in Atlanta
Boilers and Superheaters in Chicago
Boilers and Superheaters in New York City
Boilers and Superheaters in Pittsburgh
Boilers and Superheaters in Washington
Chain Grate Stoker
Boilers in Portland
Boiler and Superheater in Quincy
Boilers in San Francisco
Boiler with Oil Furnace
Boilers in Bethlehem
Boiler and Superheaters in Underwood
Boilers and Superheaters in Chicago
Boilers in Washington
Boilers in Chicago
Boilers in Northumberland
Boilers in Chicago
Boilers in Chicago
Boilers in Chicago
Page 7
Boilers in Minneapolis
Boilers in Billings
Boilers and Superheaters in East Pittsburgh
Boilers and Superheaters in Long Island City
Boilers in Chicago
Boiler Casing
Boilers and Superheaters in Louisville
Bankers Trust Building
Vesta Coal Co.
Iron City Brewery
[Pg 1]
STEAM
ITS GENERATION AND USE
Boilers in Billings
Boilers and Superheaters in East Pittsburgh
Boilers and Superheaters in Long Island City
Boilers in Chicago
Boiler Casing
Boilers and Superheaters in Louisville
Bankers Trust Building
Vesta Coal Co.
Iron City Brewery
[Pg 1]
STEAM
ITS GENERATION AND USE
Page 8
THE BABCOCK & WILCOX CO.
Page 9
NEW YORK
Pg 2]
Thirty-fifth Edition
4th Issue
Copyright, 1919, by The Babcock & Wilcox Co.
Bartlett Orr Press
New York
[Pg 3]
Pg 2]
Thirty-fifth Edition
4th Issue
Copyright, 1919, by The Babcock & Wilcox Co.
Bartlett Orr Press
New York
[Pg 3]
Page 10
THE BABCOCK & WILCOX CO.
85 LIBERTY STREET, NEW YORK, U. S. A.
Works
BAYONNE NEW JERSEY
BARBERTON OHIO
Officers
W. D. HOXIE, President
E. H. WELLS, Chairman of the Board
A. G. PRATT, Vice-President
Branch Offices
ATLANTA Candler Building
BOSTON 35 Federal Street
CHICAGO Marquette Building
CINCINNATI Traction Building
CLEVELAND New Guardian Building
DENVER 435 Seventeenth Street
HAVANA, CUBA 104 Calle de Aguiar
HOUSTON Southern Pacific Building
LOS ANGELES I. N. Van Nuy’s Building
NEW ORLEANS Shubert Arcade
PHILADELPHIA North American Building
PITTSBURGH Farmers’ Deposit Bank Building
SALT LAKE CITY Kearns Building
85 LIBERTY STREET, NEW YORK, U. S. A.
Works
BAYONNE NEW JERSEY
BARBERTON OHIO
Officers
W. D. HOXIE, President
E. H. WELLS, Chairman of the Board
A. G. PRATT, Vice-President
Branch Offices
ATLANTA Candler Building
BOSTON 35 Federal Street
CHICAGO Marquette Building
CINCINNATI Traction Building
CLEVELAND New Guardian Building
DENVER 435 Seventeenth Street
HAVANA, CUBA 104 Calle de Aguiar
HOUSTON Southern Pacific Building
LOS ANGELES I. N. Van Nuy’s Building
NEW ORLEANS Shubert Arcade
PHILADELPHIA North American Building
PITTSBURGH Farmers’ Deposit Bank Building
SALT LAKE CITY Kearns Building
Page 11
SAN FRANCISCO Sheldon Building
SEATTLE L. C. Smith Building
TUCSON, ARIZ. Santa Rita Hotel Building
SAN JUAN, PORTO RICO Royal Bank Building
Export Department, New York: Alberto de Verastegni, Director
TELEGRAPHIC ADDRESS: FOR NEW YORK,
“GLOVEBOXES”
FOR HAVANA, “BABCOCK”
[Pg 4]
Works of The Babcock & Wilcox Co., at Bayonne, New Jersey
[Pg 5]
[Pg 6]
SEATTLE L. C. Smith Building
TUCSON, ARIZ. Santa Rita Hotel Building
SAN JUAN, PORTO RICO Royal Bank Building
Export Department, New York: Alberto de Verastegni, Director
TELEGRAPHIC ADDRESS: FOR NEW YORK,
“GLOVEBOXES”
FOR HAVANA, “BABCOCK”
[Pg 4]
Works of The Babcock & Wilcox Co., at Bayonne, New Jersey
[Pg 5]
[Pg 6]
Page 12
Works of The Babcock & Wilcox Co., at Barberton, Ohio
[Pg 7]
[Pg 8]
[Pg 7]
[Pg 8]
Page 13
Works of Babcock & Wilcox, Limited, Renfrew, SCOTLAND
[Pg 9]
[Pg 9]
Page 14
BABCOCK & WILCOX Limited
ORIEL HOUSE, FARRINGDON STREET, LONDON, E. C.
WORKS: RENFREW, SCOTLAND
Directors
JOHN DEWRANCE, Chairman CHARLES A. KNIGHT
ARTHUR T. SIMPSON J. H. R. KEMNAL
WILLIAM D. HOXIE Managing Director
E. H. WELLS WALTER COLLS, Secretary
Branch Offices in Great Britain
GLASGOW: 29 St. Vincent Place MANCHESTER: 30 Cross Street
MIDDLESBROUGH: The
BIRMINGHAM: Winchester House
Exchange
CARDIFF: 129 Bute Street NEWCASTLE: 42 Westgate Road
BELFAST: Ocean Buildings, Donegal SHEFFIELD: 14 Bank Chambers,
Square, E. Fargate
Offices Abroad
BOMBAY: Wheeler’s Building, Hornby MELBOURNE: 9 William
Road, Fort Street
BRUSSELS: 187 Rue Royal MEXICO: 22-23 Tiburcio
MILAN: 22 Via Principe
BILBAO: 1 Plaza de Albia
Umberto
MONTREAL: College Street,
CALCUTTA: Clive Building
St. Henry
ORIEL HOUSE, FARRINGDON STREET, LONDON, E. C.
WORKS: RENFREW, SCOTLAND
Directors
JOHN DEWRANCE, Chairman CHARLES A. KNIGHT
ARTHUR T. SIMPSON J. H. R. KEMNAL
WILLIAM D. HOXIE Managing Director
E. H. WELLS WALTER COLLS, Secretary
Branch Offices in Great Britain
GLASGOW: 29 St. Vincent Place MANCHESTER: 30 Cross Street
MIDDLESBROUGH: The
BIRMINGHAM: Winchester House
Exchange
CARDIFF: 129 Bute Street NEWCASTLE: 42 Westgate Road
BELFAST: Ocean Buildings, Donegal SHEFFIELD: 14 Bank Chambers,
Square, E. Fargate
Offices Abroad
BOMBAY: Wheeler’s Building, Hornby MELBOURNE: 9 William
Road, Fort Street
BRUSSELS: 187 Rue Royal MEXICO: 22-23 Tiburcio
MILAN: 22 Via Principe
BILBAO: 1 Plaza de Albia
Umberto
MONTREAL: College Street,
CALCUTTA: Clive Building
St. Henry
Page 15
JOHANNESBURG: Consolidated
NAPLES: 107 Via Santa Lucia
Buildings
LIMA: Peru SHANGHAI: 1a Jinkee Road
SYDNEY: 427-429 Sussex
LISBON: 84-86 Rua do Commercio
Street
MADRID: Ventura de la Vega TOKYO: Japan
TORONTO: Traders’ Bank Building
Representatives and Licensees in
ADELAIDE, South
CAIRO, Egypt MOSCOW, Russia
Australia
CHILE, Valparaiso, So. PERTH, Western
ATHENS, Greece
America Australia
AUCKLAND, New
CHRISTIANIA, Norway POLAND, Berlin
Zealand
BAHIA, Brazil COLOMBO, Ceylon RANGOON, Burma
COPENHAGEN, RIO DE JANEIRO,
BANGKOK, Siam
Denmark Brazil
SMYRNA, Asia
BARCELONA, Spain ESKILSTUNA, Sweden
Minor
BRUNN, Austria GIJON, Spain SOURABAYA, Java
BUCHAREST, HELSINGFORS, ST. PETERSBURG,
Roumania Finland Russia
TAMMERFORS,
BUDAPEST, Hungary HENGELO, Holland
Finland
BUENOS AYRES, KIMBERLEY, South THE HAGUE,
Argentine Rep. Africa Holland
TELEGRAPHIC ADDRESS FOR ALL OFFICES EXCEPT BOMBAY
AND CALCUTTA: “BABCOCK”
FOR BOMBAY AND CALCUTTA: “BOILER”
[Pg 10]
NAPLES: 107 Via Santa Lucia
Buildings
LIMA: Peru SHANGHAI: 1a Jinkee Road
SYDNEY: 427-429 Sussex
LISBON: 84-86 Rua do Commercio
Street
MADRID: Ventura de la Vega TOKYO: Japan
TORONTO: Traders’ Bank Building
Representatives and Licensees in
ADELAIDE, South
CAIRO, Egypt MOSCOW, Russia
Australia
CHILE, Valparaiso, So. PERTH, Western
ATHENS, Greece
America Australia
AUCKLAND, New
CHRISTIANIA, Norway POLAND, Berlin
Zealand
BAHIA, Brazil COLOMBO, Ceylon RANGOON, Burma
COPENHAGEN, RIO DE JANEIRO,
BANGKOK, Siam
Denmark Brazil
SMYRNA, Asia
BARCELONA, Spain ESKILSTUNA, Sweden
Minor
BRUNN, Austria GIJON, Spain SOURABAYA, Java
BUCHAREST, HELSINGFORS, ST. PETERSBURG,
Roumania Finland Russia
TAMMERFORS,
BUDAPEST, Hungary HENGELO, Holland
Finland
BUENOS AYRES, KIMBERLEY, South THE HAGUE,
Argentine Rep. Africa Holland
TELEGRAPHIC ADDRESS FOR ALL OFFICES EXCEPT BOMBAY
AND CALCUTTA: “BABCOCK”
FOR BOMBAY AND CALCUTTA: “BOILER”
[Pg 10]
Page 16
Fonderies et Ateliers de la Courneuve, Chaudières Babcock & Wilcox,
Paris, France
[Pg 11]
FONDERIES ET ATELIERS DE LA COURNEUVE
CHAUDIÈRES
Paris, France
[Pg 11]
FONDERIES ET ATELIERS DE LA COURNEUVE
CHAUDIÈRES
Page 17
BABCOCK & WILCOX
6 RUE LAFERRIÈRE, PARIS
WORKS: SEINE—LA COURNEUVE
Directors
EDMOND DUPUIS J. H. R. KEMNAL
ETIENNE BESSON IRÉNÉE CHAVANNE
CHARLES A. KNIGHT JULES LEMAIRE
Branch Offices
BORDEAUX: 30 Boulevard Antoine Gautier
LILLE: 23 Rue Faidherbe
LYON: 28 Quai de la Guillotier
MARSEILLE: 21 Cours Devilliers
MONTPELLIER: 1 Rue Boussairolles
NANCY: 2 Rue de Lorraine
ST. ETIENNE: 13 Rue de la Bourse
REPRESENTATIVE FOR SWITZERLAND: SPOERRI & CIE,
ZURICH
TELEGRAPHIC ADDRESS: “BABCOCK-PARIS”
[Pg 12]
6 RUE LAFERRIÈRE, PARIS
WORKS: SEINE—LA COURNEUVE
Directors
EDMOND DUPUIS J. H. R. KEMNAL
ETIENNE BESSON IRÉNÉE CHAVANNE
CHARLES A. KNIGHT JULES LEMAIRE
Branch Offices
BORDEAUX: 30 Boulevard Antoine Gautier
LILLE: 23 Rue Faidherbe
LYON: 28 Quai de la Guillotier
MARSEILLE: 21 Cours Devilliers
MONTPELLIER: 1 Rue Boussairolles
NANCY: 2 Rue de Lorraine
ST. ETIENNE: 13 Rue de la Bourse
REPRESENTATIVE FOR SWITZERLAND: SPOERRI & CIE,
ZURICH
TELEGRAPHIC ADDRESS: “BABCOCK-PARIS”
[Pg 12]
Page 18
Wrought-steel Vertical Header Longitudinal Drum Babcock & Wilcox
Boiler, Equipped with Babcock & Wilcox Superheater and Babcock &
Wilcox Chain Grate Stoker
Boiler, Equipped with Babcock & Wilcox Superheater and Babcock &
Wilcox Chain Grate Stoker
Page 19
[Pg 13]
Page 20
THE EARLY HISTORY OF THE GENERATION
AND USE OF STEAM
While the time of man’s first knowledge and use of the expansive force of
the vapor of water is unknown, records show that such knowledge existed
earlier than 150 B. C. In a treatise of about that time entitled “Pneumatica”,
Hero, of Alexander, described not only existing devices of his predecessors
and contemporaries but also an invention of his own which utilized the
expansive force of steam for raising water above its natural level. He clearly
describes three methods in which steam might be used directly as a motive
of power; raising water by its elasticity, elevating a weight by its expansive
power and producing a rotary motion by its reaction on the atmosphere. The
third method, which is known as “Hero’s engine”, is described as a hollow
sphere supported over a caldron or boiler by two trunnions, one of which
was hollow, and connected the interior of the sphere with the steam space of
the caldron. Two pipes, open at the ends and bent at right angles, were
inserted at opposite poles of the sphere, forming a connection between the
caldron and the atmosphere. Heat being applied to the caldron, the steam
generated passed through the hollow trunnion to the sphere and thence into
the atmosphere through the two pipes. By the reaction incidental to its
escape through these pipes, the sphere was caused to rotate and here is the
primitive steam reaction turbine.
Hero makes no suggestions as to application of any of the devices he
describes to a useful purpose. From the time of Hero until the late sixteenth
and early seventeenth centuries, there is no record of progress, though
evidence is found that such devices as were described by Hero were
sometimes used for trivial purposes, the blowing of an organ or the turning
of a skillet.
Mathesius, the German author, in 1571; Besson, a philosopher and
mathematician at Orleans; Ramelli, in 1588; Battista Delia Porta, a
Neapolitan mathematician and philosopher, in 1601; Decause, the French
engineer and architect, in 1615; and Branca, an Italian architect, in 1629, all
published treatises bearing on the subject of the generation of steam.
AND USE OF STEAM
While the time of man’s first knowledge and use of the expansive force of
the vapor of water is unknown, records show that such knowledge existed
earlier than 150 B. C. In a treatise of about that time entitled “Pneumatica”,
Hero, of Alexander, described not only existing devices of his predecessors
and contemporaries but also an invention of his own which utilized the
expansive force of steam for raising water above its natural level. He clearly
describes three methods in which steam might be used directly as a motive
of power; raising water by its elasticity, elevating a weight by its expansive
power and producing a rotary motion by its reaction on the atmosphere. The
third method, which is known as “Hero’s engine”, is described as a hollow
sphere supported over a caldron or boiler by two trunnions, one of which
was hollow, and connected the interior of the sphere with the steam space of
the caldron. Two pipes, open at the ends and bent at right angles, were
inserted at opposite poles of the sphere, forming a connection between the
caldron and the atmosphere. Heat being applied to the caldron, the steam
generated passed through the hollow trunnion to the sphere and thence into
the atmosphere through the two pipes. By the reaction incidental to its
escape through these pipes, the sphere was caused to rotate and here is the
primitive steam reaction turbine.
Hero makes no suggestions as to application of any of the devices he
describes to a useful purpose. From the time of Hero until the late sixteenth
and early seventeenth centuries, there is no record of progress, though
evidence is found that such devices as were described by Hero were
sometimes used for trivial purposes, the blowing of an organ or the turning
of a skillet.
Mathesius, the German author, in 1571; Besson, a philosopher and
mathematician at Orleans; Ramelli, in 1588; Battista Delia Porta, a
Neapolitan mathematician and philosopher, in 1601; Decause, the French
engineer and architect, in 1615; and Branca, an Italian architect, in 1629, all
published treatises bearing on the subject of the generation of steam.
Page 21
To the next contributor, Edward Somerset, second Marquis of Worcester, is
apparently due the credit of proposing, if not of making, the first useful
steam engine. In the “Century of Scantlings and Inventions”, published in
London in 1663, he describes devices showing that he had in mind the
raising of water not only by forcing it from two receivers by direct steam
pressure but also for some sort of reciprocating piston actuating one end of a
lever, the other operating a pump. His descriptions are rather obscure and no
drawings are extant so that it is difficult to say whether there were any
distinctly novel features to his devices aside from the double action. While
there is no direct authentic record that any of the devices he described were
actually constructed, it is claimed by many that he really built and operated a
steam engine containing pistons.
In 1675, Sir Samuel Moreland was decorated by King Charles II, for a
demonstration of “a certain powerful machine to raise water.” Though there
appears to be no record of the design of this machine, the mathematical
dictionary, published in 1822, credits Moreland with the first account of a
steam engine, on which subject he wrote a treatise that is still preserved in
the British Museum.
[Pg 14]
apparently due the credit of proposing, if not of making, the first useful
steam engine. In the “Century of Scantlings and Inventions”, published in
London in 1663, he describes devices showing that he had in mind the
raising of water not only by forcing it from two receivers by direct steam
pressure but also for some sort of reciprocating piston actuating one end of a
lever, the other operating a pump. His descriptions are rather obscure and no
drawings are extant so that it is difficult to say whether there were any
distinctly novel features to his devices aside from the double action. While
there is no direct authentic record that any of the devices he described were
actually constructed, it is claimed by many that he really built and operated a
steam engine containing pistons.
In 1675, Sir Samuel Moreland was decorated by King Charles II, for a
demonstration of “a certain powerful machine to raise water.” Though there
appears to be no record of the design of this machine, the mathematical
dictionary, published in 1822, credits Moreland with the first account of a
steam engine, on which subject he wrote a treatise that is still preserved in
the British Museum.
[Pg 14]
Page 22
397 Horse-power Babcock & Wilcox Boiler in Course of Erection at the
Plant of the Crocker Wheeler Co., Ampere, N. J.
[Pg 15] Dr. Denys Papin, an ingenious Frenchman, invented in 1680 “a steam
digester for extracting marrowy, nourishing juices from bones by enclosing
them in a boiler under heavy pressure,” and finding danger from explosion,
added a contrivance which is the first safety valve on record.
The steam engine first became commercially successful with Thomas
Savery. In 1699, Savery exhibited before the Royal Society of England (Sir
Isaac Newton was President at the time), a model engine which consisted of
two copper receivers alternately connected by a three-way hand-operated
valve, with a boiler and a source of water supply. When the water in one
receiver had been driven out by the steam, cold water was poured over its
outside surface, creating a vacuum through condensation and causing it to
fill again while the water in the other reservoir was being forced out. A
number of machines were built on this principle and placed in actual use as
mine pumps.
The serious difficulty encountered in the use of Savery’s engine was the fact
that the height to which it could lift water was limited by the pressure the
boiler and vessels could bear. Before Savery’s engine was entirely displaced
by its successor, Newcomen’s, it was considerably improved by Desaguliers,
who applied the Papin safety valve to the boiler and substituted condensation
by a jet within the vessel for Savery’s surface condensation.
In 1690, Papin suggested that the condensation of steam should be employed
to make a vacuum beneath a cylinder which had previously been raised by
the expansion of steam. This was the earliest cylinder and piston steam
engine and his plan took practical shape in Newcomen’s atmospheric engine.
Papin’s first engine was unworkable owing to the fact that he used the same
vessel for both boiler and cylinder. A small quantity of water was placed in
the bottom of the vessel and heat was applied. When steam formed and
raised the piston, the heat was withdrawn and the piston did work on its
down stroke under pressure of the atmosphere. After hearing of Savery’s
engine, Papin developed an improved form. Papin’s engine of 1705
consisted of a displacement chamber in which a floating diaphragm or piston
on top of the water kept the steam and water from direct contact. The water
Plant of the Crocker Wheeler Co., Ampere, N. J.
[Pg 15] Dr. Denys Papin, an ingenious Frenchman, invented in 1680 “a steam
digester for extracting marrowy, nourishing juices from bones by enclosing
them in a boiler under heavy pressure,” and finding danger from explosion,
added a contrivance which is the first safety valve on record.
The steam engine first became commercially successful with Thomas
Savery. In 1699, Savery exhibited before the Royal Society of England (Sir
Isaac Newton was President at the time), a model engine which consisted of
two copper receivers alternately connected by a three-way hand-operated
valve, with a boiler and a source of water supply. When the water in one
receiver had been driven out by the steam, cold water was poured over its
outside surface, creating a vacuum through condensation and causing it to
fill again while the water in the other reservoir was being forced out. A
number of machines were built on this principle and placed in actual use as
mine pumps.
The serious difficulty encountered in the use of Savery’s engine was the fact
that the height to which it could lift water was limited by the pressure the
boiler and vessels could bear. Before Savery’s engine was entirely displaced
by its successor, Newcomen’s, it was considerably improved by Desaguliers,
who applied the Papin safety valve to the boiler and substituted condensation
by a jet within the vessel for Savery’s surface condensation.
In 1690, Papin suggested that the condensation of steam should be employed
to make a vacuum beneath a cylinder which had previously been raised by
the expansion of steam. This was the earliest cylinder and piston steam
engine and his plan took practical shape in Newcomen’s atmospheric engine.
Papin’s first engine was unworkable owing to the fact that he used the same
vessel for both boiler and cylinder. A small quantity of water was placed in
the bottom of the vessel and heat was applied. When steam formed and
raised the piston, the heat was withdrawn and the piston did work on its
down stroke under pressure of the atmosphere. After hearing of Savery’s
engine, Papin developed an improved form. Papin’s engine of 1705
consisted of a displacement chamber in which a floating diaphragm or piston
on top of the water kept the steam and water from direct contact. The water
Page 23
delivered by the downward movement of the piston under pressure, to a
closed tank, flowed in a continuous stream against the vanes of a water
wheel. When the steam in the displacement chamber had expanded, it was
exhausted to the atmosphere through a valve instead of being condensed.
The engine was, in fact, a non-condensing, single action steam pump with
the steam and pump cylinders in one. A curious feature of this engine was a
heater placed in the diaphragm. This was a mass of heated metal for the
purpose of keeping the steam dry or preventing condensation during
expansion. This device might be called the first superheater.
Among the various inventions attributed to Papin was a boiler with an
internal fire box, the earliest record of such construction.
While Papin had neglected his earlier suggestion of a steam and piston
engine to work on Savery’s ideas, Thomas Newcomen, with his assistant,
John Cawley, put into practical form Papin’s suggestion of 1690. Steam
admitted from the boiler to a cylinder raised a piston by its expansion,
assisted by a counter-weight on the other end of a beam actuated by the
piston. The steam valve was then shut and the steam condensed by a jet of
cold water. The piston was then forced downward by atmospheric pressure
and did work on the pump. The condensed water in the cylinder was
expelled through an escapement valve by the next entry of steam. This
engine used steam having pressure but little, if any, above that of the
atmosphere.
[Pg 16]
closed tank, flowed in a continuous stream against the vanes of a water
wheel. When the steam in the displacement chamber had expanded, it was
exhausted to the atmosphere through a valve instead of being condensed.
The engine was, in fact, a non-condensing, single action steam pump with
the steam and pump cylinders in one. A curious feature of this engine was a
heater placed in the diaphragm. This was a mass of heated metal for the
purpose of keeping the steam dry or preventing condensation during
expansion. This device might be called the first superheater.
Among the various inventions attributed to Papin was a boiler with an
internal fire box, the earliest record of such construction.
While Papin had neglected his earlier suggestion of a steam and piston
engine to work on Savery’s ideas, Thomas Newcomen, with his assistant,
John Cawley, put into practical form Papin’s suggestion of 1690. Steam
admitted from the boiler to a cylinder raised a piston by its expansion,
assisted by a counter-weight on the other end of a beam actuated by the
piston. The steam valve was then shut and the steam condensed by a jet of
cold water. The piston was then forced downward by atmospheric pressure
and did work on the pump. The condensed water in the cylinder was
expelled through an escapement valve by the next entry of steam. This
engine used steam having pressure but little, if any, above that of the
atmosphere.
[Pg 16]
Page 24
Two Units of 8128 Horse Power of Babcock & Wilcox Boilers and
Superheaters at the Fisk Street Station of the Commonwealth Edison
Co., Chicago, Ill., 50,400 Horse Power being Installed in this Station.
The Commonwealth Edison Co. Operates in its Various Stations a Total
of 86,000 Horse Power of Babcock & Wilcox Boilers, all Fitted with
Babcock & Wilcox Superheaters and Equipped with Babcock & Wilcox
Chain Grate Stokers
[Pg 17] In 1711, this engine was introduced into mines for pumping purposes.
Whether its action was originally automatic or whether dependent upon the
hand operation of the valves is a question of doubt. The story commonly
believed is that a boy, Humphrey Potter, in 1713, whose duty it was to open
and shut such valves of an engine he attended, by suitable cords and catches
attached to the beam, caused the engine to automatically manipulate these
valves. This device was simplified in 1718 by Henry Beighton, who
suspended from the bottom, a rod called the plug-tree, which actuated the
valve by tappets. By 1725, this engine was in common use in the collieries
and was changed but little for a matter of sixty or seventy years. Compared
with Savery’s engine, from the aspect of a pumping engine, Newcomen’s
was a distinct advance, in that the pressure in the pumps was in no manner
Superheaters at the Fisk Street Station of the Commonwealth Edison
Co., Chicago, Ill., 50,400 Horse Power being Installed in this Station.
The Commonwealth Edison Co. Operates in its Various Stations a Total
of 86,000 Horse Power of Babcock & Wilcox Boilers, all Fitted with
Babcock & Wilcox Superheaters and Equipped with Babcock & Wilcox
Chain Grate Stokers
[Pg 17] In 1711, this engine was introduced into mines for pumping purposes.
Whether its action was originally automatic or whether dependent upon the
hand operation of the valves is a question of doubt. The story commonly
believed is that a boy, Humphrey Potter, in 1713, whose duty it was to open
and shut such valves of an engine he attended, by suitable cords and catches
attached to the beam, caused the engine to automatically manipulate these
valves. This device was simplified in 1718 by Henry Beighton, who
suspended from the bottom, a rod called the plug-tree, which actuated the
valve by tappets. By 1725, this engine was in common use in the collieries
and was changed but little for a matter of sixty or seventy years. Compared
with Savery’s engine, from the aspect of a pumping engine, Newcomen’s
was a distinct advance, in that the pressure in the pumps was in no manner
Page 25
dependent upon the steam pressure. In common with Savery’s engine, the
losses from the alternate heating and cooling of the steam cylinder were
enormous. Though obviously this engine might have been modified to serve
many purposes, its use seems to have been limited almost entirely to the
pumping of water.
The rivalry between Savery and Papin appears to have stimulated attention
to the question of fuel saving. Dr. John Allen, in 1730, called attention to the
fact that owing to the short length of time of the contact between the gases
and the heating surfaces of the boiler, nearly half of the heat of the fire was
lost. With a view to overcoming this loss at least partially, he used an
internal furnace with a smoke flue winding through the water in the form of
a worm in a still. In order that the length of passage of the gases might not
act as a damper on the fire, Dr. Allen recommended the use of a pair of
bellows for forcing the sluggish vapor through the flue. This is probably the
first suggested use of forced draft. In forming an estimate of the quantity of
fuel lost up the stack, Dr. Allen probably made the first boiler test.
Toward the end of the period of use of Newcomen’s atmospheric engine,
John Smeaton, who, about 1770, built and installed a number of large
engines of this type, greatly improved the design in its mechanical details.
The improvement in boiler and engine design of Smeaton, Newcomen and
their contemporaries, were followed by those of the great engineer, James
Watt, an instrument maker of Glasgow. In 1763, while repairing a model of
Newcomen’s engine, he was impressed by the great waste of steam to which
the alternating cooling and heating of the engine gave rise. His remedy was
the maintaining of the cylinder as hot as the entering steam and with this in
view he added a vessel separate from the cylinder, into which the steam
should pass from the cylinder and be there condensed either by the
application of cold water outside or by a jet from within. To preserve a
vacuum in his condenser, he added an air pump which should serve to
remove the water of condensation and air brought in with the injection water
or due to leakage. As the cylinder no longer acted as a condenser, he could
maintain it at a high temperature by covering it with non-conducting
material and, in particular, by the use of a steam jacket. Further and with the
same object in view, he covered the top of the cylinder and introduced steam
above the piston to do the work previously accomplished by atmospheric
losses from the alternate heating and cooling of the steam cylinder were
enormous. Though obviously this engine might have been modified to serve
many purposes, its use seems to have been limited almost entirely to the
pumping of water.
The rivalry between Savery and Papin appears to have stimulated attention
to the question of fuel saving. Dr. John Allen, in 1730, called attention to the
fact that owing to the short length of time of the contact between the gases
and the heating surfaces of the boiler, nearly half of the heat of the fire was
lost. With a view to overcoming this loss at least partially, he used an
internal furnace with a smoke flue winding through the water in the form of
a worm in a still. In order that the length of passage of the gases might not
act as a damper on the fire, Dr. Allen recommended the use of a pair of
bellows for forcing the sluggish vapor through the flue. This is probably the
first suggested use of forced draft. In forming an estimate of the quantity of
fuel lost up the stack, Dr. Allen probably made the first boiler test.
Toward the end of the period of use of Newcomen’s atmospheric engine,
John Smeaton, who, about 1770, built and installed a number of large
engines of this type, greatly improved the design in its mechanical details.
The improvement in boiler and engine design of Smeaton, Newcomen and
their contemporaries, were followed by those of the great engineer, James
Watt, an instrument maker of Glasgow. In 1763, while repairing a model of
Newcomen’s engine, he was impressed by the great waste of steam to which
the alternating cooling and heating of the engine gave rise. His remedy was
the maintaining of the cylinder as hot as the entering steam and with this in
view he added a vessel separate from the cylinder, into which the steam
should pass from the cylinder and be there condensed either by the
application of cold water outside or by a jet from within. To preserve a
vacuum in his condenser, he added an air pump which should serve to
remove the water of condensation and air brought in with the injection water
or due to leakage. As the cylinder no longer acted as a condenser, he could
maintain it at a high temperature by covering it with non-conducting
material and, in particular, by the use of a steam jacket. Further and with the
same object in view, he covered the top of the cylinder and introduced steam
above the piston to do the work previously accomplished by atmospheric
Page 26
pressure. After several trials with an experimental apparatus based on these
ideas, Watt patented his improvements in 1769. Aside from their historical
importance, Watt’s improvements, as described in his specification, are to
this day a [Pg 18]
[Pg 19] statement of the principles which guide the scientific development of
the steam engine. His words are:
Erie County Electric Co., Erie, Pa., Operating 3082 Horse Power of
Babcock & Wilcox Boilers and Superheaters, Equipped with Babcock &
Wilcox Chain Grate Stokers
ideas, Watt patented his improvements in 1769. Aside from their historical
importance, Watt’s improvements, as described in his specification, are to
this day a [Pg 18]
[Pg 19] statement of the principles which guide the scientific development of
the steam engine. His words are:
Erie County Electric Co., Erie, Pa., Operating 3082 Horse Power of
Babcock & Wilcox Boilers and Superheaters, Equipped with Babcock &
Wilcox Chain Grate Stokers
Page 27
“My method of lessening the consumption of steam, and consequently
fuel, in fire engines, consists of the following principles:
“First, That vessel in which the powers of steam are to be employed to
work the engine, which is called the cylinder in common fire engines,
and which I call the steam vessel, must, during the whole time the
engine is at work, be kept as hot as the steam that enters it; first, by
enclosing it in a case of wood, or any other materials that transmit heat
slowly; secondly, by surrounding it with steam or other heated bodies;
and, thirdly, by suffering neither water nor any other substance colder
than the steam to enter or touch it during that time.
“Secondly, In engines that are to be worked wholly or partially by
condensation of steam, the steam is to be condensed in vessels distinct
from the steam vessels or cylinders, although occasionally
communicating with them; these vessels I call condensers; and, whilst
the engines are working, these condensers ought at least to be kept as
cold as the air in the neighborhood of the engines, by application of
water or other cold bodies.
“Thirdly, Whatever air or other elastic vapor is not condensed by the
cold of the condenser, and may impede the working of the engine, is to
be drawn out of the steam vessels or condensers by means of pumps,
wrought by the engines themselves, or otherwise.
“Fourthly, I intend in many cases to employ the expansive force of
steam to press on the pistons, or whatever may be used instead of them,
in the same manner in which the pressure of the atmosphere is now
employed in common fire engines. In cases where cold water cannot be
had in plenty, the engines may be wrought by this force of steam only,
by discharging the steam into the air after it has done its office….
“Sixthly, I intend in some cases to apply a degree of cold not capable of
reducing the steam to water, but of contracting it considerably, so that
the engines shall be worked by the alternate expansion and contraction
of the steam.
fuel, in fire engines, consists of the following principles:
“First, That vessel in which the powers of steam are to be employed to
work the engine, which is called the cylinder in common fire engines,
and which I call the steam vessel, must, during the whole time the
engine is at work, be kept as hot as the steam that enters it; first, by
enclosing it in a case of wood, or any other materials that transmit heat
slowly; secondly, by surrounding it with steam or other heated bodies;
and, thirdly, by suffering neither water nor any other substance colder
than the steam to enter or touch it during that time.
“Secondly, In engines that are to be worked wholly or partially by
condensation of steam, the steam is to be condensed in vessels distinct
from the steam vessels or cylinders, although occasionally
communicating with them; these vessels I call condensers; and, whilst
the engines are working, these condensers ought at least to be kept as
cold as the air in the neighborhood of the engines, by application of
water or other cold bodies.
“Thirdly, Whatever air or other elastic vapor is not condensed by the
cold of the condenser, and may impede the working of the engine, is to
be drawn out of the steam vessels or condensers by means of pumps,
wrought by the engines themselves, or otherwise.
“Fourthly, I intend in many cases to employ the expansive force of
steam to press on the pistons, or whatever may be used instead of them,
in the same manner in which the pressure of the atmosphere is now
employed in common fire engines. In cases where cold water cannot be
had in plenty, the engines may be wrought by this force of steam only,
by discharging the steam into the air after it has done its office….
“Sixthly, I intend in some cases to apply a degree of cold not capable of
reducing the steam to water, but of contracting it considerably, so that
the engines shall be worked by the alternate expansion and contraction
of the steam.
Page 28
“Lastly, Instead of using water to render the pistons and other parts of
the engine air and steam tight, I employ oils, wax, resinous bodies, fat
of animals, quick-silver and other metals in their fluid state.”
The fifth claim was for a rotary engine, and need not be quoted here.
The early efforts of Watt are typical of those of the poor inventor struggling
with insufficient resources to gain recognition and it was not until he became
associated with the wealthy manufacturer, Mattheu Boulton of Birmingham,
that he met with the success upon which his present fame is based. In
partnership with Boulton, the business of the manufacture and the sale of his
engines were highly successful in spite of vigorous attacks on the validity of
his patents.
Though the fourth claim of Watt’s patent describes a non-condensing engine
which would require high pressures, his aversion to such practice was
strong. Notwithstanding his entire knowledge of the advantages through
added expansion under high pressure, he continued to use pressures not
above 7 pounds per square inch above the atmosphere. To overcome such
pressures, his boilers were fed through a stand-pipe of sufficient height to
have the column of water offset the pressure within the boiler. Watt’s attitude
toward high pressure made his influence felt long after his patents had
expired.
[Pg 20]
the engine air and steam tight, I employ oils, wax, resinous bodies, fat
of animals, quick-silver and other metals in their fluid state.”
The fifth claim was for a rotary engine, and need not be quoted here.
The early efforts of Watt are typical of those of the poor inventor struggling
with insufficient resources to gain recognition and it was not until he became
associated with the wealthy manufacturer, Mattheu Boulton of Birmingham,
that he met with the success upon which his present fame is based. In
partnership with Boulton, the business of the manufacture and the sale of his
engines were highly successful in spite of vigorous attacks on the validity of
his patents.
Though the fourth claim of Watt’s patent describes a non-condensing engine
which would require high pressures, his aversion to such practice was
strong. Notwithstanding his entire knowledge of the advantages through
added expansion under high pressure, he continued to use pressures not
above 7 pounds per square inch above the atmosphere. To overcome such
pressures, his boilers were fed through a stand-pipe of sufficient height to
have the column of water offset the pressure within the boiler. Watt’s attitude
toward high pressure made his influence felt long after his patents had
expired.
[Pg 20]
Page 29
Portion of 9600 Horse-power Installation of Babcock & Wilcox Boilers
and Superheaters, Equipped with Babcock & Wilcox Chain Grate
Stokers at the Blue Island, Ill., Plant of the Public Service Co. of
Northern Illinois. This Company Operates 14,580 Horse Power of
Babcock & Wilcox Boilers and Superheaters in its Various Stations
[Pg 21] In 1782, Watt patented two other features which he had invented as
early as 1769. These were the double acting engine, that is, the use of steam
on both sides of the piston and the use of steam expansively, that is, the
shutting off of steam from the cylinder when the piston had made but a
portion of its stroke, the power for the completion of the stroke being
supplied by the expansive force of the steam already admitted.
He further added a throttle valve for the regulation of steam admission,
invented the automatic governor and the steam indicator, a mercury steam
gauge and a glass water column.
It has been the object of this brief history of the early developments in the
use of steam to cover such developments only through the time of James
Watt. The progress of the steam engine from this time through the stages of
higher pressures, combining of cylinders, the application of steam vehicles
and Superheaters, Equipped with Babcock & Wilcox Chain Grate
Stokers at the Blue Island, Ill., Plant of the Public Service Co. of
Northern Illinois. This Company Operates 14,580 Horse Power of
Babcock & Wilcox Boilers and Superheaters in its Various Stations
[Pg 21] In 1782, Watt patented two other features which he had invented as
early as 1769. These were the double acting engine, that is, the use of steam
on both sides of the piston and the use of steam expansively, that is, the
shutting off of steam from the cylinder when the piston had made but a
portion of its stroke, the power for the completion of the stroke being
supplied by the expansive force of the steam already admitted.
He further added a throttle valve for the regulation of steam admission,
invented the automatic governor and the steam indicator, a mercury steam
gauge and a glass water column.
It has been the object of this brief history of the early developments in the
use of steam to cover such developments only through the time of James
Watt. The progress of the steam engine from this time through the stages of
higher pressures, combining of cylinders, the application of steam vehicles
Page 30
and steamboats, the adding of third and fourth cylinders, to the invention of
the turbine with its development and the accompanying development of the
reciprocating engine to hold its place, is one long attribute to the inventive
genius of man.
While little is said in the biographies of Watt as to the improvement of steam
boilers, all the evidence indicates that Boulton and Watt introduced the first
“wagon boiler”, so called because of its shape. In 1785, Watt took out a
number of patents for variations in furnace construction, many of which
contain the basic principles of some of the modern smoke preventing
furnaces. Until the early part of the nineteenth century, the low steam
pressures used caused but little attention to be given to the form of the boiler
operated in connection with the engines above described. About 1800,
Richard Trevithick, in England, and Oliver Evans, in America, introduced
non-condensing, and for that time, high pressure steam engines. To the
initiative of Evans may be attributed the general use of high pressure steam
in the United States, a feature which for many years distinguished American
from European practice. The demand for light weight and economy of space
following the beginning of steam navigation and the invention of the
locomotive required boilers designed and constructed to withstand heavier
pressures and forced the adoption of the cylindrical form of boiler. There are
in use to-day many examples of every step in the development of steam
boilers from the first plain cylindrical boiler to the most modern type of
multi-tubular locomotive boiler, which stands as the highest type of fire-tube
boiler construction.
The early attempts to utilize water-tube boilers were few. A brief history of
the development of the boilers, in which this principle was employed, is
given in the following chapter. From this history it will be clearly indicated
that the first commercially successful utilization of water tubes in a steam
generator is properly attributed to George H. Babcock and Stephen Wilcox.
[Pg 22]
the turbine with its development and the accompanying development of the
reciprocating engine to hold its place, is one long attribute to the inventive
genius of man.
While little is said in the biographies of Watt as to the improvement of steam
boilers, all the evidence indicates that Boulton and Watt introduced the first
“wagon boiler”, so called because of its shape. In 1785, Watt took out a
number of patents for variations in furnace construction, many of which
contain the basic principles of some of the modern smoke preventing
furnaces. Until the early part of the nineteenth century, the low steam
pressures used caused but little attention to be given to the form of the boiler
operated in connection with the engines above described. About 1800,
Richard Trevithick, in England, and Oliver Evans, in America, introduced
non-condensing, and for that time, high pressure steam engines. To the
initiative of Evans may be attributed the general use of high pressure steam
in the United States, a feature which for many years distinguished American
from European practice. The demand for light weight and economy of space
following the beginning of steam navigation and the invention of the
locomotive required boilers designed and constructed to withstand heavier
pressures and forced the adoption of the cylindrical form of boiler. There are
in use to-day many examples of every step in the development of steam
boilers from the first plain cylindrical boiler to the most modern type of
multi-tubular locomotive boiler, which stands as the highest type of fire-tube
boiler construction.
The early attempts to utilize water-tube boilers were few. A brief history of
the development of the boilers, in which this principle was employed, is
given in the following chapter. From this history it will be clearly indicated
that the first commercially successful utilization of water tubes in a steam
generator is properly attributed to George H. Babcock and Stephen Wilcox.
[Pg 22]
Page 31
Copyright by Underwood & Underwood
Woolworth Building, New York City, Operating 2454 Horse Power of
Babcock & Wilcox Boilers
Woolworth Building, New York City, Operating 2454 Horse Power of
Babcock & Wilcox Boilers
Page 32
[Pg 23]
Page 33
BRIEF HISTORY OF WATER-TUBE
BOILERS[1]
As stated in the previous chapter, the first water-tube boiler
was built by John Blakey and was patented by him in
1766. Several tubes alternately inclined at opposite angles
were arranged in the furnaces, the adjacent tube ends being
connected by small pipes. The first successful user of
water-tube boilers, however, was James Rumsey, an
American inventor, celebrated for his early experiments in
steam navigation, and it is he who may be truly classed as
the originator of the water-tube boiler. In 1788 he patented,
in England, several forms of boilers, some of which were
of the water-tube type. One had a fire box with flat top and Blakey, 1766
sides, with horizontal tubes across the fire box connecting
the water spaces. Another had a cylindrical fire box
surrounded by an annular water space and a coiled tube was placed within
the box connecting at its two ends with the water space. This was the first of
the “coil boilers”. Another form in the same patent was the vertical tubular
boiler, practically as made at the present time.
The first boiler made of a
combination of small tubes,
connected at one end to a reservoir,
was the invention of another
American, John Stevens, in 1804.
This boiler was actually employed
to generate steam for running a
steamboat on the Hudson River, but
John Stevens, 1804 like all the “porcupine” boilers, of
which type it was the first, it did not
have the elements of a continued
success.
BOILERS[1]
As stated in the previous chapter, the first water-tube boiler
was built by John Blakey and was patented by him in
1766. Several tubes alternately inclined at opposite angles
were arranged in the furnaces, the adjacent tube ends being
connected by small pipes. The first successful user of
water-tube boilers, however, was James Rumsey, an
American inventor, celebrated for his early experiments in
steam navigation, and it is he who may be truly classed as
the originator of the water-tube boiler. In 1788 he patented,
in England, several forms of boilers, some of which were
of the water-tube type. One had a fire box with flat top and Blakey, 1766
sides, with horizontal tubes across the fire box connecting
the water spaces. Another had a cylindrical fire box
surrounded by an annular water space and a coiled tube was placed within
the box connecting at its two ends with the water space. This was the first of
the “coil boilers”. Another form in the same patent was the vertical tubular
boiler, practically as made at the present time.
The first boiler made of a
combination of small tubes,
connected at one end to a reservoir,
was the invention of another
American, John Stevens, in 1804.
This boiler was actually employed
to generate steam for running a
steamboat on the Hudson River, but
John Stevens, 1804 like all the “porcupine” boilers, of
which type it was the first, it did not
have the elements of a continued
success.
Page 34
Another form of water tube was patented in
1805 by John Cox Stevens, a son of John
Stevens. This boiler consisted of twenty
vertical tubes, 1¼ inches internal diameter and
40½ inches long, arranged in a circle, the
outside diameter of which was approximately
12 inches, connecting a water chamber at the
bottom with a steam chamber at the top. The
steam and water chambers were annular spaces
of small cross section and contained
approximately 33 cubic inches. The illustration
shows the cap of the steam chamber secured by
bolts. The steam outlet pipe “A” is a pipe of John Cox Stevens, 1805
one inch diameter, the water entering through a
similar aperture at the bottom. One of these
boilers was for a long time at the Stevens Institute of Technology at
Hoboken, and is now in the Smithsonian Institute at Washington.
About the same time, Jacob Woolf built a boiler of large horizontal tubes,
extending across the furnace and connected at the ends to a longitudinal
drum above. The first purely sectional [Pg 24] water-tube boiler was built by
Julius Griffith, in 1821. In this boiler, a number of horizontal water tubes
were connected to vertical side pipes, the side pipes were connected to
horizontal gathering pipes, and these latter in turn to a steam drum.
In 1822, Jacob Perkins
constructed a flash boiler
for carrying what was then
considered a high pressure.
A number of cast-iron bars
having 1½ inches annular
holes through them and
connected at their outer
ends by a series of bent
pipes, outside of the furnace
walls, were arranged in
three tiers over the fire. The
water was fed slowly to the
1805 by John Cox Stevens, a son of John
Stevens. This boiler consisted of twenty
vertical tubes, 1¼ inches internal diameter and
40½ inches long, arranged in a circle, the
outside diameter of which was approximately
12 inches, connecting a water chamber at the
bottom with a steam chamber at the top. The
steam and water chambers were annular spaces
of small cross section and contained
approximately 33 cubic inches. The illustration
shows the cap of the steam chamber secured by
bolts. The steam outlet pipe “A” is a pipe of John Cox Stevens, 1805
one inch diameter, the water entering through a
similar aperture at the bottom. One of these
boilers was for a long time at the Stevens Institute of Technology at
Hoboken, and is now in the Smithsonian Institute at Washington.
About the same time, Jacob Woolf built a boiler of large horizontal tubes,
extending across the furnace and connected at the ends to a longitudinal
drum above. The first purely sectional [Pg 24] water-tube boiler was built by
Julius Griffith, in 1821. In this boiler, a number of horizontal water tubes
were connected to vertical side pipes, the side pipes were connected to
horizontal gathering pipes, and these latter in turn to a steam drum.
In 1822, Jacob Perkins
constructed a flash boiler
for carrying what was then
considered a high pressure.
A number of cast-iron bars
having 1½ inches annular
holes through them and
connected at their outer
ends by a series of bent
pipes, outside of the furnace
walls, were arranged in
three tiers over the fire. The
water was fed slowly to the
Page 35
Joseph Eve, 1825 upper tier by a force pump
and steam in the
superheated state was
discharged to the lower tiers into a chamber from which it was taken to the
engine.
The first sectional water-tube boiler, with a well-defined circulation, was
built by Joseph Eve, in 1825. The sections were composed of small tubes
with a slight double curve, but being practically vertical, fixed in horizontal
headers, which headers were in turn connected to a steam space above and a
water space below formed of larger pipes. The steam and water spaces were
connected by outside pipes to secure a circulation of the water up through
the sections and down through the external pipes. In the same year, John
M’Curdy of New York, built a “Duplex Steam Generator” of “tubes of
wrought or cast iron or other material” arranged in several horizontal rows,
connected together alternately at the front and rear by return bends. In the
tubes below the water line were placed interior circular vessels closed at the
ends in order to expose a thin sheet of water to the action of the fire.
In 1826, Goldsworthy Gurney
built a number of boilers,
which he used on his steam
carriages. A number of small
tubes were bent into the shape
of a “U” laid [Pg 25] sidewise
and the ends were connected
with larger horizontal pipes.
These were connected by
vertical pipes to permit of
circulation and also to a
vertical cylinder which served Gurney, 1826
as a steam and water reservoir.
In 1828, Paul Steenstrup made
the first shell boiler with vertical water tubes in the large flues, similar to the
boiler known as the “Martin” and suggesting the “Galloway”.
The first water-tube boiler having fire tubes within water tubes was built in
1830, by Summers & Ogle. Horizontal connections at the top and bottom
and steam in the
superheated state was
discharged to the lower tiers into a chamber from which it was taken to the
engine.
The first sectional water-tube boiler, with a well-defined circulation, was
built by Joseph Eve, in 1825. The sections were composed of small tubes
with a slight double curve, but being practically vertical, fixed in horizontal
headers, which headers were in turn connected to a steam space above and a
water space below formed of larger pipes. The steam and water spaces were
connected by outside pipes to secure a circulation of the water up through
the sections and down through the external pipes. In the same year, John
M’Curdy of New York, built a “Duplex Steam Generator” of “tubes of
wrought or cast iron or other material” arranged in several horizontal rows,
connected together alternately at the front and rear by return bends. In the
tubes below the water line were placed interior circular vessels closed at the
ends in order to expose a thin sheet of water to the action of the fire.
In 1826, Goldsworthy Gurney
built a number of boilers,
which he used on his steam
carriages. A number of small
tubes were bent into the shape
of a “U” laid [Pg 25] sidewise
and the ends were connected
with larger horizontal pipes.
These were connected by
vertical pipes to permit of
circulation and also to a
vertical cylinder which served Gurney, 1826
as a steam and water reservoir.
In 1828, Paul Steenstrup made
the first shell boiler with vertical water tubes in the large flues, similar to the
boiler known as the “Martin” and suggesting the “Galloway”.
The first water-tube boiler having fire tubes within water tubes was built in
1830, by Summers & Ogle. Horizontal connections at the top and bottom
Page 36
were connected by a series of vertical water tubes, through which were fire
tubes extending through the horizontal connections, the fire tubes being held
in place by nuts, which also served to make the joint.
Stephen Wilcox, in 1856, was the
first to use inclined water tubes
connecting water spaces at the front
and rear with a steam space above.
The first to make such inclined
tubes into a sectional form was
Twibill, in 1865. He used wrought-
iron tubes connected at the front and
Stephen Wilcox, 1856 rear with standpipes through
intermediate connections. These
standpipes carried the system to a
horizontal cross drum at the top, the entrained water being carried to the rear.
Clarke, Moore, McDowell, Alban and others worked on the problem of
constructing water-tube boilers, but because of difficulties of construction
involved, met with no practical success.
It may be asked why
water-tube boilers did
not come into more
general use at an early
date, that is, why the
number of water-tube
boilers built was so
small in comparison to
the number of shell
boilers. The reason for
this is found in the
difficulties involved in
Twibill, 1865
the design and
construction of water-
tube boilers, which
design and construction required a high class of engineering and
workmanship, while the plain cylindrical boiler is comparatively easy to
tubes extending through the horizontal connections, the fire tubes being held
in place by nuts, which also served to make the joint.
Stephen Wilcox, in 1856, was the
first to use inclined water tubes
connecting water spaces at the front
and rear with a steam space above.
The first to make such inclined
tubes into a sectional form was
Twibill, in 1865. He used wrought-
iron tubes connected at the front and
Stephen Wilcox, 1856 rear with standpipes through
intermediate connections. These
standpipes carried the system to a
horizontal cross drum at the top, the entrained water being carried to the rear.
Clarke, Moore, McDowell, Alban and others worked on the problem of
constructing water-tube boilers, but because of difficulties of construction
involved, met with no practical success.
It may be asked why
water-tube boilers did
not come into more
general use at an early
date, that is, why the
number of water-tube
boilers built was so
small in comparison to
the number of shell
boilers. The reason for
this is found in the
difficulties involved in
Twibill, 1865
the design and
construction of water-
tube boilers, which
design and construction required a high class of engineering and
workmanship, while the plain cylindrical boiler is comparatively easy to
Page 37
build. The greater skill required to make a water-tube boiler successful is
readily shown in the great number of failures in the attempts to make them.
[Pg 26]
Partial View of 7000 Horse-power Installation of Babcock & Wilcox
Boilers at the Philadelphia, Pa., Plant of the Baldwin Locomotive
Works. This Company Operates in its Various Plants a Total of 9280
Horse Power of Babcock & Wilcox Boilers
FOOTNOTES
[1] See discussion by George H. Babcock, of Stirling’s paper on “Water-tube and
Shell Boilers”, in Transactions, American Society of Mechanical Engineers,
Volume VI., Page 601.
readily shown in the great number of failures in the attempts to make them.
[Pg 26]
Partial View of 7000 Horse-power Installation of Babcock & Wilcox
Boilers at the Philadelphia, Pa., Plant of the Baldwin Locomotive
Works. This Company Operates in its Various Plants a Total of 9280
Horse Power of Babcock & Wilcox Boilers
FOOTNOTES
[1] See discussion by George H. Babcock, of Stirling’s paper on “Water-tube and
Shell Boilers”, in Transactions, American Society of Mechanical Engineers,
Volume VI., Page 601.
Page 38
[Pg 27]
Page 39
REQUIREMENTS OF STEAM BOILERS
Since the first appearance in “Steam” of the following “Requirements of a
Perfect Steam Boiler”, the list has been copied many times either word for
word or clothed in different language and applied to some specific type of
boiler design or construction. In most cases, although full compliance with
one or more of the requirements was structurally impossible, the reader was
left to infer that the boiler under consideration possessed all the desirable
features. It is noteworthy that this list of requirements, as prepared by
George H. Babcock and Stephen Wilcox, in 1875, represents the best
practice of to-day. Moreover, coupled with the boiler itself, which is used in
the largest and most important steam generating plants throughout the world,
the list forms a fitting monument to the foresight and genius of the inventors.
REQUIREMENTS OF A PERFECT STEAM BOILER
1st. Proper workmanship and simple construction, using materials which
experience has shown to be the best, thus avoiding the necessity of early
repairs.
2nd. A mud drum to receive all impurities deposited from the water, and so
placed as to be removed from the action of the fire.
3rd. A steam and water capacity sufficient to prevent any fluctuation in
steam pressure or water level.
4th. A water surface for the disengagement of the steam from the water, of
sufficient extent to prevent foaming.
5th. A constant and thorough circulation of water throughout the boiler, so as
to maintain all parts at the same temperature.
6th. The water space divided into sections so arranged that, should any
section fail, no general explosion can occur and the destructive effects will
Since the first appearance in “Steam” of the following “Requirements of a
Perfect Steam Boiler”, the list has been copied many times either word for
word or clothed in different language and applied to some specific type of
boiler design or construction. In most cases, although full compliance with
one or more of the requirements was structurally impossible, the reader was
left to infer that the boiler under consideration possessed all the desirable
features. It is noteworthy that this list of requirements, as prepared by
George H. Babcock and Stephen Wilcox, in 1875, represents the best
practice of to-day. Moreover, coupled with the boiler itself, which is used in
the largest and most important steam generating plants throughout the world,
the list forms a fitting monument to the foresight and genius of the inventors.
REQUIREMENTS OF A PERFECT STEAM BOILER
1st. Proper workmanship and simple construction, using materials which
experience has shown to be the best, thus avoiding the necessity of early
repairs.
2nd. A mud drum to receive all impurities deposited from the water, and so
placed as to be removed from the action of the fire.
3rd. A steam and water capacity sufficient to prevent any fluctuation in
steam pressure or water level.
4th. A water surface for the disengagement of the steam from the water, of
sufficient extent to prevent foaming.
5th. A constant and thorough circulation of water throughout the boiler, so as
to maintain all parts at the same temperature.
6th. The water space divided into sections so arranged that, should any
section fail, no general explosion can occur and the destructive effects will
Page 40
be confined to the escape of the contents. Large and free passages between
the different sections to equalize the water line and pressure in all.
7th. A great excess of strength over any legitimate strain, the boiler being so
constructed as to be free from strains due to unequal expansion, and, if
possible, to avoid joints exposed to the direct action of the fire.
8th. A combustion chamber so arranged that the combustion of the gases
started in the furnace may be completed before the gases escape to the
chimney.
9th. The heating surface as nearly as possible at right angles to the currents
of heated gases, so as to break up the currents and extract the entire available
heat from the gases.
10th. All parts readily accessible for cleaning and repairs. This is a point of
the greatest importance as regards safety and economy.
11th. Proportioned for the work to be done, and capable of working to its full
rated capacity with the highest economy.
12th. Equipped with the very best gauges, safety valves and other fixtures.
[Pg 28]
The exhaustive study made of each one of these requirements is shown by
the following extract from a lecture delivered by Mr. Geo. H. Babcock at
Cornell University in 1890 upon the subject:
THE CIRCULATION OF WATER IN STEAM BOILERS
You have all noticed a kettle of water boiling over the fire, the fluid rising
somewhat tumultuously around the edges of the vessel, and tumbling toward
the center, where it descends. Similar currents are in action while the water
is simply being heated, but they are not perceptible unless there are floating
particles in the liquid. These currents are caused by the joint action of the
added temperature and two or more qualities which the water possesses.
the different sections to equalize the water line and pressure in all.
7th. A great excess of strength over any legitimate strain, the boiler being so
constructed as to be free from strains due to unequal expansion, and, if
possible, to avoid joints exposed to the direct action of the fire.
8th. A combustion chamber so arranged that the combustion of the gases
started in the furnace may be completed before the gases escape to the
chimney.
9th. The heating surface as nearly as possible at right angles to the currents
of heated gases, so as to break up the currents and extract the entire available
heat from the gases.
10th. All parts readily accessible for cleaning and repairs. This is a point of
the greatest importance as regards safety and economy.
11th. Proportioned for the work to be done, and capable of working to its full
rated capacity with the highest economy.
12th. Equipped with the very best gauges, safety valves and other fixtures.
[Pg 28]
The exhaustive study made of each one of these requirements is shown by
the following extract from a lecture delivered by Mr. Geo. H. Babcock at
Cornell University in 1890 upon the subject:
THE CIRCULATION OF WATER IN STEAM BOILERS
You have all noticed a kettle of water boiling over the fire, the fluid rising
somewhat tumultuously around the edges of the vessel, and tumbling toward
the center, where it descends. Similar currents are in action while the water
is simply being heated, but they are not perceptible unless there are floating
particles in the liquid. These currents are caused by the joint action of the
added temperature and two or more qualities which the water possesses.
Page 41
1st. Water, in common with most other substances, expands when heated; a
statement, however, strictly true only when referred to a temperature above
39 degrees F. or 4 degrees C., but as in the making of steam we rarely have
to do with temperatures so low as that, we may, for our present purposes,
ignore that exception.
2nd. Water is practically a non-conductor of heat, though not entirely so. If
ice-cold water was kept boiling at the surface the heat would not penetrate
sufficiently to begin melting ice at a depth of 3 inches in less than about two
hours. As, therefore, the heated water cannot impart its heat to its
neighboring particles, it remains expanded and rises by its levity, while
colder portions come to be heated in turn, thus setting up currents in the
fluid.
Now, when all the water has been heated to the
boiling point corresponding to the pressure to which it
is subjected, each added unit of heat converts a
portion, about 7 grains in weight, into vapor, greatly
increasing its volume; and the mingled steam and
water rises more rapidly still, producing ebullition
such as we have noticed in the kettle. So long as the
quantity of heat added to the contents of the kettle
continues practically constant, the conditions remain
Fig. 1 similar to those we noticed at first, a tumultuous
lifting of the water around the edges, flowing toward
the center and thence downward; if, however, the fire
be quickened, the upward currents interfere with the downward and the
kettle boils over (Fig. 1).
If now we put in the kettle a vessel somewhat
smaller (Fig. 2) with a hole in the bottom and
supported at a proper distance from the side so as to
separate the upward from the downward currents,
we can force the fires to a very much greater extent
without causing the kettle to boil over, and when we
place a deflecting plate so as to guide the rising
column toward the center it will be almost
impossible to produce that effect. This is the
statement, however, strictly true only when referred to a temperature above
39 degrees F. or 4 degrees C., but as in the making of steam we rarely have
to do with temperatures so low as that, we may, for our present purposes,
ignore that exception.
2nd. Water is practically a non-conductor of heat, though not entirely so. If
ice-cold water was kept boiling at the surface the heat would not penetrate
sufficiently to begin melting ice at a depth of 3 inches in less than about two
hours. As, therefore, the heated water cannot impart its heat to its
neighboring particles, it remains expanded and rises by its levity, while
colder portions come to be heated in turn, thus setting up currents in the
fluid.
Now, when all the water has been heated to the
boiling point corresponding to the pressure to which it
is subjected, each added unit of heat converts a
portion, about 7 grains in weight, into vapor, greatly
increasing its volume; and the mingled steam and
water rises more rapidly still, producing ebullition
such as we have noticed in the kettle. So long as the
quantity of heat added to the contents of the kettle
continues practically constant, the conditions remain
Fig. 1 similar to those we noticed at first, a tumultuous
lifting of the water around the edges, flowing toward
the center and thence downward; if, however, the fire
be quickened, the upward currents interfere with the downward and the
kettle boils over (Fig. 1).
If now we put in the kettle a vessel somewhat
smaller (Fig. 2) with a hole in the bottom and
supported at a proper distance from the side so as to
separate the upward from the downward currents,
we can force the fires to a very much greater extent
without causing the kettle to boil over, and when we
place a deflecting plate so as to guide the rising
column toward the center it will be almost
impossible to produce that effect. This is the
Page 42
invention of Perkins in 1831 and forms the basis of Fig. 2
very many of the arrangements for producing free
circulation of the water in boilers which have been
made since that time. It consists in dividing the currents so that they will not
interfere each with the other.
[Pg 29]
But what is the object of facilitating the circulation of water in
boilers? Why may we not safely leave this to the unassisted
action of nature as we do in culinary operations? We may, if we
do not care for the three most important aims in steam-boiler
construction, namely, efficiency, durability, and safety, each of
which is more or less dependent upon a proper circulation of
the water. As for efficiency, we have seen one proof in our
kettle. When we provided means to preserve the circulation, we
found that we could carry a hotter fire and boil away the water
Fig. 3 much more rapidly than before. It is the same in a steam boiler.
And we also noticed that when there was nothing but the
unassisted circulation, the rising steam carried away so much
water in the form of foam that the kettle boiled over, but when the currents
were separated and an unimpeded circuit was established, this ceased, and a
much larger supply of steam was delivered in a comparatively dry state.
Thus, circulation increases the efficiency in two ways: it adds to the ability
to take up the heat, and decreases the liability to waste that heat by what is
technically known as priming. There is yet another way in which,
incidentally, circulation increases efficiency of surface, and that is by
preventing in a greater or less degree the formation of deposits thereon. Most
waters contain some impurity which, when the water is evaporated, remains
to incrust the surface of the vessel. This incrustation becomes very serious
sometimes, so much so as to almost entirely prevent the transmission of heat
from the metal to the water. It is said that an incrustation of only one-eighth
inch will cause a loss of 25 per cent in efficiency, and this is probably within
the truth in many cases. Circulation of water will not prevent incrustation
altogether, but it lessens the amount in all waters, and almost entirely so in
some, thus adding greatly to the efficiency of the surface.
very many of the arrangements for producing free
circulation of the water in boilers which have been
made since that time. It consists in dividing the currents so that they will not
interfere each with the other.
[Pg 29]
But what is the object of facilitating the circulation of water in
boilers? Why may we not safely leave this to the unassisted
action of nature as we do in culinary operations? We may, if we
do not care for the three most important aims in steam-boiler
construction, namely, efficiency, durability, and safety, each of
which is more or less dependent upon a proper circulation of
the water. As for efficiency, we have seen one proof in our
kettle. When we provided means to preserve the circulation, we
found that we could carry a hotter fire and boil away the water
Fig. 3 much more rapidly than before. It is the same in a steam boiler.
And we also noticed that when there was nothing but the
unassisted circulation, the rising steam carried away so much
water in the form of foam that the kettle boiled over, but when the currents
were separated and an unimpeded circuit was established, this ceased, and a
much larger supply of steam was delivered in a comparatively dry state.
Thus, circulation increases the efficiency in two ways: it adds to the ability
to take up the heat, and decreases the liability to waste that heat by what is
technically known as priming. There is yet another way in which,
incidentally, circulation increases efficiency of surface, and that is by
preventing in a greater or less degree the formation of deposits thereon. Most
waters contain some impurity which, when the water is evaporated, remains
to incrust the surface of the vessel. This incrustation becomes very serious
sometimes, so much so as to almost entirely prevent the transmission of heat
from the metal to the water. It is said that an incrustation of only one-eighth
inch will cause a loss of 25 per cent in efficiency, and this is probably within
the truth in many cases. Circulation of water will not prevent incrustation
altogether, but it lessens the amount in all waters, and almost entirely so in
some, thus adding greatly to the efficiency of the surface.
Page 43
A second advantage to be obtained through circulation
is durability of the boiler. This it secures mainly by
keeping all parts at a nearly uniform temperature. The
way to secure the greatest freedom from unequal
strains in a boiler is to provide for such a circulation of
the water as will insure the same temperature in all
parts.
3rd. Safety follows in the wake of durability, because a
boiler which is not subject to unequal strains of Fig. 4
expansion and contraction is not only less liable to
ordinary repairs, but also to rupture and disastrous
explosion. By far the most prolific cause of explosions is this same strain
from unequal expansions.
Having thus briefly looked at the advantages of circulation of water in steam
boilers, let us see what are the best means of securing it under the most
efficient conditions We have seen in our kettle that one essential point was
that the currents should be kept from interfering with each other. If we could
look into an ordinary return tubular boiler when steaming, we should see a
curious commotion of currents rushing hither and thither, and shifting
continually as one or the other contending force gained a momentary
mastery. The principal upward currents would be found at the two ends, one
over the fire and the other over the first foot or so of the tubes. Between
these, the downward currents struggle [Pg 30]
[Pg 31] against the rising currents of steam and water. At a sudden demand for
steam, or on the lifting of the safety valve, the pressure being slightly
reduced, the water jumps up in jets at every portion of the surface, being
lifted by the sudden generation of steam throughout the body of water. You
have seen the effect of this sudden generation of steam in the well-known
experiment with a Florence flask, to which a cold application is made while
boiling water under pressure is within. You have also witnessed the geyser-
like action when water is boiled in a test tube held vertically over a lamp
(Fig. 3).
is durability of the boiler. This it secures mainly by
keeping all parts at a nearly uniform temperature. The
way to secure the greatest freedom from unequal
strains in a boiler is to provide for such a circulation of
the water as will insure the same temperature in all
parts.
3rd. Safety follows in the wake of durability, because a
boiler which is not subject to unequal strains of Fig. 4
expansion and contraction is not only less liable to
ordinary repairs, but also to rupture and disastrous
explosion. By far the most prolific cause of explosions is this same strain
from unequal expansions.
Having thus briefly looked at the advantages of circulation of water in steam
boilers, let us see what are the best means of securing it under the most
efficient conditions We have seen in our kettle that one essential point was
that the currents should be kept from interfering with each other. If we could
look into an ordinary return tubular boiler when steaming, we should see a
curious commotion of currents rushing hither and thither, and shifting
continually as one or the other contending force gained a momentary
mastery. The principal upward currents would be found at the two ends, one
over the fire and the other over the first foot or so of the tubes. Between
these, the downward currents struggle [Pg 30]
[Pg 31] against the rising currents of steam and water. At a sudden demand for
steam, or on the lifting of the safety valve, the pressure being slightly
reduced, the water jumps up in jets at every portion of the surface, being
lifted by the sudden generation of steam throughout the body of water. You
have seen the effect of this sudden generation of steam in the well-known
experiment with a Florence flask, to which a cold application is made while
boiling water under pressure is within. You have also witnessed the geyser-
like action when water is boiled in a test tube held vertically over a lamp
(Fig. 3).
Page 44
386 Horse-power Installation of Babcock & Wilcox Boilers at B. F.
Keith’s Theatre, Boston, Mass.
If now we take a U-tube depending from a vessel of
water (Fig. 4) and apply the lamp to one leg a
circulation is at once set up within it, and no such
spasmodic action can be produced. Thus U-tube is the
representative of the true method of circulation within a
water-tube boiler properly constructed. We can, for the
Fig. 5 purpose of securing more heating surface, extend the
heated leg into a long incline (Fig. 5), when we have
the well-known inclined-tube generator. Now, by
adding other tubes, we may further increase the heating
surface (Fig. 6), while it will still be the U-tube in effect and action. In such
a construction the circulation is a function of the difference in density of the
two columns. Its velocity is measured by the well-known Torricellian
formula, V = (2gh)½, or, approximately V = 8(h)½, h being measured in
terms of the lighter fluid. This velocity will increase until the rising column
becomes all steam, but the quantity or weight circulated will attain a
maximum when the density of the mingled steam and water in the rising
Keith’s Theatre, Boston, Mass.
If now we take a U-tube depending from a vessel of
water (Fig. 4) and apply the lamp to one leg a
circulation is at once set up within it, and no such
spasmodic action can be produced. Thus U-tube is the
representative of the true method of circulation within a
water-tube boiler properly constructed. We can, for the
Fig. 5 purpose of securing more heating surface, extend the
heated leg into a long incline (Fig. 5), when we have
the well-known inclined-tube generator. Now, by
adding other tubes, we may further increase the heating
surface (Fig. 6), while it will still be the U-tube in effect and action. In such
a construction the circulation is a function of the difference in density of the
two columns. Its velocity is measured by the well-known Torricellian
formula, V = (2gh)½, or, approximately V = 8(h)½, h being measured in
terms of the lighter fluid. This velocity will increase until the rising column
becomes all steam, but the quantity or weight circulated will attain a
maximum when the density of the mingled steam and water in the rising
Page 45
column becomes one-half that of the solid water in the descending column
which is nearly coincident with the condition of half steam and half water,
the weight of the steam being very slight compared to that of the water.
It becomes easy by this rule to determine the circulation in any given boiler
built on this principle, provided the construction is such as to permit a free
flow of the water. Of course, every bend detracts a little and something is
lost in getting up the velocity, but when the boiler is well arranged and
proportioned these retardations are slight.
Let us take for example one of the 240 horse-
power Babcock & Wilcox boilers here in the
University. The height of the columns may be
taken as 4½ feet, measuring from the surface
of the water to about the center of the bundle
of tubes over the fire, and the head would be
equal to this height at the maximum of
circulation. We should, therefore, have a
velocity of 8(4½)½ = 16.97, say 17 feet per
second. There are in this boiler fourteen Fig. 6
sections, each having a 4-inch tube opening
into the drum, the area of which (inside) is 11
square inches, the fourteen aggregating 154 square inches, or 1.07 square
feet. This multiplied by the velocity, 16.97 feet, gives 18.16 cubic feet
mingled steam and water discharged per second, one-half of which, or 9.08
cubic feet, is steam. Assuming this steam to be at 100 pounds gauge
pressure, it will weigh 0.258 pound per cubic foot. Hence, 2.34 pounds of
steam will be [Pg 32]
[Pg 33] discharged per second, and 8,433 pounds per hour. Dividing this by
30, the number of pounds representing a boiler horse power, we get 281.1
horse power, about 17 per cent, in excess of the rated power of the boiler.
The water at the temperature of steam at 100 pounds pressure weighs 56
pounds per cubic foot, and the steam 0.258 pound, so that the steam forms
but 1⁄218 part of the mixture by weight, and consequently each particle of
water will make 218 circuits before being evaporated when working at this
capacity, and circulating the maximum weight of water through the tubes.
which is nearly coincident with the condition of half steam and half water,
the weight of the steam being very slight compared to that of the water.
It becomes easy by this rule to determine the circulation in any given boiler
built on this principle, provided the construction is such as to permit a free
flow of the water. Of course, every bend detracts a little and something is
lost in getting up the velocity, but when the boiler is well arranged and
proportioned these retardations are slight.
Let us take for example one of the 240 horse-
power Babcock & Wilcox boilers here in the
University. The height of the columns may be
taken as 4½ feet, measuring from the surface
of the water to about the center of the bundle
of tubes over the fire, and the head would be
equal to this height at the maximum of
circulation. We should, therefore, have a
velocity of 8(4½)½ = 16.97, say 17 feet per
second. There are in this boiler fourteen Fig. 6
sections, each having a 4-inch tube opening
into the drum, the area of which (inside) is 11
square inches, the fourteen aggregating 154 square inches, or 1.07 square
feet. This multiplied by the velocity, 16.97 feet, gives 18.16 cubic feet
mingled steam and water discharged per second, one-half of which, or 9.08
cubic feet, is steam. Assuming this steam to be at 100 pounds gauge
pressure, it will weigh 0.258 pound per cubic foot. Hence, 2.34 pounds of
steam will be [Pg 32]
[Pg 33] discharged per second, and 8,433 pounds per hour. Dividing this by
30, the number of pounds representing a boiler horse power, we get 281.1
horse power, about 17 per cent, in excess of the rated power of the boiler.
The water at the temperature of steam at 100 pounds pressure weighs 56
pounds per cubic foot, and the steam 0.258 pound, so that the steam forms
but 1⁄218 part of the mixture by weight, and consequently each particle of
water will make 218 circuits before being evaporated when working at this
capacity, and circulating the maximum weight of water through the tubes.
Page 46
A Portion of 9600 Horse-power Installation of Babcock & Wilcox
Boilers and Superheaters Being Erected at the South Boston, Mass.,
Station of the Boston Elevated Railway Co. This Company Operates in
its Various Stations a Total of 46,400 Horse Power of Babcock & Wilcox
Boilers
It is evident that at the highest possible velocity of exit
from the generating tubes, nothing but steam will be
delivered and there will be no circulation of water
except to supply the place of that evaporated. Let us see
at what rate of steaming this would occur with the
boiler under consideration. We shall have a column of
steam, say 4 feet high on one side and an equal column
of water on the other. Assuming, as before, the steam at
100 pounds and the water at same temperature, we will Fig. 7
have a head of 866 feet of steam and an issuing
velocity of 235.5 feet per second. This multiplied by
1.07 square feet of opening by 3,600 seconds in an hour, and by 0.258 gives
234,043 pounds of steam, which, though only one-eighth the weight of
mingled steam and water delivered at the maximum, gives us 7,801 horse
Boilers and Superheaters Being Erected at the South Boston, Mass.,
Station of the Boston Elevated Railway Co. This Company Operates in
its Various Stations a Total of 46,400 Horse Power of Babcock & Wilcox
Boilers
It is evident that at the highest possible velocity of exit
from the generating tubes, nothing but steam will be
delivered and there will be no circulation of water
except to supply the place of that evaporated. Let us see
at what rate of steaming this would occur with the
boiler under consideration. We shall have a column of
steam, say 4 feet high on one side and an equal column
of water on the other. Assuming, as before, the steam at
100 pounds and the water at same temperature, we will Fig. 7
have a head of 866 feet of steam and an issuing
velocity of 235.5 feet per second. This multiplied by
1.07 square feet of opening by 3,600 seconds in an hour, and by 0.258 gives
234,043 pounds of steam, which, though only one-eighth the weight of
mingled steam and water delivered at the maximum, gives us 7,801 horse
Page 47
power, or 32 times the rated power of the boiler. Of course, this is far beyond
any possibility of attainment, so that it may be set down as certain that this
boiler cannot be forced to a point where there will not be an efficient
circulation of the water. By the same method of calculation it may be shown
that when forced to double its rated power, a point rarely expected to be
reached in practice, about two-thirds the volume of mixture of steam and
water delivered into the drum will be steam, and that the water will make
110 circuits while being evaporated. Also that when worked at only about
one-quarter its rated capacity, one-fifth of the volume will be steam and the
water will make the rounds 870 times before it becomes steam. You will thus
see that in the proportions adopted in this boiler there is provision for perfect
circulation under all the possible conditions of practice.
In designing boilers of this style
it is necessary to guard against
having the uptake at the upper
end of the tubes too large, for if
sufficiently large to allow
downward currents therein, the
whole effect of the rising
column in increasing the
circulation in the tubes is
nullified (Fig. 7). This will
Fig. 8 [Developed to show Circulation] readily be seen if we consider
the uptake very large when the
only head producing circulation
in the tubes will be that due to the inclination of each tube taken by itself.
This objection is only overcome when the uptake is so small as to be entirely
filled with the ascending current of mingled steam and water. It is also
necessary that this uptake should be practically direct, and it should not be
composed of frequent enlargements and [Pg 34]
[Pg 35] contractions. Take, for instance, a boiler well known in Europe, copied
and sold here under another name. It is made up of inclined tubes secured by
pairs into boxes at the ends, which boxes are made to communicate with
each other by return bends opposite the ends of the tubes. These boxes and
return bends form an irregular uptake, whereby the steam is expected to rise
to a reservoir above. You will notice (Fig. 8) that the upward current of
steam and water in the return bend meets and directly antagonizes the
any possibility of attainment, so that it may be set down as certain that this
boiler cannot be forced to a point where there will not be an efficient
circulation of the water. By the same method of calculation it may be shown
that when forced to double its rated power, a point rarely expected to be
reached in practice, about two-thirds the volume of mixture of steam and
water delivered into the drum will be steam, and that the water will make
110 circuits while being evaporated. Also that when worked at only about
one-quarter its rated capacity, one-fifth of the volume will be steam and the
water will make the rounds 870 times before it becomes steam. You will thus
see that in the proportions adopted in this boiler there is provision for perfect
circulation under all the possible conditions of practice.
In designing boilers of this style
it is necessary to guard against
having the uptake at the upper
end of the tubes too large, for if
sufficiently large to allow
downward currents therein, the
whole effect of the rising
column in increasing the
circulation in the tubes is
nullified (Fig. 7). This will
Fig. 8 [Developed to show Circulation] readily be seen if we consider
the uptake very large when the
only head producing circulation
in the tubes will be that due to the inclination of each tube taken by itself.
This objection is only overcome when the uptake is so small as to be entirely
filled with the ascending current of mingled steam and water. It is also
necessary that this uptake should be practically direct, and it should not be
composed of frequent enlargements and [Pg 34]
[Pg 35] contractions. Take, for instance, a boiler well known in Europe, copied
and sold here under another name. It is made up of inclined tubes secured by
pairs into boxes at the ends, which boxes are made to communicate with
each other by return bends opposite the ends of the tubes. These boxes and
return bends form an irregular uptake, whereby the steam is expected to rise
to a reservoir above. You will notice (Fig. 8) that the upward current of
steam and water in the return bend meets and directly antagonizes the
Page 48
upward current in the adjoining tube. Only one result can follow. If their
velocities are equal, the momentum of both will be neutralized and all
circulation stopped, or, if one be stronger, it will cause a back flow in the
other by the amount of difference in force, with practically the same result.
4880 Horse-power Installation of Babcock & Wilcox Boilers at the Open
Hearth Plant of the Cambria Steel Co., Johnstown, Pa. This Company
Operates a Total of 52,000 Horse Power of Babcock & Wilcox Boilers
In a well-known boiler, many of which were sold, but of which none are
now made and a very few are still in use, the inventor claimed that the return
bends and small openings against the tubes were for the purpose of
“restricting the circulation” and no doubt they performed well that office;
but excepting for the smallness of the openings they were not as efficient for
that purpose as the arrangement shown in Fig. 8.
Another form of boiler, first invented by Clarke or Crawford, and lately
revived, has the uptake made of boxes into which a number, generally from
two to four tubes, are expanded, the boxes being connected together by
nipples (Fig. 9). It is a well-known fact that where a fluid flows through a
velocities are equal, the momentum of both will be neutralized and all
circulation stopped, or, if one be stronger, it will cause a back flow in the
other by the amount of difference in force, with practically the same result.
4880 Horse-power Installation of Babcock & Wilcox Boilers at the Open
Hearth Plant of the Cambria Steel Co., Johnstown, Pa. This Company
Operates a Total of 52,000 Horse Power of Babcock & Wilcox Boilers
In a well-known boiler, many of which were sold, but of which none are
now made and a very few are still in use, the inventor claimed that the return
bends and small openings against the tubes were for the purpose of
“restricting the circulation” and no doubt they performed well that office;
but excepting for the smallness of the openings they were not as efficient for
that purpose as the arrangement shown in Fig. 8.
Another form of boiler, first invented by Clarke or Crawford, and lately
revived, has the uptake made of boxes into which a number, generally from
two to four tubes, are expanded, the boxes being connected together by
nipples (Fig. 9). It is a well-known fact that where a fluid flows through a
Page 49
conduit which enlarges and then contracts, the
velocity is lost to a greater or less extent at the
enlargements, and has to be gotten up again at the
contractions each time, with a corresponding loss of
head. The same thing occurs in the construction
shown in Fig. 9. The enlargements and contractions
quite destroy the head and practically overcome the
tendency of the water to circulate.
Fig. 9 A horizontal tube stopped at
one end, as shown in Fig.
10, can have no proper
circulation within it. If moderately driven, the
water may struggle in against the issuing steam
sufficiently to keep the surface covered, but a
slight degree of forcing will cause it to act like the
test tube in Fig. 3, and the more there are of them
in a given boiler the more spasmodic will be its
working. Fig. 10
The experiment with our kettle (Fig. 2) gives the
clue to the best means of promoting circulation in ordinary shell boilers.
Steenstrup or “Martin” and “Galloway” water tubes placed in such boilers
also assist in directing the circulation therein, but it is almost impossible to
produce in shell boilers, by any means the circulation of all the water in one
continuous round, such as marks the well-constructed water-tube boiler.
As I have before remarked, provision for a proper circulation of water has
been almost universally ignored in designing steam boilers, sometimes to the
great damage of the owner, but oftener to the jeopardy of the lives of those
who are employed to run them. The noted case of the Montana and her sister
ship, where some $300,000 [Pg 36] was thrown away in trying an experiment
which a proper consideration of this subject would have avoided, is a case in
point; but who shall count the cost of life and treasure not, perhaps, directly
traceable to, but, nevertheless, due entirely to such neglect in design and
construction of the thousands of boilers in which this necessary element has
been ignored?
velocity is lost to a greater or less extent at the
enlargements, and has to be gotten up again at the
contractions each time, with a corresponding loss of
head. The same thing occurs in the construction
shown in Fig. 9. The enlargements and contractions
quite destroy the head and practically overcome the
tendency of the water to circulate.
Fig. 9 A horizontal tube stopped at
one end, as shown in Fig.
10, can have no proper
circulation within it. If moderately driven, the
water may struggle in against the issuing steam
sufficiently to keep the surface covered, but a
slight degree of forcing will cause it to act like the
test tube in Fig. 3, and the more there are of them
in a given boiler the more spasmodic will be its
working. Fig. 10
The experiment with our kettle (Fig. 2) gives the
clue to the best means of promoting circulation in ordinary shell boilers.
Steenstrup or “Martin” and “Galloway” water tubes placed in such boilers
also assist in directing the circulation therein, but it is almost impossible to
produce in shell boilers, by any means the circulation of all the water in one
continuous round, such as marks the well-constructed water-tube boiler.
As I have before remarked, provision for a proper circulation of water has
been almost universally ignored in designing steam boilers, sometimes to the
great damage of the owner, but oftener to the jeopardy of the lives of those
who are employed to run them. The noted case of the Montana and her sister
ship, where some $300,000 [Pg 36] was thrown away in trying an experiment
which a proper consideration of this subject would have avoided, is a case in
point; but who shall count the cost of life and treasure not, perhaps, directly
traceable to, but, nevertheless, due entirely to such neglect in design and
construction of the thousands of boilers in which this necessary element has
been ignored?
Page 50
In the light of the performance of the exacting conditions of present day
power-plant practice, a review of this lecture and of the foregoing list of
requirements reveals the insight of the inventors of the Babcock & Wilcox
boiler into the fundamental principles of steam generator design and
construction.
Since the Babcock & Wilcox boiler became thoroughly established as a
durable and efficient steam generator, many types of water-tube boilers have
appeared on the market. Most of them, failing to meet enough of the
requirements of a perfect boiler, have fallen by the wayside, while a few
failing to meet all of the requirements, have only a limited field of
usefulness. None have been superior, and in the most cases the most ardent
admirers of other boilers have been satisfied in looking up to the Babcock &
Wilcox boiler as a standard and in claiming that the newer boilers were “just
as good.”
Records of recent performances under the most severe conditions of services
on land and sea, show that the Babcock & Wilcox boiler can be run
continually and regularly at higher overloads, with higher efficiency, and
lower upkeep cost than any other boiler on the market. It is especially
adapted for power-plant work where it is necessary to use a boiler in which
steam can be raised quickly and the boiler placed on the line either from a
cold state or from a banked fire in the shortest possible time, and with which
the capacity, with clean feed water, will be largely limited by the amount of
coal that can be burned in the furnace.
The distribution of the circulation through the separate headers and sections
and the action of the headers in forcing a maximum and continuous
circulation in the lower tubes, permit the operation of the Babcock & Wilcox
boiler without objectionable priming, with a higher degree of concentration
of salts in the water than is possible in any other type of boiler.
Repeated daily performances at overloads have demonstrated beyond a
doubt the correctness of Mr. Babcock’s computation regarding the
circulating tube and header area required for most efficient circulation. They
also have proved that enlargement of the area of headers and circulating
tubes beyond a certain point diminishes the head available for causing
power-plant practice, a review of this lecture and of the foregoing list of
requirements reveals the insight of the inventors of the Babcock & Wilcox
boiler into the fundamental principles of steam generator design and
construction.
Since the Babcock & Wilcox boiler became thoroughly established as a
durable and efficient steam generator, many types of water-tube boilers have
appeared on the market. Most of them, failing to meet enough of the
requirements of a perfect boiler, have fallen by the wayside, while a few
failing to meet all of the requirements, have only a limited field of
usefulness. None have been superior, and in the most cases the most ardent
admirers of other boilers have been satisfied in looking up to the Babcock &
Wilcox boiler as a standard and in claiming that the newer boilers were “just
as good.”
Records of recent performances under the most severe conditions of services
on land and sea, show that the Babcock & Wilcox boiler can be run
continually and regularly at higher overloads, with higher efficiency, and
lower upkeep cost than any other boiler on the market. It is especially
adapted for power-plant work where it is necessary to use a boiler in which
steam can be raised quickly and the boiler placed on the line either from a
cold state or from a banked fire in the shortest possible time, and with which
the capacity, with clean feed water, will be largely limited by the amount of
coal that can be burned in the furnace.
The distribution of the circulation through the separate headers and sections
and the action of the headers in forcing a maximum and continuous
circulation in the lower tubes, permit the operation of the Babcock & Wilcox
boiler without objectionable priming, with a higher degree of concentration
of salts in the water than is possible in any other type of boiler.
Repeated daily performances at overloads have demonstrated beyond a
doubt the correctness of Mr. Babcock’s computation regarding the
circulating tube and header area required for most efficient circulation. They
also have proved that enlargement of the area of headers and circulating
tubes beyond a certain point diminishes the head available for causing
Page 51
circulation and consequently limits the ability of the boiler to respond to
demands for overloads.
In this lecture Mr. Babcock made the prediction that with the circulating tube
area proportioned in accordance with the principles laid down, the Babcock
& Wilcox boiler could be continuously run at double its nominal rating,
which at that time was based on 12 square feet of heating surface per horse
power. This prediction is being fulfilled daily in all the large and prominent
power plants in this country and abroad, and it has been repeatedly
demonstrated that with clean water and clean tube surfaces it is possible to
safely operate at over 300 per cent of the nominal rating.
In the development of electrical power stations it becomes more and more
apparent that it is economical to run a boiler at high ratings during the times
of peak loads, as by so doing the lay-over losses are diminished and the
economy of the plant as a whole is increased.
[Pg 37]
The number and importance of the large electric lighting and power stations
constructed during the last ten years that are equipped with Babcock &
Wilcox boilers, is a most gratifying demonstration of the merit of the
apparatus, especially in view of their satisfactory operation under conditions
which are perhaps more exacting than those of any other service.
Time, the test of all, results with boilers as with other things, in the survival
of the fittest. When judged on this basis the Babcock & Wilcox boiler stands
pre-eminent in its ability to cover the whole field of steam generation with
the highest commercial efficiency obtainable. Year after year the Babcock &
Wilcox boiler has become more firmly established as the standard of
excellence in the boiler making art.
demands for overloads.
In this lecture Mr. Babcock made the prediction that with the circulating tube
area proportioned in accordance with the principles laid down, the Babcock
& Wilcox boiler could be continuously run at double its nominal rating,
which at that time was based on 12 square feet of heating surface per horse
power. This prediction is being fulfilled daily in all the large and prominent
power plants in this country and abroad, and it has been repeatedly
demonstrated that with clean water and clean tube surfaces it is possible to
safely operate at over 300 per cent of the nominal rating.
In the development of electrical power stations it becomes more and more
apparent that it is economical to run a boiler at high ratings during the times
of peak loads, as by so doing the lay-over losses are diminished and the
economy of the plant as a whole is increased.
[Pg 37]
The number and importance of the large electric lighting and power stations
constructed during the last ten years that are equipped with Babcock &
Wilcox boilers, is a most gratifying demonstration of the merit of the
apparatus, especially in view of their satisfactory operation under conditions
which are perhaps more exacting than those of any other service.
Time, the test of all, results with boilers as with other things, in the survival
of the fittest. When judged on this basis the Babcock & Wilcox boiler stands
pre-eminent in its ability to cover the whole field of steam generation with
the highest commercial efficiency obtainable. Year after year the Babcock &
Wilcox boiler has become more firmly established as the standard of
excellence in the boiler making art.
Page 52
South Boston Station of the Boston Elevated Ry. Co., Boston, Mass. 9600
Horse Power of Babcock & Wilcox Boilers and Superheaters Installed
in this Station
[Pg 38]
Horse Power of Babcock & Wilcox Boilers and Superheaters Installed
in this Station
[Pg 38]
Page 53
3600 Horse-power Installation of Babcock & Wilcox Boilers at the
Phipps Power House of the Duquesne Light Company, Pittsburgh, Pa.
Phipps Power House of the Duquesne Light Company, Pittsburgh, Pa.
Page 54
[Pg 39]
Page 55
EVOLUTION OF THE BABCOCK & WILCOX
WATER-TUBE BOILER
Quite as much may be learned from the records of failures as from those of
success. Where a device has been once fairly tried and found to be imperfect
or impracticable, the knowledge of that trial is of advantage in further
investigation. Regardless of the lesson taught by failure, however, it is an
almost every-day occurrence that some device or construction which has been
tried and found wanting, if not worthless, is again introduced as a great
improvement upon a device which has shown by its survival to be the fittest.
The success of the Babcock & Wilcox boiler is due to many years of constant
adherence to one line of research, in which an endeavor has been made to
introduce improvements with the view to producing a boiler which would
most effectively meet the demands of the times. During the periods that this
boiler has been built, other companies have placed on the market more than
thirty water-tube or sectional water-tube boilers, most of which, though they
may have attained some distinction and sale, have now entirely disappeared.
The following incomplete list will serve to recall the names of some of the
boilers that have had a vogue at various times, but which are now practically
unknown: Dimpfel, Howard, Griffith & Wundrum, Dinsmore, Miller “Fire
Box”, Miller “American”, Miller “Internal Tube”, Miller “Inclined Tube”,
Phleger, Weigant, the Lady Verner, the Allen, the Kelly, the Anderson, the
Rogers & Black, the Eclipse or Kilgore, the Moore, the Baker & Smith, the
Renshaw, the Shackleton, the “Duplex”, the Pond & Bradford, the
Whittingham, the Bee, the Hazleton or “Common Sense”, the Reynolds, the
Suplee or Luder, the Babbit, the Reed, the Smith, the Standard, etc., etc.
It is with the object of protecting our customers and friends from loss through
purchasing discarded ideas that there is given on the following pages a brief
history of the development of the Babcock & Wilcox boiler as it is built to-
day. The illustrations and brief descriptions indicate clearly the various
designs and constructions that have been used and that have been replaced, as
experience has shown in what way improvement might be made. They serve
as a history of the experimental steps in the development of the present
WATER-TUBE BOILER
Quite as much may be learned from the records of failures as from those of
success. Where a device has been once fairly tried and found to be imperfect
or impracticable, the knowledge of that trial is of advantage in further
investigation. Regardless of the lesson taught by failure, however, it is an
almost every-day occurrence that some device or construction which has been
tried and found wanting, if not worthless, is again introduced as a great
improvement upon a device which has shown by its survival to be the fittest.
The success of the Babcock & Wilcox boiler is due to many years of constant
adherence to one line of research, in which an endeavor has been made to
introduce improvements with the view to producing a boiler which would
most effectively meet the demands of the times. During the periods that this
boiler has been built, other companies have placed on the market more than
thirty water-tube or sectional water-tube boilers, most of which, though they
may have attained some distinction and sale, have now entirely disappeared.
The following incomplete list will serve to recall the names of some of the
boilers that have had a vogue at various times, but which are now practically
unknown: Dimpfel, Howard, Griffith & Wundrum, Dinsmore, Miller “Fire
Box”, Miller “American”, Miller “Internal Tube”, Miller “Inclined Tube”,
Phleger, Weigant, the Lady Verner, the Allen, the Kelly, the Anderson, the
Rogers & Black, the Eclipse or Kilgore, the Moore, the Baker & Smith, the
Renshaw, the Shackleton, the “Duplex”, the Pond & Bradford, the
Whittingham, the Bee, the Hazleton or “Common Sense”, the Reynolds, the
Suplee or Luder, the Babbit, the Reed, the Smith, the Standard, etc., etc.
It is with the object of protecting our customers and friends from loss through
purchasing discarded ideas that there is given on the following pages a brief
history of the development of the Babcock & Wilcox boiler as it is built to-
day. The illustrations and brief descriptions indicate clearly the various
designs and constructions that have been used and that have been replaced, as
experience has shown in what way improvement might be made. They serve
as a history of the experimental steps in the development of the present
Page 56
Babcock & Wilcox boiler, the value and success of which, as a steam
generator, is evidenced by the fact that the largest and most discriminating
users continue to purchase them after years of experience in their operation.
No. 1. The original Babcock &
Wilcox boiler was patented in 1867.
The main idea in its design was
safety, to which all other features
were sacrificed wherever they
conflicted. The boiler consisted of a
nest of horizontal tubes, serving as a
steam and water reservoir, placed
above and connected at each end by
bolted [Pg 40] joints to a second nest of
inclined heating tubes filled with No. 1
water. The tubes were placed one
above the other in vertical rows, each
row and its connecting end forming a single casting. Hand-holes were placed
at each end for cleaning. Internal tubes were placed within the inclined tubes
with a view to aiding circulation.
No. 2. This boiler was the same as No. 1, except that the internal circulating
tubes were omitted as they were found to hinder rather than help the
circulation.
Nos. 1 and 2 were found to be faulty in both material and design, cast metal
proving unfit for heating surfaces placed directly over the fire, as it cracked as
soon as any scale formed.
No. 3. Wrought-iron tubes were substituted for the cast-iron heating tubes, the
ends being brightened, laid in moulds, and the headers cast on.
The steam and water capacity in this design were insufficient to secure
regularity of action, there being no reserve upon which to draw during firing
or when the water was fed intermittently. The attempt to dry the steam by
superheating it in the nest of tubes forming the steam space was found to be
impracticable. The steam delivered was either wet, dry or superheated,
according to the rate at which it was being drawn from the boiler. Sediment
generator, is evidenced by the fact that the largest and most discriminating
users continue to purchase them after years of experience in their operation.
No. 1. The original Babcock &
Wilcox boiler was patented in 1867.
The main idea in its design was
safety, to which all other features
were sacrificed wherever they
conflicted. The boiler consisted of a
nest of horizontal tubes, serving as a
steam and water reservoir, placed
above and connected at each end by
bolted [Pg 40] joints to a second nest of
inclined heating tubes filled with No. 1
water. The tubes were placed one
above the other in vertical rows, each
row and its connecting end forming a single casting. Hand-holes were placed
at each end for cleaning. Internal tubes were placed within the inclined tubes
with a view to aiding circulation.
No. 2. This boiler was the same as No. 1, except that the internal circulating
tubes were omitted as they were found to hinder rather than help the
circulation.
Nos. 1 and 2 were found to be faulty in both material and design, cast metal
proving unfit for heating surfaces placed directly over the fire, as it cracked as
soon as any scale formed.
No. 3. Wrought-iron tubes were substituted for the cast-iron heating tubes, the
ends being brightened, laid in moulds, and the headers cast on.
The steam and water capacity in this design were insufficient to secure
regularity of action, there being no reserve upon which to draw during firing
or when the water was fed intermittently. The attempt to dry the steam by
superheating it in the nest of tubes forming the steam space was found to be
impracticable. The steam delivered was either wet, dry or superheated,
according to the rate at which it was being drawn from the boiler. Sediment
Page 57
was found to lodge in the lowermost point of the boiler at the rear end and the
exposed portions cracked off at this point when subjected to the furnace heat.
No. 4. A plain cylinder, carrying the
water line at its center and leaving
the upper half for steam space, was
substituted for the nest of tubes
forming the steam and water space in
Nos. 1, 2 and 3. The sections were
made as in No. 3 and a mud drum
added to the rear end of the sections
No. 4 at the point that was lowest and
farthest removed from the fire. The
gases were made to pass off at one
side and did not come into contact with the mud drum. Dry steam was
obtained through the increase of separating surface and steam space and the
added water capacity furnished a storage for heat to tide over irregularities of
firing and feeding. By the addition of the drum, the boiler became a
serviceable and practical design, retaining all of the features of safety. As the
drum was removed from the direct action of the fire, it was not subjected to
excessive strain due to unequal expansion, and its diameter, if large in
comparison with that of the tubes formerly used, was small when compared
with that of cylindrical boilers. Difficulties were encountered in this boiler in
securing reliable joints between the wrought-iron tubes and the cast-iron
headers.
No. 5. In this design, wrought-iron
water legs were substituted for the
cast-iron headers, the tubes being
expanded into the inside sheets and a
large [Pg 41] cover placed opposite the
front end of the tubes for cleaning.
The tubes were staggered one above
the other, an arrangement found to be
more efficient in the absorption of No. 5
heat than where they were placed in
vertical rows. In other respects, the
boiler was similar to No. 4, except that it had lost the important element of
exposed portions cracked off at this point when subjected to the furnace heat.
No. 4. A plain cylinder, carrying the
water line at its center and leaving
the upper half for steam space, was
substituted for the nest of tubes
forming the steam and water space in
Nos. 1, 2 and 3. The sections were
made as in No. 3 and a mud drum
added to the rear end of the sections
No. 4 at the point that was lowest and
farthest removed from the fire. The
gases were made to pass off at one
side and did not come into contact with the mud drum. Dry steam was
obtained through the increase of separating surface and steam space and the
added water capacity furnished a storage for heat to tide over irregularities of
firing and feeding. By the addition of the drum, the boiler became a
serviceable and practical design, retaining all of the features of safety. As the
drum was removed from the direct action of the fire, it was not subjected to
excessive strain due to unequal expansion, and its diameter, if large in
comparison with that of the tubes formerly used, was small when compared
with that of cylindrical boilers. Difficulties were encountered in this boiler in
securing reliable joints between the wrought-iron tubes and the cast-iron
headers.
No. 5. In this design, wrought-iron
water legs were substituted for the
cast-iron headers, the tubes being
expanded into the inside sheets and a
large [Pg 41] cover placed opposite the
front end of the tubes for cleaning.
The tubes were staggered one above
the other, an arrangement found to be
more efficient in the absorption of No. 5
heat than where they were placed in
vertical rows. In other respects, the
boiler was similar to No. 4, except that it had lost the important element of
Page 58
safety through the introduction of the very objectionable feature of flat stayed
surfaces. The large doors for access to the tubes were also a cause of
weakness.
An installation of these boilers was made at the plant of the Calvert Sugar
Refinery in Baltimore, and while they were satisfactory in their operation,
were never duplicated.
No. 6. This was a modification of
No. 5 in which longer tubes were
used and over which the gases were
caused to make three passes with a
view of better economy. In addition,
some of the stayed surfaces were
omitted and handholes substituted
for the large access doors. A number
of boilers of this design were built
No. 6
but their excessive first cost, the lack
of adjustability of the structure
under varying temperatures, and the
inconvenience of transportation, led to No. 7.
No. 7. In this boiler, the headers and water
legs were replaced by T-heads screwed to
the ends of the inclined tubes. The faces of
these Ts were milled and the tubes placed
one above the other with the milled faces
metal to metal. Long bolts passed through
each vertical section of the T-heads and
through connecting boxes on the heads of
the drums holding the whole together. A
large number of boilers of this design were No. 7
built and many were in successful
operation for over twenty years. In most
instances, however, they were altered to later types.
surfaces. The large doors for access to the tubes were also a cause of
weakness.
An installation of these boilers was made at the plant of the Calvert Sugar
Refinery in Baltimore, and while they were satisfactory in their operation,
were never duplicated.
No. 6. This was a modification of
No. 5 in which longer tubes were
used and over which the gases were
caused to make three passes with a
view of better economy. In addition,
some of the stayed surfaces were
omitted and handholes substituted
for the large access doors. A number
of boilers of this design were built
No. 6
but their excessive first cost, the lack
of adjustability of the structure
under varying temperatures, and the
inconvenience of transportation, led to No. 7.
No. 7. In this boiler, the headers and water
legs were replaced by T-heads screwed to
the ends of the inclined tubes. The faces of
these Ts were milled and the tubes placed
one above the other with the milled faces
metal to metal. Long bolts passed through
each vertical section of the T-heads and
through connecting boxes on the heads of
the drums holding the whole together. A
large number of boilers of this design were No. 7
built and many were in successful
operation for over twenty years. In most
instances, however, they were altered to later types.
Page 59
No . 8 No. 9
[Pg 42]
Nos. 8 and 9. These boilers were known as the Griffith & Wundrum type, the
concern which built them being later merged in The Babcock & Wilcox Co.
Experiments were made with this design with four passages of the gases
across the tubes and the downward circulation of the water at the rear of the
boiler was carried to the bottom row of tubes. In No. 9 an attempt was made
to increase the safety and reduce the cost by reducing the amount of steam
and water capacity. A drum at right angles to the line of tubes was used but as
there was no provision made to secure dry steam, the results were not
satisfactory. The next move in the direction of safety was the employment of
several drums of small diameter instead of a single drum.
This is shown in No. 10. A nest of
small horizontal drums, 15 inches in
diameter, was used in place of the
single drum of larger diameter. A set
of circulation tubes was placed at an
intermediate angle between the main
bank of heating tubes and the
horizontal drums forming the steam
No. 10 reservoir. These circulators were to
return to the rear end of the circulating
tubes the water carried up by the
circulation, and in this way were to allow only steam to be delivered to the
[Pg 42]
Nos. 8 and 9. These boilers were known as the Griffith & Wundrum type, the
concern which built them being later merged in The Babcock & Wilcox Co.
Experiments were made with this design with four passages of the gases
across the tubes and the downward circulation of the water at the rear of the
boiler was carried to the bottom row of tubes. In No. 9 an attempt was made
to increase the safety and reduce the cost by reducing the amount of steam
and water capacity. A drum at right angles to the line of tubes was used but as
there was no provision made to secure dry steam, the results were not
satisfactory. The next move in the direction of safety was the employment of
several drums of small diameter instead of a single drum.
This is shown in No. 10. A nest of
small horizontal drums, 15 inches in
diameter, was used in place of the
single drum of larger diameter. A set
of circulation tubes was placed at an
intermediate angle between the main
bank of heating tubes and the
horizontal drums forming the steam
No. 10 reservoir. These circulators were to
return to the rear end of the circulating
tubes the water carried up by the
circulation, and in this way were to allow only steam to be delivered to the
Page 60
small drums above. There was no improvement in the action of this boiler
over that of No. 9.
The four passages of the gas over the tubes tried in Nos. 8, 9 and 10 were not
found to add to the economy of the boiler.
No. 11. A trial was next made of a box coil
system, in which the water was made to
transverse the furnace several times before being
delivered to the drum above. The tendency here,
as in all similar boilers, was to form steam in the
middle of the coil and blow the water from each
end, leaving the tubes practically dry until the
steam found an outlet and the water returned.
This boiler had, in addition to a defective No. 11
circulation, a decidedly geyser-like action and
produced wet steam.
All of the types mentioned, with
the exception of Nos. 5 and 6, had
between their several parts a large
number of bolted joints which
were subjected to the action [Pg 43]
of the fire. When these boilers
were placed in operation it was
demonstrated that as soon as any
scale formed on the heating
surfaces, leaks were caused due to
unequal expansion.
No. 12. With this boiler, an
No. 12 attempt was made to remove the
joints from the fire and to increase
the heating surface in a given
space. Water tubes were expanded into both sides of wrought-iron boxes,
openings being made for the admission of water and the exit of steam. Fire
tubes were placed inside the water tubes to increase the heating surface. This
design was abandoned because of the rapid stopping up of the tubes by scale
and the impossibility of cleaning them.
over that of No. 9.
The four passages of the gas over the tubes tried in Nos. 8, 9 and 10 were not
found to add to the economy of the boiler.
No. 11. A trial was next made of a box coil
system, in which the water was made to
transverse the furnace several times before being
delivered to the drum above. The tendency here,
as in all similar boilers, was to form steam in the
middle of the coil and blow the water from each
end, leaving the tubes practically dry until the
steam found an outlet and the water returned.
This boiler had, in addition to a defective No. 11
circulation, a decidedly geyser-like action and
produced wet steam.
All of the types mentioned, with
the exception of Nos. 5 and 6, had
between their several parts a large
number of bolted joints which
were subjected to the action [Pg 43]
of the fire. When these boilers
were placed in operation it was
demonstrated that as soon as any
scale formed on the heating
surfaces, leaks were caused due to
unequal expansion.
No. 12. With this boiler, an
No. 12 attempt was made to remove the
joints from the fire and to increase
the heating surface in a given
space. Water tubes were expanded into both sides of wrought-iron boxes,
openings being made for the admission of water and the exit of steam. Fire
tubes were placed inside the water tubes to increase the heating surface. This
design was abandoned because of the rapid stopping up of the tubes by scale
and the impossibility of cleaning them.
Page 61
No. 13. Vertical straight line headers of
cast iron, each containing two rows of
tubes, were bolted to a connection leading
to the steam and water drum above.
N
o.
14
.A
wr
ou
gh
t- No. 13
iro
n
box was substituted for the double
cast-iron headers. In this design, stays
No. 14 were necessary and were found, as
always, to be an element to be avoided
wherever possible. The boiler was an
improvement on No. 6, however. A slanting bridge wall was introduced
underneath the drum to throw a larger portion of its heating surface into the
combustion chamber under the bank of tubes.
This bridge wall was found to be difficult to keep in repair and was of no
particular benefit.
No. 15. Each row of tubes was expanded at each end into a continuous
header, cast of car wheel metal. The headers had a sinuous form so that they
would lie close together and admit of a staggered position of the tubes when
assembled. While other designs of header form were tried later, experience
with Nos. 14 and 15 showed that the style here adopted was the best for all
[Pg 44] purposes and it has not been changed materially since. The drum in this
design was supported by girders resting on the brickwork. Bolted joints were
discarded, with the exception of those connecting the headers to the front and
rear ends of the drums and the bottom of the rear headers to the mud drum.
Even such joints, however, were found objectionable and were superseded in
subsequent construction by short lengths of tubes expanded into bored holes.
cast iron, each containing two rows of
tubes, were bolted to a connection leading
to the steam and water drum above.
N
o.
14
.A
wr
ou
gh
t- No. 13
iro
n
box was substituted for the double
cast-iron headers. In this design, stays
No. 14 were necessary and were found, as
always, to be an element to be avoided
wherever possible. The boiler was an
improvement on No. 6, however. A slanting bridge wall was introduced
underneath the drum to throw a larger portion of its heating surface into the
combustion chamber under the bank of tubes.
This bridge wall was found to be difficult to keep in repair and was of no
particular benefit.
No. 15. Each row of tubes was expanded at each end into a continuous
header, cast of car wheel metal. The headers had a sinuous form so that they
would lie close together and admit of a staggered position of the tubes when
assembled. While other designs of header form were tried later, experience
with Nos. 14 and 15 showed that the style here adopted was the best for all
[Pg 44] purposes and it has not been changed materially since. The drum in this
design was supported by girders resting on the brickwork. Bolted joints were
discarded, with the exception of those connecting the headers to the front and
rear ends of the drums and the bottom of the rear headers to the mud drum.
Even such joints, however, were found objectionable and were superseded in
subsequent construction by short lengths of tubes expanded into bored holes.
Page 62
No. 15
No. 16
No. 16. In this design, headers were tried which were made in the form of
triangular boxes, in each of which there were three tubes expanded. These
boxes were alternately reversed and connected by short lengths of expanded
tubes, being connected to the drum by tubes bent in a manner to allow them
to enter the shell normally. The joints between headers introduced an element
of weakness and the connections to the drum were insufficient to give
adequate circulation.
No. 16
No. 16. In this design, headers were tried which were made in the form of
triangular boxes, in each of which there were three tubes expanded. These
boxes were alternately reversed and connected by short lengths of expanded
tubes, being connected to the drum by tubes bent in a manner to allow them
to enter the shell normally. The joints between headers introduced an element
of weakness and the connections to the drum were insufficient to give
adequate circulation.
Page 63
No. 17
No. 17. Straight horizontal headers were next tried, alternately shifted right
and left to allow a staggering of tubes. These headers were connected to each
other [Pg 45] and to the drums by expanded nipples. The objections to this
boiler were almost the same as those to No. 16.
No. 18 No. 19
Nos. 18 and 19. These boilers were designed primarily for fire protection
purposes, the requirements demanding a small, compact boiler with ability to
raise steam quickly. These both served the purpose admirably but, as in No. 9,
the only provision made for the securing of dry steam was the use of the
steam dome, shown in the illustration. This dome was found inadequate and
has since been abandoned in nearly all forms of boiler construction. No other
remedy being suggested at the time, these boilers were not considered as
desirable for general use as Nos. 21 and 22. In Europe, however, where small
No. 17. Straight horizontal headers were next tried, alternately shifted right
and left to allow a staggering of tubes. These headers were connected to each
other [Pg 45] and to the drums by expanded nipples. The objections to this
boiler were almost the same as those to No. 16.
No. 18 No. 19
Nos. 18 and 19. These boilers were designed primarily for fire protection
purposes, the requirements demanding a small, compact boiler with ability to
raise steam quickly. These both served the purpose admirably but, as in No. 9,
the only provision made for the securing of dry steam was the use of the
steam dome, shown in the illustration. This dome was found inadequate and
has since been abandoned in nearly all forms of boiler construction. No other
remedy being suggested at the time, these boilers were not considered as
desirable for general use as Nos. 21 and 22. In Europe, however, where small
Page 64
size units were more in demand, No. 18 was modified somewhat and used
largely with excellent results. These experiments, as they may now be called,
although many boilers of some of the designs were built, clearly
demonstrated that the best construction and efficiency required adherence to
the following elements of design:
1st. Sinuous headers for each vertical row of tubes.
2nd. A separate and independent connection with the drum, both front and
rear, for each vertical row of tubes.
[Pg 46]
3rd. All joints between parts of the boiler proper to be made without bolts or
screw plates.
4th. No surfaces to be used which necessitate the use of stays.
5th. The boiler supported independently of the brickwork so as to allow
freedom for expansion and contraction as it is heated or cooled.
6th. Ample diameter of steam and water drums, these not to be less than 30
inches except for small size units.
7th. Every part accessible for cleaning and repairs.
No. 20A No. 20B
largely with excellent results. These experiments, as they may now be called,
although many boilers of some of the designs were built, clearly
demonstrated that the best construction and efficiency required adherence to
the following elements of design:
1st. Sinuous headers for each vertical row of tubes.
2nd. A separate and independent connection with the drum, both front and
rear, for each vertical row of tubes.
[Pg 46]
3rd. All joints between parts of the boiler proper to be made without bolts or
screw plates.
4th. No surfaces to be used which necessitate the use of stays.
5th. The boiler supported independently of the brickwork so as to allow
freedom for expansion and contraction as it is heated or cooled.
6th. Ample diameter of steam and water drums, these not to be less than 30
inches except for small size units.
7th. Every part accessible for cleaning and repairs.
No. 20A No. 20B
Page 65
With these points having been determined, No. 20 was designed. This boiler
had all the desirable features just enumerated, together with a number of
improvements as to detail of construction. The general form of No. 15 was
adhered to but the bolted connections between sections and drum and sections
and mud drum were discarded in favor of connections made by short lengths
of boiler tubes expanded into the adjacent parts. This boiler was suspended
from girders, like No. 15, but these in turn were carried on vertical supports,
leaving the pressure parts entirely free from the brickwork, the mutually
deteriorating strains present where one was supported by the other being in
this way overcome. Hundreds of thousands of horse power of this design
were built, giving great satisfaction. The boiler was known as the “C. I. F.”
(cast-iron front) style, an ornamental cast-iron front having been usually
furnished.
The next step, and the one which
connects the boilers as described
above to the boiler as it is built to-
day, was the design illustrated in
No. 21. These boilers were known
as the “W. I. F.” style, the fronts
furnished as part of the equipment
being constructed largely of
wrought iron. The cast-iron
drumheads used in No. 20 were
replaced by wrought-steel flanged
No. 21 and “bumped” heads. The drums
were made longer and the sections
connected to wrought-steel cross
boxes riveted to the bottom of the drums. The boilers were supported by
girders and columns as in No. 20.
[Pg 47]
No. 22. This boiler, which is designated as the “Vertical Header” type, has the
same general features of construction as No. 21, except that the tube sheet
side of the headers is “stepped” to allow the headers to be placed vertically
and at right angles to the drum and still maintain the tubes at the angle used in
Nos. 20 and 21.
had all the desirable features just enumerated, together with a number of
improvements as to detail of construction. The general form of No. 15 was
adhered to but the bolted connections between sections and drum and sections
and mud drum were discarded in favor of connections made by short lengths
of boiler tubes expanded into the adjacent parts. This boiler was suspended
from girders, like No. 15, but these in turn were carried on vertical supports,
leaving the pressure parts entirely free from the brickwork, the mutually
deteriorating strains present where one was supported by the other being in
this way overcome. Hundreds of thousands of horse power of this design
were built, giving great satisfaction. The boiler was known as the “C. I. F.”
(cast-iron front) style, an ornamental cast-iron front having been usually
furnished.
The next step, and the one which
connects the boilers as described
above to the boiler as it is built to-
day, was the design illustrated in
No. 21. These boilers were known
as the “W. I. F.” style, the fronts
furnished as part of the equipment
being constructed largely of
wrought iron. The cast-iron
drumheads used in No. 20 were
replaced by wrought-steel flanged
No. 21 and “bumped” heads. The drums
were made longer and the sections
connected to wrought-steel cross
boxes riveted to the bottom of the drums. The boilers were supported by
girders and columns as in No. 20.
[Pg 47]
No. 22. This boiler, which is designated as the “Vertical Header” type, has the
same general features of construction as No. 21, except that the tube sheet
side of the headers is “stepped” to allow the headers to be placed vertically
and at right angles to the drum and still maintain the tubes at the angle used in
Nos. 20 and 21.
Page 66
No. 22
No. 23, or the cross drum design
of boiler, is a development of the
Babcock & Wilcox marine
boiler, in which the cross drum is
used exclusively. The experience
of the Glasgow Works of The
Babcock & Wilcox, Ltd., with
No. 18 proved that proper
attention to details of
No. 23 construction would make it a
most desirable form of boiler
where headroom was limited. A
large number of this design have been successfully installed and are giving
satisfactory results under widely varying conditions. The cross drum boiler is
also built in a vertical header design.
Boilers Nos. 21, 22 and 23, with a few modifications, are now the standard
forms. These designs are illustrated, as they are constructed to-day, on pages
48, 52, 54, 58 and 60.
The last step in the development of the water-tube boiler, beyond which it
seems almost impossible for science and skill to advance, consists in the
making of all pressure parts of the boiler of wrought steel, including sinuous
headers, cross boxes, nozzles, and the like. This construction was the result of
the demands of certain Continental laws that are coming into general vogue in
No. 23, or the cross drum design
of boiler, is a development of the
Babcock & Wilcox marine
boiler, in which the cross drum is
used exclusively. The experience
of the Glasgow Works of The
Babcock & Wilcox, Ltd., with
No. 18 proved that proper
attention to details of
No. 23 construction would make it a
most desirable form of boiler
where headroom was limited. A
large number of this design have been successfully installed and are giving
satisfactory results under widely varying conditions. The cross drum boiler is
also built in a vertical header design.
Boilers Nos. 21, 22 and 23, with a few modifications, are now the standard
forms. These designs are illustrated, as they are constructed to-day, on pages
48, 52, 54, 58 and 60.
The last step in the development of the water-tube boiler, beyond which it
seems almost impossible for science and skill to advance, consists in the
making of all pressure parts of the boiler of wrought steel, including sinuous
headers, cross boxes, nozzles, and the like. This construction was the result of
the demands of certain Continental laws that are coming into general vogue in
Page 67
this country. The Babcock & Wilcox Co. have at the present time a plant
producing steel forgings that have been pronounced by the London Engineer
to be “a perfect triumph of the forgers’ art”.
The various designs of this all wrought-steel boiler are fully illustrated in the
following pages.
[Pg 48]
Wrought-steel Vertical Header Longitudinal Drum Babcock & Wilcox
Boiler, Equipped with Babcock & Wilcox Superheater and Babcock &
Wilcox Chain Grate Stoker
producing steel forgings that have been pronounced by the London Engineer
to be “a perfect triumph of the forgers’ art”.
The various designs of this all wrought-steel boiler are fully illustrated in the
following pages.
[Pg 48]
Wrought-steel Vertical Header Longitudinal Drum Babcock & Wilcox
Boiler, Equipped with Babcock & Wilcox Superheater and Babcock &
Wilcox Chain Grate Stoker
Page 68
[Pg 49]
Page 69
THE BABCOCK & WILCOX BOILER
The following brief description of the Babcock & Wilcox boiler will clearly
indicate the manner in which it fulfills the requirements of the perfect steam
boiler already enumerated.
The Babcock & Wilcox boiler is built in two general classes, the longitudinal
drum type and the cross drum type. Either of these designs may be
constructed with vertical or inclined headers, and the headers in turn may be
of wrought steel or cast iron dependent upon the working pressure for which
the boiler is constructed. The headers may be of different lengths, that is,
may connect different numbers of tubes, and it is by a change in the number
of tubes in height per section and the number of sections in width that the
size of the boiler is varied.
The longitudinal drum boiler is the generally accepted standard of Babcock
& Wilcox construction. The cross drum boiler, though originally designed to
meet certain conditions of headroom, has become popular for numerous
classes of work where low headroom is not a requirement which must be
met.
LONGITUDINAL DRUM CONSTRUCTION
—The heating surface of this type of boiler is
made up of a drum or drums, depending upon
the width of the boiler extending longitudinally
over the other pressure parts. To the drum or
drums there are connected through cross boxes
at either end the sections, which are made up
of headers and tubes. At the lower end of the
sections there is a mud drum extending
entirely across the setting and connected to all
Forged-steel Drumhead sections. The connections between all parts are
with Manhole Plate by short lengths of tubes expanded into bored
in Position seats.
The following brief description of the Babcock & Wilcox boiler will clearly
indicate the manner in which it fulfills the requirements of the perfect steam
boiler already enumerated.
The Babcock & Wilcox boiler is built in two general classes, the longitudinal
drum type and the cross drum type. Either of these designs may be
constructed with vertical or inclined headers, and the headers in turn may be
of wrought steel or cast iron dependent upon the working pressure for which
the boiler is constructed. The headers may be of different lengths, that is,
may connect different numbers of tubes, and it is by a change in the number
of tubes in height per section and the number of sections in width that the
size of the boiler is varied.
The longitudinal drum boiler is the generally accepted standard of Babcock
& Wilcox construction. The cross drum boiler, though originally designed to
meet certain conditions of headroom, has become popular for numerous
classes of work where low headroom is not a requirement which must be
met.
LONGITUDINAL DRUM CONSTRUCTION
—The heating surface of this type of boiler is
made up of a drum or drums, depending upon
the width of the boiler extending longitudinally
over the other pressure parts. To the drum or
drums there are connected through cross boxes
at either end the sections, which are made up
of headers and tubes. At the lower end of the
sections there is a mud drum extending
entirely across the setting and connected to all
Forged-steel Drumhead sections. The connections between all parts are
with Manhole Plate by short lengths of tubes expanded into bored
in Position seats.
Page 70
The drums are of three sheets, of such
thickness as to give the required factor of
safety under the maximum pressure for which
the boiler is constructed. The circular seams
are ordinarily single lap riveted though these
may be double lap riveted to meet certain
requirements of pressure or of specifications.
The longitudinal seams are properly
proportioned butt and strap or lap riveted joints
dependent upon the pressure for which the
boilers are built. Where butt strap joints are Forged-steel Drumhead
used the straps are bent to the proper radius in Interior
an hydraulic press. The courses are built
independently to template and are assembled
by an hydraulic forcing press. All riveted holes are punched one-quarter inch
smaller than the size of rivets as driven and are reamed to full size after the
plates are assembled. All rivets are driven by hydraulic pressure and held
until black.
The drumheads are hydraulic forged at a single heat, the manhole opening
and stiffening ring being forged in position. Flat raised seats for water
column and feed connections are formed in the forging.
[Pg 50]
All heads are provided with manholes, the edges of which are turned true.
The manhole plates are of forged steel and turned to fit manhole opening.
These plates are held in position by forged-steel guards and bolts.
The drum nozzles are of forged steel, faced,
and fitted with taper thread stud bolts.
Cross boxes by means of which the
sections are attached to the drums, are of
Forged-steel Drum Nozzle forged steel, made from a single sheet.
Where two or more drums are used in one boiler they are connected by a
cross pipe having a flanged outlet for the steam connection.
thickness as to give the required factor of
safety under the maximum pressure for which
the boiler is constructed. The circular seams
are ordinarily single lap riveted though these
may be double lap riveted to meet certain
requirements of pressure or of specifications.
The longitudinal seams are properly
proportioned butt and strap or lap riveted joints
dependent upon the pressure for which the
boilers are built. Where butt strap joints are Forged-steel Drumhead
used the straps are bent to the proper radius in Interior
an hydraulic press. The courses are built
independently to template and are assembled
by an hydraulic forcing press. All riveted holes are punched one-quarter inch
smaller than the size of rivets as driven and are reamed to full size after the
plates are assembled. All rivets are driven by hydraulic pressure and held
until black.
The drumheads are hydraulic forged at a single heat, the manhole opening
and stiffening ring being forged in position. Flat raised seats for water
column and feed connections are formed in the forging.
[Pg 50]
All heads are provided with manholes, the edges of which are turned true.
The manhole plates are of forged steel and turned to fit manhole opening.
These plates are held in position by forged-steel guards and bolts.
The drum nozzles are of forged steel, faced,
and fitted with taper thread stud bolts.
Cross boxes by means of which the
sections are attached to the drums, are of
Forged-steel Drum Nozzle forged steel, made from a single sheet.
Where two or more drums are used in one boiler they are connected by a
cross pipe having a flanged outlet for the steam connection.
Page 71
The
sectio
ns are
built
of 4-
inch
hot
finishe Forged-steel Cross Box
d
seaml
ess open-hearth steel tubes of No. 10 B. W. G. where the boilers are built for
working pressures up to 210 pounds. Where the working pressure is to be
above this and below 260 pounds, No. 9 B. W. G. tubes are supplied.
The tubes are
expanded into headers
of serpentine or
sinuous form, which
dispose the tubes in a
staggered position
Inside Handhole Fittings when assembled as a
Wrought-steel complete boiler. These
Vertical Header headers are of wrought
steel or of cast iron,
the latter being
ordinarily supplied where the working pressure is not
to exceed 160 pounds. The headers may be either
vertical or inclined as shown in the various
illustrations of assembled boilers.
Opposite each tube end in the headers there is placed
a handhole of sufficient size to permit the cleaning, Wrought-steel
removal or renewal of a tube. These openings in the Vertical Header
wrought steel vertical headers are elliptical in shape,
machine faced, and milled to a true plane back from
the edge a sufficient distance to make a seat. The openings are closed by
inside fitting forged plates, shouldered to center in the opening, their flanged
seats milled to a true plane. These plates are held in position by studs and
sectio
ns are
built
of 4-
inch
hot
finishe Forged-steel Cross Box
d
seaml
ess open-hearth steel tubes of No. 10 B. W. G. where the boilers are built for
working pressures up to 210 pounds. Where the working pressure is to be
above this and below 260 pounds, No. 9 B. W. G. tubes are supplied.
The tubes are
expanded into headers
of serpentine or
sinuous form, which
dispose the tubes in a
staggered position
Inside Handhole Fittings when assembled as a
Wrought-steel complete boiler. These
Vertical Header headers are of wrought
steel or of cast iron,
the latter being
ordinarily supplied where the working pressure is not
to exceed 160 pounds. The headers may be either
vertical or inclined as shown in the various
illustrations of assembled boilers.
Opposite each tube end in the headers there is placed
a handhole of sufficient size to permit the cleaning, Wrought-steel
removal or renewal of a tube. These openings in the Vertical Header
wrought steel vertical headers are elliptical in shape,
machine faced, and milled to a true plane back from
the edge a sufficient distance to make a seat. The openings are closed by
inside fitting forged plates, shouldered to center in the opening, their flanged
seats milled to a true plane. These plates are held in position by studs and
Page 72
forged-steel [Pg 51] binders and nuts. The joints between plates and headers
are made with a thin gasket.
In the wrought-steel
inclined headers the
handhole openings are
either circular or
elliptical, the former
being ordinarily
supplied. The circular
openings have a raised Inside Handhole Fitting
seat milled to a true Wrought-steel
plane. The openings are Inclined Header
closed on the outside by
forged-steel caps, milled
and ground true, held in position by forged-steel safety
clamps and secured by ball-headed bolts to assure
correct alignment. With this style of fitting, joints are
made tight, metal to metal, without packing of any
kind.
Wrought-steel
Inclined Header Where elliptical handholes are furnished they are
faced inside, closed by inside fitting forged-steel
plates, held to their seats by studs and secured by
forged-steel binders and nuts.
The joints between plates and header are made with a thin gasket.
The vertical cast-iron headers have elliptical handholes with raised seats
milled to a true plane. These are closed on the outside by cast-iron caps
milled true, held in position by forged-steel safety clamps, which close the
openings from the inside and which are secured by ball-headed bolts to
assure proper alignment. All joints are made tight, metal to metal, without
packing of any kind.
The mud drum to which the sections are attached at the lower end of the rear
headers, is a forged-steel box 7¼ inches square, and of such length as to be
connected to all headers by means of wrought nipples expanded into
are made with a thin gasket.
In the wrought-steel
inclined headers the
handhole openings are
either circular or
elliptical, the former
being ordinarily
supplied. The circular
openings have a raised Inside Handhole Fitting
seat milled to a true Wrought-steel
plane. The openings are Inclined Header
closed on the outside by
forged-steel caps, milled
and ground true, held in position by forged-steel safety
clamps and secured by ball-headed bolts to assure
correct alignment. With this style of fitting, joints are
made tight, metal to metal, without packing of any
kind.
Wrought-steel
Inclined Header Where elliptical handholes are furnished they are
faced inside, closed by inside fitting forged-steel
plates, held to their seats by studs and secured by
forged-steel binders and nuts.
The joints between plates and header are made with a thin gasket.
The vertical cast-iron headers have elliptical handholes with raised seats
milled to a true plane. These are closed on the outside by cast-iron caps
milled true, held in position by forged-steel safety clamps, which close the
openings from the inside and which are secured by ball-headed bolts to
assure proper alignment. All joints are made tight, metal to metal, without
packing of any kind.
The mud drum to which the sections are attached at the lower end of the rear
headers, is a forged-steel box 7¼ inches square, and of such length as to be
connected to all headers by means of wrought nipples expanded into
Page 73
counterbored seats. The mud drum is
furnished with handholes for cleaning,
these being closed from the inside by
forged-steel plates with studs, and secured
on a faced seat in the mud drum by forged-
steel binders and nuts. The joints between
the plates and the drum are made with thin
gaskets. The mud drum is tapped for blow-
off connection.
All connections between drums and
sections and between sections and mud
drum are of hot finished seamless open-
hearth steel tubes of No. 9 B. W. G.
Boilers of the longitudinal drum type are
suspended front and rear from wrought-
steel supporting frames entirely Cast-iron Vertical Header
independent of the brickwork. This allows
for [Pg 52]
[Pg 53] expansion and contraction of the pressure parts without straining
either the boiler or the brickwork, and also allows of brickwork repair or
renewal without in any way disturbing the boiler or its connections.
furnished with handholes for cleaning,
these being closed from the inside by
forged-steel plates with studs, and secured
on a faced seat in the mud drum by forged-
steel binders and nuts. The joints between
the plates and the drum are made with thin
gaskets. The mud drum is tapped for blow-
off connection.
All connections between drums and
sections and between sections and mud
drum are of hot finished seamless open-
hearth steel tubes of No. 9 B. W. G.
Boilers of the longitudinal drum type are
suspended front and rear from wrought-
steel supporting frames entirely Cast-iron Vertical Header
independent of the brickwork. This allows
for [Pg 52]
[Pg 53] expansion and contraction of the pressure parts without straining
either the boiler or the brickwork, and also allows of brickwork repair or
renewal without in any way disturbing the boiler or its connections.
Page 74
Babcock & Wilcox Wrought-steel Vertical Header Cross Drum Boiler
CROSS DRUM CONSTRUCTION—The cross drum type of boilers differs
from the longitudinal only in drum construction and method of support. The
drum in this type is placed transversely across the rear of the boiler and is
connected to the sections by means of circulating tubes expanded into bored
seats.
The drums for all pressures are of two sheets of sufficient thickness to give
the required factor of safety. The longitudinal seams are double riveted butt
strapped, the straps being bent to the proper radius in an hydraulic press. The
circulating tubes are expanded into the drums at the seams, the butt straps
serving as tube seats.
The drumheads, drum fittings and features of riveting are the same in the
cross drum as in the longitudinal types. The sections and mud drum are also
CROSS DRUM CONSTRUCTION—The cross drum type of boilers differs
from the longitudinal only in drum construction and method of support. The
drum in this type is placed transversely across the rear of the boiler and is
connected to the sections by means of circulating tubes expanded into bored
seats.
The drums for all pressures are of two sheets of sufficient thickness to give
the required factor of safety. The longitudinal seams are double riveted butt
strapped, the straps being bent to the proper radius in an hydraulic press. The
circulating tubes are expanded into the drums at the seams, the butt straps
serving as tube seats.
The drumheads, drum fittings and features of riveting are the same in the
cross drum as in the longitudinal types. The sections and mud drum are also
Page 75
the same for the two types.
Cross drum boilers are supported at the rear on the mud drum which rests on
cast-iron foundation plates. They are suspended at the front from a wrought-
iron supporting frame, each section being suspended independently from the
cross members by hook suspension bolts. This method of support is such as
to allow for expansion and contraction without straining either the boiler or
the brickwork and permits of repair or renewal of the latter without in any
way disturbing the boiler or its connections.
The following features of design
and of attachments supplied are
the same for all types.
FRONTS—Ornamental fronts are
fitted to the front supporting
frame. These have large doors for
access to the front headers and
panels above the fire fronts. The
fire fronts where furnished have
independent frames for fire doors
which are bolted on, and ashpit
doors fitted with blast catches. The
lugs on door frames and on doors
are cast solid. The faces of doors
and of frames are planed and the
lugs milled. The doors and frames Cross Drum Boiler Front
are placed in their final relative
position, clamped, and the holes
for hinge pins drilled while thus held. A perfect alignment of door and frame
is thus assured and the method is representative of the care taken in small
details of manufacture.
The front as a whole is so arranged that any stoker may be applied with but
slight modification wherever boilers are set with sufficient furnace height.
In the vertical header boilers large wrought-iron doors, which give access to
the rear headers, are attached to the rear supporting frame. [Pg 54]
Cross drum boilers are supported at the rear on the mud drum which rests on
cast-iron foundation plates. They are suspended at the front from a wrought-
iron supporting frame, each section being suspended independently from the
cross members by hook suspension bolts. This method of support is such as
to allow for expansion and contraction without straining either the boiler or
the brickwork and permits of repair or renewal of the latter without in any
way disturbing the boiler or its connections.
The following features of design
and of attachments supplied are
the same for all types.
FRONTS—Ornamental fronts are
fitted to the front supporting
frame. These have large doors for
access to the front headers and
panels above the fire fronts. The
fire fronts where furnished have
independent frames for fire doors
which are bolted on, and ashpit
doors fitted with blast catches. The
lugs on door frames and on doors
are cast solid. The faces of doors
and of frames are planed and the
lugs milled. The doors and frames Cross Drum Boiler Front
are placed in their final relative
position, clamped, and the holes
for hinge pins drilled while thus held. A perfect alignment of door and frame
is thus assured and the method is representative of the care taken in small
details of manufacture.
The front as a whole is so arranged that any stoker may be applied with but
slight modification wherever boilers are set with sufficient furnace height.
In the vertical header boilers large wrought-iron doors, which give access to
the rear headers, are attached to the rear supporting frame. [Pg 54]
Page 76
Wrought-steel Inclined Header Longitudinal Drum Babcock & Wilcox
Boiler, Equipped with Babcock & Wilcox Superheater
[Pg 55] FITTINGS—Each boiler is provided with the following fittings as part
of the standard equipment:
Blow-off connections and valves attached to the mud drum.
Safety valves placed on nozzles on the steam drums.
A water column connected to the front of the drum.
A steam gauge attached to the boiler front.
Boiler, Equipped with Babcock & Wilcox Superheater
[Pg 55] FITTINGS—Each boiler is provided with the following fittings as part
of the standard equipment:
Blow-off connections and valves attached to the mud drum.
Safety valves placed on nozzles on the steam drums.
A water column connected to the front of the drum.
A steam gauge attached to the boiler front.
Page 77
Feed water connection
and valves. A flanged
stop and check valve of
heavy pattern is attached
directly to each
drumhead, closing
automatically in case of a
Automatic Drumhead Stop and Check Valve rupture in the feed line.
All valves and fittings
are substantially built and are of designs which by their successful service
for many years have become standard with The Babcock & Wilcox Co.
The fixtures that are supplied with the boilers consist of:
Dead plates and supports, the plates arranged for a fire brick lining.
A full set of grate bars and bearers, the latter fitted with expansion sockets
for side walls.
Flame bridge plates with necessary fastenings, and special fire brick for
lining same.
Bridge wall girder for hanging bridge wall with expansion sockets for side
walls.
A full set of access and cleaning doors through which all portions of the
pressure parts may be reached.
A swing damper and frame with damper operating rig.
There are also supplied with each boiler a wrench for handhole nuts, a water-
driven turbine tube cleaner, a set of fire tools and a metal steam hose and
cleaning pipe equipped with a special nozzle for blowing dust and soot from
the tubes.
Aside from the details of design and construction as covered in the foregoing
description, a study of the illustrations will make clear the features of the
boiler as a whole which have led to its success.
and valves. A flanged
stop and check valve of
heavy pattern is attached
directly to each
drumhead, closing
automatically in case of a
Automatic Drumhead Stop and Check Valve rupture in the feed line.
All valves and fittings
are substantially built and are of designs which by their successful service
for many years have become standard with The Babcock & Wilcox Co.
The fixtures that are supplied with the boilers consist of:
Dead plates and supports, the plates arranged for a fire brick lining.
A full set of grate bars and bearers, the latter fitted with expansion sockets
for side walls.
Flame bridge plates with necessary fastenings, and special fire brick for
lining same.
Bridge wall girder for hanging bridge wall with expansion sockets for side
walls.
A full set of access and cleaning doors through which all portions of the
pressure parts may be reached.
A swing damper and frame with damper operating rig.
There are also supplied with each boiler a wrench for handhole nuts, a water-
driven turbine tube cleaner, a set of fire tools and a metal steam hose and
cleaning pipe equipped with a special nozzle for blowing dust and soot from
the tubes.
Aside from the details of design and construction as covered in the foregoing
description, a study of the illustrations will make clear the features of the
boiler as a whole which have led to its success.
Page 78
The method of supporting the boiler has been described. This allows it to be
hung at any height that may be necessary to properly handle the fuel to be
burned or to accommodate the stoker to be installed. The height of the nest
of tubes which forms the roof of the furnace is thus the controlling feature in
determining the furnace height, or the distance from the front headers to the
floor line. The sides and front of the furnace are formed by the side and front
boiler walls. The rear wall of the furnace consists of a bridge wall built from
the bottom of the ashpit to the lower row of tubes. The location of this wall
may be adjusted within limits to give the depth of furnace demanded by the
fuel used. Ordinarily the bridge wall is the determining feature in the
locating of the front baffle. Where a great depth of furnace is necessary, in
which case, if the front baffle were placed at the bridge wall the front pass of
the boiler would be relatively too long, a patented construction is used which
maintains the baffle in what may be considered its normal position, and a
connection made between the baffle and the bridge wall by means of a tile
roof. Such furnace construction is known as a “Webster” furnace. [Pg 56]
[Pg 57] A consideration of this furnace will clearly indicate its adaptability, by
reason of its flexibility, for any fuel and any design of stoker. The boiler
lends itself readily to installation with an extension or Dutch oven furnace if
this be demanded by the fuel to be used, and in general it may be stated that
a satisfactory furnace arrangement may be made in connection with a
Babcock & Wilcox boiler for burning any fuel, solid, liquid or gaseous.
hung at any height that may be necessary to properly handle the fuel to be
burned or to accommodate the stoker to be installed. The height of the nest
of tubes which forms the roof of the furnace is thus the controlling feature in
determining the furnace height, or the distance from the front headers to the
floor line. The sides and front of the furnace are formed by the side and front
boiler walls. The rear wall of the furnace consists of a bridge wall built from
the bottom of the ashpit to the lower row of tubes. The location of this wall
may be adjusted within limits to give the depth of furnace demanded by the
fuel used. Ordinarily the bridge wall is the determining feature in the
locating of the front baffle. Where a great depth of furnace is necessary, in
which case, if the front baffle were placed at the bridge wall the front pass of
the boiler would be relatively too long, a patented construction is used which
maintains the baffle in what may be considered its normal position, and a
connection made between the baffle and the bridge wall by means of a tile
roof. Such furnace construction is known as a “Webster” furnace. [Pg 56]
[Pg 57] A consideration of this furnace will clearly indicate its adaptability, by
reason of its flexibility, for any fuel and any design of stoker. The boiler
lends itself readily to installation with an extension or Dutch oven furnace if
this be demanded by the fuel to be used, and in general it may be stated that
a satisfactory furnace arrangement may be made in connection with a
Babcock & Wilcox boiler for burning any fuel, solid, liquid or gaseous.
Page 79
Longitudinal Drum Boiler—Front View
The gases of combustion evolved in the furnace above described are led over
the heating surfaces by two baffles. These are formed of cast-iron baffle
plates lined with special fire brick and held in position by tube clamps. The
front baffle leads the gases through the forward portion of the tubes to a
chamber beneath the drum or drums. It is in this chamber that a superheater
is installed where such an apparatus is desired. The gases make a turn over
the front baffle, are led downward through the central portion of the tubes,
called the second pass, by means of a hanging bridge wall of brick and the
second baffle, around which they make a second turn upward, pass through
the rear portion of the tubes and are led to the stack or flue through a damper
box in the rear wall, or around the drums to a damper box placed overhead.
The gases of combustion evolved in the furnace above described are led over
the heating surfaces by two baffles. These are formed of cast-iron baffle
plates lined with special fire brick and held in position by tube clamps. The
front baffle leads the gases through the forward portion of the tubes to a
chamber beneath the drum or drums. It is in this chamber that a superheater
is installed where such an apparatus is desired. The gases make a turn over
the front baffle, are led downward through the central portion of the tubes,
called the second pass, by means of a hanging bridge wall of brick and the
second baffle, around which they make a second turn upward, pass through
the rear portion of the tubes and are led to the stack or flue through a damper
box in the rear wall, or around the drums to a damper box placed overhead.
Page 80
The space beneath the tubes between the
bridge wall and the rear boiler wall forms a
pocket into which much of the soot from the
gases in their downward passage through the
second pass will be deposited and from
which it may be readily cleaned through
doors furnished for the purpose.
The gas passages are ample and are so
proportioned that the resistance offered to
the gases is only such as will assure the
proper abstraction of heat from the gases
without causing undue friction, requiring
excessive draft.
The method in which the feed water is
introduced through the front drumhead of
the boiler is clearly seen by reference to the
illustration. From this point of introduction
the water passes to the rear of the drum, Partial Vertical Section
downward through the rear circulating tubes Showing Method of
to the sections, upward through the tubes of Introducing Feed Water
the sections to the front headers and through
these headers and front circulating tubes
again to the drum where such water as has not been formed into steam
retraces its course. The steam formed in the passage through the tubes is
liberated as the water reaches the front of the drum. The steam so formed is
stored in the steam space above the water line, from which it is drawn
through a so-called “dry pipe.” The dry pipe in the Babcock & Wilcox boiler
is misnamed, as in reality it fulfills none of the functions ordinarily
attributed to such a device. This function is [Pg 58]
[Pg 59] usually to restrict the flow of steam from a boiler with a view to avoid
priming. In the Babcock & Wilcox boiler its function is simply that of a
collecting pipe, and as the aggregate area of the holes in it is greatly in
excess of the area of the steam outlet from the drum, it is plain that there can
be no restriction through this collecting pipe. It extends nearly the length of
the drum, and draws steam evenly from the whole length of the steam space.
bridge wall and the rear boiler wall forms a
pocket into which much of the soot from the
gases in their downward passage through the
second pass will be deposited and from
which it may be readily cleaned through
doors furnished for the purpose.
The gas passages are ample and are so
proportioned that the resistance offered to
the gases is only such as will assure the
proper abstraction of heat from the gases
without causing undue friction, requiring
excessive draft.
The method in which the feed water is
introduced through the front drumhead of
the boiler is clearly seen by reference to the
illustration. From this point of introduction
the water passes to the rear of the drum, Partial Vertical Section
downward through the rear circulating tubes Showing Method of
to the sections, upward through the tubes of Introducing Feed Water
the sections to the front headers and through
these headers and front circulating tubes
again to the drum where such water as has not been formed into steam
retraces its course. The steam formed in the passage through the tubes is
liberated as the water reaches the front of the drum. The steam so formed is
stored in the steam space above the water line, from which it is drawn
through a so-called “dry pipe.” The dry pipe in the Babcock & Wilcox boiler
is misnamed, as in reality it fulfills none of the functions ordinarily
attributed to such a device. This function is [Pg 58]
[Pg 59] usually to restrict the flow of steam from a boiler with a view to avoid
priming. In the Babcock & Wilcox boiler its function is simply that of a
collecting pipe, and as the aggregate area of the holes in it is greatly in
excess of the area of the steam outlet from the drum, it is plain that there can
be no restriction through this collecting pipe. It extends nearly the length of
the drum, and draws steam evenly from the whole length of the steam space.
Page 81
Cast-iron Vertical Header Longitudinal Drum Babcock & Wilcox Boiler
The large tube doors through which access is had to the front headers and the
doors giving such access to the rear headers in boilers of the vertical header
type have already been described and are shown clearly by the illustrations
on pages 56 and 74. In boilers of the inclined header type, access to the rear
headers is secured through the chamber formed by the headers and the rear
boiler wall. Large doors in the sides of the setting give full access to all parts
for inspection and for removal of accumulations of soot. Small dusting doors
are supplied for the side walls through which all of the heating surfaces may
be cleaned by means of a steam dusting lance. These side dusting doors are a
patented feature and the shutters are self closing. In wide boilers additional
cleaning doors are supplied at the top of the setting to insure ease in reaching
all portions of the heating surface.
The large tube doors through which access is had to the front headers and the
doors giving such access to the rear headers in boilers of the vertical header
type have already been described and are shown clearly by the illustrations
on pages 56 and 74. In boilers of the inclined header type, access to the rear
headers is secured through the chamber formed by the headers and the rear
boiler wall. Large doors in the sides of the setting give full access to all parts
for inspection and for removal of accumulations of soot. Small dusting doors
are supplied for the side walls through which all of the heating surfaces may
be cleaned by means of a steam dusting lance. These side dusting doors are a
patented feature and the shutters are self closing. In wide boilers additional
cleaning doors are supplied at the top of the setting to insure ease in reaching
all portions of the heating surface.
Page 82
The drums are accessible for inspection
through the manhole openings. The
removal of the handhole plates makes
possible the inspection of each tube for
its full length and gives the assurance
that no defect can exist that cannot be
actually seen. This is particularly
advantageous when inspecting for the
presence of scale.
The materials entering into the
construction of the Babcock & Wilcox
boiler are the best obtainable for the
special purpose for which they are used
and are subjected to rigid inspection and
tests.
The boilers are manufactured by means
Closed Open of the most modern shop equipment and
appliances in the hands of an old and
well-tried organization of skilled
Patented Side Dusting Doors mechanics under the supervision of
experienced engineers. [Pg 60]
through the manhole openings. The
removal of the handhole plates makes
possible the inspection of each tube for
its full length and gives the assurance
that no defect can exist that cannot be
actually seen. This is particularly
advantageous when inspecting for the
presence of scale.
The materials entering into the
construction of the Babcock & Wilcox
boiler are the best obtainable for the
special purpose for which they are used
and are subjected to rigid inspection and
tests.
The boilers are manufactured by means
Closed Open of the most modern shop equipment and
appliances in the hands of an old and
well-tried organization of skilled
Patented Side Dusting Doors mechanics under the supervision of
experienced engineers. [Pg 60]
Page 83
Cast-iron Vertical Header Cross Drum Babcock & Wilcox Boiler
Page 84
[Pg 61]
Page 85
ADVANTAGES OF THE BABCOCK & WILCOX
BOILER
The advantages of the Babcock & Wilcox boiler may perhaps be most
clearly set forth by a consideration, 1st, of water-tube boilers as a class as
compared with shell and fire-tube boilers; and 2nd, of the Babcock &
Wilcox boiler specifically as compared with other designs of water-tube
boilers.
WATER-TUBE VERSUS FIRE-TUBE BOILERS
Safety—The most important requirement of a steam boiler is that it shall be
safe in so far as danger from explosion is concerned. If the energy in a large
shell boiler under pressure is considered, the thought of the destruction
possible in the case of an explosion is appalling. The late Dr. Robert H.
Thurston, Dean of Sibley College, Cornell University, and past president of
the American Society of Mechanical Engineers, estimated that there is
sufficient energy stored in a plain cylinder boiler under 100 pounds steam
pressure to project it in case of an explosion to a height of over 3½ miles; a
locomotive boiler at 125 pounds pressure from one-half to one-third of a
mile; and a 60 horse-power return tubular boiler under 75 pounds pressure
somewhat over a mile. To quote: “A cubic foot of heated water under a
pressure of from 60 to 70 pounds per square inch has about the same energy
as one pound of gunpowder.” From such a consideration, it may be readily
appreciated how the advent of high pressure steam was one of the strongest
factors in forcing the adoption of water-tube boilers. A consideration of the
thickness of material necessary for cylinders of various diameters under a
steam pressure of 200 pounds and assuming an allowable stress of 12,000
pounds per square inch, will perhaps best illustrate this point. Table 1 gives
such thicknesses for various diameters of cylinders not taking into
consideration the weakening effect of any joints which may be necessary.
The rapidity with which the plate thickness increases with the diameter is
apparent and in practice, due to the fact that riveted joints must be used, the
BOILER
The advantages of the Babcock & Wilcox boiler may perhaps be most
clearly set forth by a consideration, 1st, of water-tube boilers as a class as
compared with shell and fire-tube boilers; and 2nd, of the Babcock &
Wilcox boiler specifically as compared with other designs of water-tube
boilers.
WATER-TUBE VERSUS FIRE-TUBE BOILERS
Safety—The most important requirement of a steam boiler is that it shall be
safe in so far as danger from explosion is concerned. If the energy in a large
shell boiler under pressure is considered, the thought of the destruction
possible in the case of an explosion is appalling. The late Dr. Robert H.
Thurston, Dean of Sibley College, Cornell University, and past president of
the American Society of Mechanical Engineers, estimated that there is
sufficient energy stored in a plain cylinder boiler under 100 pounds steam
pressure to project it in case of an explosion to a height of over 3½ miles; a
locomotive boiler at 125 pounds pressure from one-half to one-third of a
mile; and a 60 horse-power return tubular boiler under 75 pounds pressure
somewhat over a mile. To quote: “A cubic foot of heated water under a
pressure of from 60 to 70 pounds per square inch has about the same energy
as one pound of gunpowder.” From such a consideration, it may be readily
appreciated how the advent of high pressure steam was one of the strongest
factors in forcing the adoption of water-tube boilers. A consideration of the
thickness of material necessary for cylinders of various diameters under a
steam pressure of 200 pounds and assuming an allowable stress of 12,000
pounds per square inch, will perhaps best illustrate this point. Table 1 gives
such thicknesses for various diameters of cylinders not taking into
consideration the weakening effect of any joints which may be necessary.
The rapidity with which the plate thickness increases with the diameter is
apparent and in practice, due to the fact that riveted joints must be used, the
Page 86
thicknesses as given in the table, with the exception of the first, must be
increased from 30 to 40 per cent.
In a water-tube boiler the drums seldom exceed 48 inches in diameter and
the thickness of plate required, therefore, is never excessive. The thinner
metal can be rolled to a more uniform quality, the seams admit of better
proportioning, and the joints can be more easily and perfectly fitted than is
the case where thicker plates are necessary. All of these points contribute
toward making the drums of water-tube boilers better able to withstand the
stress which they will be called upon to endure.
The essential constructive difference between water-tube and fire-tube
boilers lies in the fact that the former is composed of parts of relatively small
diameter as against the large diameters necessary in the latter.
The factor of safety of the boiler parts which come in contact with the most
intense heat in water-tube boilers can be made much higher than would be
practicable in a shell boiler. Under the assumptions considered above in
connection with the thickness of plates required, a number 10 gauge tube
(0.134 inch), which is standard in Babcock & Wilcox boilers for pressures
up to 210 pounds under the same allowable stress as was used in computing
Table 1, the safe working pressure for the tubes is 870 pounds per square
inch, indicating the very large margin of safety of such tubes as compared
with that possible with the shell of a boiler.
[Pg 62]
TABLE 1 A further advantage in the
water-tube boiler as a class is
PLATE THICKNESS REQUIRED FOR the elimination of all
VARIOUS CYLINDER DIAMETERS compressive stresses.
Cylinders subjected to
ALLOWABLE STRESS, 12000 external pressures, such as
POUNDS fire tubes or the internally
PER SQUARE INCH, 200 POUNDS fired furnaces of certain types
GAUGE PRESSURE, NO JOINTS of boilers, will collapse under
Diameter Thickness Diameter Thickness a pressure much lower than
Inches Inches Inches Inches that which they could
increased from 30 to 40 per cent.
In a water-tube boiler the drums seldom exceed 48 inches in diameter and
the thickness of plate required, therefore, is never excessive. The thinner
metal can be rolled to a more uniform quality, the seams admit of better
proportioning, and the joints can be more easily and perfectly fitted than is
the case where thicker plates are necessary. All of these points contribute
toward making the drums of water-tube boilers better able to withstand the
stress which they will be called upon to endure.
The essential constructive difference between water-tube and fire-tube
boilers lies in the fact that the former is composed of parts of relatively small
diameter as against the large diameters necessary in the latter.
The factor of safety of the boiler parts which come in contact with the most
intense heat in water-tube boilers can be made much higher than would be
practicable in a shell boiler. Under the assumptions considered above in
connection with the thickness of plates required, a number 10 gauge tube
(0.134 inch), which is standard in Babcock & Wilcox boilers for pressures
up to 210 pounds under the same allowable stress as was used in computing
Table 1, the safe working pressure for the tubes is 870 pounds per square
inch, indicating the very large margin of safety of such tubes as compared
with that possible with the shell of a boiler.
[Pg 62]
TABLE 1 A further advantage in the
water-tube boiler as a class is
PLATE THICKNESS REQUIRED FOR the elimination of all
VARIOUS CYLINDER DIAMETERS compressive stresses.
Cylinders subjected to
ALLOWABLE STRESS, 12000 external pressures, such as
POUNDS fire tubes or the internally
PER SQUARE INCH, 200 POUNDS fired furnaces of certain types
GAUGE PRESSURE, NO JOINTS of boilers, will collapse under
Diameter Thickness Diameter Thickness a pressure much lower than
Inches Inches Inches Inches that which they could
Page 87
4 0.033 72 0.600 withstand if it were applied
36 0.300 108 0.900 internally. This is due to the
48 0.400 120 1.000 fact that if there exists any
60 0.500 144 1.200 initial distortion from its true
shape, the external pressure
will tend to increase such distortion and collapse the cylinder, while an
internal pressure tends to restore the cylinder to its original shape.
Stresses due to unequal expansion have been a fruitful source of trouble in
fire-tube boilers.
In boilers of the shell type, the riveted joints of the shell, with their
consequent double thickness of metal exposed to the fire, gives rise to
serious difficulties. Upon these points are concentrated all strains of unequal
expansion, giving rise to frequent leaks and oftentimes to actual ruptures.
Moreover, in the case of such rupture, the whole body of contained water is
liberated instantaneously and a disastrous and usually fatal explosion results.
Further, unequal strains result in shell or fire-tube boilers due to the
difference in temperature of the various parts. This difference in temperature
results from the lack of positive well defined circulation. While such a
circulation does not necessarily accompany all water-tube designs, in
general, the circulation in water-tube boilers is much more defined than in
fire-tube or shell boilers.
A positive and efficient circulation assures that all portions of the pressure
parts will be at approximately the same temperature and in this way strains
resulting from unequal temperatures are obviated.
If a shell or fire-tubular boiler explodes, the apparatus as a whole is
destroyed. In the case of water-tube boilers, the drums are ordinarily so
located that they are protected from intense heat and any rupture is usually in
the case of a tube. Tube failures, resulting from blisters or burning, are not
serious in their nature. Where a tube ruptures because of a flaw in the metal,
the result may be more severe, but there cannot be the disastrous explosion
such as would occur in the case of the explosion of a shell boiler.
36 0.300 108 0.900 internally. This is due to the
48 0.400 120 1.000 fact that if there exists any
60 0.500 144 1.200 initial distortion from its true
shape, the external pressure
will tend to increase such distortion and collapse the cylinder, while an
internal pressure tends to restore the cylinder to its original shape.
Stresses due to unequal expansion have been a fruitful source of trouble in
fire-tube boilers.
In boilers of the shell type, the riveted joints of the shell, with their
consequent double thickness of metal exposed to the fire, gives rise to
serious difficulties. Upon these points are concentrated all strains of unequal
expansion, giving rise to frequent leaks and oftentimes to actual ruptures.
Moreover, in the case of such rupture, the whole body of contained water is
liberated instantaneously and a disastrous and usually fatal explosion results.
Further, unequal strains result in shell or fire-tube boilers due to the
difference in temperature of the various parts. This difference in temperature
results from the lack of positive well defined circulation. While such a
circulation does not necessarily accompany all water-tube designs, in
general, the circulation in water-tube boilers is much more defined than in
fire-tube or shell boilers.
A positive and efficient circulation assures that all portions of the pressure
parts will be at approximately the same temperature and in this way strains
resulting from unequal temperatures are obviated.
If a shell or fire-tubular boiler explodes, the apparatus as a whole is
destroyed. In the case of water-tube boilers, the drums are ordinarily so
located that they are protected from intense heat and any rupture is usually in
the case of a tube. Tube failures, resulting from blisters or burning, are not
serious in their nature. Where a tube ruptures because of a flaw in the metal,
the result may be more severe, but there cannot be the disastrous explosion
such as would occur in the case of the explosion of a shell boiler.
Page 88
To quote Dr. Thurston, relative to the greater safety of the water-tube boiler:
“The stored available energy is usually less than that of any of the other
stationary boilers and not very far from the amount stored, pound for pound,
in the plain tubular boiler. It is evident that their admitted safety from
destructive explosion does not come from this relation, however, but from
the division of the contents into small portions and especially from those
details of construction which make it tolerably certain that any rupture shall
be local. A violent explosion can only come from the general disruption of a
boiler and the liberation at once of large masses of steam and water.”
Economy—The requirement probably next in importance to safety in a steam
boiler is economy in the use of fuel. To fulfill such a requirement, the three
items, of [Pg 63] proper grate for the class of fuel to be burned, a combustion
chamber permitting complete combustion of gases before their escape to the
stack, and the heating surface of such a character and arrangement that the
maximum amount of available heat may be extracted, must be co-ordinated.
Fire-tube boilers from the nature of their design do not permit the variety of
combinations of grate surface, heating surface, and combustion space
possible in practically any water-tube boiler.
In securing the best results in fuel economy, the draft area in a boiler is an
important consideration. In fire-tube boilers this area is limited to the cross
sectional area of the fire tubes, a condition further aggravated in a horizontal
boiler by the tendency of the hot gases to pass through the upper rows of
tubes instead of through all of the tubes alike. In water-tube boilers the draft
area is that of the space outside of the tubes and is hence much greater than
the cross sectional area of the tubes.
Capacity—Due to the generally more efficient circulation found in water-
tube than in fire-tube boilers, rates of evaporation are possible with water-
tube boilers that cannot be approached where fire-tube boilers are employed.
Quick Steaming—Another important result of the better circulation
ordinarily found in water-tube boilers is in their ability to raise steam rapidly
in starting and to meet the sudden demands that may be thrown on them.
“The stored available energy is usually less than that of any of the other
stationary boilers and not very far from the amount stored, pound for pound,
in the plain tubular boiler. It is evident that their admitted safety from
destructive explosion does not come from this relation, however, but from
the division of the contents into small portions and especially from those
details of construction which make it tolerably certain that any rupture shall
be local. A violent explosion can only come from the general disruption of a
boiler and the liberation at once of large masses of steam and water.”
Economy—The requirement probably next in importance to safety in a steam
boiler is economy in the use of fuel. To fulfill such a requirement, the three
items, of [Pg 63] proper grate for the class of fuel to be burned, a combustion
chamber permitting complete combustion of gases before their escape to the
stack, and the heating surface of such a character and arrangement that the
maximum amount of available heat may be extracted, must be co-ordinated.
Fire-tube boilers from the nature of their design do not permit the variety of
combinations of grate surface, heating surface, and combustion space
possible in practically any water-tube boiler.
In securing the best results in fuel economy, the draft area in a boiler is an
important consideration. In fire-tube boilers this area is limited to the cross
sectional area of the fire tubes, a condition further aggravated in a horizontal
boiler by the tendency of the hot gases to pass through the upper rows of
tubes instead of through all of the tubes alike. In water-tube boilers the draft
area is that of the space outside of the tubes and is hence much greater than
the cross sectional area of the tubes.
Capacity—Due to the generally more efficient circulation found in water-
tube than in fire-tube boilers, rates of evaporation are possible with water-
tube boilers that cannot be approached where fire-tube boilers are employed.
Quick Steaming—Another important result of the better circulation
ordinarily found in water-tube boilers is in their ability to raise steam rapidly
in starting and to meet the sudden demands that may be thrown on them.
Page 89
In a properly designed water-tube boiler steam may be raised from a cold
boiler to 200 pounds pressure in less than one-half hour.
For the sake of comparison with the figure above, it may be stated that in the
U. S. Government Service the shortest time allowed for getting up steam in
Scotch marine boilers is 6 hours and the time ordinarily allowed is 12 hours.
In large double-ended Scotch boilers, such as are generally used in Trans-
Atlantic service, the fires are usually started 24 hours before the time set for
getting under way. This length of time is necessary for such boilers in order
to eliminate as far as possible excessive strains resulting from the sudden
application of heat to the surfaces.
Accessibility—In the “Requirements of a Perfect Steam Boiler”, as stated
by Mr. Babcock, he demonstrates the necessity for complete accessibility to
all portions of the boiler for cleaning, inspection and repair.
Cleaning—When the great difference is realized in performance, both as to
economy and capacity of a clean boiler and one in which the heating
surfaces have been allowed to become fouled, it may be appreciated that the
ability to keep heating surfaces clean internally and externally is a factor of
the highest importance.
Such results can be accomplished only by the use of a design in boiler
construction which gives complete accessibility to all portions. In fire-tube
boilers the tubes are frequently nested together with a space between them
often less than 1¼ inches and, as a consequence, nearly the entire tube
surface is inaccessible. When scale forms upon such tubes it is impossible to
remove it completely from the inside of the boiler and if it is removed by a
turbine hammer, there is no way of knowing how thorough a job has been
done. With the formation of such scale there is danger through overheating
and frequent tube renewals are necessary.
In Scotch marine boilers, even with the engines operating condensing,
complete tube renewals at intervals of six or seven years are required, while
large replacements are often necessary in less than one year. In return tubular
boilers operated with bad feed water, complete tube renewals annually are
not uncommon. In this type of boiler [Pg 64]
[Pg 65] much sediment falls on the bottom sheets where the intense heat to
boiler to 200 pounds pressure in less than one-half hour.
For the sake of comparison with the figure above, it may be stated that in the
U. S. Government Service the shortest time allowed for getting up steam in
Scotch marine boilers is 6 hours and the time ordinarily allowed is 12 hours.
In large double-ended Scotch boilers, such as are generally used in Trans-
Atlantic service, the fires are usually started 24 hours before the time set for
getting under way. This length of time is necessary for such boilers in order
to eliminate as far as possible excessive strains resulting from the sudden
application of heat to the surfaces.
Accessibility—In the “Requirements of a Perfect Steam Boiler”, as stated
by Mr. Babcock, he demonstrates the necessity for complete accessibility to
all portions of the boiler for cleaning, inspection and repair.
Cleaning—When the great difference is realized in performance, both as to
economy and capacity of a clean boiler and one in which the heating
surfaces have been allowed to become fouled, it may be appreciated that the
ability to keep heating surfaces clean internally and externally is a factor of
the highest importance.
Such results can be accomplished only by the use of a design in boiler
construction which gives complete accessibility to all portions. In fire-tube
boilers the tubes are frequently nested together with a space between them
often less than 1¼ inches and, as a consequence, nearly the entire tube
surface is inaccessible. When scale forms upon such tubes it is impossible to
remove it completely from the inside of the boiler and if it is removed by a
turbine hammer, there is no way of knowing how thorough a job has been
done. With the formation of such scale there is danger through overheating
and frequent tube renewals are necessary.
In Scotch marine boilers, even with the engines operating condensing,
complete tube renewals at intervals of six or seven years are required, while
large replacements are often necessary in less than one year. In return tubular
boilers operated with bad feed water, complete tube renewals annually are
not uncommon. In this type of boiler [Pg 64]
[Pg 65] much sediment falls on the bottom sheets where the intense heat to
Page 90
which they are subjected bakes it to such an excessive hardness that the only
method of removing it is to chisel it out. This can be done only by omitting
tubes enough to leave a space into which a man can crawl and the
discomforts under which he must work are apparent. Unless such a deposit is
removed, a burned and buckled plate will invariably result, and if neglected
too long an explosion will follow.
Portion of 29,000 Horse-power Installation of Babcock & Wilcox Boilers
in the L Street Station of the Edison Electric Illuminating Co. of Boston,
Mass. This Company Operates in its Various Stations a Total of 39,000
Horse Power of Babcock & Wilcox Boilers
In vertical fire-tube boilers using a water leg construction, a deposit of mud
in such legs is an active agent in causing corrosion and the difficulty of
removing such deposit through handholes is well known. A complete
removal is practically impossible and as a last resort to obviate corrosion in
certain designs, the bottom of the water legs in some cases have been made
of copper. A thick layer of mud and scale is also liable to accumulate on the
crown sheet of such boilers and may cause the sheet to crack and lead to an
explosion.
method of removing it is to chisel it out. This can be done only by omitting
tubes enough to leave a space into which a man can crawl and the
discomforts under which he must work are apparent. Unless such a deposit is
removed, a burned and buckled plate will invariably result, and if neglected
too long an explosion will follow.
Portion of 29,000 Horse-power Installation of Babcock & Wilcox Boilers
in the L Street Station of the Edison Electric Illuminating Co. of Boston,
Mass. This Company Operates in its Various Stations a Total of 39,000
Horse Power of Babcock & Wilcox Boilers
In vertical fire-tube boilers using a water leg construction, a deposit of mud
in such legs is an active agent in causing corrosion and the difficulty of
removing such deposit through handholes is well known. A complete
removal is practically impossible and as a last resort to obviate corrosion in
certain designs, the bottom of the water legs in some cases have been made
of copper. A thick layer of mud and scale is also liable to accumulate on the
crown sheet of such boilers and may cause the sheet to crack and lead to an
explosion.
Page 91
The soot and fine coal swept along with the gases by the draft will settle in
fire tubes and unless removed promptly, must be cut out with a special form
of scraper. It is not unusual where soft coal is used to find tubes half filled
with soot, which renders useless a large portion of the heating surface and so
restricts the draft as to make it difficult to burn sufficient coal to develop the
required power from such heating surface as is not covered by soot.
Water-tube boilers in general are from the nature of their design more readily
accessible for cleaning than are fire-tube boilers.
Inspection—The objections given above in the consideration of the inability
to properly clean fire-tube boilers hold as well for the inspection of such
boilers.
Repairs—The lack of accessibility in fire-tube boilers further leads to
difficulties where repairs are required.
In fire-tube boilers tube renewals are a serious undertaking. The
accumulation of hard deposit on the exterior of the surfaces so enlarges the
tubes that it is oftentimes difficult, if not impossible, to draw them through
the tube sheets and it is usually necessary to cut out such tubes as will allow
access to the one which has failed and remove them through the manhole.
When a tube sheet blisters, the defective part must be cut out by hand-tapped
holes drilled by ratchets and as it is frequently impossible to get space in
which to drive rivets, a “soft patch” is necessary. This is but a makeshift at
best and usually results in either a reduction of the safe working pressure or
in the necessity for a new plate. If the latter course is followed, the old plate
must be cut out, a new one scribed to place to locate rivet holes and in order
to obtain room for driving rivets, the boiler will have to be re-tubed.
The setting must, of course, be at least partially torn out and replaced.
In case of repairs, of such nature in fire-tube boilers, the working pressure of
such repaired boilers will frequently be lowered by the insurance companies
when the boiler is again placed in service.
In the case of a rupture in a water-tube boiler, the loss will ordinarily be
limited to one or two tubes which can be readily replaced. The fire-tube
fire tubes and unless removed promptly, must be cut out with a special form
of scraper. It is not unusual where soft coal is used to find tubes half filled
with soot, which renders useless a large portion of the heating surface and so
restricts the draft as to make it difficult to burn sufficient coal to develop the
required power from such heating surface as is not covered by soot.
Water-tube boilers in general are from the nature of their design more readily
accessible for cleaning than are fire-tube boilers.
Inspection—The objections given above in the consideration of the inability
to properly clean fire-tube boilers hold as well for the inspection of such
boilers.
Repairs—The lack of accessibility in fire-tube boilers further leads to
difficulties where repairs are required.
In fire-tube boilers tube renewals are a serious undertaking. The
accumulation of hard deposit on the exterior of the surfaces so enlarges the
tubes that it is oftentimes difficult, if not impossible, to draw them through
the tube sheets and it is usually necessary to cut out such tubes as will allow
access to the one which has failed and remove them through the manhole.
When a tube sheet blisters, the defective part must be cut out by hand-tapped
holes drilled by ratchets and as it is frequently impossible to get space in
which to drive rivets, a “soft patch” is necessary. This is but a makeshift at
best and usually results in either a reduction of the safe working pressure or
in the necessity for a new plate. If the latter course is followed, the old plate
must be cut out, a new one scribed to place to locate rivet holes and in order
to obtain room for driving rivets, the boiler will have to be re-tubed.
The setting must, of course, be at least partially torn out and replaced.
In case of repairs, of such nature in fire-tube boilers, the working pressure of
such repaired boilers will frequently be lowered by the insurance companies
when the boiler is again placed in service.
In the case of a rupture in a water-tube boiler, the loss will ordinarily be
limited to one or two tubes which can be readily replaced. The fire-tube
Page 92
boiler will be so completely demolished that the question of repairs will be
shifted from the boiler to the surrounding property, the damage to which will
usually exceed many times the cost of a boiler of a type which would have
eliminated the possibility of a disastrous explosion. In considering the proper
repair cost of the two types of boilers, the fact [Pg 66] should not be
overlooked that it is poor economy to invest large sums in equipment that,
through a possible accident to the boiler may be wholly destroyed or so
damaged that the cost of repairs, together with the loss of time while such
repairs are being made, would purchase boilers of absolute safety and leave
a large margin beside. The possibility of loss of human life should also be
considered, though this may seem a far cry from the question of repair costs.
TABLE 2 Space Occupied—
The space required
COMPARATIVE APPROXIMATE FLOOR for the boilers in a
SPACE OCCUPIED BY BABCOCK & WILCOX plant often exceeds
AND H. R. T. BOILERS the requirements for
Size of unit Babcock & Wilcox H. R. T. the remainder of the
Horse Power Feet and Inches Feet and Inches plant equipment.
100 7 3 × 19 9 10 0 × 20 0 Any saving of space
150 7 10 × 19 9 10 0 × 22 6 in a boiler room will
be a large factor in
200 9 0 × 19 9 11 6 × 23 10
reducing the cost of
250 9 0 × 19 9 11 6 × 23 10 real estate and of the
300 10 2 × 19 9 12 0 × 25 0 building. Even when
the boiler plant is
comparatively small, the saving in space frequently will amount to a
considerable percentage of the cost of the boilers. Table 2 shows the
difference in floor space occupied by fire-tube boilers and Babcock &
Wilcox boilers of the same capacity, the latter being taken as representing
the water-tube class. This saving in space will increase with the size of the
plant for the reason that large size boiler units while common in water-tube
practice are impracticable in fire-tube practice.
BABCOCK & WILCOX BOILERS AS COMPARED WITH
OTHER WATER-TUBE DESIGNS
shifted from the boiler to the surrounding property, the damage to which will
usually exceed many times the cost of a boiler of a type which would have
eliminated the possibility of a disastrous explosion. In considering the proper
repair cost of the two types of boilers, the fact [Pg 66] should not be
overlooked that it is poor economy to invest large sums in equipment that,
through a possible accident to the boiler may be wholly destroyed or so
damaged that the cost of repairs, together with the loss of time while such
repairs are being made, would purchase boilers of absolute safety and leave
a large margin beside. The possibility of loss of human life should also be
considered, though this may seem a far cry from the question of repair costs.
TABLE 2 Space Occupied—
The space required
COMPARATIVE APPROXIMATE FLOOR for the boilers in a
SPACE OCCUPIED BY BABCOCK & WILCOX plant often exceeds
AND H. R. T. BOILERS the requirements for
Size of unit Babcock & Wilcox H. R. T. the remainder of the
Horse Power Feet and Inches Feet and Inches plant equipment.
100 7 3 × 19 9 10 0 × 20 0 Any saving of space
150 7 10 × 19 9 10 0 × 22 6 in a boiler room will
be a large factor in
200 9 0 × 19 9 11 6 × 23 10
reducing the cost of
250 9 0 × 19 9 11 6 × 23 10 real estate and of the
300 10 2 × 19 9 12 0 × 25 0 building. Even when
the boiler plant is
comparatively small, the saving in space frequently will amount to a
considerable percentage of the cost of the boilers. Table 2 shows the
difference in floor space occupied by fire-tube boilers and Babcock &
Wilcox boilers of the same capacity, the latter being taken as representing
the water-tube class. This saving in space will increase with the size of the
plant for the reason that large size boiler units while common in water-tube
practice are impracticable in fire-tube practice.
BABCOCK & WILCOX BOILERS AS COMPARED WITH
OTHER WATER-TUBE DESIGNS
Page 93
It must be borne in mind that the simple fact that a boiler is of the water-tube
design does not as a necessity indicate that it is a good or safe boiler.
Safety—Many of the water-tube boilers on the market are as lacking as are
fire-tube boilers in the positive circulation which, as has been demonstrated
by Mr. Babcock’s lecture, is so necessary in the requirements of the perfect
steam boiler. In boilers using water-leg construction, there is danger of
defective circulation, leaks are common, and unsuspected corrosion may be
going on in portions of the boiler that cannot be inspected. Stresses due to
unequal expansion of the metal cannot be well avoided but they may be
minimized by maintaining at the same temperature all pressure parts of the
boiler. The result is to be secured only by means of a well defined
circulation.
The main feature to which the Babcock & Wilcox boiler owes its safety is
the construction made possible by the use of headers, by which the water in
each vertical row of tubes is separated from that in the adjacent rows. This
construction results in the very efficient circulation produced through the
breaking up of the steam and water in the front headers, the effect of these
headers in producing such a positive circulation having been clearly
demonstrated in Mr. Babcock’s lecture. The use of a number of sections,
thus composed of headers and tubes, has a distinct advantage over the use of
a common chamber at the outlet ends of the tubes. In the former case the
circulation of water in one vertical row of tubes cannot interfere with that in
the other rows, [Pg 67] while in the latter construction there will be downward
as well as upward currents and such downward currents tend to neutralize
any good effect there might be through the diminution of the density of the
water column by the steam.
Further, the circulation results directly from the design of the boiler and
requires no assistance from “retarders”, check valves and the like, within the
boiler. All such mechanical devices in the interior of a boiler serve only to
complicate the design and should not be used.
This positive and efficient circulation assures that all portions of the pressure
parts of the Babcock & Wilcox boiler will be at approximately the same
temperature and in this way strains resulting from unequal temperatures are
obviated.
design does not as a necessity indicate that it is a good or safe boiler.
Safety—Many of the water-tube boilers on the market are as lacking as are
fire-tube boilers in the positive circulation which, as has been demonstrated
by Mr. Babcock’s lecture, is so necessary in the requirements of the perfect
steam boiler. In boilers using water-leg construction, there is danger of
defective circulation, leaks are common, and unsuspected corrosion may be
going on in portions of the boiler that cannot be inspected. Stresses due to
unequal expansion of the metal cannot be well avoided but they may be
minimized by maintaining at the same temperature all pressure parts of the
boiler. The result is to be secured only by means of a well defined
circulation.
The main feature to which the Babcock & Wilcox boiler owes its safety is
the construction made possible by the use of headers, by which the water in
each vertical row of tubes is separated from that in the adjacent rows. This
construction results in the very efficient circulation produced through the
breaking up of the steam and water in the front headers, the effect of these
headers in producing such a positive circulation having been clearly
demonstrated in Mr. Babcock’s lecture. The use of a number of sections,
thus composed of headers and tubes, has a distinct advantage over the use of
a common chamber at the outlet ends of the tubes. In the former case the
circulation of water in one vertical row of tubes cannot interfere with that in
the other rows, [Pg 67] while in the latter construction there will be downward
as well as upward currents and such downward currents tend to neutralize
any good effect there might be through the diminution of the density of the
water column by the steam.
Further, the circulation results directly from the design of the boiler and
requires no assistance from “retarders”, check valves and the like, within the
boiler. All such mechanical devices in the interior of a boiler serve only to
complicate the design and should not be used.
This positive and efficient circulation assures that all portions of the pressure
parts of the Babcock & Wilcox boiler will be at approximately the same
temperature and in this way strains resulting from unequal temperatures are
obviated.
Page 94
Where the water throughout the boiler is at the temperature of the steam
contained, a condition to be secured only by proper circulation, danger from
internal pitting is minimized, or at least limited only to effects of the water
fed the boiler. Where the water in any portion of the boiler is lower than the
temperature of the steam corresponding to the pressure carried, whether the
fact that such lower temperatures exist as a result of lack of circulation, or
because of intentional design, internal pitting or corrosion will almost
invariably result.
Dr. Thurston has already been quoted to the effect that the admitted safety of
a water-tube boiler is the result of the division of its contents into small
portions. In boilers using a water-leg construction, while the danger from
explosion will be largely limited to the tubes, there is the danger, however,
that such legs may explode due to the deterioration of their stays, and such
an explosion might be almost as disastrous as that of a shell boiler. The
headers in a Babcock & Wilcox boiler are practically free from any danger
of explosion. Were such an explosion to occur, it would still be localized to a
much larger extent than in the case of a water-leg boiler and the header
construction thus almost absolutely localizes any danger from such a cause.
Staybolts are admittedly an undesirable element of construction in any
boiler. They are wholly objectionable and the only reason for the presence of
staybolts in a boiler is to enable a cheaper form of construction to be used
than if they were eliminated.
In boilers utilizing in their design flat-stayed surfaces, or staybolt
construction under pressure, corrosion and wear and tear in service tends to
weaken some single part subject to continual strain, the result being an
increased strain on other parts greatly in excess of that for which an
allowance can be made by any reasonable factor of safety. Where the
construction is such that the weakening of a single part will produce a
marked decrease in the safety and reliability of the whole, it follows of
necessity, that there will be a corresponding decrease in the working pressure
which may be safely carried.
In water-leg boilers, the use of such flat-stayed surfaces under pressure
presents difficulties that are practically unsurmountable. Such surfaces
exposed to the heat of the fire are subject to unequal expansion, distortion,
contained, a condition to be secured only by proper circulation, danger from
internal pitting is minimized, or at least limited only to effects of the water
fed the boiler. Where the water in any portion of the boiler is lower than the
temperature of the steam corresponding to the pressure carried, whether the
fact that such lower temperatures exist as a result of lack of circulation, or
because of intentional design, internal pitting or corrosion will almost
invariably result.
Dr. Thurston has already been quoted to the effect that the admitted safety of
a water-tube boiler is the result of the division of its contents into small
portions. In boilers using a water-leg construction, while the danger from
explosion will be largely limited to the tubes, there is the danger, however,
that such legs may explode due to the deterioration of their stays, and such
an explosion might be almost as disastrous as that of a shell boiler. The
headers in a Babcock & Wilcox boiler are practically free from any danger
of explosion. Were such an explosion to occur, it would still be localized to a
much larger extent than in the case of a water-leg boiler and the header
construction thus almost absolutely localizes any danger from such a cause.
Staybolts are admittedly an undesirable element of construction in any
boiler. They are wholly objectionable and the only reason for the presence of
staybolts in a boiler is to enable a cheaper form of construction to be used
than if they were eliminated.
In boilers utilizing in their design flat-stayed surfaces, or staybolt
construction under pressure, corrosion and wear and tear in service tends to
weaken some single part subject to continual strain, the result being an
increased strain on other parts greatly in excess of that for which an
allowance can be made by any reasonable factor of safety. Where the
construction is such that the weakening of a single part will produce a
marked decrease in the safety and reliability of the whole, it follows of
necessity, that there will be a corresponding decrease in the working pressure
which may be safely carried.
In water-leg boilers, the use of such flat-stayed surfaces under pressure
presents difficulties that are practically unsurmountable. Such surfaces
exposed to the heat of the fire are subject to unequal expansion, distortion,
Page 95
leakage and corrosion, or in general, to many of the objections that have
already been advanced against the fire-tube boilers in the consideration of
water-tube boilers as a class in comparison with fire-tube boilers.
Aside from the difficulties that may arise in actual service due to the failure
of staybolts, or in general, due to the use of flat-stayed surfaces,
constructional features are encountered in the actual manufacture of such
boilers that make it difficult if not [Pg 68]
[Pg 69] impossible to produce a first-class mechanical job. It is practically
impossible in the building of such a boiler to so design and place the
staybolts that all will be under equal strain. Such unequal strains, resulting
from constructional difficulties, will be greatly multiplied when such a boiler
is placed in service. Much of the riveting in boilers of this design must of
necessity be hand work, which is never the equal of machine riveting. The
use of water-leg construction ordinarily requires the flanging of large plates,
which is difficult, and because of the number of heats necessary and the
continual working of the material, may lead to the weakening of such plates.
already been advanced against the fire-tube boilers in the consideration of
water-tube boilers as a class in comparison with fire-tube boilers.
Aside from the difficulties that may arise in actual service due to the failure
of staybolts, or in general, due to the use of flat-stayed surfaces,
constructional features are encountered in the actual manufacture of such
boilers that make it difficult if not [Pg 68]
[Pg 69] impossible to produce a first-class mechanical job. It is practically
impossible in the building of such a boiler to so design and place the
staybolts that all will be under equal strain. Such unequal strains, resulting
from constructional difficulties, will be greatly multiplied when such a boiler
is placed in service. Much of the riveting in boilers of this design must of
necessity be hand work, which is never the equal of machine riveting. The
use of water-leg construction ordinarily requires the flanging of large plates,
which is difficult, and because of the number of heats necessary and the
continual working of the material, may lead to the weakening of such plates.
Page 96
McAlpin Hotel, New York City, Operating 2360 Horse Power of
Babcock & Wilcox Boilers
In vertical or semi-vertical water-tube boilers utilizing flat-stayed surfaces
under pressure, these surfaces are ordinarily so located as to offer a
convenient lodging place for flue dust, which fuses into a hard mass, is
difficult of removal and under which corrosion may be going on with no
possibility of detection.
Where stayed surfaces or water legs are features in the design of a water-
tube boiler, the factor of safety of such parts must be most carefully
Babcock & Wilcox Boilers
In vertical or semi-vertical water-tube boilers utilizing flat-stayed surfaces
under pressure, these surfaces are ordinarily so located as to offer a
convenient lodging place for flue dust, which fuses into a hard mass, is
difficult of removal and under which corrosion may be going on with no
possibility of detection.
Where stayed surfaces or water legs are features in the design of a water-
tube boiler, the factor of safety of such parts must be most carefully
Page 97
considered. In such parts too, is the determination of the factor most
difficult, and because of the “rule-of-thumb” determination frequently
necessary, the factor of safety becomes in reality a factor of ignorance. As
opposed to such indeterminate factors of safety, in the Babcock & Wilcox
boiler, when the factor of safety for the drum or drums has been determined,
and such a factor may be determined accurately, the factors for all other
portions of the pressure parts are greatly in excess of that of the drum. All
Babcock & Wilcox boilers are built with a factor of safety of at least five,
and inasmuch as the factor of the safety of the tubes and headers is greatly in
excess of this figure, it applies specifically to the drum or drums. This factor
represents a greater degree of safety than a considerably higher factor
applied to a boiler in which the shell or any riveted portion is acted upon
directly by the fire, or the same factor applied to a boiler utilizing flat-stayed
surface construction, where the accurate determination of the limiting factor
of safety is difficult, if not impossible.
That the factor of safety of stayed surfaces is questionable may perhaps be
best realized from a consideration of the severe requirements as to such
factor called for by the rules and regulations of the Board of Supervising
Inspectors, U. S. Government.
In view of the above, the absence of any stayed surfaces in the Babcock &
Wilcox boiler is obviously a distinguishing advantage where safety is a
factor. It is of interest to note, in the article on the evolution of the Babcock
& Wilcox boiler, that staybolt construction was used in several designs,
found unsatisfactory and unsafe, and discarded.
Another feature in the design of the Babcock & Wilcox boiler tending
toward added safety is its manner of suspension. This has been indicated in
the previous chapter and is of such nature that all of the pressure parts are
free to expand or contract under variations of temperature without in any
way interfering with any part of the boiler setting. The sectional nature of the
boiler allows a flexibility under varying temperature changes that practically
obviates internal strain.
In boilers utilizing water-leg construction, on the other hand, the
construction is rigid, giving rise to serious internal strains and the method of
support ordinarily made necessary by the boiler design is not only
difficult, and because of the “rule-of-thumb” determination frequently
necessary, the factor of safety becomes in reality a factor of ignorance. As
opposed to such indeterminate factors of safety, in the Babcock & Wilcox
boiler, when the factor of safety for the drum or drums has been determined,
and such a factor may be determined accurately, the factors for all other
portions of the pressure parts are greatly in excess of that of the drum. All
Babcock & Wilcox boilers are built with a factor of safety of at least five,
and inasmuch as the factor of the safety of the tubes and headers is greatly in
excess of this figure, it applies specifically to the drum or drums. This factor
represents a greater degree of safety than a considerably higher factor
applied to a boiler in which the shell or any riveted portion is acted upon
directly by the fire, or the same factor applied to a boiler utilizing flat-stayed
surface construction, where the accurate determination of the limiting factor
of safety is difficult, if not impossible.
That the factor of safety of stayed surfaces is questionable may perhaps be
best realized from a consideration of the severe requirements as to such
factor called for by the rules and regulations of the Board of Supervising
Inspectors, U. S. Government.
In view of the above, the absence of any stayed surfaces in the Babcock &
Wilcox boiler is obviously a distinguishing advantage where safety is a
factor. It is of interest to note, in the article on the evolution of the Babcock
& Wilcox boiler, that staybolt construction was used in several designs,
found unsatisfactory and unsafe, and discarded.
Another feature in the design of the Babcock & Wilcox boiler tending
toward added safety is its manner of suspension. This has been indicated in
the previous chapter and is of such nature that all of the pressure parts are
free to expand or contract under variations of temperature without in any
way interfering with any part of the boiler setting. The sectional nature of the
boiler allows a flexibility under varying temperature changes that practically
obviates internal strain.
In boilers utilizing water-leg construction, on the other hand, the
construction is rigid, giving rise to serious internal strains and the method of
support ordinarily made necessary by the boiler design is not only
Page 98
unmechanical but frequently dangerous, due to the fact that proper provision
is not made for expansion and contraction under temperature variations.
[Pg 70]
Boilers utilizing water-leg construction are not ordinarily provided with mud
drums. This is a serious defect in that it allows impurities and sediment to
collect in a portion of the boiler not easily inspected, and corrosion may
result.
Economy—That the water-tube boiler as a class lends itself more readily
than does the fire-tube boiler to a variation in the relation of grate surface,
heating surface and combustion space has been already pointed out. In
economy again, the construction made possible by the use of headers in
Babcock & Wilcox boilers appears as a distinct advantage. Because of this
construction, there is a flexibility possible, in an unlimited variety of heights
and widths that will satisfactorily meet the special requirements of the fuel to
be burned in individual cases.
An extended experience in the design of furnaces best suited for a wide
variety of fuels has made The Babcock & Wilcox Co. leaders in the field of
economy. Furnaces have been built and are in successful operation for
burning anthracite and bituminous coals, lignite, crude oil, gas-house tar,
wood, sawdust and shavings, bagasse, tan bark, natural gas, blast furnace
gas, by-product coke oven gas and for the utilization of waste heat from
commercial processes. The great number of Babcock & Wilcox boilers now
in satisfactory operation under such a wide range of fuel conditions
constitutes an unimpeachable testimonial to the ability to meet all of the
many conditions of service.
The limitations in the draft area of fire-tube boilers as affecting economy
have been pointed out. That a greater draft area is possible in water-tube
boilers does not of necessity indicate that proper advantage of this fact is
taken in all boilers of the water-tube class. In the Babcock & Wilcox boiler,
the large draft area taken in connection with the effective baffling allows the
gases to be brought into intimate contact with all portions of the heating
surfaces and renders such surfaces highly efficient.
is not made for expansion and contraction under temperature variations.
[Pg 70]
Boilers utilizing water-leg construction are not ordinarily provided with mud
drums. This is a serious defect in that it allows impurities and sediment to
collect in a portion of the boiler not easily inspected, and corrosion may
result.
Economy—That the water-tube boiler as a class lends itself more readily
than does the fire-tube boiler to a variation in the relation of grate surface,
heating surface and combustion space has been already pointed out. In
economy again, the construction made possible by the use of headers in
Babcock & Wilcox boilers appears as a distinct advantage. Because of this
construction, there is a flexibility possible, in an unlimited variety of heights
and widths that will satisfactorily meet the special requirements of the fuel to
be burned in individual cases.
An extended experience in the design of furnaces best suited for a wide
variety of fuels has made The Babcock & Wilcox Co. leaders in the field of
economy. Furnaces have been built and are in successful operation for
burning anthracite and bituminous coals, lignite, crude oil, gas-house tar,
wood, sawdust and shavings, bagasse, tan bark, natural gas, blast furnace
gas, by-product coke oven gas and for the utilization of waste heat from
commercial processes. The great number of Babcock & Wilcox boilers now
in satisfactory operation under such a wide range of fuel conditions
constitutes an unimpeachable testimonial to the ability to meet all of the
many conditions of service.
The limitations in the draft area of fire-tube boilers as affecting economy
have been pointed out. That a greater draft area is possible in water-tube
boilers does not of necessity indicate that proper advantage of this fact is
taken in all boilers of the water-tube class. In the Babcock & Wilcox boiler,
the large draft area taken in connection with the effective baffling allows the
gases to be brought into intimate contact with all portions of the heating
surfaces and renders such surfaces highly efficient.
Page 99
In certain designs of water-tube boilers the baffling is such as to render
ineffective certain portions of the heating surface, due to the tendency of
soot and dirt to collect on or behind baffles, in this way causing the
interposition of a layer of non-conducting material between the hot gases
and the heating surfaces.
In Babcock & Wilcox boilers the standard baffle arrangement is such as to
allow the installation of a superheater without in any way altering the path of
the gases from furnace to stack, or requiring a change in the boiler design. In
certain water-tube boilers the baffle arrangement is such that if a superheater
is to be installed a complete change in the ordinary baffle design is
necessary. Frequently to insure sufficiently hot gas striking the heating
surfaces, a portion is by-passed directly from the furnace to the superheater
chamber without passing over any of the boiler heating surfaces. Any such
arrangement will lead to a decrease in economy and the use of boilers
requiring it should be avoided.
Capacity—Babcock & Wilcox boilers are run successfully in every-day
practice at higher ratings than any other boilers in practical service. The
capacities thus obtainable are due directly to the efficient circulation already
pointed out. Inasmuch as the construction utilizing headers has a direct
bearing in producing such circulation, it is also connected with the high
capacities obtainable with this apparatus.
Where intelligently handled and kept properly cleaned, Babcock & Wilcox
boilers are operated in many plants at from 200 to 225 per cent of their rated
evaporative capacity and it is not unusual for them to be operated at 300 per
cent of such rated capacity during periods of peak load.
[Pg 71]
Dry Steam—In the list of the requirements of the perfect steam boiler, the
necessity that dry steam be generated has been pointed out. The Babcock &
Wilcox boiler will deliver dry steam under higher capacities and poorer
conditions of feed water than any other boiler now manufactured. Certain
boilers will, when operated at ordinary ratings, handle poor feed water and
deliver steam in which the moisture content is not objectionable. When these
same boilers are driven at high overloads, there will be a direct tendency to
ineffective certain portions of the heating surface, due to the tendency of
soot and dirt to collect on or behind baffles, in this way causing the
interposition of a layer of non-conducting material between the hot gases
and the heating surfaces.
In Babcock & Wilcox boilers the standard baffle arrangement is such as to
allow the installation of a superheater without in any way altering the path of
the gases from furnace to stack, or requiring a change in the boiler design. In
certain water-tube boilers the baffle arrangement is such that if a superheater
is to be installed a complete change in the ordinary baffle design is
necessary. Frequently to insure sufficiently hot gas striking the heating
surfaces, a portion is by-passed directly from the furnace to the superheater
chamber without passing over any of the boiler heating surfaces. Any such
arrangement will lead to a decrease in economy and the use of boilers
requiring it should be avoided.
Capacity—Babcock & Wilcox boilers are run successfully in every-day
practice at higher ratings than any other boilers in practical service. The
capacities thus obtainable are due directly to the efficient circulation already
pointed out. Inasmuch as the construction utilizing headers has a direct
bearing in producing such circulation, it is also connected with the high
capacities obtainable with this apparatus.
Where intelligently handled and kept properly cleaned, Babcock & Wilcox
boilers are operated in many plants at from 200 to 225 per cent of their rated
evaporative capacity and it is not unusual for them to be operated at 300 per
cent of such rated capacity during periods of peak load.
[Pg 71]
Dry Steam—In the list of the requirements of the perfect steam boiler, the
necessity that dry steam be generated has been pointed out. The Babcock &
Wilcox boiler will deliver dry steam under higher capacities and poorer
conditions of feed water than any other boiler now manufactured. Certain
boilers will, when operated at ordinary ratings, handle poor feed water and
deliver steam in which the moisture content is not objectionable. When these
same boilers are driven at high overloads, there will be a direct tendency to
Page 100
prime and the percentage of moisture in the steam delivered will be high.
This tendency is the result of the lack of proper circulation and once more
there is seen the advantage of the headers of the Babcock & Wilcox boiler,
resulting as it does in the securing of a positive circulation.
In the design of the Babcock & Wilcox boiler sufficient space is provided
between the steam outlet and the disengaging point to insure the steam
passing from the boiler in a dry state without entraining or again picking up
any particles of water in its passage even at high rates of evaporation. Ample
time is given for a complete separation of steam from the water at the
disengaging surface before the steam is carried from the boiler. These two
features, which are additional causes for the ability of the Babcock & Wilcox
boiler to deliver dry steam, result from the proper proportioning of the steam
and water space of the boiler. From the history of the development of the
boiler, it is evident that the cubical capacity per horse power of the steam
and water space has been adopted after numerous experiments.
That the “dry pipe” serves in no way the generally understood function of
such device has been pointed out. As stated, the function of the “dry pipe” in
a Babcock & Wilcox boiler is simply that of a collecting pipe and this
statement holds true regardless of the rate of operation of the boiler.
In certain boilers, “superheating surface” is provided to “dry the steam,” or
to remove the moisture due to priming or foaming. Such surface is
invariably a source of trouble unless the steam is initially dry and a boiler
which will deliver dry steam is obviously to be preferred to one in which
surface must be supplied especially for such purpose. Where superheaters
are installed with Babcock & Wilcox boilers, they are in every sense of the
word superheaters and not driers, the steam being delivered to them in a dry
state.
The question has been raised in connection with the cross drum design of the
Babcock & Wilcox boiler as to its ability to deliver dry steam. Experience
has shown the absolute lack of basis for any such objection. The Babcock &
Wilcox Company at its Bayonne Works some time ago made a series of
experiments to see in what manner the steam generated was separated from
the water either in the drum or in its passage to the drum. Glass peepholes
were installed in each end of a drum in a boiler of the marine design, at the
This tendency is the result of the lack of proper circulation and once more
there is seen the advantage of the headers of the Babcock & Wilcox boiler,
resulting as it does in the securing of a positive circulation.
In the design of the Babcock & Wilcox boiler sufficient space is provided
between the steam outlet and the disengaging point to insure the steam
passing from the boiler in a dry state without entraining or again picking up
any particles of water in its passage even at high rates of evaporation. Ample
time is given for a complete separation of steam from the water at the
disengaging surface before the steam is carried from the boiler. These two
features, which are additional causes for the ability of the Babcock & Wilcox
boiler to deliver dry steam, result from the proper proportioning of the steam
and water space of the boiler. From the history of the development of the
boiler, it is evident that the cubical capacity per horse power of the steam
and water space has been adopted after numerous experiments.
That the “dry pipe” serves in no way the generally understood function of
such device has been pointed out. As stated, the function of the “dry pipe” in
a Babcock & Wilcox boiler is simply that of a collecting pipe and this
statement holds true regardless of the rate of operation of the boiler.
In certain boilers, “superheating surface” is provided to “dry the steam,” or
to remove the moisture due to priming or foaming. Such surface is
invariably a source of trouble unless the steam is initially dry and a boiler
which will deliver dry steam is obviously to be preferred to one in which
surface must be supplied especially for such purpose. Where superheaters
are installed with Babcock & Wilcox boilers, they are in every sense of the
word superheaters and not driers, the steam being delivered to them in a dry
state.
The question has been raised in connection with the cross drum design of the
Babcock & Wilcox boiler as to its ability to deliver dry steam. Experience
has shown the absolute lack of basis for any such objection. The Babcock &
Wilcox Company at its Bayonne Works some time ago made a series of
experiments to see in what manner the steam generated was separated from
the water either in the drum or in its passage to the drum. Glass peepholes
were installed in each end of a drum in a boiler of the marine design, at the
Page 101
point midway between that at which the horizontal circulating tubes entered
the drum and the drum baffle plate. By holding a light at one of these
peepholes the action in the drum was clearly seen through the other. It was
found that with the boiler operated under three-quarter inch ashpit pressure,
which, with the fuel used would be equivalent to approximately 185 per cent
of rating for stationary boiler practice, that each tube was delivering with
great velocity a stream of solid water, which filled the tube for half its cross
sectional area. There was no spray or mist accompanying such delivery,
clearly indicating that the steam had entirely separated from the water in its
passage through the horizontal circulating tubes, which in the boiler in
question were but 50 inches long. [Pg 72]
Northwest Station of the Commonwealth Edison Co., Chicago, Ill. This
Installation Consists of 11,360 Horse Power of Babcock & Wilcox
Boilers and Superheaters, Equipped with Babcock & Wilcox Chain
Grate Stokers
[Pg 73] These experiments proved conclusively that the size of the steam
drums in the cross drum design has no appreciable effect in determining the
amount of liberating surface, and that sufficient liberating surface is
the drum and the drum baffle plate. By holding a light at one of these
peepholes the action in the drum was clearly seen through the other. It was
found that with the boiler operated under three-quarter inch ashpit pressure,
which, with the fuel used would be equivalent to approximately 185 per cent
of rating for stationary boiler practice, that each tube was delivering with
great velocity a stream of solid water, which filled the tube for half its cross
sectional area. There was no spray or mist accompanying such delivery,
clearly indicating that the steam had entirely separated from the water in its
passage through the horizontal circulating tubes, which in the boiler in
question were but 50 inches long. [Pg 72]
Northwest Station of the Commonwealth Edison Co., Chicago, Ill. This
Installation Consists of 11,360 Horse Power of Babcock & Wilcox
Boilers and Superheaters, Equipped with Babcock & Wilcox Chain
Grate Stokers
[Pg 73] These experiments proved conclusively that the size of the steam
drums in the cross drum design has no appreciable effect in determining the
amount of liberating surface, and that sufficient liberating surface is
Page 102
provided in the circulating tubes alone. If further proof of the ability of this
design of boiler to deliver dry steam is required, such proof is perhaps best
seen in the continued use of the Babcock & Wilcox marine boiler, in which
the cross drum is used exclusively, and with which rates of evaporation are
obtained far in excess of those secured in ordinary practice.
Quick Steaming—The advantages of water-tube boilers as a class over fire-
tube boilers in ability to raise steam quickly have been indicated.
Due to the constant and thorough circulation resulting from the sectional
nature of the Babcock & Wilcox boiler, steam may be raised more rapidly
than in practically any other water-tube design.
In starting up a cold Babcock & Wilcox boiler with either coal or oil fuel,
where a proper furnace arrangement is supplied, steam may be raised to a
pressure of 200 pounds in less than half an hour. With a Babcock & Wilcox
boiler in a test where forced draft was available, steam was raised from an
initial temperature of the boiler and its contained water of 72 degrees to a
pressure of 200 pounds, in 12½ minutes after lighting the fire. The boiler
also responds quickly in starting from banked fires, especially where forced
draft is available.
In Babcock & Wilcox boilers the water is divided into many small streams
which circulate without undue frictional resistance in thin envelopes passing
through the hottest part of the furnace, the steam being carried rapidly to the
disengaging surface. There is no part of the boiler exposed to the heat of the
fire that is not in contact with water internally, and as a result there is no
danger of overheating on starting up quickly nor can leaks occur from
unequal expansion such as might be the case where an attempt is made to
raise steam rapidly in boilers using water leg construction.
Storage Capacity for Steam and Water—Where sufficient steam and water
capacity are not provided in a boiler, its action will be irregular, the steam
pressure varying over wide limits and the water level being subject to
frequent and rapid fluctuation.
Owing to the small relative weight of steam, water capacity is of greater
importance in this respect than steam space. With a gauge pressure of 180
design of boiler to deliver dry steam is required, such proof is perhaps best
seen in the continued use of the Babcock & Wilcox marine boiler, in which
the cross drum is used exclusively, and with which rates of evaporation are
obtained far in excess of those secured in ordinary practice.
Quick Steaming—The advantages of water-tube boilers as a class over fire-
tube boilers in ability to raise steam quickly have been indicated.
Due to the constant and thorough circulation resulting from the sectional
nature of the Babcock & Wilcox boiler, steam may be raised more rapidly
than in practically any other water-tube design.
In starting up a cold Babcock & Wilcox boiler with either coal or oil fuel,
where a proper furnace arrangement is supplied, steam may be raised to a
pressure of 200 pounds in less than half an hour. With a Babcock & Wilcox
boiler in a test where forced draft was available, steam was raised from an
initial temperature of the boiler and its contained water of 72 degrees to a
pressure of 200 pounds, in 12½ minutes after lighting the fire. The boiler
also responds quickly in starting from banked fires, especially where forced
draft is available.
In Babcock & Wilcox boilers the water is divided into many small streams
which circulate without undue frictional resistance in thin envelopes passing
through the hottest part of the furnace, the steam being carried rapidly to the
disengaging surface. There is no part of the boiler exposed to the heat of the
fire that is not in contact with water internally, and as a result there is no
danger of overheating on starting up quickly nor can leaks occur from
unequal expansion such as might be the case where an attempt is made to
raise steam rapidly in boilers using water leg construction.
Storage Capacity for Steam and Water—Where sufficient steam and water
capacity are not provided in a boiler, its action will be irregular, the steam
pressure varying over wide limits and the water level being subject to
frequent and rapid fluctuation.
Owing to the small relative weight of steam, water capacity is of greater
importance in this respect than steam space. With a gauge pressure of 180
Page 103
pounds per square inch, 8 cubic feet of steam, which is equivalent to one-
half cubic foot of water space, are required to supply one boiler horse power
for one minute and if no heat be supplied to the boiler during such an
interval, the pressure will drop to 150 pounds per square inch. The volume
of steam space, therefore, may be over rated, but if this be too small, the
steam passing off will carry water with it in the form of spray. Too great a
water space results in slow steaming and waste of fuel in starting up; while
too much steam space adds to the radiating surface and increases the losses
from that cause.
That the steam and water space of the Babcock & Wilcox boiler are the
result of numerous experiments has previously been pointed out.
Accessibility—Cleaning. That water-tube boilers are more accessible as a
class than are fire-tube boilers has been indicated. All water-tube boilers,
however, are not equally accessible. In certain designs, due to the
arrangement of baffling used it is practically impossible to remove all
deposits of soot and dirt. Frequently, in order to cheapen the product,
sufficient cleaning and access doors are not supplied as part [Pg 74]
[Pg 75] of the boiler equipment. The tendency of soot to collect on the crown
sheets of certain vertical water-tube boilers has been noted. Such deposits
are difficult to remove and if corrosion goes on beneath such a covering the
sheet may crack and an explosion result.
half cubic foot of water space, are required to supply one boiler horse power
for one minute and if no heat be supplied to the boiler during such an
interval, the pressure will drop to 150 pounds per square inch. The volume
of steam space, therefore, may be over rated, but if this be too small, the
steam passing off will carry water with it in the form of spray. Too great a
water space results in slow steaming and waste of fuel in starting up; while
too much steam space adds to the radiating surface and increases the losses
from that cause.
That the steam and water space of the Babcock & Wilcox boiler are the
result of numerous experiments has previously been pointed out.
Accessibility—Cleaning. That water-tube boilers are more accessible as a
class than are fire-tube boilers has been indicated. All water-tube boilers,
however, are not equally accessible. In certain designs, due to the
arrangement of baffling used it is practically impossible to remove all
deposits of soot and dirt. Frequently, in order to cheapen the product,
sufficient cleaning and access doors are not supplied as part [Pg 74]
[Pg 75] of the boiler equipment. The tendency of soot to collect on the crown
sheets of certain vertical water-tube boilers has been noted. Such deposits
are difficult to remove and if corrosion goes on beneath such a covering the
sheet may crack and an explosion result.
Page 104
Rear View—Longitudinal Drum Vertical Header Boiler, Showing Access
Doors to Rear Headers
It is almost impossible to thoroughly clean water legs internally, and in such
places also is there a tendency to unsuspected corrosion under deposits that
cannot be removed.
In Babcock & Wilcox boilers every portion of the interior of the heating
surfaces can be reached and kept clean, while any soot deposited on the
exterior surfaces can be blown off while the boiler is under pressure.
Inspection—The accessibility which makes possible the thorough cleaning
of all portions of the Babcock & Wilcox boiler also provides a means for a
Doors to Rear Headers
It is almost impossible to thoroughly clean water legs internally, and in such
places also is there a tendency to unsuspected corrosion under deposits that
cannot be removed.
In Babcock & Wilcox boilers every portion of the interior of the heating
surfaces can be reached and kept clean, while any soot deposited on the
exterior surfaces can be blown off while the boiler is under pressure.
Inspection—The accessibility which makes possible the thorough cleaning
of all portions of the Babcock & Wilcox boiler also provides a means for a
Page 105
thorough inspection.
Drums are accessible for internal inspection by the removal of the manhole
plates. Front headers may be inspected through large doors furnished for the
purpose. Rear headers in the inclined header designs may be inspected from
the chamber formed by such headers and the rear wall of the boiler. In the
vertical header designs rear tube doors are furnished, as has been stated. In
certain designs of water-tube boilers in order to assure accessibility for
inspection of the rear ends of the tubes, the rear portion of the boiler is
exposed to the atmosphere with resulting excessive radiation losses. In other
designs the means of access to the rear ends of the tubes are of a makeshift
and unworkmanlike character.
By the removal of handhole plates, all tubes in a Babcock & Wilcox boiler
may be inspected for their full length either for the presence of scale or for
suspected corrosion.
Repairs—In Babcock & Wilcox boilers the possession of great strength, the
elimination of stresses due to uneven temperatures and of the resulting
danger of leaks and corrosion, the protection of the drums from the intense
heat of the fire, and the decreased liability of the scale forming matter to
lodge on the hottest tube surfaces, all tend to minimize the necessity for
repairs. The tubes of the Babcock & Wilcox boiler are practically the only
part which may need renewal and these only at infrequent intervals When
necessary, such renewals may be made cheaply and quickly. A small stock of
tubes, 4 inches in diameter, of sufficient length for the boiler used, is all that
need be carried to make renewals.
Repairs in water-leg boilers are difficult at best and frequently unsatisfactory
when completed. When staybolt replacements are necessary, in order to get
at the inner sheet of the water leg, several tubes must in some cases be cut
out. Not infrequently a replacement of an entire water leg is necessary and
this is difficult and requires a lengthy shutdown. With the Babcock &
Wilcox boiler, on the other hand, even if it is necessary to replace a section,
this may be done in a few hours after the boiler is cool.
In the case of certain staybolt failures the working pressure of a repaired
boiler utilizing such construction will frequently be lowered by the insurance
Drums are accessible for internal inspection by the removal of the manhole
plates. Front headers may be inspected through large doors furnished for the
purpose. Rear headers in the inclined header designs may be inspected from
the chamber formed by such headers and the rear wall of the boiler. In the
vertical header designs rear tube doors are furnished, as has been stated. In
certain designs of water-tube boilers in order to assure accessibility for
inspection of the rear ends of the tubes, the rear portion of the boiler is
exposed to the atmosphere with resulting excessive radiation losses. In other
designs the means of access to the rear ends of the tubes are of a makeshift
and unworkmanlike character.
By the removal of handhole plates, all tubes in a Babcock & Wilcox boiler
may be inspected for their full length either for the presence of scale or for
suspected corrosion.
Repairs—In Babcock & Wilcox boilers the possession of great strength, the
elimination of stresses due to uneven temperatures and of the resulting
danger of leaks and corrosion, the protection of the drums from the intense
heat of the fire, and the decreased liability of the scale forming matter to
lodge on the hottest tube surfaces, all tend to minimize the necessity for
repairs. The tubes of the Babcock & Wilcox boiler are practically the only
part which may need renewal and these only at infrequent intervals When
necessary, such renewals may be made cheaply and quickly. A small stock of
tubes, 4 inches in diameter, of sufficient length for the boiler used, is all that
need be carried to make renewals.
Repairs in water-leg boilers are difficult at best and frequently unsatisfactory
when completed. When staybolt replacements are necessary, in order to get
at the inner sheet of the water leg, several tubes must in some cases be cut
out. Not infrequently a replacement of an entire water leg is necessary and
this is difficult and requires a lengthy shutdown. With the Babcock &
Wilcox boiler, on the other hand, even if it is necessary to replace a section,
this may be done in a few hours after the boiler is cool.
In the case of certain staybolt failures the working pressure of a repaired
boiler utilizing such construction will frequently be lowered by the insurance
Page 106
companies when the boiler is again placed in service. The sectional nature of
the Babcock & Wilcox boiler enables it to maintain its original working
pressure over long periods of time, almost regardless of the nature of any
repair that may be required.
Durability—Babcock & Wilcox boilers are being operated in every-day
service with entirely satisfactory results and under the same steam pressure
as that for which [Pg 76]
[Pg 77] they were originally sold that have been operated from thirty to thirty-
five years. It is interesting to note in considering the life of a boiler that the
length of life of a Babcock & Wilcox boiler must be taken as the criterion of
what length of life is possible. This is due to the fact that there are Babcock
& Wilcox boilers in operation to-day that have been in service from a time
that antedates by a considerable margin that at which the manufacturer of
any other water-tube boiler now on the market was started.
1456 Horse-power Installation of Babcock & Wilcox Boilers at the
Raritan Woolen Mills, Raritan, N. J. The First of These Boilers were
Installed in 1878 and 1881 and are still Operated at 80 Pounds Pressure
the Babcock & Wilcox boiler enables it to maintain its original working
pressure over long periods of time, almost regardless of the nature of any
repair that may be required.
Durability—Babcock & Wilcox boilers are being operated in every-day
service with entirely satisfactory results and under the same steam pressure
as that for which [Pg 76]
[Pg 77] they were originally sold that have been operated from thirty to thirty-
five years. It is interesting to note in considering the life of a boiler that the
length of life of a Babcock & Wilcox boiler must be taken as the criterion of
what length of life is possible. This is due to the fact that there are Babcock
& Wilcox boilers in operation to-day that have been in service from a time
that antedates by a considerable margin that at which the manufacturer of
any other water-tube boiler now on the market was started.
1456 Horse-power Installation of Babcock & Wilcox Boilers at the
Raritan Woolen Mills, Raritan, N. J. The First of These Boilers were
Installed in 1878 and 1881 and are still Operated at 80 Pounds Pressure
Page 107
Probably the very best evidence of the value of the Babcock & Wilcox boiler
as a steam generator and of the reliability of the apparatus, is seen in the
sales of the company. Since the company was formed, there have been sold
throughout the world over 9,900,000 horse power.
A feature that cannot be overlooked in the consideration of the advantages of
the Babcock & Wilcox boiler is the fact that as a part of the organization
back of the boiler, there is a body of engineers of recognized ability, ready at
all times to assist its customers in every possible way.
[Pg 78]
2400 Horse-power Installation of Babcock & Wilcox Boilers in the
Union Station Power House of the Pennsylvania Railroad Co.,
Pittsburgh, Pa. This Company has a Total of 28,500 Horse Power of
Babcock & Wilcox Boilers Installed
as a steam generator and of the reliability of the apparatus, is seen in the
sales of the company. Since the company was formed, there have been sold
throughout the world over 9,900,000 horse power.
A feature that cannot be overlooked in the consideration of the advantages of
the Babcock & Wilcox boiler is the fact that as a part of the organization
back of the boiler, there is a body of engineers of recognized ability, ready at
all times to assist its customers in every possible way.
[Pg 78]
2400 Horse-power Installation of Babcock & Wilcox Boilers in the
Union Station Power House of the Pennsylvania Railroad Co.,
Pittsburgh, Pa. This Company has a Total of 28,500 Horse Power of
Babcock & Wilcox Boilers Installed
Page 108
[Pg 79]
Page 109
HEAT AND ITS MEASUREMENT
The usual conception of heat is that it is a form of energy produced by the vibratory motion of
the minute particles or molecules of a body. All bodies are assumed to be composed of these
molecules, which are held together by mutual cohesion and yet are in a state of continual
vibration. The hotter a body or the more heat added to it, the more vigorous will be the
vibrations of the molecules.
As is well known, the effect of heat on a body may be to change its temperature, its volume, or
its state, that is, from solid to liquid or from liquid to gaseous. Where water is melted from ice
and evaporated into steam, the various changes are admirably described in the lecture by Mr.
Babcock on “The Theory of Steam Making”, given in the next chapter.
The change in temperature of a body is
ordinarily measured by thermometers, though
for very high temperatures so-called
pyrometers are used. The latter are dealt with
under the heading “High Temperature
Measurements” at the end of this chapter.
By reason of the uniform expansion of
mercury and its great sensitiveness to heat, it
is the fluid most commonly used in the
construction of thermometers. In all
thermometers the freezing point and the
boiling point of water, under mean or average
atmospheric pressure at sea level, are assumed
as two fixed points, but the division of the
scale between these two points varies in
different countries. The freezing point is
determined by the use of melting ice and for
this reason is often called the melting point.
There are in use three thermometer scales
known as the Fahrenheit, the Centigrade or
Celsius, and the Réaumur. As shown in Fig.
11, in the Fahrenheit scale, the space between
the two fixed points is divided into 180 parts;
Fig. 11
the boiling point is marked 212, and the
freezing point is marked 32, and zero is a
temperature which, at the time this
thermometer was invented, was incorrectly imagined to be the lowest temperature attainable. In
the centigrade and the Réaumur scales, the distance between the two fixed points is divided into
100 and 80 parts, respectively. In each of these two scales the freezing point is marked zero, and
The usual conception of heat is that it is a form of energy produced by the vibratory motion of
the minute particles or molecules of a body. All bodies are assumed to be composed of these
molecules, which are held together by mutual cohesion and yet are in a state of continual
vibration. The hotter a body or the more heat added to it, the more vigorous will be the
vibrations of the molecules.
As is well known, the effect of heat on a body may be to change its temperature, its volume, or
its state, that is, from solid to liquid or from liquid to gaseous. Where water is melted from ice
and evaporated into steam, the various changes are admirably described in the lecture by Mr.
Babcock on “The Theory of Steam Making”, given in the next chapter.
The change in temperature of a body is
ordinarily measured by thermometers, though
for very high temperatures so-called
pyrometers are used. The latter are dealt with
under the heading “High Temperature
Measurements” at the end of this chapter.
By reason of the uniform expansion of
mercury and its great sensitiveness to heat, it
is the fluid most commonly used in the
construction of thermometers. In all
thermometers the freezing point and the
boiling point of water, under mean or average
atmospheric pressure at sea level, are assumed
as two fixed points, but the division of the
scale between these two points varies in
different countries. The freezing point is
determined by the use of melting ice and for
this reason is often called the melting point.
There are in use three thermometer scales
known as the Fahrenheit, the Centigrade or
Celsius, and the Réaumur. As shown in Fig.
11, in the Fahrenheit scale, the space between
the two fixed points is divided into 180 parts;
Fig. 11
the boiling point is marked 212, and the
freezing point is marked 32, and zero is a
temperature which, at the time this
thermometer was invented, was incorrectly imagined to be the lowest temperature attainable. In
the centigrade and the Réaumur scales, the distance between the two fixed points is divided into
100 and 80 parts, respectively. In each of these two scales the freezing point is marked zero, and
Page 110
the boiling point is marked 100 in the centigrade and 80 in the Réaumur. Each of the 180, 100
or 80 divisions in the respective thermometers is called a degree.
Table 3 and appended formulae are useful for converting from one scale to another.
In the United States the bulbs of high-grade thermometers are usually made of either Jena 58 III
borosilicate thermometer glass or Jena 16 III glass, the stems being made of ordinary glass. The
Jena 16 III glass is not suitable for use at temperatures much above 850 degrees Fahrenheit and
the harder Jena 59 III should be used in thermometers for temperatures higher than this.
Below the boiling point, the hydrogen-gas thermometer is the almost universal standard with
which mercurial thermometers may be compared, while above this point [Pg 80] the nitrogen-gas
thermometer is used. In both of these standards the change in temperature is measured by the
change in pressure of a constant volume of the gas.
In graduating a mercurial thermometer for the Fahrenheit scale, ordinarily a degree is
represented as 1 ⁄ 180 part of the volume of the stem between the readings at the melting point of
ice and the boiling point of water. For temperatures above the latter, the scale is extended in
degrees of the same volume. For very accurate work, however, the thermometer may be
graduated to read true-gas-scale temperatures by comparing it with the gas thermometer and
marking the temperatures at 25 or 50 degree intervals. Each degree is then 1 ⁄ 25 or 1 ⁄ 50 of the
volume of the stem in each interval.
Every thermometer, especially if intended for use above the boiling point, should be suitably
annealed before it is used. If this is not done, the true melting point and also the “fundamental
interval”, that is, the interval between the melting and the boiling points, may change
considerably. After continued use at the higher temperatures also, the melting point will change,
so that the thermometer must be calibrated occasionally to insure accurate readings.
TABLE 3
COMPARISON OF THERMOMETER SCALES
Fahrenheit Centigrade Réaumur Fahrenheit Centigrade Réaumur
Absolute Zero -459.64 -273.13 -218.50 50 10.00 8.00
0.00 -17.78 -14.22 75 23.89 19.11
10.00 -12.22 -9.78 100 37.78 30.22
20.00 -6.67 -5.33 200 93.33 74.67
Boiling
30.00 -1.11 -0.89 212 100.00 80.00
Point
Freezing Point 32.00 0.00 0.00 250 121.11 96.89
Maximum 300 148.89 119.11
Density
of Water 39.10 3.94 3.15 350 176.67 141.33
F = 9 ⁄ 5 C+32° = 9 ⁄ 4 R+32° C = 5 ⁄ 9 (F-32°) = 5 ⁄ 4 R R = 4 ⁄ 9 (F-32°) = 4 ⁄ 5 C
or 80 divisions in the respective thermometers is called a degree.
Table 3 and appended formulae are useful for converting from one scale to another.
In the United States the bulbs of high-grade thermometers are usually made of either Jena 58 III
borosilicate thermometer glass or Jena 16 III glass, the stems being made of ordinary glass. The
Jena 16 III glass is not suitable for use at temperatures much above 850 degrees Fahrenheit and
the harder Jena 59 III should be used in thermometers for temperatures higher than this.
Below the boiling point, the hydrogen-gas thermometer is the almost universal standard with
which mercurial thermometers may be compared, while above this point [Pg 80] the nitrogen-gas
thermometer is used. In both of these standards the change in temperature is measured by the
change in pressure of a constant volume of the gas.
In graduating a mercurial thermometer for the Fahrenheit scale, ordinarily a degree is
represented as 1 ⁄ 180 part of the volume of the stem between the readings at the melting point of
ice and the boiling point of water. For temperatures above the latter, the scale is extended in
degrees of the same volume. For very accurate work, however, the thermometer may be
graduated to read true-gas-scale temperatures by comparing it with the gas thermometer and
marking the temperatures at 25 or 50 degree intervals. Each degree is then 1 ⁄ 25 or 1 ⁄ 50 of the
volume of the stem in each interval.
Every thermometer, especially if intended for use above the boiling point, should be suitably
annealed before it is used. If this is not done, the true melting point and also the “fundamental
interval”, that is, the interval between the melting and the boiling points, may change
considerably. After continued use at the higher temperatures also, the melting point will change,
so that the thermometer must be calibrated occasionally to insure accurate readings.
TABLE 3
COMPARISON OF THERMOMETER SCALES
Fahrenheit Centigrade Réaumur Fahrenheit Centigrade Réaumur
Absolute Zero -459.64 -273.13 -218.50 50 10.00 8.00
0.00 -17.78 -14.22 75 23.89 19.11
10.00 -12.22 -9.78 100 37.78 30.22
20.00 -6.67 -5.33 200 93.33 74.67
Boiling
30.00 -1.11 -0.89 212 100.00 80.00
Point
Freezing Point 32.00 0.00 0.00 250 121.11 96.89
Maximum 300 148.89 119.11
Density
of Water 39.10 3.94 3.15 350 176.67 141.33
F = 9 ⁄ 5 C+32° = 9 ⁄ 4 R+32° C = 5 ⁄ 9 (F-32°) = 5 ⁄ 4 R R = 4 ⁄ 9 (F-32°) = 4 ⁄ 5 C
Page 111
As a general rule thermometers are graduated to read correctly for total immersion, that is, with
bulb and stem of the thermometer at the same temperature, and they should be used in this way
when compared with a standard thermometer. If the stem emerges into space either hotter or
colder than that in which the bulb is placed, a “stem correction” must be applied to the observed
temperature in addition to any correction that may be found in the comparison with the
standard. For instance, for a particular thermometer, comparison with the standard with both
fully immersed made necessary the following corrections:
Temperature Correction Temperature Correction
40°F 0.0 300°F +2.5
100°F 0.0 400°F -0.5
200°F 0.0 500°F -2.5
When the sign of the correction is positive (+) it must be added to the observed reading, and
when the sign is a negative (-) the correction must be subtracted. The formula for the stem
correction is as follows:
Stem correction = 0.000085 × n (T- t )
[Pg 81] in which T is the observed temperature, t is the mean temperature of the emergent
column, n is the number of degrees of mercury column emergent, and 0.000085 is the
difference between the coefficient of expansion of the mercury and that in the glass in the stem.
Suppose the observed temperature is 400 degrees and the thermometer is immersed to the 200
degrees mark, so that 200 degrees of the mercury column project into the air. The mean
temperature of the emergent column may be found by tying another thermometer on the stem
with the bulb at the middle of the emergent mercury column as in Fig. 12. Suppose this mean
temperature is 85 degrees, then
Stem correction = 0.000085 × 200 × (400 - 85) = 5.3 degrees.
As the stem is at a lower temperature than the bulb, the thermometer will evidently read too
low, so that this correction must be added to the observed reading to find the reading
corresponding to total immersion. The corrected reading will therefore be 405.3 degrees. If this
thermometer is to be corrected in accordance with the calibrated corrections given above, we
note that a further correction of 0.5 must be applied to the observed reading at this temperature,
so that the correct temperature is 405.3 - 0.5 = 404.8 degrees or 405 degrees.
Fig. 12 shows how a stem correction can be obtained for the case just described.
Fig. 13 affords an opportunity for comparing the scale of a thermometer correct for total
immersion with one which will read correctly when submerged to the 300 degrees mark, the
stem being exposed at a mean temperature of 110 degrees Fahrenheit, a temperature often
prevailing when thermometers are used for measuring temperatures in steam mains.
Absolute Zero —Experiments show that at 32 degrees Fahrenheit a perfect gas expands 1 ⁄
491.64 part of its volume if its pressure remains constant and its temperature is increased one
bulb and stem of the thermometer at the same temperature, and they should be used in this way
when compared with a standard thermometer. If the stem emerges into space either hotter or
colder than that in which the bulb is placed, a “stem correction” must be applied to the observed
temperature in addition to any correction that may be found in the comparison with the
standard. For instance, for a particular thermometer, comparison with the standard with both
fully immersed made necessary the following corrections:
Temperature Correction Temperature Correction
40°F 0.0 300°F +2.5
100°F 0.0 400°F -0.5
200°F 0.0 500°F -2.5
When the sign of the correction is positive (+) it must be added to the observed reading, and
when the sign is a negative (-) the correction must be subtracted. The formula for the stem
correction is as follows:
Stem correction = 0.000085 × n (T- t )
[Pg 81] in which T is the observed temperature, t is the mean temperature of the emergent
column, n is the number of degrees of mercury column emergent, and 0.000085 is the
difference between the coefficient of expansion of the mercury and that in the glass in the stem.
Suppose the observed temperature is 400 degrees and the thermometer is immersed to the 200
degrees mark, so that 200 degrees of the mercury column project into the air. The mean
temperature of the emergent column may be found by tying another thermometer on the stem
with the bulb at the middle of the emergent mercury column as in Fig. 12. Suppose this mean
temperature is 85 degrees, then
Stem correction = 0.000085 × 200 × (400 - 85) = 5.3 degrees.
As the stem is at a lower temperature than the bulb, the thermometer will evidently read too
low, so that this correction must be added to the observed reading to find the reading
corresponding to total immersion. The corrected reading will therefore be 405.3 degrees. If this
thermometer is to be corrected in accordance with the calibrated corrections given above, we
note that a further correction of 0.5 must be applied to the observed reading at this temperature,
so that the correct temperature is 405.3 - 0.5 = 404.8 degrees or 405 degrees.
Fig. 12 shows how a stem correction can be obtained for the case just described.
Fig. 13 affords an opportunity for comparing the scale of a thermometer correct for total
immersion with one which will read correctly when submerged to the 300 degrees mark, the
stem being exposed at a mean temperature of 110 degrees Fahrenheit, a temperature often
prevailing when thermometers are used for measuring temperatures in steam mains.
Absolute Zero —Experiments show that at 32 degrees Fahrenheit a perfect gas expands 1 ⁄
491.64 part of its volume if its pressure remains constant and its temperature is increased one
Page 112
degree. Thus if gas at 32 degrees Fahrenheit
occupies 100 cubic feet and its temperature
is increased one degree, its volume will be
increased to 100 + 100 ⁄ 491.64 = 100.203
cubic feet. For a rise of two degrees the
volume would be 100 + (100 × 2) / 491.64 =
100.406 cubic feet. If this rate of expansion
per one degree held good at all temperatures,
and experiment shows that it does above the
freezing point, the gas, if its pressure
remained the same, would double its
volume, if raised to a temperature of 32 +
491.64 = 523.64 degrees Fahrenheit, while
under a diminution of temperature it would
shrink and finally disappear at a temperature
of 491.64 - 32 = 459.64 degrees below zero
Fahrenheit. While undoubtedly some change
in the law would take place before the lower
temperature could be reached, there is no
reason why the law may not be used within
the range of temperature where it is known
to hold good. From this explanation it is
evident that under a constant pressure the
Fig. 12 volume of a gas will vary as the number of Fig. 13
degrees between its temperature and the
temperature of -459.64 degrees Fahrenheit.
To simplify the [Pg 82]
[Pg 83] application of the law, a new thermometric scale is constructed as follows: the point
corresponding to -460 degrees Fahrenheit, is taken as the zero point on the new scale, and the
degrees are identical in magnitude with those on the Fahrenheit scale. Temperatures referred to
this new scale are called absolute temperatures and the point -460 degrees Fahrenheit (= -273
degrees centigrade) is called the absolute zero. To convert any temperature Fahrenheit to
absolute temperature, add 460 degrees to the temperature on the Fahrenheit scale: thus 54
degrees Fahrenheit will be 54 + 460 = 514 degrees absolute temperature; 113 degrees
Fahrenheit will likewise be equal to 113 + 460 = 573 degrees absolute temperature. If one
pound of gas is at a temperature of 54 degrees Fahrenheit and another pound is at a temperature
of 114 degrees Fahrenheit the respective volumes at a given pressure would be in the ratio of
514 to 573.
occupies 100 cubic feet and its temperature
is increased one degree, its volume will be
increased to 100 + 100 ⁄ 491.64 = 100.203
cubic feet. For a rise of two degrees the
volume would be 100 + (100 × 2) / 491.64 =
100.406 cubic feet. If this rate of expansion
per one degree held good at all temperatures,
and experiment shows that it does above the
freezing point, the gas, if its pressure
remained the same, would double its
volume, if raised to a temperature of 32 +
491.64 = 523.64 degrees Fahrenheit, while
under a diminution of temperature it would
shrink and finally disappear at a temperature
of 491.64 - 32 = 459.64 degrees below zero
Fahrenheit. While undoubtedly some change
in the law would take place before the lower
temperature could be reached, there is no
reason why the law may not be used within
the range of temperature where it is known
to hold good. From this explanation it is
evident that under a constant pressure the
Fig. 12 volume of a gas will vary as the number of Fig. 13
degrees between its temperature and the
temperature of -459.64 degrees Fahrenheit.
To simplify the [Pg 82]
[Pg 83] application of the law, a new thermometric scale is constructed as follows: the point
corresponding to -460 degrees Fahrenheit, is taken as the zero point on the new scale, and the
degrees are identical in magnitude with those on the Fahrenheit scale. Temperatures referred to
this new scale are called absolute temperatures and the point -460 degrees Fahrenheit (= -273
degrees centigrade) is called the absolute zero. To convert any temperature Fahrenheit to
absolute temperature, add 460 degrees to the temperature on the Fahrenheit scale: thus 54
degrees Fahrenheit will be 54 + 460 = 514 degrees absolute temperature; 113 degrees
Fahrenheit will likewise be equal to 113 + 460 = 573 degrees absolute temperature. If one
pound of gas is at a temperature of 54 degrees Fahrenheit and another pound is at a temperature
of 114 degrees Fahrenheit the respective volumes at a given pressure would be in the ratio of
514 to 573.
Page 113
Ninety-sixth Street Station of the New York Railways Co., New York City, Operating
20,000 Horse Power of Babcock & Wilcox Boilers. This Company and its Allied
Companies Operate a Total of 100,000 Horse Power of Babcock & Wilcox Boilers
British Thermal Unit —The quantitative measure of heat is the British thermal unit, ordinarily
written B. t. u. This is the quantity of heat required to raise the temperature of one pound of
pure water one degree at 62 degrees Fahrenheit; that is, from 62 degrees to 63 degrees. In the
metric system this unit is the calorie and is the heat necessary to raise the temperature of one
kilogram of pure water from 15 degrees to 16 degrees centigrade. These two definitions lead to
a discrepancy of 0.03 of 1 per cent, which is insignificant for engineering purposes, and in the
following the B. t. u. is taken with this discrepancy ignored. The discrepancy is due to the fact
that there is a slight difference in the specific heat of water at 15 degrees centigrade and 62
degrees Fahrenheit. The two units may be compared thus:
1 Calorie = 3.968 B. t. u. 1 B. t. u. = 0.252 Calories.
Unit Water Temperature Rise
1 B. t. u. 1 Pound 1 Degree Fahrenheit
1 Calorie 1 Kilogram 1 Degree centigrade
But 1 kilogram = 2.2046 pounds and 1 degree centigrade = 9 ⁄ 5 degree Fahrenheit.
Hence 1 calorie = (2.2046 × 9 ⁄ 5 ) = 3.968 B. t. u.
The heat values in B. t. u. are ordinarily given per pound, and the heat values in calories per
kilogram, in which case the B. t. u. per pound are approximately equivalent to 9 ⁄ 5 the calories
20,000 Horse Power of Babcock & Wilcox Boilers. This Company and its Allied
Companies Operate a Total of 100,000 Horse Power of Babcock & Wilcox Boilers
British Thermal Unit —The quantitative measure of heat is the British thermal unit, ordinarily
written B. t. u. This is the quantity of heat required to raise the temperature of one pound of
pure water one degree at 62 degrees Fahrenheit; that is, from 62 degrees to 63 degrees. In the
metric system this unit is the calorie and is the heat necessary to raise the temperature of one
kilogram of pure water from 15 degrees to 16 degrees centigrade. These two definitions lead to
a discrepancy of 0.03 of 1 per cent, which is insignificant for engineering purposes, and in the
following the B. t. u. is taken with this discrepancy ignored. The discrepancy is due to the fact
that there is a slight difference in the specific heat of water at 15 degrees centigrade and 62
degrees Fahrenheit. The two units may be compared thus:
1 Calorie = 3.968 B. t. u. 1 B. t. u. = 0.252 Calories.
Unit Water Temperature Rise
1 B. t. u. 1 Pound 1 Degree Fahrenheit
1 Calorie 1 Kilogram 1 Degree centigrade
But 1 kilogram = 2.2046 pounds and 1 degree centigrade = 9 ⁄ 5 degree Fahrenheit.
Hence 1 calorie = (2.2046 × 9 ⁄ 5 ) = 3.968 B. t. u.
The heat values in B. t. u. are ordinarily given per pound, and the heat values in calories per
kilogram, in which case the B. t. u. per pound are approximately equivalent to 9 ⁄ 5 the calories
Page 114
per kilogram.
As determined by Joule, heat energy has a certain definite relation to work, one British thermal
unit being equivalent from his determinations to 772 foot pounds. Rowland, a later investigator,
found that 778 foot pounds were a more exact equivalent. Still later investigations indicate that
the correct value for a B. t. u. is 777.52 foot pounds or approximately 778. The relation of heat
energy to work as determined is a demonstration of the first law of thermo-dynamics, namely,
that heat and mechanical energy are mutually convertible in the ratio of 778 foot pounds for one
British thermal unit. This law, algebraically expressed, is W = JH; W being the work done in
foot pounds, H being the heat in B. t. u., and J being Joules equivalent. Thus 1000 B. t. u.’s
would be capable of doing 1000 × 778 = 778000 foot pounds of work.
Specific Heat —The specific heat of a substance is the quantity of heat expressed in thermal
units required to raise or lower the temperature of a unit weight of any substance at a given
temperature one degree. This quantity will vary for different substances For example, it requires
about 16 B. t. u. to raise the temperature of one [Pg 84] pound of ice 32 degrees or 0.5 B. t. u. to
raise it one degree, while it requires approximately 180 B. t. u. to raise the temperature of one
pound of water 180 degrees or one B. t. u. for one degree.
If then, a pound of water be considered as a standard, the ratio of the amount of heat required to
raise a similar unit of any other substance one degree, to the amount required to raise a pound
of water one degree is known as the specific heat of that substance. Thus since one pound of
water required one B. t. u. to raise its temperature one degree, and one pound of ice requires
about 0.5 degrees to raise its temperature one degree, the ratio is 0.5 which is the specific heat
of ice. To be exact, the specific heat of ice is 0.504, hence 32 degrees × 0.504 = 16.128 B. t. u.
would be required to raise the temperature of one pound of ice from 0 to 32 degrees. For solids,
at ordinary temperatures, the specific heat may be considered a constant for each individual
substance, although it is variable for high temperatures. In the case of gases a distinction must
be made between specific heat at constant volume, and at constant pressure.
Where specific heat is stated alone, specific heat at ordinary temperature is implied, and mean
specific heat refers to the average value of this quantity between the temperatures named.
The specific heat of a mixture of gases is obtained by multiplying the specific heat of each
constituent gas by the percentage by weight of that gas in the mixture, and dividing the sum of
the products by 100. The specific heat of a gas whose composition by weight is CO 2 , 13 per
cent; CO, 0.4 per cent; O, 8 per cent; N, 78.6 per cent, is found as follows:
CO 2 13.0 × 0.2170 = 2.82100
CO 0.4 × 0.2479 = 0.09916
O 8.0 × 0.2175 = 1.74000
N 78.6 × 0.2438 = 19.16268
–––– –––––––
100.0 = 23.82284
and 23.8228 ÷ 100 = 0.238 = specific heat of the gas.
As determined by Joule, heat energy has a certain definite relation to work, one British thermal
unit being equivalent from his determinations to 772 foot pounds. Rowland, a later investigator,
found that 778 foot pounds were a more exact equivalent. Still later investigations indicate that
the correct value for a B. t. u. is 777.52 foot pounds or approximately 778. The relation of heat
energy to work as determined is a demonstration of the first law of thermo-dynamics, namely,
that heat and mechanical energy are mutually convertible in the ratio of 778 foot pounds for one
British thermal unit. This law, algebraically expressed, is W = JH; W being the work done in
foot pounds, H being the heat in B. t. u., and J being Joules equivalent. Thus 1000 B. t. u.’s
would be capable of doing 1000 × 778 = 778000 foot pounds of work.
Specific Heat —The specific heat of a substance is the quantity of heat expressed in thermal
units required to raise or lower the temperature of a unit weight of any substance at a given
temperature one degree. This quantity will vary for different substances For example, it requires
about 16 B. t. u. to raise the temperature of one [Pg 84] pound of ice 32 degrees or 0.5 B. t. u. to
raise it one degree, while it requires approximately 180 B. t. u. to raise the temperature of one
pound of water 180 degrees or one B. t. u. for one degree.
If then, a pound of water be considered as a standard, the ratio of the amount of heat required to
raise a similar unit of any other substance one degree, to the amount required to raise a pound
of water one degree is known as the specific heat of that substance. Thus since one pound of
water required one B. t. u. to raise its temperature one degree, and one pound of ice requires
about 0.5 degrees to raise its temperature one degree, the ratio is 0.5 which is the specific heat
of ice. To be exact, the specific heat of ice is 0.504, hence 32 degrees × 0.504 = 16.128 B. t. u.
would be required to raise the temperature of one pound of ice from 0 to 32 degrees. For solids,
at ordinary temperatures, the specific heat may be considered a constant for each individual
substance, although it is variable for high temperatures. In the case of gases a distinction must
be made between specific heat at constant volume, and at constant pressure.
Where specific heat is stated alone, specific heat at ordinary temperature is implied, and mean
specific heat refers to the average value of this quantity between the temperatures named.
The specific heat of a mixture of gases is obtained by multiplying the specific heat of each
constituent gas by the percentage by weight of that gas in the mixture, and dividing the sum of
the products by 100. The specific heat of a gas whose composition by weight is CO 2 , 13 per
cent; CO, 0.4 per cent; O, 8 per cent; N, 78.6 per cent, is found as follows:
CO 2 13.0 × 0.2170 = 2.82100
CO 0.4 × 0.2479 = 0.09916
O 8.0 × 0.2175 = 1.74000
N 78.6 × 0.2438 = 19.16268
–––– –––––––
100.0 = 23.82284
and 23.8228 ÷ 100 = 0.238 = specific heat of the gas.
Page 115
The specific heats of various solids, liquids and gases are given in Table 4 .
Sensible Heat —The heat utilized in raising the temperature of a body, as that in raising the
temperature of water from 32 degrees up to the boiling point, is termed sensible heat. In the
case of water, the sensible heat required to raise its temperature from the freezing point to the
boiling point corresponding to the pressure under which ebullition occurs, is termed the heat of
the liquid.
Latent Heat —Latent heat is the heat which apparently disappears in producing some change
in the condition of a body without increasing its temperature If heat be added to ice at freezing
temperature, the ice will melt but its temperature will not be raised. The heat so utilized in
changing the condition of the ice is the latent heat and in this particular case is known as the
latent heat of fusion. If heat be added to water at 212 degrees under atmospheric pressure, the
water will not become hotter but will be evaporated into steam, the temperature of which will
also be 212 degrees. The heat so utilized is called the latent heat of evaporation and is the heat
which apparently disappears in causing the substance to pass from a liquid to a gaseous state.
[Pg 85]
TABLE 4
SPECIFIC HEATS OF VARIOUS SUBSTANCES
SOLIDS
Temperature Temperature
[2] [2]
Specific Heat Specific Heat
Degrees Degrees
Fahrenheit Fahrenheit
Glass
(normal
Copper 59 –460 .0951 66 – 212 .1988
ther. 16 III
)
Gold 32 –212 .0316 Lead 59 .0299
Wrought
59 –212 .1152 Platinum 32 – 212 .0323
Iron
Cast Iron 68 –212 .1189 Silver 32 – 212 .0559
Steel (soft) 68 –208 .1175 Tin -105 – 64 .0518
Steel (hard) 68 –208 .1165 Ice .5040
Sulphur
Zinc 32 –212 .0935 (newly .2025
fused)
Brass
32 .0883
(yellow)
LIQUIDS
Temperature Specific Heat Temperature Specific Heat
[2] [2]
Sensible Heat —The heat utilized in raising the temperature of a body, as that in raising the
temperature of water from 32 degrees up to the boiling point, is termed sensible heat. In the
case of water, the sensible heat required to raise its temperature from the freezing point to the
boiling point corresponding to the pressure under which ebullition occurs, is termed the heat of
the liquid.
Latent Heat —Latent heat is the heat which apparently disappears in producing some change
in the condition of a body without increasing its temperature If heat be added to ice at freezing
temperature, the ice will melt but its temperature will not be raised. The heat so utilized in
changing the condition of the ice is the latent heat and in this particular case is known as the
latent heat of fusion. If heat be added to water at 212 degrees under atmospheric pressure, the
water will not become hotter but will be evaporated into steam, the temperature of which will
also be 212 degrees. The heat so utilized is called the latent heat of evaporation and is the heat
which apparently disappears in causing the substance to pass from a liquid to a gaseous state.
[Pg 85]
TABLE 4
SPECIFIC HEATS OF VARIOUS SUBSTANCES
SOLIDS
Temperature Temperature
[2] [2]
Specific Heat Specific Heat
Degrees Degrees
Fahrenheit Fahrenheit
Glass
(normal
Copper 59 –460 .0951 66 – 212 .1988
ther. 16 III
)
Gold 32 –212 .0316 Lead 59 .0299
Wrought
59 –212 .1152 Platinum 32 – 212 .0323
Iron
Cast Iron 68 –212 .1189 Silver 32 – 212 .0559
Steel (soft) 68 –208 .1175 Tin -105 – 64 .0518
Steel (hard) 68 –208 .1165 Ice .5040
Sulphur
Zinc 32 –212 .0935 (newly .2025
fused)
Brass
32 .0883
(yellow)
LIQUIDS
Temperature Specific Heat Temperature Specific Heat
[2] [2]
Page 116
Degrees Degrees
Fahrenheit Fahrenheit
Sulphur
Water [3] 59 1.00000 246 – 297 .23500
(melted)
Tin
Alcohol 32 .54750 .06370
(melted)
Sea Water
176 .76940 (sp. gr. 64 .98000
1.0043)
Sea Water
Mercury 32 .03346 (sp. gr. 64 .90300
1.0463)
Oil of
Benzol 50 .40660 32 .41100
Turpentine
122 .45020 Petroleum 64 – 210 .49800
Sulphuric
Glycerine 59 –102 .57600 68 – 133 .33630
Acid
Lead
to 360 .04100
(Melted)
GASES
Temperature Specific Specific Temperature Specific Specific
[2] Heat at Heat at [2] Heat at Heat at
Degrees Constant Constant Degrees Constant Constant
Fahrenheit Pressure Volume Fahrenheit Pressure Volume
Carbon
Air 32 –392 .2375 .1693 41 – 208 .2425 .1728
Monoxide
Carbon
Oxygen 44 –405 .2175 .1553 52 – 417 .2169 .1535
Dioxide
Nitrogen 32 –392 .2438 .1729 Methane 64 – 406 .5929 .4505
Blast Fur.
Hydrogen 54 –388 3.4090 2.4141 Gas ... .2277 …
(approx.)
Superheated Flue gas
See table 25 ... .2400 …
Steam (approx.)
Latent heat is not lost, but reappears whenever the substances pass through a reverse cycle,
from a gaseous to a liquid, or from a liquid to a solid state. It may, therefore, be defined as
stated, as the heat which apparently disappears, or is lost to thermometric measurement, when
the molecular constitution of a body is being changed. Latent heat is expended in performing
the work of overcoming the molecular cohesion of the particles of the substance and in
overcoming the resistance of external pressure to change of volume of the heated body. Latent
heat of evaporation, therefore, may be said to consist of internal and external heat, the former
being [Pg 86] utilized in overcoming the molecular resistance of the water in changing to steam,
while the latter is expended in overcoming any resistance to the increase of its volume during
formation. In evaporating a pound of water at 212 degrees to steam at 212 degrees, 897.6 B. t.
Fahrenheit Fahrenheit
Sulphur
Water [3] 59 1.00000 246 – 297 .23500
(melted)
Tin
Alcohol 32 .54750 .06370
(melted)
Sea Water
176 .76940 (sp. gr. 64 .98000
1.0043)
Sea Water
Mercury 32 .03346 (sp. gr. 64 .90300
1.0463)
Oil of
Benzol 50 .40660 32 .41100
Turpentine
122 .45020 Petroleum 64 – 210 .49800
Sulphuric
Glycerine 59 –102 .57600 68 – 133 .33630
Acid
Lead
to 360 .04100
(Melted)
GASES
Temperature Specific Specific Temperature Specific Specific
[2] Heat at Heat at [2] Heat at Heat at
Degrees Constant Constant Degrees Constant Constant
Fahrenheit Pressure Volume Fahrenheit Pressure Volume
Carbon
Air 32 –392 .2375 .1693 41 – 208 .2425 .1728
Monoxide
Carbon
Oxygen 44 –405 .2175 .1553 52 – 417 .2169 .1535
Dioxide
Nitrogen 32 –392 .2438 .1729 Methane 64 – 406 .5929 .4505
Blast Fur.
Hydrogen 54 –388 3.4090 2.4141 Gas ... .2277 …
(approx.)
Superheated Flue gas
See table 25 ... .2400 …
Steam (approx.)
Latent heat is not lost, but reappears whenever the substances pass through a reverse cycle,
from a gaseous to a liquid, or from a liquid to a solid state. It may, therefore, be defined as
stated, as the heat which apparently disappears, or is lost to thermometric measurement, when
the molecular constitution of a body is being changed. Latent heat is expended in performing
the work of overcoming the molecular cohesion of the particles of the substance and in
overcoming the resistance of external pressure to change of volume of the heated body. Latent
heat of evaporation, therefore, may be said to consist of internal and external heat, the former
being [Pg 86] utilized in overcoming the molecular resistance of the water in changing to steam,
while the latter is expended in overcoming any resistance to the increase of its volume during
formation. In evaporating a pound of water at 212 degrees to steam at 212 degrees, 897.6 B. t.
Page 117
u. are expended as internal latent heat and 72.8 B. t. u. as external latent heat. For a more
detailed description of the changes brought about in water by sensible and latent heat, the
reader is again referred to the chapter on “The Theory of Steam Making”.
TABLE 5 Ebullition —The temperature of
ebullition of any liquid, or its boiling
BOILING POINTS AT ATMOSPHERIC point, may be defined as the
PRESSURE temperature which exists where the
Degrees Degrees addition of heat to the liquid no
Fahrenheit Fahrenheit longer increases its temperature, the
Ammonia 140 Water 212 heat added being absorbed or utilized
Bromine 145 Average Sea Water 213.2 in converting the liquid into vapor.
This temperature is dependent upon
Alcohol 173 Saturated Brine 226
the pressure under which the liquid is
Benzine 212 Mercury 680 evaporated, being higher as the
pressure is greater.
Total Heat of Evaporation —The quantity of heat required to raise a unit of any liquid from
the freezing point to any given temperature, and to entirely evaporate it at that temperature, is
the total heat of evaporation of the liquid for that temperature. It is the sum of the heat of the
liquid and the latent heat of evaporation.
To recapitulate, the heat added to a body is divided as follows:
Total heat = Heat to change the temperature + heat to overcome the molecular cohesion + heat
to overcome the external pressure resisting an increase of volume of the body.
Where water is converted into steam, this total heat is divided as follows:
Total heat = Heat to change the temperature of the water + heat to separate the molecules of the
water + heat to overcome resistance to increase in volume of the steam,
= Heat of the liquid + internal latent heat + external latent heat,
= Heat of the liquid + total latent heat of steam,
= Total heat of evaporation.
The steam tables given on pages 122 to 127 give the heat of the liquid and the total latent heat
through a wide range of temperatures.
Gases —When heat is added to gases there is no internal work done; hence the total heat is that
required to change the temperature plus that required to do the external work. If the gas is not
allowed to expand but is preserved at constant volume, the entire heat added is that required to
change the temperature only.
Linear Expansion of Substances by Heat —To find the increase in the length of a bar of any
material due to an increase of temperature, multiply the number of degrees of increase in
temperature by the coefficient of expansion for one degree and by the length of the bar. Where
the coefficient of expansion is given for 100 degrees, as in Table 6 , the result should be divided
detailed description of the changes brought about in water by sensible and latent heat, the
reader is again referred to the chapter on “The Theory of Steam Making”.
TABLE 5 Ebullition —The temperature of
ebullition of any liquid, or its boiling
BOILING POINTS AT ATMOSPHERIC point, may be defined as the
PRESSURE temperature which exists where the
Degrees Degrees addition of heat to the liquid no
Fahrenheit Fahrenheit longer increases its temperature, the
Ammonia 140 Water 212 heat added being absorbed or utilized
Bromine 145 Average Sea Water 213.2 in converting the liquid into vapor.
This temperature is dependent upon
Alcohol 173 Saturated Brine 226
the pressure under which the liquid is
Benzine 212 Mercury 680 evaporated, being higher as the
pressure is greater.
Total Heat of Evaporation —The quantity of heat required to raise a unit of any liquid from
the freezing point to any given temperature, and to entirely evaporate it at that temperature, is
the total heat of evaporation of the liquid for that temperature. It is the sum of the heat of the
liquid and the latent heat of evaporation.
To recapitulate, the heat added to a body is divided as follows:
Total heat = Heat to change the temperature + heat to overcome the molecular cohesion + heat
to overcome the external pressure resisting an increase of volume of the body.
Where water is converted into steam, this total heat is divided as follows:
Total heat = Heat to change the temperature of the water + heat to separate the molecules of the
water + heat to overcome resistance to increase in volume of the steam,
= Heat of the liquid + internal latent heat + external latent heat,
= Heat of the liquid + total latent heat of steam,
= Total heat of evaporation.
The steam tables given on pages 122 to 127 give the heat of the liquid and the total latent heat
through a wide range of temperatures.
Gases —When heat is added to gases there is no internal work done; hence the total heat is that
required to change the temperature plus that required to do the external work. If the gas is not
allowed to expand but is preserved at constant volume, the entire heat added is that required to
change the temperature only.
Linear Expansion of Substances by Heat —To find the increase in the length of a bar of any
material due to an increase of temperature, multiply the number of degrees of increase in
temperature by the coefficient of expansion for one degree and by the length of the bar. Where
the coefficient of expansion is given for 100 degrees, as in Table 6 , the result should be divided
Page 118
by 100. The expansion of metals [Pg 87] per one degree rise of temperature increases slightly as
high temperatures are reached, but for all practical purposes it may be assumed to be constant
for a given metal.
TABLE 6
LINEAL EXPANSION OF SOLIDS AT ORDINARY TEMPERATURES
(Tabular values represent increase per foot per 100 degrees increase in temperature, Fahrenheit
or centigrade)
Coefficient per Coefficient per
Temperature Conditions 100 100
[4] Degrees Degrees
Substance Degrees Fahrenheit Fahrenheit Centigrade
Brass (cast) 32 to 212 .001042 .001875
Brass (wire) 32 to 212 .001072 .001930
Copper 32 to 212 .000926 .001666
Glass (English flint) 32 to 212 .000451 .000812
Glass (French flint) 32 to 212 .000484 .000872
Gold 32 to 212 .000816 .001470
Granite (average) 32 to 212 .000482 .000868
Iron (cast) 104 .000589 .001061
Iron (soft forged) 0 to 212 .000634 .001141
Iron (wire) 32 to 212 .000800 .001440
Lead 32 to 212 .001505 .002709
Mercury 32 to 212 .009984 [5] .017971
Platinum 104 .000499 .000899
Limestone 32 to 212 .000139 .000251
Silver 104 .001067 .001921
Steel (Bessemer rolled,
0 to 212 .00056 .00101
hard)
Steel (Bessemer rolled,
0 to 212 .00063 .00117
soft)
Steel (cast, French) 104 .000734 .001322
Steel (cast annealed,
104 .000608 .001095
English)
High Temperature Measurements —The temperatures to be dealt with in steam-boiler practice
range from those of ordinary air and steam to the temperatures of burning fuel. The gases of
combustion, originally at the temperature of the furnace, cool as they pass through each
successive bank of tubes in the boiler, to nearly the temperature of the steam, resulting in a wide
range of temperatures through which definite measurements are sometimes required.
Of the different methods devised for ascertaining these temperatures, some of the most
important are as follows:
high temperatures are reached, but for all practical purposes it may be assumed to be constant
for a given metal.
TABLE 6
LINEAL EXPANSION OF SOLIDS AT ORDINARY TEMPERATURES
(Tabular values represent increase per foot per 100 degrees increase in temperature, Fahrenheit
or centigrade)
Coefficient per Coefficient per
Temperature Conditions 100 100
[4] Degrees Degrees
Substance Degrees Fahrenheit Fahrenheit Centigrade
Brass (cast) 32 to 212 .001042 .001875
Brass (wire) 32 to 212 .001072 .001930
Copper 32 to 212 .000926 .001666
Glass (English flint) 32 to 212 .000451 .000812
Glass (French flint) 32 to 212 .000484 .000872
Gold 32 to 212 .000816 .001470
Granite (average) 32 to 212 .000482 .000868
Iron (cast) 104 .000589 .001061
Iron (soft forged) 0 to 212 .000634 .001141
Iron (wire) 32 to 212 .000800 .001440
Lead 32 to 212 .001505 .002709
Mercury 32 to 212 .009984 [5] .017971
Platinum 104 .000499 .000899
Limestone 32 to 212 .000139 .000251
Silver 104 .001067 .001921
Steel (Bessemer rolled,
0 to 212 .00056 .00101
hard)
Steel (Bessemer rolled,
0 to 212 .00063 .00117
soft)
Steel (cast, French) 104 .000734 .001322
Steel (cast annealed,
104 .000608 .001095
English)
High Temperature Measurements —The temperatures to be dealt with in steam-boiler practice
range from those of ordinary air and steam to the temperatures of burning fuel. The gases of
combustion, originally at the temperature of the furnace, cool as they pass through each
successive bank of tubes in the boiler, to nearly the temperature of the steam, resulting in a wide
range of temperatures through which definite measurements are sometimes required.
Of the different methods devised for ascertaining these temperatures, some of the most
important are as follows:
Page 119
1st. Mercurial pyrometers for temperatures up to 1000 degrees Fahrenheit.
2nd. Expansion pyrometers for temperatures up to 1500 degrees Fahrenheit.
3rd. Calorimetry for temperatures up to 2000 degrees Fahrenheit.
4th. Thermo-electric pyrometers for temperatures up to 2900 degrees Fahrenheit.
5th. Melting points of metal which flow at various temperatures up to the melting point of
platinum 3227 degrees Fahrenheit.
6th. Radiation pyrometers for temperatures up to 3600 degrees Fahrenheit.
7th. Optical pyrometers capable of measuring temperatures up to 12,600 degrees
Fahrenheit. [6] For ordinary boiler practice however, their range is 1600 to 3600 degrees
Fahrenheit. [Pg 88]
228 Horse-power Babcock & Wilcox Boiler, Installed at the Wentworth Institute, Boston,
Mass.
[Pg 89] Table 7 gives the degree of accuracy of high temperature measurements.
2nd. Expansion pyrometers for temperatures up to 1500 degrees Fahrenheit.
3rd. Calorimetry for temperatures up to 2000 degrees Fahrenheit.
4th. Thermo-electric pyrometers for temperatures up to 2900 degrees Fahrenheit.
5th. Melting points of metal which flow at various temperatures up to the melting point of
platinum 3227 degrees Fahrenheit.
6th. Radiation pyrometers for temperatures up to 3600 degrees Fahrenheit.
7th. Optical pyrometers capable of measuring temperatures up to 12,600 degrees
Fahrenheit. [6] For ordinary boiler practice however, their range is 1600 to 3600 degrees
Fahrenheit. [Pg 88]
228 Horse-power Babcock & Wilcox Boiler, Installed at the Wentworth Institute, Boston,
Mass.
[Pg 89] Table 7 gives the degree of accuracy of high temperature measurements.
Page 120
Mercurial Pyrometers —At atmospheric TABLE 7
pressure mercury boils at 676 degrees
Fahrenheit and even at lower ACCURACY OF HIGH TEMPERATURE
temperatures the mercury in MEASUREMENTS [7]
thermometers will be distilled and will Centigrade Fahrenheit
collect in the upper part of the stem. Accuracy Accuracy
Therefore, for temperatures much above Temperature Plus or Temperature Plus or
400 degrees Fahrenheit, some inert gas, Range Minus Range Minus
such as nitrogen or carbon dioxide, must Degrees Degrees
be forced under pressure into the upper 200– 500 0.5 392– 932 0.9
part of the thermometer stem. The
500– 800 2.0 932– 1472 3.6
pressure at 600 degrees Fahrenheit is
about 15 pounds, or slightly above that of 800– 1100 3.0 1472– 2012 5.4
the atmosphere, at 850 degrees about 70 1100 – 1600 15.0 2012– 2912 27.0
pounds, and at 1000 degrees about 300 1600– 2000 25.0 2912– 3632 45.0
pounds.
Flue-gas temperatures are nearly always taken with mercurial thermometers as they are the
most accurate and are easy to read and manipulate. Care must be taken that the bulb of the
instrument projects into the path of the moving gases in order that the temperature may truly
represent the flue gas temperature. No readings should be considered until the thermometer has
been in place long enough to heat it up to the full temperature of the gases.
Expansion Pyrometers —Brass expands about 50 per cent more than iron and in both brass and
iron the expansion is nearly proportional to the increase in temperature. This phenomenon is
utilized in expansion pyrometers by enclosing a brass rod in an iron pipe, one end of the rod
being rigidly attached to a cap at the end of the pipe, while the other is connected by a
multiplying gear to a pointer moving around a graduated dial. The whole length of the
expansion piece must be at a uniform temperature before a correct reading can be obtained.
This fact, together with the lost motion which is likely to exist in the mechanism connected to
the pointer, makes the expansion pyrometer unreliable; it should be used only when its
limitations are thoroughly understood and it should be carefully calibrated. Unless the brass and
iron are known to be of the same temperature, its action will be anomalous: for instance, if it be
allowed to cool after being exposed to a high temperature, the needle will rise before it begins
to fall. Similarly, a rise in temperature is first shown by the instrument as a fall. The explanation
is that the iron, being on the outside, heats or cools more quickly than the brass.
Calorimetry —This method derives its name from the fact that the process is the same as the
determination of the specific heat of a substance by the water calorimeter, except that in one
case the temperature is known and the specific heat is required, while in the other the specific
heat is known and the temperature is required. The temperature is found as follows:
A given weight of some substance such as iron, nickel or fire brick, is heated to the unknown
temperature and then plunged into water and the rise in temperature noted.
[Pg 90]
pressure mercury boils at 676 degrees
Fahrenheit and even at lower ACCURACY OF HIGH TEMPERATURE
temperatures the mercury in MEASUREMENTS [7]
thermometers will be distilled and will Centigrade Fahrenheit
collect in the upper part of the stem. Accuracy Accuracy
Therefore, for temperatures much above Temperature Plus or Temperature Plus or
400 degrees Fahrenheit, some inert gas, Range Minus Range Minus
such as nitrogen or carbon dioxide, must Degrees Degrees
be forced under pressure into the upper 200– 500 0.5 392– 932 0.9
part of the thermometer stem. The
500– 800 2.0 932– 1472 3.6
pressure at 600 degrees Fahrenheit is
about 15 pounds, or slightly above that of 800– 1100 3.0 1472– 2012 5.4
the atmosphere, at 850 degrees about 70 1100 – 1600 15.0 2012– 2912 27.0
pounds, and at 1000 degrees about 300 1600– 2000 25.0 2912– 3632 45.0
pounds.
Flue-gas temperatures are nearly always taken with mercurial thermometers as they are the
most accurate and are easy to read and manipulate. Care must be taken that the bulb of the
instrument projects into the path of the moving gases in order that the temperature may truly
represent the flue gas temperature. No readings should be considered until the thermometer has
been in place long enough to heat it up to the full temperature of the gases.
Expansion Pyrometers —Brass expands about 50 per cent more than iron and in both brass and
iron the expansion is nearly proportional to the increase in temperature. This phenomenon is
utilized in expansion pyrometers by enclosing a brass rod in an iron pipe, one end of the rod
being rigidly attached to a cap at the end of the pipe, while the other is connected by a
multiplying gear to a pointer moving around a graduated dial. The whole length of the
expansion piece must be at a uniform temperature before a correct reading can be obtained.
This fact, together with the lost motion which is likely to exist in the mechanism connected to
the pointer, makes the expansion pyrometer unreliable; it should be used only when its
limitations are thoroughly understood and it should be carefully calibrated. Unless the brass and
iron are known to be of the same temperature, its action will be anomalous: for instance, if it be
allowed to cool after being exposed to a high temperature, the needle will rise before it begins
to fall. Similarly, a rise in temperature is first shown by the instrument as a fall. The explanation
is that the iron, being on the outside, heats or cools more quickly than the brass.
Calorimetry —This method derives its name from the fact that the process is the same as the
determination of the specific heat of a substance by the water calorimeter, except that in one
case the temperature is known and the specific heat is required, while in the other the specific
heat is known and the temperature is required. The temperature is found as follows:
A given weight of some substance such as iron, nickel or fire brick, is heated to the unknown
temperature and then plunged into water and the rise in temperature noted.
[Pg 90]
Page 121
If X = temperature to be measured, w = weight of heated body in pounds, W = weight of water
in pounds, T = final temperature of water, t = difference between initial and final temperatures
of water, s = known specific heat of body. Then X = T + W t ÷ w s
Any temperatures secured by this method are affected by so many sources of error that the
results are very approximate.
Thermo-electric Pyrometers —When wires of two different metals are joined at one end and
heated, an electromotive force will be set up between the free ends of the wires. Its amount will
depend upon the composition of the wires and the difference in temperature between the two. If
a delicate galvanometer of high resistance be connected to the “thermal couple”, as it is called,
the deflection of the needle, after a careful calibration, will indicate the temperature very
accurately.
In the thermo-electric pyrometer of Le Chatelier, the wires used are platinum and a 10 per cent
alloy of platinum and rhodium, enclosed in porcelain tubes to protect them from the oxidizing
influence of the furnace gases. The couple with its protecting tubes is called an “element”. The
elements are made in different lengths to suit conditions.
It is not necessary for accuracy to expose the whole length of the element to the temperature to
be measured, as the electromotive force depends only upon the temperature of the juncture at
the closed end of the protecting tube and that of the cold end of the element. The galvanometer
can be located at any convenient point, since the length of the wires leading to it simply alter
the resistance of the circuit, for which allowance may be made.
The advantages of the thermo-electric pyrometer are accuracy over a wide range of
temperatures, continuity of readings, and the ease with which observations can be taken. Its
disadvantages are high first cost and, in some cases, extreme delicacy.
Melting Points of Metals —The approximate temperature of a furnace or flue may be
determined, if so desired, by introducing certain metals of which the melting points are known.
The more common metals form a series in which the respective melting points differ by 100 to
200 degrees Fahrenheit, and by using these in order, the temperature can be fixed between the
melting points of some two of them. This method lacks accuracy, but it suffices for
determinations where approximate readings are satisfactory.
The approximate melting points of certain metals that may be used for determinations of this
nature are given in Table 8 .
Radiation Pyrometers —These are similar to thermo-electric pyrometers in that a thermo-
couple is employed. The heat rays given out by the hot body fall on a concave mirror and are
brought to a focus at a point at which is placed the junction of a thermo-couple. The
temperature readings are obtained from an indicator similar to that used with thermo-electric
pyrometers.
Optical Pyrometers —Of the optical pyrometers the Wanner is perhaps the most reliable. The
principle on which this instrument is constructed is that of comparing the quantity of light
emanating from the heated body with a constant source of light, in this case a two-volt osmium
in pounds, T = final temperature of water, t = difference between initial and final temperatures
of water, s = known specific heat of body. Then X = T + W t ÷ w s
Any temperatures secured by this method are affected by so many sources of error that the
results are very approximate.
Thermo-electric Pyrometers —When wires of two different metals are joined at one end and
heated, an electromotive force will be set up between the free ends of the wires. Its amount will
depend upon the composition of the wires and the difference in temperature between the two. If
a delicate galvanometer of high resistance be connected to the “thermal couple”, as it is called,
the deflection of the needle, after a careful calibration, will indicate the temperature very
accurately.
In the thermo-electric pyrometer of Le Chatelier, the wires used are platinum and a 10 per cent
alloy of platinum and rhodium, enclosed in porcelain tubes to protect them from the oxidizing
influence of the furnace gases. The couple with its protecting tubes is called an “element”. The
elements are made in different lengths to suit conditions.
It is not necessary for accuracy to expose the whole length of the element to the temperature to
be measured, as the electromotive force depends only upon the temperature of the juncture at
the closed end of the protecting tube and that of the cold end of the element. The galvanometer
can be located at any convenient point, since the length of the wires leading to it simply alter
the resistance of the circuit, for which allowance may be made.
The advantages of the thermo-electric pyrometer are accuracy over a wide range of
temperatures, continuity of readings, and the ease with which observations can be taken. Its
disadvantages are high first cost and, in some cases, extreme delicacy.
Melting Points of Metals —The approximate temperature of a furnace or flue may be
determined, if so desired, by introducing certain metals of which the melting points are known.
The more common metals form a series in which the respective melting points differ by 100 to
200 degrees Fahrenheit, and by using these in order, the temperature can be fixed between the
melting points of some two of them. This method lacks accuracy, but it suffices for
determinations where approximate readings are satisfactory.
The approximate melting points of certain metals that may be used for determinations of this
nature are given in Table 8 .
Radiation Pyrometers —These are similar to thermo-electric pyrometers in that a thermo-
couple is employed. The heat rays given out by the hot body fall on a concave mirror and are
brought to a focus at a point at which is placed the junction of a thermo-couple. The
temperature readings are obtained from an indicator similar to that used with thermo-electric
pyrometers.
Optical Pyrometers —Of the optical pyrometers the Wanner is perhaps the most reliable. The
principle on which this instrument is constructed is that of comparing the quantity of light
emanating from the heated body with a constant source of light, in this case a two-volt osmium
Page 122
lamp. The lamp is placed at one end of an optical tube, while at the other an eyepiece is
provided and a scale. A battery of cells furnishes the current for the lamp. On looking through
the pyrometer, a circle [Pg 91] of red light appears, divided into distinct halves of different
intensities. Adjustment may be made so that the two halves appear alike and a reading is then
taken from the scale. The temperatures are obtained from a table of temperatures corresponding
to scale readings. For standardizing the osmium lamp, an amylacetate lamp, is provided with a
stand for holding the optical tube.
TABLE 8
APPROXIMATE MELTING POINTS OF METALS [8]
Temperature Temperature
Metal Metal
Degrees Fahrenheit Degrees Fahrenheit
Wrought Iron 2737 Lead 621
Pig Iron (gray) 2190-2327 Bismuth 498
Cast Iron (white) 2075 Tin 449
Steel 2460-2550 Platinum 3191
Steel (cast) 2500 Gold 1946
Copper 1981 Silver 1762
Zinc 786 Aluminum 1216
Antimony 1166
Determination of Temperature from Character of Emitted Light —As a further means of
determining approximately the temperature of a furnace, Table 9 , compiled by Messrs. White
& Taylor, may be of service. The color at a given temperature is approximately the same for all
kinds of combustibles under similar conditions.
TABLE 9
CHARACTER OF EMITTED LIGHT AND CORRESPONDING
APPROXIMATE TEMPERATURE [9]
Temperature Temperature
Character of Emitted Light Degrees Character of Emitted Light Degrees
Fahrenheit Fahrenheit
Dark red, blood red, low red 1050 Light orange 1725
Dark cherry red 1175 Yellow 1825
Cherry, full red 1375 Light yellow 1975
Light cherry, bright cherry, light red 1550 White 2200
Orange 1650
FOOTNOTES
[2] When one temperature alone is given the “true” specific heat is given; otherwise the value is the
“mean” specific heat for the range of temperature given.
[3] For variation, see Table 13 .
provided and a scale. A battery of cells furnishes the current for the lamp. On looking through
the pyrometer, a circle [Pg 91] of red light appears, divided into distinct halves of different
intensities. Adjustment may be made so that the two halves appear alike and a reading is then
taken from the scale. The temperatures are obtained from a table of temperatures corresponding
to scale readings. For standardizing the osmium lamp, an amylacetate lamp, is provided with a
stand for holding the optical tube.
TABLE 8
APPROXIMATE MELTING POINTS OF METALS [8]
Temperature Temperature
Metal Metal
Degrees Fahrenheit Degrees Fahrenheit
Wrought Iron 2737 Lead 621
Pig Iron (gray) 2190-2327 Bismuth 498
Cast Iron (white) 2075 Tin 449
Steel 2460-2550 Platinum 3191
Steel (cast) 2500 Gold 1946
Copper 1981 Silver 1762
Zinc 786 Aluminum 1216
Antimony 1166
Determination of Temperature from Character of Emitted Light —As a further means of
determining approximately the temperature of a furnace, Table 9 , compiled by Messrs. White
& Taylor, may be of service. The color at a given temperature is approximately the same for all
kinds of combustibles under similar conditions.
TABLE 9
CHARACTER OF EMITTED LIGHT AND CORRESPONDING
APPROXIMATE TEMPERATURE [9]
Temperature Temperature
Character of Emitted Light Degrees Character of Emitted Light Degrees
Fahrenheit Fahrenheit
Dark red, blood red, low red 1050 Light orange 1725
Dark cherry red 1175 Yellow 1825
Cherry, full red 1375 Light yellow 1975
Light cherry, bright cherry, light red 1550 White 2200
Orange 1650
FOOTNOTES
[2] When one temperature alone is given the “true” specific heat is given; otherwise the value is the
“mean” specific heat for the range of temperature given.
[3] For variation, see Table 13 .
Page 123
[4] Where range of temperature is given, coefficient is mean over range.
[5] Coefficient of cubical expansion.
[6] Le Chatelier’s Investigations.
[7] Burgess-Le Chatelier.
[8] For accuracy of high temperature measurements, see Table 7 .
[9] Messrs. White & Taylor Trans. A. S. M. E., Vol. XXI, 1900.
[5] Coefficient of cubical expansion.
[6] Le Chatelier’s Investigations.
[7] Burgess-Le Chatelier.
[8] For accuracy of high temperature measurements, see Table 7 .
[9] Messrs. White & Taylor Trans. A. S. M. E., Vol. XXI, 1900.
Page 124
[Pg 92]
Page 125
THE THEORY OF STEAM MAKING
[Extracts from a Lecture delivered by George H. Babcock, at Cornell
University, 1887[10]]
The chemical compound known as H2O exists in three states or conditions
—ice, water and steam; the only difference between these states or
conditions is in the presence or absence of a quantity of energy exhibited
partly in the form of heat and partly in molecular activity, which, for want
of a better name, we are accustomed to call “latent heat”; and to transform it
from one state to another we have only to supply or extract heat. For
instance, if we take a quantity of ice, say one pound, at absolute zero[11] and
supply heat, the first effect is to raise its temperature until it arrives at a
point 492 Fahrenheit degrees above the starting point. Here it stops growing
warmer, though we keep on adding heat. It, however, changes from ice to
water, and when we have added sufficient heat to have made it, had it
remained ice, 283 degrees hotter or a temperature of 315 degrees
Fahrenheit’s thermometer, it has all become water, at the same temperature
at which it commenced to change, namely, 492 degrees above absolute zero,
or 32 degrees by Fahrenheit’s scale. Let us still continue to add heat, and it
will now grow warmer again, though at a slower rate—that is, it now takes
about double the quantity of heat to raise the pound one degree that it did
before—until it reaches a temperature of 212 degrees Fahrenheit, or 672
degrees absolute (assuming that we are at the level of the sea). Here we find
another critical point. However much more heat we may apply, the water, as
water, at that pressure, cannot be heated any hotter, but changes on the
addition of heat to steam; and it is not until we have added heat enough to
have raised the temperature of the water 966 degrees, or to 1,178 degrees by
Fahrenheit’s thermometer (presuming for the moment that its specific heat
has not changed since it became water), that it has all become steam, which
steam, nevertheless, is at the temperature of 212 degrees, at which the water
began to change. Thus over four-fifths of the heat which has been added to
the water has disappeared, or become insensible in the steam to any of our
instruments.
[Extracts from a Lecture delivered by George H. Babcock, at Cornell
University, 1887[10]]
The chemical compound known as H2O exists in three states or conditions
—ice, water and steam; the only difference between these states or
conditions is in the presence or absence of a quantity of energy exhibited
partly in the form of heat and partly in molecular activity, which, for want
of a better name, we are accustomed to call “latent heat”; and to transform it
from one state to another we have only to supply or extract heat. For
instance, if we take a quantity of ice, say one pound, at absolute zero[11] and
supply heat, the first effect is to raise its temperature until it arrives at a
point 492 Fahrenheit degrees above the starting point. Here it stops growing
warmer, though we keep on adding heat. It, however, changes from ice to
water, and when we have added sufficient heat to have made it, had it
remained ice, 283 degrees hotter or a temperature of 315 degrees
Fahrenheit’s thermometer, it has all become water, at the same temperature
at which it commenced to change, namely, 492 degrees above absolute zero,
or 32 degrees by Fahrenheit’s scale. Let us still continue to add heat, and it
will now grow warmer again, though at a slower rate—that is, it now takes
about double the quantity of heat to raise the pound one degree that it did
before—until it reaches a temperature of 212 degrees Fahrenheit, or 672
degrees absolute (assuming that we are at the level of the sea). Here we find
another critical point. However much more heat we may apply, the water, as
water, at that pressure, cannot be heated any hotter, but changes on the
addition of heat to steam; and it is not until we have added heat enough to
have raised the temperature of the water 966 degrees, or to 1,178 degrees by
Fahrenheit’s thermometer (presuming for the moment that its specific heat
has not changed since it became water), that it has all become steam, which
steam, nevertheless, is at the temperature of 212 degrees, at which the water
began to change. Thus over four-fifths of the heat which has been added to
the water has disappeared, or become insensible in the steam to any of our
instruments.
Page 126
It follows that if we could reduce steam at atmospheric pressure to water,
without loss of heat, the heat stored within it would cause the water to be
red hot; and if we could further change it to a solid, like ice, without loss of
heat, the solid would be white hot, or hotter than melted steel—it being
assumed, of course, that the specific heat of the water and ice remain
normal, or the same as they respectively are at the freezing point.
After steam has been formed, a further addition of heat increases the
temperature again at a much faster ratio to the quantity of heat added, which
ratio also varies according as we maintain a constant pressure or a constant
volume; and I am not aware that any other critical point exists where this
will cease to be the fact until we arrive at that very high temperature, known
as the point of dissociation, at which it becomes resolved into its original
gases.
The heat which has been absorbed by one pound of water to convert it into
a pound of steam at atmospheric pressure is sufficient to have melted 3
pounds of steel or 13 pounds of gold. This has been transformed into
something besides heat; [Pg 93] stored up to reappear as heat when the
process is reversed. That condition is what we are pleased to call latent heat,
and in it resides mainly the ability of the steam to do work.
The diagram shows graphically the relation of heat to temperature, the
horizontal scale being quantity of heat in British thermal units, and the
vertical temperature in Fahrenheit degrees, both reckoned from absolute
zero and by the usual scale. The dotted lines for ice and water show the
temperature which would have been obtained if the conditions had not
changed. The lines marked “gold” and “steel” show the relation to heat and
temperature and the melting points of these metals. All the inclined lines
would be slightly curved if attention had been paid to the changing specific
heat, but the curvature would be small. It is worth noting that, with one or
two exceptions, the curves of all substances lie between the vertical and that
for water. That is to say, that water has a greater capacity for heat than all
other substances except two, hydrogen and bromine.
In order to generate steam, then, only two steps are required: 1st, procure
the heat, and 2nd, transfer it to the water. Now, you have it laid down as an
axiom that when a body has been transferred or transformed from one place
without loss of heat, the heat stored within it would cause the water to be
red hot; and if we could further change it to a solid, like ice, without loss of
heat, the solid would be white hot, or hotter than melted steel—it being
assumed, of course, that the specific heat of the water and ice remain
normal, or the same as they respectively are at the freezing point.
After steam has been formed, a further addition of heat increases the
temperature again at a much faster ratio to the quantity of heat added, which
ratio also varies according as we maintain a constant pressure or a constant
volume; and I am not aware that any other critical point exists where this
will cease to be the fact until we arrive at that very high temperature, known
as the point of dissociation, at which it becomes resolved into its original
gases.
The heat which has been absorbed by one pound of water to convert it into
a pound of steam at atmospheric pressure is sufficient to have melted 3
pounds of steel or 13 pounds of gold. This has been transformed into
something besides heat; [Pg 93] stored up to reappear as heat when the
process is reversed. That condition is what we are pleased to call latent heat,
and in it resides mainly the ability of the steam to do work.
The diagram shows graphically the relation of heat to temperature, the
horizontal scale being quantity of heat in British thermal units, and the
vertical temperature in Fahrenheit degrees, both reckoned from absolute
zero and by the usual scale. The dotted lines for ice and water show the
temperature which would have been obtained if the conditions had not
changed. The lines marked “gold” and “steel” show the relation to heat and
temperature and the melting points of these metals. All the inclined lines
would be slightly curved if attention had been paid to the changing specific
heat, but the curvature would be small. It is worth noting that, with one or
two exceptions, the curves of all substances lie between the vertical and that
for water. That is to say, that water has a greater capacity for heat than all
other substances except two, hydrogen and bromine.
In order to generate steam, then, only two steps are required: 1st, procure
the heat, and 2nd, transfer it to the water. Now, you have it laid down as an
axiom that when a body has been transferred or transformed from one place
Page 127
or state into another, the
same work has been
done and the same
energy expended,
whatever may have been
the intermediate steps or
conditions, or whatever
the apparatus. Therefore,
when a given quantity of
water at a given
temperature has been
made into steam at a
given temperature, a
certain definite work has
been done, and a certain
amount of energy
expended, from
whatever the heat may
have been obtained, or
whatever boiler may
have been employed for
the purpose.
A pound of coal or any
other fuel has a definite
heat producing capacity, and is capable of evaporating a definite quantity of
water under given conditions. That is the limit beyond which even
perfection cannot go, and yet I have known, and doubtless you have heard
of, cases where inventors have claimed, and so-called engineers have
certified to, much higher results.
The first step in generating steam is in burning the fuel to the best
advantage. A pound of carbon will generate 14,500 British thermal units,
during combustion into carbonic dioxide, and this will be the same,
whatever the temperature or the rapidity at which the combustion may take
place. If possible, we might oxidize it at as slow a rate as that with which
iron rusts or wood rots in the open air, or we might burn it [Pg 94] with the
same work has been
done and the same
energy expended,
whatever may have been
the intermediate steps or
conditions, or whatever
the apparatus. Therefore,
when a given quantity of
water at a given
temperature has been
made into steam at a
given temperature, a
certain definite work has
been done, and a certain
amount of energy
expended, from
whatever the heat may
have been obtained, or
whatever boiler may
have been employed for
the purpose.
A pound of coal or any
other fuel has a definite
heat producing capacity, and is capable of evaporating a definite quantity of
water under given conditions. That is the limit beyond which even
perfection cannot go, and yet I have known, and doubtless you have heard
of, cases where inventors have claimed, and so-called engineers have
certified to, much higher results.
The first step in generating steam is in burning the fuel to the best
advantage. A pound of carbon will generate 14,500 British thermal units,
during combustion into carbonic dioxide, and this will be the same,
whatever the temperature or the rapidity at which the combustion may take
place. If possible, we might oxidize it at as slow a rate as that with which
iron rusts or wood rots in the open air, or we might burn it [Pg 94] with the
Page 128
rapidity of gunpowder, a ton in a second, yet the total heat generated would
be precisely the same. Again, we may keep the temperature down to the
lowest point at which combustion can take place, by bringing large bodies
of air in contact with it, or otherwise, or we may supply it with just the right
quantity of pure oxygen, and burn it at a temperature approaching that of
dissociation, and still the heat units given off will be neither more nor less.
It follows, therefore, that great latitude in the manner or rapidity of
combustion may be taken without affecting the quantity of heat generated.
But in practice it is found that other considerations limit this latitude, and
that there are certain conditions necessary in order to get the most available
heat from a pound of coal. There are three ways, and only three, in which
the heat developed by the combustion of coal in a steam boiler furnace may
be expended.
1st, and principally. It should be conveyed to the water in the boiler, and be
utilized in the production of steam. To be perfect, a boiler should so utilize
all the heat of combustion, but there are no perfect boilers.
2nd. A portion of the heat of combustion is conveyed up the chimney in the
waste gases. This is in proportion to the weight of the gases, and the
difference between their temperature and that of the air and coal before they
entered the fire.
3rd. Another portion is dissipated by radiation from the sides of the furnace.
In a stove the heat is all used in these latter two ways, either it goes off
through the chimney or is radiated into the surrounding space. It is one of
the principal problems of boiler engineering to render the amount of heat
thus lost as small as possible.
The loss from radiation is in proportion to the amount of surface, its nature,
its temperature, and the time it is exposed. This loss can be almost entirely
eliminated by thick walls and a smooth white or polished surface, but its
amount is ordinarily so small that these extraordinary precautions do not
pay in practice.
It is evident that the temperature of the escaping gases cannot be brought
below that of the absorbing surfaces, while it may be much greater even to
be precisely the same. Again, we may keep the temperature down to the
lowest point at which combustion can take place, by bringing large bodies
of air in contact with it, or otherwise, or we may supply it with just the right
quantity of pure oxygen, and burn it at a temperature approaching that of
dissociation, and still the heat units given off will be neither more nor less.
It follows, therefore, that great latitude in the manner or rapidity of
combustion may be taken without affecting the quantity of heat generated.
But in practice it is found that other considerations limit this latitude, and
that there are certain conditions necessary in order to get the most available
heat from a pound of coal. There are three ways, and only three, in which
the heat developed by the combustion of coal in a steam boiler furnace may
be expended.
1st, and principally. It should be conveyed to the water in the boiler, and be
utilized in the production of steam. To be perfect, a boiler should so utilize
all the heat of combustion, but there are no perfect boilers.
2nd. A portion of the heat of combustion is conveyed up the chimney in the
waste gases. This is in proportion to the weight of the gases, and the
difference between their temperature and that of the air and coal before they
entered the fire.
3rd. Another portion is dissipated by radiation from the sides of the furnace.
In a stove the heat is all used in these latter two ways, either it goes off
through the chimney or is radiated into the surrounding space. It is one of
the principal problems of boiler engineering to render the amount of heat
thus lost as small as possible.
The loss from radiation is in proportion to the amount of surface, its nature,
its temperature, and the time it is exposed. This loss can be almost entirely
eliminated by thick walls and a smooth white or polished surface, but its
amount is ordinarily so small that these extraordinary precautions do not
pay in practice.
It is evident that the temperature of the escaping gases cannot be brought
below that of the absorbing surfaces, while it may be much greater even to
Page 129
that of the fire. This is supposing that all of the escaping gases have passed
through the fire. In case air is allowed to leak into the flues, and mingle
with the gases after they have left the heating surfaces, the temperature may
be brought down to almost any point above that of the atmosphere, but
without any reduction in the amount of heat wasted. It is in this way that
those low chimney temperatures are sometimes attained which pass for
proof of economy with the unobserving. All surplus air admitted to the fire,
or to the gases before they leave the heating surfaces, increases the losses.
We are now prepared to see why and how the temperature and the rapidity
of combustion in the boiler furnace affect the economy, and that though the
amount of heat developed may be the same, the heat available for the
generation of steam may be much less with one rate or temperature of
combustion than another.
Assuming that there is no air passing up the chimney other than that which
has passed through the fire, the higher the temperature of the fire and the
lower that of the escaping gases the better the economy, for the losses by
the chimney gases will bear the same proportion to the heat generated by
the combustion as the temperature of those gases bears to the temperature
of the fire. That is to say, if the temperature of the fire is 2500 degrees and
that of the chimney gases 500 degrees above that of the atmosphere, the
loss by the chimney will be 500⁄2500 = 20 per cent. Therefore, as the escaping
gases cannot be brought below the temperature of the absorbing surface,
[Pg 95] which is practically a fixed quantity, the temperature of the fire must
be high in order to secure good economy.
The losses by radiation being practically proportioned to the time occupied,
the more coal burned in a given furnace in a given time, the less will be the
proportionate loss from that cause.
It therefore follows that we should burn our coal rapidly and at a high
temperature to secure the best available economy.
through the fire. In case air is allowed to leak into the flues, and mingle
with the gases after they have left the heating surfaces, the temperature may
be brought down to almost any point above that of the atmosphere, but
without any reduction in the amount of heat wasted. It is in this way that
those low chimney temperatures are sometimes attained which pass for
proof of economy with the unobserving. All surplus air admitted to the fire,
or to the gases before they leave the heating surfaces, increases the losses.
We are now prepared to see why and how the temperature and the rapidity
of combustion in the boiler furnace affect the economy, and that though the
amount of heat developed may be the same, the heat available for the
generation of steam may be much less with one rate or temperature of
combustion than another.
Assuming that there is no air passing up the chimney other than that which
has passed through the fire, the higher the temperature of the fire and the
lower that of the escaping gases the better the economy, for the losses by
the chimney gases will bear the same proportion to the heat generated by
the combustion as the temperature of those gases bears to the temperature
of the fire. That is to say, if the temperature of the fire is 2500 degrees and
that of the chimney gases 500 degrees above that of the atmosphere, the
loss by the chimney will be 500⁄2500 = 20 per cent. Therefore, as the escaping
gases cannot be brought below the temperature of the absorbing surface,
[Pg 95] which is practically a fixed quantity, the temperature of the fire must
be high in order to secure good economy.
The losses by radiation being practically proportioned to the time occupied,
the more coal burned in a given furnace in a given time, the less will be the
proportionate loss from that cause.
It therefore follows that we should burn our coal rapidly and at a high
temperature to secure the best available economy.
Page 130
Portion of 9880 Horse-power Installation of Babcock & Wilcox Boilers
and Superheaters, Equipped with Babcock & Wilcox Chain Grate
Stokers at the South Side Elevated Ry. Co., Chicago, Ill.
FOOTNOTES
[10] See Scientific American Supplement, 624, 625, December, 1887.
[11] 460 degrees below the zero of Fahrenheit. This is the nearest approximation
in whole degrees to the latest determinations of the absolute zero of temperature
and Superheaters, Equipped with Babcock & Wilcox Chain Grate
Stokers at the South Side Elevated Ry. Co., Chicago, Ill.
FOOTNOTES
[10] See Scientific American Supplement, 624, 625, December, 1887.
[11] 460 degrees below the zero of Fahrenheit. This is the nearest approximation
in whole degrees to the latest determinations of the absolute zero of temperature
Page 131
[Pg 96]
Page 132
PROPERTIES OF WATER
Pure water is a chemical compound of one volume of oxygen and two volumes of hydrogen, its chemical
symbol being H 2 O.
The weight of water depends upon its temperature. Its weight at four temperatures, much used in physical
calculations, is given in Table 10 .
TABLE 10 While authorities differ as to the weight of water, the
range of values given for 62 degrees Fahrenheit (the
WEIGHT OF WATER AT TEMPERATURES standard temperature ordinarily taken) being from
USED IN PHYSICAL CALCULATIONS 62.291 pounds to 62.360 pounds per cubic foot, the
Weight per Weight per value 62.355 is generally accepted as the most
Temperature Degrees accurate.
Cubic Foot Cubic Inch
Fahrenheit
Pounds Pounds
A United States standard gallon holds 231 cubic
At 32 degrees or freezing
point at sea level 62.418 0.03612 inches and weighs, at 62 degrees Fahrenheit,
approximately 8 1 ⁄ 3 pounds.
At 39.2 degrees or point of
maximum density 62.427 0.03613 A British Imperial gallon holds 277.42 cubic inches
At 62 degrees or standard and weighs, at 62 degrees Fahrenheit, 10 pounds.
temperature 62.355 0.03608
At 212 degrees or boiling The above are the true weights corrected for the effect
point at sea level 59.846 0.03469 of the buoyancy of the air, or the weight in vacuo . If
water is weighed in air in the ordinary way, there is a
correction of about one-eighth of one per cent which is usually negligible.
TABLE 11
VOLUME AND WEIGHT OF DISTILLED WATER AT VARIOUS TEMPERATURES [12]
Temper- Relative Weight Temper- Relative Weight Temper- Relative Weight Temper- Relative Weight
ature Volume per ature Volume per ature Volume per ature Volume per
Degrees Water Cubic Degrees Water Cubic Degrees Water Cubic Degrees Water Cubic
Fahren- at 39.2° Foot Fahren- at 39.2° Foot Fahren- at 39.2° Foot Fahren- at 39.2° Foot
heit = 1.000 Pounds heit = 1.000 Pounds heit = 1.000 Pounds heit = 1.000 Pounds
32 1.000176 62.42 160 1.02337 61.00 290 1.0830 57.65 430 1.197 52.2
39.2 1.000000 62.43 170 1.02682 60.80 300 1.0890 57.33 440 1.208 51.7
40 1.000004 62.43 180 1.03047 60.58 310 1.0953 57.00 450 1.220 51.2
50 1.00027 62.42 190 1.03431 60.36 320 1.1019 56.66 460 1.232 50.7
60 1.00096 62.37 200 1.03835 60.12 330 1.1088 56.30 470 1.244 50.2
70 1.00201 62.30 210 1.04256 59.88 340 1.1160 55.94 480 1.256 49.7
80 1.00338 62.22 212 1.04343 59.83 350 1.1235 55.57 490 1.269 49.2
90 1.00504 62.11 220 1.0469 59.63 360 1.1313 55.18 500 1.283 48.7
100 1.00698 62.00 230 1.0515 59.37 370 1.1396 54.78 510 1.297 48.1
110 1.00915 61.86 240 1.0562 59.11 380 1.1483 54.36 520 1.312 47.6
120 1.01157 61.71 250 1.0611 58.83 390 1.1573 53.94 530 1.329 47.0
130 1.01420 61.55 260 1.0662 58.55 400 1.167 53.5 540 1.35 46.3
140 1.01705 61.38 270 1.0715 58.26 410 1.177 53.0 550 1.37 45.6
150 1.02011 61.20 280 1.0771 57.96 420 1.187 52.6 560 1.39 44.9
Pure water is a chemical compound of one volume of oxygen and two volumes of hydrogen, its chemical
symbol being H 2 O.
The weight of water depends upon its temperature. Its weight at four temperatures, much used in physical
calculations, is given in Table 10 .
TABLE 10 While authorities differ as to the weight of water, the
range of values given for 62 degrees Fahrenheit (the
WEIGHT OF WATER AT TEMPERATURES standard temperature ordinarily taken) being from
USED IN PHYSICAL CALCULATIONS 62.291 pounds to 62.360 pounds per cubic foot, the
Weight per Weight per value 62.355 is generally accepted as the most
Temperature Degrees accurate.
Cubic Foot Cubic Inch
Fahrenheit
Pounds Pounds
A United States standard gallon holds 231 cubic
At 32 degrees or freezing
point at sea level 62.418 0.03612 inches and weighs, at 62 degrees Fahrenheit,
approximately 8 1 ⁄ 3 pounds.
At 39.2 degrees or point of
maximum density 62.427 0.03613 A British Imperial gallon holds 277.42 cubic inches
At 62 degrees or standard and weighs, at 62 degrees Fahrenheit, 10 pounds.
temperature 62.355 0.03608
At 212 degrees or boiling The above are the true weights corrected for the effect
point at sea level 59.846 0.03469 of the buoyancy of the air, or the weight in vacuo . If
water is weighed in air in the ordinary way, there is a
correction of about one-eighth of one per cent which is usually negligible.
TABLE 11
VOLUME AND WEIGHT OF DISTILLED WATER AT VARIOUS TEMPERATURES [12]
Temper- Relative Weight Temper- Relative Weight Temper- Relative Weight Temper- Relative Weight
ature Volume per ature Volume per ature Volume per ature Volume per
Degrees Water Cubic Degrees Water Cubic Degrees Water Cubic Degrees Water Cubic
Fahren- at 39.2° Foot Fahren- at 39.2° Foot Fahren- at 39.2° Foot Fahren- at 39.2° Foot
heit = 1.000 Pounds heit = 1.000 Pounds heit = 1.000 Pounds heit = 1.000 Pounds
32 1.000176 62.42 160 1.02337 61.00 290 1.0830 57.65 430 1.197 52.2
39.2 1.000000 62.43 170 1.02682 60.80 300 1.0890 57.33 440 1.208 51.7
40 1.000004 62.43 180 1.03047 60.58 310 1.0953 57.00 450 1.220 51.2
50 1.00027 62.42 190 1.03431 60.36 320 1.1019 56.66 460 1.232 50.7
60 1.00096 62.37 200 1.03835 60.12 330 1.1088 56.30 470 1.244 50.2
70 1.00201 62.30 210 1.04256 59.88 340 1.1160 55.94 480 1.256 49.7
80 1.00338 62.22 212 1.04343 59.83 350 1.1235 55.57 490 1.269 49.2
90 1.00504 62.11 220 1.0469 59.63 360 1.1313 55.18 500 1.283 48.7
100 1.00698 62.00 230 1.0515 59.37 370 1.1396 54.78 510 1.297 48.1
110 1.00915 61.86 240 1.0562 59.11 380 1.1483 54.36 520 1.312 47.6
120 1.01157 61.71 250 1.0611 58.83 390 1.1573 53.94 530 1.329 47.0
130 1.01420 61.55 260 1.0662 58.55 400 1.167 53.5 540 1.35 46.3
140 1.01705 61.38 270 1.0715 58.26 410 1.177 53.0 550 1.37 45.6
150 1.02011 61.20 280 1.0771 57.96 420 1.187 52.6 560 1.39 44.9
Page 133
[Pg 97]
Water is but slightly compressible and for all practical purposes may be considered non-compressible. The
coefficient of compressibility ranges from 0.000040 to 0.000051 per atmosphere at ordinary temperatures, this
coefficient decreasing as the temperature increases.
Table 11 gives the weight in vacuo and the relative volume of a cubic foot of distilled water at various
temperatures.
The weight of water at the standard temperature being taken as 62.355 pounds per cubic foot, the pressure
exerted by the column of water of any stated height, and conversely the height of any column required to
produce a stated pressure, may be computed as follows:
The pressure in pounds per square foot = 62.355 × height of column in feet.
The pressure in pounds per square inch = 0.433 × height of column in feet.
Height of column in feet = pressure in pounds per square foot ÷ 62.355.
Height of column in feet = pressure in pounds per square inch ÷ 0.433.
Height of column in inches = pressure in pounds per square inch × 27.71.
Height of column in inches = pressure in ounces per square inch × 1.73.
By a change in the weights given above, the pressure exerted and height of column may be computed for
temperatures other than 62 degrees.
A pressure of one pound per square inch is exerted by a column of water 2.3093 feet or 27.71 inches high at 62
degrees Fahrenheit.
Water in its natural state is never found absolutely pure. In solvent power water has a greater range than any
other liquid. For common salt, this is approximately a constant at all temperatures, while with such impurities
as magnesium and sodium sulphates, this solvent power increases with an increase in temperature.
TABLE 12
BOILING POINT OF WATER AT VARIOUS ALTITUDES
Boiling Altitude Atmospheric Barometer Boiling Altitude Atmospheric Barometer
Point Above Pressure Reduced to Point Above Pressure Reduced to
Degrees Sea Level Pounds per 32 Degrees Degrees Sea Level Pounds per 32 Degrees
Fahrenheit Feet Square Inch Inches Fahrenheit Feet Square Inch Inches
184 15221 8.20 16.70 199 6843 11.29 22.99
185 14649 8.38 17.06 200 6304 11.52 23.47
186 14075 8.57 17.45 201 5764 11.76 23.95
187 13498 8.76 17.83 202 5225 12.01 24.45
188 12934 8.95 18.22 203 4697 12.26 24.96
189 12367 9.14 18.61 204 4169 12.51 25.48
190 11799 9.34 19.02 205 3642 12.77 26.00
191 11243 9.54 19.43 206 3115 13.03 26.53
192 10685 9.74 19.85 207 2589 13.30 27.08
193 10127 9.95 20.27 208 2063 13.57 27.63
194 9579 10.17 20.71 209 1539 13.85 28.19
195 9031 10.39 21.15 210 1025 14.13 28.76
Water is but slightly compressible and for all practical purposes may be considered non-compressible. The
coefficient of compressibility ranges from 0.000040 to 0.000051 per atmosphere at ordinary temperatures, this
coefficient decreasing as the temperature increases.
Table 11 gives the weight in vacuo and the relative volume of a cubic foot of distilled water at various
temperatures.
The weight of water at the standard temperature being taken as 62.355 pounds per cubic foot, the pressure
exerted by the column of water of any stated height, and conversely the height of any column required to
produce a stated pressure, may be computed as follows:
The pressure in pounds per square foot = 62.355 × height of column in feet.
The pressure in pounds per square inch = 0.433 × height of column in feet.
Height of column in feet = pressure in pounds per square foot ÷ 62.355.
Height of column in feet = pressure in pounds per square inch ÷ 0.433.
Height of column in inches = pressure in pounds per square inch × 27.71.
Height of column in inches = pressure in ounces per square inch × 1.73.
By a change in the weights given above, the pressure exerted and height of column may be computed for
temperatures other than 62 degrees.
A pressure of one pound per square inch is exerted by a column of water 2.3093 feet or 27.71 inches high at 62
degrees Fahrenheit.
Water in its natural state is never found absolutely pure. In solvent power water has a greater range than any
other liquid. For common salt, this is approximately a constant at all temperatures, while with such impurities
as magnesium and sodium sulphates, this solvent power increases with an increase in temperature.
TABLE 12
BOILING POINT OF WATER AT VARIOUS ALTITUDES
Boiling Altitude Atmospheric Barometer Boiling Altitude Atmospheric Barometer
Point Above Pressure Reduced to Point Above Pressure Reduced to
Degrees Sea Level Pounds per 32 Degrees Degrees Sea Level Pounds per 32 Degrees
Fahrenheit Feet Square Inch Inches Fahrenheit Feet Square Inch Inches
184 15221 8.20 16.70 199 6843 11.29 22.99
185 14649 8.38 17.06 200 6304 11.52 23.47
186 14075 8.57 17.45 201 5764 11.76 23.95
187 13498 8.76 17.83 202 5225 12.01 24.45
188 12934 8.95 18.22 203 4697 12.26 24.96
189 12367 9.14 18.61 204 4169 12.51 25.48
190 11799 9.34 19.02 205 3642 12.77 26.00
191 11243 9.54 19.43 206 3115 13.03 26.53
192 10685 9.74 19.85 207 2589 13.30 27.08
193 10127 9.95 20.27 208 2063 13.57 27.63
194 9579 10.17 20.71 209 1539 13.85 28.19
195 9031 10.39 21.15 210 1025 14.13 28.76
Page 134
196 8481 10.61 21.60 211 512 14.41 29.33
197 7932 10.83 22.05 212 Sea Level 14.70 29.92
198 7381 11.06 22.52
Sea water contains on an average approximately 3.125 per cent of its weight of solid matter or a thirty-second
part of the weight of the water and salt held in solution. [Pg 98]
[Pg 99] The approximate composition of this solid matter will be: sodium chloride 76 per cent, magnesium
chloride 10 per cent, magnesium sulphate 6 per cent, calcium sulphate 5 per cent, calcium carbonate 0.5 per
cent, other substances 2.5 per cent.
7200 Horse-power Installation of Babcock & Wilcox Boilers and Superheaters at the Capital Traction
Co., Washington, D. C.
The boiling point of water decreases as the altitude above sea level increases. Table 12 gives the variation in
the boiling point with the altitude.
Water has a greater specific heat or heat-absorbing capacity than any other known substance (bromine and
hydrogen excepted) and its specific heat is the basis for measurement of the capacity of heat absorption of all
other substances. From the definition, the specific heat of water is the number of British thermal units required
to raise one pound of water one degree. This specific heat varies with the temperature of the water. The
generally accepted values are given in Table 13 , which indicates the values as determined by Messrs. Marks
and Davis and Mr. Peabody.
TABLE 13
SPECIFIC HEAT OF WATER AT VARIOUS TEMPERATURES
MARKS AND DAVIS PEABODY
From Values of Barnes and Dieterici From Values of Barnes and Regnault
Temperature Temperature Temperature Temperature
Specific Specific Specific Specific
Degrees Degrees Degrees Degrees Degrees Degrees
Heat Heat Heat Heat
Fahrenheit Fahrenheit Centigrade Fahrenheit Centigrade Fahrenheit
30 1.0098 130 0.9979 0 32 1.0094 50 122 0.9980
197 7932 10.83 22.05 212 Sea Level 14.70 29.92
198 7381 11.06 22.52
Sea water contains on an average approximately 3.125 per cent of its weight of solid matter or a thirty-second
part of the weight of the water and salt held in solution. [Pg 98]
[Pg 99] The approximate composition of this solid matter will be: sodium chloride 76 per cent, magnesium
chloride 10 per cent, magnesium sulphate 6 per cent, calcium sulphate 5 per cent, calcium carbonate 0.5 per
cent, other substances 2.5 per cent.
7200 Horse-power Installation of Babcock & Wilcox Boilers and Superheaters at the Capital Traction
Co., Washington, D. C.
The boiling point of water decreases as the altitude above sea level increases. Table 12 gives the variation in
the boiling point with the altitude.
Water has a greater specific heat or heat-absorbing capacity than any other known substance (bromine and
hydrogen excepted) and its specific heat is the basis for measurement of the capacity of heat absorption of all
other substances. From the definition, the specific heat of water is the number of British thermal units required
to raise one pound of water one degree. This specific heat varies with the temperature of the water. The
generally accepted values are given in Table 13 , which indicates the values as determined by Messrs. Marks
and Davis and Mr. Peabody.
TABLE 13
SPECIFIC HEAT OF WATER AT VARIOUS TEMPERATURES
MARKS AND DAVIS PEABODY
From Values of Barnes and Dieterici From Values of Barnes and Regnault
Temperature Temperature Temperature Temperature
Specific Specific Specific Specific
Degrees Degrees Degrees Degrees Degrees Degrees
Heat Heat Heat Heat
Fahrenheit Fahrenheit Centigrade Fahrenheit Centigrade Fahrenheit
30 1.0098 130 0.9979 0 32 1.0094 50 122 0.9980
Page 135
40 1.0045 140 0.9986 5 41 1.0053 55 131 0.9985
50 1.0012 150 0.9994 10 50 1.0023 60 140 0.9994
55 1.0000 160 1.0002 15 59 1.0003 65 149 1.0004
60 0.9990 170 1.0010 16.11 61 1.0000 70 158 1.0015
70 0.9977 180 1.0019 20 68 0.9990 75 167 1.0028
80 0.9970 190 1.0029 25 77 0.9981 80 176 1.0042
90 0.9967 200 1.0039 30 86 0.9976 85 185 1.0056
100 0.9967 210 1.0052 35 95 0.9974 90 194 1.0071
110 0.9970 220 1.007 40 104 0.9974 95 203 1.0086
120 0.9974 230 1.009 45 113 0.9976 100 212 1.0101
In consequence of this variation in specific heat, the variation in the heat of the liquid of the water at different
temperatures is not a constant. Table 22 [13] gives the heat of the liquid in a pound of water at temperatures
ranging from 32 to 340 degrees Fahrenheit.
The specific heat of ice at 32 degrees is 0.463. The specific heat of saturated steam (ice and saturated steam
representing the other forms in which water may exist), is something that is difficult to define in any way
which will not be misleading. When no liquid is present the specific heat of saturated steam is negative. [14]
The use of the value of the specific heat of steam is practically limited to instances where superheat is present,
and the specific heat of superheated steam is covered later in the book.
FOOTNOTES
[12] Marks and Davis
[13] See page 120 .
[14] See Trans., A. S. M. E., Vol. XIV., Page 79.
50 1.0012 150 0.9994 10 50 1.0023 60 140 0.9994
55 1.0000 160 1.0002 15 59 1.0003 65 149 1.0004
60 0.9990 170 1.0010 16.11 61 1.0000 70 158 1.0015
70 0.9977 180 1.0019 20 68 0.9990 75 167 1.0028
80 0.9970 190 1.0029 25 77 0.9981 80 176 1.0042
90 0.9967 200 1.0039 30 86 0.9976 85 185 1.0056
100 0.9967 210 1.0052 35 95 0.9974 90 194 1.0071
110 0.9970 220 1.007 40 104 0.9974 95 203 1.0086
120 0.9974 230 1.009 45 113 0.9976 100 212 1.0101
In consequence of this variation in specific heat, the variation in the heat of the liquid of the water at different
temperatures is not a constant. Table 22 [13] gives the heat of the liquid in a pound of water at temperatures
ranging from 32 to 340 degrees Fahrenheit.
The specific heat of ice at 32 degrees is 0.463. The specific heat of saturated steam (ice and saturated steam
representing the other forms in which water may exist), is something that is difficult to define in any way
which will not be misleading. When no liquid is present the specific heat of saturated steam is negative. [14]
The use of the value of the specific heat of steam is practically limited to instances where superheat is present,
and the specific heat of superheated steam is covered later in the book.
FOOTNOTES
[12] Marks and Davis
[13] See page 120 .
[14] See Trans., A. S. M. E., Vol. XIV., Page 79.
Page 136
[Pg 100]
Page 137
BOILER FEED WATER
All natural waters contain some impurities which, when introduced into a
boiler, may appear as solids. In view of the apparent present-day tendency
toward large size boiler units and high overloads, the importance of the use
of pure water for boiler feed purposes cannot be over-estimated.
Ordinarily, when water of sufficient purity for such use is not at hand, the
supply available may be rendered suitable by some process of treatment.
Against the cost of such treatment, there are many factors to be considered.
With water in which there is a marked tendency toward scale formation, the
interest and depreciation on the added boiler units necessary to allow for the
systematic cleaning of certain units must be taken into consideration. Again
there is a considerable loss in taking boilers off for cleaning and replacing
them on the line. On the other hand, the decrease in capacity and efficiency
accompanying an increased incrustation of boilers in use has been too
generally discussed to need repetition here. Many experiments have been
made and actual figures reported as to this decrease, but in general, such
figures apply only to the particular set of conditions found in the plant where
the boiler in question was tested. So many factors enter into the effect of
scale on capacity and economy that it is impossible to give any accurate
figures on such decrease that will serve all cases, but that it is large has been
thoroughly proven.
While it is almost invariably true that practically any cost of treatment will
pay a return on the investment of the apparatus, the fact must not be
overlooked that there are certain waters which should never be used for
boiler feed purposes and which no treatment can render suitable for such
purpose. In such cases, the only remedy is the securing of other feed supply
or the employment of evaporators for distilling the feed water as in marine
service.
TABLE 14
APPROXIMATE CLASSIFICATION OF IMPURITIES FOUND IN FEED
All natural waters contain some impurities which, when introduced into a
boiler, may appear as solids. In view of the apparent present-day tendency
toward large size boiler units and high overloads, the importance of the use
of pure water for boiler feed purposes cannot be over-estimated.
Ordinarily, when water of sufficient purity for such use is not at hand, the
supply available may be rendered suitable by some process of treatment.
Against the cost of such treatment, there are many factors to be considered.
With water in which there is a marked tendency toward scale formation, the
interest and depreciation on the added boiler units necessary to allow for the
systematic cleaning of certain units must be taken into consideration. Again
there is a considerable loss in taking boilers off for cleaning and replacing
them on the line. On the other hand, the decrease in capacity and efficiency
accompanying an increased incrustation of boilers in use has been too
generally discussed to need repetition here. Many experiments have been
made and actual figures reported as to this decrease, but in general, such
figures apply only to the particular set of conditions found in the plant where
the boiler in question was tested. So many factors enter into the effect of
scale on capacity and economy that it is impossible to give any accurate
figures on such decrease that will serve all cases, but that it is large has been
thoroughly proven.
While it is almost invariably true that practically any cost of treatment will
pay a return on the investment of the apparatus, the fact must not be
overlooked that there are certain waters which should never be used for
boiler feed purposes and which no treatment can render suitable for such
purpose. In such cases, the only remedy is the securing of other feed supply
or the employment of evaporators for distilling the feed water as in marine
service.
TABLE 14
APPROXIMATE CLASSIFICATION OF IMPURITIES FOUND IN FEED
Page 138
WATERS
THEIR EFFECT AND ORDINARY METHODS OF RELIEF
Difficulty Resulting Nature of Ordinary Method of
from Presence of Difficulty Overcoming or Relieving
Sediment, Mud, etc. Incrustation Settling tanks, filtration, blowing
down.
Readily Soluble Salts Incrustation Blowing down.
Bicarbonates of Lime, Incrustation Heating feed.
Magnesia, etc. Treatment by addition of lime or
of lime and soda.
Barium carbonate.
Sulphate of Lime Incrustation Treatment by addition of soda.
Barium carbonate.
Chloride and Sulphate of Corrosion Treatment by addition of
Magnesium carbonate of soda.
Acid Corrosion Alkali.
Dissolved Carbonic Acid Corrosion Heating feed. Keeping air from
and Oxygen feed.
Addition of caustic soda or
slacked lime.
Grease Corrosion Filter. Iron alum as coagulent.
Neutralization by carbonate of
soda.
Use of best hydrocarbon oils.
Organic Matter Corrosion Filter. Use of coagulent.
Organic Matter (Sewage) Priming Settling tanks. Filter in connection
with coagulent.
Carbonate of Soda in large Priming Barium carbonate. New feed
quantities supply.
If from treatment, change.
[Pg 101]
It is evident that the whole subject of boiler feed waters and their treatment
is one for the chemist rather than for the engineer. A brief outline of the
difficulties that may be experienced from the use of poor feed water and a
THEIR EFFECT AND ORDINARY METHODS OF RELIEF
Difficulty Resulting Nature of Ordinary Method of
from Presence of Difficulty Overcoming or Relieving
Sediment, Mud, etc. Incrustation Settling tanks, filtration, blowing
down.
Readily Soluble Salts Incrustation Blowing down.
Bicarbonates of Lime, Incrustation Heating feed.
Magnesia, etc. Treatment by addition of lime or
of lime and soda.
Barium carbonate.
Sulphate of Lime Incrustation Treatment by addition of soda.
Barium carbonate.
Chloride and Sulphate of Corrosion Treatment by addition of
Magnesium carbonate of soda.
Acid Corrosion Alkali.
Dissolved Carbonic Acid Corrosion Heating feed. Keeping air from
and Oxygen feed.
Addition of caustic soda or
slacked lime.
Grease Corrosion Filter. Iron alum as coagulent.
Neutralization by carbonate of
soda.
Use of best hydrocarbon oils.
Organic Matter Corrosion Filter. Use of coagulent.
Organic Matter (Sewage) Priming Settling tanks. Filter in connection
with coagulent.
Carbonate of Soda in large Priming Barium carbonate. New feed
quantities supply.
If from treatment, change.
[Pg 101]
It is evident that the whole subject of boiler feed waters and their treatment
is one for the chemist rather than for the engineer. A brief outline of the
difficulties that may be experienced from the use of poor feed water and a
Page 139
suggestion as to a method of overcoming certain of these difficulties is all
that will be attempted here. Such a brief outline of the subject, however, will
indicate the necessity for a chemical analysis of any water before a treatment
is tried and the necessity of adapting the treatment in each case to the nature
of the difficulties that may be experienced.
Table 14 gives a list of impurities which may be found in boiler feed water,
grouped according to their effect on boiler operation and giving the
customary method used for overcoming difficulty to which they lead.
Scale—Scale is formed on boiler heating surfaces by the depositing of
impurities in the feed water in the form of a more or less hard adherent crust.
Such deposits are due to the fact that water loses its soluble power at high
temperatures or because the concentration becomes so high, due to
evaporation, that the impurities crystallize and adhere to the boiler surfaces.
The opportunity for formation of scale in a boiler will be apparent when it is
realized that during a month’s operation of a 100 horse-power boiler, 300
pounds of solid matter may be deposited from water containing only 7 grains
per gallon, while some spring and well waters contain sufficient to cause a
deposit of as high as 2000 pounds.
TABLE 15 The salts
usually
SOLUBILITY OF MINERAL SALTS IN WATER responsibl
(SPARKS) e for such
IN GRAINS PER U. S. GALLON (58,381 GRAINS), incrustatio
EXCEPT AS NOTED n are the
Temperature Degrees Fahrenheit 60 Degrees 212 Degrees carbonates
and
Calcium Carbonate 2.5 1.5
sulphates
Calcium Sulphate 140.0 125.0
of lime
Magnesium Carbonate 1.0 1.8 and
Magnesium Sulphate 3.0 pounds 12.0 pounds magnesia,
Sodium Chloride 3.5 pounds 4.0 pounds and boiler
Sodium Sulphate 1.1 pounds 5.0 pounds feed
treatment
in general deals with the getting rid of these salts more or less completely.
that will be attempted here. Such a brief outline of the subject, however, will
indicate the necessity for a chemical analysis of any water before a treatment
is tried and the necessity of adapting the treatment in each case to the nature
of the difficulties that may be experienced.
Table 14 gives a list of impurities which may be found in boiler feed water,
grouped according to their effect on boiler operation and giving the
customary method used for overcoming difficulty to which they lead.
Scale—Scale is formed on boiler heating surfaces by the depositing of
impurities in the feed water in the form of a more or less hard adherent crust.
Such deposits are due to the fact that water loses its soluble power at high
temperatures or because the concentration becomes so high, due to
evaporation, that the impurities crystallize and adhere to the boiler surfaces.
The opportunity for formation of scale in a boiler will be apparent when it is
realized that during a month’s operation of a 100 horse-power boiler, 300
pounds of solid matter may be deposited from water containing only 7 grains
per gallon, while some spring and well waters contain sufficient to cause a
deposit of as high as 2000 pounds.
TABLE 15 The salts
usually
SOLUBILITY OF MINERAL SALTS IN WATER responsibl
(SPARKS) e for such
IN GRAINS PER U. S. GALLON (58,381 GRAINS), incrustatio
EXCEPT AS NOTED n are the
Temperature Degrees Fahrenheit 60 Degrees 212 Degrees carbonates
and
Calcium Carbonate 2.5 1.5
sulphates
Calcium Sulphate 140.0 125.0
of lime
Magnesium Carbonate 1.0 1.8 and
Magnesium Sulphate 3.0 pounds 12.0 pounds magnesia,
Sodium Chloride 3.5 pounds 4.0 pounds and boiler
Sodium Sulphate 1.1 pounds 5.0 pounds feed
treatment
in general deals with the getting rid of these salts more or less completely.
Page 140
Table 15 gives the solubility of these mineral salts in water at various
temperatures in grains per U. S. gallon (58,381 grains). It will be seen from
this table that the carbonates of lime and magnesium are not soluble above
212 degrees, and calcium sulphate while somewhat insoluble above 212
degrees becomes more greatly so as the temperature increases.
Scale is also formed by the settling of mud and sediment carried in
suspension in water. This may bake or be cemented to a hard scale when
mixed with other scale-forming ingredients.
CALCIUM SULPHATE AT TEMPERATURE ABOVE Corrosio
212 DEGREES (CHRISTIE) n—
Temperature degrees Fahrenheit 284 329 347-365 464 482 Corrosion
, or a
Corresponding gauge pressure 38 87 115-149 469 561
chemical
Grains per gallon 45.5 32.7 15.7 10.5 9.3
action
leading to
the actual destruction of the boiler metal, is due to the solvent or oxidizing
properties of the feed water. It [Pg 102] results from the presence of acid,
either free or developed[15] in the feed, the admixture of air with the feed
water, or as a result of a galvanic action. In boilers it takes several forms:
1st. Pitting, which consists of isolated spots of active corrosion which does
not attack the boiler as a whole.
2nd. General corrosion, produced by naturally acid waters and where the
amount is so even and continuous that no accurate estimate of the metal
eaten away may be made.
3rd. Grooving, which, while largely a mechanical action which may occur in
neutral waters, is intensified by acidity.
Foaming—This phenomenon, which ordinarily occurs with waters
contaminated with sewage or organic growths, is due to the fact that the
suspended particles collect on the surface of the water in the boiler and
render difficult the liberation of steam bubbles arising to that surface. It
sometimes occurs with water containing carbonates in solution in which a
light flocculent precipitate will be formed on the surface of the water. Again,
temperatures in grains per U. S. gallon (58,381 grains). It will be seen from
this table that the carbonates of lime and magnesium are not soluble above
212 degrees, and calcium sulphate while somewhat insoluble above 212
degrees becomes more greatly so as the temperature increases.
Scale is also formed by the settling of mud and sediment carried in
suspension in water. This may bake or be cemented to a hard scale when
mixed with other scale-forming ingredients.
CALCIUM SULPHATE AT TEMPERATURE ABOVE Corrosio
212 DEGREES (CHRISTIE) n—
Temperature degrees Fahrenheit 284 329 347-365 464 482 Corrosion
, or a
Corresponding gauge pressure 38 87 115-149 469 561
chemical
Grains per gallon 45.5 32.7 15.7 10.5 9.3
action
leading to
the actual destruction of the boiler metal, is due to the solvent or oxidizing
properties of the feed water. It [Pg 102] results from the presence of acid,
either free or developed[15] in the feed, the admixture of air with the feed
water, or as a result of a galvanic action. In boilers it takes several forms:
1st. Pitting, which consists of isolated spots of active corrosion which does
not attack the boiler as a whole.
2nd. General corrosion, produced by naturally acid waters and where the
amount is so even and continuous that no accurate estimate of the metal
eaten away may be made.
3rd. Grooving, which, while largely a mechanical action which may occur in
neutral waters, is intensified by acidity.
Foaming—This phenomenon, which ordinarily occurs with waters
contaminated with sewage or organic growths, is due to the fact that the
suspended particles collect on the surface of the water in the boiler and
render difficult the liberation of steam bubbles arising to that surface. It
sometimes occurs with water containing carbonates in solution in which a
light flocculent precipitate will be formed on the surface of the water. Again,
Page 141
it is the result of an excess of sodium carbonate used in treatment for some
other difficulty where animal or vegetable oil finds its way into the boiler.
Priming—Priming, or the passing off of steam from a boiler in belches, is
caused by the concentration of sodium carbonate, sodium sulphate or sodium
chloride in solution. Sodium sulphate is found in many southern waters and
also where calcium or magnesium sulphate is precipitated with soda ash.
Treatment of Feed Water—For scale formation. The treatment of feed
water, carrying scale-forming ingredients, is along two main lines: 1st, by
chemical means by which such impurities as are carried by the water are
caused to precipitate; and 2nd, by the means of heat, which results in the
reduction of the power of water to hold certain salts in solution. The latter
method alone is sufficient in the case of certain temporarily hard waters, but
the heat treatment, in general, is used in connection with a chemical
treatment to assist the latter.
Before going further into detail as to the treatment of water, it may be well to
define certain terms used.
Hardness, which is the most widely known evidence of the presence in water
of scale-forming matter, is that quality, the variation of which makes it more
difficult to obtain a lather or suds from soap in one water than in another.
This action is made use of in the soap test for hardness described later.
Hardness is ordinarily classed as either temporary or permanent.
Temporarily hard waters are those containing carbonates of lime and
magnesium, which may be precipitated by boiling at 212 degrees and which,
if they contain no other scale-forming ingredients, become “soft” under such
treatment. Permanently hard waters are those containing mainly calcium
sulphate, which is only precipitated at the high temperatures found in the
boiler itself, 300 degrees Fahrenheit or more. The scale of hardness is an
arbitrary one, based on the number of grains of solids per gallon and waters
may be classed on such a basis as follows: 1-10 grain per gallon, soft water;
10-20 grain per gallon, moderately hard water; above 25 grains per gallon,
very hard water.
[Pg 103]
other difficulty where animal or vegetable oil finds its way into the boiler.
Priming—Priming, or the passing off of steam from a boiler in belches, is
caused by the concentration of sodium carbonate, sodium sulphate or sodium
chloride in solution. Sodium sulphate is found in many southern waters and
also where calcium or magnesium sulphate is precipitated with soda ash.
Treatment of Feed Water—For scale formation. The treatment of feed
water, carrying scale-forming ingredients, is along two main lines: 1st, by
chemical means by which such impurities as are carried by the water are
caused to precipitate; and 2nd, by the means of heat, which results in the
reduction of the power of water to hold certain salts in solution. The latter
method alone is sufficient in the case of certain temporarily hard waters, but
the heat treatment, in general, is used in connection with a chemical
treatment to assist the latter.
Before going further into detail as to the treatment of water, it may be well to
define certain terms used.
Hardness, which is the most widely known evidence of the presence in water
of scale-forming matter, is that quality, the variation of which makes it more
difficult to obtain a lather or suds from soap in one water than in another.
This action is made use of in the soap test for hardness described later.
Hardness is ordinarily classed as either temporary or permanent.
Temporarily hard waters are those containing carbonates of lime and
magnesium, which may be precipitated by boiling at 212 degrees and which,
if they contain no other scale-forming ingredients, become “soft” under such
treatment. Permanently hard waters are those containing mainly calcium
sulphate, which is only precipitated at the high temperatures found in the
boiler itself, 300 degrees Fahrenheit or more. The scale of hardness is an
arbitrary one, based on the number of grains of solids per gallon and waters
may be classed on such a basis as follows: 1-10 grain per gallon, soft water;
10-20 grain per gallon, moderately hard water; above 25 grains per gallon,
very hard water.
[Pg 103]
Page 142
Alkalinity is a general term used for waters containing compounds with the
power of neutralizing acids.
Causticity, as used in water treatment, is a term coined by A. McGill,
indicating the presence of an excess of lime added during treatment. Though
such presence would also indicate alkalinity, the term is arbitrarily used to
apply to those hydrates whose presence is indicated by phenolphthalein.
Of the chemical methods of water treatment, there are three general
processes:
1st. Lime Process. The lime process is used for waters containing
bicarbonates of lime and magnesia. Slacked lime in solution, as lime water,
is the reagent used. This combines with the carbonic acid which is present,
either free or as carbonates, to form an insoluble monocarbonate of lime.
The soluble bicarbonates of lime and magnesia, losing their carbonic acid,
thereby become insoluble and precipitate.
2nd. Soda Process. The soda process is used for waters containing sulphates
of lime and magnesia. Carbonate of soda and hydrate of soda (caustic soda)
are used either alone or together as the reagents. Carbonate of soda, added to
water containing little or no carbonic acid or bicarbonates, decomposes the
sulphates to form insoluble carbonate of lime or magnesia which precipitate,
the neutral soda remaining in solution. If free carbonic acid or bicarbonates
are present, bicarbonate of lime is formed and remains in solution, though
under the action of heat, the carbon dioxide will be driven off and insoluble
monocarbonates will be formed. Caustic soda used in this process causes a
more energetic action, it being presumed that the caustic soda absorbs the
carbonic acid, becomes carbonate of soda and acts as above.
3rd. Lime and Soda Process. This process, which is the combination of the
first two, is by far the most generally used in water purification. Such a
method is used where sulphates of lime and magnesia are contained in the
water, together with such quantity of carbonic acid or bicarbonates as to
impair the action of the soda. Sufficient soda is used to break down the
sulphates of lime and magnesia and as much lime added as is required to
absorb the carbonic acid not taken up in the soda reaction.
power of neutralizing acids.
Causticity, as used in water treatment, is a term coined by A. McGill,
indicating the presence of an excess of lime added during treatment. Though
such presence would also indicate alkalinity, the term is arbitrarily used to
apply to those hydrates whose presence is indicated by phenolphthalein.
Of the chemical methods of water treatment, there are three general
processes:
1st. Lime Process. The lime process is used for waters containing
bicarbonates of lime and magnesia. Slacked lime in solution, as lime water,
is the reagent used. This combines with the carbonic acid which is present,
either free or as carbonates, to form an insoluble monocarbonate of lime.
The soluble bicarbonates of lime and magnesia, losing their carbonic acid,
thereby become insoluble and precipitate.
2nd. Soda Process. The soda process is used for waters containing sulphates
of lime and magnesia. Carbonate of soda and hydrate of soda (caustic soda)
are used either alone or together as the reagents. Carbonate of soda, added to
water containing little or no carbonic acid or bicarbonates, decomposes the
sulphates to form insoluble carbonate of lime or magnesia which precipitate,
the neutral soda remaining in solution. If free carbonic acid or bicarbonates
are present, bicarbonate of lime is formed and remains in solution, though
under the action of heat, the carbon dioxide will be driven off and insoluble
monocarbonates will be formed. Caustic soda used in this process causes a
more energetic action, it being presumed that the caustic soda absorbs the
carbonic acid, becomes carbonate of soda and acts as above.
3rd. Lime and Soda Process. This process, which is the combination of the
first two, is by far the most generally used in water purification. Such a
method is used where sulphates of lime and magnesia are contained in the
water, together with such quantity of carbonic acid or bicarbonates as to
impair the action of the soda. Sufficient soda is used to break down the
sulphates of lime and magnesia and as much lime added as is required to
absorb the carbonic acid not taken up in the soda reaction.
Page 143
All of the apparatus for effecting such treatment of feed waters is
approximately the same in its chemical action, the numerous systems
differing in the methods of introduction and handling of the reagents.
The methods of testing water treated by an apparatus of this description
follow.
When properly treated, alkalinity, hardness and causticity should be in the
approximate relation of 6, 5 and 4. When too much lime is used in the
treatment, the causticity in the purified water, as indicated by the acid test,
will be nearly equal to the alkalinity. If too little lime is used, the causticity
will fall to approximately half the alkalinity. The hardness should not be in
excess of two points less than the alkalinity. Where too great a quantity of
soda is used, the hardness is lowered and the alkalinity raised. If too little
soda, the hardness is raised and the alkalinity lowered.
Alkalinity and causticity are tested with a standard solution of sulphuric
acid. A standard soap solution is used for testing for hardness and a silver
nitrate solution may also be used for determining whether an excess of lime
has been used in the treatment.
Alkalinity: To 50 cubic centimeters of treated water, to which there has been
added sufficient methylorange to color it, add the acid solution, drop by
drop, until the mixture is on the point of turning red. As the acid solution is
first added, the red color, which shows quickly, disappears on shaking the
mixture, and this color [Pg 104]
[Pg 105] disappears more slowly as the critical point is approached. One-tenth
cubic centimeter of the standard acid solution corresponds to one degree of
alkalinity.
approximately the same in its chemical action, the numerous systems
differing in the methods of introduction and handling of the reagents.
The methods of testing water treated by an apparatus of this description
follow.
When properly treated, alkalinity, hardness and causticity should be in the
approximate relation of 6, 5 and 4. When too much lime is used in the
treatment, the causticity in the purified water, as indicated by the acid test,
will be nearly equal to the alkalinity. If too little lime is used, the causticity
will fall to approximately half the alkalinity. The hardness should not be in
excess of two points less than the alkalinity. Where too great a quantity of
soda is used, the hardness is lowered and the alkalinity raised. If too little
soda, the hardness is raised and the alkalinity lowered.
Alkalinity and causticity are tested with a standard solution of sulphuric
acid. A standard soap solution is used for testing for hardness and a silver
nitrate solution may also be used for determining whether an excess of lime
has been used in the treatment.
Alkalinity: To 50 cubic centimeters of treated water, to which there has been
added sufficient methylorange to color it, add the acid solution, drop by
drop, until the mixture is on the point of turning red. As the acid solution is
first added, the red color, which shows quickly, disappears on shaking the
mixture, and this color [Pg 104]
[Pg 105] disappears more slowly as the critical point is approached. One-tenth
cubic centimeter of the standard acid solution corresponds to one degree of
alkalinity.
Page 144
2640 Horse-power Installation of Babcock & Wilcox Boilers at the
Botany Worsted Mills, Passaic, N. J.
Causticity: To 50 cubic centimeters of treated water, to which there has been
added one drop of phenolphthalein dissolved in alcohol to give the water a
pinkish color, add the acid solution, drop by drop, shaking after each
addition, until the color entirely disappears. One-tenth cubic centimeter of
acid solution corresponds to one degree of causticity.
The alkalinity may be determined from the same sample tested for causticity
by the coloring with methylorange and adding the acid until the sample is on
the point of turning red. The total acid added in determining both causticity
and alkalinity in this case is the measure of the alkalinity.
Hardness: 100 cubic centimeters of the treated water is used for this test, one
cubic centimeter of the soap solution corresponding to one degree of
hardness. The soap solution is added a very little at a time and the whole
violently shaken. Enough of the solution must be added to make a permanent
lather or foam, that is, the soap bubbles must not disappear after the shaking
is stopped.
Botany Worsted Mills, Passaic, N. J.
Causticity: To 50 cubic centimeters of treated water, to which there has been
added one drop of phenolphthalein dissolved in alcohol to give the water a
pinkish color, add the acid solution, drop by drop, shaking after each
addition, until the color entirely disappears. One-tenth cubic centimeter of
acid solution corresponds to one degree of causticity.
The alkalinity may be determined from the same sample tested for causticity
by the coloring with methylorange and adding the acid until the sample is on
the point of turning red. The total acid added in determining both causticity
and alkalinity in this case is the measure of the alkalinity.
Hardness: 100 cubic centimeters of the treated water is used for this test, one
cubic centimeter of the soap solution corresponding to one degree of
hardness. The soap solution is added a very little at a time and the whole
violently shaken. Enough of the solution must be added to make a permanent
lather or foam, that is, the soap bubbles must not disappear after the shaking
is stopped.
Page 145
Excess of lime as determined by nitrate of silver: If there is an excess of lime
used in the treatment, a sample will become a dark brown by the addition of
a small quantity of silver nitrate, otherwise a milky white solution will be
formed.
Combined Heat and Chemical Treatment: Heat is used in many systems of
feed treatment apparatus as an adjunct to the chemical process. Heat alone
will remove temporary hardness by the precipitation of carbonates of lime
and magnesia and, when used in connection with the chemical process,
leaves only the permanent hardness or the sulphates of lime to be taken care
of by chemical treatment.
TABLE 16
REAGENTS REQUIRED IN LIME AND SODA PROCESS
FOR TREATING 1000 U. S. GALLONS OF WATER
PER GRAIN PER GALLON OF CONTAINED IMPURITIES[16]
Lime[17] Soda[18] Lime[17] Soda[18]
Pounds Pounds Pounds Pounds
Calcium Carbonate 0.098 … Ferrous Carbonate 0.169 …
Calcium Sulphate … 0.124 Ferrous Sulphate 0.070 0.110
Calcium Chloride … 0.151 Ferric Sulphate 0.074 0.126
Aluminum
Calcium Nitrate … 0.104 0.087 0.147
Sulphate
Magnesium Free Sulphuric
0.234 … 0.100 0.171
Carbonate Acid
Magnesium
0.079 0.141 Sodium Carbonate 0.093 …
Sulphate
Magnesium Free Carbon
0.103 0.177 0.223 …
Chloride Dioxide
Magnesium Nitrate 0.067 0.115 Hydrogen Sulphite 0.288 …
The chemicals used in the ordinary lime and soda process of feed water
treatment are common lime and soda. The efficiency of such apparatus will
depend wholly upon the amount and character of the impurities in the water
to be treated. Table 16 gives the amount of lime and soda required per 1000
gallons for each grain per gallon of the various impurities found in the water.
used in the treatment, a sample will become a dark brown by the addition of
a small quantity of silver nitrate, otherwise a milky white solution will be
formed.
Combined Heat and Chemical Treatment: Heat is used in many systems of
feed treatment apparatus as an adjunct to the chemical process. Heat alone
will remove temporary hardness by the precipitation of carbonates of lime
and magnesia and, when used in connection with the chemical process,
leaves only the permanent hardness or the sulphates of lime to be taken care
of by chemical treatment.
TABLE 16
REAGENTS REQUIRED IN LIME AND SODA PROCESS
FOR TREATING 1000 U. S. GALLONS OF WATER
PER GRAIN PER GALLON OF CONTAINED IMPURITIES[16]
Lime[17] Soda[18] Lime[17] Soda[18]
Pounds Pounds Pounds Pounds
Calcium Carbonate 0.098 … Ferrous Carbonate 0.169 …
Calcium Sulphate … 0.124 Ferrous Sulphate 0.070 0.110
Calcium Chloride … 0.151 Ferric Sulphate 0.074 0.126
Aluminum
Calcium Nitrate … 0.104 0.087 0.147
Sulphate
Magnesium Free Sulphuric
0.234 … 0.100 0.171
Carbonate Acid
Magnesium
0.079 0.141 Sodium Carbonate 0.093 …
Sulphate
Magnesium Free Carbon
0.103 0.177 0.223 …
Chloride Dioxide
Magnesium Nitrate 0.067 0.115 Hydrogen Sulphite 0.288 …
The chemicals used in the ordinary lime and soda process of feed water
treatment are common lime and soda. The efficiency of such apparatus will
depend wholly upon the amount and character of the impurities in the water
to be treated. Table 16 gives the amount of lime and soda required per 1000
gallons for each grain per gallon of the various impurities found in the water.
Page 146
This table is based on lime containing 90 per cent calcium oxide and soda
containing 58 per cent sodium oxide, [Pg 106] which correspond to the
commercial quality ordinarily purchasable. From this table and the cost of
the lime and soda, the cost of treating any water per 1000 gallons may be
readily computed.
Less Usual Reagents—Barium hydrate is sometimes used to reduce
permanent hardness or the calcium sulphate component. Until recently, the
high cost of barium hydrate has rendered its use prohibitive but at the
present it is obtained as a by-product in cement manufacture and it may be
purchased at a more reasonable figure than heretofore. It acts directly on the
soluble sulphates to form barium sulphate which is insoluble and may be
precipitated. Where this reagent is used, it is desirable that the reaction be
allowed to take place outside of the boiler, though there are certain cases
where its internal use is permissible.
Barium carbonate is sometimes used in removing calcium sulphate, the
products of the reaction being barium sulphate and calcium carbonate, both
of which are insoluble and may be precipitated. As barium carbonate in itself
is insoluble, it cannot be added to water as a solution and its use should,
therefore, be confined to treatment outside of the boiler.
Silicate of soda will precipitate calcium carbonate with the formation of a
gelatinous silicate of lime and carbonate of soda. If calcium sulphate is also
present, carbonate of soda is formed in the above reaction, which in turn will
break down the sulphate.
Oxalate of soda is an expensive but efficient reagent which forms a
precipitate of calcium oxalate of a particularly insoluble nature.
Alum and iron alum will act as efficient coagulents where organic matter is
present in the water. Iron alum has not only this property but also that of
reducing oil discharged from surface condensers to a condition in which it
may be readily removed by filtration.
Corrosion—Where there is a corrosive action because of the presence of
acid in the water or of oil containing fatty acids which will decompose and
cause pitting wherever the sludge can find a resting place, it may be
containing 58 per cent sodium oxide, [Pg 106] which correspond to the
commercial quality ordinarily purchasable. From this table and the cost of
the lime and soda, the cost of treating any water per 1000 gallons may be
readily computed.
Less Usual Reagents—Barium hydrate is sometimes used to reduce
permanent hardness or the calcium sulphate component. Until recently, the
high cost of barium hydrate has rendered its use prohibitive but at the
present it is obtained as a by-product in cement manufacture and it may be
purchased at a more reasonable figure than heretofore. It acts directly on the
soluble sulphates to form barium sulphate which is insoluble and may be
precipitated. Where this reagent is used, it is desirable that the reaction be
allowed to take place outside of the boiler, though there are certain cases
where its internal use is permissible.
Barium carbonate is sometimes used in removing calcium sulphate, the
products of the reaction being barium sulphate and calcium carbonate, both
of which are insoluble and may be precipitated. As barium carbonate in itself
is insoluble, it cannot be added to water as a solution and its use should,
therefore, be confined to treatment outside of the boiler.
Silicate of soda will precipitate calcium carbonate with the formation of a
gelatinous silicate of lime and carbonate of soda. If calcium sulphate is also
present, carbonate of soda is formed in the above reaction, which in turn will
break down the sulphate.
Oxalate of soda is an expensive but efficient reagent which forms a
precipitate of calcium oxalate of a particularly insoluble nature.
Alum and iron alum will act as efficient coagulents where organic matter is
present in the water. Iron alum has not only this property but also that of
reducing oil discharged from surface condensers to a condition in which it
may be readily removed by filtration.
Corrosion—Where there is a corrosive action because of the presence of
acid in the water or of oil containing fatty acids which will decompose and
cause pitting wherever the sludge can find a resting place, it may be
Page 147
overcome by the neutralization of the water by carbonate of soda. Such
neutralization should be carried to the point where the water will just turn
red litmus paper blue. As a preventative of such action arising from the
presence of the oil, only the highest grades of hydrocarbon oils should be
used.
Acidity will occur where sea water is present in a boiler. There is the
possibility of such an occurrence in marine practice and in stationary plants
using sea water for condensing, due to leaky condenser tubes, priming in the
evaporators, etc. Such acidity is caused through the dissociation of
magnesium chloride into hydrochloride acid and magnesia under high
temperatures. The acid in contact with the metal forms an iron salt which
immediately upon its formation is neutralized by the free magnesia in the
water, thereby precipitating iron oxide and reforming magnesium chloride.
The preventive for corrosion arising from such acidity is the keeping tight of
the condenser. Where it is unavoidable that some sea water should find its
way into a boiler, the acidity resulting should be neutralized by soda ash.
This will convert the magnesium chloride into magnesium carbonate and
sodium chloride, neither of which is corrosive but both of which are scale-
forming.
The presence of air in the feed water which is sucked in by the feed pump is
a well recognized cause of corrosion. Air bubbles form below the water line
and attack [Pg 107] the metal of the boiler, the oxygen of the air causing
oxidization of the boiler metal and the formation of rust. The particle of rust
thus formed is swept away by the circulation or is dislodged by expansion
and the minute pit thus left forms an ideal resting place for other air bubbles
and the continuation of the oxidization process. The prevention is, of course,
the removing of the air from the feed water. In marine practice, where there
has been experienced the most difficulty from this source, it has been found
to be advantageous to pump the water from the hot well to a filter tank
placed above the feed pump suction valves. In this way the air is liberated
from the surface of the tank and a head is assured for the suction end of the
pump. In this same class of work, the corrosive action of air is reduced by
introducing the feed through a spray nozzle into the steam space above the
water line.
neutralization should be carried to the point where the water will just turn
red litmus paper blue. As a preventative of such action arising from the
presence of the oil, only the highest grades of hydrocarbon oils should be
used.
Acidity will occur where sea water is present in a boiler. There is the
possibility of such an occurrence in marine practice and in stationary plants
using sea water for condensing, due to leaky condenser tubes, priming in the
evaporators, etc. Such acidity is caused through the dissociation of
magnesium chloride into hydrochloride acid and magnesia under high
temperatures. The acid in contact with the metal forms an iron salt which
immediately upon its formation is neutralized by the free magnesia in the
water, thereby precipitating iron oxide and reforming magnesium chloride.
The preventive for corrosion arising from such acidity is the keeping tight of
the condenser. Where it is unavoidable that some sea water should find its
way into a boiler, the acidity resulting should be neutralized by soda ash.
This will convert the magnesium chloride into magnesium carbonate and
sodium chloride, neither of which is corrosive but both of which are scale-
forming.
The presence of air in the feed water which is sucked in by the feed pump is
a well recognized cause of corrosion. Air bubbles form below the water line
and attack [Pg 107] the metal of the boiler, the oxygen of the air causing
oxidization of the boiler metal and the formation of rust. The particle of rust
thus formed is swept away by the circulation or is dislodged by expansion
and the minute pit thus left forms an ideal resting place for other air bubbles
and the continuation of the oxidization process. The prevention is, of course,
the removing of the air from the feed water. In marine practice, where there
has been experienced the most difficulty from this source, it has been found
to be advantageous to pump the water from the hot well to a filter tank
placed above the feed pump suction valves. In this way the air is liberated
from the surface of the tank and a head is assured for the suction end of the
pump. In this same class of work, the corrosive action of air is reduced by
introducing the feed through a spray nozzle into the steam space above the
water line.
Page 148
Galvanic action, resulting in the eating away of the boiler metal through
electrolysis was formerly considered practically the sole cause of corrosion.
But little is known of such action aside from the fact that it does take place
in certain instances. The means adopted as a remedy is usually the
installation of zinc plates within the boiler, which must have positive
metallic contact with the boiler metal. In this way, local electrolytic effects
are overcome by a still greater electrolytic action at the expense of the more
positive zinc. The positive contact necessary is difficult to maintain and it is
questionable just what efficacy such plates have except for a short period
after their installation when the contact is known to be positive. Aside from
protection from such electrolytic action, however, the zinc plates have a
distinct use where there is the liability of air in the feed, as they offer a
substance much more readily oxidized by such air than the metal of the
boiler.
Foaming—Where foaming is caused by organic matter in suspension, it may
be largely overcome by filtration or by the use of a coagulent in connection
with filtration, the latter combination having come recently into considerable
favor. Alum, or potash alum, and iron alum, which in reality contains no
alumina and should rather be called potassia-ferric, are the coagulents
generally used in connection with filtration. Such matter as is not removed
by filtration may, under certain conditions, be handled by surface blowing.
In some instances, settling tanks are used for the removal of matter in
suspension, but where large quantities of water are required, filtration is
ordinarily substituted on account of the time element and the large area
necessary in settling tanks.
Where foaming occurs as the result of overtreatment of the feed water, the
obvious remedy is a change in such treatment.
Priming—Where priming is caused by excessive concentration of salts
within a boiler, it may be overcome largely by frequent blowing down. The
degree of concentration allowable before priming will take place varies
widely with conditions of operation and may be definitely determined only
by experience with each individual set of conditions. It is the presence of the
salts that cause priming that may result in the absolute unfitness of water for
boiler feed purposes. Where these salts exist in such quantities that the
amount of blowing down necessary to keep the degree of concentration
electrolysis was formerly considered practically the sole cause of corrosion.
But little is known of such action aside from the fact that it does take place
in certain instances. The means adopted as a remedy is usually the
installation of zinc plates within the boiler, which must have positive
metallic contact with the boiler metal. In this way, local electrolytic effects
are overcome by a still greater electrolytic action at the expense of the more
positive zinc. The positive contact necessary is difficult to maintain and it is
questionable just what efficacy such plates have except for a short period
after their installation when the contact is known to be positive. Aside from
protection from such electrolytic action, however, the zinc plates have a
distinct use where there is the liability of air in the feed, as they offer a
substance much more readily oxidized by such air than the metal of the
boiler.
Foaming—Where foaming is caused by organic matter in suspension, it may
be largely overcome by filtration or by the use of a coagulent in connection
with filtration, the latter combination having come recently into considerable
favor. Alum, or potash alum, and iron alum, which in reality contains no
alumina and should rather be called potassia-ferric, are the coagulents
generally used in connection with filtration. Such matter as is not removed
by filtration may, under certain conditions, be handled by surface blowing.
In some instances, settling tanks are used for the removal of matter in
suspension, but where large quantities of water are required, filtration is
ordinarily substituted on account of the time element and the large area
necessary in settling tanks.
Where foaming occurs as the result of overtreatment of the feed water, the
obvious remedy is a change in such treatment.
Priming—Where priming is caused by excessive concentration of salts
within a boiler, it may be overcome largely by frequent blowing down. The
degree of concentration allowable before priming will take place varies
widely with conditions of operation and may be definitely determined only
by experience with each individual set of conditions. It is the presence of the
salts that cause priming that may result in the absolute unfitness of water for
boiler feed purposes. Where these salts exist in such quantities that the
amount of blowing down necessary to keep the degree of concentration
Page 149
below the priming point results in excessive losses, the only remedy is the
securing of another supply of feed, and the results will warrant the change
almost regardless of the expense. In some few instances, the impurities may
be taken care of by some method of water treatment but such water should
be submitted to an authority on the subject before any treatment apparatus is
installed.
[Pg 108]
[Pg 109] Boiler Compounds—The method of treatment of feed water by far
the most generally used is by the use of some of the so-called boiler
compounds. There are many reliable concerns handling such compounds
who unquestionably secure the promised results, but there is a great
tendency toward looking on the compound as a “cure all” for any water
difficulties and care should be taken to deal only with reputable concerns.
securing of another supply of feed, and the results will warrant the change
almost regardless of the expense. In some few instances, the impurities may
be taken care of by some method of water treatment but such water should
be submitted to an authority on the subject before any treatment apparatus is
installed.
[Pg 108]
[Pg 109] Boiler Compounds—The method of treatment of feed water by far
the most generally used is by the use of some of the so-called boiler
compounds. There are many reliable concerns handling such compounds
who unquestionably secure the promised results, but there is a great
tendency toward looking on the compound as a “cure all” for any water
difficulties and care should be taken to deal only with reputable concerns.
Page 150
3000 Horse-power Installation of Cross Drum Babcock & Wilcox
Boilers and Superheaters Equipped with Babcock & Wilcox Chain
Grate Stokers at the Washington Terminal Co., Washington, D. C.
The composition of these compounds is almost invariably based on soda
with certain tannic substances and in some instances a gelatinous substance
which is presumed to encircle scale particles and prevent their adhering to
the boiler surfaces. The action of these compounds is ordinarily to reduce the
calcium sulphate in the water by means of carbonate of soda and to
precipitate it as a muddy form of calcium carbonate which may be blown
off. The tannic compounds are used in connection with the soda with the
Boilers and Superheaters Equipped with Babcock & Wilcox Chain
Grate Stokers at the Washington Terminal Co., Washington, D. C.
The composition of these compounds is almost invariably based on soda
with certain tannic substances and in some instances a gelatinous substance
which is presumed to encircle scale particles and prevent their adhering to
the boiler surfaces. The action of these compounds is ordinarily to reduce the
calcium sulphate in the water by means of carbonate of soda and to
precipitate it as a muddy form of calcium carbonate which may be blown
off. The tannic compounds are used in connection with the soda with the
Page 151
idea of introducing organic matter into any scale already formed. When it
has penetrated to the boiler metal, decomposition of the scale sets in, causing
a disruptive effect which breaks the scale from the metal sometimes in large
slabs. It is this effect of boiler compounds that is to be most carefully
guarded against or inevitable trouble will result from the presence of loose
scale with the consequent danger of tube losses through burning.
When proper care is taken to suit the compound to the water in use, the
results secured are fairly effective. In general, however, the use of
compounds may only be recommended for the prevention of scale rather
than with the view to removing scale which has already formed, that is, the
compounds should be introduced with the feed water only when the boiler
has been thoroughly cleaned.
FOOTNOTES
[15] Some waters, not naturally acid, become so at high temperatures, as when
chloride of magnesia decomposes with the formation of free hydrochloride acid;
such phenomena become more serious with an increase in pressure and
temperature.
[16] L. M. Booth Company.
[17] Based on lime containing 90 per cent calcium oxide.
[18] Based on soda containing 58 per cent sodium oxide.
has penetrated to the boiler metal, decomposition of the scale sets in, causing
a disruptive effect which breaks the scale from the metal sometimes in large
slabs. It is this effect of boiler compounds that is to be most carefully
guarded against or inevitable trouble will result from the presence of loose
scale with the consequent danger of tube losses through burning.
When proper care is taken to suit the compound to the water in use, the
results secured are fairly effective. In general, however, the use of
compounds may only be recommended for the prevention of scale rather
than with the view to removing scale which has already formed, that is, the
compounds should be introduced with the feed water only when the boiler
has been thoroughly cleaned.
FOOTNOTES
[15] Some waters, not naturally acid, become so at high temperatures, as when
chloride of magnesia decomposes with the formation of free hydrochloride acid;
such phenomena become more serious with an increase in pressure and
temperature.
[16] L. M. Booth Company.
[17] Based on lime containing 90 per cent calcium oxide.
[18] Based on soda containing 58 per cent sodium oxide.
Page 152
[Pg 110]
Page 153
FEED WATER HEATING AND METHODS OF
FEEDING
Before water fed into a boiler can be converted into steam, it must be first heated to a
temperature corresponding to the pressure within the boiler. Steam at 160 pounds gauge
pressure has a temperature of approximately 371 degrees Fahrenheit. If water is fed to
the boiler at 60 degrees Fahrenheit, each pound must have 311 B. t. u. added to it to
increase its temperature 371 degrees, which increase must take place before the water
can be converted into steam. As it requires 1167.8 B. t. u. to raise one pound of water
from 60 to 371 degrees and to convert it into steam at 160 pounds gauge pressure, the
311 degrees required simply to raise the temperature of the water from 60 to 371
degrees will be approximately 27 per cent of the total. If, therefore, the temperature of
the water can be increased from 60 to 371 degrees before it is introduced into a boiler
by the utilization of heat from some source that would otherwise be wasted, there will
be a saving in the fuel required of 311 ÷ 1167.8 = 27 per cent, and there will be a net
saving, provided the cost of maintaining and operating the apparatus for securing this
saving is less than the value of the heat thus saved.
The saving in the fuel due to the heating of feed water by means of heat that would
otherwise be wasted may be computed from the formula:
100 (t − ti)
Fuel saving per cent = –––––––––––––––––– (1)
H + 32 − ti
where, t = temperature of feed water after heating, ti = temperature of feed water before
heating, and H = total heat above 32 degrees per pound of steam at the boiler pressure.
Values of H may be found in Table 23. Table 17 has been computed from this formula
to show the fuel saving under the conditions assumed with the boiler operating at 180
pounds gauge pressure.
TABLE 17
SAVING IN FUEL, IN PER CENT, BY HEATING FEED WATER
GAUGE PRESSURE 180 POUNDS
Init’l Final Temperature—Degrees Init’l Final Temperature—Degrees
Temp. Fahrenheit Temp. Fahrenheit
° °
Fahr. 120 140 160 180 200 250 300 Fahr. 120 140 160 180 200 250 300
FEEDING
Before water fed into a boiler can be converted into steam, it must be first heated to a
temperature corresponding to the pressure within the boiler. Steam at 160 pounds gauge
pressure has a temperature of approximately 371 degrees Fahrenheit. If water is fed to
the boiler at 60 degrees Fahrenheit, each pound must have 311 B. t. u. added to it to
increase its temperature 371 degrees, which increase must take place before the water
can be converted into steam. As it requires 1167.8 B. t. u. to raise one pound of water
from 60 to 371 degrees and to convert it into steam at 160 pounds gauge pressure, the
311 degrees required simply to raise the temperature of the water from 60 to 371
degrees will be approximately 27 per cent of the total. If, therefore, the temperature of
the water can be increased from 60 to 371 degrees before it is introduced into a boiler
by the utilization of heat from some source that would otherwise be wasted, there will
be a saving in the fuel required of 311 ÷ 1167.8 = 27 per cent, and there will be a net
saving, provided the cost of maintaining and operating the apparatus for securing this
saving is less than the value of the heat thus saved.
The saving in the fuel due to the heating of feed water by means of heat that would
otherwise be wasted may be computed from the formula:
100 (t − ti)
Fuel saving per cent = –––––––––––––––––– (1)
H + 32 − ti
where, t = temperature of feed water after heating, ti = temperature of feed water before
heating, and H = total heat above 32 degrees per pound of steam at the boiler pressure.
Values of H may be found in Table 23. Table 17 has been computed from this formula
to show the fuel saving under the conditions assumed with the boiler operating at 180
pounds gauge pressure.
TABLE 17
SAVING IN FUEL, IN PER CENT, BY HEATING FEED WATER
GAUGE PRESSURE 180 POUNDS
Init’l Final Temperature—Degrees Init’l Final Temperature—Degrees
Temp. Fahrenheit Temp. Fahrenheit
° °
Fahr. 120 140 160 180 200 250 300 Fahr. 120 140 160 180 200 250 300
Page 154
32 7.359.02 10.69 12.36 14.0418.20 22.38 95 2.203.975.73 7.499.25 13.6618.07
35 7.128.79 10.46 12.14 13.8218.00 22.18 100 1.773.545.31 7.088.85 13.2817.70
40 6.728.41 10.09 11.77 13.4517.65 21.86 110 .892.684.47 6.258.04 12.5016.97
45 6.338.02 9.71 11.40 13.0817.30 21.52 120 .001.803.61 5.417.21 11.71 16.22
50 5.937.63 9.32 11.02 12.7216.95 21.19 130 .912.73 4.556.37 10.9115.46
55 5.537.24 8.94 10.64 12.3416.60 20.86 140 .001.84 3.675.51 10.0914.68
60 5.136.84 8.55 10.27 11.97 16.24 20.52 150 .93 2.784.63 9.2613.89
65 4.726.44 8.16 9.87 11.59 15.88 20.18 160 .00 1.873.74 8.4113.09
70 4.316.04 7.77 9.48 11.21 15.52 19.83 170 .942.83 7.5512.27
75 3.905.64 7.36 9.09 10.8215.16 19.48 180 .001.91 6.67 11.43
80 3.485.22 6.96 8.70 10.4414.79 19.13 190 .96 5.7710.58
85 3.064.80 6.55 8.30 10.0514.41 18.78 200 .00 4.86 9.71
90 2.634.39 6.14 7.89 9.6514.04 18.43 210 3.92 8.82
[Pg 111]
Besides the saving in fuel effected by the use of feed water heaters, other advantages
are secured. The time required for the conversion of water into steam is diminished and
the steam capacity of the boiler thereby increased. Further, the feeding of cold water
into a boiler has a tendency toward the setting up of temperature strains, which are
diminished in proportion as the temperature of the feed approaches that of the steam.
An important additional advantage of heating feed water is that in certain types of
heaters a large portion of the scale forming ingredients are precipitated before entering
the boiler, with a consequent saving in cleaning and losses through decreased efficiency
and capacity.
In general, feed water heaters may be divided into closed heaters, open heaters and
economizers; the first two depend for their heat upon exhaust, or in some cases live
steam, while the last class utilizes the heat of the waste flue gases to secure the same
result. The question of the type of apparatus to be installed is dependent upon the
conditions attached to each individual case.
In closed heaters the feed water and the exhaust steam do not come into actual contact
with each other. Either the steam or the water passes through tubes surrounded by the
other medium, as the heater is of the steam-tube or water-tube type. A closed heater is
best suited for water free from scale-forming matter, as such matter soon clogs the
passages. Cleaning such heaters is costly and the efficiency drops off rapidly as scale
forms. A closed heater is not advisable where the engines work intermittently, as is the
case with mine hoisting engines. In this class of work the frequent coolings between
operating periods and the sudden heatings when operation commences will tend to
loosen the tubes or even pull them apart. For this reason, an open heater, or economizer,
will give more satisfactory service with intermittently operating apparatus.
35 7.128.79 10.46 12.14 13.8218.00 22.18 100 1.773.545.31 7.088.85 13.2817.70
40 6.728.41 10.09 11.77 13.4517.65 21.86 110 .892.684.47 6.258.04 12.5016.97
45 6.338.02 9.71 11.40 13.0817.30 21.52 120 .001.803.61 5.417.21 11.71 16.22
50 5.937.63 9.32 11.02 12.7216.95 21.19 130 .912.73 4.556.37 10.9115.46
55 5.537.24 8.94 10.64 12.3416.60 20.86 140 .001.84 3.675.51 10.0914.68
60 5.136.84 8.55 10.27 11.97 16.24 20.52 150 .93 2.784.63 9.2613.89
65 4.726.44 8.16 9.87 11.59 15.88 20.18 160 .00 1.873.74 8.4113.09
70 4.316.04 7.77 9.48 11.21 15.52 19.83 170 .942.83 7.5512.27
75 3.905.64 7.36 9.09 10.8215.16 19.48 180 .001.91 6.67 11.43
80 3.485.22 6.96 8.70 10.4414.79 19.13 190 .96 5.7710.58
85 3.064.80 6.55 8.30 10.0514.41 18.78 200 .00 4.86 9.71
90 2.634.39 6.14 7.89 9.6514.04 18.43 210 3.92 8.82
[Pg 111]
Besides the saving in fuel effected by the use of feed water heaters, other advantages
are secured. The time required for the conversion of water into steam is diminished and
the steam capacity of the boiler thereby increased. Further, the feeding of cold water
into a boiler has a tendency toward the setting up of temperature strains, which are
diminished in proportion as the temperature of the feed approaches that of the steam.
An important additional advantage of heating feed water is that in certain types of
heaters a large portion of the scale forming ingredients are precipitated before entering
the boiler, with a consequent saving in cleaning and losses through decreased efficiency
and capacity.
In general, feed water heaters may be divided into closed heaters, open heaters and
economizers; the first two depend for their heat upon exhaust, or in some cases live
steam, while the last class utilizes the heat of the waste flue gases to secure the same
result. The question of the type of apparatus to be installed is dependent upon the
conditions attached to each individual case.
In closed heaters the feed water and the exhaust steam do not come into actual contact
with each other. Either the steam or the water passes through tubes surrounded by the
other medium, as the heater is of the steam-tube or water-tube type. A closed heater is
best suited for water free from scale-forming matter, as such matter soon clogs the
passages. Cleaning such heaters is costly and the efficiency drops off rapidly as scale
forms. A closed heater is not advisable where the engines work intermittently, as is the
case with mine hoisting engines. In this class of work the frequent coolings between
operating periods and the sudden heatings when operation commences will tend to
loosen the tubes or even pull them apart. For this reason, an open heater, or economizer,
will give more satisfactory service with intermittently operating apparatus.
Page 155
Open heaters are best suited for waters containing scale-forming matter. Much of the
temporary hardness may be precipitated in the heater and the sediment easily removed.
Such heaters are frequently used with a reagent for precipitating permanent hardness in
the combined heat and chemical treatment of feed water. The so-called live steam
purifiers are open heaters, the water being raised to the boiling temperature and the
carbonates and a portion of the sulphates being precipitated. The disadvantage of this
class of apparatus is that some of the sulphates remain in solution to be precipitated as
scale when concentrated in the boiler. Sufficient concentration to have such an effect,
however, may often be prevented by frequent blowing down.
Economizers find their largest field where the design of the boiler is such that the
maximum possible amount of heat is not extracted from the gases of combustion. The
more wasteful the boiler, the greater the saving effected by the use of the economizer,
and it is sometimes possible to raise the temperature of the feed water to that of high
pressure steam by the installation of such an apparatus, the saving amounting in some
cases to as much as 20 per cent. The fuel used bears directly on the question of the
advisability of an economizer installation, for when oil is the fuel a boiler efficiency of
80 per cent or over is frequently realized, an efficiency which would leave a small
opportunity for a commercial gain through the addition of an economizer.
From the standpoint of space requirements, economizers are at a disadvantage in that
they are bulky and require a considerable increase over space occupied by a heater of
the exhaust type. They also require additional brickwork or a metal casing, which
[Pg 112] increases the cost. Sometimes, too, the frictional resistance of the gases through
an economizer make its adaptability questionable because of the draft conditions. When
figuring the net return on economizer investment, all of these factors must be
considered.
When the feed water is such that scale will quickly encrust the economizer and throw it
out of service for cleaning during an excessive portion of the time, it will be necessary
to purify water before introducing it into an economizer to make it earn a profit on the
investment.
From the foregoing, it is clearly indicated that it is impossible to make a definite
statement as to the relative saving by heating feed water in any of the three types. Each
case must be worked out independently and a decision can be reached only after an
exhaustive study of all the conditions affecting the case, including the time the plant
will be in service and probable growth of the plant. When, as a result of such study, the
possible methods for handling the problem have been determined, the solution of the
best apparatus can be made easily by the balancing of the saving possible by each
method against its first cost, depreciation, maintenance and cost of operation.
temporary hardness may be precipitated in the heater and the sediment easily removed.
Such heaters are frequently used with a reagent for precipitating permanent hardness in
the combined heat and chemical treatment of feed water. The so-called live steam
purifiers are open heaters, the water being raised to the boiling temperature and the
carbonates and a portion of the sulphates being precipitated. The disadvantage of this
class of apparatus is that some of the sulphates remain in solution to be precipitated as
scale when concentrated in the boiler. Sufficient concentration to have such an effect,
however, may often be prevented by frequent blowing down.
Economizers find their largest field where the design of the boiler is such that the
maximum possible amount of heat is not extracted from the gases of combustion. The
more wasteful the boiler, the greater the saving effected by the use of the economizer,
and it is sometimes possible to raise the temperature of the feed water to that of high
pressure steam by the installation of such an apparatus, the saving amounting in some
cases to as much as 20 per cent. The fuel used bears directly on the question of the
advisability of an economizer installation, for when oil is the fuel a boiler efficiency of
80 per cent or over is frequently realized, an efficiency which would leave a small
opportunity for a commercial gain through the addition of an economizer.
From the standpoint of space requirements, economizers are at a disadvantage in that
they are bulky and require a considerable increase over space occupied by a heater of
the exhaust type. They also require additional brickwork or a metal casing, which
[Pg 112] increases the cost. Sometimes, too, the frictional resistance of the gases through
an economizer make its adaptability questionable because of the draft conditions. When
figuring the net return on economizer investment, all of these factors must be
considered.
When the feed water is such that scale will quickly encrust the economizer and throw it
out of service for cleaning during an excessive portion of the time, it will be necessary
to purify water before introducing it into an economizer to make it earn a profit on the
investment.
From the foregoing, it is clearly indicated that it is impossible to make a definite
statement as to the relative saving by heating feed water in any of the three types. Each
case must be worked out independently and a decision can be reached only after an
exhaustive study of all the conditions affecting the case, including the time the plant
will be in service and probable growth of the plant. When, as a result of such study, the
possible methods for handling the problem have been determined, the solution of the
best apparatus can be made easily by the balancing of the saving possible by each
method against its first cost, depreciation, maintenance and cost of operation.
Page 156
Feeding of Water—The choice of methods to be used in introducing feed water into a
boiler lies between an injector and a pump. In most plants, an injector would not be
economical, as the water fed by such means must be cold, a fact which makes
impossible the use of a heater before the water enters the injector. Such a heater might
be installed between the injector and the boiler but as heat is added to the water in the
injector, the heater could not properly fulfill its function.
TABLE 18 The
inje
COMPARISON OF PUMPS AND INJECTORS ctor,
Method of Supplying cons
Relative amount of ider
Feed-water to Boiler.
coal required per Saving of fuel over ed
Temperature of feed-water
unit of time, the the amount required only
as delivered to the pump,
amount for a when the boiler in
or to injector,
direct-acting pump, is fed by a the
60 degrees Fahrenheit.
feeding water at direct-acting pump light
Rate of evaporation of
60 degrees without heater of a
boiler, to pounds of water
without a heater, Per Cent com
per pound of coal from and
being taken as unity bine
at 212 degrees Fahrenheit
Direct-acting Pump feeding water d
at 60 degrees without a heater 1.000 .0 heat
er
Injector feeding water at 150
and
degrees without a heater .985 1.5
pum
Injector feeding through p, is
a heater in which the water is clai
heated from 150 to 200 degrees .938 6.2 med
Direct-acting Pump feeding to
water through a heater in which it hav
is heated from 60 to 200 degrees .879 12.1 ea
Geared Pump run from the ther
engine, feeding water through a mal
heater in which it is heated effic
from 60 to 200 degrees .868 13.2 ienc
y of
100 per cent, since all of the heat in the steam used is returned to the boiler with the
water. This claim leads to an erroneous idea. If a pump is used in feeding the water to a
boiler and the heat in the exhaust from the pump is imparted to the feed water, the
pump has as high a thermal efficiency as the injector. The pump has the further
advantage that it uses so much less steam for the forcing of a given quantity [Pg 113] of
water into the boiler that it makes possible a greater saving through the use of the
boiler lies between an injector and a pump. In most plants, an injector would not be
economical, as the water fed by such means must be cold, a fact which makes
impossible the use of a heater before the water enters the injector. Such a heater might
be installed between the injector and the boiler but as heat is added to the water in the
injector, the heater could not properly fulfill its function.
TABLE 18 The
inje
COMPARISON OF PUMPS AND INJECTORS ctor,
Method of Supplying cons
Relative amount of ider
Feed-water to Boiler.
coal required per Saving of fuel over ed
Temperature of feed-water
unit of time, the the amount required only
as delivered to the pump,
amount for a when the boiler in
or to injector,
direct-acting pump, is fed by a the
60 degrees Fahrenheit.
feeding water at direct-acting pump light
Rate of evaporation of
60 degrees without heater of a
boiler, to pounds of water
without a heater, Per Cent com
per pound of coal from and
being taken as unity bine
at 212 degrees Fahrenheit
Direct-acting Pump feeding water d
at 60 degrees without a heater 1.000 .0 heat
er
Injector feeding water at 150
and
degrees without a heater .985 1.5
pum
Injector feeding through p, is
a heater in which the water is clai
heated from 150 to 200 degrees .938 6.2 med
Direct-acting Pump feeding to
water through a heater in which it hav
is heated from 60 to 200 degrees .879 12.1 ea
Geared Pump run from the ther
engine, feeding water through a mal
heater in which it is heated effic
from 60 to 200 degrees .868 13.2 ienc
y of
100 per cent, since all of the heat in the steam used is returned to the boiler with the
water. This claim leads to an erroneous idea. If a pump is used in feeding the water to a
boiler and the heat in the exhaust from the pump is imparted to the feed water, the
pump has as high a thermal efficiency as the injector. The pump has the further
advantage that it uses so much less steam for the forcing of a given quantity [Pg 113] of
water into the boiler that it makes possible a greater saving through the use of the
Page 157
exhaust from other auxiliaries for heating the feed, which exhaust, if an injector were
used, would be wasted, as has been pointed out.
In locomotive practice, injectors are used because there is no exhaust steam available
for heating the feed, this being utilized in producing a forced draft, and because of
space requirements. In power plant work, however, pumps are universally used for
regular operation, though injectors are sometimes installed as an auxiliary method of
feeding.
Table 18 shows the relative value of injectors, direct-acting steam pumps and pumps
driven from the engine, the data having been obtained from actual experiment. It will
be noted that when feeding cold water direct to the boilers, the injector has a slightly
greater economy but when feeding through a heater, the pump is by far the more
economical.
Auxiliaries—It is the general impression that auxiliaries will take less steam if the
exhaust is turned into the condensers, in this way reducing the back pressure. As a
matter of fact, vacuum is rarely registered on an indicator card taken from the cylinders
of certain types of auxiliaries unless the exhaust connection is short and without bends,
as long pipes and many angles offset the effect of the condenser. On the other hand, if
the exhaust steam from the auxiliaries can be used for heating the feed water, all of the
latent heat less only the loss due to radiation is returned to the boiler and is saved
instead of being lost in the condensing water or wasted with the free exhaust. Taking
into consideration the plant as a whole, it would appear that the auxiliary machinery,
under such conditions, is more efficient than the main engines. [Pg 114]
used, would be wasted, as has been pointed out.
In locomotive practice, injectors are used because there is no exhaust steam available
for heating the feed, this being utilized in producing a forced draft, and because of
space requirements. In power plant work, however, pumps are universally used for
regular operation, though injectors are sometimes installed as an auxiliary method of
feeding.
Table 18 shows the relative value of injectors, direct-acting steam pumps and pumps
driven from the engine, the data having been obtained from actual experiment. It will
be noted that when feeding cold water direct to the boilers, the injector has a slightly
greater economy but when feeding through a heater, the pump is by far the more
economical.
Auxiliaries—It is the general impression that auxiliaries will take less steam if the
exhaust is turned into the condensers, in this way reducing the back pressure. As a
matter of fact, vacuum is rarely registered on an indicator card taken from the cylinders
of certain types of auxiliaries unless the exhaust connection is short and without bends,
as long pipes and many angles offset the effect of the condenser. On the other hand, if
the exhaust steam from the auxiliaries can be used for heating the feed water, all of the
latent heat less only the loss due to radiation is returned to the boiler and is saved
instead of being lost in the condensing water or wasted with the free exhaust. Taking
into consideration the plant as a whole, it would appear that the auxiliary machinery,
under such conditions, is more efficient than the main engines. [Pg 114]
Page 158
Portion of 4160 Horse-power Installation of Babcock & Wilcox Boilers at the
Prudential Life Insurance Co. Building, Newark, N. J.
Prudential Life Insurance Co. Building, Newark, N. J.
Page 159
[Pg 115]
Page 160
STEAM
When a given weight of a perfect gas is compressed or expanded at a constant temperature, the product of the
pressure and volume is a constant. Vapors, which are liquids in aeriform condition, on the other hand, can exist
only at a definite pressure corresponding to each temperature if in the saturated state, that is, the pressure is a
function of the temperature only. Steam is water vapor, and at a pressure of, say, 150 pounds absolute per square
inch saturated steam can exist only at a temperature 358 degrees Fahrenheit. Hence if the pressure of saturated
steam be fixed, its temperature is also fixed, and vice versa .
Saturated steam is water vapor in the condition in which it is generated from water with which it is in contact. Or it
is steam which is at the maximum pressure and density possible at its temperature. If any change be made in the
temperature or pressure of steam, there will be a corresponding change in its condition. If the pressure be increased
or the temperature decreased, a portion of the steam will be condensed. If the temperature be increased or the
pressure decreased, a portion of the water with which the steam is in contact will be evaporated into steam. Steam
will remain saturated just so long as it is of the same pressure and temperature as the water with which it can
remain in contact without a gain or loss of heat. Moreover, saturated steam cannot have its temperature lowered
without a lowering of its pressure, any loss of heat being made up by the latent heat of such portion as will be
condensed. Nor can the temperature of saturated steam be increased except when accompanied by a corresponding
increase in pressure, any added heat being expended in the evaporation into steam of a portion of the water with
which it is in contact.
Dry saturated steam contains no water. In some cases, saturated steam is accompanied by water which is carried
along with it, either in the form of a spray or is blown along the surface of the piping, and the steam is then said to
be wet. The percentage weight of the steam in a mixture of steam and water is called the quality of the steam.
Thus, if in a mixture of 100 pounds of steam and water there is three-quarters of a pound of water, the quality of
the steam will be 99.25.
Heat may be added to steam not in contact with water, such an addition of heat resulting in an increase of
temperature and pressure if the volume be kept constant, or an increase in temperature and volume if the pressure
remain constant. Steam whose temperature thus exceeds that of saturated steam at a corresponding pressure is said
to be superheated and its properties approximate those of a perfect gas.
As pointed out in the chapter on heat, the heat necessary to raise one pound of water from 32 degrees Fahrenheit to
the point of ebullition is called the heat of the liquid . The heat absorbed during ebullition consists of that
necessary to dissociate the molecules, or the inner latent heat , and that necessary to overcome the resistance to the
increase in volume, or the outer latent heat . These two make up the latent heat of evaporation and the sum of this
latent heat of evaporation and the heat of the liquid make the total heat of the steam. These values for various
pressures are given in the steam tables , pages 122 to 127 .
The specific volume of saturated steam at any pressure is the volume in cubic feet of one pound of steam at that
pressure.
The density of saturated steam, that is, its weight per cubic foot, is obviously the reciprocal of the specific volume.
This density varies as the 16 ⁄ 17 power over the [Pg 116] ordinary range of pressures used in steam boiler work and
may be found by the formula, D = .003027 p .941 , which is correct within 0.15 per cent up to 250 pounds pressure.
The relative volume of steam is the ratio of the volume of a given weight to the volume of the same weight of
water at 39.2 degrees Fahrenheit and is equal to the specific volume times 62.427.
As vapors are liquids in their gaseous form and the boiling point is the point of change in this condition, it is clear
that this point is dependent upon the pressure under which the liquid exists. This fact is of great practical
importance in steam condenser work and in many operations involving boiling in an open vessel, since in the latter
case its altitude will have considerable influence. The relation between altitude and boiling point of water is shown
in Table 12 .
When a given weight of a perfect gas is compressed or expanded at a constant temperature, the product of the
pressure and volume is a constant. Vapors, which are liquids in aeriform condition, on the other hand, can exist
only at a definite pressure corresponding to each temperature if in the saturated state, that is, the pressure is a
function of the temperature only. Steam is water vapor, and at a pressure of, say, 150 pounds absolute per square
inch saturated steam can exist only at a temperature 358 degrees Fahrenheit. Hence if the pressure of saturated
steam be fixed, its temperature is also fixed, and vice versa .
Saturated steam is water vapor in the condition in which it is generated from water with which it is in contact. Or it
is steam which is at the maximum pressure and density possible at its temperature. If any change be made in the
temperature or pressure of steam, there will be a corresponding change in its condition. If the pressure be increased
or the temperature decreased, a portion of the steam will be condensed. If the temperature be increased or the
pressure decreased, a portion of the water with which the steam is in contact will be evaporated into steam. Steam
will remain saturated just so long as it is of the same pressure and temperature as the water with which it can
remain in contact without a gain or loss of heat. Moreover, saturated steam cannot have its temperature lowered
without a lowering of its pressure, any loss of heat being made up by the latent heat of such portion as will be
condensed. Nor can the temperature of saturated steam be increased except when accompanied by a corresponding
increase in pressure, any added heat being expended in the evaporation into steam of a portion of the water with
which it is in contact.
Dry saturated steam contains no water. In some cases, saturated steam is accompanied by water which is carried
along with it, either in the form of a spray or is blown along the surface of the piping, and the steam is then said to
be wet. The percentage weight of the steam in a mixture of steam and water is called the quality of the steam.
Thus, if in a mixture of 100 pounds of steam and water there is three-quarters of a pound of water, the quality of
the steam will be 99.25.
Heat may be added to steam not in contact with water, such an addition of heat resulting in an increase of
temperature and pressure if the volume be kept constant, or an increase in temperature and volume if the pressure
remain constant. Steam whose temperature thus exceeds that of saturated steam at a corresponding pressure is said
to be superheated and its properties approximate those of a perfect gas.
As pointed out in the chapter on heat, the heat necessary to raise one pound of water from 32 degrees Fahrenheit to
the point of ebullition is called the heat of the liquid . The heat absorbed during ebullition consists of that
necessary to dissociate the molecules, or the inner latent heat , and that necessary to overcome the resistance to the
increase in volume, or the outer latent heat . These two make up the latent heat of evaporation and the sum of this
latent heat of evaporation and the heat of the liquid make the total heat of the steam. These values for various
pressures are given in the steam tables , pages 122 to 127 .
The specific volume of saturated steam at any pressure is the volume in cubic feet of one pound of steam at that
pressure.
The density of saturated steam, that is, its weight per cubic foot, is obviously the reciprocal of the specific volume.
This density varies as the 16 ⁄ 17 power over the [Pg 116] ordinary range of pressures used in steam boiler work and
may be found by the formula, D = .003027 p .941 , which is correct within 0.15 per cent up to 250 pounds pressure.
The relative volume of steam is the ratio of the volume of a given weight to the volume of the same weight of
water at 39.2 degrees Fahrenheit and is equal to the specific volume times 62.427.
As vapors are liquids in their gaseous form and the boiling point is the point of change in this condition, it is clear
that this point is dependent upon the pressure under which the liquid exists. This fact is of great practical
importance in steam condenser work and in many operations involving boiling in an open vessel, since in the latter
case its altitude will have considerable influence. The relation between altitude and boiling point of water is shown
in Table 12 .
Page 161
The conditions of feed temperature and steam pressure in boiler tests, fuel performances and the like, will be found
to vary widely in different trials. In order to secure a means for comparison of different trials, it is necessary to
reduce all results to some common basis. The method which has been adopted for the reduction to a comparable
basis is to transform the evaporation under actual conditions of steam pressure and feed temperature which exist in
the trial to an equivalent evaporation under a set of standard conditions. These standard conditions presuppose a
feed water temperature of 212 degrees Fahrenheit and a steam pressure equal to the normal atmospheric pressure at
sea level, 14.7 pounds absolute. Under such conditions steam would be generated at a temperature of 212 degrees,
the temperature corresponding to atmospheric pressure at sea level, from water at 212 degrees. The weight of water
which would be evaporated under the assumed standard conditions by exactly the amount of heat absorbed by the
boiler under actual conditions existing in the trial, is, therefore, called the equivalent evaporation “from and at 212
degrees.”
The factor for reducing the weight of water actually converted into steam from the temperature of the feed, at the
steam pressure existing in the trial, to the equivalent evaporation under standard conditions is called the factor of
evaporation. This factor is the ratio of the total heat added to one pound of steam under the standard conditions to
the heat added to each pound of steam in heating the water from the temperature of the feed in the trial to the
temperature corresponding to the pressure existing in the trial. This heat added is obviously the difference between
the total heat of evaporation of the steam at the pressure existing in the trial and the heat of the liquid in the water
at the temperature at which it was fed in the trial. To illustrate by an example:
In a boiler trial the temperature of the feed water is 60 degrees Fahrenheit and the pressure under which steam is
delivered is 160.3 pounds gauge pressure or 175 pounds absolute pressure. The total heat of one pound of steam at
175 pounds pressure is 1195.9 B. t. u. measured above the standard temperature of 32 degrees Fahrenheit. But the
water fed to the boiler contained 28.08 B. t. u. as the heat of the liquid measured above 32 degrees Fahrenheit.
Therefore, to each pound of steam there has been added 1167.82 B. t. u. To evaporate one pound of water under
standard conditions would, on the other hand, have required but 970.4 B. t. u., which, as described, is the latent
heat of evaporation at 212 degrees Fahrenheit. Expressed differently, the total heat of one pound of steam at the
pressure corresponding to a temperature of 212 degrees is 1150.4 B. t. u. One pound of water at 212 degrees
[Pg 117] contains 180 B. t. u. of sensible heat above 32 degrees Fahrenheit. Hence, under standard conditions, 1150.4
- 180 = 970.4 B. t. u. is added in the changing of one pound of water into steam at atmospheric pressure and a
temperature of 212 degrees. This is in effect the definition of the latent heat of evaporation.
Hence, if conditions of the trial had been standard, only 970.4 B. t. u. would be required and the ratio of 1167.82 to
970.4 B. t. u. is the ratio determining the factor of evaporation. The factor in the assumed case is 1167.82 ÷ 970.4 =
1.2034 and if the same amount of heat had been absorbed under standard conditions as was absorbed in the trial
condition, 1.2034 times the amount of steam would have been generated. Expressed as a formula for use with any
set of conditions, the factor is,
H−h
F = –––––––––– (2)
970.4
Where H = the total heat of steam above 32 degrees Fahrenheit from steam tables,
h = sensible heat of feed water above 32 degrees Fahrenheit from Table 22 .
In the form above, the factor may be determined with either saturated or superheated steam, provided that in the
latter case values of H are available for varying degrees of superheat and pressures.
Where such values are not available, the form becomes,
H − h + s ( t sup − t sat )
F= (3)
––––––––––––––––––––––––––––––––––
970.4
Where s = mean specific heat of superheated steam at the pressure existing in the trial from saturated steam
to the temperature existing in the trial,
t sup = final temperature of steam,
to vary widely in different trials. In order to secure a means for comparison of different trials, it is necessary to
reduce all results to some common basis. The method which has been adopted for the reduction to a comparable
basis is to transform the evaporation under actual conditions of steam pressure and feed temperature which exist in
the trial to an equivalent evaporation under a set of standard conditions. These standard conditions presuppose a
feed water temperature of 212 degrees Fahrenheit and a steam pressure equal to the normal atmospheric pressure at
sea level, 14.7 pounds absolute. Under such conditions steam would be generated at a temperature of 212 degrees,
the temperature corresponding to atmospheric pressure at sea level, from water at 212 degrees. The weight of water
which would be evaporated under the assumed standard conditions by exactly the amount of heat absorbed by the
boiler under actual conditions existing in the trial, is, therefore, called the equivalent evaporation “from and at 212
degrees.”
The factor for reducing the weight of water actually converted into steam from the temperature of the feed, at the
steam pressure existing in the trial, to the equivalent evaporation under standard conditions is called the factor of
evaporation. This factor is the ratio of the total heat added to one pound of steam under the standard conditions to
the heat added to each pound of steam in heating the water from the temperature of the feed in the trial to the
temperature corresponding to the pressure existing in the trial. This heat added is obviously the difference between
the total heat of evaporation of the steam at the pressure existing in the trial and the heat of the liquid in the water
at the temperature at which it was fed in the trial. To illustrate by an example:
In a boiler trial the temperature of the feed water is 60 degrees Fahrenheit and the pressure under which steam is
delivered is 160.3 pounds gauge pressure or 175 pounds absolute pressure. The total heat of one pound of steam at
175 pounds pressure is 1195.9 B. t. u. measured above the standard temperature of 32 degrees Fahrenheit. But the
water fed to the boiler contained 28.08 B. t. u. as the heat of the liquid measured above 32 degrees Fahrenheit.
Therefore, to each pound of steam there has been added 1167.82 B. t. u. To evaporate one pound of water under
standard conditions would, on the other hand, have required but 970.4 B. t. u., which, as described, is the latent
heat of evaporation at 212 degrees Fahrenheit. Expressed differently, the total heat of one pound of steam at the
pressure corresponding to a temperature of 212 degrees is 1150.4 B. t. u. One pound of water at 212 degrees
[Pg 117] contains 180 B. t. u. of sensible heat above 32 degrees Fahrenheit. Hence, under standard conditions, 1150.4
- 180 = 970.4 B. t. u. is added in the changing of one pound of water into steam at atmospheric pressure and a
temperature of 212 degrees. This is in effect the definition of the latent heat of evaporation.
Hence, if conditions of the trial had been standard, only 970.4 B. t. u. would be required and the ratio of 1167.82 to
970.4 B. t. u. is the ratio determining the factor of evaporation. The factor in the assumed case is 1167.82 ÷ 970.4 =
1.2034 and if the same amount of heat had been absorbed under standard conditions as was absorbed in the trial
condition, 1.2034 times the amount of steam would have been generated. Expressed as a formula for use with any
set of conditions, the factor is,
H−h
F = –––––––––– (2)
970.4
Where H = the total heat of steam above 32 degrees Fahrenheit from steam tables,
h = sensible heat of feed water above 32 degrees Fahrenheit from Table 22 .
In the form above, the factor may be determined with either saturated or superheated steam, provided that in the
latter case values of H are available for varying degrees of superheat and pressures.
Where such values are not available, the form becomes,
H − h + s ( t sup − t sat )
F= (3)
––––––––––––––––––––––––––––––––––
970.4
Where s = mean specific heat of superheated steam at the pressure existing in the trial from saturated steam
to the temperature existing in the trial,
t sup = final temperature of steam,
Page 162
t sat = temperature of saturated steam, corresponding to pressure existing,
( t sup − t sat ) = degrees of superheat.
The specific heat of superheated steam will be taken up later.
Table 19 gives factors of evaporation for saturated steam boiler trials to cover a large range of conditions. Except
for the most refined work, intermediate values may be determined by interpolation.
Steam gauges indicate the pressure above the atmosphere. As has been pointed out, the atmospheric pressure
changes according to the altitude and the variation in the barometer. Hence, calculations involving the properties of
steam are based on absolute pressures, which are equal to the gauge pressure plus the atmospheric pressure in
pounds to the square inch. This latter is generally assumed to be 14.7 pounds per square inch at sea level, but for
other levels it must be determined from the barometric reading at that place.
Vacuum gauges indicate the difference, expressed in inches of mercury, between atmospheric pressure and the
pressure within the vessel to which the gauge is attached. For approximate purposes, 2.04 inches height of mercury
may be considered equal to a pressure of one pound per square inch at the ordinary temperatures at which mercury
gauges are used. Hence for any reading of the vacuum gauge in inches, G, the absolute pressure for any barometer
reading in inches, B, will be (B - G) ÷ 2.04. If the barometer is 30 inches measured at ordinary temperatures and
not corrected to 32 degrees Fahrenheit and the vacuum gauge 24 inches, the absolute pressure will be (30 - 24) ÷
2.04 = 2.9 pounds per square inch.
[Pg 118]
TABLE 19
FACTORS OF EVAPORATION
CALCULATED FROM MARKS AND DAVIS TABLES
Feed
Temp- Steam Pressure by Gauge
erature
Degrees
Fahren- 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240
heit
32 1.2143 1.2170 1.2194 1.2215 1.2233 1.2233 1.2265 1.2280 1.2292 1.2304 1.2314 1.2323 1.2333 1.2342 1.2350 1.2357 1.2364 1.2372 1.2378 1.2384 1
40 1.2060 1.2087 1.2111 1.2131 1.2150 1.2168 1.2181 1.2196 1.2209 1.2221 1.2231 1.2241 1.2250 1.2259 1.2267 1.2274 1.2282 1.2289 1.2295 1.2301 1
50 1.1957 1.1984 1.2008 1.2028 1.2047 1.2065 1.2079 1.2093 1.2106 1.2117 1.2128 1.2137 1.2147 1.2156 1.2164 1.2171 1.2178 1.2186 1.2192 1.2198 1
60 1.1854 1.1881 1.1905 1.1925 1.1944 1.1961 1.1976 1.1990 1.2003 1.2014 1.2025 1.2034 1.2044 1.2053 1.2061 1.2068 1.2075 1.2083 1.2089 1.2095 1
70 1.1750 1.1778 1.1802 1.1822 1.1841 1.1859 1.1873 1.1887 1.1900 1.1911 1.1922 1.1931 1.1941 1.1950 1.1958 1.1965 1.1972 1.1980 1.1986 1.1992 1
80 1.1649 1.1675 1.1699 1.1720 1.1738 1.1756 1.1770 1.1785 1.1797 1.1809 1.1819 1.1828 1.1838 1.1847 1.1855 1.1863 1.1869 1.1877 1.1883 1.1889 1
90 1.1545 1.1572 1.1596 1.1617 1.1636 1.1653 1.1668 1.1682 1.1695 1.1706 1.1717 1.1725 1.1735 1.1744 1.1750 1.1760 1.1766 1.1774 1.1780 1.1786 1
100 1.1443 1.1470 1.1493 1.1514 1.1533 1.1550 1.1565 1.1579 1.1592 1.1603 1.1614 1.1623 1.1633 1.1642 1.1650 1.1657 1.1664 1.1671 1.1678 1.1684 1
110 1.1340 1.1367 1.1391 1.1411 1.1430 1.1448 1.1462 1.1477 1.1489 1.1500 1.1511 1.1520 1.1530 1.1539 1.1547 1.1554 1.1562 1.1569 1.1575 1.1581 1
120 1.1237 1.1264 1.1288 1.1309 1.1327 1.1345 1.1359 1.1374 1.1386 1.1398 1.1408 1.1418 1.1427 1.1436 1.1444 1.1452 1.1459 1.1466 1.1472 1.1478 1
130 1.1134 1.1161 1.1185 1.1206 1.1225 1.1242 1.1257 1.1271 1.1284 1.1295 1.1305 1.1315 1.1324 1.1333 1.1341 1.1349 1.1356 1.1363 1.1369 1.1375 1
140 1.1031 1.1058 1.1082 1.1103 1.1122 1.1139 1.1154 1.1168 1.1181 1.1192 1.1203 1.1212 1.1221 1.1230 1.1239 1.1246 1.1253 1.1260 1.1266 1.1272 1
150 1.0928 1.0955 1.0979 1.1000 1.1019 1.1036 1.1051 1.1065 1.1078 1.1089 1.1099 1.1109 1.1118 1.1127 1.1136 1.1143 1.1150 1.1157 1.1163 1.1169 1
160 1.0825 1.0852 1.0876 1.0897 1.0916 1.0933 1.0948 1.0962 1.0975 1.0986 1.0997 1.1006 1.1015 1.1024 1.1033 1.1040 1.1047 1.1054 1.1060 1.1066 1
170 1.0722 1.0749 1.0773 1.0794 1.0813 1.0830 1.0845 1.0859 1.0872 1.0883 1.0893 1.0903 1.0912 1.0921 1.0930 1.0937 1.0944 1.0951 1.0957 1.0963 1
180 1.0619 1.0646 1.0670 1.0691 1.0709 1.0727 1.0741 1.0756 1.0768 1.0780 1.0790 1.0800 1.0809 1.0818 1.0826 1.0834 1.0841 1.0848 1.0854 1.0860 1
190 1.0516 1.0543 1.0567 1.0587 1.0606 1.0624 1.0638 1.0653 1.0665 1.0676 1.0687 1.0696 1.0706 1.0715 1.0723 1.0730 1.0737 1.0745 1.0751 1.0757 1
200 1.0412 1.0439 1.0463 1.0484 1.0503 1.0520 1.0535 1.0549 1.0562 1.0573 1.0584 1.0593 1.0602 1.0611 1.0620 1.0627 1.0634 1.0641 1.0647 1.0653 1
210 1.0309 1.0336 1.0360 1.0380 1.0399 1.0417 1.0432 1.0446 1.0458 1.0469 1.0480 1.0489 1.0499 1.0508 1.0516 1.0523 1.0530 1.0538 1.0544 1.0550 1
[Pg 119]
The temperature, pressure and other properties of steam for varying amounts of vacuum and the pressure above
vacuum corresponding to each inch of reading of the vacuum gauge are given in Table 20 .
TABLE 20
( t sup − t sat ) = degrees of superheat.
The specific heat of superheated steam will be taken up later.
Table 19 gives factors of evaporation for saturated steam boiler trials to cover a large range of conditions. Except
for the most refined work, intermediate values may be determined by interpolation.
Steam gauges indicate the pressure above the atmosphere. As has been pointed out, the atmospheric pressure
changes according to the altitude and the variation in the barometer. Hence, calculations involving the properties of
steam are based on absolute pressures, which are equal to the gauge pressure plus the atmospheric pressure in
pounds to the square inch. This latter is generally assumed to be 14.7 pounds per square inch at sea level, but for
other levels it must be determined from the barometric reading at that place.
Vacuum gauges indicate the difference, expressed in inches of mercury, between atmospheric pressure and the
pressure within the vessel to which the gauge is attached. For approximate purposes, 2.04 inches height of mercury
may be considered equal to a pressure of one pound per square inch at the ordinary temperatures at which mercury
gauges are used. Hence for any reading of the vacuum gauge in inches, G, the absolute pressure for any barometer
reading in inches, B, will be (B - G) ÷ 2.04. If the barometer is 30 inches measured at ordinary temperatures and
not corrected to 32 degrees Fahrenheit and the vacuum gauge 24 inches, the absolute pressure will be (30 - 24) ÷
2.04 = 2.9 pounds per square inch.
[Pg 118]
TABLE 19
FACTORS OF EVAPORATION
CALCULATED FROM MARKS AND DAVIS TABLES
Feed
Temp- Steam Pressure by Gauge
erature
Degrees
Fahren- 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240
heit
32 1.2143 1.2170 1.2194 1.2215 1.2233 1.2233 1.2265 1.2280 1.2292 1.2304 1.2314 1.2323 1.2333 1.2342 1.2350 1.2357 1.2364 1.2372 1.2378 1.2384 1
40 1.2060 1.2087 1.2111 1.2131 1.2150 1.2168 1.2181 1.2196 1.2209 1.2221 1.2231 1.2241 1.2250 1.2259 1.2267 1.2274 1.2282 1.2289 1.2295 1.2301 1
50 1.1957 1.1984 1.2008 1.2028 1.2047 1.2065 1.2079 1.2093 1.2106 1.2117 1.2128 1.2137 1.2147 1.2156 1.2164 1.2171 1.2178 1.2186 1.2192 1.2198 1
60 1.1854 1.1881 1.1905 1.1925 1.1944 1.1961 1.1976 1.1990 1.2003 1.2014 1.2025 1.2034 1.2044 1.2053 1.2061 1.2068 1.2075 1.2083 1.2089 1.2095 1
70 1.1750 1.1778 1.1802 1.1822 1.1841 1.1859 1.1873 1.1887 1.1900 1.1911 1.1922 1.1931 1.1941 1.1950 1.1958 1.1965 1.1972 1.1980 1.1986 1.1992 1
80 1.1649 1.1675 1.1699 1.1720 1.1738 1.1756 1.1770 1.1785 1.1797 1.1809 1.1819 1.1828 1.1838 1.1847 1.1855 1.1863 1.1869 1.1877 1.1883 1.1889 1
90 1.1545 1.1572 1.1596 1.1617 1.1636 1.1653 1.1668 1.1682 1.1695 1.1706 1.1717 1.1725 1.1735 1.1744 1.1750 1.1760 1.1766 1.1774 1.1780 1.1786 1
100 1.1443 1.1470 1.1493 1.1514 1.1533 1.1550 1.1565 1.1579 1.1592 1.1603 1.1614 1.1623 1.1633 1.1642 1.1650 1.1657 1.1664 1.1671 1.1678 1.1684 1
110 1.1340 1.1367 1.1391 1.1411 1.1430 1.1448 1.1462 1.1477 1.1489 1.1500 1.1511 1.1520 1.1530 1.1539 1.1547 1.1554 1.1562 1.1569 1.1575 1.1581 1
120 1.1237 1.1264 1.1288 1.1309 1.1327 1.1345 1.1359 1.1374 1.1386 1.1398 1.1408 1.1418 1.1427 1.1436 1.1444 1.1452 1.1459 1.1466 1.1472 1.1478 1
130 1.1134 1.1161 1.1185 1.1206 1.1225 1.1242 1.1257 1.1271 1.1284 1.1295 1.1305 1.1315 1.1324 1.1333 1.1341 1.1349 1.1356 1.1363 1.1369 1.1375 1
140 1.1031 1.1058 1.1082 1.1103 1.1122 1.1139 1.1154 1.1168 1.1181 1.1192 1.1203 1.1212 1.1221 1.1230 1.1239 1.1246 1.1253 1.1260 1.1266 1.1272 1
150 1.0928 1.0955 1.0979 1.1000 1.1019 1.1036 1.1051 1.1065 1.1078 1.1089 1.1099 1.1109 1.1118 1.1127 1.1136 1.1143 1.1150 1.1157 1.1163 1.1169 1
160 1.0825 1.0852 1.0876 1.0897 1.0916 1.0933 1.0948 1.0962 1.0975 1.0986 1.0997 1.1006 1.1015 1.1024 1.1033 1.1040 1.1047 1.1054 1.1060 1.1066 1
170 1.0722 1.0749 1.0773 1.0794 1.0813 1.0830 1.0845 1.0859 1.0872 1.0883 1.0893 1.0903 1.0912 1.0921 1.0930 1.0937 1.0944 1.0951 1.0957 1.0963 1
180 1.0619 1.0646 1.0670 1.0691 1.0709 1.0727 1.0741 1.0756 1.0768 1.0780 1.0790 1.0800 1.0809 1.0818 1.0826 1.0834 1.0841 1.0848 1.0854 1.0860 1
190 1.0516 1.0543 1.0567 1.0587 1.0606 1.0624 1.0638 1.0653 1.0665 1.0676 1.0687 1.0696 1.0706 1.0715 1.0723 1.0730 1.0737 1.0745 1.0751 1.0757 1
200 1.0412 1.0439 1.0463 1.0484 1.0503 1.0520 1.0535 1.0549 1.0562 1.0573 1.0584 1.0593 1.0602 1.0611 1.0620 1.0627 1.0634 1.0641 1.0647 1.0653 1
210 1.0309 1.0336 1.0360 1.0380 1.0399 1.0417 1.0432 1.0446 1.0458 1.0469 1.0480 1.0489 1.0499 1.0508 1.0516 1.0523 1.0530 1.0538 1.0544 1.0550 1
[Pg 119]
The temperature, pressure and other properties of steam for varying amounts of vacuum and the pressure above
vacuum corresponding to each inch of reading of the vacuum gauge are given in Table 20 .
TABLE 20
Page 163
PROPERTIES OF SATURATED STEAM FOR VARYING AMOUNTS OF VACUUM
CALCULATED FROM MARKS AND DAVIS TABLE
Absolute Temperature Heat of the Liquid Latent Heat Total Heat Density or Weight
Vacuum
Pressure Degrees Above 32 Degrees Above 32 Degrees Above 32 Degrees per Cubic Foot
Ins. Hg.
Pounds Fahrenheit B. t. u. B. t. u. B. t. u. Pounds
29.5 .207 54.1 22.18 1061.0 1083.2 0.000678
29 .452 76.6 44.64 1048.7 1093.3 0.001415
28.5 .698 90.1 58.09 1041.1 1099.2 0.002137
28 .944 99.9 67.87 1035.6 1103.5 0.002843
27 1.44 112.5 80.4 1028.6 1109.0 0.00421
26 1.93 124.5 92.3 1022.0 1114.3 0.00577
25 2.42 132.6 100.5 1017.3 1117.8 0.00689
24 2.91 140.1 108.0 1013.1 1121.1 0.00821
22 3.89 151.7 119.6 1006.4 1126.0 0.01078
20 4.87 161.1 128.9 1001.0 1129.9 0.01331
18 5.86 168.9 136.8 996.4 1133.2 0.01581
16 6.84 175.8 143.6 992.4 1136.0 0.01827
14 7.82 181.8 149.7 988.8 1138.5 0.02070
12 8.80 187.2 155.1 985.6 1140.7 0.02312
10 9.79 192.2 160.1 982.6 1142.7 0.02554
5 12.24 202.9 170.8 976.0 1146.8 0.03148
From the steam tables , the condensed Table 21 of the properties of steam at different pressures may be
constructed. From such a table there may be drawn the following conclusions.
TABLE 21 As the pressure and temperature increase, the latent heat
decreases. This decrease, however, is less rapid than the
VARIATION IN PROPERTIES OF corresponding increase in the heat of the liquid and hence the
SATURATED STEAM WITH PRESSURE total heat increases with an increase in the pressure and
Pressure Temperature Heat of Latent Total temperature. The percentage increase in the total heat is small,
Pounds Degrees Liquid Heat Heat being 0.5, 3.1, and 4.7 per cent for 20, 100, and 300 pounds
Absolute Fahrenheit B. t. u. B. t. u. B. t. u. absolute pressure respectively above the total heat in one pound
14.7 212.0 180.0 970.4 1150.4 of steam at 14.7 pounds absolute. The temperatures, on the
20.0 228.0 196.1 960.0 1156.2 other hand, increase at the rates of 7.5, 54.6, and 96.9 per cent.
The efficiency of a perfect steam engine is proportional to the
100.0 327.8 298.3 888.0 1186.3
expression ( t - t 1 )/ t in which t and t 1 are the absolute
300.0 417.5 392.7 811.3 1204.1 temperatures of the saturated steam at admission and exhaust
respectively. While actual engines only approximate the ideal
engine in efficiency, yet they follow the same general law. Since the exhaust temperature cannot be lowered
beyond present practice, it follows that the only available method of increasing the efficiency is by an increase in
the temperature of the steam at admission. How this may be [Pg 120] accomplished by an increase of pressure is
clearly shown, for the increase of fuel necessary to increase the pressure is negligible, as shown by the total heat,
while the increase in economy, due to the higher pressure, will result directly from the rapid increase of the
corresponding temperature.
TABLE 22
HEAT UNITS PER POUND AND WEIGHT PER CUBIC FOOT OF WATER
BETWEEN 32 DEGREES FAHRENHEIT AND 340 DEGREES FAHRENHEIT
Temp- Temp- Temp- Temp-
Heat Weight Heat Weight Heat Weight Heat Weight
erature erature erature erature
Units per Units per Units per Units per
Degrees Degrees Degrees Degrees
per Cubic per Cubic per Cubic per Cubic
Fahren- Fahren- Fahren- Fahren-
Pound Foot Pound Foot Pound Foot Pound Foot
heit heit heit heit
CALCULATED FROM MARKS AND DAVIS TABLE
Absolute Temperature Heat of the Liquid Latent Heat Total Heat Density or Weight
Vacuum
Pressure Degrees Above 32 Degrees Above 32 Degrees Above 32 Degrees per Cubic Foot
Ins. Hg.
Pounds Fahrenheit B. t. u. B. t. u. B. t. u. Pounds
29.5 .207 54.1 22.18 1061.0 1083.2 0.000678
29 .452 76.6 44.64 1048.7 1093.3 0.001415
28.5 .698 90.1 58.09 1041.1 1099.2 0.002137
28 .944 99.9 67.87 1035.6 1103.5 0.002843
27 1.44 112.5 80.4 1028.6 1109.0 0.00421
26 1.93 124.5 92.3 1022.0 1114.3 0.00577
25 2.42 132.6 100.5 1017.3 1117.8 0.00689
24 2.91 140.1 108.0 1013.1 1121.1 0.00821
22 3.89 151.7 119.6 1006.4 1126.0 0.01078
20 4.87 161.1 128.9 1001.0 1129.9 0.01331
18 5.86 168.9 136.8 996.4 1133.2 0.01581
16 6.84 175.8 143.6 992.4 1136.0 0.01827
14 7.82 181.8 149.7 988.8 1138.5 0.02070
12 8.80 187.2 155.1 985.6 1140.7 0.02312
10 9.79 192.2 160.1 982.6 1142.7 0.02554
5 12.24 202.9 170.8 976.0 1146.8 0.03148
From the steam tables , the condensed Table 21 of the properties of steam at different pressures may be
constructed. From such a table there may be drawn the following conclusions.
TABLE 21 As the pressure and temperature increase, the latent heat
decreases. This decrease, however, is less rapid than the
VARIATION IN PROPERTIES OF corresponding increase in the heat of the liquid and hence the
SATURATED STEAM WITH PRESSURE total heat increases with an increase in the pressure and
Pressure Temperature Heat of Latent Total temperature. The percentage increase in the total heat is small,
Pounds Degrees Liquid Heat Heat being 0.5, 3.1, and 4.7 per cent for 20, 100, and 300 pounds
Absolute Fahrenheit B. t. u. B. t. u. B. t. u. absolute pressure respectively above the total heat in one pound
14.7 212.0 180.0 970.4 1150.4 of steam at 14.7 pounds absolute. The temperatures, on the
20.0 228.0 196.1 960.0 1156.2 other hand, increase at the rates of 7.5, 54.6, and 96.9 per cent.
The efficiency of a perfect steam engine is proportional to the
100.0 327.8 298.3 888.0 1186.3
expression ( t - t 1 )/ t in which t and t 1 are the absolute
300.0 417.5 392.7 811.3 1204.1 temperatures of the saturated steam at admission and exhaust
respectively. While actual engines only approximate the ideal
engine in efficiency, yet they follow the same general law. Since the exhaust temperature cannot be lowered
beyond present practice, it follows that the only available method of increasing the efficiency is by an increase in
the temperature of the steam at admission. How this may be [Pg 120] accomplished by an increase of pressure is
clearly shown, for the increase of fuel necessary to increase the pressure is negligible, as shown by the total heat,
while the increase in economy, due to the higher pressure, will result directly from the rapid increase of the
corresponding temperature.
TABLE 22
HEAT UNITS PER POUND AND WEIGHT PER CUBIC FOOT OF WATER
BETWEEN 32 DEGREES FAHRENHEIT AND 340 DEGREES FAHRENHEIT
Temp- Temp- Temp- Temp-
Heat Weight Heat Weight Heat Weight Heat Weight
erature erature erature erature
Units per Units per Units per Units per
Degrees Degrees Degrees Degrees
per Cubic per Cubic per Cubic per Cubic
Fahren- Fahren- Fahren- Fahren-
Pound Foot Pound Foot Pound Foot Pound Foot
heit heit heit heit
Page 164
32 0.00 62.42 89 57.00 62.13 146 113.86 61.27 203 170.95 60.05
33 1.01 62.42 90 58.00 62.12 147 114.86 61.25 204 171.96 60.02
34 2.01 62.42 91 59.00 62.11 148 115.86 61.24 205 172.96 60.00
35 3.02 62.43 92 60.00 62.09 149 116.86 61.22 206 173.97 59.98
36 4.03 62.43 93 60.99 62.08 150 117.86 61.20 207 174.97 59.95
37 5.04 62.43 94 61.99 62.07 151 118.86 61.18 208 175.98 59.93
38 6.04 62.43 95 62.99 62.06 152 119.86 61.16 209 176.98 59.90
39 7.05 62.43 96 63.98 62.05 153 120.86 61.14 210 177.99 59.88
40 8.05 62.43 97 64.98 62.04 154 121.86 61.12 211 178.99 59.85
41 9.05 62.43 98 65.98 62.03 155 122.86 61.10 212 180.00 59.83
42 10.06 62.43 99 66.97 62.02 156 123.86 61.08 213 181.0 59.80
43 11.06 62.43 100 67.97 62.00 157 124.86 61.06 214 182.0 59.78
44 12.06 62.43 101 68.97 61.99 158 125.86 61.04 215 183.0 59.75
45 13.07 62.42 102 69.96 61.98 159 126.86 61.02 216 184.0 59.73
46 14.07 62.42 103 70.96 61.97 160 127.86 61.00 217 185.0 59.70
47 15.07 62.42 104 71.96 61.95 161 128.86 60.98 218 186.1 59.68
48 16.07 62.42 105 72.95 61.94 162 129.86 60.96 219 187.1 59.65
49 17.08 62.42 106 73.95 61.93 163 130.86 60.94 220 188.1 59.63
50 18.08 62.42 107 74.95 61.91 164 131.86 60.92 221 189.1 59.60
Temp- Temp- Temp- Temp-
Heat Weight Heat Weight Heat Weight Heat Weight
erature erature erature erature
Units per Units per Units per Units per
Degrees Degrees Degrees Degrees
per Cubic per Cubic per Cubic per Cubic
Fahren- Fahren- Fahren- Fahren-
Pound Foot Pound Foot Pound Foot Pound Foot
heit heit heit heit
51 19.08 62.41 108 75.95 61.90 165 132.86 60.90 222 190.1 59.58
52 20.08 62.41 109 76.94 61.88 166 133.86 60.88 223 191.1 59.55
53 21.08 62.41 110 77.94 61.86 167 134.86 60.86 224 192.1 59.53
54 22.08 62.40 111 78.94 61.85 168 135.86 60.84 225 193.1 59.50
55 23.08 62.40 112 79.93 61.83 169 136.86 60.82 226 194.1 59.48
56 24.08 62.39 113 80.93 61.82 170 137.87 60.80 227 195.2 59.45
57 25.08 62.39 114 81.93 61.80 171 138.87 60.78 228 196.2 59.42
58 26.08 62.38 115 82.92 61.79 172 139.87 60.76 229 197.2 59.40
59 27.08 62.37 116 83.92 61.77 173 140.87 60.73 230 198.2 59.37
60 28.08 62.37 117 84.92 61.75 174 141.87 60.71 231 199.2 59.34
61 29.08 62.36 118 85.92 61.74 175 142.87 60.69 232 200.2 59.32
62 30.08 62.36 119 86.91 61.72 176 143.87 60.67 233 201.2 59.29
63 31.07 62.35 120 87.91 61.71 177 144.88 60.65 234 202.2 59.27
64 32.07 62.35 121 88.91 61.69 178 145.88 60.62 235 203.2 59.24
65 33.07 62.34 122 89.91 61.68 179 146.88 60.60 236 204.2 59.21
66 34.07 62.33 123 90.90 61.66 180 147.88 60.58 237 205.3 59.19
67 35.07 62.33 124 91.90 61.65 181 148.88 60.56 238 206.3 59.16
68 36.07 62.32 125 92.90 61.63 182 149.89 60.53 239 207.3 59.14
69 37.06 62.31 126 93.90 61.61 183 150.89 60.51 240 208.3 59.11
Temp- Temp- Temp- Temp-
Heat Weight Heat Weight Heat Weight Heat Weight
erature erature erature erature
Units per Units per Units per Units per
Degrees Degrees Degrees Degrees
per Cubic per Cubic per Cubic per Cubic
Fahren- Fahren- Fahren- Fahren-
Pound Foot Pound Foot Pound Foot Pound Foot
heit heit heit heit
70 38.06 62.30 127 94.89 61.59 184 151.89 60.49 241 209.3 59.08
71 39.06 62.30 128 95.89 61.58 185 152.89 60.47 242 210.3 59.05
72 40.05 62.29 129 96.89 61.56 186 153.89 60.45 243 211.4 59.03
73 41.05 62.28 130 97.89 61.55 187 154.90 60.42 244 212.4 59.00
33 1.01 62.42 90 58.00 62.12 147 114.86 61.25 204 171.96 60.02
34 2.01 62.42 91 59.00 62.11 148 115.86 61.24 205 172.96 60.00
35 3.02 62.43 92 60.00 62.09 149 116.86 61.22 206 173.97 59.98
36 4.03 62.43 93 60.99 62.08 150 117.86 61.20 207 174.97 59.95
37 5.04 62.43 94 61.99 62.07 151 118.86 61.18 208 175.98 59.93
38 6.04 62.43 95 62.99 62.06 152 119.86 61.16 209 176.98 59.90
39 7.05 62.43 96 63.98 62.05 153 120.86 61.14 210 177.99 59.88
40 8.05 62.43 97 64.98 62.04 154 121.86 61.12 211 178.99 59.85
41 9.05 62.43 98 65.98 62.03 155 122.86 61.10 212 180.00 59.83
42 10.06 62.43 99 66.97 62.02 156 123.86 61.08 213 181.0 59.80
43 11.06 62.43 100 67.97 62.00 157 124.86 61.06 214 182.0 59.78
44 12.06 62.43 101 68.97 61.99 158 125.86 61.04 215 183.0 59.75
45 13.07 62.42 102 69.96 61.98 159 126.86 61.02 216 184.0 59.73
46 14.07 62.42 103 70.96 61.97 160 127.86 61.00 217 185.0 59.70
47 15.07 62.42 104 71.96 61.95 161 128.86 60.98 218 186.1 59.68
48 16.07 62.42 105 72.95 61.94 162 129.86 60.96 219 187.1 59.65
49 17.08 62.42 106 73.95 61.93 163 130.86 60.94 220 188.1 59.63
50 18.08 62.42 107 74.95 61.91 164 131.86 60.92 221 189.1 59.60
Temp- Temp- Temp- Temp-
Heat Weight Heat Weight Heat Weight Heat Weight
erature erature erature erature
Units per Units per Units per Units per
Degrees Degrees Degrees Degrees
per Cubic per Cubic per Cubic per Cubic
Fahren- Fahren- Fahren- Fahren-
Pound Foot Pound Foot Pound Foot Pound Foot
heit heit heit heit
51 19.08 62.41 108 75.95 61.90 165 132.86 60.90 222 190.1 59.58
52 20.08 62.41 109 76.94 61.88 166 133.86 60.88 223 191.1 59.55
53 21.08 62.41 110 77.94 61.86 167 134.86 60.86 224 192.1 59.53
54 22.08 62.40 111 78.94 61.85 168 135.86 60.84 225 193.1 59.50
55 23.08 62.40 112 79.93 61.83 169 136.86 60.82 226 194.1 59.48
56 24.08 62.39 113 80.93 61.82 170 137.87 60.80 227 195.2 59.45
57 25.08 62.39 114 81.93 61.80 171 138.87 60.78 228 196.2 59.42
58 26.08 62.38 115 82.92 61.79 172 139.87 60.76 229 197.2 59.40
59 27.08 62.37 116 83.92 61.77 173 140.87 60.73 230 198.2 59.37
60 28.08 62.37 117 84.92 61.75 174 141.87 60.71 231 199.2 59.34
61 29.08 62.36 118 85.92 61.74 175 142.87 60.69 232 200.2 59.32
62 30.08 62.36 119 86.91 61.72 176 143.87 60.67 233 201.2 59.29
63 31.07 62.35 120 87.91 61.71 177 144.88 60.65 234 202.2 59.27
64 32.07 62.35 121 88.91 61.69 178 145.88 60.62 235 203.2 59.24
65 33.07 62.34 122 89.91 61.68 179 146.88 60.60 236 204.2 59.21
66 34.07 62.33 123 90.90 61.66 180 147.88 60.58 237 205.3 59.19
67 35.07 62.33 124 91.90 61.65 181 148.88 60.56 238 206.3 59.16
68 36.07 62.32 125 92.90 61.63 182 149.89 60.53 239 207.3 59.14
69 37.06 62.31 126 93.90 61.61 183 150.89 60.51 240 208.3 59.11
Temp- Temp- Temp- Temp-
Heat Weight Heat Weight Heat Weight Heat Weight
erature erature erature erature
Units per Units per Units per Units per
Degrees Degrees Degrees Degrees
per Cubic per Cubic per Cubic per Cubic
Fahren- Fahren- Fahren- Fahren-
Pound Foot Pound Foot Pound Foot Pound Foot
heit heit heit heit
70 38.06 62.30 127 94.89 61.59 184 151.89 60.49 241 209.3 59.08
71 39.06 62.30 128 95.89 61.58 185 152.89 60.47 242 210.3 59.05
72 40.05 62.29 129 96.89 61.56 186 153.89 60.45 243 211.4 59.03
73 41.05 62.28 130 97.89 61.55 187 154.90 60.42 244 212.4 59.00
Page 165
74 42.05 62.27 131 98.89 61.53 188 155.90 60.40 245 213.4 58.97
75 42.05 62.26 132 99.88 61.52 189 156.90 60.38 246 214.4 58.94
76 44.04 62.26 133 100.88 61.50 190 157.91 60.36 247 215.4 58.91
77 45.04 62.25 134 101.88 61.49 191 158.91 60.33 248 216.4 58.89
78 46.04 62.24 135 102.88 61.47 192 159.91 60.31 249 217.4 58.86
79 47.04 62.23 136 103.88 61.45 193 160.91 60.29 250 218.5 58.83
80 48.03 62.22 137 104.87 61.43 194 161.92 60.27 260 228.6 58.55
81 49.03 62.21 138 105.87 61.41 195 162.92 60.24 270 238.8 58.26
82 50.03 62.20 139 106.87 61.40 196 163.92 60.22 280 249.0 57.96
83 51.02 62.19 140 107.87 61.38 197 164.93 60.19 290 259.3 57.65
84 52.02 62.18 141 108.87 61.36 198 165.93 60.17 300 269.6 57.33
85 53.02 62.17 142 109.87 61.34 199 166.94 60.15 310 279.9 57.00
86 54.01 62.16 143 110.87 61.33 200 167.94 60.12 320 290.2 56.66
87 55.01 62.15 144 111.87 61.31 201 168.94 60.10 330 300.6 56.30
88 56.01 62.14 145 112.86 61.29 202 169.95 60.07 340 311.0 55.94
[Pg 121]
The gain due to superheat cannot be predicted from the formula for the efficiency of a perfect steam engine given
on page 119 . This formula is not applicable in cases where superheat is present since only a relatively small
amount of the heat in the steam is imparted at the maximum or superheated temperature.
The advantage of the use of high pressure steam may be also indicated by considering the question from the aspect
of volume. With an increase of pressure comes a decrease in volume, thus one pound of saturated steam at 100
pounds absolute pressure occupies 4.43 cubic feet, while at 200 pounds pressure it occupies 2.29 cubic feet. If
then, in separate cylinders of the same dimensions, one pound of steam at 100 pounds absolute pressure and one
pound at 200 pounds absolute pressure enter and are allowed to expand to the full volume of each cylinder, the
high-pressure steam, having more room and a greater range for expansion than the low-pressure steam, will thus
do more work. This increase in the amount of work, as was the increase in temperature, is large relative to the
additional fuel required as indicated by the total heat. In general, it may be stated that the fuel required to impart a
given amount of heat to a boiler is practically independent of the steam pressure, since the temperature of the fire
is so high as compared with the steam temperature that a variation in the steam temperature does not produce an
appreciable effect.
The formulae for the algebraic expression of the relation between saturated steam pressures, temperatures and
steam volumes have been up to the present time empirical. These relations have, however, been determined by
experiment and, from the experimental data, tables have been computed which render unnecessary the use of
empirical formulae. Such formulae may be found in any standard work of thermo-dynamics. The following tables
cover all practical cases.
Table 22 gives the heat units contained in water above 32 degrees Fahrenheit at different temperatures.
Table 23 gives the properties of saturated steam for various pressures.
Table 24 gives the properties of superheated steam at various pressures and temperatures.
These tables are based on those computed by Lionel S. Marks and Harvey N. Davis, these being generally
accepted as being the most correct.
[Pg 122]
TABLE 23
PROPERTIES OF SATURATED STEAM REPRODUCED BY PERMISSION FROM
MARKS AND DAVIS “STEAM TABLES AND DIAGRAMS”
(Copyright, 1909, by Longmans, Green & Co.)
75 42.05 62.26 132 99.88 61.52 189 156.90 60.38 246 214.4 58.94
76 44.04 62.26 133 100.88 61.50 190 157.91 60.36 247 215.4 58.91
77 45.04 62.25 134 101.88 61.49 191 158.91 60.33 248 216.4 58.89
78 46.04 62.24 135 102.88 61.47 192 159.91 60.31 249 217.4 58.86
79 47.04 62.23 136 103.88 61.45 193 160.91 60.29 250 218.5 58.83
80 48.03 62.22 137 104.87 61.43 194 161.92 60.27 260 228.6 58.55
81 49.03 62.21 138 105.87 61.41 195 162.92 60.24 270 238.8 58.26
82 50.03 62.20 139 106.87 61.40 196 163.92 60.22 280 249.0 57.96
83 51.02 62.19 140 107.87 61.38 197 164.93 60.19 290 259.3 57.65
84 52.02 62.18 141 108.87 61.36 198 165.93 60.17 300 269.6 57.33
85 53.02 62.17 142 109.87 61.34 199 166.94 60.15 310 279.9 57.00
86 54.01 62.16 143 110.87 61.33 200 167.94 60.12 320 290.2 56.66
87 55.01 62.15 144 111.87 61.31 201 168.94 60.10 330 300.6 56.30
88 56.01 62.14 145 112.86 61.29 202 169.95 60.07 340 311.0 55.94
[Pg 121]
The gain due to superheat cannot be predicted from the formula for the efficiency of a perfect steam engine given
on page 119 . This formula is not applicable in cases where superheat is present since only a relatively small
amount of the heat in the steam is imparted at the maximum or superheated temperature.
The advantage of the use of high pressure steam may be also indicated by considering the question from the aspect
of volume. With an increase of pressure comes a decrease in volume, thus one pound of saturated steam at 100
pounds absolute pressure occupies 4.43 cubic feet, while at 200 pounds pressure it occupies 2.29 cubic feet. If
then, in separate cylinders of the same dimensions, one pound of steam at 100 pounds absolute pressure and one
pound at 200 pounds absolute pressure enter and are allowed to expand to the full volume of each cylinder, the
high-pressure steam, having more room and a greater range for expansion than the low-pressure steam, will thus
do more work. This increase in the amount of work, as was the increase in temperature, is large relative to the
additional fuel required as indicated by the total heat. In general, it may be stated that the fuel required to impart a
given amount of heat to a boiler is practically independent of the steam pressure, since the temperature of the fire
is so high as compared with the steam temperature that a variation in the steam temperature does not produce an
appreciable effect.
The formulae for the algebraic expression of the relation between saturated steam pressures, temperatures and
steam volumes have been up to the present time empirical. These relations have, however, been determined by
experiment and, from the experimental data, tables have been computed which render unnecessary the use of
empirical formulae. Such formulae may be found in any standard work of thermo-dynamics. The following tables
cover all practical cases.
Table 22 gives the heat units contained in water above 32 degrees Fahrenheit at different temperatures.
Table 23 gives the properties of saturated steam for various pressures.
Table 24 gives the properties of superheated steam at various pressures and temperatures.
These tables are based on those computed by Lionel S. Marks and Harvey N. Davis, these being generally
accepted as being the most correct.
[Pg 122]
TABLE 23
PROPERTIES OF SATURATED STEAM REPRODUCED BY PERMISSION FROM
MARKS AND DAVIS “STEAM TABLES AND DIAGRAMS”
(Copyright, 1909, by Longmans, Green & Co.)
Page 166
Pressure, Temperature Specific Volume Heat of the Latent Heat of Total Heat of
Pounds Absolute Degrees F. Cu. Ft. per Pound Liquid, B. t. u. Evap., B. t. u. Steam, B. t. u.
1 101.83 333.0 69.8 1034.6 1104.4
2 126.15 173.5 94.0 1021.0 1115.0
3 141.52 118.5 109.4 1012.3 1121.6
4 153.01 90.5 120.9 1005.7 1126.5
5 162.28 73.33 130.1 1000.3 1130.5
6 170.06 61.89 137.9 995.8 1133.7
7 176.85 53.56 144.7 991.8 1136.5
8 182.86 47.27 150.8 988.2 1139.0
9 188.27 42.36 156.2 985.0 1141.1
10 193.22 38.38 161.1 982.0 1143.1
11 197.75 35.10 165.7 979.2 1144.9
12 201.96 32.36 169.9 976.6 1146.5
13 205.87 30.03 173.8 974.2 1148.0
14 209.55 28.02 177.5 971.9 1149.4
15 213.0 26.27 181.0 969.7 1150.7
16 216.3 24.79 184.4 967.6 1152.0
17 219.4 23.38 187.5 965.6 1153.1
18 222.4 22.16 190.5 963.7 1154.2
19 225.2 21.07 193.4 961.8 1155.2
20 228.0 20.08 196.1 960.0 1156.2
22 233.1 18.37 201.3 956.7 1158.0
24 237.8 16.93 206.1 953.5 1159.6
26 242.2 15.72 210.6 950.6 1161.2
28 246.4 14.67 214.8 947.8 1162.6
30 250.3 13.74 218.8 945.1 1163.9
32 254.1 12.93 222.6 942.5 1165.1
34 257.6 12.22 226.2 940.1 1166.3
36 261.0 11.58 229.6 937.7 1167.3
38 264.2 11.01 232.9 935.5 1168.4
40 267.3 10.49 236.1 933.3 1169.4
42 270.2 10.02 239.1 931.2 1170.3
44 273.1 9.59 242.0 929.2 1171.2
46 275.8 9.20 244.8 927.2 1172.0
48 278.5 8.84 247.5 925.3 1172.8
50 281.0 8.51 250.1 923.5 1173.6
52 283.5 8.20 252.6 921.7 1174.3
Pressure, Temperature Specific Volume Heat of the Latent Heat of Total Heat of
Pounds Absolute Degrees F. Cu. Ft. per Pound Liquid, B. t. u. Evap., B. t. u. Steam, B. t. u.
54 285.9 7.91 255.1 919.9 1175.0
56 288.2 7.65 257.5 918.2 1175.7
58 290.5 7.40 259.8 916.5 1176.4
60 292.7 7.17 262.1 914.9 1177.0
62 294.9 6.95 264.3 913.3 1177.6
64 297.0 6.75 266.4 911.8 1178.2
66 299.0 6.56 268.5 910.2 1178.8
68 301.0 6.38 270.6 908.7 1179.3
70 302.9 6.20 272.6 907.2 1179.8 [Pg 123]
72 304.8 6.04 274.5 905.8 1180.4
74 306.7 5.89 276.5 904.4 1180.9
Pounds Absolute Degrees F. Cu. Ft. per Pound Liquid, B. t. u. Evap., B. t. u. Steam, B. t. u.
1 101.83 333.0 69.8 1034.6 1104.4
2 126.15 173.5 94.0 1021.0 1115.0
3 141.52 118.5 109.4 1012.3 1121.6
4 153.01 90.5 120.9 1005.7 1126.5
5 162.28 73.33 130.1 1000.3 1130.5
6 170.06 61.89 137.9 995.8 1133.7
7 176.85 53.56 144.7 991.8 1136.5
8 182.86 47.27 150.8 988.2 1139.0
9 188.27 42.36 156.2 985.0 1141.1
10 193.22 38.38 161.1 982.0 1143.1
11 197.75 35.10 165.7 979.2 1144.9
12 201.96 32.36 169.9 976.6 1146.5
13 205.87 30.03 173.8 974.2 1148.0
14 209.55 28.02 177.5 971.9 1149.4
15 213.0 26.27 181.0 969.7 1150.7
16 216.3 24.79 184.4 967.6 1152.0
17 219.4 23.38 187.5 965.6 1153.1
18 222.4 22.16 190.5 963.7 1154.2
19 225.2 21.07 193.4 961.8 1155.2
20 228.0 20.08 196.1 960.0 1156.2
22 233.1 18.37 201.3 956.7 1158.0
24 237.8 16.93 206.1 953.5 1159.6
26 242.2 15.72 210.6 950.6 1161.2
28 246.4 14.67 214.8 947.8 1162.6
30 250.3 13.74 218.8 945.1 1163.9
32 254.1 12.93 222.6 942.5 1165.1
34 257.6 12.22 226.2 940.1 1166.3
36 261.0 11.58 229.6 937.7 1167.3
38 264.2 11.01 232.9 935.5 1168.4
40 267.3 10.49 236.1 933.3 1169.4
42 270.2 10.02 239.1 931.2 1170.3
44 273.1 9.59 242.0 929.2 1171.2
46 275.8 9.20 244.8 927.2 1172.0
48 278.5 8.84 247.5 925.3 1172.8
50 281.0 8.51 250.1 923.5 1173.6
52 283.5 8.20 252.6 921.7 1174.3
Pressure, Temperature Specific Volume Heat of the Latent Heat of Total Heat of
Pounds Absolute Degrees F. Cu. Ft. per Pound Liquid, B. t. u. Evap., B. t. u. Steam, B. t. u.
54 285.9 7.91 255.1 919.9 1175.0
56 288.2 7.65 257.5 918.2 1175.7
58 290.5 7.40 259.8 916.5 1176.4
60 292.7 7.17 262.1 914.9 1177.0
62 294.9 6.95 264.3 913.3 1177.6
64 297.0 6.75 266.4 911.8 1178.2
66 299.0 6.56 268.5 910.2 1178.8
68 301.0 6.38 270.6 908.7 1179.3
70 302.9 6.20 272.6 907.2 1179.8 [Pg 123]
72 304.8 6.04 274.5 905.8 1180.4
74 306.7 5.89 276.5 904.4 1180.9
Page 167
76 308.5 5.74 278.3 903.0 1181.4
78 310.3 5.60 280.2 901.7 1181.8
80 312.0 5.47 282.0 900.3 1182.3
82 313.8 5.34 283.8 899.0 1182.8
84 315.4 5.22 285.5 897.7 1183.2
86 317.1 5.10 287.2 896.4 1183.6
88 318.7 5.00 288.9 895.2 1184.0
90 320.3 4.89 290.5 893.9 1184.4
92 321.8 4.79 292.1 892.7 1184.8
94 323.4 4.69 293.7 891.5 1185.2
96 324.9 4.60 295.3 890.3 1185.6
98 326.4 4.51 296.8 889.2 1186.0
100 327.8 4.429 298.3 888.0 1186.3
105 331.4 4.230 302.0 885.2 1187.2
110 334.8 4.047 305.5 882.5 1188.0
115 338.1 3.880 309.0 879.8 1188.8
120 341.3 3.726 312.3 877.2 1189.6
125 344.4 3.583 315.5 874.7 1190.3
130 347.4 3.452 318.6 872.3 1191.0
135 350.3 3.331 321.7 869.9 1191.6
140 353.1 3.219 324.6 867.6 1192.2
145 355.8 3.112 327.4 865.4 1192.8
150 358.5 3.012 330.2 863.2 1193.4
155 361.0 2.920 332.9 861.0 1194.0
160 363.6 2.834 335.6 858.8 1194.5
Pressure, Temperature Specific Volume Heat of the Latent Heat of Total Heat of
Pounds Absolute Degrees F. Cu. Ft. per Pound Liquid, B. t. u. Evap., B. t. u. Steam, B. t. u.
165 366.0 2.753 338.2 856.8 1195.0
170 368.5 2.675 340.7 854.7 1195.4
175 370.8 2.602 343.2 852.7 1195.9
180 373.1 2.533 345.6 850.8 1196.4
185 375.4 2.468 348.0 848.8 1196.8
190 377.6 2.406 350.4 846.9 1197.3
195 379.8 2.346 352.7 845.0 1197.7
200 381.9 2.290 354.9 843.2 1198.1
205 384.0 2.237 357.1 841.4 1198.5
210 386.0 2.187 359.2 839.6 1198.8
215 388.0 2.138 361.4 837.9 1199.2
220 389.9 2.091 363.4 836.2 1199.6
225 391.9 2.046 365.5 834.4 1199.9
230 393.8 2.004 367.5 832.8 1200.2
235 395.6 1.964 369.4 831.1 1200.6
240 397.4 1.924 371.4 829.5 1200.9
245 399.3 1.887 373.3 827.9 1201.2
250 401.1 1.850 375.2 826.3 1201.5 [Pg 124]
78 310.3 5.60 280.2 901.7 1181.8
80 312.0 5.47 282.0 900.3 1182.3
82 313.8 5.34 283.8 899.0 1182.8
84 315.4 5.22 285.5 897.7 1183.2
86 317.1 5.10 287.2 896.4 1183.6
88 318.7 5.00 288.9 895.2 1184.0
90 320.3 4.89 290.5 893.9 1184.4
92 321.8 4.79 292.1 892.7 1184.8
94 323.4 4.69 293.7 891.5 1185.2
96 324.9 4.60 295.3 890.3 1185.6
98 326.4 4.51 296.8 889.2 1186.0
100 327.8 4.429 298.3 888.0 1186.3
105 331.4 4.230 302.0 885.2 1187.2
110 334.8 4.047 305.5 882.5 1188.0
115 338.1 3.880 309.0 879.8 1188.8
120 341.3 3.726 312.3 877.2 1189.6
125 344.4 3.583 315.5 874.7 1190.3
130 347.4 3.452 318.6 872.3 1191.0
135 350.3 3.331 321.7 869.9 1191.6
140 353.1 3.219 324.6 867.6 1192.2
145 355.8 3.112 327.4 865.4 1192.8
150 358.5 3.012 330.2 863.2 1193.4
155 361.0 2.920 332.9 861.0 1194.0
160 363.6 2.834 335.6 858.8 1194.5
Pressure, Temperature Specific Volume Heat of the Latent Heat of Total Heat of
Pounds Absolute Degrees F. Cu. Ft. per Pound Liquid, B. t. u. Evap., B. t. u. Steam, B. t. u.
165 366.0 2.753 338.2 856.8 1195.0
170 368.5 2.675 340.7 854.7 1195.4
175 370.8 2.602 343.2 852.7 1195.9
180 373.1 2.533 345.6 850.8 1196.4
185 375.4 2.468 348.0 848.8 1196.8
190 377.6 2.406 350.4 846.9 1197.3
195 379.8 2.346 352.7 845.0 1197.7
200 381.9 2.290 354.9 843.2 1198.1
205 384.0 2.237 357.1 841.4 1198.5
210 386.0 2.187 359.2 839.6 1198.8
215 388.0 2.138 361.4 837.9 1199.2
220 389.9 2.091 363.4 836.2 1199.6
225 391.9 2.046 365.5 834.4 1199.9
230 393.8 2.004 367.5 832.8 1200.2
235 395.6 1.964 369.4 831.1 1200.6
240 397.4 1.924 371.4 829.5 1200.9
245 399.3 1.887 373.3 827.9 1201.2
250 401.1 1.850 375.2 826.3 1201.5 [Pg 124]
Page 168
Portion of 6100 Horse-power Installation of Babcock & Wilcox Boilers Equipped with Babcock & Wilcox
Chain Grate Stokers at the Campbell Street Plant of the Louisville Railway Co., Louisville, Ky. This
Company Operates a Total of 14,000 Horse Power of Babcock & Wilcox Boilers
[Pg 125]
TABLE 24
PROPERTIES OF SATURATED STEAM REPRODUCED BY
PERMISSION FROM
MARKS AND DAVIS “STEAM TABLES AND DIAGRAMS”
(Copyright, 1909, by Longmans, Green & Co.)
Degrees of Superheat
Pressure
Saturated
Pounds 50 100 150 200 250 300
Steam
Absolute
t 162.3 212.3 262.3 312.3 362.3 412.3 462.3
5v 73.3 79.7 85.7 91.8 97.8 103.8 109.8
h 1130.5 1153.5 1176.4 1199.5 1222.5 1245.6 1268.7
t 193.2 243.2 293.2 343.2 393.2 443.2 493.2
10 v 38.4 41.5 44.6 47.7 50.7 53.7 56.7
h 1143.1 1166.3 1189.5 1212.7 1236.0 1259.3 1282.5
t 213.0 263.0 313.0 363.0 413.0 463.0 513.0
15 v 26.27 28.40 30.46 32.50 34.53 36.56 38.58
h 1150.7 1174.2 1197.6 1221.0 1244.4 1267.7 1291.1
t 228.0 278.0 328.0 378.0 428.0 478.0 528.0
20 v 20.08 21.69 23.25 24.80 26.33 27.85 29.37
h 1156.2 1179.9 1203.5 1227.1 1250.6 1274.1 1297.6
t 240.1 290.1 340.1 390.1 440.1 490.1 540.1
25 v 16.30 17.60 18.86 20.10 21.32 22.55 23.77
h 1160.4 1184.4 1208.2 1231.9 1255.6 1279.2 1302.8
t 250.4 300.4 350.4 400.4 450.4 500.4 550.4
30 v 13.74 14.83 15.89 16.93 17.97 18.99 20.00
h 1163.9 1188.1 1212.1 1236.0 1259.7 1283.4 1307.1
Chain Grate Stokers at the Campbell Street Plant of the Louisville Railway Co., Louisville, Ky. This
Company Operates a Total of 14,000 Horse Power of Babcock & Wilcox Boilers
[Pg 125]
TABLE 24
PROPERTIES OF SATURATED STEAM REPRODUCED BY
PERMISSION FROM
MARKS AND DAVIS “STEAM TABLES AND DIAGRAMS”
(Copyright, 1909, by Longmans, Green & Co.)
Degrees of Superheat
Pressure
Saturated
Pounds 50 100 150 200 250 300
Steam
Absolute
t 162.3 212.3 262.3 312.3 362.3 412.3 462.3
5v 73.3 79.7 85.7 91.8 97.8 103.8 109.8
h 1130.5 1153.5 1176.4 1199.5 1222.5 1245.6 1268.7
t 193.2 243.2 293.2 343.2 393.2 443.2 493.2
10 v 38.4 41.5 44.6 47.7 50.7 53.7 56.7
h 1143.1 1166.3 1189.5 1212.7 1236.0 1259.3 1282.5
t 213.0 263.0 313.0 363.0 413.0 463.0 513.0
15 v 26.27 28.40 30.46 32.50 34.53 36.56 38.58
h 1150.7 1174.2 1197.6 1221.0 1244.4 1267.7 1291.1
t 228.0 278.0 328.0 378.0 428.0 478.0 528.0
20 v 20.08 21.69 23.25 24.80 26.33 27.85 29.37
h 1156.2 1179.9 1203.5 1227.1 1250.6 1274.1 1297.6
t 240.1 290.1 340.1 390.1 440.1 490.1 540.1
25 v 16.30 17.60 18.86 20.10 21.32 22.55 23.77
h 1160.4 1184.4 1208.2 1231.9 1255.6 1279.2 1302.8
t 250.4 300.4 350.4 400.4 450.4 500.4 550.4
30 v 13.74 14.83 15.89 16.93 17.97 18.99 20.00
h 1163.9 1188.1 1212.1 1236.0 1259.7 1283.4 1307.1
Page 169
t 259.3 309.3 359.3 409.3 459.3 509.3 559.3
35 v 11.89 12.85 13.75 14.65 15.54 16.42 17.30
h 1166.8 1191.3 1215.4 1239.4 1263.3 1287.1 1310.8
t 267.3 317.3 367.3 417.3 467.3 517.3 567.3
40 v 10.49 11.33 12.13 12.93 13.70 14.48 15.25
h 1169.4 1194.0 1218.4 1242.4 1266.4 1290.3 1314.1
t 274.5 324.5 374.5 424.5 474.5 524.5 574.5
45 v 9.39 10.14 10.86 11.57 12.27 12.96 13.65
h 1171.6 1196.6 1221.0 1245.2 1269.3 1293.2 1317.0
t 281.0 331.0 381.0 431.0 481.0 531.0 581.0
50 v 8.51 9.19 9.84 10.48 11.11 11.74 12.36
h 1173.6 1198.8 1223.4 1247.7 1271.8 1295.8 1319.7
t 287.1 337.1 387.1 437.1 487.1 537.1 587.1
60 v 7.78 8.40 9.00 9.59 10.16 10.73 11.30
h 1175.4 1200.8 1225.6 1250.0 1274.2 1298.1 1322.0
Degrees of Superheat
Pressure
Saturated
Pounds 50 100 150 200 250 300
Steam
Absolute
t 292.7 342.7 392.7 442.7 492.7 542.7 592.7
60 v 7.17 7.75 8.30 8.84 9.36 9.89 10.41
h 1177.0 1202.6 1227.6 1252.1 1276.4 1300.4 1324.3
t 298.0 348.0 398.0 448.0 498.0 548.0 598.0
65 v 6.65 7.20 7.70 8.20 8.69 9.17 9.65
h 1178.5 1204.4 1229.5 1254.0 1278.4 1302.4 1326.4
t 302.9 352.9 402.9 452.9 502.9 552.9 602.9
70 v 6.20 6.71 7.18 7.65 8.11 8.56 9.01
h 1179.8 1205.9 1231.2 1255.8 1280.2 1304.3 1328.3
t 307.6 357.6 407.6 457.6 507.6 557.6 607.6
75 v 5.81 6.28 6.73 7.17 7.60 8.02 8.44
h 1181.1 1207.5 1232.8 1257.5 1282.0 1306.1 1330.1
t 312.0 362.0 412.0 462.0 512.0 562.0 612.0
80 v 5.47 5.92 6.34 6.75 7.17 7.56 7.95
h 1182.3 1208.8 1234.3 1259.0 1283.6 1307.8 1331.9
t 316.3 366.3 416.3 466.3 516.3 566.3 616.3
85 v 5.16 5.59 6.99 6.38 6.76 7.14 7.51
h 1183.4 1210.2 1235.8 1260.6 1285.2 1309.4 1333.5
t 320.3 370.3 420.3 470.3 520.3 570.3 620.3 [Pg 126]
90 v 4.89 5.29 5.67 6.04 6.40 6.76 7.11
h 1184.4 1211.4 1237.2 1262.0 1286.6 1310.8 1334.9
t 324.1 374.1 424.1 474.1 524.1 574.1 624.1
95 v 4.65 5.03 5.39 5.74 6.09 6.43 6.76
h 1185.4 1212.6 1238.4 1263.4 1288.1 1312.3 1336.4
t 327.8 377.8 427.8 477.8 527.8 577.8 627.8
100 v 4.43 4.79 5.14 5.47 5.80 6.12 6.44
h 1186.3 1213.8 1239.7 1264.7 1289.4 1313.6 1337.8
t 331.4 381.4 431.4 481.4 531.4 581.4 631.4
105 v 4.23 4.58 4.91 5.23 5.54 5.85 6.15
h 1187.2 1214.9 1240.8 1265.9 1290.6 1314.9 1339.1
t 334.8 384.8 434.8 484.8 534.8 584.8 634.8
110 v 4.05 4.38 4.70 5.01 5.31 5.61 5.90
h 1188.0 1215.9 1242.0 1267.1 1291.9 1316.2 1340.4
Degrees of Superheat
35 v 11.89 12.85 13.75 14.65 15.54 16.42 17.30
h 1166.8 1191.3 1215.4 1239.4 1263.3 1287.1 1310.8
t 267.3 317.3 367.3 417.3 467.3 517.3 567.3
40 v 10.49 11.33 12.13 12.93 13.70 14.48 15.25
h 1169.4 1194.0 1218.4 1242.4 1266.4 1290.3 1314.1
t 274.5 324.5 374.5 424.5 474.5 524.5 574.5
45 v 9.39 10.14 10.86 11.57 12.27 12.96 13.65
h 1171.6 1196.6 1221.0 1245.2 1269.3 1293.2 1317.0
t 281.0 331.0 381.0 431.0 481.0 531.0 581.0
50 v 8.51 9.19 9.84 10.48 11.11 11.74 12.36
h 1173.6 1198.8 1223.4 1247.7 1271.8 1295.8 1319.7
t 287.1 337.1 387.1 437.1 487.1 537.1 587.1
60 v 7.78 8.40 9.00 9.59 10.16 10.73 11.30
h 1175.4 1200.8 1225.6 1250.0 1274.2 1298.1 1322.0
Degrees of Superheat
Pressure
Saturated
Pounds 50 100 150 200 250 300
Steam
Absolute
t 292.7 342.7 392.7 442.7 492.7 542.7 592.7
60 v 7.17 7.75 8.30 8.84 9.36 9.89 10.41
h 1177.0 1202.6 1227.6 1252.1 1276.4 1300.4 1324.3
t 298.0 348.0 398.0 448.0 498.0 548.0 598.0
65 v 6.65 7.20 7.70 8.20 8.69 9.17 9.65
h 1178.5 1204.4 1229.5 1254.0 1278.4 1302.4 1326.4
t 302.9 352.9 402.9 452.9 502.9 552.9 602.9
70 v 6.20 6.71 7.18 7.65 8.11 8.56 9.01
h 1179.8 1205.9 1231.2 1255.8 1280.2 1304.3 1328.3
t 307.6 357.6 407.6 457.6 507.6 557.6 607.6
75 v 5.81 6.28 6.73 7.17 7.60 8.02 8.44
h 1181.1 1207.5 1232.8 1257.5 1282.0 1306.1 1330.1
t 312.0 362.0 412.0 462.0 512.0 562.0 612.0
80 v 5.47 5.92 6.34 6.75 7.17 7.56 7.95
h 1182.3 1208.8 1234.3 1259.0 1283.6 1307.8 1331.9
t 316.3 366.3 416.3 466.3 516.3 566.3 616.3
85 v 5.16 5.59 6.99 6.38 6.76 7.14 7.51
h 1183.4 1210.2 1235.8 1260.6 1285.2 1309.4 1333.5
t 320.3 370.3 420.3 470.3 520.3 570.3 620.3 [Pg 126]
90 v 4.89 5.29 5.67 6.04 6.40 6.76 7.11
h 1184.4 1211.4 1237.2 1262.0 1286.6 1310.8 1334.9
t 324.1 374.1 424.1 474.1 524.1 574.1 624.1
95 v 4.65 5.03 5.39 5.74 6.09 6.43 6.76
h 1185.4 1212.6 1238.4 1263.4 1288.1 1312.3 1336.4
t 327.8 377.8 427.8 477.8 527.8 577.8 627.8
100 v 4.43 4.79 5.14 5.47 5.80 6.12 6.44
h 1186.3 1213.8 1239.7 1264.7 1289.4 1313.6 1337.8
t 331.4 381.4 431.4 481.4 531.4 581.4 631.4
105 v 4.23 4.58 4.91 5.23 5.54 5.85 6.15
h 1187.2 1214.9 1240.8 1265.9 1290.6 1314.9 1339.1
t 334.8 384.8 434.8 484.8 534.8 584.8 634.8
110 v 4.05 4.38 4.70 5.01 5.31 5.61 5.90
h 1188.0 1215.9 1242.0 1267.1 1291.9 1316.2 1340.4
Degrees of Superheat
Page 170
Pressure
Saturated
Pounds 50 100 150 200 250 300
Steam
Absolute
t 338.1 388.1 438.1 488.1 538.1 588.1 638.1
115 v 3.88 4.20 4.51 4.81 5.09 5.38 5.66
h 1188.8 1216.9 1243.1 1268.2 1293.0 1317.3 1341.5
t 341.3 391.3 441.3 491.3 541.3 591.3 641.3
120 v 3.73 4.04 4.33 4.62 4.89 5.17 5.44
h 1189.6 1217.9 1244.1 1269.3 1294.1 1318.4 1342.7
t 344.4 394.4 444.4 494.4 544.4 594.4 644.4
125 v 3.58 3.88 4.17 4.45 4.71 4.97 5.23
h 1190.3 1218.8 1245.1 1270.4 1295.2 1319.5 1343.8
t 347.4 397.4 447.4 497.4 547.4 597.4 647.4
130 v 3.45 3.74 4.02 4.28 4.54 4.80 5.05
h 1191.0 1219.7 1246.1 1271.4 1296.2 1320.6 1344.9
t 350.3 400.3 450.3 500.3 550.3 600.3 650.3
135 v 3.33 3.61 3.88 4.14 4.38 4.63 4.87
h 1191.6 1220.6 1247.0 1272.3 1297.2 1321.6 1345.9
t 353.1 403.1 453.1 503.1 553.1 603.1 653.1
140 v 3.22 3.49 3.75 4.00 4.24 4.48 4.71
h 1192.2 1221.4 1248.0 1273.3 1298.2 1322.6 1346.9
t 355.8 405.8 455.8 505.8 555.8 605.8 655.8
145 v 3.12 3.38 3.63 3.87 4.10 4.33 4.56
h 1192.8 1222.2 1248.8 1274.2 1299.1 1323.6 1347.9
t 358.5 408.5 458.5 508.5 558.5 608.5 658.5
150 v 3.01 3.27 3.50 3.75 3.97 4.19 4.41
h 1193.4 1223.0 1249.6 1275.1 1300.0 1324.5 1348.8
t 361.0 411.0 461.0 511.0 561.0 611.0 661.0
155 v 2.92 3.17 3.41 3.63 3.85 4.06 4.28
h 1194.0 1223.6 1250.5 1276.0 1300.8 1325.3 1349.7
t 363.6 413.6 463.6 513.6 563.6 613.6 663.6
160 v 2.83 3.07 3.30 3.53 3.74 3.95 4.15
h 1194.5 1224.5 1251.3 1276.8 1301.7 1326.2 1350.6
t 366.0 416.0 466.0 516.0 566.0 616.0 666.0
165 v 2.75 2.99 3.21 3.43 3.64 3.84 4.04
h 1195.0 1225.2 1252.0 1277.6 1302.5 1327.1 1351.5
Degrees of Superheat
Pressure
Saturated
Pounds 50 100 150 200 250 300
Steam
Absolute
t 368.5 418.5 468.5 518.5 568.5 618.5 668.5
170 v 2.68 2.91 3.12 3.34 3.54 3.73 3.92
h 1195.4 1225.9 1252.8 1278.4 1303.3 1327.9 1352.3
t 370.8 420.8 470.8 520.8 570.8 620.8 670.8 [Pg 127]
175 v 2.60 2.83 3.04 3.24 3.44 3.63 3.82
h 1195.9 1226.6 1253.6 1279.1 1304.1 1328.7 1353.2
t 373.1 423.1 473.1 523.1 573.1 623.1 673.1
180 v 2.53 2.75 2.96 3.16 3.35 3.54 3.72
h 1196.4 1227.2 1254.3 1279.9 1304.8 1329.5 1353.9
t 375.4 425.4 475.4 525.4 575.4 625.4 675.4
185 v 2.47 2.68 2.89 3.08 3.27 3.45 3.63
h 1196.8 1227.9 1255.0 1280.6 1305.6 1330.2 1354.7
190 t 377.6 427.6 477.6 527.6 577.6 627.6 677.6
v 2.41 2.62 2.81 3.00 3.19 3.37 3.55
Saturated
Pounds 50 100 150 200 250 300
Steam
Absolute
t 338.1 388.1 438.1 488.1 538.1 588.1 638.1
115 v 3.88 4.20 4.51 4.81 5.09 5.38 5.66
h 1188.8 1216.9 1243.1 1268.2 1293.0 1317.3 1341.5
t 341.3 391.3 441.3 491.3 541.3 591.3 641.3
120 v 3.73 4.04 4.33 4.62 4.89 5.17 5.44
h 1189.6 1217.9 1244.1 1269.3 1294.1 1318.4 1342.7
t 344.4 394.4 444.4 494.4 544.4 594.4 644.4
125 v 3.58 3.88 4.17 4.45 4.71 4.97 5.23
h 1190.3 1218.8 1245.1 1270.4 1295.2 1319.5 1343.8
t 347.4 397.4 447.4 497.4 547.4 597.4 647.4
130 v 3.45 3.74 4.02 4.28 4.54 4.80 5.05
h 1191.0 1219.7 1246.1 1271.4 1296.2 1320.6 1344.9
t 350.3 400.3 450.3 500.3 550.3 600.3 650.3
135 v 3.33 3.61 3.88 4.14 4.38 4.63 4.87
h 1191.6 1220.6 1247.0 1272.3 1297.2 1321.6 1345.9
t 353.1 403.1 453.1 503.1 553.1 603.1 653.1
140 v 3.22 3.49 3.75 4.00 4.24 4.48 4.71
h 1192.2 1221.4 1248.0 1273.3 1298.2 1322.6 1346.9
t 355.8 405.8 455.8 505.8 555.8 605.8 655.8
145 v 3.12 3.38 3.63 3.87 4.10 4.33 4.56
h 1192.8 1222.2 1248.8 1274.2 1299.1 1323.6 1347.9
t 358.5 408.5 458.5 508.5 558.5 608.5 658.5
150 v 3.01 3.27 3.50 3.75 3.97 4.19 4.41
h 1193.4 1223.0 1249.6 1275.1 1300.0 1324.5 1348.8
t 361.0 411.0 461.0 511.0 561.0 611.0 661.0
155 v 2.92 3.17 3.41 3.63 3.85 4.06 4.28
h 1194.0 1223.6 1250.5 1276.0 1300.8 1325.3 1349.7
t 363.6 413.6 463.6 513.6 563.6 613.6 663.6
160 v 2.83 3.07 3.30 3.53 3.74 3.95 4.15
h 1194.5 1224.5 1251.3 1276.8 1301.7 1326.2 1350.6
t 366.0 416.0 466.0 516.0 566.0 616.0 666.0
165 v 2.75 2.99 3.21 3.43 3.64 3.84 4.04
h 1195.0 1225.2 1252.0 1277.6 1302.5 1327.1 1351.5
Degrees of Superheat
Pressure
Saturated
Pounds 50 100 150 200 250 300
Steam
Absolute
t 368.5 418.5 468.5 518.5 568.5 618.5 668.5
170 v 2.68 2.91 3.12 3.34 3.54 3.73 3.92
h 1195.4 1225.9 1252.8 1278.4 1303.3 1327.9 1352.3
t 370.8 420.8 470.8 520.8 570.8 620.8 670.8 [Pg 127]
175 v 2.60 2.83 3.04 3.24 3.44 3.63 3.82
h 1195.9 1226.6 1253.6 1279.1 1304.1 1328.7 1353.2
t 373.1 423.1 473.1 523.1 573.1 623.1 673.1
180 v 2.53 2.75 2.96 3.16 3.35 3.54 3.72
h 1196.4 1227.2 1254.3 1279.9 1304.8 1329.5 1353.9
t 375.4 425.4 475.4 525.4 575.4 625.4 675.4
185 v 2.47 2.68 2.89 3.08 3.27 3.45 3.63
h 1196.8 1227.9 1255.0 1280.6 1305.6 1330.2 1354.7
190 t 377.6 427.6 477.6 527.6 577.6 627.6 677.6
v 2.41 2.62 2.81 3.00 3.19 3.37 3.55
Page 171
h 1197.3 1228.6 1255.7 1281.3 1306.3 1330.9 1355.5
t 379.8 429.8 479.8 529.8 579.8 629.8 679.8
195 v 2.35 2.55 2.75 2.93 3.11 3.29 3.46
h 1197.7 1229.2 1256.4 1282.0 1307.0 1331.6 1356.2
t 381.9 431.9 481.9 531.9 581.9 631.9 681.9
200 v 2.29 2.49 2.68 2.86 3.04 3.21 3.38
h 1198.1 1229.8 1257.1 1282.6 1307.7 1332.4 1357.0
t 384.0 434.0 484.0 534.0 584.0 634.0 684.0
205 v 2.24 2.44 2.62 2.80 2.97 3.14 3.30
h 1198.5 1230.4 1257.7 1283.3 1308.3 1333.0 1357.7
t 386.0 436.0 486.0 536.0 586.0 636.0 686.0
210 v 2.19 2.38 2.56 2.74 2.91 3.07 3.23
h 1198.8 1231.0 1258.4 1284.0 1309.0 1333.7 1358.4
t 388.0 438.0 488.0 538.0 588.0 638.0 688.0
215 v 2.14 2.33 2.51 2.68 2.84 3.00 3.16
h 1199.2 1231.6 1259.0 1284.6 1309.7 1334.4 1359.1
t 389.9 439.9 489.9 539.9 589.9 639.9 689.9
220 v 2.09 2.28 2.45 2.62 2.78 2.94 3.10
h 1199.6 1232.2 1259.6 1285.2 1310.3 1335.1 1359.8
Degrees of Superheat
Pressure
Saturated
Pounds 50 100 150 200 250 300
Steam
Absolute
t 391.9 441.9 491.9 541.9 591.9 641.9 691.9
225 v 2.05 2.23 2.40 2.57 2.72 2.88 3.03
h 1199.9 1232.7 1260.2 1285.9 1310.9 1335.7 1360.3
t 393.8 443.8 493.8 543.8 593.8 643.8 693.8
230 v 2.00 2.18 2.35 2.51 2.67 2.82 2.97
h 1200.2 1233.2 1260.7 1286.5 1311.6 1336.3 1361.0
t 395.6 445.6 495.6 545.6 595.6 645.6 695.6
235 v 1.96 2.14 2.30 2.46 2.62 2.77 2.91
h 1200.6 1233.8 1261.4 1287.1 1312.2 1337.0 1361.7
t 397.4 447.4 497.4 547.4 597.4 647.4 697.4
240 v 1.92 2.09 2.26 2.42 2.57 2.71 2.85
h 1200.9 1234.3 1261.9 1287.6 1312.8 1337.6 1362.3
t 399.3 449.3 499.3 549.3 599.3 649.3 699.3
245 v 1.89 2.05 2.22 2.37 2.52 2.66 2.80
h 1201.2 1234.8 1262.5 1288.2 1313.3 1338.2 1362.9
t 401.0 451.0 501.0 551.0 601.0 651.0 701.0
250 v 1.85 2.02 2.17 2.33 2.47 2.61 2.75
h 1201.5 1235.4 1263.0 1288.8 1313.9 1338.8 1363.5
t 402.8 452.8 502.8 552.8 602.8 652.8 702.8
255 v 1.81 1.98 2.14 2.28 2.43 2.56 2.70
h 1201.8 1235.9 1263.6 1289.3 1314.5 1339.3 1364.1
t = Temperature, degrees Fahrenheit.
v = Specific volume, in cubic feet, per pound.
h = Total heat from water at 32 degrees, B. t. u.
[Pg 128]
t 379.8 429.8 479.8 529.8 579.8 629.8 679.8
195 v 2.35 2.55 2.75 2.93 3.11 3.29 3.46
h 1197.7 1229.2 1256.4 1282.0 1307.0 1331.6 1356.2
t 381.9 431.9 481.9 531.9 581.9 631.9 681.9
200 v 2.29 2.49 2.68 2.86 3.04 3.21 3.38
h 1198.1 1229.8 1257.1 1282.6 1307.7 1332.4 1357.0
t 384.0 434.0 484.0 534.0 584.0 634.0 684.0
205 v 2.24 2.44 2.62 2.80 2.97 3.14 3.30
h 1198.5 1230.4 1257.7 1283.3 1308.3 1333.0 1357.7
t 386.0 436.0 486.0 536.0 586.0 636.0 686.0
210 v 2.19 2.38 2.56 2.74 2.91 3.07 3.23
h 1198.8 1231.0 1258.4 1284.0 1309.0 1333.7 1358.4
t 388.0 438.0 488.0 538.0 588.0 638.0 688.0
215 v 2.14 2.33 2.51 2.68 2.84 3.00 3.16
h 1199.2 1231.6 1259.0 1284.6 1309.7 1334.4 1359.1
t 389.9 439.9 489.9 539.9 589.9 639.9 689.9
220 v 2.09 2.28 2.45 2.62 2.78 2.94 3.10
h 1199.6 1232.2 1259.6 1285.2 1310.3 1335.1 1359.8
Degrees of Superheat
Pressure
Saturated
Pounds 50 100 150 200 250 300
Steam
Absolute
t 391.9 441.9 491.9 541.9 591.9 641.9 691.9
225 v 2.05 2.23 2.40 2.57 2.72 2.88 3.03
h 1199.9 1232.7 1260.2 1285.9 1310.9 1335.7 1360.3
t 393.8 443.8 493.8 543.8 593.8 643.8 693.8
230 v 2.00 2.18 2.35 2.51 2.67 2.82 2.97
h 1200.2 1233.2 1260.7 1286.5 1311.6 1336.3 1361.0
t 395.6 445.6 495.6 545.6 595.6 645.6 695.6
235 v 1.96 2.14 2.30 2.46 2.62 2.77 2.91
h 1200.6 1233.8 1261.4 1287.1 1312.2 1337.0 1361.7
t 397.4 447.4 497.4 547.4 597.4 647.4 697.4
240 v 1.92 2.09 2.26 2.42 2.57 2.71 2.85
h 1200.9 1234.3 1261.9 1287.6 1312.8 1337.6 1362.3
t 399.3 449.3 499.3 549.3 599.3 649.3 699.3
245 v 1.89 2.05 2.22 2.37 2.52 2.66 2.80
h 1201.2 1234.8 1262.5 1288.2 1313.3 1338.2 1362.9
t 401.0 451.0 501.0 551.0 601.0 651.0 701.0
250 v 1.85 2.02 2.17 2.33 2.47 2.61 2.75
h 1201.5 1235.4 1263.0 1288.8 1313.9 1338.8 1363.5
t 402.8 452.8 502.8 552.8 602.8 652.8 702.8
255 v 1.81 1.98 2.14 2.28 2.43 2.56 2.70
h 1201.8 1235.9 1263.6 1289.3 1314.5 1339.3 1364.1
t = Temperature, degrees Fahrenheit.
v = Specific volume, in cubic feet, per pound.
h = Total heat from water at 32 degrees, B. t. u.
[Pg 128]
Page 172
Fig. 15. Graphic Method of Determining Moisture Contained in Steam from Calorimeter Readings
Page 173
[Pg 129]
Page 174
MOISTURE IN STEAM
The presence of moisture in steam causes a loss, not only in the practical
waste of the heat utilized to raise this moisture from the temperature of the
feed water to the temperature of the steam, but also through the increased
initial condensation in an engine cylinder and through friction and other
actions in a steam turbine. The presence of such moisture also interferes
with proper cylinder lubrication, causes a knocking in the engine and a
water hammer in the steam pipes. In steam turbines it will cause erosion of
the blades.
The percentage by weight of steam in a mixture of steam and water is called
the quality of the steam.
The apparatus used to determine the moisture content of steam is called a
calorimeter though since it may not measure the heat in the steam, the name
is not descriptive of the function of the apparatus. The first form used was
the “barrel calorimeter”, but the liability of error was so great that its use
was abandoned. Modern calorimeters are in general of either the throttling
or separator type.
Throttling Calorimeter—Fig. 14 shows a typical form of throttling
calorimeter. Steam is drawn from a vertical main through the sampling
nipple, passes around the first thermometer cup, then through a one-eighth
inch orifice in a disk between two flanges, and lastly around the second
thermometer cup and to the atmosphere. Thermometers are inserted in the
wells, which should be filled with mercury or heavy cylinder oil.
The instrument and all pipes and fittings leading to it should be thoroughly
insulated to diminish radiation losses. Care must be taken to prevent the
orifice from becoming choked with dirt and to see that no leaks occur. The
exhaust pipe should be short to prevent back pressure below the disk.
When steam passes through an orifice from a higher to a lower pressure, as
is the case with the throttling calorimeter, no external work has to be done
The presence of moisture in steam causes a loss, not only in the practical
waste of the heat utilized to raise this moisture from the temperature of the
feed water to the temperature of the steam, but also through the increased
initial condensation in an engine cylinder and through friction and other
actions in a steam turbine. The presence of such moisture also interferes
with proper cylinder lubrication, causes a knocking in the engine and a
water hammer in the steam pipes. In steam turbines it will cause erosion of
the blades.
The percentage by weight of steam in a mixture of steam and water is called
the quality of the steam.
The apparatus used to determine the moisture content of steam is called a
calorimeter though since it may not measure the heat in the steam, the name
is not descriptive of the function of the apparatus. The first form used was
the “barrel calorimeter”, but the liability of error was so great that its use
was abandoned. Modern calorimeters are in general of either the throttling
or separator type.
Throttling Calorimeter—Fig. 14 shows a typical form of throttling
calorimeter. Steam is drawn from a vertical main through the sampling
nipple, passes around the first thermometer cup, then through a one-eighth
inch orifice in a disk between two flanges, and lastly around the second
thermometer cup and to the atmosphere. Thermometers are inserted in the
wells, which should be filled with mercury or heavy cylinder oil.
The instrument and all pipes and fittings leading to it should be thoroughly
insulated to diminish radiation losses. Care must be taken to prevent the
orifice from becoming choked with dirt and to see that no leaks occur. The
exhaust pipe should be short to prevent back pressure below the disk.
When steam passes through an orifice from a higher to a lower pressure, as
is the case with the throttling calorimeter, no external work has to be done
Page 175
in overcoming a resistance. Hence,
if there is no loss from radiation, the
quantity of heat in the steam will be
exactly the same after passing the
orifice as before passing. If the
higher steam pressure is 160 pounds
gauge and the lower pressure that of
the atmosphere, the total heat in a
pound of dry steam at the former
pressure is 1195.9 B. t. u. and at the
latter pressure 1150.4 B. t. u., a
difference of 45.4 B. t. u. As this
Fig. 14. Throttling Calorimeter heat will still exist in the steam at
and Sampling Nozzle the lower pressure, since there is no
external work done, its effect must
be to superheat the steam. Assuming
the specific heat of superheated steam to be 0.47, each pound passing
through will be superheated 45.4⁄0.47 = 96.6 degrees. If, however, the steam
had contained one per cent of moisture, it would have contained less heat
units per pound than if it were dry. Since the latent heat of steam at 160
[Pg 130] pounds gauge pressure is 852.8 B. t. u., it follows that the one per
cent of moisture would have required 8.5 B. t. u. to evaporate it, leaving
only 45.4 - 8.5 = 36.9 B. t. u. available for superheating; hence, the
superheat would be 36.9⁄0.47 = 78.5 degrees, as against 96.6 degrees for dry
steam. In a similar manner, the degree of superheat for other percentages of
moisture may be determined. The action of the throttling calorimeter is
based upon the foregoing facts, as shown below.
Let H = total heat of one pound of steam at boiler pressure,
L = latent heat of steam at boiler pressure,
h = total heat of steam at reduced pressure after passing orifice,
t1 = temperature of saturated steam at the reduced pressure,
t2 temperature of steam after expanding through the orifice in the
=
disc,
0.47 = the specific heat of saturated steam at atmospheric pressure,
x = proportion by weight of moisture in steam.
if there is no loss from radiation, the
quantity of heat in the steam will be
exactly the same after passing the
orifice as before passing. If the
higher steam pressure is 160 pounds
gauge and the lower pressure that of
the atmosphere, the total heat in a
pound of dry steam at the former
pressure is 1195.9 B. t. u. and at the
latter pressure 1150.4 B. t. u., a
difference of 45.4 B. t. u. As this
Fig. 14. Throttling Calorimeter heat will still exist in the steam at
and Sampling Nozzle the lower pressure, since there is no
external work done, its effect must
be to superheat the steam. Assuming
the specific heat of superheated steam to be 0.47, each pound passing
through will be superheated 45.4⁄0.47 = 96.6 degrees. If, however, the steam
had contained one per cent of moisture, it would have contained less heat
units per pound than if it were dry. Since the latent heat of steam at 160
[Pg 130] pounds gauge pressure is 852.8 B. t. u., it follows that the one per
cent of moisture would have required 8.5 B. t. u. to evaporate it, leaving
only 45.4 - 8.5 = 36.9 B. t. u. available for superheating; hence, the
superheat would be 36.9⁄0.47 = 78.5 degrees, as against 96.6 degrees for dry
steam. In a similar manner, the degree of superheat for other percentages of
moisture may be determined. The action of the throttling calorimeter is
based upon the foregoing facts, as shown below.
Let H = total heat of one pound of steam at boiler pressure,
L = latent heat of steam at boiler pressure,
h = total heat of steam at reduced pressure after passing orifice,
t1 = temperature of saturated steam at the reduced pressure,
t2 temperature of steam after expanding through the orifice in the
=
disc,
0.47 = the specific heat of saturated steam at atmospheric pressure,
x = proportion by weight of moisture in steam.
Page 176
The difference in B. t. u. in a pound of steam at the boiler pressure and after
passing the orifice is the heat available for evaporating the moisture content
and superheating the steam. Therefore,
H - h = xL + 0.47(t2 - t1)
H - h - 0.47(t2 - t1)
or x = –––––––––––––––––––––––––––––––– (4)
L
Almost invariably the lower pressure is taken as that of the atmosphere.
Under such conditions, h = 1150.4 and t1 = 212 degrees. The formula thus
becomes:
H - 1150.4 - 0.47(t2 - 212)
x= –––––––––––––––––––––––––––––––––––––––––––– (5)
L
For practical work it is more convenient to dispense with the upper
thermometer in the calorimeter and to measure the pressure in the steam
main by an accurate steam pressure gauge.
A chart may be used for determining the value of x for approximate work
without the necessity for computation. Such a chart is shown in Fig. 15 and
its use is as follows: Assume a gauge pressure of 180 pounds and a
thermometer reading of 295 degrees. The intersection of the vertical line
from the scale of temperatures as shown by the calorimeter thermometer
and the horizontal line from the scale of gauge pressures will indicate
directly the per cent of moisture in the steam as read from the diagonal
scale. In the present instance, this per cent is 1.0.
Sources of Error in the Apparatus—A slight error may arise from the
value, 0.47, used as the specific heat of superheated steam at atmospheric
pressure. This value, however is very nearly correct and any error resulting
from its use will be negligible.
There is ordinarily a larger source of error due to the fact that the stem of
the thermometer is not heated to its full length, to an initial error in the
passing the orifice is the heat available for evaporating the moisture content
and superheating the steam. Therefore,
H - h = xL + 0.47(t2 - t1)
H - h - 0.47(t2 - t1)
or x = –––––––––––––––––––––––––––––––– (4)
L
Almost invariably the lower pressure is taken as that of the atmosphere.
Under such conditions, h = 1150.4 and t1 = 212 degrees. The formula thus
becomes:
H - 1150.4 - 0.47(t2 - 212)
x= –––––––––––––––––––––––––––––––––––––––––––– (5)
L
For practical work it is more convenient to dispense with the upper
thermometer in the calorimeter and to measure the pressure in the steam
main by an accurate steam pressure gauge.
A chart may be used for determining the value of x for approximate work
without the necessity for computation. Such a chart is shown in Fig. 15 and
its use is as follows: Assume a gauge pressure of 180 pounds and a
thermometer reading of 295 degrees. The intersection of the vertical line
from the scale of temperatures as shown by the calorimeter thermometer
and the horizontal line from the scale of gauge pressures will indicate
directly the per cent of moisture in the steam as read from the diagonal
scale. In the present instance, this per cent is 1.0.
Sources of Error in the Apparatus—A slight error may arise from the
value, 0.47, used as the specific heat of superheated steam at atmospheric
pressure. This value, however is very nearly correct and any error resulting
from its use will be negligible.
There is ordinarily a larger source of error due to the fact that the stem of
the thermometer is not heated to its full length, to an initial error in the
Page 177
thermometer and to radiation losses.
With an ordinary thermometer immersed in the well to the 100 degrees
mark, the error when registering 300 degrees would be about 3 degrees and
the true temperature be 303 degrees.[19]
The steam is evidently losing heat through radiation from the moment it
enters the sampling nipple. The heat available for evaporating moisture and
superheating [Pg 131] steam after it has passed through the orifice into the
lower pressure will be diminished by just the amount lost through radiation
and the value of t2, as shown by the calorimeter thermometer, will,
therefore, be lower than if there were no such loss. The method of
correcting for the thermometer and radiation error recommended by the
Power Test Committee of the American Society of Mechanical Engineers is
by referring the readings as found on the boiler trial to a “normal” reading
of the thermometer. This normal reading is the reading of the lower
calorimeter thermometer for dry saturated steam, and should be determined
by attaching the instrument to a horizontal steam pipe in such a way that the
sampling nozzle projects upward to near the top of the pipe, there being no
perforations in the nozzle and the steam taken only through its open upper
end. The test should be made with the steam in a quiescent state and with
the steam pressure maintained as nearly as possible at the pressure observed
in the main trial, the calorimeter thermometer to be the same as was used on
the trial or one exactly similar.
With a normal reading thus obtained for a pressure approximately the same
as existed in the trial, the true percentage of moisture in the steam, that is,
with the proper correction made for radiation, may be calculated as follows:
Let T denote the normal reading for the conditions existing in the trial. The
effect of radiation from the instrument as pointed out will be to lower the
temperature of the steam at the lower pressure. Let x1 represent the
proportion of water in the steam which will lower its temperature an
amount equal to the loss by radiation. Then,
x1 = H - h - 0.47(T - t1)
––––––––––––––––––––––––––––––
With an ordinary thermometer immersed in the well to the 100 degrees
mark, the error when registering 300 degrees would be about 3 degrees and
the true temperature be 303 degrees.[19]
The steam is evidently losing heat through radiation from the moment it
enters the sampling nipple. The heat available for evaporating moisture and
superheating [Pg 131] steam after it has passed through the orifice into the
lower pressure will be diminished by just the amount lost through radiation
and the value of t2, as shown by the calorimeter thermometer, will,
therefore, be lower than if there were no such loss. The method of
correcting for the thermometer and radiation error recommended by the
Power Test Committee of the American Society of Mechanical Engineers is
by referring the readings as found on the boiler trial to a “normal” reading
of the thermometer. This normal reading is the reading of the lower
calorimeter thermometer for dry saturated steam, and should be determined
by attaching the instrument to a horizontal steam pipe in such a way that the
sampling nozzle projects upward to near the top of the pipe, there being no
perforations in the nozzle and the steam taken only through its open upper
end. The test should be made with the steam in a quiescent state and with
the steam pressure maintained as nearly as possible at the pressure observed
in the main trial, the calorimeter thermometer to be the same as was used on
the trial or one exactly similar.
With a normal reading thus obtained for a pressure approximately the same
as existed in the trial, the true percentage of moisture in the steam, that is,
with the proper correction made for radiation, may be calculated as follows:
Let T denote the normal reading for the conditions existing in the trial. The
effect of radiation from the instrument as pointed out will be to lower the
temperature of the steam at the lower pressure. Let x1 represent the
proportion of water in the steam which will lower its temperature an
amount equal to the loss by radiation. Then,
x1 = H - h - 0.47(T - t1)
––––––––––––––––––––––––––––––
Page 178
L
This amount of moisture, x1 was not in the steam originally but is the result
of condensation in the instrument through radiation. Hence, the true amount
of moisture in the steam represented by X is the difference between the
amount as determined in the trial and that resulting from condensation, or,
X = x - x1
H - h - 0.47(t2 - t1) H - h - 0.47(T - t1)
X = ––––––––––––––––––––––––––––––– - –––––––––––––––––––––––––––––––
L L
0.47(T - t2)
X = –––––––––––––––––––– (6)
L
As T and t2 are taken with the same thermometer under the same set of
conditions, any error in the reading of the thermometers will be
approximately the same for the temperatures T and t2 and the above method
therefore corrects for both the radiation and thermometer errors. The
theoretical readings for dry steam, where there are no losses due to
radiation, are obtainable from formula (5) by letting x = 0 and solving for t2.
The difference between the theoretical reading and the normal reading for
no moisture will be the thermometer and radiation correction to be applied
in order that the correct reading of t2 may be obtained.
For any calorimeter within the range of its ordinary use, such a thermometer
and radiation correction taken from one normal reading is approximately
correct for any conditions with the same or a duplicate thermometer.
The percentage of moisture in the steam, corrected for thermometer error
and radiation and the correction to be applied to the particular calorimeter
used, would be [Pg 132] determined as follows: Assume a gauge pressure in
the trial to be 180 pounds and the thermometer reading to be 295 degrees. A
normal reading, taken in the manner described, gives a value of T = 303
degrees; then, the percentage of moisture corrected for thermometer error
and radiation is,
This amount of moisture, x1 was not in the steam originally but is the result
of condensation in the instrument through radiation. Hence, the true amount
of moisture in the steam represented by X is the difference between the
amount as determined in the trial and that resulting from condensation, or,
X = x - x1
H - h - 0.47(t2 - t1) H - h - 0.47(T - t1)
X = ––––––––––––––––––––––––––––––– - –––––––––––––––––––––––––––––––
L L
0.47(T - t2)
X = –––––––––––––––––––– (6)
L
As T and t2 are taken with the same thermometer under the same set of
conditions, any error in the reading of the thermometers will be
approximately the same for the temperatures T and t2 and the above method
therefore corrects for both the radiation and thermometer errors. The
theoretical readings for dry steam, where there are no losses due to
radiation, are obtainable from formula (5) by letting x = 0 and solving for t2.
The difference between the theoretical reading and the normal reading for
no moisture will be the thermometer and radiation correction to be applied
in order that the correct reading of t2 may be obtained.
For any calorimeter within the range of its ordinary use, such a thermometer
and radiation correction taken from one normal reading is approximately
correct for any conditions with the same or a duplicate thermometer.
The percentage of moisture in the steam, corrected for thermometer error
and radiation and the correction to be applied to the particular calorimeter
used, would be [Pg 132] determined as follows: Assume a gauge pressure in
the trial to be 180 pounds and the thermometer reading to be 295 degrees. A
normal reading, taken in the manner described, gives a value of T = 303
degrees; then, the percentage of moisture corrected for thermometer error
and radiation is,
Page 179
0.47(303 - 295)
x= ––––––––––––––––––––––––––
845.0
x = 0.45 per cent.
The theoretical reading for dry steam will be,
1197.7 - 1150.4 - 0.47(t2 - 212)
0= ––––––––––––––––––––––––––––––––––––––––––––––––––––
845.0
t2 = 313 degrees.
The thermometer and radiation correction to be applied to the instrument
used, therefore over the ordinary range of pressure is
Correction = 313 - 303 = 10 degrees
The chart may be used in the determination of the correct reading of
moisture percentage and the permanent radiation correction for the
instrument used without computation as follows: Assume the same trial
pressure, feed temperature and normal reading as above. If the normal
reading is found to be 303 degrees, the correction for thermometer and
radiation will be the theoretical reading for dry steam as found from the
chart, less this normal reading, or 10 degrees correction. The correct
temperature for the trial in question is, therefore, 305 degrees. The moisture
corresponding to this temperature and 180 pounds gauge pressure will be
found from the chart to be 0.45 per cent.
There are many forms of throttling calorimeter, all of which work upon the
same principle. The simplest one is probably that shown in Fig. 14. An
extremely convenient and compact design is shown in Fig. 16. This
calorimeter consists of two concentric metal cylinders screwed to a cap
containing a thermometer well. The steam pressure is measured by a gauge
placed in the supply pipe or other convenient location. Steam passes
through the orifice A and expands to atmospheric pressure, its temperature
at this pressure being measured by a thermometer placed in the cup C. To
prevent as far as possible radiation losses, the annular space between the
x= ––––––––––––––––––––––––––
845.0
x = 0.45 per cent.
The theoretical reading for dry steam will be,
1197.7 - 1150.4 - 0.47(t2 - 212)
0= ––––––––––––––––––––––––––––––––––––––––––––––––––––
845.0
t2 = 313 degrees.
The thermometer and radiation correction to be applied to the instrument
used, therefore over the ordinary range of pressure is
Correction = 313 - 303 = 10 degrees
The chart may be used in the determination of the correct reading of
moisture percentage and the permanent radiation correction for the
instrument used without computation as follows: Assume the same trial
pressure, feed temperature and normal reading as above. If the normal
reading is found to be 303 degrees, the correction for thermometer and
radiation will be the theoretical reading for dry steam as found from the
chart, less this normal reading, or 10 degrees correction. The correct
temperature for the trial in question is, therefore, 305 degrees. The moisture
corresponding to this temperature and 180 pounds gauge pressure will be
found from the chart to be 0.45 per cent.
There are many forms of throttling calorimeter, all of which work upon the
same principle. The simplest one is probably that shown in Fig. 14. An
extremely convenient and compact design is shown in Fig. 16. This
calorimeter consists of two concentric metal cylinders screwed to a cap
containing a thermometer well. The steam pressure is measured by a gauge
placed in the supply pipe or other convenient location. Steam passes
through the orifice A and expands to atmospheric pressure, its temperature
at this pressure being measured by a thermometer placed in the cup C. To
prevent as far as possible radiation losses, the annular space between the
Page 180
two cylinders is used as a jacket, steam
being supplied to this space through the
hole B.
The limits of moisture within which the
throttling calorimeter will work are, at
sea level, from 2.88 per cent at 50
pounds gauge pressure and 7.17 per cent
moisture at 250 pounds pressure.
Separating Calorimeter—The
separating calorimeter mechanically
separates the entrained water from the
steam and collects it in a reservoir, where
its amount is [Pg 133] either indicated by a
Fig. 16. Compact Throttling gauge glass or is drained off and
Calorimeter weighed. Fig. 17 shows a calorimeter of
this type. The steam passes out of the
calorimeter through an orifice of known
size so that its total amount can be calculated or it can be weighed. A gauge
is ordinarily provided with this type of calorimeter, which shows the
pressure in its inner chamber and the flow of steam for a given period, this
latter scale being graduated by trial.
The instrument, like a throttling calorimeter, should be well insulated to
prevent losses from radiation.
While theoretically the separating calorimeter is not limited in capacity, it is
well in cases where the percentage of moisture present in the steam is
known to be high, to attach a throttling calorimeter to its exhaust. This, in
effect, is the using of the separating calorimeter as a small separator
between the sampling nozzle and the throttling instrument, and is necessary
to insure the determination of the full percentage of moisture in the steam.
The sum of the percentages shown by the two instruments is the moisture
content of the steam.
The steam passing through a separating calorimeter may be calculated by
Napier’s formula, the size of the orifice being known. There are objections
being supplied to this space through the
hole B.
The limits of moisture within which the
throttling calorimeter will work are, at
sea level, from 2.88 per cent at 50
pounds gauge pressure and 7.17 per cent
moisture at 250 pounds pressure.
Separating Calorimeter—The
separating calorimeter mechanically
separates the entrained water from the
steam and collects it in a reservoir, where
its amount is [Pg 133] either indicated by a
Fig. 16. Compact Throttling gauge glass or is drained off and
Calorimeter weighed. Fig. 17 shows a calorimeter of
this type. The steam passes out of the
calorimeter through an orifice of known
size so that its total amount can be calculated or it can be weighed. A gauge
is ordinarily provided with this type of calorimeter, which shows the
pressure in its inner chamber and the flow of steam for a given period, this
latter scale being graduated by trial.
The instrument, like a throttling calorimeter, should be well insulated to
prevent losses from radiation.
While theoretically the separating calorimeter is not limited in capacity, it is
well in cases where the percentage of moisture present in the steam is
known to be high, to attach a throttling calorimeter to its exhaust. This, in
effect, is the using of the separating calorimeter as a small separator
between the sampling nozzle and the throttling instrument, and is necessary
to insure the determination of the full percentage of moisture in the steam.
The sum of the percentages shown by the two instruments is the moisture
content of the steam.
The steam passing through a separating calorimeter may be calculated by
Napier’s formula, the size of the orifice being known. There are objections
Page 181
to such a calculation, however, in
that it is difficult to accurately
determine the areas of such small
orifices. Further, small orifices have
a tendency to become partly closed
by sediment that may be carried by
the steam. The more accurate method
of determining the amount of steam
passing through the instrument is as
follows:
A hose should be attached to the
separator outlet leading to a vessel of
water on a platform scale graduated
to 1⁄100 of a pound. The steam outlet
should be connected to another
vessel of water resting on a second
scale. In each case, the weight of
each vessel and its contents should be
noted. When ready for an
Fig. 17. Separating Calorimeter
observation, the instrument should be
blown out thoroughly so that there
will be no water within the separator.
The separator drip should then be closed and the steam hose inserted into
the vessel of water at the same instant. When the separator has accumulated
a sufficient quantity of water, the valve of the instrument should be closed
and the hose removed from the vessel of water. The separator should be
emptied into the vessel on its scale. The final weight of each vessel and its
contents are to be noted and the differences between the final and original
weights will represent the weight of moisture collected by the separator and
the weight of steam from which the moisture has been taken. The
proportion of moisture can then be calculated from the following formula:
100 w
x = ––––––––––– (7)
W-w
that it is difficult to accurately
determine the areas of such small
orifices. Further, small orifices have
a tendency to become partly closed
by sediment that may be carried by
the steam. The more accurate method
of determining the amount of steam
passing through the instrument is as
follows:
A hose should be attached to the
separator outlet leading to a vessel of
water on a platform scale graduated
to 1⁄100 of a pound. The steam outlet
should be connected to another
vessel of water resting on a second
scale. In each case, the weight of
each vessel and its contents should be
noted. When ready for an
Fig. 17. Separating Calorimeter
observation, the instrument should be
blown out thoroughly so that there
will be no water within the separator.
The separator drip should then be closed and the steam hose inserted into
the vessel of water at the same instant. When the separator has accumulated
a sufficient quantity of water, the valve of the instrument should be closed
and the hose removed from the vessel of water. The separator should be
emptied into the vessel on its scale. The final weight of each vessel and its
contents are to be noted and the differences between the final and original
weights will represent the weight of moisture collected by the separator and
the weight of steam from which the moisture has been taken. The
proportion of moisture can then be calculated from the following formula:
100 w
x = ––––––––––– (7)
W-w
Page 182
Where x=
per cent moisture in steam,
[Pg 134]
W = weight of steam condensed,
w = weight of moisture as taken out by the separating
calorimeter.
Sampling Nipple—The principle source of error in steam calorimeter
determinations is the failure to obtain an average sample of the steam
delivered by the boiler and it is extremely doubtful whether such a sample
is ever obtained. The two governing features in the obtaining of such a
sample are the type of sampling nozzle used and its location.
The American Society of Mechanical Engineers recommends a sampling
nozzle made of one-half inch iron pipe closed at the inner end and the
interior portion perforated with not less than twenty one-eighth inch holes
equally distributed from end to end and preferably drilled in irregular or
spiral rows, with the first hole not less than one-half inch from the wall of
the pipe. Many engineers object to the use of a perforated sampling nipple
because it ordinarily indicates a higher percentage of moisture than is
actually present in the steam. This is due to the fact that if the perforations
come close to the inner surface of the pipe, the moisture, which in many
instances clings to this surface, will flow into the calorimeter and cause a
large error. Where a perforated nipple is used, in general it may be said that
the perforations should be at least one inch from the inner pipe surface.
A sampling nipple, open at the inner end and unperforated, undoubtedly
gives as accurate a measure as can be obtained of the moisture in the steam
passing that end. It would appear that a satisfactory method of obtaining an
average sample of the steam would result from the use of an open end
unperforated nipple passing through a stuffing box which would allow the
end to be placed at any point across the diameter of the steam pipe.
Incidental to a test of a 15,000 K. W. steam
engine turbine unit, Mr. H. G. Stott and Mr.
R. G. S. Pigott, finding no experimental data
bearing on the subject of low pressure steam
quality determinations, made a investigation
per cent moisture in steam,
[Pg 134]
W = weight of steam condensed,
w = weight of moisture as taken out by the separating
calorimeter.
Sampling Nipple—The principle source of error in steam calorimeter
determinations is the failure to obtain an average sample of the steam
delivered by the boiler and it is extremely doubtful whether such a sample
is ever obtained. The two governing features in the obtaining of such a
sample are the type of sampling nozzle used and its location.
The American Society of Mechanical Engineers recommends a sampling
nozzle made of one-half inch iron pipe closed at the inner end and the
interior portion perforated with not less than twenty one-eighth inch holes
equally distributed from end to end and preferably drilled in irregular or
spiral rows, with the first hole not less than one-half inch from the wall of
the pipe. Many engineers object to the use of a perforated sampling nipple
because it ordinarily indicates a higher percentage of moisture than is
actually present in the steam. This is due to the fact that if the perforations
come close to the inner surface of the pipe, the moisture, which in many
instances clings to this surface, will flow into the calorimeter and cause a
large error. Where a perforated nipple is used, in general it may be said that
the perforations should be at least one inch from the inner pipe surface.
A sampling nipple, open at the inner end and unperforated, undoubtedly
gives as accurate a measure as can be obtained of the moisture in the steam
passing that end. It would appear that a satisfactory method of obtaining an
average sample of the steam would result from the use of an open end
unperforated nipple passing through a stuffing box which would allow the
end to be placed at any point across the diameter of the steam pipe.
Incidental to a test of a 15,000 K. W. steam
engine turbine unit, Mr. H. G. Stott and Mr.
R. G. S. Pigott, finding no experimental data
bearing on the subject of low pressure steam
quality determinations, made a investigation
Page 183
Fig. 18. Stott and Pigott of the subject and the sampling nozzle
Sampling Nozzle illustrated in Fig. 18 was developed. In
speaking of sampling nozzles in the
determination of the moisture content of low
pressure steam, Mr. Pigott says, “the ordinary standard perforated pipe
sampler is absolutely worthless in giving a true sample and it is vital that
the sample be abstracted from the main without changing its direction or
velocity until it is safely within the sample pipe and entirely isolated from
the rest of the steam.”
It would appear that the nozzle illustrated is undoubtedly the best that has
been developed for use in the determination of the moisture content of
steam, not only in the case of low, but also in high pressure steam.
Location of Sampling Nozzle—The calorimeter should be located as near
as possible to the point from which the steam is taken and the sampling
nipple should be placed in a section of the main pipe near the boiler and
where there is no chance of moisture pocketing in the pipe. The American
Society of Mechanical Engineers recommends that a sampling nipple, of
which a description has been given, should be located in a vertical main,
rising from the boiler with its closed end extending nearly [Pg 135] across the
pipe. Where non-return valves are used, or where there are horizontal
connections leading from the boiler to a vertical outlet, water may collect at
the lower end of the uptake pipe and be blown upward in a spray which will
not be carried away by the steam owing to a lack of velocity. A sample
taken from the lower part of this pipe will show a greater amount of
moisture than a true sample. With goose-neck connections a small amount
of water may collect on the bottom of the pipe near the upper end where the
inclination is such that the tendency to flow backward is ordinarily
counterbalanced by the flow of steam forward over its surface; but when the
velocity momentarily decreases the water flows back to the lower end of the
goose-neck and increases the moisture at that point, making it an
undesirable location for sampling. In any case, it should be borne in mind
that with low velocities the tendency is for drops of entrained water to settle
to the bottom of the pipe, and to be temporarily broken up into spray
whenever an abrupt bend or other disturbance is met.
Sampling Nozzle illustrated in Fig. 18 was developed. In
speaking of sampling nozzles in the
determination of the moisture content of low
pressure steam, Mr. Pigott says, “the ordinary standard perforated pipe
sampler is absolutely worthless in giving a true sample and it is vital that
the sample be abstracted from the main without changing its direction or
velocity until it is safely within the sample pipe and entirely isolated from
the rest of the steam.”
It would appear that the nozzle illustrated is undoubtedly the best that has
been developed for use in the determination of the moisture content of
steam, not only in the case of low, but also in high pressure steam.
Location of Sampling Nozzle—The calorimeter should be located as near
as possible to the point from which the steam is taken and the sampling
nipple should be placed in a section of the main pipe near the boiler and
where there is no chance of moisture pocketing in the pipe. The American
Society of Mechanical Engineers recommends that a sampling nipple, of
which a description has been given, should be located in a vertical main,
rising from the boiler with its closed end extending nearly [Pg 135] across the
pipe. Where non-return valves are used, or where there are horizontal
connections leading from the boiler to a vertical outlet, water may collect at
the lower end of the uptake pipe and be blown upward in a spray which will
not be carried away by the steam owing to a lack of velocity. A sample
taken from the lower part of this pipe will show a greater amount of
moisture than a true sample. With goose-neck connections a small amount
of water may collect on the bottom of the pipe near the upper end where the
inclination is such that the tendency to flow backward is ordinarily
counterbalanced by the flow of steam forward over its surface; but when the
velocity momentarily decreases the water flows back to the lower end of the
goose-neck and increases the moisture at that point, making it an
undesirable location for sampling. In any case, it should be borne in mind
that with low velocities the tendency is for drops of entrained water to settle
to the bottom of the pipe, and to be temporarily broken up into spray
whenever an abrupt bend or other disturbance is met.
Page 184
Fig. 19. Illustrating the Manner in which Erroneous Calorimeter
Readings may be Obtained
due to Improper Location of Sampling Nozzle
Case 1—Horizontal pipe. Water flows at bottom. If perforations in nozzle are too near
bottom of pipe, water piles against nozzle, flows into calorimeter and gives false reading.
Case 2—If nozzle located too near junction of two horizontal runs, as at a, condensation
from vertical pipe which collects at this point will be thrown against the nozzle by the
velocity of the steam, resulting in a false reading. Nozzle should be located far enough
above junction to be removed from water kept in motion by the steam velocity, as at b.
Case 3—Condensation in bend will be held by velocity of the steam as shown. When
velocity is diminished during firing intervals and the like moisture flows back against
nozzle, a, and false reading is obtained. A true reading will be obtained at b provided
condensation is not blown over on nozzle. Case 4—Where non-return valve is placed
before a bend, condensation will collect on steam line side and water will be swept by
steam velocity against nozzle and false readings result.
Fig. 19 indicates certain locations of sampling nozzles from which
erroneous results will be obtained, the reasons being obvious from a study
of the cuts.
Before taking any calorimeter reading, steam should be allowed to flow
through the instrument freely until it is thoroughly heated. The method of
using a throttling calorimeter is evident from the description of the
instrument given and the principle upon which it works.
[Pg 136]
Readings may be Obtained
due to Improper Location of Sampling Nozzle
Case 1—Horizontal pipe. Water flows at bottom. If perforations in nozzle are too near
bottom of pipe, water piles against nozzle, flows into calorimeter and gives false reading.
Case 2—If nozzle located too near junction of two horizontal runs, as at a, condensation
from vertical pipe which collects at this point will be thrown against the nozzle by the
velocity of the steam, resulting in a false reading. Nozzle should be located far enough
above junction to be removed from water kept in motion by the steam velocity, as at b.
Case 3—Condensation in bend will be held by velocity of the steam as shown. When
velocity is diminished during firing intervals and the like moisture flows back against
nozzle, a, and false reading is obtained. A true reading will be obtained at b provided
condensation is not blown over on nozzle. Case 4—Where non-return valve is placed
before a bend, condensation will collect on steam line side and water will be swept by
steam velocity against nozzle and false readings result.
Fig. 19 indicates certain locations of sampling nozzles from which
erroneous results will be obtained, the reasons being obvious from a study
of the cuts.
Before taking any calorimeter reading, steam should be allowed to flow
through the instrument freely until it is thoroughly heated. The method of
using a throttling calorimeter is evident from the description of the
instrument given and the principle upon which it works.
[Pg 136]
Page 185
Babcock & Wilcox Superheater
FOOTNOTES
[19] See Stem Correction, page 80.
FOOTNOTES
[19] See Stem Correction, page 80.
Page 186
[Pg 137]
Page 187
SUPERHEATED STEAM
Superheated steam, as already stated, is steam the temperature of which exceeds that of
saturated steam at the same pressure. It is produced by the addition of heat to saturated steam
which has been removed from contact with the water from which it was generated. The
properties of superheated steam approximate those of a perfect gas rather than of a vapor.
Saturated steam cannot be superheated when it is in contact with water which is also heated,
neither can superheated steam condense without first being reduced to the temperature of
saturated steam. Just so long as its temperature is above that of saturated steam at a
corresponding pressure it is superheated, and before condensation can take place that
superheat must first be lost through radiation or some other means. Table 24[20] gives such
properties of superheated steam for varying pressures as are necessary for use in ordinary
engineering practice.
Specific Heat of Superheated Steam—The specific heat of superheated steam at atmospheric
pressure and near saturation point was determined by Regnault, in 1862, who gives it the
value of 0.48. Regnault’s value was based on four series of experiments, all at atmospheric
pressure and with about the same temperature range, the maximum of which was 231.1
degrees centigrade. For fifty years after Regnault’s determination, this value was accepted
and applied to higher pressures and temperatures as well as to the range of his experiments.
More recent investigations have shown that the specific heat is not a constant and varies with
both pressure and the temperature. A number of experiments have been made by various
investigators and, up to the present, the most reliable appear to be those of Knoblauch and
Jacob. Messrs. Marks and Davis have used the values as determined by Knoblauch and Jacob
with slight modifications. The first consists in a varying of the curves at low pressures close
to saturation because of thermodynamic evidence and in view of Regnault’s determination at
atmospheric pressure. The second modification is at high degrees of superheat to follow
Holborn’s and Henning’s curve, which is accepted as authentic.
For the sake of convenience, the mean specific heat of superheated steam at various
pressures and temperatures is given in tabulated form in Table 25. These values have been
calculated from Marks and Davis Steam Tables by deducting from the total heat of one
pound of steam at any pressure for any degree of superheat the total heat of one pound of
saturated steam at the same pressure and dividing the difference by the number of degrees of
superheat and, therefore, represent the average specific heat starting from that at saturation to
the value at the particular pressure and temperature.[21] Expressed as a formula this
calculation is represented by
Hsup - Hsat
Sp. Ht. = –––––––––––––––––––– (8)
Ssup - Ssat
Where Hsup = total heat of one pound of superheated steam at any pressure and temperature,
Superheated steam, as already stated, is steam the temperature of which exceeds that of
saturated steam at the same pressure. It is produced by the addition of heat to saturated steam
which has been removed from contact with the water from which it was generated. The
properties of superheated steam approximate those of a perfect gas rather than of a vapor.
Saturated steam cannot be superheated when it is in contact with water which is also heated,
neither can superheated steam condense without first being reduced to the temperature of
saturated steam. Just so long as its temperature is above that of saturated steam at a
corresponding pressure it is superheated, and before condensation can take place that
superheat must first be lost through radiation or some other means. Table 24[20] gives such
properties of superheated steam for varying pressures as are necessary for use in ordinary
engineering practice.
Specific Heat of Superheated Steam—The specific heat of superheated steam at atmospheric
pressure and near saturation point was determined by Regnault, in 1862, who gives it the
value of 0.48. Regnault’s value was based on four series of experiments, all at atmospheric
pressure and with about the same temperature range, the maximum of which was 231.1
degrees centigrade. For fifty years after Regnault’s determination, this value was accepted
and applied to higher pressures and temperatures as well as to the range of his experiments.
More recent investigations have shown that the specific heat is not a constant and varies with
both pressure and the temperature. A number of experiments have been made by various
investigators and, up to the present, the most reliable appear to be those of Knoblauch and
Jacob. Messrs. Marks and Davis have used the values as determined by Knoblauch and Jacob
with slight modifications. The first consists in a varying of the curves at low pressures close
to saturation because of thermodynamic evidence and in view of Regnault’s determination at
atmospheric pressure. The second modification is at high degrees of superheat to follow
Holborn’s and Henning’s curve, which is accepted as authentic.
For the sake of convenience, the mean specific heat of superheated steam at various
pressures and temperatures is given in tabulated form in Table 25. These values have been
calculated from Marks and Davis Steam Tables by deducting from the total heat of one
pound of steam at any pressure for any degree of superheat the total heat of one pound of
saturated steam at the same pressure and dividing the difference by the number of degrees of
superheat and, therefore, represent the average specific heat starting from that at saturation to
the value at the particular pressure and temperature.[21] Expressed as a formula this
calculation is represented by
Hsup - Hsat
Sp. Ht. = –––––––––––––––––––– (8)
Ssup - Ssat
Where Hsup = total heat of one pound of superheated steam at any pressure and temperature,
Page 188
Hsat = total heat of one pound of saturated steam at same pressure, [Pg 138]
Ssup = temperature of superheated steam taken,
Ssat = temperature of saturated steam corresponding to the pressure taken.
TABLE 25
MEAN SPECIFIC HEAT OF SUPERHEATED STEAM
CALCULATED FROM MARKS AND DAVIS TABLES
Gauge Degree of Superheat
Pressure 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 225 250
50 .518.517 .514 .513 .511 .510 .508 .507 .505.504 .503 .502.501 .500.500 .499 .497.496
60 .528.525 .523 .521 .519 .517 .515 .513 .512 .511 .509 .508.507 .506.504 .504 .502.500
70 .536.534 .531 .529 .527 .524 .522 .520 .518.516 .515 .513.512 .511 .510 .509 .506.504
80 .544.542 .539 .535 .532 .530 .528 .526 .524.522 .520 .518.516 .515.514 .513 .511 .508
90 .553.550 .546 .543 .539 .536 .534 .532 .529.527 .525 .523.521 .519.518 .517 .514.510
100 .562.557 .553 .549 .544 .542 .539 .536 .533.531 .529 .527.525 .523.522 .521 .517.513
110 .570.565 .560 .556 .552 .548 .545 .542 .539.536 .534 .532.529 .528.526 .525 .520.517
120 .578.573 .567 .561 .557 .554 .550 .546 .543.540 .537 .535.533 .531.529 .528 .523.519
130 .586.580 .574 .569 .564 .560 .555 .552 .548.545 .542 .539.537 .535.533 .531 .527.523
140 .594.588 .581 .575 .570 .565 .561 .557 .553.550 .547 .544.541 .539.536 .534 .530.526
150 .604.595 .587 .581 .576 .570 .566 .561 .557.554 .550 .547.544 .542.539 .537 .533.529
160 .612.603 .596 .589 .582 .576 .571 .566 .562.558 .554 .551.548 .545.543 .541 .536.531
170 .620.612 .603 .595 .588 .582 .576 .571 .566.562 .558 .555.552 .549.546 .544 .538.533
180 .628.618 .610 .601 .593 .587 .581 .575 .570.566 .561 .558.555 .552.549 .546 .540.536
190 .638.627 .617 .608 .599 .592 .585 .579 .574.569 .565 .562.558 .555.552 .549 .543.538
200 .648.635 .624 .614 .605 .597 .590 .584 .578.574 .569 .566.562 .558.555 .552 .546.541
210 .656.643 .631 .620 .611 .602 .595 .588 .583.578 .573 .569.565 .561.558 .555 .549.543
220 .664.650 .637 .626 .616 .607 .600 .592 .586.581 .577 .572.568 .564.561 .558 .551.545
230 .672.658 .644 .633 .622 .613 .605 .597 .591.585 .580 .575.572 .567.564 .561 .554.548
240 .684.668 .653 .640 .629 .619 .610 .602 .595.589 .584 .579.575 .571.567 .564 .556.550
250 .692.675 .659 .645 .633 .623 .614 .606 .599.593 .587 .582.577 .574.570 .567 .559.553
Factor of Evaporation with Superheated Steam—When superheat is present in the steam
during a boiler trial, where superheated steam tables are available, the formula for
determining the factor of evaporation is that already given, (2),[22] namely,
H-h
Factor of evaporation = ––––––––––
L
Here H = total heat in one pound of superheated steam from the table, h and L having the
same values as in (2).
Ssup = temperature of superheated steam taken,
Ssat = temperature of saturated steam corresponding to the pressure taken.
TABLE 25
MEAN SPECIFIC HEAT OF SUPERHEATED STEAM
CALCULATED FROM MARKS AND DAVIS TABLES
Gauge Degree of Superheat
Pressure 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 225 250
50 .518.517 .514 .513 .511 .510 .508 .507 .505.504 .503 .502.501 .500.500 .499 .497.496
60 .528.525 .523 .521 .519 .517 .515 .513 .512 .511 .509 .508.507 .506.504 .504 .502.500
70 .536.534 .531 .529 .527 .524 .522 .520 .518.516 .515 .513.512 .511 .510 .509 .506.504
80 .544.542 .539 .535 .532 .530 .528 .526 .524.522 .520 .518.516 .515.514 .513 .511 .508
90 .553.550 .546 .543 .539 .536 .534 .532 .529.527 .525 .523.521 .519.518 .517 .514.510
100 .562.557 .553 .549 .544 .542 .539 .536 .533.531 .529 .527.525 .523.522 .521 .517.513
110 .570.565 .560 .556 .552 .548 .545 .542 .539.536 .534 .532.529 .528.526 .525 .520.517
120 .578.573 .567 .561 .557 .554 .550 .546 .543.540 .537 .535.533 .531.529 .528 .523.519
130 .586.580 .574 .569 .564 .560 .555 .552 .548.545 .542 .539.537 .535.533 .531 .527.523
140 .594.588 .581 .575 .570 .565 .561 .557 .553.550 .547 .544.541 .539.536 .534 .530.526
150 .604.595 .587 .581 .576 .570 .566 .561 .557.554 .550 .547.544 .542.539 .537 .533.529
160 .612.603 .596 .589 .582 .576 .571 .566 .562.558 .554 .551.548 .545.543 .541 .536.531
170 .620.612 .603 .595 .588 .582 .576 .571 .566.562 .558 .555.552 .549.546 .544 .538.533
180 .628.618 .610 .601 .593 .587 .581 .575 .570.566 .561 .558.555 .552.549 .546 .540.536
190 .638.627 .617 .608 .599 .592 .585 .579 .574.569 .565 .562.558 .555.552 .549 .543.538
200 .648.635 .624 .614 .605 .597 .590 .584 .578.574 .569 .566.562 .558.555 .552 .546.541
210 .656.643 .631 .620 .611 .602 .595 .588 .583.578 .573 .569.565 .561.558 .555 .549.543
220 .664.650 .637 .626 .616 .607 .600 .592 .586.581 .577 .572.568 .564.561 .558 .551.545
230 .672.658 .644 .633 .622 .613 .605 .597 .591.585 .580 .575.572 .567.564 .561 .554.548
240 .684.668 .653 .640 .629 .619 .610 .602 .595.589 .584 .579.575 .571.567 .564 .556.550
250 .692.675 .659 .645 .633 .623 .614 .606 .599.593 .587 .582.577 .574.570 .567 .559.553
Factor of Evaporation with Superheated Steam—When superheat is present in the steam
during a boiler trial, where superheated steam tables are available, the formula for
determining the factor of evaporation is that already given, (2),[22] namely,
H-h
Factor of evaporation = ––––––––––
L
Here H = total heat in one pound of superheated steam from the table, h and L having the
same values as in (2).
Page 189
Where no such tables are available but the specific heat of superheat is known, the formula
becomes:
H - h + Sp. Ht.(T - t)
Factor of evaporation = ––––––––––––––––––––––––––––––––––
L
Where H = total heat in one pound of saturated steam at pressure existing in trial,
h = sensible heat above 32 degrees in one pound of water at the temperature entering
the boiler,
tsat = temperature of saturated steam, corresponding to pressure existing,
T = temperature of superheated steam as determined in the trial, [Pg 139]
t = temperature of saturated steam corresponding to the boiler pressure,
Sp. Ht. = mean specific heat of superheated steam at the pressure and temperature as
found in the trial,
L = latent heat of one pound of saturated steam at atmospheric pressure.
Advantages of the Use of Superheated Steam—In considering the saving possible by the
use of superheated steam, it is too often assumed that there is only a saving in the prime
movers, a saving which is at least partially offset by an increase in the fuel consumption of
the boilers generating steam. This misconception is due to the fact that the fuel consumption
of the boiler is only considered in connection with a definite weight of steam. It is true that
where such a definite weight is to be superheated, an added amount of fuel must be burned.
With a properly designed superheater where the combined efficiency of the boiler and
superheater will be at least as high as of a boiler alone, the approximate increase in coal
consumption for producing a given weight of steam will be as follows:
Superheat Added Fuel Superheat Added Fuel
Degrees Per Cent Degrees Per Cent
25 1.59 100 5.69
50 3.07 150 8.19
75 4.38 200 0.58
These figures represent the added fuel necessary for superheating a definite weight of steam
to the number of degrees as given. The standard basis, however, of boiler evaporation is one
of heat units and, considered from such a standpoint, again providing the efficiency of the
boiler and superheater is as high, as of a boiler alone, there is no additional fuel required to
generate steam containing a definite number of heat units whether such units be due to
superheat or saturation. That is, if 6 per cent more fuel is required to generate and superheat
to 100 degrees, a definite weight of steam, over what would be required to produce the same
weight of saturated steam, that steam when superheated, will contain 6 per cent more heat
units above the fuel water temperature than if saturated. This holds true if the efficiency of
the boiler and superheater combined is the same as of the boiler alone. As a matter of fact,
the efficiency of a boiler and superheater, where the latter is properly designed and located,
will be slightly higher for the same set of furnace conditions than would the efficiency of a
becomes:
H - h + Sp. Ht.(T - t)
Factor of evaporation = ––––––––––––––––––––––––––––––––––
L
Where H = total heat in one pound of saturated steam at pressure existing in trial,
h = sensible heat above 32 degrees in one pound of water at the temperature entering
the boiler,
tsat = temperature of saturated steam, corresponding to pressure existing,
T = temperature of superheated steam as determined in the trial, [Pg 139]
t = temperature of saturated steam corresponding to the boiler pressure,
Sp. Ht. = mean specific heat of superheated steam at the pressure and temperature as
found in the trial,
L = latent heat of one pound of saturated steam at atmospheric pressure.
Advantages of the Use of Superheated Steam—In considering the saving possible by the
use of superheated steam, it is too often assumed that there is only a saving in the prime
movers, a saving which is at least partially offset by an increase in the fuel consumption of
the boilers generating steam. This misconception is due to the fact that the fuel consumption
of the boiler is only considered in connection with a definite weight of steam. It is true that
where such a definite weight is to be superheated, an added amount of fuel must be burned.
With a properly designed superheater where the combined efficiency of the boiler and
superheater will be at least as high as of a boiler alone, the approximate increase in coal
consumption for producing a given weight of steam will be as follows:
Superheat Added Fuel Superheat Added Fuel
Degrees Per Cent Degrees Per Cent
25 1.59 100 5.69
50 3.07 150 8.19
75 4.38 200 0.58
These figures represent the added fuel necessary for superheating a definite weight of steam
to the number of degrees as given. The standard basis, however, of boiler evaporation is one
of heat units and, considered from such a standpoint, again providing the efficiency of the
boiler and superheater is as high, as of a boiler alone, there is no additional fuel required to
generate steam containing a definite number of heat units whether such units be due to
superheat or saturation. That is, if 6 per cent more fuel is required to generate and superheat
to 100 degrees, a definite weight of steam, over what would be required to produce the same
weight of saturated steam, that steam when superheated, will contain 6 per cent more heat
units above the fuel water temperature than if saturated. This holds true if the efficiency of
the boiler and superheater combined is the same as of the boiler alone. As a matter of fact,
the efficiency of a boiler and superheater, where the latter is properly designed and located,
will be slightly higher for the same set of furnace conditions than would the efficiency of a
Page 190
boiler in which no superheater were installed. A superheater, properly placed within the
boiler setting in such way that products of combustion for generating saturated steam are
utilized as well for superheating that steam, will not in any way alter furnace conditions.
With a given set of such furnace conditions for a given amount of coal burned, the fact that
additional surface, whether as boiler heating or superheating surface, is placed in such a
manner that the gases must sweep over it, will tend to lower the temperature of the exit
gases. It is such a lowering of exit gas temperatures that is the ultimate indication of added
efficiency. Though the amount of this added efficiency is difficult to determine by test, that
there is an increase is unquestionable.
Where a properly designed superheater is installed in a boiler the heating surface of the
boiler proper, in the generation of a definite number of heat units, is relieved of a portion of
the work which would be required were these heat units delivered in saturated steam. Such a
superheater needs practically no attention, is not subject to a large upkeep cost or
depreciation, and performs its function without in any way [Pg 140] interfering with the
operation of the boiler. Its use, therefore from the standpoint of the boiler room, results in a
saving in wear and tear due to the lower ratings at which the boiler may be run, or its use will
lead to the possibility of obtaining the same number of boiler horse power from a smaller
number of boilers, with the boiler heating surface doing exactly the same amount of work as
if the superheaters were not installed. The saving due to the added boiler efficiency that will
be obtained is obvious.
Following the course of the steam in a plant, the next advantage of the use of superheated
steam is the absence of water in the steam pipes. The thermal conductivity of superheated
steam, that is, its power to give up its heat to surrounding bodies, is much lower than that of
saturated steam and its heat, therefore, will not be transmitted so rapidly to the walls of the
pipes as when saturated steam is flowing through the pipes. The loss of heat radiated from a
steam pipe, assuming no loss in pressure, represents the equivalent condensation when the
pipe is carrying saturated steam. In well-covered steam mains, the heat lost by radiation
when carrying superheated steam is accompanied only by a reduction of the superheat which,
if it be sufficiently high at the boiler, will enable a considerable amount of heat to be radiated
and still deliver dry or superheated steam to the prime movers.
It is in the prime movers that the advantages of the use of superheated steam are most clearly
seen.
In an engine, steam is admitted into a space that has been cooled by the steam exhausted
during the previous stroke. The heat necessary to warm the cylinder walls from the
temperature of the exhaust to that of the entering steam can be supplied only by the entering
steam. If this steam be saturated, such an adding of heat to the walls at the expense of the
heat of the entering steam results in the condensation of a portion. This initial condensation
is seldom less than from 20 to 30 per cent of the total weight of steam entering the cylinder.
It is obvious that if the steam entering be superheated, it must be reduced to the temperature
of saturated steam at the corresponding pressure before any condensation can take place. If
the steam be superheated sufficiently to allow a reduction in temperature equivalent to the
quantity of heat that must be imparted to the cylinder walls and still remain superheated, it is
boiler setting in such way that products of combustion for generating saturated steam are
utilized as well for superheating that steam, will not in any way alter furnace conditions.
With a given set of such furnace conditions for a given amount of coal burned, the fact that
additional surface, whether as boiler heating or superheating surface, is placed in such a
manner that the gases must sweep over it, will tend to lower the temperature of the exit
gases. It is such a lowering of exit gas temperatures that is the ultimate indication of added
efficiency. Though the amount of this added efficiency is difficult to determine by test, that
there is an increase is unquestionable.
Where a properly designed superheater is installed in a boiler the heating surface of the
boiler proper, in the generation of a definite number of heat units, is relieved of a portion of
the work which would be required were these heat units delivered in saturated steam. Such a
superheater needs practically no attention, is not subject to a large upkeep cost or
depreciation, and performs its function without in any way [Pg 140] interfering with the
operation of the boiler. Its use, therefore from the standpoint of the boiler room, results in a
saving in wear and tear due to the lower ratings at which the boiler may be run, or its use will
lead to the possibility of obtaining the same number of boiler horse power from a smaller
number of boilers, with the boiler heating surface doing exactly the same amount of work as
if the superheaters were not installed. The saving due to the added boiler efficiency that will
be obtained is obvious.
Following the course of the steam in a plant, the next advantage of the use of superheated
steam is the absence of water in the steam pipes. The thermal conductivity of superheated
steam, that is, its power to give up its heat to surrounding bodies, is much lower than that of
saturated steam and its heat, therefore, will not be transmitted so rapidly to the walls of the
pipes as when saturated steam is flowing through the pipes. The loss of heat radiated from a
steam pipe, assuming no loss in pressure, represents the equivalent condensation when the
pipe is carrying saturated steam. In well-covered steam mains, the heat lost by radiation
when carrying superheated steam is accompanied only by a reduction of the superheat which,
if it be sufficiently high at the boiler, will enable a considerable amount of heat to be radiated
and still deliver dry or superheated steam to the prime movers.
It is in the prime movers that the advantages of the use of superheated steam are most clearly
seen.
In an engine, steam is admitted into a space that has been cooled by the steam exhausted
during the previous stroke. The heat necessary to warm the cylinder walls from the
temperature of the exhaust to that of the entering steam can be supplied only by the entering
steam. If this steam be saturated, such an adding of heat to the walls at the expense of the
heat of the entering steam results in the condensation of a portion. This initial condensation
is seldom less than from 20 to 30 per cent of the total weight of steam entering the cylinder.
It is obvious that if the steam entering be superheated, it must be reduced to the temperature
of saturated steam at the corresponding pressure before any condensation can take place. If
the steam be superheated sufficiently to allow a reduction in temperature equivalent to the
quantity of heat that must be imparted to the cylinder walls and still remain superheated, it is
Page 191
clear that initial condensation is avoided. For example: assume one pound of saturated steam
at 200 pounds gauge pressure to enter a cylinder which has been cooled by the exhaust.
Assume the initial condensation to be 20 per cent. The latent heat of the steam is given up in
condensation; hence, .20 × 838 = 167.6 B. t. u. are given up by the steam. If one pound of
superheated steam enters the same cylinder, it would have to be superheated to a point where
its total heat is 1199 + 168 = 1367 B. t. u. or, at 200 pounds gauge pressure, superheated
approximately 325 degrees if the heat given up to the cylinder walls were the same as for the
saturated steam. As superheated steam conducts heat less rapidly than saturated steam, the
amount of heat imparted will be less than for the saturated steam and consequently the
amount of superheat required to prevent condensation will be less than the above figure.
This, of course, is the extreme case of a simple engine with the range of temperature change
a maximum. As cylinders are added, the range in each is decreased and the condensation is
proportionate.
The true economy of the use of superheated steam is best shown in a comparison of the “heat
consumption” of an engine. This is the number of heat units required [Pg 141] in developing
one indicated horse power and the measure of the relative performance of two engines is
based on a comparison of their heat consumption as the measure of a boiler is based on its
evaporation from and at 212 degrees. The water consumption of an engine in pounds per
indicated horse power is in no sense a true indication of its efficiency. The initial pressures
and corresponding temperatures may differ widely and thus make a difference in the
temperature of the exhaust and hence in the temperature of the condensed steam returned to
the boiler. For example: suppose a certain weight of steam at 150 pounds absolute pressure
and 358 degrees be expanded to atmospheric pressure, the temperature then being 212
degrees. If the same weight of steam be expanded from an initial pressure of 125 pounds
absolute and 344 degrees, to enable it to do the same amount of work, that is, to give up the
same amount of heat, expansion then must be carried to a point below atmospheric pressure
to, say, 13 pounds absolute, the final temperature of the steam then being 206 degrees. In
actual practice, it has been observed that the water consumption of a compound piston
engine running on 26-inch vacuum and returning the condensed steam at 140 degrees was
approximately the same as when running on 28-inch vacuum and returning water at 90
degrees. With an equal water consumption for the two sets of conditions, the economy in the
former case would be greater than in the latter, since it would be necessary to add less heat to
the water returned to the boiler to raise it to the steam temperature.
The lower the heat consumption of an engine per indicated horse power, the higher its
economy and the less the number of heat units must be imparted to the steam generated. This
in turn leads to the lowering of the amount of fuel that must be burned per indicated horse
power.
With the saving in fuel by the reduction of heat consumption of an engine indicated, it
remains to be shown the effect of the use of superheated steam on such heat consumption. As
already explained, the use of superheated steam reduces condensation not only in the mains
but especially in the steam cylinder, leaving a greater quantity of steam available to do the
work. Furthermore, a portion of the saturated steam introduced into a cylinder will condense
during adiabatic expansion, this condensation increasing as expansion progresses. Since
at 200 pounds gauge pressure to enter a cylinder which has been cooled by the exhaust.
Assume the initial condensation to be 20 per cent. The latent heat of the steam is given up in
condensation; hence, .20 × 838 = 167.6 B. t. u. are given up by the steam. If one pound of
superheated steam enters the same cylinder, it would have to be superheated to a point where
its total heat is 1199 + 168 = 1367 B. t. u. or, at 200 pounds gauge pressure, superheated
approximately 325 degrees if the heat given up to the cylinder walls were the same as for the
saturated steam. As superheated steam conducts heat less rapidly than saturated steam, the
amount of heat imparted will be less than for the saturated steam and consequently the
amount of superheat required to prevent condensation will be less than the above figure.
This, of course, is the extreme case of a simple engine with the range of temperature change
a maximum. As cylinders are added, the range in each is decreased and the condensation is
proportionate.
The true economy of the use of superheated steam is best shown in a comparison of the “heat
consumption” of an engine. This is the number of heat units required [Pg 141] in developing
one indicated horse power and the measure of the relative performance of two engines is
based on a comparison of their heat consumption as the measure of a boiler is based on its
evaporation from and at 212 degrees. The water consumption of an engine in pounds per
indicated horse power is in no sense a true indication of its efficiency. The initial pressures
and corresponding temperatures may differ widely and thus make a difference in the
temperature of the exhaust and hence in the temperature of the condensed steam returned to
the boiler. For example: suppose a certain weight of steam at 150 pounds absolute pressure
and 358 degrees be expanded to atmospheric pressure, the temperature then being 212
degrees. If the same weight of steam be expanded from an initial pressure of 125 pounds
absolute and 344 degrees, to enable it to do the same amount of work, that is, to give up the
same amount of heat, expansion then must be carried to a point below atmospheric pressure
to, say, 13 pounds absolute, the final temperature of the steam then being 206 degrees. In
actual practice, it has been observed that the water consumption of a compound piston
engine running on 26-inch vacuum and returning the condensed steam at 140 degrees was
approximately the same as when running on 28-inch vacuum and returning water at 90
degrees. With an equal water consumption for the two sets of conditions, the economy in the
former case would be greater than in the latter, since it would be necessary to add less heat to
the water returned to the boiler to raise it to the steam temperature.
The lower the heat consumption of an engine per indicated horse power, the higher its
economy and the less the number of heat units must be imparted to the steam generated. This
in turn leads to the lowering of the amount of fuel that must be burned per indicated horse
power.
With the saving in fuel by the reduction of heat consumption of an engine indicated, it
remains to be shown the effect of the use of superheated steam on such heat consumption. As
already explained, the use of superheated steam reduces condensation not only in the mains
but especially in the steam cylinder, leaving a greater quantity of steam available to do the
work. Furthermore, a portion of the saturated steam introduced into a cylinder will condense
during adiabatic expansion, this condensation increasing as expansion progresses. Since
Page 192
superheated steam cannot condense until it becomes saturated, not only is initial
condensation prevented by its use but also such condensation as would occur during
expansion. When superheated sufficiently, steam delivered by the exhaust will still be dry. In
the avoidance of such condensation, there is a direct saving in the heat consumption of an
engine, the heat given up being utilized in the developing of power and not in changing the
condition of the working fluid. That is, while the number of heat units lost in overcoming
condensation effects would be the same in either case, when saturated steam is condensed
the water of condensation has no power to do work while the superheated steam, even after it
has lost a like number of heat units, still has the power of expansion. The saving through the
use of superheated steam in the heat consumption of an engine decreases demands on the
boiler and hence the fuel consumption per unit of power.
Superheated Steam for Steam Turbines—Experience in using superheated steam in
connection with steam turbines has shown that it leads to economy and that it undoubtedly
pays to use superheated steam in place of saturated steam. This is so well established that it
is standard practice to use superheated steam in connection [Pg 142] with steam turbines. Aside
from the economy secured through using superheated steam, there is an important advantage
arising through the fact that it materially reduces the erosion of the turbine blades by the
action of water that would be carried by saturated steam. In using saturated steam in a steam
turbine or piston engine, the work done on expanding the steam causes condensation of a
portion of the steam, so that even were the steam dry on entering the turbine, it would
contain water on leaving the turbine. By superheating the steam the water that exists in the
low pressure stages of the turbine may be reduced to an amount that will not cause trouble.
Again, if saturated steam contains moisture, the effect of this moisture on the economy of a
steam turbine is to reduce the economy to a greater extent than the proportion by weight of
water, one per cent of water causing approximately a falling off of 2 per cent in the economy.
The water rate of a large economical steam turbine with superheated steam is reduced about
one per cent, for every 12 degrees of superheat up to 200 degrees Fahrenheit of superheat. To
superheat one pound of steam 12 degrees requires about 7 B. t. u. and if 1050 B. t. u. are
required at the boiler to evaporate one pound of the saturated steam from the temperature of
the feed water, the heat required for the superheated steam would be 1057 degrees. One per
cent of saving, therefore, in the water consumption would correspond to a net saving of
about one-third of one per cent in the coal consumption. On this basis 100 degrees of
superheat with an economical steam turbine would result in somewhat over 3 per cent of
saving in the coal for equal boiler efficiencies. As a boiler with a properly designed
superheater placed within the setting is more economical for a given capacity than a boiler
without a superheater, the minimum gain in the coal consumption would be, say, 4 or 5 per
cent as compared to a plant with the same boilers without superheaters.
The above estimates are on the basis of a thoroughly dry saturated steam or steam just at the
point of being superheated or containing a few degrees of superheat. If the saturated steam is
moist, the saving due to superheat is more and ordinarily the gain in economy due to
superheated steam, for equal boiler efficiencies, as compared with commercially dry steam
is, say, 5 per cent for each 100 degrees of superheat. Aside from this gain, as already stated,
condensation prevented by its use but also such condensation as would occur during
expansion. When superheated sufficiently, steam delivered by the exhaust will still be dry. In
the avoidance of such condensation, there is a direct saving in the heat consumption of an
engine, the heat given up being utilized in the developing of power and not in changing the
condition of the working fluid. That is, while the number of heat units lost in overcoming
condensation effects would be the same in either case, when saturated steam is condensed
the water of condensation has no power to do work while the superheated steam, even after it
has lost a like number of heat units, still has the power of expansion. The saving through the
use of superheated steam in the heat consumption of an engine decreases demands on the
boiler and hence the fuel consumption per unit of power.
Superheated Steam for Steam Turbines—Experience in using superheated steam in
connection with steam turbines has shown that it leads to economy and that it undoubtedly
pays to use superheated steam in place of saturated steam. This is so well established that it
is standard practice to use superheated steam in connection [Pg 142] with steam turbines. Aside
from the economy secured through using superheated steam, there is an important advantage
arising through the fact that it materially reduces the erosion of the turbine blades by the
action of water that would be carried by saturated steam. In using saturated steam in a steam
turbine or piston engine, the work done on expanding the steam causes condensation of a
portion of the steam, so that even were the steam dry on entering the turbine, it would
contain water on leaving the turbine. By superheating the steam the water that exists in the
low pressure stages of the turbine may be reduced to an amount that will not cause trouble.
Again, if saturated steam contains moisture, the effect of this moisture on the economy of a
steam turbine is to reduce the economy to a greater extent than the proportion by weight of
water, one per cent of water causing approximately a falling off of 2 per cent in the economy.
The water rate of a large economical steam turbine with superheated steam is reduced about
one per cent, for every 12 degrees of superheat up to 200 degrees Fahrenheit of superheat. To
superheat one pound of steam 12 degrees requires about 7 B. t. u. and if 1050 B. t. u. are
required at the boiler to evaporate one pound of the saturated steam from the temperature of
the feed water, the heat required for the superheated steam would be 1057 degrees. One per
cent of saving, therefore, in the water consumption would correspond to a net saving of
about one-third of one per cent in the coal consumption. On this basis 100 degrees of
superheat with an economical steam turbine would result in somewhat over 3 per cent of
saving in the coal for equal boiler efficiencies. As a boiler with a properly designed
superheater placed within the setting is more economical for a given capacity than a boiler
without a superheater, the minimum gain in the coal consumption would be, say, 4 or 5 per
cent as compared to a plant with the same boilers without superheaters.
The above estimates are on the basis of a thoroughly dry saturated steam or steam just at the
point of being superheated or containing a few degrees of superheat. If the saturated steam is
moist, the saving due to superheat is more and ordinarily the gain in economy due to
superheated steam, for equal boiler efficiencies, as compared with commercially dry steam
is, say, 5 per cent for each 100 degrees of superheat. Aside from this gain, as already stated,
Page 193
superheated steam prevents erosion of the turbine buckets that would be caused by water in
the steam, and for the reasons enumerated it is standard practice to use superheated steam for
turbine work. The less economical the steam motor, the more the gain due to superheated
steam, and where there are a number of auxiliaries that are run with superheated steam, the
percentage of gain will be greater than the figures given above, which are the minimum and
are for the most economical type of large steam turbines.
An example from actual practice will perhaps best illustrate and emphasize the foregoing
facts. In October 1909, a series of comparable tests were conducted by The Babcock &
Wilcox Co. on the steam yacht “Idalia” to determine the steam consumption both with
saturated and superheated steam of the main engine on that yacht, including as well the feed
pump, circulating pump and air pump. These tests are more representative than are most tests
of like character in that the saving in the steam consumption of the auxiliaries, which were
much more wasteful than the main engine, formed an important factor. A résumé of these
tests was published in the Journal of the Society of Naval Engineers, November 1909.
[Pg 143]
The main engines of the “Idalia” are four cylinder, triple expansion, 111⁄2 × 19 inches by
2211⁄16 × 18 inches stroke. Steam is supplied by a Babcock & Wilcox marine boiler having
2500 square feet of boiler heating surface, 340 square feet of superheating surface and 65
square feet of grate surface.
The auxiliaries consist of a feed pump 6 × 4 × 6 inches, an independent air pump 6 × 12 × 8
inches, and a centrifugal pump driven by a reciprocating engine 57⁄16 × 5 inches. Under
ordinary operating conditions the superheat existing is about 100 degrees Fahrenheit.
Tests were made with various degrees of superheat, the amount being varied by by-passing
the gases and in the tests with the lower amounts of superheat by passing a portion of the
steam from the boiler to the steam main without passing it through the superheater. Steam
temperature readings were taken at the engine throttle. In the tests with saturated steam, the
superheater was completely cut out of the system. Careful calorimeter measurements were
taken, showing that the saturated steam delivered to the superheater was dry.
The weight of steam used was determined from the weight of the condensed steam discharge
from the surface condenser, the water being pumped from the hot well into a tank mounted
on platform scales. The same indicators, thermometers and gauges were used in all the tests,
so that the results are directly comparable. The indicators used were of the outside spring
type so that there was no effect of the temperature of the steam. All tests were of sufficient
duration to show a uniformity of results by hours. A summary of the results secured is given
in Table 26, which shows the water rate per indicated horse power and the heat consumption.
The latter figures are computed on the basis of the heat imparted to the steam above the
actual temperature of the feed water and, as stated, these are the results that are directly
comparable.
the steam, and for the reasons enumerated it is standard practice to use superheated steam for
turbine work. The less economical the steam motor, the more the gain due to superheated
steam, and where there are a number of auxiliaries that are run with superheated steam, the
percentage of gain will be greater than the figures given above, which are the minimum and
are for the most economical type of large steam turbines.
An example from actual practice will perhaps best illustrate and emphasize the foregoing
facts. In October 1909, a series of comparable tests were conducted by The Babcock &
Wilcox Co. on the steam yacht “Idalia” to determine the steam consumption both with
saturated and superheated steam of the main engine on that yacht, including as well the feed
pump, circulating pump and air pump. These tests are more representative than are most tests
of like character in that the saving in the steam consumption of the auxiliaries, which were
much more wasteful than the main engine, formed an important factor. A résumé of these
tests was published in the Journal of the Society of Naval Engineers, November 1909.
[Pg 143]
The main engines of the “Idalia” are four cylinder, triple expansion, 111⁄2 × 19 inches by
2211⁄16 × 18 inches stroke. Steam is supplied by a Babcock & Wilcox marine boiler having
2500 square feet of boiler heating surface, 340 square feet of superheating surface and 65
square feet of grate surface.
The auxiliaries consist of a feed pump 6 × 4 × 6 inches, an independent air pump 6 × 12 × 8
inches, and a centrifugal pump driven by a reciprocating engine 57⁄16 × 5 inches. Under
ordinary operating conditions the superheat existing is about 100 degrees Fahrenheit.
Tests were made with various degrees of superheat, the amount being varied by by-passing
the gases and in the tests with the lower amounts of superheat by passing a portion of the
steam from the boiler to the steam main without passing it through the superheater. Steam
temperature readings were taken at the engine throttle. In the tests with saturated steam, the
superheater was completely cut out of the system. Careful calorimeter measurements were
taken, showing that the saturated steam delivered to the superheater was dry.
The weight of steam used was determined from the weight of the condensed steam discharge
from the surface condenser, the water being pumped from the hot well into a tank mounted
on platform scales. The same indicators, thermometers and gauges were used in all the tests,
so that the results are directly comparable. The indicators used were of the outside spring
type so that there was no effect of the temperature of the steam. All tests were of sufficient
duration to show a uniformity of results by hours. A summary of the results secured is given
in Table 26, which shows the water rate per indicated horse power and the heat consumption.
The latter figures are computed on the basis of the heat imparted to the steam above the
actual temperature of the feed water and, as stated, these are the results that are directly
comparable.
Page 194
TABLE 26
RESULTS OF “IDALIA” TESTS
Oct. Oct. Oct. Oct.
Date 1909 Oct. 11
14 14 12 13
Degrees of superheat Fahrenheit 0 7 88 96 105
Pressures, pounds per Throttle 190 196 201 198 203
square inch above First Receiver 68.4 66.0 64.3 61.9 63.0
Atmospheric Pressure Second Receiver 9.7 9.2 8.7 7.8 8.4
Vacuum, inches 25.5 25.9 25.9 25.4 25.2
Temperature, Degrees Feed 201 206 205 202 200
Fahrenheit Hot Well 116 109.5 115 111.5 111
Air Pump 57 56 53 54 45
Circulating
Revolutions per minute 196 198 196 198 197
Pump
Main Engine 194.3 191.5 195.1 191.5 193.1
Indicated Horse Power, Main Engine 512.3 495.2 521.1 498.3 502.2
Water per hour, total pounds 9397 8430 8234 7902 7790
Water per indicated Horse Power, pounds 18.3 17.0 15.8 15.8 15.5
B. t. u. per minute per indicated Horse Power 314 300 284 286 283
Per cent Saving of Steam … 7.1 13.7 13.7 15.3
Percent Saving of Fuel (computed) … 4.4 9.5 8.9 9.9
The table shows that the saving in steam consumption with 105 degrees of superheat was
15.3 per cent and in heat consumption about 10 per cent. This may be [Pg 144] safely stated to
be a conservative representation of the saving that may be accomplished by the use of
superheated steam in a plant as a whole, where superheated steam is furnished not only to the
main engine but also to the auxiliaries. The figures may be taken as conservative for the
reason that in addition to the saving as shown in the table, there would be in an ordinary
plant a saving much greater than is generally realized in the drips, where the loss with
saturated steam is greatly in excess of that with superheated steam.
The most conclusive and most practical evidence that a saving is possible through the use of
superheated steam is in the fact that in the largest and most economical plants it is used
almost without exception. Regardless of any such evidence, however, there is a deep rooted
conviction in the minds of certain engineers that the use of superheated steam will involve
operating difficulties which, with additional first cost, will more than offset any fuel saving.
There are, of course, conditions under which the installation of superheaters would in no way
be advisable. With a poorly designed superheater, no gain would result. In general, it may be
stated that in a new plant, properly designed, with a boiler and superheater which will have
an efficiency at least as high as a boiler without a superheater, a gain is certain.
Such a gain is dependent upon the class of engine and the power plant equipment in general.
In determining the advisability of making a superheater installation, all of the factors
RESULTS OF “IDALIA” TESTS
Oct. Oct. Oct. Oct.
Date 1909 Oct. 11
14 14 12 13
Degrees of superheat Fahrenheit 0 7 88 96 105
Pressures, pounds per Throttle 190 196 201 198 203
square inch above First Receiver 68.4 66.0 64.3 61.9 63.0
Atmospheric Pressure Second Receiver 9.7 9.2 8.7 7.8 8.4
Vacuum, inches 25.5 25.9 25.9 25.4 25.2
Temperature, Degrees Feed 201 206 205 202 200
Fahrenheit Hot Well 116 109.5 115 111.5 111
Air Pump 57 56 53 54 45
Circulating
Revolutions per minute 196 198 196 198 197
Pump
Main Engine 194.3 191.5 195.1 191.5 193.1
Indicated Horse Power, Main Engine 512.3 495.2 521.1 498.3 502.2
Water per hour, total pounds 9397 8430 8234 7902 7790
Water per indicated Horse Power, pounds 18.3 17.0 15.8 15.8 15.5
B. t. u. per minute per indicated Horse Power 314 300 284 286 283
Per cent Saving of Steam … 7.1 13.7 13.7 15.3
Percent Saving of Fuel (computed) … 4.4 9.5 8.9 9.9
The table shows that the saving in steam consumption with 105 degrees of superheat was
15.3 per cent and in heat consumption about 10 per cent. This may be [Pg 144] safely stated to
be a conservative representation of the saving that may be accomplished by the use of
superheated steam in a plant as a whole, where superheated steam is furnished not only to the
main engine but also to the auxiliaries. The figures may be taken as conservative for the
reason that in addition to the saving as shown in the table, there would be in an ordinary
plant a saving much greater than is generally realized in the drips, where the loss with
saturated steam is greatly in excess of that with superheated steam.
The most conclusive and most practical evidence that a saving is possible through the use of
superheated steam is in the fact that in the largest and most economical plants it is used
almost without exception. Regardless of any such evidence, however, there is a deep rooted
conviction in the minds of certain engineers that the use of superheated steam will involve
operating difficulties which, with additional first cost, will more than offset any fuel saving.
There are, of course, conditions under which the installation of superheaters would in no way
be advisable. With a poorly designed superheater, no gain would result. In general, it may be
stated that in a new plant, properly designed, with a boiler and superheater which will have
an efficiency at least as high as a boiler without a superheater, a gain is certain.
Such a gain is dependent upon the class of engine and the power plant equipment in general.
In determining the advisability of making a superheater installation, all of the factors
Page 195
entering into each individual case should be considered and balanced, with a view to
determining the saving in relation to cost, maintenance, depreciation etc.
In highly economical plants, where the water consumption for an indicated horse power is
low, the gain will be less than would result from the use of superheated steam in less
economical plants where the water consumption is higher. It is impossible to make an
accurate statement as to the saving possible but, broadly, it may vary from 3 to 5 per cent for
100 degrees of superheat in the large and economical plants using turbines or steam engines,
in which there is a large ratio of expansion, to from 10 to 25 per cent for 100 degrees of
superheat for the less economical steam motors.
Though a properly designed superheater will tend to raise rather than to decrease the boiler
efficiency, it does not follow that all superheaters are efficient, for if the gases in passing
over the superheater do not follow the path they would ordinarily take in passing over the
boiler heating surface, a loss may result. This is noticeably true where part of the gases are
passed over the superheater and are allowed to pass over only a part or in some cases none of
the boiler heating surface.
With moderate degrees of superheat, from 100 to 200 degrees, where the piping is properly
installed, there will be no greater operating difficulties than with saturated steam. Engine and
turbine builders guarantee satisfactory operation with superheated steam. With high degrees
of superheat, say, over 250 degrees, apparatus of a special nature must be used and it is
questionable whether the additional care and liability to operating difficulties will offset any
fuel saving accomplished. It is well established, however, that the operating difficulties, with
the degrees of superheat to which this article is limited, have been entirely overcome.
The use of cast-iron fittings with superheated steam has been widely discussed. It is an
undoubted fact that while in some instances superheated steam has caused deterioration of
such fittings, in others cast-iron fittings have been used with 150 degrees of superheat
without the least difficulty. The quality of the cast iron used in [Pg 145] such fittings has
doubtless a large bearing on the life of such fittings for this service. The difficulties that have
been encountered are an increase in the size of the fittings and eventually a deterioration
great enough to lead to serious breakage, the development of cracks, and when flanges are
drawn up too tightly, the breaking of a flange from the body of the fitting. The latter
difficulty is undoubtedly due, in certain instances, to the form of flange in which the strain of
the connecting bolts tended to distort the metal.
The Babcock & Wilcox Co. have used steel castings in superheated steam work over a long
period and experience has shown that this metal is suitable for the service. There seems to be
a general tendency toward the use of steel fittings. In European practice, until recently, cast
iron was used with apparently satisfactory results. The claim of European engineers was to
the effect that their cast iron was of better quality than that found in this country and thus
explained the results secured. Recently, however, certain difficulties have been encountered
with such fittings and European engineers are leaning toward the use of steel for this work.
determining the saving in relation to cost, maintenance, depreciation etc.
In highly economical plants, where the water consumption for an indicated horse power is
low, the gain will be less than would result from the use of superheated steam in less
economical plants where the water consumption is higher. It is impossible to make an
accurate statement as to the saving possible but, broadly, it may vary from 3 to 5 per cent for
100 degrees of superheat in the large and economical plants using turbines or steam engines,
in which there is a large ratio of expansion, to from 10 to 25 per cent for 100 degrees of
superheat for the less economical steam motors.
Though a properly designed superheater will tend to raise rather than to decrease the boiler
efficiency, it does not follow that all superheaters are efficient, for if the gases in passing
over the superheater do not follow the path they would ordinarily take in passing over the
boiler heating surface, a loss may result. This is noticeably true where part of the gases are
passed over the superheater and are allowed to pass over only a part or in some cases none of
the boiler heating surface.
With moderate degrees of superheat, from 100 to 200 degrees, where the piping is properly
installed, there will be no greater operating difficulties than with saturated steam. Engine and
turbine builders guarantee satisfactory operation with superheated steam. With high degrees
of superheat, say, over 250 degrees, apparatus of a special nature must be used and it is
questionable whether the additional care and liability to operating difficulties will offset any
fuel saving accomplished. It is well established, however, that the operating difficulties, with
the degrees of superheat to which this article is limited, have been entirely overcome.
The use of cast-iron fittings with superheated steam has been widely discussed. It is an
undoubted fact that while in some instances superheated steam has caused deterioration of
such fittings, in others cast-iron fittings have been used with 150 degrees of superheat
without the least difficulty. The quality of the cast iron used in [Pg 145] such fittings has
doubtless a large bearing on the life of such fittings for this service. The difficulties that have
been encountered are an increase in the size of the fittings and eventually a deterioration
great enough to lead to serious breakage, the development of cracks, and when flanges are
drawn up too tightly, the breaking of a flange from the body of the fitting. The latter
difficulty is undoubtedly due, in certain instances, to the form of flange in which the strain of
the connecting bolts tended to distort the metal.
The Babcock & Wilcox Co. have used steel castings in superheated steam work over a long
period and experience has shown that this metal is suitable for the service. There seems to be
a general tendency toward the use of steel fittings. In European practice, until recently, cast
iron was used with apparently satisfactory results. The claim of European engineers was to
the effect that their cast iron was of better quality than that found in this country and thus
explained the results secured. Recently, however, certain difficulties have been encountered
with such fittings and European engineers are leaning toward the use of steel for this work.
Page 196
The degree of superheat produced by a superheater placed within the boiler setting will vary
according to the class of fuel used, the form of furnace, the condition of the fire and the rate
at which the boiler is being operated. This is necessarily true of any superheater swept by the
main body of the products of combustion and is a fact that should be appreciated by the
prospective user of superheated steam. With a properly designed superheater, however, such
fluctuations would not be excessive, provided the boilers are properly operated. As a matter
of fact the point to be guarded against in the use of superheated steam is that a maximum
should not be exceeded. While, as stated, there may be a considerable fluctuation in the
temperature of the steam as delivered from individual superheaters, where there are a number
of boilers on a line the temperature of the combined flow of steam in the main will be found
to be practically a constant, resulting from the offsetting of various furnace conditions of one
boiler by another.
[Pg 146]
8400 Horse-power Installation of Babcock & Wilcox Boilers and Superheaters at the
Butler Street Plant of the Georgia Railway and Power Co., Atlanta, Ga. This Company
Operates a Total of 15,200 Horse Power of Babcock & Wilcox Boilers
FOOTNOTES
according to the class of fuel used, the form of furnace, the condition of the fire and the rate
at which the boiler is being operated. This is necessarily true of any superheater swept by the
main body of the products of combustion and is a fact that should be appreciated by the
prospective user of superheated steam. With a properly designed superheater, however, such
fluctuations would not be excessive, provided the boilers are properly operated. As a matter
of fact the point to be guarded against in the use of superheated steam is that a maximum
should not be exceeded. While, as stated, there may be a considerable fluctuation in the
temperature of the steam as delivered from individual superheaters, where there are a number
of boilers on a line the temperature of the combined flow of steam in the main will be found
to be practically a constant, resulting from the offsetting of various furnace conditions of one
boiler by another.
[Pg 146]
8400 Horse-power Installation of Babcock & Wilcox Boilers and Superheaters at the
Butler Street Plant of the Georgia Railway and Power Co., Atlanta, Ga. This Company
Operates a Total of 15,200 Horse Power of Babcock & Wilcox Boilers
FOOTNOTES
Page 197
[20] See pages 125 to 127.
[21] The actual specific heat at a particular temperature and pressure is that corresponding to a
change of one degree one way or the other and differs considerably from the average value for the
particular temperature and pressure given in the table. The mean values given in the table give
correct results when employed to determine the factor of evaporation whereas the actual values at
the particular temperatures and pressures would not.
[22] See page 117.
[21] The actual specific heat at a particular temperature and pressure is that corresponding to a
change of one degree one way or the other and differs considerably from the average value for the
particular temperature and pressure given in the table. The mean values given in the table give
correct results when employed to determine the factor of evaporation whereas the actual values at
the particular temperatures and pressures would not.
[22] See page 117.
Page 198
[Pg 147]
Page 199
PROPERTIES OF AIR
Pure air is a mechanical mixture of oxygen and nitrogen. While different authorities give slightly
varying values for the proportion of oxygen and nitrogen contained, the generally accepted values are:
By volume, oxygen 20.91 per cent, nitrogen 79.09 per cent.
By weight, oxygen 23.15 per cent, nitrogen 76.85 per cent.
Air in nature always contains other constituents in varying amounts, such as dust, carbon dioxide,
ozone and water vapor.
Being perfectly elastic, the density or weight per unit of volume decreases in geometric progression
with the altitude. This fact has a direct bearing in the proportioning of furnaces, flues and stacks at
high altitudes, as will be shown later in the discussion of these subjects. The atmospheric pressures
corresponding to various altitudes are given in Table 12 .
The weight and volume of air depend upon the pressure and the temperature, as expressed by the
formula:
P v = 53.33 T (9)
Where P = the absolute pressure in pounds per square foot,
v = the volume in cubic feet of one pound of air,
T = the absolute temperature of the air in degrees Fahrenheit,
53.33 = a constant for air derived from the ratio of pressure, volume and temperature of a perfect
gas.
The weight of one cubic foot of air will obviously be the reciprocal of its volume, that is, 1/ v pounds.
TABLE 27
VOLUME AND WEIGHT OF AIR
AT ATMOSPHERIC PRESSURE AT VARIOUS TEMPERATURES
Volume Weight Volume Weight Volume Weight
One One One One One One
Temperature Temperature Temperature
Pound Cubic Pound Cubic Pound Cubic
Degrees Degrees Degrees
in Foot in Foot in Foot
Fahrenheit Fahrenheit Fahrenheit
Cubic in Cubic in Cubic in
Feet Pounds Feet Pounds Feet Pounds
32 12.390 .080710 160 15.615 .064041 340 20.151 .049625
50 12.843 .077863 170 15.867 .063024 360 20.655 .048414
55 12.969 .077107 180 16.119 .062039 380 21.159 .047261
60 13.095 .076365 190 16.371 .061084 400 21.663 .046162
65 13.221 .075637 200 16.623 .060158 425 22.293 .044857
70 13.347 .074923 210 16.875 .059259 450 22.923 .043624
75 13.473 .074223 212 16.925 .059084 475 23.554 .042456
80 13.599 .073535 220 17.127 .058388 500 24.184 .041350
Pure air is a mechanical mixture of oxygen and nitrogen. While different authorities give slightly
varying values for the proportion of oxygen and nitrogen contained, the generally accepted values are:
By volume, oxygen 20.91 per cent, nitrogen 79.09 per cent.
By weight, oxygen 23.15 per cent, nitrogen 76.85 per cent.
Air in nature always contains other constituents in varying amounts, such as dust, carbon dioxide,
ozone and water vapor.
Being perfectly elastic, the density or weight per unit of volume decreases in geometric progression
with the altitude. This fact has a direct bearing in the proportioning of furnaces, flues and stacks at
high altitudes, as will be shown later in the discussion of these subjects. The atmospheric pressures
corresponding to various altitudes are given in Table 12 .
The weight and volume of air depend upon the pressure and the temperature, as expressed by the
formula:
P v = 53.33 T (9)
Where P = the absolute pressure in pounds per square foot,
v = the volume in cubic feet of one pound of air,
T = the absolute temperature of the air in degrees Fahrenheit,
53.33 = a constant for air derived from the ratio of pressure, volume and temperature of a perfect
gas.
The weight of one cubic foot of air will obviously be the reciprocal of its volume, that is, 1/ v pounds.
TABLE 27
VOLUME AND WEIGHT OF AIR
AT ATMOSPHERIC PRESSURE AT VARIOUS TEMPERATURES
Volume Weight Volume Weight Volume Weight
One One One One One One
Temperature Temperature Temperature
Pound Cubic Pound Cubic Pound Cubic
Degrees Degrees Degrees
in Foot in Foot in Foot
Fahrenheit Fahrenheit Fahrenheit
Cubic in Cubic in Cubic in
Feet Pounds Feet Pounds Feet Pounds
32 12.390 .080710 160 15.615 .064041 340 20.151 .049625
50 12.843 .077863 170 15.867 .063024 360 20.655 .048414
55 12.969 .077107 180 16.119 .062039 380 21.159 .047261
60 13.095 .076365 190 16.371 .061084 400 21.663 .046162
65 13.221 .075637 200 16.623 .060158 425 22.293 .044857
70 13.347 .074923 210 16.875 .059259 450 22.923 .043624
75 13.473 .074223 212 16.925 .059084 475 23.554 .042456
80 13.599 .073535 220 17.127 .058388 500 24.184 .041350
Page 200
85 13.725 .072860 230 17.379 .057541 525 24.814 .040300
90 13.851 .072197 240 17.631 .056718 550 25.444 .039302
95 13.977 .071546 250 17.883 .055919 575 26.074 .038352
100 14.103 .070907 260 18.135 .055142 600 26.704 .037448
110 14.355 .069662 270 18.387 .054386 650 27.964 .035760
120 14.607 .068460 280 18.639 .053651 700 29.224 .034219
130 14.859 .067299 290 18.891 .052935 750 30.484 .032804
140 15.111 .066177 300 19.143 .052238 800 31.744 .031502
150 15.363 .065092 320 19.647 .050898 850 33.004 .030299
[Pg 148]
Example: Required the volume of air in cubic feet under 60.3 pounds gauge pressure per square inch at
115 degrees Fahrenheit.
P = 144 (14.7 + 60.3) = 10,800.
T = 115 + 460 = 575 degrees.
53.33 × 575
Hence v = –––––––––––––––––––– = 2.84 cubic feet, and
10,800
1 1
Weight per cubic foot = –––– = –––––––– = 0.352 pounds.
v 2.84
Table 27 gives the weights and volumes of air under atmospheric pressure at varying temperatures.
Formula ( 9 ) holds good for other gases with the change in the value of the constant as follows:
For oxygen 48.24, nitrogen 54.97, hydrogen 765.71.
The specific heat of air at constant pressure varies with its temperature. A number of determinations of
this value have been made and certain of those ordinarily accepted as most authentic are given in Table
28 .
TABLE 28
SPECIFIC HEAT OF AIR
AT CONSTANT PRESSURE AND VARIOUS TEMPERATURES
Temperature Range
Specific Heat Authority
Degrees Centigrade Degrees Fahrenheit
-30– 10 -22– 50 0.2377 Regnault
0–100 32– 212 0.2374 Regnault
0–200 32– 392 0.2375 Regnault
20–440 68– 824 0.2366 Holborn and Curtis
20–630 68–1166 0.2429 Holborn and Curtis
20–800 68–1472 0.2430 Holborn and Curtis
0–200 32– 392 0.2389 Wiedemann
90 13.851 .072197 240 17.631 .056718 550 25.444 .039302
95 13.977 .071546 250 17.883 .055919 575 26.074 .038352
100 14.103 .070907 260 18.135 .055142 600 26.704 .037448
110 14.355 .069662 270 18.387 .054386 650 27.964 .035760
120 14.607 .068460 280 18.639 .053651 700 29.224 .034219
130 14.859 .067299 290 18.891 .052935 750 30.484 .032804
140 15.111 .066177 300 19.143 .052238 800 31.744 .031502
150 15.363 .065092 320 19.647 .050898 850 33.004 .030299
[Pg 148]
Example: Required the volume of air in cubic feet under 60.3 pounds gauge pressure per square inch at
115 degrees Fahrenheit.
P = 144 (14.7 + 60.3) = 10,800.
T = 115 + 460 = 575 degrees.
53.33 × 575
Hence v = –––––––––––––––––––– = 2.84 cubic feet, and
10,800
1 1
Weight per cubic foot = –––– = –––––––– = 0.352 pounds.
v 2.84
Table 27 gives the weights and volumes of air under atmospheric pressure at varying temperatures.
Formula ( 9 ) holds good for other gases with the change in the value of the constant as follows:
For oxygen 48.24, nitrogen 54.97, hydrogen 765.71.
The specific heat of air at constant pressure varies with its temperature. A number of determinations of
this value have been made and certain of those ordinarily accepted as most authentic are given in Table
28 .
TABLE 28
SPECIFIC HEAT OF AIR
AT CONSTANT PRESSURE AND VARIOUS TEMPERATURES
Temperature Range
Specific Heat Authority
Degrees Centigrade Degrees Fahrenheit
-30– 10 -22– 50 0.2377 Regnault
0–100 32– 212 0.2374 Regnault
0–200 32– 392 0.2375 Regnault
20–440 68– 824 0.2366 Holborn and Curtis
20–630 68–1166 0.2429 Holborn and Curtis
20–800 68–1472 0.2430 Holborn and Curtis
0–200 32– 392 0.2389 Wiedemann
Page 201
This value is of particular importance in waste heat work and it is regrettable that there is such a
variation in the different experiments. Mallard and Le Chatelier determined values considerably higher
than any given in Table 28 . All things considered in view of the discrepancy of the values given, there
appears to be as much ground for the use of a constant value for the specific heat of air at any
temperature as for a variable value. Where this value is used throughout this book, it has been taken as
0.24.
Air may carry a considerable quantity of water vapor, which is frequently 3 per cent of the total
weight. This fact is of importance in problems relating to heating drying and the compressing of air.
Table 29 gives the amount of vapor required to saturate air at different temperatures, its weight,
expansive force, etc., and contains sufficient information for solving practically all problems of this
sort that may arise.
[Pg 149]
TABLE 29
WEIGHTS OF AIR, VAPOR OF WATER, AND SATURATED MIXTURES OF AIR AND VAPOR
AT DIFFERENT TEMPERATURES,
UNDER THE ORDINARY ATMOSPHERIC PRESSURE OF 29.921 INCHES OF MERCURY
Mixtures of Air Saturated with Vapor Cubic
Feet of
Volume Weight of Cubic Foot Weight Vapor
of Dry Elastic of the Mixture of Air Weight of Dry from
of
Air at Force of and Vapor Air One
Different Weight the Air Vapor Pound
Mixed
Mixed
Temper- of Cubic in the with of
atures, Foot of Mixture with Water
Total One One
the Dry Air Elastic of Air Weight Weight Weight Pound at its
Temper- Volume at the Force of and of the Pound own
of the of of
Vapor of Air,
ature at 32 Different Vapor in Vapor in Air in Mixture in Vapor, Pressure
Degrees Degrees Temper- Inches of Inches Pounds in in Pounds in in
Fahr- being atures Mercury of Pounds Pounds Column
Pounds
enheit 1.000 Pounds (Regnault) Mercury 4
1 2 3 4 5 6 7 8 9 10 11
0 .935 .0864 .044 29.877 .0863 .000079 .086379 .000921092.4 …
12 .960 .0842 .074 29.849 .0840 .000130 .084130 .00155 646.1 …
22 .980 .0824 .118 29.803 .0821 .000202 .082302 .00245 406.4 …
32 1.000 .0807 .181 29.740 .0802 .000304 .080504 .00379 263.81 3289
42 1.020 .0791 .267 29.654 .0784 .000440 .078840 .00561 178.18 2252
52 1.041 .0776 .388 29.533 .0766 .000627 .077227 .00810 122.17 1595
62 1.061 .0761 .556 29.365 .0747 .000881 .075581 .01179 84.79 1135
72 1.082 .0747 .785 29.136 .0727 .001221 .073921 .01680 59.54 819
82 1.102 .0733 1.092 28.829 .0706 .001667 .072267 .02361 42.35 600
92 1.122 .0720 1.501 28.420 .0684 .002250 .070717 .03289 30.40 444
102 1.143 .0707 2.036 27.885 .0659 .002997 .068897 .04547 21.98 334
112 1.163 .0694 2.731 27.190 .0631 .003946 .067046 .06253 15.99 253
122 1.184 .0682 3.621 26.300 .0599 .005142 .065042 .08584 11.65 194
132 1.204 .0671 4.752 25.169 .0564 .006639 .063039 .11771 8.49 151
variation in the different experiments. Mallard and Le Chatelier determined values considerably higher
than any given in Table 28 . All things considered in view of the discrepancy of the values given, there
appears to be as much ground for the use of a constant value for the specific heat of air at any
temperature as for a variable value. Where this value is used throughout this book, it has been taken as
0.24.
Air may carry a considerable quantity of water vapor, which is frequently 3 per cent of the total
weight. This fact is of importance in problems relating to heating drying and the compressing of air.
Table 29 gives the amount of vapor required to saturate air at different temperatures, its weight,
expansive force, etc., and contains sufficient information for solving practically all problems of this
sort that may arise.
[Pg 149]
TABLE 29
WEIGHTS OF AIR, VAPOR OF WATER, AND SATURATED MIXTURES OF AIR AND VAPOR
AT DIFFERENT TEMPERATURES,
UNDER THE ORDINARY ATMOSPHERIC PRESSURE OF 29.921 INCHES OF MERCURY
Mixtures of Air Saturated with Vapor Cubic
Feet of
Volume Weight of Cubic Foot Weight Vapor
of Dry Elastic of the Mixture of Air Weight of Dry from
of
Air at Force of and Vapor Air One
Different Weight the Air Vapor Pound
Mixed
Mixed
Temper- of Cubic in the with of
atures, Foot of Mixture with Water
Total One One
the Dry Air Elastic of Air Weight Weight Weight Pound at its
Temper- Volume at the Force of and of the Pound own
of the of of
Vapor of Air,
ature at 32 Different Vapor in Vapor in Air in Mixture in Vapor, Pressure
Degrees Degrees Temper- Inches of Inches Pounds in in Pounds in in
Fahr- being atures Mercury of Pounds Pounds Column
Pounds
enheit 1.000 Pounds (Regnault) Mercury 4
1 2 3 4 5 6 7 8 9 10 11
0 .935 .0864 .044 29.877 .0863 .000079 .086379 .000921092.4 …
12 .960 .0842 .074 29.849 .0840 .000130 .084130 .00155 646.1 …
22 .980 .0824 .118 29.803 .0821 .000202 .082302 .00245 406.4 …
32 1.000 .0807 .181 29.740 .0802 .000304 .080504 .00379 263.81 3289
42 1.020 .0791 .267 29.654 .0784 .000440 .078840 .00561 178.18 2252
52 1.041 .0776 .388 29.533 .0766 .000627 .077227 .00810 122.17 1595
62 1.061 .0761 .556 29.365 .0747 .000881 .075581 .01179 84.79 1135
72 1.082 .0747 .785 29.136 .0727 .001221 .073921 .01680 59.54 819
82 1.102 .0733 1.092 28.829 .0706 .001667 .072267 .02361 42.35 600
92 1.122 .0720 1.501 28.420 .0684 .002250 .070717 .03289 30.40 444
102 1.143 .0707 2.036 27.885 .0659 .002997 .068897 .04547 21.98 334
112 1.163 .0694 2.731 27.190 .0631 .003946 .067046 .06253 15.99 253
122 1.184 .0682 3.621 26.300 .0599 .005142 .065042 .08584 11.65 194
132 1.204 .0671 4.752 25.169 .0564 .006639 .063039 .11771 8.49 151
Page 202
142 1.224 .0660 6.165 23.756 .0524 .008473 .060873 .16170 6.18 118
152 1.245 .0649 7.930 21.991 .0477 .010716 .058416 .22465 4.45 93.3
162 1.265 .0638 10.099 19.822 .0423 .013415 .055715 .31713 3.15 74.5
172 1.285 .0628 12.758 17.163 .0360 .016682 .052682 .46338 2.16 59.2
182 1.306 .0618 15.960 13.961 .0288 .020536 .049336 .71300 1.402 48.6
192 1.326 .0609 19.828 10.093 .0205 .025142 .045642 1.22643 .815 39.8
202 1.347 .0600 24.450 5.471 .0109 .030545 .041445 2.80230 .357 32.7
212 1.367 .0591 29.921 0.000 .0000 .036820 .036820 Infinite .000 27.1
Column 5 = barometer pressure of 29.921, minus the proportion of this due to vapor pressure from
column 4.
152 1.245 .0649 7.930 21.991 .0477 .010716 .058416 .22465 4.45 93.3
162 1.265 .0638 10.099 19.822 .0423 .013415 .055715 .31713 3.15 74.5
172 1.285 .0628 12.758 17.163 .0360 .016682 .052682 .46338 2.16 59.2
182 1.306 .0618 15.960 13.961 .0288 .020536 .049336 .71300 1.402 48.6
192 1.326 .0609 19.828 10.093 .0205 .025142 .045642 1.22643 .815 39.8
202 1.347 .0600 24.450 5.471 .0109 .030545 .041445 2.80230 .357 32.7
212 1.367 .0591 29.921 0.000 .0000 .036820 .036820 Infinite .000 27.1
Column 5 = barometer pressure of 29.921, minus the proportion of this due to vapor pressure from
column 4.
Page 203
[Pg 150]
Page 204
COMBUSTION
Combustion may be defined as the rapid chemical combination of oxygen with carbon, hydrogen and sulphur,
accompanied by the diffusion of heat and light. That portion of the substance thus combined with the oxygen is
called combustible. As used in steam engineering practice, however, the term combustible is applied to that portion
of the fuel which is dry and free from ash, thus including both oxygen and nitrogen which may be constituents of
the fuel, though not in the true sense of the term combustible.
Combustion is perfect when the combustible unites with the greatest possible amount of oxygen, as when one atom
of carbon unites with two atoms of oxygen to form carbon dioxide, CO2. The combustion is imperfect when
complete oxidation of the combustible does not occur, or where the combustible does not unite with the maximum
amount of oxygen, as when one atom of carbon unites with one atom of oxygen to form carbon monoxide, CO,
which may be further burned to carbon dioxide.
Kindling Point—Before a combustible can unite with oxygen and combustion takes place, its temperature must
first be raised to the ignition or kindling point, and a sufficient time must be allowed for the completion of the
combustion before the temperature of the gases is lowered below that point. Table 30, by Stromeyer, gives the
approximate kindling temperatures of different fuels.
TABLE 30 Combustibles—The principal combustibles in coal and other fuels are
carbon, hydrogen and sulphur, occurring in varying proportions and
KINDLING TEMPERATURE OF combinations.
VARIOUS FUELS
Degrees Carbon is by far the most abundant as is indicated in the chapters on fuels.
Fahrenheit
Hydrogen in a free state occurs in small quantities in some fuels, but is
Lignite Dust 300
usually found in combination with carbon, in the form of hydrocarbons. The
Dried Peat 435 density of hydrogen is 0.0696 (Air = 1) and its weight per cubic foot, at 32
Sulphur 470 degrees Fahrenheit and under atmospheric pressure, is 0.005621 pounds.
Anthracite Dust 570
Coal 600 Sulphur is found in most coals and some oils. It is usually present in
Coke Red Heat combined form, either as sulphide of iron or sulphate of lime; in the latter
Anthracite Red Heat, 750 form it has no heat value. Its presence in fuel is objectionable because of its
Carbon MonoxideRed Heat, 1211 tendency to aid in the formation of clinkers, and the gases from its
Hydrogen 1030 or 1290 combustion, when in the presence of moisture, may cause corrosion.
Nitrogen is drawn into the furnace with the air. Its density is 0.9673 (Air =
1); its weight, at 32 degrees Fahrenheit and under atmospheric pressure, is 0.07829 pounds per cubic foot; each
pound of air at atmospheric pressure contains 0.7685 pounds of nitrogen, and one pound of nitrogen is contained in
1.301 pounds of air.
Nitrogen performs no useful office in combustion and passes through the furnace without change. It dilutes the air,
absorbs heat, reduces the temperature of the products of combustion, and is the chief source of heat losses in
furnaces.
[Pg 151]
Calorific Value—Each combustible element of gas will combine with oxygen in certain definite proportions and
will generate a definite amount of heat, measured in B. t. u. This definite amount of heat per pound liberated by
perfect combustion is termed the calorific value of that substance. Table 31, gives certain data on the reactions and
results of combustion for elementary combustibles and several compounds.
TABLE 31
Combustion may be defined as the rapid chemical combination of oxygen with carbon, hydrogen and sulphur,
accompanied by the diffusion of heat and light. That portion of the substance thus combined with the oxygen is
called combustible. As used in steam engineering practice, however, the term combustible is applied to that portion
of the fuel which is dry and free from ash, thus including both oxygen and nitrogen which may be constituents of
the fuel, though not in the true sense of the term combustible.
Combustion is perfect when the combustible unites with the greatest possible amount of oxygen, as when one atom
of carbon unites with two atoms of oxygen to form carbon dioxide, CO2. The combustion is imperfect when
complete oxidation of the combustible does not occur, or where the combustible does not unite with the maximum
amount of oxygen, as when one atom of carbon unites with one atom of oxygen to form carbon monoxide, CO,
which may be further burned to carbon dioxide.
Kindling Point—Before a combustible can unite with oxygen and combustion takes place, its temperature must
first be raised to the ignition or kindling point, and a sufficient time must be allowed for the completion of the
combustion before the temperature of the gases is lowered below that point. Table 30, by Stromeyer, gives the
approximate kindling temperatures of different fuels.
TABLE 30 Combustibles—The principal combustibles in coal and other fuels are
carbon, hydrogen and sulphur, occurring in varying proportions and
KINDLING TEMPERATURE OF combinations.
VARIOUS FUELS
Degrees Carbon is by far the most abundant as is indicated in the chapters on fuels.
Fahrenheit
Hydrogen in a free state occurs in small quantities in some fuels, but is
Lignite Dust 300
usually found in combination with carbon, in the form of hydrocarbons. The
Dried Peat 435 density of hydrogen is 0.0696 (Air = 1) and its weight per cubic foot, at 32
Sulphur 470 degrees Fahrenheit and under atmospheric pressure, is 0.005621 pounds.
Anthracite Dust 570
Coal 600 Sulphur is found in most coals and some oils. It is usually present in
Coke Red Heat combined form, either as sulphide of iron or sulphate of lime; in the latter
Anthracite Red Heat, 750 form it has no heat value. Its presence in fuel is objectionable because of its
Carbon MonoxideRed Heat, 1211 tendency to aid in the formation of clinkers, and the gases from its
Hydrogen 1030 or 1290 combustion, when in the presence of moisture, may cause corrosion.
Nitrogen is drawn into the furnace with the air. Its density is 0.9673 (Air =
1); its weight, at 32 degrees Fahrenheit and under atmospheric pressure, is 0.07829 pounds per cubic foot; each
pound of air at atmospheric pressure contains 0.7685 pounds of nitrogen, and one pound of nitrogen is contained in
1.301 pounds of air.
Nitrogen performs no useful office in combustion and passes through the furnace without change. It dilutes the air,
absorbs heat, reduces the temperature of the products of combustion, and is the chief source of heat losses in
furnaces.
[Pg 151]
Calorific Value—Each combustible element of gas will combine with oxygen in certain definite proportions and
will generate a definite amount of heat, measured in B. t. u. This definite amount of heat per pound liberated by
perfect combustion is termed the calorific value of that substance. Table 31, gives certain data on the reactions and
results of combustion for elementary combustibles and several compounds.
TABLE 31
Page 205
OXYGEN AND AIR REQUIRED FOR COMBUSTION
AT 32 DEGREES AND 29.92 INCHES
BY WEIGHT
1 2 3 4 5 6 7 8 9 10
Nitrogen Gaseous
Oxygen per Air per Product per Hea
Oxidizable per Pound of Pound of Pound of Value
Substance Atomic or Pound of Column 1. Column 1. Column 1[25] Pound
or Chemical Combining Chemical Product of Column 1 3.32[23] × 4.32[24] × + Column 8 Colum
Combustible Symbol Weight Reaction Combustion Pounds O Pounds O Pounds Pounds B. t.
C+2O = Carbon
Carbon C 12 2.667 8.85 11.52 12.52 1460
CO2 Dioxide
Carbon
Carbon C 12 C+O = CO 1.333 4.43 5.76 6.76 445
Monoxide
Carbon CO+O = Carbon
CO 28 .571 1.90 2.47 3.47 1015
Monoxide CO2 Dioxide
H+O =
Hydrogen H 12 Water 8 26.56 34.56 35.56 6200
H 2O
Carbon
CH4+4O =
Methane CH4 16 Dioxide and 4 13.28 17.28 18.28 2355
CO2+2H2O
Water
S+2O = Sulphur
Sulphur S 32 1 3.32 4.32 5.32 405
SO2 Dioxide
BY VOLUME
1 2 11 12 13 14 15 16 17 18
Volume Volume
per Volume Volume of Gas p
Pound of of Volume of Nitrogen pound
Volumes of Column 1 Oxygen Products of per Pound Colum
Volumes of Oxygen Volumes in per Combustion of =
Oxidizable Column 1 Combining of Gaseous Pound of per Pound Column 1. Column
Substance Entering with Product Form Column 1 of 3.782[26] × ÷
or Chemical Combination Column 11 Formed Cubic Cubic Column 1 Column 15 Column
Combustible Symbol Volume Volume Volume Feet Feet Cubic Feet Cubic Feet Cubic F
Carbon C 1C 2 2CO2 14.95 29.89 29.89 112.98 142.8
Carbon C 1C 1 2CO 14.95 14.95 29.89 56.49 86.3
Carbon
CO 2CO 1 2CO2 12.80 6.40 12.80 24.20 37.0
Monoxide
Hydrogen H 2H 1 2H2O 179.32 89.66 179.32 339.09 518.4
1CO2
Methane CH4 1C4H 4 22.41 44.83 67.34 169.55 236.8
2H2O
Sulphur S 1S 2 1SO2 5.60 11.21 11.21 42.39 53.6
It will be seen from this table that a pound of carbon will unite with 22⁄3 pounds of oxygen to form carbon dioxide,
and will evolve 14,600 B. t. u. As an intermediate step, a pound of carbon may unite with 11⁄3 pounds of oxygen to
form carbon monoxide and evolve 4450 B. t. u., but in its further conversion to CO2 it would unite with an
additional 11⁄3 times its weight of oxygen and evolve the remaining 10,150 B. t. u. [Pg 152] When a pound of CO
burns to CO2, however, only 4350 B. t. u. are evolved since the pound of CO contains but 3⁄7 pound carbon.
Air Required for Combustion—It has already been shown that each combustible element in fuel will unite with a
definite amount of oxygen. With the ultimate analysis of the fuel known, in connection with Table 31, the
theoretical amount of air required for combustion may be readily calculated.
Let the ultimate analysis be as follows:
AT 32 DEGREES AND 29.92 INCHES
BY WEIGHT
1 2 3 4 5 6 7 8 9 10
Nitrogen Gaseous
Oxygen per Air per Product per Hea
Oxidizable per Pound of Pound of Pound of Value
Substance Atomic or Pound of Column 1. Column 1. Column 1[25] Pound
or Chemical Combining Chemical Product of Column 1 3.32[23] × 4.32[24] × + Column 8 Colum
Combustible Symbol Weight Reaction Combustion Pounds O Pounds O Pounds Pounds B. t.
C+2O = Carbon
Carbon C 12 2.667 8.85 11.52 12.52 1460
CO2 Dioxide
Carbon
Carbon C 12 C+O = CO 1.333 4.43 5.76 6.76 445
Monoxide
Carbon CO+O = Carbon
CO 28 .571 1.90 2.47 3.47 1015
Monoxide CO2 Dioxide
H+O =
Hydrogen H 12 Water 8 26.56 34.56 35.56 6200
H 2O
Carbon
CH4+4O =
Methane CH4 16 Dioxide and 4 13.28 17.28 18.28 2355
CO2+2H2O
Water
S+2O = Sulphur
Sulphur S 32 1 3.32 4.32 5.32 405
SO2 Dioxide
BY VOLUME
1 2 11 12 13 14 15 16 17 18
Volume Volume
per Volume Volume of Gas p
Pound of of Volume of Nitrogen pound
Volumes of Column 1 Oxygen Products of per Pound Colum
Volumes of Oxygen Volumes in per Combustion of =
Oxidizable Column 1 Combining of Gaseous Pound of per Pound Column 1. Column
Substance Entering with Product Form Column 1 of 3.782[26] × ÷
or Chemical Combination Column 11 Formed Cubic Cubic Column 1 Column 15 Column
Combustible Symbol Volume Volume Volume Feet Feet Cubic Feet Cubic Feet Cubic F
Carbon C 1C 2 2CO2 14.95 29.89 29.89 112.98 142.8
Carbon C 1C 1 2CO 14.95 14.95 29.89 56.49 86.3
Carbon
CO 2CO 1 2CO2 12.80 6.40 12.80 24.20 37.0
Monoxide
Hydrogen H 2H 1 2H2O 179.32 89.66 179.32 339.09 518.4
1CO2
Methane CH4 1C4H 4 22.41 44.83 67.34 169.55 236.8
2H2O
Sulphur S 1S 2 1SO2 5.60 11.21 11.21 42.39 53.6
It will be seen from this table that a pound of carbon will unite with 22⁄3 pounds of oxygen to form carbon dioxide,
and will evolve 14,600 B. t. u. As an intermediate step, a pound of carbon may unite with 11⁄3 pounds of oxygen to
form carbon monoxide and evolve 4450 B. t. u., but in its further conversion to CO2 it would unite with an
additional 11⁄3 times its weight of oxygen and evolve the remaining 10,150 B. t. u. [Pg 152] When a pound of CO
burns to CO2, however, only 4350 B. t. u. are evolved since the pound of CO contains but 3⁄7 pound carbon.
Air Required for Combustion—It has already been shown that each combustible element in fuel will unite with a
definite amount of oxygen. With the ultimate analysis of the fuel known, in connection with Table 31, the
theoretical amount of air required for combustion may be readily calculated.
Let the ultimate analysis be as follows:
Page 206
Per Cent
Carbon 74.79
Hydrogen 4.98
Oxygen 6.42
Nitrogen 1.20
Sulphur 3.24
Water 1.55
Ash 7.82
–––––
100.00
When complete combustion takes place, as already pointed out, the carbon in the fuel unites with a definite amount
of oxygen to form CO2. The hydrogen, either in a free or combined state, will unite with oxygen to form water
vapor, H2O. Not all of the hydrogen shown in a fuel analysis, however, is available for the production of heat, as a
portion of it is already united with the oxygen shown by the analysis in the form of water, H2O. Since the atomic
weights of H and O are respectively 1 and 16, the weight of the combined hydrogen will be 1⁄8 of the weight of the
oxygen, and the hydrogen available for combustion will be H - 1⁄8 O. In complete combustion of the sulphur,
sulphur dioxide SO2 is formed, which in solution in water forms sulphuric acid.
Expressed numerically, the theoretical amount of air for the above analysis is as follows:
0.7479 C × 22⁄3 = 1.9944 O needed
0.0642
( )
0.0498 - –––––––––––– H × 8 = 0.3262 O needed
8
0.0324 S × 1 = 0.0324 O needed
–––––––––––
Total = 2.3530 O needed
One pound of oxygen is contained in 4.32 pounds of air.
The total air needed per pound of coal, therefore, will be 2.353 × 4.32 = 10.165.
The weight of combustible per pound of fuel is .7479 + .0418[27] + .0324 + .012 = .83 pounds, and the air
theoretically required per pound of combustible is 10.165 ÷ .83 = 12.2 pounds.
The above is equivalent to computing the theoretical amount of air required per pound of fuel by the formula:
O
(
Weight per pound = 11.52 C + 34.56 H - –––– + 4.32 S
8
) (10)
where C, H, O and S are proportional parts by weight of carbon, hydrogen, oxygen and sulphur by ultimate
analysis.
[Pg 153]
In practice it is impossible to obtain perfect combustion with the theoretical amount of air, and an excess may be
required, amounting to sometimes double the theoretical supply, depending upon the nature of the fuel to be
burned and the method of burning it. The reason for this is that it is impossible to bring each particle of oxygen in
the air into intimate contact with the particles in the fuel that are to be oxidized, due not only to the dilution of the
oxygen in the air by nitrogen, but because of such factors as the irregular thickness of the fire, the varying
resistance to the passage of the air through the fire in separate parts on account of ash, clinker, etc. Where the
difficulties of drawing air uniformly through a fuel bed are eliminated, as in the case of burning oil fuel or gas, the
Carbon 74.79
Hydrogen 4.98
Oxygen 6.42
Nitrogen 1.20
Sulphur 3.24
Water 1.55
Ash 7.82
–––––
100.00
When complete combustion takes place, as already pointed out, the carbon in the fuel unites with a definite amount
of oxygen to form CO2. The hydrogen, either in a free or combined state, will unite with oxygen to form water
vapor, H2O. Not all of the hydrogen shown in a fuel analysis, however, is available for the production of heat, as a
portion of it is already united with the oxygen shown by the analysis in the form of water, H2O. Since the atomic
weights of H and O are respectively 1 and 16, the weight of the combined hydrogen will be 1⁄8 of the weight of the
oxygen, and the hydrogen available for combustion will be H - 1⁄8 O. In complete combustion of the sulphur,
sulphur dioxide SO2 is formed, which in solution in water forms sulphuric acid.
Expressed numerically, the theoretical amount of air for the above analysis is as follows:
0.7479 C × 22⁄3 = 1.9944 O needed
0.0642
( )
0.0498 - –––––––––––– H × 8 = 0.3262 O needed
8
0.0324 S × 1 = 0.0324 O needed
–––––––––––
Total = 2.3530 O needed
One pound of oxygen is contained in 4.32 pounds of air.
The total air needed per pound of coal, therefore, will be 2.353 × 4.32 = 10.165.
The weight of combustible per pound of fuel is .7479 + .0418[27] + .0324 + .012 = .83 pounds, and the air
theoretically required per pound of combustible is 10.165 ÷ .83 = 12.2 pounds.
The above is equivalent to computing the theoretical amount of air required per pound of fuel by the formula:
O
(
Weight per pound = 11.52 C + 34.56 H - –––– + 4.32 S
8
) (10)
where C, H, O and S are proportional parts by weight of carbon, hydrogen, oxygen and sulphur by ultimate
analysis.
[Pg 153]
In practice it is impossible to obtain perfect combustion with the theoretical amount of air, and an excess may be
required, amounting to sometimes double the theoretical supply, depending upon the nature of the fuel to be
burned and the method of burning it. The reason for this is that it is impossible to bring each particle of oxygen in
the air into intimate contact with the particles in the fuel that are to be oxidized, due not only to the dilution of the
oxygen in the air by nitrogen, but because of such factors as the irregular thickness of the fire, the varying
resistance to the passage of the air through the fire in separate parts on account of ash, clinker, etc. Where the
difficulties of drawing air uniformly through a fuel bed are eliminated, as in the case of burning oil fuel or gas, the
Page 207
air supply may be materially less than would be required for coal. Experiment has shown that coal will usually
require 50 per cent more than the theoretical net calculated amount of air, or about 18 pounds per pound of fuel
either under natural or forced draft, though this amount may vary widely with the type of furnace, the nature of the
coal, and the method of firing. If less than this amount of air is supplied, the carbon burns to monoxide instead of
dioxide and its full heat value is not developed.
TABLE 32 An excess of air is also a source of waste, as
the products of combustion will be diluted
CALCULATED THEORETICAL AMOUNT OF AIR and carry off an excessive amount of heat in
REQUIRED PER POUND OF VARIOUS FUELS the chimney gases, or the air will so lower the
Weight of Constituents in One Air Required temperature of the furnace gases as to delay
Pound Dry Fuel per Pound the combustion to an extent that will cause
Fuel carbon monoxide to pass off unburned from
Carbon Hydrogen Oxygen of Fuel
Per Cent Per Cent Per Cent Pounds the furnace. A sufficient amount of carbon
Coke 94.0 … … 10.8 monoxide in the gases may cause the action
known as secondary combustion, by igniting
Anthracite Coal 91.5 3.5 2.6 11.7
or mingling with air after leaving the furnace
Bituminous Coal 87.0 5.0 4.0 11.6 or in the flues or stack. Such secondary
Lignite 70.0 5.0 20.0 8.9 combustion which takes place either within
Wood 50.0 6.0 43.5 6.0 the setting after leaving the furnace or in the
Oil 85.0 3.0 1.0 14.3 flues or stack always leads to a loss of
efficiency and, in some instances, leads to
overheating of the flues and stack.
Table 32 gives the theoretical amount of air required for various fuels calculated from formula (10) assuming the
analyses of the fuels given in the table.
The process of combustion of different fuels and the effect of variation in the air supply for their combustion is
treated in detail in the chapters dealing with the various fuels.
[Pg 154]
4064 HORSE-POWER Installation of Babcock & Wilcox Boilers and Superheaters, Equipped with Babcock
& Wilcox Chain Grate Stokers, at the Cosmopolitan Electric Co., Chicago, Ill.
FOOTNOTES
require 50 per cent more than the theoretical net calculated amount of air, or about 18 pounds per pound of fuel
either under natural or forced draft, though this amount may vary widely with the type of furnace, the nature of the
coal, and the method of firing. If less than this amount of air is supplied, the carbon burns to monoxide instead of
dioxide and its full heat value is not developed.
TABLE 32 An excess of air is also a source of waste, as
the products of combustion will be diluted
CALCULATED THEORETICAL AMOUNT OF AIR and carry off an excessive amount of heat in
REQUIRED PER POUND OF VARIOUS FUELS the chimney gases, or the air will so lower the
Weight of Constituents in One Air Required temperature of the furnace gases as to delay
Pound Dry Fuel per Pound the combustion to an extent that will cause
Fuel carbon monoxide to pass off unburned from
Carbon Hydrogen Oxygen of Fuel
Per Cent Per Cent Per Cent Pounds the furnace. A sufficient amount of carbon
Coke 94.0 … … 10.8 monoxide in the gases may cause the action
known as secondary combustion, by igniting
Anthracite Coal 91.5 3.5 2.6 11.7
or mingling with air after leaving the furnace
Bituminous Coal 87.0 5.0 4.0 11.6 or in the flues or stack. Such secondary
Lignite 70.0 5.0 20.0 8.9 combustion which takes place either within
Wood 50.0 6.0 43.5 6.0 the setting after leaving the furnace or in the
Oil 85.0 3.0 1.0 14.3 flues or stack always leads to a loss of
efficiency and, in some instances, leads to
overheating of the flues and stack.
Table 32 gives the theoretical amount of air required for various fuels calculated from formula (10) assuming the
analyses of the fuels given in the table.
The process of combustion of different fuels and the effect of variation in the air supply for their combustion is
treated in detail in the chapters dealing with the various fuels.
[Pg 154]
4064 HORSE-POWER Installation of Babcock & Wilcox Boilers and Superheaters, Equipped with Babcock
& Wilcox Chain Grate Stokers, at the Cosmopolitan Electric Co., Chicago, Ill.
FOOTNOTES
Page 208
[23] Ratio by weight of O to N in air.
[24] 4.32 pounds of air contains one pound of O.
[25] Per pound of C in the CO.
[26] Ratio by volume of O to N in air.
[27] Available hydrogen.
[24] 4.32 pounds of air contains one pound of O.
[25] Per pound of C in the CO.
[26] Ratio by volume of O to N in air.
[27] Available hydrogen.
Page 209
[Pg 155]
Page 210
ANALYSIS OF FLUE GASES
The object of a flue gas analysis is the determination of the completeness of
the combustion of the carbon in the fuel, and the amount and distribution of
the heat losses due to incomplete combustion. The quantities actually
determined by an analysis are the relative proportions by volume, of carbon
dioxide (CO 2 ), oxygen (O), and carbon monoxide (CO), the determinations
being made in this order.
The variations of the percentages of these gases in an analysis is best
illustrated in the consideration of the complete combustion of pure carbon, a
pound of which requires 2.67 pounds of oxygen, [28] or 32 cubic feet at 60
degrees Fahrenheit. The gaseous product of such combustion will occupy,
when cooled, the same volume as the oxygen, namely, 32 cubic feet. The air
supplied for the combustion is made up of 20.91 per cent oxygen and 79.09
per cent nitrogen by volume. The carbon united with the oxygen in the form
of carbon dioxide will have the same volume as the oxygen in the air
originally supplied. The volume of the nitrogen when cooled will be the
same as in the air supplied, as it undergoes no change. Hence for complete
combustion of one pound of carbon, where no excess of air is supplied, an
analysis of the products of combustion will show the following percentages
by volume:
Actual Volume
Per Cent
for One Pound Carbon
by Volume
Cubic Feet
Carbon Dioxide 32 = 20.91
Oxygen 0 = 0.00
Nitrogen 121 = 79.09
–––––– –––––––––––
Air required for one pound Carbon 153 = 100.00
For 50 per cent excess air the volume will be as follows:
153 × 1½ = 229.5 cubic feet of air per pound of carbon.
The object of a flue gas analysis is the determination of the completeness of
the combustion of the carbon in the fuel, and the amount and distribution of
the heat losses due to incomplete combustion. The quantities actually
determined by an analysis are the relative proportions by volume, of carbon
dioxide (CO 2 ), oxygen (O), and carbon monoxide (CO), the determinations
being made in this order.
The variations of the percentages of these gases in an analysis is best
illustrated in the consideration of the complete combustion of pure carbon, a
pound of which requires 2.67 pounds of oxygen, [28] or 32 cubic feet at 60
degrees Fahrenheit. The gaseous product of such combustion will occupy,
when cooled, the same volume as the oxygen, namely, 32 cubic feet. The air
supplied for the combustion is made up of 20.91 per cent oxygen and 79.09
per cent nitrogen by volume. The carbon united with the oxygen in the form
of carbon dioxide will have the same volume as the oxygen in the air
originally supplied. The volume of the nitrogen when cooled will be the
same as in the air supplied, as it undergoes no change. Hence for complete
combustion of one pound of carbon, where no excess of air is supplied, an
analysis of the products of combustion will show the following percentages
by volume:
Actual Volume
Per Cent
for One Pound Carbon
by Volume
Cubic Feet
Carbon Dioxide 32 = 20.91
Oxygen 0 = 0.00
Nitrogen 121 = 79.09
–––––– –––––––––––
Air required for one pound Carbon 153 = 100.00
For 50 per cent excess air the volume will be as follows:
153 × 1½ = 229.5 cubic feet of air per pound of carbon.
Page 211
Actual Volume
Per Cent
for One Pound
by
Carbon
Volume
Cubic Feet
Carbon Dioxide 32 = 13.91
Oxygen 16 = 7.00 } = 20.91
cent
per
Nitrogen 181.5 = 79.09
–––––––––– –––––––––––
Air required for one pound
229.5 = 100.00
Carbon
For 100 per cent excess air the volume will be as follows:
153 × 2 = 306 cubic feet of air per pound of carbon.
Actual Volume
Per Cent
for One Pound
by
Carbon
Volume
Cubic Feet
Carbon Dioxide 32 = 10.45 20.91 per
Oxygen 32 = 10.45
= }
cent
Nitrogen 242 = 79.09
–––––– –––––––––––
Air required for one pound
306 = 100.00
Carbon
In each case the volume of oxygen which combines with the carbon is equal
to (cubic feet of air × 20.91 per cent)—32 cubic feet.
[Pg 156]
It will be seen that no matter what the excess of air supplied, the actual
amount of carbon dioxide per pound of carbon remains the same, while the
percentage by volume decreases as the excess of air increases. The actual
volume of oxygen and the percentage by volume increases with the excess of
air, and the percentage of oxygen is, therefore, an indication of the amount
of excess air. In each case the sum of the percentages of CO 2 and O is the
same, 20.9. Although the volume of nitrogen increases with the excess of air,
Per Cent
for One Pound
by
Carbon
Volume
Cubic Feet
Carbon Dioxide 32 = 13.91
Oxygen 16 = 7.00 } = 20.91
cent
per
Nitrogen 181.5 = 79.09
–––––––––– –––––––––––
Air required for one pound
229.5 = 100.00
Carbon
For 100 per cent excess air the volume will be as follows:
153 × 2 = 306 cubic feet of air per pound of carbon.
Actual Volume
Per Cent
for One Pound
by
Carbon
Volume
Cubic Feet
Carbon Dioxide 32 = 10.45 20.91 per
Oxygen 32 = 10.45
= }
cent
Nitrogen 242 = 79.09
–––––– –––––––––––
Air required for one pound
306 = 100.00
Carbon
In each case the volume of oxygen which combines with the carbon is equal
to (cubic feet of air × 20.91 per cent)—32 cubic feet.
[Pg 156]
It will be seen that no matter what the excess of air supplied, the actual
amount of carbon dioxide per pound of carbon remains the same, while the
percentage by volume decreases as the excess of air increases. The actual
volume of oxygen and the percentage by volume increases with the excess of
air, and the percentage of oxygen is, therefore, an indication of the amount
of excess air. In each case the sum of the percentages of CO 2 and O is the
same, 20.9. Although the volume of nitrogen increases with the excess of air,
Page 212
its percentage by volume remains the same as it undergoes no change while
combustion takes place; its percentage for any amount of air excess,
therefore, will be the same after combustion as before, if cooled to the same
temperature. It must be borne in mind that the above conditions hold only for
the perfect combustion of a pound of pure carbon.
Carbon monoxide (CO) produced by the imperfect combustion of carbon,
will occupy twice the volume of the oxygen entering into its composition
and will increase the volume of the flue gases over that of the air supplied
for combustion in the proportion of
100 + ½ the per cent CO
1 to –––––––––––––––––––––––––––––––––––––––
100
When pure carbon is the fuel, the sum of the percentages by volume of
carbon dioxide, oxygen and one-half of the carbon monoxide, must be in the
same ratio to the nitrogen in the flue gases as is the oxygen to the nitrogen in
the air supplied, that is, 20.91 to 79.09. When burning coal, however, the
percentage of nitrogen is obtained by subtracting the sum of the percentages
by volume of the other gases from 100. Thus if an analysis shows 12.5 per
cent CO 2 , 6.5 per cent O, and 0.6 per cent CO, the percentage of nitrogen
which ordinarily is the only other constituent of the gas which need be
considered, is found as follows:
100 - (12.5 + 6.5 + 0.6) = 80.4 per cent.
The action of the hydrogen in the volatile constituents of the fuel is to
increase the apparent percentage of the nitrogen in the flue gases. This is due
to the fact that the water vapor formed by the combustion of the hydrogen
will condense at a temperature at which the analysis is made, while the
nitrogen which accompanied the oxygen with which the hydrogen originally
combined maintains its gaseous form and passes into the sampling apparatus
with the other gases. For this reason coals containing high percentages of
volatile matter will produce a larger quantity of water vapor, and thus
increase the apparent percentage of nitrogen.
combustion takes place; its percentage for any amount of air excess,
therefore, will be the same after combustion as before, if cooled to the same
temperature. It must be borne in mind that the above conditions hold only for
the perfect combustion of a pound of pure carbon.
Carbon monoxide (CO) produced by the imperfect combustion of carbon,
will occupy twice the volume of the oxygen entering into its composition
and will increase the volume of the flue gases over that of the air supplied
for combustion in the proportion of
100 + ½ the per cent CO
1 to –––––––––––––––––––––––––––––––––––––––
100
When pure carbon is the fuel, the sum of the percentages by volume of
carbon dioxide, oxygen and one-half of the carbon monoxide, must be in the
same ratio to the nitrogen in the flue gases as is the oxygen to the nitrogen in
the air supplied, that is, 20.91 to 79.09. When burning coal, however, the
percentage of nitrogen is obtained by subtracting the sum of the percentages
by volume of the other gases from 100. Thus if an analysis shows 12.5 per
cent CO 2 , 6.5 per cent O, and 0.6 per cent CO, the percentage of nitrogen
which ordinarily is the only other constituent of the gas which need be
considered, is found as follows:
100 - (12.5 + 6.5 + 0.6) = 80.4 per cent.
The action of the hydrogen in the volatile constituents of the fuel is to
increase the apparent percentage of the nitrogen in the flue gases. This is due
to the fact that the water vapor formed by the combustion of the hydrogen
will condense at a temperature at which the analysis is made, while the
nitrogen which accompanied the oxygen with which the hydrogen originally
combined maintains its gaseous form and passes into the sampling apparatus
with the other gases. For this reason coals containing high percentages of
volatile matter will produce a larger quantity of water vapor, and thus
increase the apparent percentage of nitrogen.
Page 213
Air Required and Supplied —When the ultimate analysis of a fuel is known,
the air required for complete combustion with no excess can be found as
shown in the chapter on combustion, or from the following approximate
formula:
C O S
Pounds of air required per - (
pound of fuel
= 34.56 ( 3 + (H 8 ) + 8 )
–––– –––– ––––
[29]
11 )
where C, H and O equal the percentage by weight of carbon, hydrogen and
oxygen in the fuel divided by 100.
[Pg 157]
When the flue gas analysis is known, the total, amount of air supplied is:
N
Pounds of air supplied per ( 12
pound of fuel
= 3.036 ( CO + ) × C
–––––––––––––––––
2
[30]
)
CO
where N, CO 2 and CO are the percentages by volume of nitrogen, carbon
dioxide and carbon monoxide in the flue gases, and C the percentage by
weight of carbon which is burned from the fuel and passes up the stack as
flue gas. This percentage of C which is burned must be distinguished from
the percentage of C as found by an ultimate analysis of the fuel. To find the
percentage of C which is burned, deduct from the total percentage of carbon
as found in the ultimate analysis, the percentage of unconsumed carbon
found in the ash. This latter quantity is the difference between the percentage
of ash found by an analysis and that as determined by a boiler test. It is
usually assumed that the entire combustible element in the ash is carbon,
which assumption is practically correct. Thus if the ash in a boiler test were
16 per cent and by an analysis contained 25 per cent of carbon, the
percentage of unconsumed carbon would be 16 × .25 = 4 per cent of the total
coal burned. If the coal contained by ultimate analysis 80 per cent of carbon
the percentage burned, and of which the products of combustion pass up the
chimney would be 80 - 4 = 76 per cent, which is the correct figure to use in
calculating the total amount of air supplied by formula ( 12 ).
the air required for complete combustion with no excess can be found as
shown in the chapter on combustion, or from the following approximate
formula:
C O S
Pounds of air required per - (
pound of fuel
= 34.56 ( 3 + (H 8 ) + 8 )
–––– –––– ––––
[29]
11 )
where C, H and O equal the percentage by weight of carbon, hydrogen and
oxygen in the fuel divided by 100.
[Pg 157]
When the flue gas analysis is known, the total, amount of air supplied is:
N
Pounds of air supplied per ( 12
pound of fuel
= 3.036 ( CO + ) × C
–––––––––––––––––
2
[30]
)
CO
where N, CO 2 and CO are the percentages by volume of nitrogen, carbon
dioxide and carbon monoxide in the flue gases, and C the percentage by
weight of carbon which is burned from the fuel and passes up the stack as
flue gas. This percentage of C which is burned must be distinguished from
the percentage of C as found by an ultimate analysis of the fuel. To find the
percentage of C which is burned, deduct from the total percentage of carbon
as found in the ultimate analysis, the percentage of unconsumed carbon
found in the ash. This latter quantity is the difference between the percentage
of ash found by an analysis and that as determined by a boiler test. It is
usually assumed that the entire combustible element in the ash is carbon,
which assumption is practically correct. Thus if the ash in a boiler test were
16 per cent and by an analysis contained 25 per cent of carbon, the
percentage of unconsumed carbon would be 16 × .25 = 4 per cent of the total
coal burned. If the coal contained by ultimate analysis 80 per cent of carbon
the percentage burned, and of which the products of combustion pass up the
chimney would be 80 - 4 = 76 per cent, which is the correct figure to use in
calculating the total amount of air supplied by formula ( 12 ).
Page 214
The weight of flue gases resulting from the combustion of a pound of dry
coal will be the sum of the weights of the air per pound of coal and the
combustible per pound of coal, the latter being equal to one minus the
percentage of ash as found in the boiler test. The weight of flue gases per
pound of dry fuel may, however, be computed directly from the analyses, as
shown later, and the direct computation is that ordinarily used.
The ratio of the air actually supplied per pound of fuel to that theoretically
required to burn it is:
N
3.036 ( CO + CO ) × C
–––––––––––––––––
2
––––––––––––––––––––––––––––––––––––––––––––– ( 13 )
C O
34.56 (3 + H - 8)
––– –––
in which the letters have the same significance as in formulae ( 11 ) and ( 12
).
The ratio of the air supplied per pound of combustible to the amount
theoretically required is:
N
–––––––––––––––––––––––––––––––––– ( 14 )
N - 3.782(O - ½CO)
which is derived as follows:
The N in the flue gas is the content of nitrogen in the whole amount of air
supplied. The oxygen in the flue gas is that contained in the air supplied and
which was not utilized in combustion. This oxygen was accompanied by
3.782 times its volume of nitrogen. The total amount of excess oxygen in the
flue gases is (O - ½CO); hence N - 3.782(O - ½CO) represents the nitrogen
content in the air actually required for combustion and N ÷ (N - 3.782[O -
coal will be the sum of the weights of the air per pound of coal and the
combustible per pound of coal, the latter being equal to one minus the
percentage of ash as found in the boiler test. The weight of flue gases per
pound of dry fuel may, however, be computed directly from the analyses, as
shown later, and the direct computation is that ordinarily used.
The ratio of the air actually supplied per pound of fuel to that theoretically
required to burn it is:
N
3.036 ( CO + CO ) × C
–––––––––––––––––
2
––––––––––––––––––––––––––––––––––––––––––––– ( 13 )
C O
34.56 (3 + H - 8)
––– –––
in which the letters have the same significance as in formulae ( 11 ) and ( 12
).
The ratio of the air supplied per pound of combustible to the amount
theoretically required is:
N
–––––––––––––––––––––––––––––––––– ( 14 )
N - 3.782(O - ½CO)
which is derived as follows:
The N in the flue gas is the content of nitrogen in the whole amount of air
supplied. The oxygen in the flue gas is that contained in the air supplied and
which was not utilized in combustion. This oxygen was accompanied by
3.782 times its volume of nitrogen. The total amount of excess oxygen in the
flue gases is (O - ½CO); hence N - 3.782(O - ½CO) represents the nitrogen
content in the air actually required for combustion and N ÷ (N - 3.782[O -
Page 215
½CO]) is the [Pg 158] ratio of the air supplied to that required. This ratio
minus one will be the proportion of excess air.
The heat lost in the flue gases is L = 0.24 W (T - t ) ( 15 )
Where L = B. t. u. lost per pound of fuel,
W = weight of flue gases in pounds per pound of dry coal,
T = temperature of flue gases,
t = temperature of atmosphere,
0.24 = specific heat of the flue gases.
The weight of flue gases, W, per pound of carbon can be computed directly
from the flue gas analysis from the formula:
11 CO 2 + 8 O + 7 (CO + N)
––––––––––––––––––––––––––––––––––––––––––––– ( 16 )
3 (CO 2 + CO)
where CO 2 , O, CO, and N are the percentages by volume as determined by
the flue gas analysis of carbon dioxide, oxygen, carbon monoxide and
nitrogen.
The weight of flue gas per pound of dry coal will be the weight determined
by this formula multiplied by the percentage of carbon in the coal from an
ultimate analysis.
minus one will be the proportion of excess air.
The heat lost in the flue gases is L = 0.24 W (T - t ) ( 15 )
Where L = B. t. u. lost per pound of fuel,
W = weight of flue gases in pounds per pound of dry coal,
T = temperature of flue gases,
t = temperature of atmosphere,
0.24 = specific heat of the flue gases.
The weight of flue gases, W, per pound of carbon can be computed directly
from the flue gas analysis from the formula:
11 CO 2 + 8 O + 7 (CO + N)
––––––––––––––––––––––––––––––––––––––––––––– ( 16 )
3 (CO 2 + CO)
where CO 2 , O, CO, and N are the percentages by volume as determined by
the flue gas analysis of carbon dioxide, oxygen, carbon monoxide and
nitrogen.
The weight of flue gas per pound of dry coal will be the weight determined
by this formula multiplied by the percentage of carbon in the coal from an
ultimate analysis.
Page 216
Fig. 20. Loss Due to Heat Carried Away by Chimney Gases for Varying
Percentages of Carbon Dioxide.
Based on Boiler Room Temperature = 80 Degrees Fahrenheit.
Nitrogen in Flue Gas = 80.5 Per Cent. Carbon Monoxide in Flue Gas =
0. Per Cent
Fig. 20 represents graphically the loss due to heat carried away by dry
chimney gases for varying percentages of CO 2 , and different temperatures
of exit gases.
[Pg 159]
The heat lost, due to the fact that the carbon in the fuel is not completely
burned and carbon monoxide is present in the flue gases, in B. t. u. per
pound of fuel burned is:
Percentages of Carbon Dioxide.
Based on Boiler Room Temperature = 80 Degrees Fahrenheit.
Nitrogen in Flue Gas = 80.5 Per Cent. Carbon Monoxide in Flue Gas =
0. Per Cent
Fig. 20 represents graphically the loss due to heat carried away by dry
chimney gases for varying percentages of CO 2 , and different temperatures
of exit gases.
[Pg 159]
The heat lost, due to the fact that the carbon in the fuel is not completely
burned and carbon monoxide is present in the flue gases, in B. t. u. per
pound of fuel burned is:
Page 217
CO
L' = 10,150 × ( CO + CO )
–––––––––––––––––
2
( 17 )
where, as before, CO and CO 2 are the percentages by volume in the flue
gases and C is the proportion by weight of carbon which is burned and
passes up the stack.
Fig. 21 represents graphically the loss due to such carbon in the fuel as is not
completely burned but escapes up the stack in the form of carbon monoxide.
L' = 10,150 × ( CO + CO )
–––––––––––––––––
2
( 17 )
where, as before, CO and CO 2 are the percentages by volume in the flue
gases and C is the proportion by weight of carbon which is burned and
passes up the stack.
Fig. 21 represents graphically the loss due to such carbon in the fuel as is not
completely burned but escapes up the stack in the form of carbon monoxide.
Page 218
Fig. 21. Loss Due to Unconsumed Carbon Contained in the CO in the
Flue Gases
Apparatus for Flue Gas Analysis —The Orsat apparatus, illustrated in Fig.
22, is generally used for analyzing flue gases. The burette A is graduated in
cubic centimeters up to 100, and is surrounded by a water jacket to prevent
any change in temperature from affecting the density of the gas being
analyzed.
For accurate work it is advisable to use four pipettes, B , C , D , E , the first
containing a solution of caustic potash for the absorption of carbon dioxide,
the second an alkaline solution of pyrogallol for the absorption of oxygen,
and the remaining two an acid solution of cuprous chloride for absorbing the
carbon monoxide. Each pipette contains a number of glass tubes, to which
some of the solution clings, thus facilitating [Pg 160] the absorption of the gas.
In the pipettes D and E , copper wire is placed in these tubes to re-energize
the solution as it becomes weakened. The rear half of each pipette is fitted
with a rubber bag, one of which is shown at K , to protect the solution from
the action of the air. The solution in each pipette should be drawn up to the
mark on the capillary tube.
The gas is drawn into the burette through the U-tube H , which is filled with
spun glass, or similar material, to clean the gas. To discharge any air or gas
in the apparatus, the cock G is opened to the air and the bottle F is raised
until the water in the burette reaches the 100 cubic centimeters mark. The
cock G is then turned so as to close the air opening and allow gas to be
drawn through H , the bottle F being lowered for this purpose. The gas is
drawn into the burette to a point below the zero mark, the cock G then being
opened to the air and the excess gas expelled until the level of the water in F
and in A are at the zero mark. This operation is necessary in order to obtain
the zero reading at atmospheric pressure.
The apparatus should be carefully tested for leakage as well as all
connections leading thereto. Simple tests can be made; for example: If after
the cock G is closed, the bottle F is placed on top of the frame for a short
time and again brought to the zero mark, the level of the water in A is above
the zero mark, a leak is indicated.
Flue Gases
Apparatus for Flue Gas Analysis —The Orsat apparatus, illustrated in Fig.
22, is generally used for analyzing flue gases. The burette A is graduated in
cubic centimeters up to 100, and is surrounded by a water jacket to prevent
any change in temperature from affecting the density of the gas being
analyzed.
For accurate work it is advisable to use four pipettes, B , C , D , E , the first
containing a solution of caustic potash for the absorption of carbon dioxide,
the second an alkaline solution of pyrogallol for the absorption of oxygen,
and the remaining two an acid solution of cuprous chloride for absorbing the
carbon monoxide. Each pipette contains a number of glass tubes, to which
some of the solution clings, thus facilitating [Pg 160] the absorption of the gas.
In the pipettes D and E , copper wire is placed in these tubes to re-energize
the solution as it becomes weakened. The rear half of each pipette is fitted
with a rubber bag, one of which is shown at K , to protect the solution from
the action of the air. The solution in each pipette should be drawn up to the
mark on the capillary tube.
The gas is drawn into the burette through the U-tube H , which is filled with
spun glass, or similar material, to clean the gas. To discharge any air or gas
in the apparatus, the cock G is opened to the air and the bottle F is raised
until the water in the burette reaches the 100 cubic centimeters mark. The
cock G is then turned so as to close the air opening and allow gas to be
drawn through H , the bottle F being lowered for this purpose. The gas is
drawn into the burette to a point below the zero mark, the cock G then being
opened to the air and the excess gas expelled until the level of the water in F
and in A are at the zero mark. This operation is necessary in order to obtain
the zero reading at atmospheric pressure.
The apparatus should be carefully tested for leakage as well as all
connections leading thereto. Simple tests can be made; for example: If after
the cock G is closed, the bottle F is placed on top of the frame for a short
time and again brought to the zero mark, the level of the water in A is above
the zero mark, a leak is indicated.
Page 219
Before taking a final sample for analysis, the
burette A should be filled with gas and
emptied once or twice, to make sure that all
the apparatus is filled with the new gas. The
cock G is then closed and the cock I in the
pipette B is opened and the gas driven over
into B by raising the bottle F . The gas is
drawn back into A by lowering F and when the
solution in B has reached the mark in the
capillary tube, the cock I is closed and a
reading is taken on the burette, the level of the
water in the bottle F being brought to the same
level as the water in A . The operation is
repeated until a constant reading is obtained,
the number of cubic centimeters being the
Fig. 22. Orsat Apparatus percentage of CO 2 in the flue gases.
The gas is then driven over into the pipette C
and a similar operation is carried out. The difference between the resulting
reading and the first reading gives the percentage of oxygen in the flue
gases.
The next operation is to drive the gas into the pipette D , the gas being given
a final wash in E , and then passed into the pipette C to neutralize any
hydrochloric acid fumes which may have been given off by the cuprous
chloride solution, which, especially if it be old, may give off such fumes,
thus increasing the volume of the gases and making the reading on the
burette less than the true amount.
The process must be carried out in the order named, as the pyrogallol
solution will also absorb carbon dioxide, while the cuprous chloride solution
will also absorb oxygen.
[Pg 161]
As the pressure of the gases in the flue is less than the atmospheric pressure,
they will not of themselves flow through the pipe connecting the flue to the
apparatus. The gas may be drawn into the pipe in the way already described
burette A should be filled with gas and
emptied once or twice, to make sure that all
the apparatus is filled with the new gas. The
cock G is then closed and the cock I in the
pipette B is opened and the gas driven over
into B by raising the bottle F . The gas is
drawn back into A by lowering F and when the
solution in B has reached the mark in the
capillary tube, the cock I is closed and a
reading is taken on the burette, the level of the
water in the bottle F being brought to the same
level as the water in A . The operation is
repeated until a constant reading is obtained,
the number of cubic centimeters being the
Fig. 22. Orsat Apparatus percentage of CO 2 in the flue gases.
The gas is then driven over into the pipette C
and a similar operation is carried out. The difference between the resulting
reading and the first reading gives the percentage of oxygen in the flue
gases.
The next operation is to drive the gas into the pipette D , the gas being given
a final wash in E , and then passed into the pipette C to neutralize any
hydrochloric acid fumes which may have been given off by the cuprous
chloride solution, which, especially if it be old, may give off such fumes,
thus increasing the volume of the gases and making the reading on the
burette less than the true amount.
The process must be carried out in the order named, as the pyrogallol
solution will also absorb carbon dioxide, while the cuprous chloride solution
will also absorb oxygen.
[Pg 161]
As the pressure of the gases in the flue is less than the atmospheric pressure,
they will not of themselves flow through the pipe connecting the flue to the
apparatus. The gas may be drawn into the pipe in the way already described
Page 220
for filling the apparatus, but this is a tedious method. For rapid work a
rubber bulb aspirator connected to the air outlet of the cock G will enable a
new supply of gas to be drawn into the pipe, the apparatus then being filled
as already described. Another form of aspirator draws the gas from the flue
in a constant stream, thus insuring a fresh supply for each sample.
The analysis made by the Orsat apparatus is volumetric; if the analysis by
weight is required, it can be found from the volumetric analysis as follows:
Multiply the percentages by volume by either the densities or the molecular
weight of each gas, and divide the products by the sum of all the products;
the quotients will be the percentages by weight. For most work sufficient
accuracy is secured by using the even values of the molecular weights.
The even values of the molecular weights of the gases appearing in an
analysis by an Orsat are:
Carbon Dioxide 44
Carbon Monoxide 28
Oxygen 32
Nitrogen 28
Table 33 indicates the method of converting a volumetric flue gas analysis
into an analysis by weight.
TABLE 33
CONVERSION OF A FLUE GAS ANALYSIS BY VOLUME TO ONE BY
WEIGHT
Volume
Analysis by Analysis by
Molecular times
Gas Volume Weight
Weight Molecular
Per Cent Per Cent
Weight
536.8
Carbon CO
12.2 12+(2×16) 536.8 ––––––––––– = 17.7
Dioxide 2 3022.8
Carbon CO .4 12+16 11.2 11.2 = .4
Monoxide –––––––––––
rubber bulb aspirator connected to the air outlet of the cock G will enable a
new supply of gas to be drawn into the pipe, the apparatus then being filled
as already described. Another form of aspirator draws the gas from the flue
in a constant stream, thus insuring a fresh supply for each sample.
The analysis made by the Orsat apparatus is volumetric; if the analysis by
weight is required, it can be found from the volumetric analysis as follows:
Multiply the percentages by volume by either the densities or the molecular
weight of each gas, and divide the products by the sum of all the products;
the quotients will be the percentages by weight. For most work sufficient
accuracy is secured by using the even values of the molecular weights.
The even values of the molecular weights of the gases appearing in an
analysis by an Orsat are:
Carbon Dioxide 44
Carbon Monoxide 28
Oxygen 32
Nitrogen 28
Table 33 indicates the method of converting a volumetric flue gas analysis
into an analysis by weight.
TABLE 33
CONVERSION OF A FLUE GAS ANALYSIS BY VOLUME TO ONE BY
WEIGHT
Volume
Analysis by Analysis by
Molecular times
Gas Volume Weight
Weight Molecular
Per Cent Per Cent
Weight
536.8
Carbon CO
12.2 12+(2×16) 536.8 ––––––––––– = 17.7
Dioxide 2 3022.8
Carbon CO .4 12+16 11.2 11.2 = .4
Monoxide –––––––––––
Page 221
3022.8
220.8
Oxygen O 6.9 2×16 220.8 ––––––––––– = 7.3
3022.8
2254.0
Nitrogen N 80.5 2×14 2254.0 ––––––––––– = 74.6
3022.8
Total 100.0 3022.8 100.0
Application of Formulae and Rules —Pocahontas coal is burned in the
furnace, a partial ultimate analysis being:
Per Cent
Carbon 82.1
Hydrogen 4.25
Oxygen 2.6
Sulphur 1.6
Ash 6.0
B. t. u., per pound dry 14500
[Pg 162]
The flue gas analysis shows:
Per Cent
CO 2 10.7
O 9.0
CO 0.0
N (by difference) 80.3
Determine: The flue gas analysis by weight (see Table 33 ), the amount of air
required for perfect combustion, the actual weight of air per pound of fuel,
the weight of flue gas per pound of coal, the heat lost in the chimney gases if
the temperature of these is 500 degrees Fahrenheit, and the ratio of the air
supplied to that theoretically required.
220.8
Oxygen O 6.9 2×16 220.8 ––––––––––– = 7.3
3022.8
2254.0
Nitrogen N 80.5 2×14 2254.0 ––––––––––– = 74.6
3022.8
Total 100.0 3022.8 100.0
Application of Formulae and Rules —Pocahontas coal is burned in the
furnace, a partial ultimate analysis being:
Per Cent
Carbon 82.1
Hydrogen 4.25
Oxygen 2.6
Sulphur 1.6
Ash 6.0
B. t. u., per pound dry 14500
[Pg 162]
The flue gas analysis shows:
Per Cent
CO 2 10.7
O 9.0
CO 0.0
N (by difference) 80.3
Determine: The flue gas analysis by weight (see Table 33 ), the amount of air
required for perfect combustion, the actual weight of air per pound of fuel,
the weight of flue gas per pound of coal, the heat lost in the chimney gases if
the temperature of these is 500 degrees Fahrenheit, and the ratio of the air
supplied to that theoretically required.
Page 222
Solution: The theoretical weight of air required for perfect combustion, per
pound of fuel, from formula ( 11 ) will be,
.821 .026 .016
W = 34.56 ( 3 + ( .0425 - 8 ) + 8 ) = 10.88 pounds.
––––––– ––––––– –––––––
If the amount of carbon which is burned and passes away as flue gas is 80
per cent, which would allow for 2.1 per cent of unburned carbon in terms of
the total weight of dry fuel burned, the weight of dry gas per pound of
carbon burned will be from formula ( 16 ):
11 × 10.7 + 8 × 9.0 + 7(0 + 80.3)
W= ––––––––––––––––––––––––––––––––––––––––––––––––––––– = 23.42 pounds
3 (10.7 + 0)
and the weight of flue gas per pound of coal burned will be .80 × 23.42 =
18.74 pounds.
The heat lost in the flue gases per pound of coal burned will be from formula
( 15 ) and the value 18.74 just determined.
Loss = .24 × 18.74 × (500 - 60) = 1979 B. t. u.
The percentage of heat lost in the flue gases will be 1979 ÷ 14500 = 13.6 per
cent.
The ratio of air supplied per pound of coal to that theoretically required will
be 18.74 ÷ 10.88 = 1.72 per cent.
The ratio of air supplied per pound of combustible to that required will be
from formula ( 14 ):
.803
––––––––––––––––––––––––––––––––––––––– = 1.73
.803 - 3.782(.09 - ½ × 0)
pound of fuel, from formula ( 11 ) will be,
.821 .026 .016
W = 34.56 ( 3 + ( .0425 - 8 ) + 8 ) = 10.88 pounds.
––––––– ––––––– –––––––
If the amount of carbon which is burned and passes away as flue gas is 80
per cent, which would allow for 2.1 per cent of unburned carbon in terms of
the total weight of dry fuel burned, the weight of dry gas per pound of
carbon burned will be from formula ( 16 ):
11 × 10.7 + 8 × 9.0 + 7(0 + 80.3)
W= ––––––––––––––––––––––––––––––––––––––––––––––––––––– = 23.42 pounds
3 (10.7 + 0)
and the weight of flue gas per pound of coal burned will be .80 × 23.42 =
18.74 pounds.
The heat lost in the flue gases per pound of coal burned will be from formula
( 15 ) and the value 18.74 just determined.
Loss = .24 × 18.74 × (500 - 60) = 1979 B. t. u.
The percentage of heat lost in the flue gases will be 1979 ÷ 14500 = 13.6 per
cent.
The ratio of air supplied per pound of coal to that theoretically required will
be 18.74 ÷ 10.88 = 1.72 per cent.
The ratio of air supplied per pound of combustible to that required will be
from formula ( 14 ):
.803
––––––––––––––––––––––––––––––––––––––– = 1.73
.803 - 3.782(.09 - ½ × 0)
Page 223
The ratio based on combustible will be greater than the ratio based on fuel if
there is unconsumed carbon in the ash.
Unreliability of CO 2 Readings Taken Alone —It is generally assumed that
high CO 2 readings are indicative of good combustion and hence of high
efficiency. This is true only in the sense that such high readings do indicate
the small amount of excess air that usually accompanies good combustion,
and for this reason high CO 2 readings alone are not considered entirely
reliable. Wherever an automatic CO 2 recorder is used, it should be checked
from time to time and the analysis carried further with a view to ascertaining
whether there is CO present. As the percentage of CO 2 in these gases
increases, there is a tendency toward the presence of CO, which, of course,
cannot be shown by a CO 2 recorder, and which is often difficult to detect
with an Orsat apparatus. The greatest care should be taken in preparing the
cuprous chloride solution in making analyses and it must be known to be
fresh and capable of absorbing CO. [Pg 163] In one instance that came to our
attention, in using an Orsat apparatus where the cuprous chloride solution
was believed to be fresh, no CO was indicated in the flue gases but on
passing the same sample into a Hempel apparatus, a considerable percentage
was found. It is not safe, therefore, to assume without question from a high
CO 2 reading that the combustion is correspondingly good, and the question
of excess air alone should be distinguished from that of good combustion.
The effect of a small quantity of CO, say one per cent, present in the flue
gases will have a negligible influence on the quantity of excess air, but the
presence of such an amount would mean a loss due to the incomplete
combustion of the carbon in the fuel of possibly 4.5 per cent of the total heat
in the fuel burned. When this is considered, the importance of a complete
flue gas analysis is apparent.
Table 34 gives the densities of various gases together with other data that
will be of service in gas analysis work.
TABLE 34
DENSITY OF GASES AT 32 DEGREES FAHRENHEIT AND
ATMOSPHERIC PRESSURE
ADAPTED FROM SMITHSONIAN TABLES
there is unconsumed carbon in the ash.
Unreliability of CO 2 Readings Taken Alone —It is generally assumed that
high CO 2 readings are indicative of good combustion and hence of high
efficiency. This is true only in the sense that such high readings do indicate
the small amount of excess air that usually accompanies good combustion,
and for this reason high CO 2 readings alone are not considered entirely
reliable. Wherever an automatic CO 2 recorder is used, it should be checked
from time to time and the analysis carried further with a view to ascertaining
whether there is CO present. As the percentage of CO 2 in these gases
increases, there is a tendency toward the presence of CO, which, of course,
cannot be shown by a CO 2 recorder, and which is often difficult to detect
with an Orsat apparatus. The greatest care should be taken in preparing the
cuprous chloride solution in making analyses and it must be known to be
fresh and capable of absorbing CO. [Pg 163] In one instance that came to our
attention, in using an Orsat apparatus where the cuprous chloride solution
was believed to be fresh, no CO was indicated in the flue gases but on
passing the same sample into a Hempel apparatus, a considerable percentage
was found. It is not safe, therefore, to assume without question from a high
CO 2 reading that the combustion is correspondingly good, and the question
of excess air alone should be distinguished from that of good combustion.
The effect of a small quantity of CO, say one per cent, present in the flue
gases will have a negligible influence on the quantity of excess air, but the
presence of such an amount would mean a loss due to the incomplete
combustion of the carbon in the fuel of possibly 4.5 per cent of the total heat
in the fuel burned. When this is considered, the importance of a complete
flue gas analysis is apparent.
Table 34 gives the densities of various gases together with other data that
will be of service in gas analysis work.
TABLE 34
DENSITY OF GASES AT 32 DEGREES FAHRENHEIT AND
ATMOSPHERIC PRESSURE
ADAPTED FROM SMITHSONIAN TABLES
Page 224
Weight Volume
of of Relative Density,
Specific Hydrogen = 1
Chemical One One
Gas Gravity
Symbol Cubic Pound
Air=1
Foot Cubic
Exact Approximate
Pounds Feet
Oxygen O 1.053 .08922 11.208 15.87 16
Nitrogen N 0.9673 .07829 12.773 13.92 14
Hydrogen H 0.0696 .005621 177.90 1.00 1
Carbon
CO 2 1.5291 .12269 8.151 21.83 22
Dioxide
Carbon
CO 0.9672 .07807 12.809 13.89 14
Monoxide
Methane CH 4 0.5576 .04470 22.371 7.95 8
Ethane C 2 H 6 1.075 .08379 11.935 14.91 15
Acetylene C 2 H 2 0.920 .07254 13.785 12.91 13
Sulphur
SO 2 2.2639 .17862 5.598 31.96 32
Dioxide
…
Air … 1.0000 .08071 12.390 …
[Pg 164]
of of Relative Density,
Specific Hydrogen = 1
Chemical One One
Gas Gravity
Symbol Cubic Pound
Air=1
Foot Cubic
Exact Approximate
Pounds Feet
Oxygen O 1.053 .08922 11.208 15.87 16
Nitrogen N 0.9673 .07829 12.773 13.92 14
Hydrogen H 0.0696 .005621 177.90 1.00 1
Carbon
CO 2 1.5291 .12269 8.151 21.83 22
Dioxide
Carbon
CO 0.9672 .07807 12.809 13.89 14
Monoxide
Methane CH 4 0.5576 .04470 22.371 7.95 8
Ethane C 2 H 6 1.075 .08379 11.935 14.91 15
Acetylene C 2 H 2 0.920 .07254 13.785 12.91 13
Sulphur
SO 2 2.2639 .17862 5.598 31.96 32
Dioxide
…
Air … 1.0000 .08071 12.390 …
[Pg 164]
Page 225
1942 Horse-power Installation of Babcock & Wilcox Boilers and
Superheaters in the Singer Building, New York City
FOOTNOTES
[28] See Table 31 , page 151 .
[29] This formula is equivalent to ( 10 ) given in chapter on combustion . 34.56 =
theoretical air required for combustion of one pound of H (see Table 31 ).
[30] For degree of accuracy of this formula, see Transactions, A. S. M. E., Volume
XXI, 1900, page 94.
Superheaters in the Singer Building, New York City
FOOTNOTES
[28] See Table 31 , page 151 .
[29] This formula is equivalent to ( 10 ) given in chapter on combustion . 34.56 =
theoretical air required for combustion of one pound of H (see Table 31 ).
[30] For degree of accuracy of this formula, see Transactions, A. S. M. E., Volume
XXI, 1900, page 94.
Page 226
[31] For loss per pound of coal multiply by per cent of carbon in coal by ultimate
analysis.
[32] For loss per pound of coal multiply by per cent of carbon in coal by ultimate
analysis.
analysis.
[32] For loss per pound of coal multiply by per cent of carbon in coal by ultimate
analysis.
Page 227
[Pg 165]
Page 228
CLASSIFICATION OF FUELS
(WITH PARTICULAR REFERENCE TO COAL)
Fuels for steam boilers may be classified as solid, liquid or gaseous. Of the
solid fuels, anthracite and bituminous coals are the most common, but in this
class must also be included lignite, peat, wood, bagasse and the refuse from
certain industrial processes such as sawdust, shavings, tan bark and the like.
Straw, corn and coffee husks are utilized in isolated cases.
The class of liquid fuels is represented chiefly by petroleum, though coal tar
and water-gas tar are used to a limited extent.
Gaseous fuels are limited to natural gas, blast furnace gas and coke oven gas,
the first being a natural product and the two latter by-products from
industrial processes. Though waste gases from certain processes may be
considered as gaseous fuels, inasmuch as the question of combustion does
not enter, the methods of utilizing them differ from that for combustible
gaseous fuel, and the question will be dealt with separately.
Since coal is by far the most generally used of all fuels, this chapter will be
devoted entirely to the formation, composition and distribution of the
various grades, from anthracite to peat. The other fuels will be discussed in
succeeding chapters and their combustion dealt with in connection with their
composition.
TABLE 35 Formation of Coal
—All coals are of
APPROXIMATE CHEMICAL CHANGES vegetable origin and
FROM WOOD are the remains of
FIBER TO ANTHRACITE COAL prehistoric forests.
Substance Carbon Hydrogen Oxygen Destructive
Wood Fiber 52.65 5.25 42.10 distillation due to
Peat 59.57 5.96 34.47 great pressures and
temperatures, has
Lignite 66.04 5.27 28.69
(WITH PARTICULAR REFERENCE TO COAL)
Fuels for steam boilers may be classified as solid, liquid or gaseous. Of the
solid fuels, anthracite and bituminous coals are the most common, but in this
class must also be included lignite, peat, wood, bagasse and the refuse from
certain industrial processes such as sawdust, shavings, tan bark and the like.
Straw, corn and coffee husks are utilized in isolated cases.
The class of liquid fuels is represented chiefly by petroleum, though coal tar
and water-gas tar are used to a limited extent.
Gaseous fuels are limited to natural gas, blast furnace gas and coke oven gas,
the first being a natural product and the two latter by-products from
industrial processes. Though waste gases from certain processes may be
considered as gaseous fuels, inasmuch as the question of combustion does
not enter, the methods of utilizing them differ from that for combustible
gaseous fuel, and the question will be dealt with separately.
Since coal is by far the most generally used of all fuels, this chapter will be
devoted entirely to the formation, composition and distribution of the
various grades, from anthracite to peat. The other fuels will be discussed in
succeeding chapters and their combustion dealt with in connection with their
composition.
TABLE 35 Formation of Coal
—All coals are of
APPROXIMATE CHEMICAL CHANGES vegetable origin and
FROM WOOD are the remains of
FIBER TO ANTHRACITE COAL prehistoric forests.
Substance Carbon Hydrogen Oxygen Destructive
Wood Fiber 52.65 5.25 42.10 distillation due to
Peat 59.57 5.96 34.47 great pressures and
temperatures, has
Lignite 66.04 5.27 28.69
Page 229
Earthy Brown Coal 73.18 5.68 21.14 resolved the organic
Bituminous Coal 75.06 5.84 19.10 matter into its
Semi-bituminous Coal 89.29 5.05 5.66 invariable ultimate
Anthracite Coal 91.58 3.96 4.46 constituents, carbon,
hydrogen, oxygen
and other substances, in varying proportions. The factors of time, depth of
beds, disturbance of beds and the intrusion of mineral matter resulting from
such disturbances have produced the variation in the degree of evolution
from vegetable fiber to hard coal. This variation is shown chiefly in the
content of carbon, and Table 35 shows the steps of such variation.
Composition of Coal—The uncombined carbon in coal is known as fixed
carbon. Some of the carbon constituent is combined with hydrogen and this,
together with other gaseous substances driven off by the application of heat,
form that portion of the coal known as volatile matter. The fixed carbon and
the volatile matter constitute the combustible. The oxygen and nitrogen
contained in the volatile matter are not combustible, but custom has applied
this term to that portion of the coal which is dry and free from ash, thus
including the oxygen and nitrogen.
The other important substances entering into the composition of coal are
moisture and the refractory earths which form the ash. The ash varies in
different coals from 3 to 30 per cent and the moisture from 0.75 to 45 per
cent of the total weight of the [Pg 166] coal, depending upon the grade and the
locality in which it is mined. A large percentage of ash is undesirable as it
not only reduces the calorific value of the fuel, but chokes up the air
passages in the furnace and through the fuel bed, thus preventing the rapid
combustion necessary to high efficiency. If the coal contains an excessive
quantity of sulphur, trouble will result from its harmful action on the metal
of the boiler where moisture is present, and because it unites with the ash to
form a fusible slag or clinker which will choke up the grate bars and form a
solid mass in which large quantities of unconsumed carbon may be
imbedded.
Moisture in coal may be more detrimental than ash in reducing the
temperature of a furnace, as it is non-combustible, absorbs heat both in being
evaporated and superheated to the temperature of the furnace gases. In some
instances, however, a certain amount of moisture in a bituminous coal
Bituminous Coal 75.06 5.84 19.10 matter into its
Semi-bituminous Coal 89.29 5.05 5.66 invariable ultimate
Anthracite Coal 91.58 3.96 4.46 constituents, carbon,
hydrogen, oxygen
and other substances, in varying proportions. The factors of time, depth of
beds, disturbance of beds and the intrusion of mineral matter resulting from
such disturbances have produced the variation in the degree of evolution
from vegetable fiber to hard coal. This variation is shown chiefly in the
content of carbon, and Table 35 shows the steps of such variation.
Composition of Coal—The uncombined carbon in coal is known as fixed
carbon. Some of the carbon constituent is combined with hydrogen and this,
together with other gaseous substances driven off by the application of heat,
form that portion of the coal known as volatile matter. The fixed carbon and
the volatile matter constitute the combustible. The oxygen and nitrogen
contained in the volatile matter are not combustible, but custom has applied
this term to that portion of the coal which is dry and free from ash, thus
including the oxygen and nitrogen.
The other important substances entering into the composition of coal are
moisture and the refractory earths which form the ash. The ash varies in
different coals from 3 to 30 per cent and the moisture from 0.75 to 45 per
cent of the total weight of the [Pg 166] coal, depending upon the grade and the
locality in which it is mined. A large percentage of ash is undesirable as it
not only reduces the calorific value of the fuel, but chokes up the air
passages in the furnace and through the fuel bed, thus preventing the rapid
combustion necessary to high efficiency. If the coal contains an excessive
quantity of sulphur, trouble will result from its harmful action on the metal
of the boiler where moisture is present, and because it unites with the ash to
form a fusible slag or clinker which will choke up the grate bars and form a
solid mass in which large quantities of unconsumed carbon may be
imbedded.
Moisture in coal may be more detrimental than ash in reducing the
temperature of a furnace, as it is non-combustible, absorbs heat both in being
evaporated and superheated to the temperature of the furnace gases. In some
instances, however, a certain amount of moisture in a bituminous coal
Page 230
produces a mechanical action that assists in the combustion and makes it
possible to develop higher capacities than with dry coal.
Classification of Coal—Custom has classified coals in accordance with the
varying content of carbon and volatile matter in the combustible. Table 36
gives the approximate percentages of these constituents for the general
classes of coals with the corresponding heat values per pound of
combustible.
TABLE 36
APPROXIMATE COMPOSITION AND CALORIFIC VALUE
OF GENERAL GRADES OF COAL ON BASIS OF
COMBUSTIBLE
Per Cent of Combustible B. t. u.
Kind of Coal Per Pound of
Fixed Carbon Volatile Matter Combustible
Anthracite 97.0 to 92.5 3.0 to 7.5 14600 to 14800
Semi-anthracite 92.5 to 87.5 7.5 to 12.5 14700 to 15500
Semi-bituminous 87.5 to 75.0 12.5 to 25.0 15500 to 16000
Bituminous—Eastern 75.0 to 60.0 25.0 to 40.0 14800 to 15300
Bituminous—Western 65.0 to 50.0 35.0 to 50.0 13500 to 14800
Lignite Under 50 Over 50 11000 to 13500
Anthracite—The name anthracite, or hard coal, is applied to those dry coals
containing from 3 to 7 per cent volatile matter and which do not swell when
burned. True anthracite is hard, compact, lustrous and sometimes iridescent,
and is characterized by few joints and clefts. Its specific gravity varies from
1.4 to 1.8. In burning, it kindles slowly and with difficulty, is hard to keep
alight, and burns with a short, almost colorless flame, without smoke.
Semi-anthracite coal has less density, hardness and luster than true
anthracite, and can be distinguished from it by the fact that when newly
fractured it will soot the hands. Its specific gravity is ordinarily about 1.4. It
kindles quite readily and burns more freely than the true anthracites.
possible to develop higher capacities than with dry coal.
Classification of Coal—Custom has classified coals in accordance with the
varying content of carbon and volatile matter in the combustible. Table 36
gives the approximate percentages of these constituents for the general
classes of coals with the corresponding heat values per pound of
combustible.
TABLE 36
APPROXIMATE COMPOSITION AND CALORIFIC VALUE
OF GENERAL GRADES OF COAL ON BASIS OF
COMBUSTIBLE
Per Cent of Combustible B. t. u.
Kind of Coal Per Pound of
Fixed Carbon Volatile Matter Combustible
Anthracite 97.0 to 92.5 3.0 to 7.5 14600 to 14800
Semi-anthracite 92.5 to 87.5 7.5 to 12.5 14700 to 15500
Semi-bituminous 87.5 to 75.0 12.5 to 25.0 15500 to 16000
Bituminous—Eastern 75.0 to 60.0 25.0 to 40.0 14800 to 15300
Bituminous—Western 65.0 to 50.0 35.0 to 50.0 13500 to 14800
Lignite Under 50 Over 50 11000 to 13500
Anthracite—The name anthracite, or hard coal, is applied to those dry coals
containing from 3 to 7 per cent volatile matter and which do not swell when
burned. True anthracite is hard, compact, lustrous and sometimes iridescent,
and is characterized by few joints and clefts. Its specific gravity varies from
1.4 to 1.8. In burning, it kindles slowly and with difficulty, is hard to keep
alight, and burns with a short, almost colorless flame, without smoke.
Semi-anthracite coal has less density, hardness and luster than true
anthracite, and can be distinguished from it by the fact that when newly
fractured it will soot the hands. Its specific gravity is ordinarily about 1.4. It
kindles quite readily and burns more freely than the true anthracites.
Page 231
Semi-bituminous coal is softer than anthracite, contains more volatile
hydrocarbons, kindles more easily and burns more rapidly. It is ordinarily
free burning, has a high calorific value and is of the highest order for steam
generating purposes.
[Pg 167]
Bituminous coals are still softer than those described and contain still more
volatile hydrocarbons. The difference between the semi-bituminous and the
bituminous coals is an important one, economically. The former have an
average heating value per pound of combustible about 6 per cent higher than
the latter, and they burn with much less smoke in ordinary furnaces. The
distinctive characteristic of the bituminous coals is the emission of yellow
flame and smoke when burning. In color they range from pitch black to dark
brown, having a resinous luster in the most compact specimens, and a silky
luster in such specimens as show traces of vegetable fiber. The specific
gravity is ordinarily about 1.3.
Bituminous coals are either of the caking or non-caking class. The former,
when heated, fuse and swell in size; the latter burn freely, do not fuse, and
are commonly known as free burning coals. Caking coals are rich in volatile
hydrocarbons and are valuable in gas manufacture.
Bituminous coals absorb moisture from the atmosphere. The surface
moisture can be removed by ordinary drying, but a portion of the water can
be removed only by heating the coal to a temperature of about 250 degrees
Fahrenheit.
Cannel coal is a variety of bituminous coal, rich in hydrogen and
hydrocarbons, and is exceedingly valuable as a gas coal. It has a dull
resinous luster and burns with a bright flame without fusing. Cannel coal is
seldom used for steam coal, though it is sometimes mixed with semi-
bituminous coal where an increased economy at high rates of combustion is
desired. The composition of cannel coal is approximately as follows: fixed
carbon, 26 to 55 per cent; volatile matter, 42 to 64 per cent; earthy matter, 2
to 14 per cent. Its specific gravity is approximately 1.24.
hydrocarbons, kindles more easily and burns more rapidly. It is ordinarily
free burning, has a high calorific value and is of the highest order for steam
generating purposes.
[Pg 167]
Bituminous coals are still softer than those described and contain still more
volatile hydrocarbons. The difference between the semi-bituminous and the
bituminous coals is an important one, economically. The former have an
average heating value per pound of combustible about 6 per cent higher than
the latter, and they burn with much less smoke in ordinary furnaces. The
distinctive characteristic of the bituminous coals is the emission of yellow
flame and smoke when burning. In color they range from pitch black to dark
brown, having a resinous luster in the most compact specimens, and a silky
luster in such specimens as show traces of vegetable fiber. The specific
gravity is ordinarily about 1.3.
Bituminous coals are either of the caking or non-caking class. The former,
when heated, fuse and swell in size; the latter burn freely, do not fuse, and
are commonly known as free burning coals. Caking coals are rich in volatile
hydrocarbons and are valuable in gas manufacture.
Bituminous coals absorb moisture from the atmosphere. The surface
moisture can be removed by ordinary drying, but a portion of the water can
be removed only by heating the coal to a temperature of about 250 degrees
Fahrenheit.
Cannel coal is a variety of bituminous coal, rich in hydrogen and
hydrocarbons, and is exceedingly valuable as a gas coal. It has a dull
resinous luster and burns with a bright flame without fusing. Cannel coal is
seldom used for steam coal, though it is sometimes mixed with semi-
bituminous coal where an increased economy at high rates of combustion is
desired. The composition of cannel coal is approximately as follows: fixed
carbon, 26 to 55 per cent; volatile matter, 42 to 64 per cent; earthy matter, 2
to 14 per cent. Its specific gravity is approximately 1.24.
Page 232
Lignite is organic matter in the earlier stages of its conversion into coal, and
includes all varieties which are intermediate between peat and coal of the
older formation. Its specific gravity is low, being 1.2 to 1.23, and when
freshly mined it may contain as high as 50 per cent of moisture. Its
appearance varies from a light brown, showing a distinctly woody structure,
in the poorer varieties, to a black, with a pitchy luster resembling hard coal,
in the best varieties. It is non-caking and burns with a bright but slightly
smoky flame with moderate heat. It is easily broken, will not stand much
handling in transportation, and if exposed to the weather will rapidly
disintegrate, which will increase the difficulty of burning it.
Its composition varies over wide limits. The ash may run as low as one per
cent and as high as 50 per cent. Its high content of moisture and the large
quantity of air necessary for its combustion cause large stack losses. It is
distinctly a low-grade fuel and is used almost entirely in the districts where
mined, due to its cheapness.
Peat is organic matter in the first stages of its conversion into coal and is
found in bogs and similar places. Its moisture content when cut is extremely
high, averaging 75 or 80 per cent. It is unsuitable for fuel until dried and
even then will contain as much as 30 per cent moisture. Its ash content when
dry varies from 3 to 12 per cent. In this country, though large deposits of
peat have been found, it has not as yet been found practicable to utilize it for
steam generating purposes in competition with coal. In some European
countries, however, the peat industry is common.
Distribution—The anthracite coals are, with some unimportant exceptions,
confined to five small fields in Eastern Pennsylvania, as shown in the
following list. These fields are given in the order of their hardness.
Lehigh or Eastern Middle Field
Wyoming or Northern Field
[Pg 168]
Green Mountain District Continued
Black Creek District Pittston District
Hazelton District Wilkesbarre District
Beaver Meadow District Plymouth District
Panther Creek District[33] Schuylkill or Southern Field
includes all varieties which are intermediate between peat and coal of the
older formation. Its specific gravity is low, being 1.2 to 1.23, and when
freshly mined it may contain as high as 50 per cent of moisture. Its
appearance varies from a light brown, showing a distinctly woody structure,
in the poorer varieties, to a black, with a pitchy luster resembling hard coal,
in the best varieties. It is non-caking and burns with a bright but slightly
smoky flame with moderate heat. It is easily broken, will not stand much
handling in transportation, and if exposed to the weather will rapidly
disintegrate, which will increase the difficulty of burning it.
Its composition varies over wide limits. The ash may run as low as one per
cent and as high as 50 per cent. Its high content of moisture and the large
quantity of air necessary for its combustion cause large stack losses. It is
distinctly a low-grade fuel and is used almost entirely in the districts where
mined, due to its cheapness.
Peat is organic matter in the first stages of its conversion into coal and is
found in bogs and similar places. Its moisture content when cut is extremely
high, averaging 75 or 80 per cent. It is unsuitable for fuel until dried and
even then will contain as much as 30 per cent moisture. Its ash content when
dry varies from 3 to 12 per cent. In this country, though large deposits of
peat have been found, it has not as yet been found practicable to utilize it for
steam generating purposes in competition with coal. In some European
countries, however, the peat industry is common.
Distribution—The anthracite coals are, with some unimportant exceptions,
confined to five small fields in Eastern Pennsylvania, as shown in the
following list. These fields are given in the order of their hardness.
Lehigh or Eastern Middle Field
Wyoming or Northern Field
[Pg 168]
Green Mountain District Continued
Black Creek District Pittston District
Hazelton District Wilkesbarre District
Beaver Meadow District Plymouth District
Panther Creek District[33] Schuylkill or Southern Field
Page 233
Mahanoy or Western Field[34] East Schuylkill District
East Mahanoy District West Schuylkill District
West Mahanoy District Louberry District
Lykens Valley or Southwestern
Wyoming or Northern Field
Field
Carbondale District Lykens Valley District
Scranton District Shamokin District[35]
Anthracite is also found in Pulaski and Wythe Counties, Virginia; along the
border of Little Walker Mountain, and in Gunnison County, Colorado. The
areas in Virginia are limited, however, while in Colorado the quality varies
greatly in neighboring beds and even in the same bed. An anthracite bed in
New Mexico was described in 1870 by Dr. R. W. Raymond, formerly United
States Mining Commissioner.
Semi-anthracite coals are found in a few small areas in the western part of
the anthracite field. The largest of these beds is the Bernice in Sullivan
County, Pennsylvania. Mr. William Kent, in his “Steam Boiler Economy”,
describes this as follows: “The Bernice semi-anthracite coal basin lies
between Beech Creek on the north and Loyalsock Creek on the south. It is
six miles long, east and west, and hardly a third of a mile across. An 8-foot
vein of coal lies in a bed of 12 feet of coal and slate. The coal of this bed is
the dividing line between anthracite and semi-anthracite, and is similar to the
coal of the Lykens Valley District. Mine analyses give a range as follows:
moisture, 0.65 to 1.97; volatile matter, 3.56 to 9.40; fixed carbon, 82.52 to
89.39; ash, 3.27 to 9.34; sulphur, 0.24 to 1.04.”
Semi-bituminous coals are found on the eastern edge of the great
Appalachian Field. Starting with Tioga and Bradford Counties of northern
Pennsylvania, the bed runs southwest through Lycoming, Clearfield, Centre,
Huntingdon, Cambria, Somerset and Fulton Counties, Pennsylvania;
Allegheny County, Maryland; Buchannan, Dickinson, Lee, Russell, Scott,
Tazewell and Wise Counties, Virginia; Mercer, McDowell, Fayette, Raleigh
and Mineral Counties, West Virginia; and ending in northeastern Tennessee,
where a small amount of semi-bituminous is mined.
East Mahanoy District West Schuylkill District
West Mahanoy District Louberry District
Lykens Valley or Southwestern
Wyoming or Northern Field
Field
Carbondale District Lykens Valley District
Scranton District Shamokin District[35]
Anthracite is also found in Pulaski and Wythe Counties, Virginia; along the
border of Little Walker Mountain, and in Gunnison County, Colorado. The
areas in Virginia are limited, however, while in Colorado the quality varies
greatly in neighboring beds and even in the same bed. An anthracite bed in
New Mexico was described in 1870 by Dr. R. W. Raymond, formerly United
States Mining Commissioner.
Semi-anthracite coals are found in a few small areas in the western part of
the anthracite field. The largest of these beds is the Bernice in Sullivan
County, Pennsylvania. Mr. William Kent, in his “Steam Boiler Economy”,
describes this as follows: “The Bernice semi-anthracite coal basin lies
between Beech Creek on the north and Loyalsock Creek on the south. It is
six miles long, east and west, and hardly a third of a mile across. An 8-foot
vein of coal lies in a bed of 12 feet of coal and slate. The coal of this bed is
the dividing line between anthracite and semi-anthracite, and is similar to the
coal of the Lykens Valley District. Mine analyses give a range as follows:
moisture, 0.65 to 1.97; volatile matter, 3.56 to 9.40; fixed carbon, 82.52 to
89.39; ash, 3.27 to 9.34; sulphur, 0.24 to 1.04.”
Semi-bituminous coals are found on the eastern edge of the great
Appalachian Field. Starting with Tioga and Bradford Counties of northern
Pennsylvania, the bed runs southwest through Lycoming, Clearfield, Centre,
Huntingdon, Cambria, Somerset and Fulton Counties, Pennsylvania;
Allegheny County, Maryland; Buchannan, Dickinson, Lee, Russell, Scott,
Tazewell and Wise Counties, Virginia; Mercer, McDowell, Fayette, Raleigh
and Mineral Counties, West Virginia; and ending in northeastern Tennessee,
where a small amount of semi-bituminous is mined.
Page 234
The largest of the bituminous fields is the Appalachian. Beginning near the
northern boundary of Pennsylvania, in the western portion of the State, it
extends southwestward through West Virginia, touching Maryland and
Virginia on their western borders, passing through southeastern Ohio,
eastern Kentucky and central Tennessee, and ending in western Alabama,
900 miles from its northern extremity.
The next bituminous coal producing region to the west is the Northern Field,
in north central Michigan. Still further to the west, and second in importance
to the [Pg 169] Appalachian Field, is the Eastern Interior Field. This covers,
with the exception of the upper northern portion, nearly the entire State of
Illinois, southwest Indiana and the western portion of Kentucky.
The Western Field extends through central and southern Iowa, western
Missouri, southwestern Kansas, eastern Oklahoma and the west central
portion of Arkansas. The Southwestern Field is confined entirely to the north
central portion of Texas, in which State there are also two small isolated
fields along the Rio Grande River.
The remaining bituminous fields are scattered through what may be termed
the Rocky Mountain Region, extending from Montana to New Orleans. A
partial list of these fields and their location follows:
Judith Basin Central Montana
Bull Mountain Field Central Montana
Yellowstone Region Southwestern Montana
Big Horn Basin Region Southern Montana
Big Horn Basin Region Northern Wyoming
Black Hills Region Northeastern Wyoming
Hanna Field Southern Wyoming
Green River Region Southwestern Wyoming
Yampa Field Northwestern Colorado
North Park Field Northern Colorado
Denver Region North Central Colorado
Uinta Region Western Colorado
Uinta Region Eastern Utah
northern boundary of Pennsylvania, in the western portion of the State, it
extends southwestward through West Virginia, touching Maryland and
Virginia on their western borders, passing through southeastern Ohio,
eastern Kentucky and central Tennessee, and ending in western Alabama,
900 miles from its northern extremity.
The next bituminous coal producing region to the west is the Northern Field,
in north central Michigan. Still further to the west, and second in importance
to the [Pg 169] Appalachian Field, is the Eastern Interior Field. This covers,
with the exception of the upper northern portion, nearly the entire State of
Illinois, southwest Indiana and the western portion of Kentucky.
The Western Field extends through central and southern Iowa, western
Missouri, southwestern Kansas, eastern Oklahoma and the west central
portion of Arkansas. The Southwestern Field is confined entirely to the north
central portion of Texas, in which State there are also two small isolated
fields along the Rio Grande River.
The remaining bituminous fields are scattered through what may be termed
the Rocky Mountain Region, extending from Montana to New Orleans. A
partial list of these fields and their location follows:
Judith Basin Central Montana
Bull Mountain Field Central Montana
Yellowstone Region Southwestern Montana
Big Horn Basin Region Southern Montana
Big Horn Basin Region Northern Wyoming
Black Hills Region Northeastern Wyoming
Hanna Field Southern Wyoming
Green River Region Southwestern Wyoming
Yampa Field Northwestern Colorado
North Park Field Northern Colorado
Denver Region North Central Colorado
Uinta Region Western Colorado
Uinta Region Eastern Utah
Page 235
Southwestern Region Southwestern Utah
Raton Mountain Region Southern Colorado
Raton Mountain Region Northern New Mexico
San Juan River Region Northwestern New Mexico
Capitan Field Southern New Mexico
Along the Pacific Coast a few small fields are scattered in western
California, southwestern Oregon, western and northwestern Washington.
Most of the coals in the above fields are on the border line between
bituminous and lignite. They are really a low grade of bituminous coal and
are known as sub-bituminous or black lignites.
Lignites—These resemble the brown coals of Europe and are found in the
western states, Wyoming, New Mexico, Arizona, Utah, Montana, North
Dakota, Nevada, California, Oregon and Washington. Many of the fields
given as those containing bituminous coals in the western states also contain
true lignite. Lignite is also found in the eastern part of Texas and in
Oklahoma.
Alaska Coals—Coal has been found in Alaska and undoubtedly is of great
value, though the extent and character of the fields have probably been
exaggerated. Great quantities of lignite are known to exist, and in quality the
coal ranges in character from lignite to anthracite. There are at present,
however, only two fields of high-grade coals known, these being the Bering
River Field, near Controllers Bay, and the Matanuska Field, at the head of
Cooks Inlet. Both of these fields are known to contain both anthracite and
high-grade bituminous coals, though as yet they cannot be said to have been
opened up.
Weathering of Coal—The storage of coal has become within the last few
years to a certain extent a necessity due to market conditions, danger of labor
difficulties at the mines and in the railroads, and the crowding of
transportation facilities. [Pg 170] The first cause is probably the most
important, and this is particularly true of anthracite coals where a sliding
scale of prices is used according to the season of the year. While market
conditions serve as one of the principal reasons for coal storage, most power
Raton Mountain Region Southern Colorado
Raton Mountain Region Northern New Mexico
San Juan River Region Northwestern New Mexico
Capitan Field Southern New Mexico
Along the Pacific Coast a few small fields are scattered in western
California, southwestern Oregon, western and northwestern Washington.
Most of the coals in the above fields are on the border line between
bituminous and lignite. They are really a low grade of bituminous coal and
are known as sub-bituminous or black lignites.
Lignites—These resemble the brown coals of Europe and are found in the
western states, Wyoming, New Mexico, Arizona, Utah, Montana, North
Dakota, Nevada, California, Oregon and Washington. Many of the fields
given as those containing bituminous coals in the western states also contain
true lignite. Lignite is also found in the eastern part of Texas and in
Oklahoma.
Alaska Coals—Coal has been found in Alaska and undoubtedly is of great
value, though the extent and character of the fields have probably been
exaggerated. Great quantities of lignite are known to exist, and in quality the
coal ranges in character from lignite to anthracite. There are at present,
however, only two fields of high-grade coals known, these being the Bering
River Field, near Controllers Bay, and the Matanuska Field, at the head of
Cooks Inlet. Both of these fields are known to contain both anthracite and
high-grade bituminous coals, though as yet they cannot be said to have been
opened up.
Weathering of Coal—The storage of coal has become within the last few
years to a certain extent a necessity due to market conditions, danger of labor
difficulties at the mines and in the railroads, and the crowding of
transportation facilities. [Pg 170] The first cause is probably the most
important, and this is particularly true of anthracite coals where a sliding
scale of prices is used according to the season of the year. While market
conditions serve as one of the principal reasons for coal storage, most power
Page 236
plants and manufacturing plants feel compelled to protect their coal supply
from the danger of strikes, car shortages and the like, and it is customary for
large power plants, railroads and coal companies themselves, to store
bituminous coal. Naval coaling stations are also an example of what is done
along these lines.
Anthracite is the nearest approach to the ideal coal for storing. It is not
subject to spontaneous ignition, and for this reason is unlimited in the
amount that may be stored in one pile. With bituminous coals, however, the
case is different. Most bituminous coals will ignite if placed in large enough
piles and all suffer more or less from disintegration. Coal producers only
store such coals as are least liable to ignite, and which will stand rehandling
for shipment.
The changes which take place in stored coal are of two kinds: 1st, the
oxidization of the inorganic matter such as pyrites; and 2nd, the direct
oxidization of the organic matter of the actual coal.
The first change will result in an increased volume of the coal, and
sometimes in an increased weight, and a marked disintegration. The changes
due to direct oxidization of the coal substances usually cannot be detected by
the eye, but as they involve the oxidization of the carbon and available
hydrogen and the absorption of the oxygen by unsaturated hydrocarbons,
they are the chief cause of the weathering losses in heat value. Numerous
experiments have led to the conclusion that this is also the cause for
spontaneous combustion.
Experiments to show loss in calorific heat values due to weathering indicate
that such loss may be as high as 10 per cent when the coal is stored in the air,
and 8.75 per cent when stored under water. It would appear that the higher
the volatile content of the coal, the greater will be the loss in calorific value
and the more subject to spontaneous ignition.
Some experiments made by Messrs. S. W. Parr and W. F. Wheeler, published
in 1909 by the Experiment Station of the University of Illinois, indicate that
coals of the nature found in Illinois and neighboring states are not affected
seriously during storage from the standpoint of weight and heating value, the
latter loss averaging about 3½ per cent for the first year of storage. They
from the danger of strikes, car shortages and the like, and it is customary for
large power plants, railroads and coal companies themselves, to store
bituminous coal. Naval coaling stations are also an example of what is done
along these lines.
Anthracite is the nearest approach to the ideal coal for storing. It is not
subject to spontaneous ignition, and for this reason is unlimited in the
amount that may be stored in one pile. With bituminous coals, however, the
case is different. Most bituminous coals will ignite if placed in large enough
piles and all suffer more or less from disintegration. Coal producers only
store such coals as are least liable to ignite, and which will stand rehandling
for shipment.
The changes which take place in stored coal are of two kinds: 1st, the
oxidization of the inorganic matter such as pyrites; and 2nd, the direct
oxidization of the organic matter of the actual coal.
The first change will result in an increased volume of the coal, and
sometimes in an increased weight, and a marked disintegration. The changes
due to direct oxidization of the coal substances usually cannot be detected by
the eye, but as they involve the oxidization of the carbon and available
hydrogen and the absorption of the oxygen by unsaturated hydrocarbons,
they are the chief cause of the weathering losses in heat value. Numerous
experiments have led to the conclusion that this is also the cause for
spontaneous combustion.
Experiments to show loss in calorific heat values due to weathering indicate
that such loss may be as high as 10 per cent when the coal is stored in the air,
and 8.75 per cent when stored under water. It would appear that the higher
the volatile content of the coal, the greater will be the loss in calorific value
and the more subject to spontaneous ignition.
Some experiments made by Messrs. S. W. Parr and W. F. Wheeler, published
in 1909 by the Experiment Station of the University of Illinois, indicate that
coals of the nature found in Illinois and neighboring states are not affected
seriously during storage from the standpoint of weight and heating value, the
latter loss averaging about 3½ per cent for the first year of storage. They
Page 237
found that the losses due to disintegration and to spontaneous ignition were
of greater importance. Their conclusions agree with those deduced from the
other experiments, viz., that the storing of a larger size coal than that which
is to be used, will overcome to a certain extent the objection to
disintegration, and that the larger sizes, besides being advantageous in
respect to disintegration, are less liable to spontaneous ignition. Storage
under water will, of course, entirely prevent any fire loss and, to a great
extent, will stop disintegration and reduce the calorific losses to a minimum.
To minimize the danger of spontaneous ignition in storing coal, the piles
should be thoroughly ventilated.
Pulverized Fuels—Considerable experimental work has been done with
pulverized coal, utilizing either coal dust or pulverizing such coal as is too
small to be burned in other ways. If satisfactorily fed to the furnace, it would
appear to have several advantages. The dust burned in suspension would be
more completely consumed than is the case with the solid coals, the
production of smoke would be [Pg 171] minimized, and the process would
admit of an adjustment of the air supply to a point very close to the amount
theoretically required. This is due to the fact that in burning there is an
intimate mixture of the air and fuel. The principal objections have been in
the inability to introduce the pulverized fuel into the furnace uniformly, the
difficulty of reducing the fuel to the same degree of fineness, liability of
explosion in the furnace due to improper mixture with the air, and the
decreased capacity and efficiency resulting from the difficulty of keeping
tube surfaces clean.
Pressed Fuels—In this class are those composed of the dust of some suitable
combustible, pressed and cemented together by a substance possessing
binding and in most cases inflammable properties. Such fuels, known as
briquettes, are extensively used in foreign countries and consist of carbon or
soft coal, too small to be burned in the ordinary way, mixed usually with
pitch or coal tar. Much experimenting has been done in this country in
briquetting fuels, the government having taken an active interest in the
question, but as yet this class of fuel has not come into common use as the
cost and difficulty of manufacture and handling have made it impossible to
place it in the market at a price to successfully compete with coal.
of greater importance. Their conclusions agree with those deduced from the
other experiments, viz., that the storing of a larger size coal than that which
is to be used, will overcome to a certain extent the objection to
disintegration, and that the larger sizes, besides being advantageous in
respect to disintegration, are less liable to spontaneous ignition. Storage
under water will, of course, entirely prevent any fire loss and, to a great
extent, will stop disintegration and reduce the calorific losses to a minimum.
To minimize the danger of spontaneous ignition in storing coal, the piles
should be thoroughly ventilated.
Pulverized Fuels—Considerable experimental work has been done with
pulverized coal, utilizing either coal dust or pulverizing such coal as is too
small to be burned in other ways. If satisfactorily fed to the furnace, it would
appear to have several advantages. The dust burned in suspension would be
more completely consumed than is the case with the solid coals, the
production of smoke would be [Pg 171] minimized, and the process would
admit of an adjustment of the air supply to a point very close to the amount
theoretically required. This is due to the fact that in burning there is an
intimate mixture of the air and fuel. The principal objections have been in
the inability to introduce the pulverized fuel into the furnace uniformly, the
difficulty of reducing the fuel to the same degree of fineness, liability of
explosion in the furnace due to improper mixture with the air, and the
decreased capacity and efficiency resulting from the difficulty of keeping
tube surfaces clean.
Pressed Fuels—In this class are those composed of the dust of some suitable
combustible, pressed and cemented together by a substance possessing
binding and in most cases inflammable properties. Such fuels, known as
briquettes, are extensively used in foreign countries and consist of carbon or
soft coal, too small to be burned in the ordinary way, mixed usually with
pitch or coal tar. Much experimenting has been done in this country in
briquetting fuels, the government having taken an active interest in the
question, but as yet this class of fuel has not come into common use as the
cost and difficulty of manufacture and handling have made it impossible to
place it in the market at a price to successfully compete with coal.
Page 238
Coke is a porous product consisting almost entirely of carbon remaining
after certain manufacturing processes have distilled off the hydrocarbon
gases of the fuel used. It is produced, first, from gas coal distilled in gas
retorts; second, from gas or ordinary bituminous coals burned in special
furnaces called coke ovens; and third, from petroleum by carrying the
distillation of the residuum to a red heat.
Coke is a smokeless fuel. It readily absorbs moisture from the atmosphere
and if not kept under cover its moisture content may be as much as 20 per
cent of its own weight.
Gas-house coke is generally softer and more porous than oven coke, ignites
more readily, and requires less draft for its combustion.
[Pg 172]
16,000 Horse-power Installation of Babcock & Wilcox Boilers and
Superheaters at the Brunot’s Island Plant of the Duquesne Light Co.,
Pittsburgh, Pa.
FOOTNOTES
after certain manufacturing processes have distilled off the hydrocarbon
gases of the fuel used. It is produced, first, from gas coal distilled in gas
retorts; second, from gas or ordinary bituminous coals burned in special
furnaces called coke ovens; and third, from petroleum by carrying the
distillation of the residuum to a red heat.
Coke is a smokeless fuel. It readily absorbs moisture from the atmosphere
and if not kept under cover its moisture content may be as much as 20 per
cent of its own weight.
Gas-house coke is generally softer and more porous than oven coke, ignites
more readily, and requires less draft for its combustion.
[Pg 172]
16,000 Horse-power Installation of Babcock & Wilcox Boilers and
Superheaters at the Brunot’s Island Plant of the Duquesne Light Co.,
Pittsburgh, Pa.
FOOTNOTES
Page 239
[33] The Panther Creek District forms a part of what is known as the Southern
Field; in the matter of hardness, however, these coals are more nearly akin to
Lehigh coals.
[34] Sometimes called Western Middle or Northern Schuylkill Field.
[35] Geographically, the Shamokin District is part of the Western Middle
Mahanoy Field, but the coals found in this section resemble more closely those of
the Wyoming Field.
Field; in the matter of hardness, however, these coals are more nearly akin to
Lehigh coals.
[34] Sometimes called Western Middle or Northern Schuylkill Field.
[35] Geographically, the Shamokin District is part of the Western Middle
Mahanoy Field, but the coals found in this section resemble more closely those of
the Wyoming Field.
Page 240
[Pg 173]
Page 241
THE DETERMINATION OF HEATING VALUES OF
FUELS
The heating value of a fuel may be determined either by a calculation from a chemical
analysis or by burning a sample in a calorimeter.
In the former method the calculation should be based on an ultimate analysis, which
reduces the fuel to its elementary constituents of carbon, hydrogen, oxygen, nitrogen,
sulphur, ash and moisture, to secure a reasonable degree of accuracy. A proximate
analysis, which determines only the percentage of moisture, fixed carbon, volatile matter
and ash, without determining the ultimate composition of the volatile matter, cannot be
used for computing the heat of combustion with the same degree of accuracy as an
ultimate analysis, but estimates may be based on the ultimate analysis that are fairly
correct.
An ultimate analysis requires the services of a competent chemist, and the methods to be
employed in such a determination will be found in any standard book on engineering
chemistry. An ultimate analysis, while resolving the fuel into its elementary constituents,
does not reveal how these may have been combined in the fuel. The manner of their
combination undoubtedly has a direct effect upon their calorific value, as fuels having
almost identical ultimate analyses show a difference in heating value when tested in a
calorimeter. Such a difference, however, is slight, and very close approximations may be
computed from the ultimate analysis.
Ultimate analyses are given on both a moist and a dry fuel basis. Inasmuch as the latter is
the basis generally accepted for the comparison of data, it would appear that it is the best
basis on which to report such an analysis. When an analysis is given on a moist fuel basis
it may be readily converted to a dry basis by dividing the percentages of the various
constituents by one minus the percentage of moisture, reporting the moisture content
separately.
Moist Fuel Dry Fuel
C 83.95 84.45
H 4.23 4.25
O 3.02 3.04
N 1.27 1.28
S .91 .91
Ash 6.03 6.07
–––––––––––
100.00
FUELS
The heating value of a fuel may be determined either by a calculation from a chemical
analysis or by burning a sample in a calorimeter.
In the former method the calculation should be based on an ultimate analysis, which
reduces the fuel to its elementary constituents of carbon, hydrogen, oxygen, nitrogen,
sulphur, ash and moisture, to secure a reasonable degree of accuracy. A proximate
analysis, which determines only the percentage of moisture, fixed carbon, volatile matter
and ash, without determining the ultimate composition of the volatile matter, cannot be
used for computing the heat of combustion with the same degree of accuracy as an
ultimate analysis, but estimates may be based on the ultimate analysis that are fairly
correct.
An ultimate analysis requires the services of a competent chemist, and the methods to be
employed in such a determination will be found in any standard book on engineering
chemistry. An ultimate analysis, while resolving the fuel into its elementary constituents,
does not reveal how these may have been combined in the fuel. The manner of their
combination undoubtedly has a direct effect upon their calorific value, as fuels having
almost identical ultimate analyses show a difference in heating value when tested in a
calorimeter. Such a difference, however, is slight, and very close approximations may be
computed from the ultimate analysis.
Ultimate analyses are given on both a moist and a dry fuel basis. Inasmuch as the latter is
the basis generally accepted for the comparison of data, it would appear that it is the best
basis on which to report such an analysis. When an analysis is given on a moist fuel basis
it may be readily converted to a dry basis by dividing the percentages of the various
constituents by one minus the percentage of moisture, reporting the moisture content
separately.
Moist Fuel Dry Fuel
C 83.95 84.45
H 4.23 4.25
O 3.02 3.04
N 1.27 1.28
S .91 .91
Ash 6.03 6.07
–––––––––––
100.00
Page 242
Moisture .59 .59
–––––––––––
100.00
Calculations from an Ultimate Analysis—The first formula for the calculation of heating
values from the composition of a fuel as determined from an ultimate analysis is due to
Dulong, and this formula, slightly modified, is the most commonly used to-day. Other
formulae have been proposed, some of which are more accurate for certain specific classes
of fuel, but all have their basis in Dulong’s formula, the accepted modified form of which
is:
Heat units in B. t. u. per pound of dry fuel =
O
(
14,600 C + 62,000 H - ––––
8
) + 4000 S (18)
[Pg 174]
where C, H, O and S are the proportionate parts by weight of carbon, hydrogen, oxygen
and sulphur.
Assume a coal of the composition given. Substituting in this formula (18),
Heating value per pound of dry coal
.0304
= 14,600 × .8445 + 62,000( .0425 - ––––––––– ) + 4000 × .0091 = 14,765 B. t. u.
8
This coal, by a calorimetric test, showed 14,843 B. t. u., and from a comparison the degree
of accuracy of the formula will be noted.
The investigation of Lord and Haas in this country, Mabler in France, and Bunte in
Germany, all show that Dulong’s formula gives results nearly identical with those obtained
from calorimetric tests and may be safely applied to all solid fuels except cannel coal,
lignite, turf and wood, provided the ultimate analysis is correct. This practically limits its
use to coal. The limiting features are the presence of hydrogen and carbon united in the
form of hydrocarbons. Such hydrocarbons are present in coals in small quantities, but they
have positive and negative heats of combination, and in coals these appear to offset each
other, certainly sufficiently to apply the formula to such fuels.
High and Low Heat Value of Fuels—In any fuel containing hydrogen the calorific value
as found by the calorimeter is higher than that obtainable under most working conditions
–––––––––––
100.00
Calculations from an Ultimate Analysis—The first formula for the calculation of heating
values from the composition of a fuel as determined from an ultimate analysis is due to
Dulong, and this formula, slightly modified, is the most commonly used to-day. Other
formulae have been proposed, some of which are more accurate for certain specific classes
of fuel, but all have their basis in Dulong’s formula, the accepted modified form of which
is:
Heat units in B. t. u. per pound of dry fuel =
O
(
14,600 C + 62,000 H - ––––
8
) + 4000 S (18)
[Pg 174]
where C, H, O and S are the proportionate parts by weight of carbon, hydrogen, oxygen
and sulphur.
Assume a coal of the composition given. Substituting in this formula (18),
Heating value per pound of dry coal
.0304
= 14,600 × .8445 + 62,000( .0425 - ––––––––– ) + 4000 × .0091 = 14,765 B. t. u.
8
This coal, by a calorimetric test, showed 14,843 B. t. u., and from a comparison the degree
of accuracy of the formula will be noted.
The investigation of Lord and Haas in this country, Mabler in France, and Bunte in
Germany, all show that Dulong’s formula gives results nearly identical with those obtained
from calorimetric tests and may be safely applied to all solid fuels except cannel coal,
lignite, turf and wood, provided the ultimate analysis is correct. This practically limits its
use to coal. The limiting features are the presence of hydrogen and carbon united in the
form of hydrocarbons. Such hydrocarbons are present in coals in small quantities, but they
have positive and negative heats of combination, and in coals these appear to offset each
other, certainly sufficiently to apply the formula to such fuels.
High and Low Heat Value of Fuels—In any fuel containing hydrogen the calorific value
as found by the calorimeter is higher than that obtainable under most working conditions
Page 243
in boiler practice by an amount equal to the latent heat of the volatilization of water. This
heat would reappear when the vapor was condensed, though in ordinary practice the vapor
passes away uncondensed. This fact gives rise to a distinction in heat values into the so-
called “higher” and “lower” calorific values. The higher value, i. e., the one determined by
the calorimeter, is the only scientific unit, is the value which should be used in boiler
testing work, and is the one recommended by the American Society of Mechanical
Engineers.
There is no absolute measure of the lower heat of combustion, and in view of the wide
difference in opinion among physicists as to the deductions to be made from the higher or
absolute unit in this determination, the lower value must be considered an artificial unit.
The lower value entails the use of an ultimate analysis and involves assumptions that
would make the employment of such a unit impracticable for commercial work. The use
of the low value may also lead to error and is in no way to be recommended for boiler
practice.
An example of its illogical use may be shown by the consideration of a boiler operated in
connection with a special economizer where the vapor produced by hydrogen is partially
condensed by the economizer. If the low value were used in computing the boiler
efficiency, it is obvious that the total efficiency of the combined boiler and economizer
must be in error through crediting the combination with the heat imparted in condensing
the vapor and not charging such heat to the heat value of the coal.
Heating Value of Gaseous Fuels—The method of computing calorific values from an
ultimate analysis is particularly adapted to solid fuels, with the exceptions already noted.
The heating value of gaseous fuels may be calculated by Dulong’s formula provided
another term is added to provide for any carbon monoxide present. Such a method,
however, involves the separating of the constituent gases into their elementary gases,
which is oftentimes difficult and liable to simple arithmetical error. As the combustible
portion of gaseous fuels is ordinarily composed of hydrogen, carbon [Pg 175] monoxide and
certain hydrocarbons, a determination of the calorific value is much more readily obtained
by a separation into their constituent gases and a computation of the calorific value from a
table of such values of the constituents. Table 37 gives the calorific value of the more
common combustible gases, together with the theoretical amount of air required for their
combustion.
TABLE 37
WEIGHT AND CALORIFIC VALUE OF VARIOUS GASES
AT 32 DEGREES FAHRENHEIT AND ATMOSPHERIC PRESSURE
WITH THEORETICAL AMOUNT OF AIR REQUIRED FOR COMBUSTION
Gas Symbol Cubic Feet B. t. u. B. t. u. Cubic Feet Cubic Feet of
of per per of Air Required
Pound Air Per Cubic
heat would reappear when the vapor was condensed, though in ordinary practice the vapor
passes away uncondensed. This fact gives rise to a distinction in heat values into the so-
called “higher” and “lower” calorific values. The higher value, i. e., the one determined by
the calorimeter, is the only scientific unit, is the value which should be used in boiler
testing work, and is the one recommended by the American Society of Mechanical
Engineers.
There is no absolute measure of the lower heat of combustion, and in view of the wide
difference in opinion among physicists as to the deductions to be made from the higher or
absolute unit in this determination, the lower value must be considered an artificial unit.
The lower value entails the use of an ultimate analysis and involves assumptions that
would make the employment of such a unit impracticable for commercial work. The use
of the low value may also lead to error and is in no way to be recommended for boiler
practice.
An example of its illogical use may be shown by the consideration of a boiler operated in
connection with a special economizer where the vapor produced by hydrogen is partially
condensed by the economizer. If the low value were used in computing the boiler
efficiency, it is obvious that the total efficiency of the combined boiler and economizer
must be in error through crediting the combination with the heat imparted in condensing
the vapor and not charging such heat to the heat value of the coal.
Heating Value of Gaseous Fuels—The method of computing calorific values from an
ultimate analysis is particularly adapted to solid fuels, with the exceptions already noted.
The heating value of gaseous fuels may be calculated by Dulong’s formula provided
another term is added to provide for any carbon monoxide present. Such a method,
however, involves the separating of the constituent gases into their elementary gases,
which is oftentimes difficult and liable to simple arithmetical error. As the combustible
portion of gaseous fuels is ordinarily composed of hydrogen, carbon [Pg 175] monoxide and
certain hydrocarbons, a determination of the calorific value is much more readily obtained
by a separation into their constituent gases and a computation of the calorific value from a
table of such values of the constituents. Table 37 gives the calorific value of the more
common combustible gases, together with the theoretical amount of air required for their
combustion.
TABLE 37
WEIGHT AND CALORIFIC VALUE OF VARIOUS GASES
AT 32 DEGREES FAHRENHEIT AND ATMOSPHERIC PRESSURE
WITH THEORETICAL AMOUNT OF AIR REQUIRED FOR COMBUSTION
Gas Symbol Cubic Feet B. t. u. B. t. u. Cubic Feet Cubic Feet of
of per per of Air Required
Pound Air Per Cubic
Page 244
Gas per Cubic Required Foot
Pound Foot per Pound of Gas
of
Gas
Hydrogen H 177.90 62000 349 428.25 2.41
Carbon
CO 2.81 4450 347 30.60 2.39
Monoxide
Methane CH4 22.37 23550 1053 214.00 9.57
Acetylene C2H2 13.79 21465 1556 164.87 11.93
Olefiant Gas C2H4 12.80 21440 1675 183.60 14.33
Ethane C2H6 11.94 22230 1862 199.88 16.74
In applying this table, as gas analyses may be reported either by weight or volume, there is
given in Table 33[36] a method of changing from volumetric analysis to analysis by weight.
Examples:
1st. Assume a blast furnace gas, the analysis of which in percentages by weight is, oxygen
= 2.7, carbon monoxide = 19.5, carbon dioxide = 18.7, nitrogen = 59.1. Here the only
combustible gas is the carbon monoxide, and the heat value will be,
0.195 × 4450 = 867.75 B. t. u. per pound.
The net volume of air required to burn one pound of this gas will be,
0.195 × 30.6 = 5.967 cubic feet.
2nd. Assume a natural gas, the analysis of which in percentages by volume is oxygen =
0.40, carbon monoxide = 0.95, carbon dioxide = 0.34, olefiant gas (C2H4) = 0.66, ethane
(C2H6) = 3.55, marsh gas (CH4) = 72.15 and hydrogen = 21.95. All but the oxygen and the
carbon dioxide are combustibles, and the heat per cubic foot will be,
From CO = 0.0095 × 347 = 3.30
C2H4 = 0.0066 × 1675 = 11.05
C2H6 = 0.0355 × 1862 = 66.10
CH4 = 0.7215 × 1050 = 757.58
H = 0.2195 × 349 = 76.61
–––––––––––
B. t. u. per cubic foot = 914.64
[Pg 176]
The net air required for combustion of one cubic foot of the gas will be,
Pound Foot per Pound of Gas
of
Gas
Hydrogen H 177.90 62000 349 428.25 2.41
Carbon
CO 2.81 4450 347 30.60 2.39
Monoxide
Methane CH4 22.37 23550 1053 214.00 9.57
Acetylene C2H2 13.79 21465 1556 164.87 11.93
Olefiant Gas C2H4 12.80 21440 1675 183.60 14.33
Ethane C2H6 11.94 22230 1862 199.88 16.74
In applying this table, as gas analyses may be reported either by weight or volume, there is
given in Table 33[36] a method of changing from volumetric analysis to analysis by weight.
Examples:
1st. Assume a blast furnace gas, the analysis of which in percentages by weight is, oxygen
= 2.7, carbon monoxide = 19.5, carbon dioxide = 18.7, nitrogen = 59.1. Here the only
combustible gas is the carbon monoxide, and the heat value will be,
0.195 × 4450 = 867.75 B. t. u. per pound.
The net volume of air required to burn one pound of this gas will be,
0.195 × 30.6 = 5.967 cubic feet.
2nd. Assume a natural gas, the analysis of which in percentages by volume is oxygen =
0.40, carbon monoxide = 0.95, carbon dioxide = 0.34, olefiant gas (C2H4) = 0.66, ethane
(C2H6) = 3.55, marsh gas (CH4) = 72.15 and hydrogen = 21.95. All but the oxygen and the
carbon dioxide are combustibles, and the heat per cubic foot will be,
From CO = 0.0095 × 347 = 3.30
C2H4 = 0.0066 × 1675 = 11.05
C2H6 = 0.0355 × 1862 = 66.10
CH4 = 0.7215 × 1050 = 757.58
H = 0.2195 × 349 = 76.61
–––––––––––
B. t. u. per cubic foot = 914.64
[Pg 176]
The net air required for combustion of one cubic foot of the gas will be,
Page 245
CO = 0.0095 × 2.39 = 0.02
C2H4 = 0.0066 × 14.33 = 0.09
C2H6 = 0.0355 × 16.74 = 0.59
CH4 = 0.7215 × 9.57 = 6.90
H = 0.2195 × 2.41 = 0.53
–––––––
Total net air per cubic foot = 8.13
Proximate Analysis—The proximate analysis of a fuel gives its proportions by weight of
fixed carbon, volatile combustible matter, moisture and ash. A method of making such an
analysis which has been found to give eminently satisfactory results is described below.
From the coal sample obtained on the boiler trial, an average sample of approximately 40
grams is broken up and weighed. A good means of reducing such a sample is passing it
through an ordinary coffee mill. This sample should be placed in a double-walled air bath,
which should be kept at an approximately constant temperature of 105 degrees centigrade,
the sample being weighed at intervals until a minimum is reached. The percentage of
moisture can be calculated from the loss in such a drying.
For the determination of the remainder of the analysis, and the heating value of the fuel, a
portion of this dried sample should be thoroughly pulverized, and if it is to be kept, should
be placed in an air-tight receptacle. One gram of the pulverized sample should be weighed
into a porcelain crucible equipped with a well fitting lid. This crucible should be supported
on a platinum triangle and heated for seven minutes over the full flame of a Bunsen
burner. At the end of such time the sample should be placed in a desiccator containing
calcium chloride, and when cooled should be weighed. From the loss the percentage of
volatile combustible matter may be readily calculated.
The same sample from which the volatile matter has been driven should be used in the
determination of the percentage of ash. This percentage is obtained by burning the fixed
carbon over a Bunsen burner or in a muffle furnace. The burning should be kept up until a
constant weight is secured, and it may be assisted by stirring with a platinum rod. The
weight of the residue determines the percentage of ash, and the percentage of fixed carbon
is easily calculated from the loss during the determination of ash after the volatile matter
has been driven off.
Proximate analyses may be made and reported on a moist or dry basis. The dry basis is
that ordinarily accepted, and this is the basis adopted throughout this book. The method of
converting from a moist to a dry basis is the same as described in the case of an ultimate
analysis. A proximate analysis is easily made, gives information as to the general
characteristics of a fuel and of its relative heating value.
Table 38 gives the proximate analysis and calorific value of a number of representative
coals found in the United States.
C2H4 = 0.0066 × 14.33 = 0.09
C2H6 = 0.0355 × 16.74 = 0.59
CH4 = 0.7215 × 9.57 = 6.90
H = 0.2195 × 2.41 = 0.53
–––––––
Total net air per cubic foot = 8.13
Proximate Analysis—The proximate analysis of a fuel gives its proportions by weight of
fixed carbon, volatile combustible matter, moisture and ash. A method of making such an
analysis which has been found to give eminently satisfactory results is described below.
From the coal sample obtained on the boiler trial, an average sample of approximately 40
grams is broken up and weighed. A good means of reducing such a sample is passing it
through an ordinary coffee mill. This sample should be placed in a double-walled air bath,
which should be kept at an approximately constant temperature of 105 degrees centigrade,
the sample being weighed at intervals until a minimum is reached. The percentage of
moisture can be calculated from the loss in such a drying.
For the determination of the remainder of the analysis, and the heating value of the fuel, a
portion of this dried sample should be thoroughly pulverized, and if it is to be kept, should
be placed in an air-tight receptacle. One gram of the pulverized sample should be weighed
into a porcelain crucible equipped with a well fitting lid. This crucible should be supported
on a platinum triangle and heated for seven minutes over the full flame of a Bunsen
burner. At the end of such time the sample should be placed in a desiccator containing
calcium chloride, and when cooled should be weighed. From the loss the percentage of
volatile combustible matter may be readily calculated.
The same sample from which the volatile matter has been driven should be used in the
determination of the percentage of ash. This percentage is obtained by burning the fixed
carbon over a Bunsen burner or in a muffle furnace. The burning should be kept up until a
constant weight is secured, and it may be assisted by stirring with a platinum rod. The
weight of the residue determines the percentage of ash, and the percentage of fixed carbon
is easily calculated from the loss during the determination of ash after the volatile matter
has been driven off.
Proximate analyses may be made and reported on a moist or dry basis. The dry basis is
that ordinarily accepted, and this is the basis adopted throughout this book. The method of
converting from a moist to a dry basis is the same as described in the case of an ultimate
analysis. A proximate analysis is easily made, gives information as to the general
characteristics of a fuel and of its relative heating value.
Table 38 gives the proximate analysis and calorific value of a number of representative
coals found in the United States.
Page 246
[Pg 177]
TABLE 38
APPROXIMATE COMPOSITION AND CALORIFIC VALUE OF CERTAIN TYPICAL
AMERICAN COALS
B. t.
Proximate Analysis (Dry
u.
Coal)
Field, Bed Per
State County Mine Size Authority
or Vein Pound
Volatile Fixed
Moisture Ash Dry
Matter Carbon
Coal
ANTHRACITES
Beaver
Pa. Carbon Lehigh 1.50 2.41 90.30 7.29 Gale
Meadow
Pa. Dauphin Schuylkill Buckwheat 2.15 12.88 78.23 8.89 13137 Whitham
No. 2
Pa. Lackawanna Wyoming Belleview 8.29 7.81 77.19 15.00 12341 Sadtler
Buck.
Pa. Lackawanna Wyoming Johnson Culm. 13.90 11.16 65.96 22.88 10591 B. & W. Co.
No. 2
Pa. Luzerne Wyoming Pittston 3.66 4.40 78.96 16.64 12865 B. & W. Co.
Buck.
Pa. Luzerne Wyoming Mammoth Large 4.00 3.44 90.59 5.97 13720 Carpenter
Pa. Luzerne Wyoming Exeter Rice 0.25 8.18 79.61 12.21 12400 B. & W. Co.
Pa. Northumberland Schuylkill Treverton 0.84 6.73 86.39 6.88 Isherwood
Buck
Pa. Schuylkill Schuylkill 3.17 92.41 4.42 14220 Carpenter
Mountain
Pa. Schuylkill York Farm Buckwheat 0.81 5.51 75.90 18.59 11430
Pa. Victoria Buckwheat 4.30 0.55 86.73 12.72 12642 B. & W. Co.
Lehigh & Buck. &
Pa. Carbon Lehigh 1.57 6.27 66.53 27.20 12848 B. & W. Co.
Wilkes C. Co. Pea
Pa. Carbon Lehigh Buckwheat 5.00 81.00 14.00 11800 Carpenter
Del. & Hud. No. 1
Pa. Lackawanna 6.20 11.60 12100 Denton
Co. Buck.
SEMI-ANTHRACITES
Pa. Lycoming Loyalsock 1.30 8.72 84.44 6.84
Pa. Sullivan Lopez 5.48 7.53 81.00 11.47 13547 B. & W. Co.
Pa. Sullivan Bernice 1.29 8.21 84.43 7.36
SEMI-BITUMINOUS
Big Vein,
Md. Alleghany 3.50 21.33 72.47 6.20 14682 B. & W. Co.
George's Crk.
George's
Md. Alleghany 3.63 16.27 76.93 6.80 14695 B. & W. Co.
Creek
George's
Md. Alleghany 2.28 19.43 77.44 6.13 14793 B. & W. Co.
Creek
George's
Md. Alleghany Ocean No. 7 Mine run 1.13 14451 B. & W. Co.
Creek
Md. Alleghany Cumberland 1.50 17.26 76.65 6.09 14700
Washington U. S. Geo. S.
Md. Garrett Mine run 2.33 14.38 74.93 10.49 14033
No. 3 [37]
Pa. Bradford Long Valley 1.55 20.33 68.38 11.29 12965
Pa. Tioga Antrim 2.19 18.43 71.87 9.70 13500
Soriman Shaft
Pa. Cambria "B" or Miller 3.40 20.70 71.84 7.46 14484 N. Y. Ed. Co.
C. Co.
Pa. Cambria "B" or Miller Henrietta 1.23 18.37 75.28 6.45 14770 So. Eng. Co.
TABLE 38
APPROXIMATE COMPOSITION AND CALORIFIC VALUE OF CERTAIN TYPICAL
AMERICAN COALS
B. t.
Proximate Analysis (Dry
u.
Coal)
Field, Bed Per
State County Mine Size Authority
or Vein Pound
Volatile Fixed
Moisture Ash Dry
Matter Carbon
Coal
ANTHRACITES
Beaver
Pa. Carbon Lehigh 1.50 2.41 90.30 7.29 Gale
Meadow
Pa. Dauphin Schuylkill Buckwheat 2.15 12.88 78.23 8.89 13137 Whitham
No. 2
Pa. Lackawanna Wyoming Belleview 8.29 7.81 77.19 15.00 12341 Sadtler
Buck.
Pa. Lackawanna Wyoming Johnson Culm. 13.90 11.16 65.96 22.88 10591 B. & W. Co.
No. 2
Pa. Luzerne Wyoming Pittston 3.66 4.40 78.96 16.64 12865 B. & W. Co.
Buck.
Pa. Luzerne Wyoming Mammoth Large 4.00 3.44 90.59 5.97 13720 Carpenter
Pa. Luzerne Wyoming Exeter Rice 0.25 8.18 79.61 12.21 12400 B. & W. Co.
Pa. Northumberland Schuylkill Treverton 0.84 6.73 86.39 6.88 Isherwood
Buck
Pa. Schuylkill Schuylkill 3.17 92.41 4.42 14220 Carpenter
Mountain
Pa. Schuylkill York Farm Buckwheat 0.81 5.51 75.90 18.59 11430
Pa. Victoria Buckwheat 4.30 0.55 86.73 12.72 12642 B. & W. Co.
Lehigh & Buck. &
Pa. Carbon Lehigh 1.57 6.27 66.53 27.20 12848 B. & W. Co.
Wilkes C. Co. Pea
Pa. Carbon Lehigh Buckwheat 5.00 81.00 14.00 11800 Carpenter
Del. & Hud. No. 1
Pa. Lackawanna 6.20 11.60 12100 Denton
Co. Buck.
SEMI-ANTHRACITES
Pa. Lycoming Loyalsock 1.30 8.72 84.44 6.84
Pa. Sullivan Lopez 5.48 7.53 81.00 11.47 13547 B. & W. Co.
Pa. Sullivan Bernice 1.29 8.21 84.43 7.36
SEMI-BITUMINOUS
Big Vein,
Md. Alleghany 3.50 21.33 72.47 6.20 14682 B. & W. Co.
George's Crk.
George's
Md. Alleghany 3.63 16.27 76.93 6.80 14695 B. & W. Co.
Creek
George's
Md. Alleghany 2.28 19.43 77.44 6.13 14793 B. & W. Co.
Creek
George's
Md. Alleghany Ocean No. 7 Mine run 1.13 14451 B. & W. Co.
Creek
Md. Alleghany Cumberland 1.50 17.26 76.65 6.09 14700
Washington U. S. Geo. S.
Md. Garrett Mine run 2.33 14.38 74.93 10.49 14033
No. 3 [37]
Pa. Bradford Long Valley 1.55 20.33 68.38 11.29 12965
Pa. Tioga Antrim 2.19 18.43 71.87 9.70 13500
Soriman Shaft
Pa. Cambria "B" or Miller 3.40 20.70 71.84 7.46 14484 N. Y. Ed. Co.
C. Co.
Pa. Cambria "B" or Miller Henrietta 1.23 18.37 75.28 6.45 14770 So. Eng. Co.
Page 247
Pa. Cambria "B" or Miller Penker 3.64 21.34 70.48 8.18 14401 B. & W. Co.
Pa. Cambria "B" or Miller Lancashire 4.38 21.20 70.27 8.53 14453 B. & W. Co.
Lower Penn. C. & C.
Pa. Cambria Mine run 3.51 17.43 75.69 6.88 14279 U. S. Geo. S.
Kittanning Co. No. 3
Upper
Pa. Cambria Valley Mine run 3.40 14.89 75.03 10.08 14152 B. & W. Co.
Kittanning
Lower
Pa. Clearfield Eureka Mine run 5.90 16.71 77.22 6.07 14843 U. S. Geo. S.
Kittanning
Pa. Clearfield Ghem Mine run 3.43 17.53 69.67 12.80 13744 B. & W. Co.
Pa. Clearfield Osceola 1.24 25.43 68.56 6.01 13589 B. & W. Co.
Pa. Clearfield Reynoldsville 2.91 21.55 69.03 9.42 14685 B. & W. Co.
Atlantic-
Pa. Clearfield Mine run 1.55 23.36 71.15 5.94 13963 Whitham
Clearfield
Barnet &
Pa. Huntington Carbon Mine run 4.50 18.34 73.06 8.60 13770 B. & W. Co.
Fulton
Pa. Huntington Rock Hill Mine run 5.91 17.58 73.44 8.99 14105 B. & W. Co.
Lower
Pa. Somerset Kimmelton Mine run 3.09 17.84 70.47 11.69 13424 U. S. Geo. S.
Kittanning
"C" Prime
Pa. Somerset Jenner Mine run 9.37 16.47 75.76 7.77 14507 P. R. R.
Vein
U. S. Geo. S.
W. Va. Fayette New River Rush Run Mine run 2.14 22.87 71.56 5.57 14959
[Pg 178]
W. Va. Fayette New River Loup Creek 0.55 19.36 78.48 2.16 14975 Hill
W. Va. Fayette New River Slack 6.66 20.94 73.16 5.90 14412 B. & W. Co.
W. Va. Fayette New River Mine run 2.16 17.82 75.66 6.52 14786 B. & W. Co.
W. Va. Fayette New River Rush Run Mine run 0.94 22.16 75.85 1.99 15007 B. & W. Co.
Pocahontas
W. Va. McDowell Zenith Mine run 4.85 17.14 76.54 6.32 14480 U. S. Geo. S.
No. 3
W. Va. McDowell Tug River Big Sandy Mine run 1.58 18.55 76.44 4.91 15170 U. S. Geo. S.
W. Va. Mercer Pocahontas Mora Lump 1.74 18.55 75.15 6.30 15015 U. S. Geo. S.
W. Va. Mineral Elk Garden 2.10 15.70 75.40 8.90 14195 B. & W. Co.
W. Va. McDowell Pocahontas Flat Top Mine run 0.52 24.02 74.59 1.39 14490 B. & W. Co.
W. Va. McDowell Pocahontas Flat Top Slack 3.24 15.33 77.60 7.07 14653 B. & W. Co.
W. Va. McDowell Pocahontas Flat Top Lump 3.63 16.03 78.04 5.93 14956 B. & W. Co.
B. t.
Proximate Analysis (Dry
u.
Coal)
Field, Bed Per
State County Mine Size Authority
or Vein Pound
Volatile Fixed
Moisture Ash Dry
Matter Carbon
Coal
BITUMINOUS
Ala. Bibb Cahaba Hill Creek Mine run 6.19 28.58 55.60 15.82 12576 B. & W. Co.
Ala. Jefferson Pratt Pratt No. 13 4.29 25.78 67.68 6.54 14482 B. & W. Co.
Ala. Jefferson Pratt Warner Mine run 2.51 27.80 61.50 10.70 13628 U. S. Geo. S.
Ala. Jefferson Coalburg Mine run 0.94 31.34 65.65 3.01 14513 B. & W. Co.
Ivy C. & I.
Ala. Walker Horse Creek Nut 2.56 31.82 53.89 14.29 12937 U. S. Geo. S.
Co. No. 8
Galloway C.
Ala. Walker Jagger Mine run 4.83 34.65 51.12 14.03 12976 U. S. Geo. S.
Co. No. 5
Ark. Franklin Denning Western No. 4 Nut 2.22 12.83 75.35 11.82 U. S. Geo. S.
Ark. Sebastian Jenny Lind Mine No. 12 Lump 1.07 17.04 74.45 8.51 14252 U. S. Geo. S.
Ark. Sebastian Huntington Cherokee Mine run 0.97 19.87 70.30 9.83 14159 U. S. Geo. S.
Col. Boulder South Platte Lafayette Mine run 19.48 38.80 49.00 12.20 11939 B. & W. Co.
Col. Boulder Laramie Simson Mine run 19.78 44.69 48.62 6.69 12577 U. S. Geo. S.
Pa. Cambria "B" or Miller Lancashire 4.38 21.20 70.27 8.53 14453 B. & W. Co.
Lower Penn. C. & C.
Pa. Cambria Mine run 3.51 17.43 75.69 6.88 14279 U. S. Geo. S.
Kittanning Co. No. 3
Upper
Pa. Cambria Valley Mine run 3.40 14.89 75.03 10.08 14152 B. & W. Co.
Kittanning
Lower
Pa. Clearfield Eureka Mine run 5.90 16.71 77.22 6.07 14843 U. S. Geo. S.
Kittanning
Pa. Clearfield Ghem Mine run 3.43 17.53 69.67 12.80 13744 B. & W. Co.
Pa. Clearfield Osceola 1.24 25.43 68.56 6.01 13589 B. & W. Co.
Pa. Clearfield Reynoldsville 2.91 21.55 69.03 9.42 14685 B. & W. Co.
Atlantic-
Pa. Clearfield Mine run 1.55 23.36 71.15 5.94 13963 Whitham
Clearfield
Barnet &
Pa. Huntington Carbon Mine run 4.50 18.34 73.06 8.60 13770 B. & W. Co.
Fulton
Pa. Huntington Rock Hill Mine run 5.91 17.58 73.44 8.99 14105 B. & W. Co.
Lower
Pa. Somerset Kimmelton Mine run 3.09 17.84 70.47 11.69 13424 U. S. Geo. S.
Kittanning
"C" Prime
Pa. Somerset Jenner Mine run 9.37 16.47 75.76 7.77 14507 P. R. R.
Vein
U. S. Geo. S.
W. Va. Fayette New River Rush Run Mine run 2.14 22.87 71.56 5.57 14959
[Pg 178]
W. Va. Fayette New River Loup Creek 0.55 19.36 78.48 2.16 14975 Hill
W. Va. Fayette New River Slack 6.66 20.94 73.16 5.90 14412 B. & W. Co.
W. Va. Fayette New River Mine run 2.16 17.82 75.66 6.52 14786 B. & W. Co.
W. Va. Fayette New River Rush Run Mine run 0.94 22.16 75.85 1.99 15007 B. & W. Co.
Pocahontas
W. Va. McDowell Zenith Mine run 4.85 17.14 76.54 6.32 14480 U. S. Geo. S.
No. 3
W. Va. McDowell Tug River Big Sandy Mine run 1.58 18.55 76.44 4.91 15170 U. S. Geo. S.
W. Va. Mercer Pocahontas Mora Lump 1.74 18.55 75.15 6.30 15015 U. S. Geo. S.
W. Va. Mineral Elk Garden 2.10 15.70 75.40 8.90 14195 B. & W. Co.
W. Va. McDowell Pocahontas Flat Top Mine run 0.52 24.02 74.59 1.39 14490 B. & W. Co.
W. Va. McDowell Pocahontas Flat Top Slack 3.24 15.33 77.60 7.07 14653 B. & W. Co.
W. Va. McDowell Pocahontas Flat Top Lump 3.63 16.03 78.04 5.93 14956 B. & W. Co.
B. t.
Proximate Analysis (Dry
u.
Coal)
Field, Bed Per
State County Mine Size Authority
or Vein Pound
Volatile Fixed
Moisture Ash Dry
Matter Carbon
Coal
BITUMINOUS
Ala. Bibb Cahaba Hill Creek Mine run 6.19 28.58 55.60 15.82 12576 B. & W. Co.
Ala. Jefferson Pratt Pratt No. 13 4.29 25.78 67.68 6.54 14482 B. & W. Co.
Ala. Jefferson Pratt Warner Mine run 2.51 27.80 61.50 10.70 13628 U. S. Geo. S.
Ala. Jefferson Coalburg Mine run 0.94 31.34 65.65 3.01 14513 B. & W. Co.
Ivy C. & I.
Ala. Walker Horse Creek Nut 2.56 31.82 53.89 14.29 12937 U. S. Geo. S.
Co. No. 8
Galloway C.
Ala. Walker Jagger Mine run 4.83 34.65 51.12 14.03 12976 U. S. Geo. S.
Co. No. 5
Ark. Franklin Denning Western No. 4 Nut 2.22 12.83 75.35 11.82 U. S. Geo. S.
Ark. Sebastian Jenny Lind Mine No. 12 Lump 1.07 17.04 74.45 8.51 14252 U. S. Geo. S.
Ark. Sebastian Huntington Cherokee Mine run 0.97 19.87 70.30 9.83 14159 U. S. Geo. S.
Col. Boulder South Platte Lafayette Mine run 19.48 38.80 49.00 12.20 11939 B. & W. Co.
Col. Boulder Laramie Simson Mine run 19.78 44.69 48.62 6.69 12577 U. S. Geo. S.
Page 248
Nut and
Col. Fremont Canon City Chandler 9.37 38.10 51.75 10.15 11850 B. & W. Co.
Slack
Col. Las Animas Trinidad Hastings Nut 2.15 31.07 53.40 15.53 12547 B. & W. Co.
Col. Las Animas Trinidad Moreley Slack 1.88 28.47 55.58 15.95 12703 B. & W. Co.
Col. Routt Yampa Oak Creek 6.67 42.91 55.64 1.45 Hill
Ill. Christian Pana Penwell Col. Lump 8.05 43.67 49.97 6.36 10900 Jones
Ill. Franklin No. 6 Benton Egg 8.31 34.52 54.05 11.43 11727 U. S. Geo. S.
Ill. Franklin Big Muddy Zeigler ¾ inch 13.28 31.97 57.37 10.66 12857 U. S. Geo. S.
Ill. Jackson Big Muddy 4.85 31.55 62.19 6.26 11466 Breckenridge
Ill. La Salle Streator 8.40 41.76 51.42 6.82 11727 Breckenridge
Ill. La Salle Streator Marseilles Mine run 12.98 43.73 49.13 7.14 10899 B. & W. Co.
Ill. Macoupin Nilwood Mine No. 2 Screenings 13.34 34.75 44.55 20.70 10781 B. & W. Co.
Ill. Macoupin Mt. Olive Mine No. 2 Mine run 13.54 41.28 46.30 12.42 10807 U. S. Geo. S.
Ill. Madison Belleville Donk Bros. Lump 13.47 38.69 48.07 13.24 12427 U. S. Geo. S.
Ill. Madison Glen Carbon Mine run 9.78 38.18 51.52 10.30 11672 Bryan
Ill. Marion Odin Lump 6.20 42.91 49.06 8.03 11880 Breckenridge
Ill. Mercer Gilchrist Screenings 8.50 36.17 41.64 22.19 10497 Breckenridge
Ill. Montgomery Pana or No. 5 Coffeen Mine run 11.93 34.05 49.85 16.10 10303 U. S. Geo. S.
Ill. Peoria No. 5 Empire 17.64 31.91 46.17 21.92 10705 B. & W. Co.
Ill. Perry Du Quoin Number 1 Screenings 9.81 33.67 48.36 17.97 11229 B. & W. Co.
U. S. Geo. S.
Ill. Perry Du Quoin Willis Mine run 7.22 33.06 53.97 12.97 11352
[Pg 179]
Ill. Sangamon Pawnee Slack 4.81 41.53 39.62 18.85 10220 Jones
Nigger
Ill. St. Glair Standard Mine run 14.39 32.90 44.84 22.26 11059 B. & W. Co.
Hollow
Ill. St. Clair Standard Maryville Mine run 15.71 38.10 41.10 20.80 10999 B. & W. Co.
Ill. Williamson Big Muddy Daws Mine run 8.17 34.33 52.50 13.17 12643 U. S. Geo. S.
Carterville or
Ill. Williamson Carterville 4.66 35.65 56.86 7.49 12286 Univ. of Ill.
No. 7
Carterville or Nut, Pea
Ill. Williamson Burr 11.91 33.70 55.90 10.40 12932 B. & W. Co.
No. 7 and Slack
Ind. Brazil Brazil Gartside Block 2.83 40.03 51.97 8.00 13375 Stillman
Ind. Clay Louise Block 0.83 39.70 52.28 8.02 13248 Jones
Ind. Green Island City Mine run 6.17 35.42 53.55 11.03 11916 Dearborn
Ind. Knox Vein No. 5 Tecumseh Mine run 10.73 35.75 54.46 9.79 12911 B. & W. Co.
Parke Coal
Ind. Parke Vein No. 6 Lump 10.72 44.02 46.33 9.65 11767 U. S. Geo. S.
Co.
Ind. Sullivan Sullivan No. 6 Mildred Washed 16.59 42.17 48.44 9.59 13377 U. S. Geo. S.
Ind. Vigo Number 6 Fontanet Mine run 2.28 34.95 50.50 14.55 11920 Dearborn
B. t.
Proximate Analysis (Dry
u.
Coal)
Field, Bed Per
State County Mine Size Authority
or Vein Pound
Volatile Fixed
Moisture Ash Dry
Matter Carbon
Coal
Ind. Vigo Number 7 Red Bird Mine run 11.62 41.17 46.76 12.07 12740 U. S. Geo. S.
Iowa Appanoose Mystic Mine No. 3 Lump 13.48 39.40 43.09 17.51 11678 U. S. Geo. S.
Iowa Lucas Lucas Inland No. 1 Mine run 16.01 37.82 46.24 15.94 11963 U. S. Geo. S.
Iowa Marion Big Vein Liberty No. 5 Mine run 14.88 41.53 39.63 18.84 11443 U. S. Geo. S.
Iowa Polk Third Seam Altoona No. 4 Lump 12.44 41.27 40.86 17.87 11671 U. S. Geo. S.
Iowa Wapello Wapello Lump 8.69 36.23 43.68 20.09 11443 U. S. Geo. S.
Weir Southwestern
Kan. Cherokee Lump 4.31 33.88 53.67 12.45 13144 U. S. Geo. S.
Pittsburgh Dev. Co.
Kan. Cherokee Cherokee Screenings 6.16 35.56 46.90 17.54 10175 Jones
Kan. Cherokee Cherokee Lump 1.81 34.77 52.77 12.46 12557 Jones
Col. Fremont Canon City Chandler 9.37 38.10 51.75 10.15 11850 B. & W. Co.
Slack
Col. Las Animas Trinidad Hastings Nut 2.15 31.07 53.40 15.53 12547 B. & W. Co.
Col. Las Animas Trinidad Moreley Slack 1.88 28.47 55.58 15.95 12703 B. & W. Co.
Col. Routt Yampa Oak Creek 6.67 42.91 55.64 1.45 Hill
Ill. Christian Pana Penwell Col. Lump 8.05 43.67 49.97 6.36 10900 Jones
Ill. Franklin No. 6 Benton Egg 8.31 34.52 54.05 11.43 11727 U. S. Geo. S.
Ill. Franklin Big Muddy Zeigler ¾ inch 13.28 31.97 57.37 10.66 12857 U. S. Geo. S.
Ill. Jackson Big Muddy 4.85 31.55 62.19 6.26 11466 Breckenridge
Ill. La Salle Streator 8.40 41.76 51.42 6.82 11727 Breckenridge
Ill. La Salle Streator Marseilles Mine run 12.98 43.73 49.13 7.14 10899 B. & W. Co.
Ill. Macoupin Nilwood Mine No. 2 Screenings 13.34 34.75 44.55 20.70 10781 B. & W. Co.
Ill. Macoupin Mt. Olive Mine No. 2 Mine run 13.54 41.28 46.30 12.42 10807 U. S. Geo. S.
Ill. Madison Belleville Donk Bros. Lump 13.47 38.69 48.07 13.24 12427 U. S. Geo. S.
Ill. Madison Glen Carbon Mine run 9.78 38.18 51.52 10.30 11672 Bryan
Ill. Marion Odin Lump 6.20 42.91 49.06 8.03 11880 Breckenridge
Ill. Mercer Gilchrist Screenings 8.50 36.17 41.64 22.19 10497 Breckenridge
Ill. Montgomery Pana or No. 5 Coffeen Mine run 11.93 34.05 49.85 16.10 10303 U. S. Geo. S.
Ill. Peoria No. 5 Empire 17.64 31.91 46.17 21.92 10705 B. & W. Co.
Ill. Perry Du Quoin Number 1 Screenings 9.81 33.67 48.36 17.97 11229 B. & W. Co.
U. S. Geo. S.
Ill. Perry Du Quoin Willis Mine run 7.22 33.06 53.97 12.97 11352
[Pg 179]
Ill. Sangamon Pawnee Slack 4.81 41.53 39.62 18.85 10220 Jones
Nigger
Ill. St. Glair Standard Mine run 14.39 32.90 44.84 22.26 11059 B. & W. Co.
Hollow
Ill. St. Clair Standard Maryville Mine run 15.71 38.10 41.10 20.80 10999 B. & W. Co.
Ill. Williamson Big Muddy Daws Mine run 8.17 34.33 52.50 13.17 12643 U. S. Geo. S.
Carterville or
Ill. Williamson Carterville 4.66 35.65 56.86 7.49 12286 Univ. of Ill.
No. 7
Carterville or Nut, Pea
Ill. Williamson Burr 11.91 33.70 55.90 10.40 12932 B. & W. Co.
No. 7 and Slack
Ind. Brazil Brazil Gartside Block 2.83 40.03 51.97 8.00 13375 Stillman
Ind. Clay Louise Block 0.83 39.70 52.28 8.02 13248 Jones
Ind. Green Island City Mine run 6.17 35.42 53.55 11.03 11916 Dearborn
Ind. Knox Vein No. 5 Tecumseh Mine run 10.73 35.75 54.46 9.79 12911 B. & W. Co.
Parke Coal
Ind. Parke Vein No. 6 Lump 10.72 44.02 46.33 9.65 11767 U. S. Geo. S.
Co.
Ind. Sullivan Sullivan No. 6 Mildred Washed 16.59 42.17 48.44 9.59 13377 U. S. Geo. S.
Ind. Vigo Number 6 Fontanet Mine run 2.28 34.95 50.50 14.55 11920 Dearborn
B. t.
Proximate Analysis (Dry
u.
Coal)
Field, Bed Per
State County Mine Size Authority
or Vein Pound
Volatile Fixed
Moisture Ash Dry
Matter Carbon
Coal
Ind. Vigo Number 7 Red Bird Mine run 11.62 41.17 46.76 12.07 12740 U. S. Geo. S.
Iowa Appanoose Mystic Mine No. 3 Lump 13.48 39.40 43.09 17.51 11678 U. S. Geo. S.
Iowa Lucas Lucas Inland No. 1 Mine run 16.01 37.82 46.24 15.94 11963 U. S. Geo. S.
Iowa Marion Big Vein Liberty No. 5 Mine run 14.88 41.53 39.63 18.84 11443 U. S. Geo. S.
Iowa Polk Third Seam Altoona No. 4 Lump 12.44 41.27 40.86 17.87 11671 U. S. Geo. S.
Iowa Wapello Wapello Lump 8.69 36.23 43.68 20.09 11443 U. S. Geo. S.
Weir Southwestern
Kan. Cherokee Lump 4.31 33.88 53.67 12.45 13144 U. S. Geo. S.
Pittsburgh Dev. Co.
Kan. Cherokee Cherokee Screenings 6.16 35.56 46.90 17.54 10175 Jones
Kan. Cherokee Cherokee Lump 1.81 34.77 52.77 12.46 12557 Jones
Page 249
Kan. Linn Boicourt Lump 4.74 36.59 47.07 16.34 10392 Jones
Str. Ck. C. &
Ky. Bell Straight Creek Mine run 2.89 36.67 57.24 6.09 14362 U. S. Geo. S.
C. Co.
Ky. Hopkins Bed No. 9 Earlington Lump 6.89 40.30 55.16 4.54 13381 St. Col. Ky.
Ky. Hopkins Bed No. 9 Barnsley Mine run 7.92 40.53 48.70 10.77 13036 U. S. Geo. S.
Pea and
Ky. Hopkins Vein No. 14 Nebo 8.02 31.91 54.02 14.07 12448 B. & W. Co.
Slack
Ky. Johnson Vein No. 1 Miller's Creek Mine run 5.12 38.46 58.63 2.91 13743 U. S. Geo. S.
Pea and
Ky. Mulenburg Bed No. 9 Pierce 9.22 33.94 52.18 13.88 12229 B. & W. Co.
Slack
Ky. Pulaski Greensburg 2.80 26.54 63.58 9.88 14095 N. Y. Ed. Co.
Pea and
Ky. Webster Bed No. 9 7.30 31.08 60.72 8.20 13600 B. & W. Co.
Slack
Nut and
Ky. Whitley Jellico 3.82 31.82 58.78 9.40 13175 B. & W. Co.
Slack
Mo. Adair Danforth Mine run 9.00 30.55 46.26 23.19 9889 B. & W. Co.
Mo. Bates Rich Hill New Home Mine run 7.28 37.62 43.83 18.55 12109 U. S. Geo. S.
Mo. City Coal
Mo. Clay Lexington 12.45 39.39 48.47 12.14 12875 Univ. of Mo.
Co.
Mo. Lafayette Waverly Buckthorn 8.58 41.78 45.99 12.23 12735 Univ. of Mo.
Mo. Lafayette Waverly Higbee 10.84 31.72 55.29 12.99 12500 Univ. of Mo.
Mo. Linn Bevier Marceline 9.45 36.72 52.20 11.08 13180 Univ. of Mo.
Northwest
Mo. Macon Bevier 13.09 37.83 42.95 19.22 11500 U. S. Geo. S.
Coal Co.
Morgan Co.
Mo. Morgan Morgan Co. Mine run 12.24 45.69 47.98 6.33 14197 U. S. Geo. S.
Coal Co.
Mendotta No.
Mo. Putnam Mendotta 20.78 39.36 50.00 10.64 12602 U. S. Geo. S.
8
Pea and
N.Mex. McKinley Gallup Gibson 12.17 36.31 51.17 12.52 12126 B. & W. Co.
Slack
Hocking
Ohio Athens Sunday Creek Slack 12.16 34.64 53.10 12.26 12214 [Pg 180]
Valley
Pittsburgh No.
Ohio Belmont Neff Coal Co. Mine run 5.31 38.78 52.22 9.00 12843 U. S. Geo. S.
8
Middle
Ohio Columbiana Palestine 2.15 37.57 51.80 10.63 13370 Lord & Haas
Kittanning
Middle
Ohio Coshocton Morgan Run Mine run 41.76 45.24 13.00 13239 B. & W. Co.
Kittanning
Ohio Guernsey Vein No. 7 Little Kate 6.19 33.02 59.96 7.02 13634 B. & W. Co.
Hocking
Ohio Hocking Lump 6.45 39.12 50.08 10.80 12700 Lord & Haas
Valley
Hocking
Ohio Hocking 2.60 40.80 47.60 11.60 12175 Jones
Valley
Superior Coal
Ohio Jackson Brookville Mine run 7.59 38.45 43.99 17.56 11704 U. S. Geo. S.
Co.
Lower Superior Coal
Ohio Jackson Mine run 8.99 41.43 50.06 8.51 13113 U. S. Geo. S.
Kittanning Co.
Ohio Jackson Quakertown Wellston 3.38 35.26 54.18 7.56 12506 Hill
Pittsburgh or
Ohio Jefferson Crow Hollow ¾ inch 4.04 40.08 52.27 9.65 13374 U. S. Geo. S.
No. 8
Pittsburgh or Rush Run No.
Ohio Jefferson ¾ inch 4.74 36.08 54.81 9.11 13532 U. S. Geo. S.
No. 8 1
Ohio Perry Hocking Congo 6 41 38.33 46.71 14.96 12284 B. & W. Co.
Ohio Stark Massillon Slack 6.67 40.02 46.46 13.52 11860 B. & W. Co.
Brookville or Nut and
Ohio Vinton Clarion 2.47 42.38 50.39 6.23 13421 U. S. Geo. S.
No. 4 Slack
Str. Ck. C. &
Ky. Bell Straight Creek Mine run 2.89 36.67 57.24 6.09 14362 U. S. Geo. S.
C. Co.
Ky. Hopkins Bed No. 9 Earlington Lump 6.89 40.30 55.16 4.54 13381 St. Col. Ky.
Ky. Hopkins Bed No. 9 Barnsley Mine run 7.92 40.53 48.70 10.77 13036 U. S. Geo. S.
Pea and
Ky. Hopkins Vein No. 14 Nebo 8.02 31.91 54.02 14.07 12448 B. & W. Co.
Slack
Ky. Johnson Vein No. 1 Miller's Creek Mine run 5.12 38.46 58.63 2.91 13743 U. S. Geo. S.
Pea and
Ky. Mulenburg Bed No. 9 Pierce 9.22 33.94 52.18 13.88 12229 B. & W. Co.
Slack
Ky. Pulaski Greensburg 2.80 26.54 63.58 9.88 14095 N. Y. Ed. Co.
Pea and
Ky. Webster Bed No. 9 7.30 31.08 60.72 8.20 13600 B. & W. Co.
Slack
Nut and
Ky. Whitley Jellico 3.82 31.82 58.78 9.40 13175 B. & W. Co.
Slack
Mo. Adair Danforth Mine run 9.00 30.55 46.26 23.19 9889 B. & W. Co.
Mo. Bates Rich Hill New Home Mine run 7.28 37.62 43.83 18.55 12109 U. S. Geo. S.
Mo. City Coal
Mo. Clay Lexington 12.45 39.39 48.47 12.14 12875 Univ. of Mo.
Co.
Mo. Lafayette Waverly Buckthorn 8.58 41.78 45.99 12.23 12735 Univ. of Mo.
Mo. Lafayette Waverly Higbee 10.84 31.72 55.29 12.99 12500 Univ. of Mo.
Mo. Linn Bevier Marceline 9.45 36.72 52.20 11.08 13180 Univ. of Mo.
Northwest
Mo. Macon Bevier 13.09 37.83 42.95 19.22 11500 U. S. Geo. S.
Coal Co.
Morgan Co.
Mo. Morgan Morgan Co. Mine run 12.24 45.69 47.98 6.33 14197 U. S. Geo. S.
Coal Co.
Mendotta No.
Mo. Putnam Mendotta 20.78 39.36 50.00 10.64 12602 U. S. Geo. S.
8
Pea and
N.Mex. McKinley Gallup Gibson 12.17 36.31 51.17 12.52 12126 B. & W. Co.
Slack
Hocking
Ohio Athens Sunday Creek Slack 12.16 34.64 53.10 12.26 12214 [Pg 180]
Valley
Pittsburgh No.
Ohio Belmont Neff Coal Co. Mine run 5.31 38.78 52.22 9.00 12843 U. S. Geo. S.
8
Middle
Ohio Columbiana Palestine 2.15 37.57 51.80 10.63 13370 Lord & Haas
Kittanning
Middle
Ohio Coshocton Morgan Run Mine run 41.76 45.24 13.00 13239 B. & W. Co.
Kittanning
Ohio Guernsey Vein No. 7 Little Kate 6.19 33.02 59.96 7.02 13634 B. & W. Co.
Hocking
Ohio Hocking Lump 6.45 39.12 50.08 10.80 12700 Lord & Haas
Valley
Hocking
Ohio Hocking 2.60 40.80 47.60 11.60 12175 Jones
Valley
Superior Coal
Ohio Jackson Brookville Mine run 7.59 38.45 43.99 17.56 11704 U. S. Geo. S.
Co.
Lower Superior Coal
Ohio Jackson Mine run 8.99 41.43 50.06 8.51 13113 U. S. Geo. S.
Kittanning Co.
Ohio Jackson Quakertown Wellston 3.38 35.26 54.18 7.56 12506 Hill
Pittsburgh or
Ohio Jefferson Crow Hollow ¾ inch 4.04 40.08 52.27 9.65 13374 U. S. Geo. S.
No. 8
Pittsburgh or Rush Run No.
Ohio Jefferson ¾ inch 4.74 36.08 54.81 9.11 13532 U. S. Geo. S.
No. 8 1
Ohio Perry Hocking Congo 6 41 38.33 46.71 14.96 12284 B. & W. Co.
Ohio Stark Massillon Slack 6.67 40.02 46.46 13.52 11860 B. & W. Co.
Brookville or Nut and
Ohio Vinton Clarion 2.47 42.38 50.39 6.23 13421 U. S. Geo. S.
No. 4 Slack
Page 250
B. t.
Proximate Analysis (Dry
u.
Coal)
Field, Bed Per
State County Mine Size Authority
or Vein Pound
Volatile Fixed
Moisture Ash Dry
Matter Carbon
Coal
Edwards No.
Okla. Choctaw McAlester Mine run 4.79 39.18 49.97 10.85 13005 U. S. Geo. S.
1
Okla. Choctaw McAlester Adamson Slack 4.72 28.54 58.17 13.29 12105 B. & W. Co.
Lump and
Okla. Creek Henrietta 7.65 36.77 50.14 13.09 12834 U. S. Geo. S.
Slack
Pittsburgh 3rd
Pa. Allegheny Slack 1.77 32.06 57.11 10.83 13205 Carpenter
Pool
Pa. Allegheny Monongahela Turtle Creek 1.75 36.85 53.94 9.21 13480 Lord & Haas
Pa. Allegheny Pittsburgh Bertha ¾ inch 2.61 35.86 57.81 6.33 13997 U. S. Geo. S.
Pa. Cambria Beach Creek Slack 3.01 32.87 55.86 11.27 13755 B. & W. Co.
Pa. Cambria Miller Lincoln Mine run 5.39 30.83 61.05 8.12 13600 B. & W. Co.
Lower
Pa. Clarion 0.54 35.93 57.66 6.41 13547
Freeport
Pa. Fayette Connellsville Slack 1.85 28.73 63.22 7.95 13775 Whitham
Pa. Greene Youghiogheny Lump 1.25 32.60 54.70 12.70 13100 B. & W. Co.
Pa. Greene Westmoreland Screenings 11.12 31.67 55.61 12.72 13100 P. R. R.
Pa. Indiana Iselin Mine run 2.70 29.33 63.56 7.11 14220 B. & W. Co.
Pa. Jefferson Punxsutawney Mine run 3.38 29.33 64.93 5.73 14781 B. & W. Co.
Middle
Pa. Lawrence 0.70 37.06 56.24 6.70 13840 Lord & Haas
Kittanning
Pa. Mercer Taylor 4.18 32.19 55.55 12.26 12820 B. & W. Co.
Pa. Washington Pittsburgh Ellsworth 2.46 35.35 58.46 6.19 14013 U. S. Geo. S.
Pa. Washington Youghiogheny Anderson ¾ inch 1.00 39.29 54.80 5.91 13729 Jones
Pa. Westmoreland Pittsburgh Scott Haven Lump 4.06 32.91 59.78 7.31 13934 B. & W. Co.
Tenn. Campbell Jellico 1.80 37.76 62.12 1.12 13846 U. S. Navy
Tenn. Claiborne Mingo 4.40 34.31 59.22 6.47 U. S. Geo. S.
Tenn. Marion Etna 3.16 32.98 56.59 10.43
Tenn. Morgan Brushy Mt. 1.77 33.46 54.73 11.87 13824 B. & W. Co.
Glen Mary Ky. State
Tenn. Scott Glen Mary 1.53 40.80 56.78 2.42 14625
No. 4 Col.
Tex. Maverick Eagle Pass 5.42 33.73 44.89 21.38 10945 B. & W. Co.
Tex. Paolo Pinto Thurber Mine run 1.90 36.01 49.09 14.90 12760 B. & W. Co.
Tex. Paolo Pinto Strawn Mine run 4.19 35.40 52.98 11.62 13202 B. & W. Co.
Va. Henrico Gayton 0.82 17.14 74.92 7.94 14363 B. & W. Co.
U. S. Geo. S.
Va. Lee Darby Darby 1½ inch 4.35 38.46 56.91 4.63 13939
[Pg 181]
Va. Lee McConnel Wilson Mine run 3.35 36.35 57.88 5.77 13931 U. S. Geo. S.
Va. Wise Upper Banner Coburn 3½ inch 3.05 32.65 62.73 4.62 14470 U. S. Geo. S.
Va. Rockingham Clover Hill 31.77 57.98 10.25 13103
Va. Russel Clinchfield 2.00 35.72 56.12 8.16 14200
Va. Monongahela Bernmont 32.00 59.90 8.10 13424 Carpenter
W. Va. Harrison Pittsburgh Ocean Mine run 2.47 39.35 52.78 7.87 14202 U. S. Geo. S.
Nut, Pea
W. Va. Harrison Girard 36.66 57.49 5.85 14548 B. & W. Co.
and Slack
W. Va. Kanawha Winifrede Winifrede 1.05 32.74 64.38 2.88 14111 Hill
W. Va. Kanawha Keystone Keystone Mine run 2.21 33.29 58.61 8.10 14202 U. S. Geo. S.
Nut and
W. Va. Logan Island Creek 1.12 38.61 55.91 5.48 14273 Hill
Slack
W. Va. Marion Fairmont Kingmont 1.90 35.31 57.34 7.35 14198 U. S. Geo. S.
Proximate Analysis (Dry
u.
Coal)
Field, Bed Per
State County Mine Size Authority
or Vein Pound
Volatile Fixed
Moisture Ash Dry
Matter Carbon
Coal
Edwards No.
Okla. Choctaw McAlester Mine run 4.79 39.18 49.97 10.85 13005 U. S. Geo. S.
1
Okla. Choctaw McAlester Adamson Slack 4.72 28.54 58.17 13.29 12105 B. & W. Co.
Lump and
Okla. Creek Henrietta 7.65 36.77 50.14 13.09 12834 U. S. Geo. S.
Slack
Pittsburgh 3rd
Pa. Allegheny Slack 1.77 32.06 57.11 10.83 13205 Carpenter
Pool
Pa. Allegheny Monongahela Turtle Creek 1.75 36.85 53.94 9.21 13480 Lord & Haas
Pa. Allegheny Pittsburgh Bertha ¾ inch 2.61 35.86 57.81 6.33 13997 U. S. Geo. S.
Pa. Cambria Beach Creek Slack 3.01 32.87 55.86 11.27 13755 B. & W. Co.
Pa. Cambria Miller Lincoln Mine run 5.39 30.83 61.05 8.12 13600 B. & W. Co.
Lower
Pa. Clarion 0.54 35.93 57.66 6.41 13547
Freeport
Pa. Fayette Connellsville Slack 1.85 28.73 63.22 7.95 13775 Whitham
Pa. Greene Youghiogheny Lump 1.25 32.60 54.70 12.70 13100 B. & W. Co.
Pa. Greene Westmoreland Screenings 11.12 31.67 55.61 12.72 13100 P. R. R.
Pa. Indiana Iselin Mine run 2.70 29.33 63.56 7.11 14220 B. & W. Co.
Pa. Jefferson Punxsutawney Mine run 3.38 29.33 64.93 5.73 14781 B. & W. Co.
Middle
Pa. Lawrence 0.70 37.06 56.24 6.70 13840 Lord & Haas
Kittanning
Pa. Mercer Taylor 4.18 32.19 55.55 12.26 12820 B. & W. Co.
Pa. Washington Pittsburgh Ellsworth 2.46 35.35 58.46 6.19 14013 U. S. Geo. S.
Pa. Washington Youghiogheny Anderson ¾ inch 1.00 39.29 54.80 5.91 13729 Jones
Pa. Westmoreland Pittsburgh Scott Haven Lump 4.06 32.91 59.78 7.31 13934 B. & W. Co.
Tenn. Campbell Jellico 1.80 37.76 62.12 1.12 13846 U. S. Navy
Tenn. Claiborne Mingo 4.40 34.31 59.22 6.47 U. S. Geo. S.
Tenn. Marion Etna 3.16 32.98 56.59 10.43
Tenn. Morgan Brushy Mt. 1.77 33.46 54.73 11.87 13824 B. & W. Co.
Glen Mary Ky. State
Tenn. Scott Glen Mary 1.53 40.80 56.78 2.42 14625
No. 4 Col.
Tex. Maverick Eagle Pass 5.42 33.73 44.89 21.38 10945 B. & W. Co.
Tex. Paolo Pinto Thurber Mine run 1.90 36.01 49.09 14.90 12760 B. & W. Co.
Tex. Paolo Pinto Strawn Mine run 4.19 35.40 52.98 11.62 13202 B. & W. Co.
Va. Henrico Gayton 0.82 17.14 74.92 7.94 14363 B. & W. Co.
U. S. Geo. S.
Va. Lee Darby Darby 1½ inch 4.35 38.46 56.91 4.63 13939
[Pg 181]
Va. Lee McConnel Wilson Mine run 3.35 36.35 57.88 5.77 13931 U. S. Geo. S.
Va. Wise Upper Banner Coburn 3½ inch 3.05 32.65 62.73 4.62 14470 U. S. Geo. S.
Va. Rockingham Clover Hill 31.77 57.98 10.25 13103
Va. Russel Clinchfield 2.00 35.72 56.12 8.16 14200
Va. Monongahela Bernmont 32.00 59.90 8.10 13424 Carpenter
W. Va. Harrison Pittsburgh Ocean Mine run 2.47 39.35 52.78 7.87 14202 U. S. Geo. S.
Nut, Pea
W. Va. Harrison Girard 36.66 57.49 5.85 14548 B. & W. Co.
and Slack
W. Va. Kanawha Winifrede Winifrede 1.05 32.74 64.38 2.88 14111 Hill
W. Va. Kanawha Keystone Keystone Mine run 2.21 33.29 58.61 8.10 14202 U. S. Geo. S.
Nut and
W. Va. Logan Island Creek 1.12 38.61 55.91 5.48 14273 Hill
Slack
W. Va. Marion Fairmont Kingmont 1.90 35.31 57.34 7.35 14198 U. S. Geo. S.
Page 251
W. Va. Mingo Thacker Maritime 0.68 31.89 63.48 4.63 14126 Hill
W. Va. Mingo Glen Alum Glen Alum Mine run 3.02 33.81 59.45 6.74 14414 U. S. Geo. S.
W. Va. Preston Bakerstown 4.14 29.09 63.50 7.41 14546 U. S. Geo. S.
W. Va. Putnam Pittsburgh Black Betsy Bug dust 7.41 32.84 53.96 13.20 12568 B. & W. Co.
Upper Lump and
W. Va. Randolph Coalton 2.11 29.57 59.93 10.50 13854 U. S. Geo. S.
Freeport Nut
B. t.
Proximate Analysis (Dry
u.
Coal)
Field, Bed Per
State County Mine Size Authority
or Vein Pound
Volatile Fixed
Moisture Ash Dry
Matter Carbon
Coal
LIGNITES AND LIGNITIC COALS
Col. Boulder Rex 16.05 42.12 47.97 9.91 10678 B. & W. Co.
Col. El Paso Curtis 23.25 42.11 49.38 8.51 11090 B. & W. Co.
Col. El Paso Pike View 23.77 48.70 41.47 9.83 10629 B. & W. Co.
Col. Gunnison South Platte Mt. Carbon 20.38 46.38 47.50 6.12
Col. Sc. of
Col. Las Animas Acme 16.74 47.90 44.60 7.50
M.
Col. Lehigh 18.30 45.29 44.67 10.04
N.
McLean Eckland Mine run 29.65 45.56 47.05 7.39 10553 Lord
Dak.
N.
McLean Wilton Lump 35.96 49.84 38.05 12.11 11036 U. S. Geo. S.
Dak.
N.
McLean Casino 29.65 46.56 38.70 14.74 Lord
Dak.
N.
Stark Lehigh Lehigh Mine run 35.84 43.84 39.59 16.57 10121 U. S. Geo. S.
Dak.
N.
William Williston Mine run 41.76 39.37 48.09 12.54 10121 B. & W. Co.
Dak.
N.
William Williston Mine run 42.74 40.83 47.79 11.38 10271 B. & W. Co.
Dak.
Tex. Bastrop Bastrop Glenham 32.77 42.76 36.88 20.36 8958 B. & W. Co.
Tex. Houston Crockett 23.27 40.95 38.37 20.68 10886 U. S. Geo. S.
Houston C. &
Tex. Houston 31.48 46.93 34.40 18.87 10176 B. & W. Co.
C. Co.
Tex. Milam Rockdale Worley 32.48 43.04 41.14 15.82 10021 B. & W. Co.
Tex. Robertson Calvert Coaling No. 1 32.01 43.70 43.08 13.22 10753 B. & W. Co.
Consumer's
Tex. Wood Hoyt 33.98 46.97 41.40 11.63 10600 U. S. Geo. S.
Lig. Co.
Tex. Wood Hoyt 30.25 43.27 41.46 15.27 10597
Black
Wash. King 3.71 48.72 46.56 4.72 Gale
Diamond
Wyo. Carbon Hanna Mine run 6.44 51.32 43.00 5.68 11607 B. & W. Co.
Stilwell Coal
Wyo. Crook Black Hills 19.08 45.21 46.42 8.37 12641 U. S. Geo. S.
Co.
Wyo. Sheridan Sheridan Monarch 21.18 51.87 40.43 7.70 12316 U. S. Geo. S.
Wyo. Sweetwater Rock Spring Screenings 7.70 38.57 56.99 4.44 12534 B. & W. Co.
U. S. Geo. S.
Wyo. Uinta Adaville Lazeart 19.15 45.50 48.11 6.39 9868
[Pg 182]
W. Va. Mingo Glen Alum Glen Alum Mine run 3.02 33.81 59.45 6.74 14414 U. S. Geo. S.
W. Va. Preston Bakerstown 4.14 29.09 63.50 7.41 14546 U. S. Geo. S.
W. Va. Putnam Pittsburgh Black Betsy Bug dust 7.41 32.84 53.96 13.20 12568 B. & W. Co.
Upper Lump and
W. Va. Randolph Coalton 2.11 29.57 59.93 10.50 13854 U. S. Geo. S.
Freeport Nut
B. t.
Proximate Analysis (Dry
u.
Coal)
Field, Bed Per
State County Mine Size Authority
or Vein Pound
Volatile Fixed
Moisture Ash Dry
Matter Carbon
Coal
LIGNITES AND LIGNITIC COALS
Col. Boulder Rex 16.05 42.12 47.97 9.91 10678 B. & W. Co.
Col. El Paso Curtis 23.25 42.11 49.38 8.51 11090 B. & W. Co.
Col. El Paso Pike View 23.77 48.70 41.47 9.83 10629 B. & W. Co.
Col. Gunnison South Platte Mt. Carbon 20.38 46.38 47.50 6.12
Col. Sc. of
Col. Las Animas Acme 16.74 47.90 44.60 7.50
M.
Col. Lehigh 18.30 45.29 44.67 10.04
N.
McLean Eckland Mine run 29.65 45.56 47.05 7.39 10553 Lord
Dak.
N.
McLean Wilton Lump 35.96 49.84 38.05 12.11 11036 U. S. Geo. S.
Dak.
N.
McLean Casino 29.65 46.56 38.70 14.74 Lord
Dak.
N.
Stark Lehigh Lehigh Mine run 35.84 43.84 39.59 16.57 10121 U. S. Geo. S.
Dak.
N.
William Williston Mine run 41.76 39.37 48.09 12.54 10121 B. & W. Co.
Dak.
N.
William Williston Mine run 42.74 40.83 47.79 11.38 10271 B. & W. Co.
Dak.
Tex. Bastrop Bastrop Glenham 32.77 42.76 36.88 20.36 8958 B. & W. Co.
Tex. Houston Crockett 23.27 40.95 38.37 20.68 10886 U. S. Geo. S.
Houston C. &
Tex. Houston 31.48 46.93 34.40 18.87 10176 B. & W. Co.
C. Co.
Tex. Milam Rockdale Worley 32.48 43.04 41.14 15.82 10021 B. & W. Co.
Tex. Robertson Calvert Coaling No. 1 32.01 43.70 43.08 13.22 10753 B. & W. Co.
Consumer's
Tex. Wood Hoyt 33.98 46.97 41.40 11.63 10600 U. S. Geo. S.
Lig. Co.
Tex. Wood Hoyt 30.25 43.27 41.46 15.27 10597
Black
Wash. King 3.71 48.72 46.56 4.72 Gale
Diamond
Wyo. Carbon Hanna Mine run 6.44 51.32 43.00 5.68 11607 B. & W. Co.
Stilwell Coal
Wyo. Crook Black Hills 19.08 45.21 46.42 8.37 12641 U. S. Geo. S.
Co.
Wyo. Sheridan Sheridan Monarch 21.18 51.87 40.43 7.70 12316 U. S. Geo. S.
Wyo. Sweetwater Rock Spring Screenings 7.70 38.57 56.99 4.44 12534 B. & W. Co.
U. S. Geo. S.
Wyo. Uinta Adaville Lazeart 19.15 45.50 48.11 6.39 9868
[Pg 182]
Page 252
Portion of 12,080 Horse-power Installation of Babcock & Wilcox Boilers and
Superheaters at the Potomac Electric Co., Washington, D. C.
[Pg 183]
TABLE 39
SHOWING RELATION BETWEEN PROXIMATE AND ULTIMATE ANALYSES OF
COAL
Common in
Proximate Proximate
Ultimate Analysis
Analysis & Ultimate
State Field or Bed Mine
Analysis
Volatile Fixed
Carbon Hydrogen Oxygen Nitrogen Sulphur Ash Moisture
Matter Carbon
Icy Coal &
Ala. Horse Creek 31.81 53.90 72.02 4.78 6.45 1.66 .80 14.29 2.56
Iron Co., No. 8
Central C. &
Ark. Huntington 18.99 67.71 76.37 3.90 3.71 1.49 1.23 13.30 1.99
C. Co., No. 3
Clover Leaf,
Ill. Pana or No. 5 37.22 45.64 63.04 4.49 10.04 1.28 4.01 17.14 13.19
No. 1
No. 5, Warrick
Ind. Electric 41.85 44.45 68.08 4.78 7.56 1.35 4.53 13.70 9.11
Co.
No. 11, St. Bernard,
Ky. 41.10 49.60 72.22 5.06 8.44 1.33 3.65 9.30 7.76
Hopkins Co. No. 11
"B" or Lower
Pa. Eureka, No. 31 16.71 77.22 84.45 4.25 3.04 1.28 .91 6.07 .56
Kittanning
Pa. Indiana Co. 29.55 62.64 79.86 5.02 4.27 1.86 1.18 7.81 2.90
Superheaters at the Potomac Electric Co., Washington, D. C.
[Pg 183]
TABLE 39
SHOWING RELATION BETWEEN PROXIMATE AND ULTIMATE ANALYSES OF
COAL
Common in
Proximate Proximate
Ultimate Analysis
Analysis & Ultimate
State Field or Bed Mine
Analysis
Volatile Fixed
Carbon Hydrogen Oxygen Nitrogen Sulphur Ash Moisture
Matter Carbon
Icy Coal &
Ala. Horse Creek 31.81 53.90 72.02 4.78 6.45 1.66 .80 14.29 2.56
Iron Co., No. 8
Central C. &
Ark. Huntington 18.99 67.71 76.37 3.90 3.71 1.49 1.23 13.30 1.99
C. Co., No. 3
Clover Leaf,
Ill. Pana or No. 5 37.22 45.64 63.04 4.49 10.04 1.28 4.01 17.14 13.19
No. 1
No. 5, Warrick
Ind. Electric 41.85 44.45 68.08 4.78 7.56 1.35 4.53 13.70 9.11
Co.
No. 11, St. Bernard,
Ky. 41.10 49.60 72.22 5.06 8.44 1.33 3.65 9.30 7.76
Hopkins Co. No. 11
"B" or Lower
Pa. Eureka, No. 31 16.71 77.22 84.45 4.25 3.04 1.28 .91 6.07 .56
Kittanning
Pa. Indiana Co. 29.55 62.64 79.86 5.02 4.27 1.86 1.18 7.81 2.90
Page 253
W.
Fire Creek Rush Run 22.87 71.56 83.71 4.64 3.67 1.70 .71 5.57 2.14
Va.
Table 39 gives for comparison the ultimate and proximate analyses of certain of the coals
with which tests were made in the coal testing plant of the United States Geological
Survey at the Louisiana Purchase Exposition at St. Louis.
The heating value of a fuel cannot be directly computed from a proximate analysis, due to
the fact that the volatile content varies widely in different fuels in composition and in
heating value.
Some methods have been advanced for estimating the calorific value of coals from the
proximate analysis. William Kent[38] deducted from Mahler’s tests of European coals the
approximate heating value dependent upon the content of fixed carbon in the combustible.
The relation as deduced by Kent between the heat and value per pound of combustible and
the per cent of fixed carbon referred to combustible is represented graphically by Fig. 23.
Goutal gives another method of determining the heat value from a proximate analysis, in
which the carbon is given a fixed value and the heating value of the volatile matter is
considered as a function of its percentage referred to combustible. Goutal’s method checks
closely with Kent’s determinations.
All the formulae, however, for computing the calorific value of coals from a proximate
analysis are ordinarily limited to certain classes of fuels. Mr. Kent, for instance, states that
his deductions are correct within a close limit for fuels containing more than 60 per cent of
fixed carbon in the combustible, while for those containing a lower percentage, the error
may be as great as 4 per cent, either high or low.
While the use of such computations will serve where approximate results only are
required, that they are approximate should be thoroughly understood.
Calorimetry—An ultimate or a proximate analysis of a fuel is useful in [Pg 184]
determining its general characteristics, and as described on page 183, may be used in the
calculation of the approximate heating value. Where the efficiency of a boiler is to be
computed, however, this heating value should in all instances be determined accurately by
means of a fuel calorimeter.
In such an apparatus the fuel is completely burned and the heat generated by such
combustion is absorbed by water, the amount of heat being calculated from the elevation
in the temperature of the water. A calorimeter which has been accepted as the best for such
work is one in which the fuel is burned in a steel bomb filled with compressed oxygen.
The function of the oxygen, which is ordinarily under a pressure of about 25 atmospheres,
is to cause the rapid and complete combustion of the fuel sample. The fuel is ignited by
means of an electric current, allowance being made for the heat produced by such current,
and by the burning of the fuse wire.
Fire Creek Rush Run 22.87 71.56 83.71 4.64 3.67 1.70 .71 5.57 2.14
Va.
Table 39 gives for comparison the ultimate and proximate analyses of certain of the coals
with which tests were made in the coal testing plant of the United States Geological
Survey at the Louisiana Purchase Exposition at St. Louis.
The heating value of a fuel cannot be directly computed from a proximate analysis, due to
the fact that the volatile content varies widely in different fuels in composition and in
heating value.
Some methods have been advanced for estimating the calorific value of coals from the
proximate analysis. William Kent[38] deducted from Mahler’s tests of European coals the
approximate heating value dependent upon the content of fixed carbon in the combustible.
The relation as deduced by Kent between the heat and value per pound of combustible and
the per cent of fixed carbon referred to combustible is represented graphically by Fig. 23.
Goutal gives another method of determining the heat value from a proximate analysis, in
which the carbon is given a fixed value and the heating value of the volatile matter is
considered as a function of its percentage referred to combustible. Goutal’s method checks
closely with Kent’s determinations.
All the formulae, however, for computing the calorific value of coals from a proximate
analysis are ordinarily limited to certain classes of fuels. Mr. Kent, for instance, states that
his deductions are correct within a close limit for fuels containing more than 60 per cent of
fixed carbon in the combustible, while for those containing a lower percentage, the error
may be as great as 4 per cent, either high or low.
While the use of such computations will serve where approximate results only are
required, that they are approximate should be thoroughly understood.
Calorimetry—An ultimate or a proximate analysis of a fuel is useful in [Pg 184]
determining its general characteristics, and as described on page 183, may be used in the
calculation of the approximate heating value. Where the efficiency of a boiler is to be
computed, however, this heating value should in all instances be determined accurately by
means of a fuel calorimeter.
In such an apparatus the fuel is completely burned and the heat generated by such
combustion is absorbed by water, the amount of heat being calculated from the elevation
in the temperature of the water. A calorimeter which has been accepted as the best for such
work is one in which the fuel is burned in a steel bomb filled with compressed oxygen.
The function of the oxygen, which is ordinarily under a pressure of about 25 atmospheres,
is to cause the rapid and complete combustion of the fuel sample. The fuel is ignited by
means of an electric current, allowance being made for the heat produced by such current,
and by the burning of the fuse wire.
Page 254
A calorimeter of this type
which will be found to give
satisfactory results is that
of M. Pierre Mahler,
illustrated in Fig. 24 and
consisting of the following
parts:
A water jacket A, which
maintains constant
conditions outside of the
calorimeter proper, and
thus makes possible a more
accurate computation of
radiation losses.
Fig. 23. Graphic Representation of Relation between The porcelain lined steel
Heat Value Per Pound of Combustible and bomb B, in which the
Fixed Carbon in Combustible as Deduced by Wm. Kent. combustion of the fuel
takes place in compressed
oxygen.
Fig. 24. Mahler Bomb Calorimeter
[Pg 185]
The platinum pan C, for holding the fuel.
The calorimeter proper D, surrounding the bomb and containing a definite weighed
amount of water.
which will be found to give
satisfactory results is that
of M. Pierre Mahler,
illustrated in Fig. 24 and
consisting of the following
parts:
A water jacket A, which
maintains constant
conditions outside of the
calorimeter proper, and
thus makes possible a more
accurate computation of
radiation losses.
Fig. 23. Graphic Representation of Relation between The porcelain lined steel
Heat Value Per Pound of Combustible and bomb B, in which the
Fixed Carbon in Combustible as Deduced by Wm. Kent. combustion of the fuel
takes place in compressed
oxygen.
Fig. 24. Mahler Bomb Calorimeter
[Pg 185]
The platinum pan C, for holding the fuel.
The calorimeter proper D, surrounding the bomb and containing a definite weighed
amount of water.
Page 255
An electrode E, connecting with the fuse wire F, for igniting the fuel placed in the pan C.
A support G, for a water agitator.
A thermometer I, for temperature determination of the water in the calorimeter. The
thermometer is best supported by a stand independent of the calorimeter, so that it may not
be moved by tremors in the parts of the calorimeter, which would render the making of
readings difficult. To obtain accuracy of readings, they should be made through a
telescope or eyeglass.
A spring and screw device for revolving the agitator.
A lever L, by the movement of which the agitator is revolved.
A pressure gauge M, for noting the amount of oxygen admitted to the bomb. Between 20
and 25 atmospheres are ordinarily employed.
An oxygen tank O.
A battery or batteries P, the current from which heats the fuse wire used to ignite the fuel.
This or a similar calorimeter is used in the determination of the heat of combustion of
solid or liquid fuels. Whatever the fuel to be tested, too much importance cannot be given
to the securing of an average sample. Where coal is to be tested, tests should be made
from a portion of the dried and pulverized laboratory sample, the methods of obtaining
which have been described. In considering the methods of calorimeter determination, the
remarks applied to coal are equally applicable to any solid fuel, and such changes in
methods as are necessary for liquid fuels will be self-evident from the same description.
Approximately one gram of the pulverized dried coal sample should be placed directly in
the pan of the calorimeter. There is some danger in the using of a pulverized sample from
the fact that some of it may be blown out of the pan when oxygen is admitted. This may be
at least partially overcome by forming about two grams into a briquette by the use of a
cylinder equipped with a plunger and a screw press. Such a briquette should be broken and
approximately one gram used. If a pulverized sample is used, care should be taken to
admit oxygen slowly to prevent blowing the coal out of the pan. The weight of the sample
is limited to approximately one gram since the calorimeter is proportioned for the
combustion of about this weight when under an oxygen pressure of about 25 atmospheres.
A piece of fine iron wire is connected to the lower end of the plunger to form a fuse for
igniting the sample. The weight of iron wire used is determined, and if after combustion a
portion has not been burned, the weight of such portion is determined. In placing the
sample in the pan, and in adjusting the fuse, the top of the calorimeter is removed. It is
then replaced and carefully screwed into place on the bomb by means of a long handled
wrench furnished for the purpose.
A support G, for a water agitator.
A thermometer I, for temperature determination of the water in the calorimeter. The
thermometer is best supported by a stand independent of the calorimeter, so that it may not
be moved by tremors in the parts of the calorimeter, which would render the making of
readings difficult. To obtain accuracy of readings, they should be made through a
telescope or eyeglass.
A spring and screw device for revolving the agitator.
A lever L, by the movement of which the agitator is revolved.
A pressure gauge M, for noting the amount of oxygen admitted to the bomb. Between 20
and 25 atmospheres are ordinarily employed.
An oxygen tank O.
A battery or batteries P, the current from which heats the fuse wire used to ignite the fuel.
This or a similar calorimeter is used in the determination of the heat of combustion of
solid or liquid fuels. Whatever the fuel to be tested, too much importance cannot be given
to the securing of an average sample. Where coal is to be tested, tests should be made
from a portion of the dried and pulverized laboratory sample, the methods of obtaining
which have been described. In considering the methods of calorimeter determination, the
remarks applied to coal are equally applicable to any solid fuel, and such changes in
methods as are necessary for liquid fuels will be self-evident from the same description.
Approximately one gram of the pulverized dried coal sample should be placed directly in
the pan of the calorimeter. There is some danger in the using of a pulverized sample from
the fact that some of it may be blown out of the pan when oxygen is admitted. This may be
at least partially overcome by forming about two grams into a briquette by the use of a
cylinder equipped with a plunger and a screw press. Such a briquette should be broken and
approximately one gram used. If a pulverized sample is used, care should be taken to
admit oxygen slowly to prevent blowing the coal out of the pan. The weight of the sample
is limited to approximately one gram since the calorimeter is proportioned for the
combustion of about this weight when under an oxygen pressure of about 25 atmospheres.
A piece of fine iron wire is connected to the lower end of the plunger to form a fuse for
igniting the sample. The weight of iron wire used is determined, and if after combustion a
portion has not been burned, the weight of such portion is determined. In placing the
sample in the pan, and in adjusting the fuse, the top of the calorimeter is removed. It is
then replaced and carefully screwed into place on the bomb by means of a long handled
wrench furnished for the purpose.
Page 256
The bomb is then placed in the calorimeter, which has been filled with a definite amount
of water. This weight is the “water equivalent” of the apparatus, i. e., the weight of water,
the temperature of which would be increased one degree for an equivalent increase in the
temperature of the combined apparatus. It may be determined by calculation from the
weights and specific heats of the various parts of [Pg 186] the apparatus. Such a
determination is liable to error, however, as the weight of the bomb lining can only be
approximated, and a considerable portion of the apparatus is not submerged. Another
method of making such a determination is by the adding of definite weights of warm water
to definite amounts of cooler water in the calorimeter and taking an average of a number
of experiments. The best method for the making of such a determination is probably the
burning of a definite amount of resublimed naphthaline whose heat of combustion is
known.
The temperature of the water in the water jacket of the calorimeter should be
approximately that of the surrounding atmosphere. The temperature of the weighed
amount of water in the calorimeter is made by some experimenters slightly greater than
that of the surrounding air in order that the initial correction for radiation will be in the
same direction as the final correction. Other experimenters start from a temperature the
same or slightly lower than the temperature of the room, on the basis that the temperature
after combustion will be slightly higher than the room temperature and the radiation
correction be either a minimum or entirely eliminated.
While no experiments have been made to show conclusively which of these methods is the
better, the latter is generally used.
After the bomb has been placed in the calorimeter, it is filled with oxygen from a tank
until the pressure reaches from 20 to 25 atmospheres. The lower pressure will be sufficient
in all but exceptional cases. Connection is then made to a current from the dry batteries in
series so arranged as to allow completion of the circuit with a switch. The current from a
lighting system should not be used for ignition, as there is danger from sparking in burning
the fuse, which may effect the results. The apparatus is then ready for the test.
Unquestionably the best method of taking data is by the use of co-ordinate paper and a
plotting of the data with temperatures and time intervals as ordinates and abscissae. Such a
graphic representation is shown in Fig. 25.
of water. This weight is the “water equivalent” of the apparatus, i. e., the weight of water,
the temperature of which would be increased one degree for an equivalent increase in the
temperature of the combined apparatus. It may be determined by calculation from the
weights and specific heats of the various parts of [Pg 186] the apparatus. Such a
determination is liable to error, however, as the weight of the bomb lining can only be
approximated, and a considerable portion of the apparatus is not submerged. Another
method of making such a determination is by the adding of definite weights of warm water
to definite amounts of cooler water in the calorimeter and taking an average of a number
of experiments. The best method for the making of such a determination is probably the
burning of a definite amount of resublimed naphthaline whose heat of combustion is
known.
The temperature of the water in the water jacket of the calorimeter should be
approximately that of the surrounding atmosphere. The temperature of the weighed
amount of water in the calorimeter is made by some experimenters slightly greater than
that of the surrounding air in order that the initial correction for radiation will be in the
same direction as the final correction. Other experimenters start from a temperature the
same or slightly lower than the temperature of the room, on the basis that the temperature
after combustion will be slightly higher than the room temperature and the radiation
correction be either a minimum or entirely eliminated.
While no experiments have been made to show conclusively which of these methods is the
better, the latter is generally used.
After the bomb has been placed in the calorimeter, it is filled with oxygen from a tank
until the pressure reaches from 20 to 25 atmospheres. The lower pressure will be sufficient
in all but exceptional cases. Connection is then made to a current from the dry batteries in
series so arranged as to allow completion of the circuit with a switch. The current from a
lighting system should not be used for ignition, as there is danger from sparking in burning
the fuse, which may effect the results. The apparatus is then ready for the test.
Unquestionably the best method of taking data is by the use of co-ordinate paper and a
plotting of the data with temperatures and time intervals as ordinates and abscissae. Such a
graphic representation is shown in Fig. 25.
Page 257
Fig. 25. Graphic Method of Recording Bomb Calorimeter Results
After the bomb is placed in the calorimeter, and before the coal is ignited, readings of the
temperature of the water should be taken at one minute intervals for a period long enough
to insure a constant rate of change, and in this way determine the initial radiation. The coal
is then ignited by completing the circuit, the temperature at the instant the circuit is closed
being considered the temperature at the beginning of the combustion. After ignition the
readings should be taken at one-half minute intervals, though because of the rapidity of the
mercury’s rise approximate readings only may be possible for at least a minute after the
firing, such readings, however, being sufficiently accurate for this period. The one-half
minute readings should be taken [Pg 187] after ignition for five minutes, and for, say, five
minutes longer at minute intervals to determine accurately the final rate of radiation.
Fig. 25 shows the results of such readings, plotted in accordance with the method
suggested. It now remains to compute the results from this plotted data.
The radiation correction is first applied. Probably the most accurate manner of making
such correction is by the use of Pfaundler’s method, which is a modification of that of
Regnault. This assumes that in starting with an initial rate of radiation, as represented by
the inclination of the line AB, Fig. 25, and ending with a final radiation represented by the
After the bomb is placed in the calorimeter, and before the coal is ignited, readings of the
temperature of the water should be taken at one minute intervals for a period long enough
to insure a constant rate of change, and in this way determine the initial radiation. The coal
is then ignited by completing the circuit, the temperature at the instant the circuit is closed
being considered the temperature at the beginning of the combustion. After ignition the
readings should be taken at one-half minute intervals, though because of the rapidity of the
mercury’s rise approximate readings only may be possible for at least a minute after the
firing, such readings, however, being sufficiently accurate for this period. The one-half
minute readings should be taken [Pg 187] after ignition for five minutes, and for, say, five
minutes longer at minute intervals to determine accurately the final rate of radiation.
Fig. 25 shows the results of such readings, plotted in accordance with the method
suggested. It now remains to compute the results from this plotted data.
The radiation correction is first applied. Probably the most accurate manner of making
such correction is by the use of Pfaundler’s method, which is a modification of that of
Regnault. This assumes that in starting with an initial rate of radiation, as represented by
the inclination of the line AB, Fig. 25, and ending with a final radiation represented by the
Page 258
inclination of the line CD, Fig. 25, that the rate of radiation for the intermediate
temperatures between the points B and C are proportional to the initial and final rates. That
is, the rate of radiation at a point midway between B and C will be the mean between the
initial and final rates; the rate of radiation at a point three-quarters of the distance between
B and C would be the rate at B plus three-quarters of the difference in rates at B and C, etc.
This method differs from Regnault’s in that the radiation was assumed by Regnault to be
in each case proportional to the difference in temperatures between the water of the
calorimeter and the surrounding air plus a constant found for each experiment. Pfaundler’s
method is more simple than that of Regnault, and the results by the two methods are in
practical agreement.
Expressed as a formula, Pfaundler’s method is, though not in form given by him:
R' - R
(
C = N R + –––––––––– ( T" - T )
T' - T
(19) )
Where C = correction in degree centigrade,
N = number of intervals over which correction is made,
R = initial radiation in degrees per interval,
R' = final radiation in degrees per interval,
T = average temperature for period through which initial radiation is computed,
T" = average temperature over period of combustion[39],
T' = average temperature over period through which final radiation is computed.[39]
The application of this formula to Fig. 25 is as follows:
As already stated, the temperature at the beginning of combustion is the reading just
before the current is turned on, or B in Fig. 25. The point C or the temperature at which
combustion is presumably completed, should be taken at a point which falls well within
the established final rate of radiation, and not at the maximum temperature that the
thermometer indicates in the test, unless it lies on the straight line determining the final
radiation. This is due to the fact that in certain instances local conditions will cause the
thermometer to read higher than it should during the time that the bomb is transmitting
heat to the water rapidly, and at other times the maximum temperature might be lower than
that which would be indicated were readings to be taken at intervals of less than one-half
minute, i. e., the point of maximum temperature will fall below the line determined by the
final rate of radiation. With this understanding AB, Fig. 25, represents the time of initial
radiation, BC the time of [Pg 188] combustion, and CD the time of final radiation. Therefore
to apply Pfaundler’s correction, formula (19), to the data as represented by Fig. 25.
N = 6, R = 0, R' = .01, T = 20.29, T' = 22.83,
T" = 20.29 + 22.54 + 22.84 + 22.88 + 22.87 + 22.86 = 22.36
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
temperatures between the points B and C are proportional to the initial and final rates. That
is, the rate of radiation at a point midway between B and C will be the mean between the
initial and final rates; the rate of radiation at a point three-quarters of the distance between
B and C would be the rate at B plus three-quarters of the difference in rates at B and C, etc.
This method differs from Regnault’s in that the radiation was assumed by Regnault to be
in each case proportional to the difference in temperatures between the water of the
calorimeter and the surrounding air plus a constant found for each experiment. Pfaundler’s
method is more simple than that of Regnault, and the results by the two methods are in
practical agreement.
Expressed as a formula, Pfaundler’s method is, though not in form given by him:
R' - R
(
C = N R + –––––––––– ( T" - T )
T' - T
(19) )
Where C = correction in degree centigrade,
N = number of intervals over which correction is made,
R = initial radiation in degrees per interval,
R' = final radiation in degrees per interval,
T = average temperature for period through which initial radiation is computed,
T" = average temperature over period of combustion[39],
T' = average temperature over period through which final radiation is computed.[39]
The application of this formula to Fig. 25 is as follows:
As already stated, the temperature at the beginning of combustion is the reading just
before the current is turned on, or B in Fig. 25. The point C or the temperature at which
combustion is presumably completed, should be taken at a point which falls well within
the established final rate of radiation, and not at the maximum temperature that the
thermometer indicates in the test, unless it lies on the straight line determining the final
radiation. This is due to the fact that in certain instances local conditions will cause the
thermometer to read higher than it should during the time that the bomb is transmitting
heat to the water rapidly, and at other times the maximum temperature might be lower than
that which would be indicated were readings to be taken at intervals of less than one-half
minute, i. e., the point of maximum temperature will fall below the line determined by the
final rate of radiation. With this understanding AB, Fig. 25, represents the time of initial
radiation, BC the time of [Pg 188] combustion, and CD the time of final radiation. Therefore
to apply Pfaundler’s correction, formula (19), to the data as represented by Fig. 25.
N = 6, R = 0, R' = .01, T = 20.29, T' = 22.83,
T" = 20.29 + 22.54 + 22.84 + 22.88 + 22.87 + 22.86 = 22.36
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Page 259
6
.01 - 0
C=6 0+ ( –––––––––––––––––––––
22.85 - 20.29
( 22.36 - 20.29 ) )
= 6 × .008 = .048
Pfaundler’s formula while simple is rather long. Mr. E. H. Peabody has devised a simpler
formula with which, under proper conditions, the variation from correction as found by
Pfaundler’s method is negligible.
It was noted throughout an extended series of calorimeter tests that the maximum
temperature was reached by the thermometer slightly over one minute after the time of
firing. If this period between the time of firing and the maximum temperature reported
was exactly one minute, the radiation through this period would equal the radiation per
one-half minute before firing plus the radiation per one-half minute after the maximum
temperature is reached; or, the radiation through the one minute interval would be the
average of the radiation per minute before firing and the radiation per minute after the
maximum. A plotted chart of temperatures would take the form of a curve of three straight
lines (B, C', D) in Fig. 25. Under such conditions, using the notation as in formula (19) the
correction would become,
2R + 2R'
C = ––––––––––––––– + ( N - 2 ) R', or R + (N - 1)R' (20)
2
This formula may be generalized for conditions where the maximum temperature is
reached after a period of more than one minute as follows:
Let M = the number of intervals between the time of firing and the maximum temperature.
Then the radiation through this period will be an average of the radiation for M intervals
before firing and for M intervals after the maximum is recorded, or
MR + MR' M M
C= ––––––––––––––––– + ( N - M ) R' = –––– R + ( N - –––– ) R' (21)
2 2 2
In the case of Mr. Peabody’s deductions M was found to be approximately 2 and formula
(21) becomes directly, C = R + (N - 1)R' or formula (20).
The corrections to be made, as secured by the use of this formula, are very close to those
secured by Pfaundler’s method, where the point of maximum temperature is not more than
five intervals later than the point of firing. Where a longer period than this is indicated in
the chart of plotted temperatures, the approximate formula should not be used. As the
period between firing and the maximum temperature is increased, the plotted results are
.01 - 0
C=6 0+ ( –––––––––––––––––––––
22.85 - 20.29
( 22.36 - 20.29 ) )
= 6 × .008 = .048
Pfaundler’s formula while simple is rather long. Mr. E. H. Peabody has devised a simpler
formula with which, under proper conditions, the variation from correction as found by
Pfaundler’s method is negligible.
It was noted throughout an extended series of calorimeter tests that the maximum
temperature was reached by the thermometer slightly over one minute after the time of
firing. If this period between the time of firing and the maximum temperature reported
was exactly one minute, the radiation through this period would equal the radiation per
one-half minute before firing plus the radiation per one-half minute after the maximum
temperature is reached; or, the radiation through the one minute interval would be the
average of the radiation per minute before firing and the radiation per minute after the
maximum. A plotted chart of temperatures would take the form of a curve of three straight
lines (B, C', D) in Fig. 25. Under such conditions, using the notation as in formula (19) the
correction would become,
2R + 2R'
C = ––––––––––––––– + ( N - 2 ) R', or R + (N - 1)R' (20)
2
This formula may be generalized for conditions where the maximum temperature is
reached after a period of more than one minute as follows:
Let M = the number of intervals between the time of firing and the maximum temperature.
Then the radiation through this period will be an average of the radiation for M intervals
before firing and for M intervals after the maximum is recorded, or
MR + MR' M M
C= ––––––––––––––––– + ( N - M ) R' = –––– R + ( N - –––– ) R' (21)
2 2 2
In the case of Mr. Peabody’s deductions M was found to be approximately 2 and formula
(21) becomes directly, C = R + (N - 1)R' or formula (20).
The corrections to be made, as secured by the use of this formula, are very close to those
secured by Pfaundler’s method, where the point of maximum temperature is not more than
five intervals later than the point of firing. Where a longer period than this is indicated in
the chart of plotted temperatures, the approximate formula should not be used. As the
period between firing and the maximum temperature is increased, the plotted results are
Page 260
further and further away from the theoretical straight line curve. Where this period is not
over five intervals, or two and a half minutes, an approximation of the straight line curve
may be plotted by eye, and ordinarily the radiation correction to be applied may be
determined very closely from such an approximated curve.
Peabody’s approximate formula has been found from a number of tests to give results
within .003 degrees Fahrenheit for the limits within which its application holds [Pg 189]
good as described. The value of M, which is not necessarily a whole number, should be
determined for each test, though in all probability such a value is a constant for any
individual calorimeter which is properly operated.
The correction for radiation as found on page 188 is in all instances to be added to the
range of temperature between the firing point and the point chosen from which the final
radiation is calculated. This corrected range multiplied by the water equivalent of the
calorimeter gives the heat of combustion in calories of the coal burned in the calorimeter
together with that evolved by the burning of the fuse wire. The heat evolved by the
burning of the fuse wire is found from the determination of the actual weight of wire
burned and the heat of combustion of one milligram of the wire (1.7 calories), i. e.,
multiply the weight of wire used by 1.7, the result being in gram calories or the heat
required to raise one gram of water one degree centigrade.
Other small corrections to be made are those for the formation of nitric acid and for the
combustion of sulphur to sulphuric acid instead of sulphur dioxide, due to the more
complete combustion in the presence of oxygen than would be possible in the atmosphere.
To make these corrections the bomb of the calorimeter is carefully washed out with water
after each test and the amount of acid determined from titrating this water with a standard
solution of ammonia or of caustic soda, all of the acid being assumed to be nitric acid.
Each cubic centimeter of the ammonia titrating solution used is equivalent to a correction
of 2.65 calories.
As part of acidity is due to the formation of sulphuric acid, a further correction is
necessary. In burning sulphuric acid the heat evolved per gram of sulphur is 2230 calories
in excess of the heat which would be evolved if the sulphur burned to sulphur dioxide, or
22.3 calories for each per cent of sulphur in the coal. One cubic centimeter of the ammonia
solution is equivalent to 0.00286 grams of sulphur as sulphuric acid, or to 0.286 × 22.3 =
6.38 calories. It is evident therefore that after multiplying the number of cubic centimeters
used in titrating by the heat factor for nitric acid (2.65) a further correction of 6.38 - 2.65 =
3.73 is necessary for each cubic centimeter used in titrating sulphuric instead of nitric acid.
This correction will be 3.73⁄0.297 = 13 units for each 0.01 gram of sulphur in the coal.
The total correction therefore for the aqueous nitric and sulphuric acid is found by
multiplying the ammonia by 2.65 and adding 13 calories for each 0.01 gram of sulphur in
the coal. This total correction is to be deducted from the heat value as found from the
corrected range and the amount equivalent to the calorimeter.
over five intervals, or two and a half minutes, an approximation of the straight line curve
may be plotted by eye, and ordinarily the radiation correction to be applied may be
determined very closely from such an approximated curve.
Peabody’s approximate formula has been found from a number of tests to give results
within .003 degrees Fahrenheit for the limits within which its application holds [Pg 189]
good as described. The value of M, which is not necessarily a whole number, should be
determined for each test, though in all probability such a value is a constant for any
individual calorimeter which is properly operated.
The correction for radiation as found on page 188 is in all instances to be added to the
range of temperature between the firing point and the point chosen from which the final
radiation is calculated. This corrected range multiplied by the water equivalent of the
calorimeter gives the heat of combustion in calories of the coal burned in the calorimeter
together with that evolved by the burning of the fuse wire. The heat evolved by the
burning of the fuse wire is found from the determination of the actual weight of wire
burned and the heat of combustion of one milligram of the wire (1.7 calories), i. e.,
multiply the weight of wire used by 1.7, the result being in gram calories or the heat
required to raise one gram of water one degree centigrade.
Other small corrections to be made are those for the formation of nitric acid and for the
combustion of sulphur to sulphuric acid instead of sulphur dioxide, due to the more
complete combustion in the presence of oxygen than would be possible in the atmosphere.
To make these corrections the bomb of the calorimeter is carefully washed out with water
after each test and the amount of acid determined from titrating this water with a standard
solution of ammonia or of caustic soda, all of the acid being assumed to be nitric acid.
Each cubic centimeter of the ammonia titrating solution used is equivalent to a correction
of 2.65 calories.
As part of acidity is due to the formation of sulphuric acid, a further correction is
necessary. In burning sulphuric acid the heat evolved per gram of sulphur is 2230 calories
in excess of the heat which would be evolved if the sulphur burned to sulphur dioxide, or
22.3 calories for each per cent of sulphur in the coal. One cubic centimeter of the ammonia
solution is equivalent to 0.00286 grams of sulphur as sulphuric acid, or to 0.286 × 22.3 =
6.38 calories. It is evident therefore that after multiplying the number of cubic centimeters
used in titrating by the heat factor for nitric acid (2.65) a further correction of 6.38 - 2.65 =
3.73 is necessary for each cubic centimeter used in titrating sulphuric instead of nitric acid.
This correction will be 3.73⁄0.297 = 13 units for each 0.01 gram of sulphur in the coal.
The total correction therefore for the aqueous nitric and sulphuric acid is found by
multiplying the ammonia by 2.65 and adding 13 calories for each 0.01 gram of sulphur in
the coal. This total correction is to be deducted from the heat value as found from the
corrected range and the amount equivalent to the calorimeter.
Page 261
After each test the pan in which the coal has been burned must be carefully examined to
make sure that all of the sample has undergone complete combustion. The presence of
black specks ordinarily indicates unburned coal, and often will be found where the coal
contains bone or slate. Where such specks are found the tests should be repeated. In
testing any fuel where it is found difficult to completely consume a sample, a weighed
amount of naphthaline may be added, the total weight of fuel and naphthaline being
approximately one gram. The naphthaline has a known heat of combustion, samples for
this purpose being obtainable from the United States Bureau of Standards, and from the
combined heat of combustion of the fuel and naphthaline that of the former may be readily
computed.
The heat evolved in burning of a definite weight of standard naphthaline may also be used
as a means of calibrating the calorimeter as a whole.
FOOTNOTES
[36] See page 161.
[37] U. S. Geological Survey.
[38] See “Steam Boiler Economy”, page 47, First Edition.
[39] To agree with Pfaundler’s formula the end ordinates should be given half values in
determining T", i. e., T" = ((Temp. at B + Temp. at C) ÷ 2 + Temp. all other ordinates) ÷ N
make sure that all of the sample has undergone complete combustion. The presence of
black specks ordinarily indicates unburned coal, and often will be found where the coal
contains bone or slate. Where such specks are found the tests should be repeated. In
testing any fuel where it is found difficult to completely consume a sample, a weighed
amount of naphthaline may be added, the total weight of fuel and naphthaline being
approximately one gram. The naphthaline has a known heat of combustion, samples for
this purpose being obtainable from the United States Bureau of Standards, and from the
combined heat of combustion of the fuel and naphthaline that of the former may be readily
computed.
The heat evolved in burning of a definite weight of standard naphthaline may also be used
as a means of calibrating the calorimeter as a whole.
FOOTNOTES
[36] See page 161.
[37] U. S. Geological Survey.
[38] See “Steam Boiler Economy”, page 47, First Edition.
[39] To agree with Pfaundler’s formula the end ordinates should be given half values in
determining T", i. e., T" = ((Temp. at B + Temp. at C) ÷ 2 + Temp. all other ordinates) ÷ N
Page 262
[Pg 190]
Page 263
COMBUSTION OF COAL
The composition of coal varies over such a wide range, and the methods of
firing have to be altered so greatly to suit the various coals and the
innumerable types of furnaces in which they are burned, that any instructions
given for the handling of different fuels must of necessity be of the most
general character. For each kind of coal there is some method of firing which
will give the best results for each individual set of conditions. General rules
can be suggested, but the best results can be obtained only by following such
methods as experience and practice show to be the best suited to the specific
conditions.
The question of draft is an all important factor. If this be insufficient, proper
combustion is impossible, as the suction in the furnace will not be great
enough to draw the necessary amount of air through the fuel bed, and the
gases may pass off only partially consumed. On the other hand, an excessive
draft may cause losses due to the excess quantities of air drawn through
holes in the fire. Where coal is burned however, there are rarely complaints
from excessive draft, as this can be and should be regulated by the boiler
damper to give only the draft necessary for the particular rate of combustion
desired. The draft required for various kinds of fuel is treated in detail in the
chapter on “Chimneys and Draft”. In this chapter it will be assumed that the
draft is at all times ample and that it is regulated to give the best results for
each kind of coal.
TABLE 40 Anthra
cite—
ANTHRACITE COAL SIZES Anthrac
Testing Segments ite coal
Round Mesh Standard Square is
Trade Name Mesh ordinaril
Through Over Through Over y
Inches Inches Inches Inches markete
d under
Broken 41⁄2 31⁄4 4 23⁄4
the
The composition of coal varies over such a wide range, and the methods of
firing have to be altered so greatly to suit the various coals and the
innumerable types of furnaces in which they are burned, that any instructions
given for the handling of different fuels must of necessity be of the most
general character. For each kind of coal there is some method of firing which
will give the best results for each individual set of conditions. General rules
can be suggested, but the best results can be obtained only by following such
methods as experience and practice show to be the best suited to the specific
conditions.
The question of draft is an all important factor. If this be insufficient, proper
combustion is impossible, as the suction in the furnace will not be great
enough to draw the necessary amount of air through the fuel bed, and the
gases may pass off only partially consumed. On the other hand, an excessive
draft may cause losses due to the excess quantities of air drawn through
holes in the fire. Where coal is burned however, there are rarely complaints
from excessive draft, as this can be and should be regulated by the boiler
damper to give only the draft necessary for the particular rate of combustion
desired. The draft required for various kinds of fuel is treated in detail in the
chapter on “Chimneys and Draft”. In this chapter it will be assumed that the
draft is at all times ample and that it is regulated to give the best results for
each kind of coal.
TABLE 40 Anthra
cite—
ANTHRACITE COAL SIZES Anthrac
Testing Segments ite coal
Round Mesh Standard Square is
Trade Name Mesh ordinaril
Through Over Through Over y
Inches Inches Inches Inches markete
d under
Broken 41⁄2 31⁄4 4 23⁄4
the
Page 264
Egg 31⁄4 23⁄8 23⁄4 2 names
Stove 23⁄8 15⁄8 2 13⁄8 and
Chestnut 15⁄8 7⁄8 13⁄8 3⁄4 sizes
Pea 7⁄8 5⁄8 3⁄4 1⁄2 given in
No. 1 Buckwheat 5⁄8 3⁄8 1⁄2 1⁄4
Table
40.
No. 2 Buckwheat or Rice 3⁄8 3⁄16 1⁄4 1⁄8
No. 3 Buckwheat or Barley 3⁄16 3⁄32 1⁄8 1⁄16 The
larger
sizes of anthracite are rarely used for commercial steam generating purposes
as the demand for domestic use now limits the supply. In commercial plants
the sizes generally found are Nos. 1, 2 and 3 buckwheat. In some plants
where the finer sizes are used, a small percentage of bituminous coal, say, 10
per cent, is sometimes mixed with the anthracite and beneficial results
secured both in economy and capacity.
Anthracite coal should be fired evenly, in small quantities and at frequent
intervals. If this method is not followed, dead spots will appear in the fire,
and if the fire gets too irregular through burning in patches, nothing can be
done to remedy it until the fire is cleaned as a whole. After this grade of fuel
has been fired it should be left alone, and the fire tools used as little as
possible. Owing to the difficulty of igniting this fuel, care must be taken in
cleaning fires. The intervals of cleaning will, of course, depend upon the
nature of the coal and the rate of combustion. With the small sizes and
moderately high combustion rates, fires will have to be cleaned twice [Pg 191]
on each eight-hour shift. As the fires become dirty the thickness of the fuel
bed will increase, until this depth may be 12 or 14 inches just before a
cleaning period. In cleaning, the following practice is usually followed: The
good coal on the forward half of the grate is pushed to the rear half, and the
refuse on the front portion either pulled out or dumped. The good coal is
then pulled forward onto the front part of the grate and the refuse on the rear
section dumped. The remaining good coal is then spread evenly over the
whole grate surface and the fire built up with fresh coal.
A ratio of grate surface to heating surface of 1 to from 35 to 40 will under
ordinary conditions develop the rated capacity of a boiler when burning
anthracite buckwheat. Where the finer sizes are used, or where overloads are
desirable, however, this ratio should preferably be 1 to 25 and a forced blast
Stove 23⁄8 15⁄8 2 13⁄8 and
Chestnut 15⁄8 7⁄8 13⁄8 3⁄4 sizes
Pea 7⁄8 5⁄8 3⁄4 1⁄2 given in
No. 1 Buckwheat 5⁄8 3⁄8 1⁄2 1⁄4
Table
40.
No. 2 Buckwheat or Rice 3⁄8 3⁄16 1⁄4 1⁄8
No. 3 Buckwheat or Barley 3⁄16 3⁄32 1⁄8 1⁄16 The
larger
sizes of anthracite are rarely used for commercial steam generating purposes
as the demand for domestic use now limits the supply. In commercial plants
the sizes generally found are Nos. 1, 2 and 3 buckwheat. In some plants
where the finer sizes are used, a small percentage of bituminous coal, say, 10
per cent, is sometimes mixed with the anthracite and beneficial results
secured both in economy and capacity.
Anthracite coal should be fired evenly, in small quantities and at frequent
intervals. If this method is not followed, dead spots will appear in the fire,
and if the fire gets too irregular through burning in patches, nothing can be
done to remedy it until the fire is cleaned as a whole. After this grade of fuel
has been fired it should be left alone, and the fire tools used as little as
possible. Owing to the difficulty of igniting this fuel, care must be taken in
cleaning fires. The intervals of cleaning will, of course, depend upon the
nature of the coal and the rate of combustion. With the small sizes and
moderately high combustion rates, fires will have to be cleaned twice [Pg 191]
on each eight-hour shift. As the fires become dirty the thickness of the fuel
bed will increase, until this depth may be 12 or 14 inches just before a
cleaning period. In cleaning, the following practice is usually followed: The
good coal on the forward half of the grate is pushed to the rear half, and the
refuse on the front portion either pulled out or dumped. The good coal is
then pulled forward onto the front part of the grate and the refuse on the rear
section dumped. The remaining good coal is then spread evenly over the
whole grate surface and the fire built up with fresh coal.
A ratio of grate surface to heating surface of 1 to from 35 to 40 will under
ordinary conditions develop the rated capacity of a boiler when burning
anthracite buckwheat. Where the finer sizes are used, or where overloads are
desirable, however, this ratio should preferably be 1 to 25 and a forced blast
Page 265
should be used. Grates 10 feet deep with a slope of 1½ inches to the foot can
be handled comfortably with this class of fuel, and grates 12 feet deep with
the same slope can be successfully handled. Where grates over 8 feet in
depth are necessary, shaking grates or overlapping dumping grates should be
used. Dumping grates may be applied either for the whole grate surface or to
the rear section. Air openings in the grate bars should be made from 3⁄16 inch
in width for No. 3 buckwheat to 5⁄16 inch for No. 1 buckwheat. It is
important that these air openings be uniformly distributed over the whole
surface to avoid blowing holes in the fire, and it is for this reason that
overlapping grates are recommended.
No air should be admitted over the fire. Steam is sometimes introduced into
the ashpit to soften any clinker that may form, but the quantity of steam
should be limited to that required for this purpose. The steam that may be
used in a steam jet blower for securing blast will in certain instances assist in
softening the clinker, but a much greater quantity may be used by such an
apparatus than is required for this purpose. Combustion arches sprung above
the grates have proved of advantage in maintaining a high furnace
temperature and in assisting in the ignition of fresh coal.
Stacks used with forced blast should be of such size as to insure a slight
suction in the furnace under any conditions of operation. A blast up to 3
inches of water should be available for the finer sizes supplied by engine
driven fans, automatically controlled by the boiler pressure. The blast
required will increase as the depth of the fuel bed increases, and the slight
suction should be maintained in the furnace by damper regulation.
The use of blast with the finer sizes causes rapid fouling of the heating
surfaces of the boiler, the dust often amounting to over 10 per cent of the
total fuel fired. Economical disposal of dust and ashes is of the utmost
importance in burning fuel of this nature. Provision should be made in the
baffling of the boiler to accommodate and dispose of this dust. Whenever
conditions permit, the ashes can be economically disposed of by flushing
them out with water.
Bituminous Coals—There is no classification of bituminous coal as to size
that holds good in all localities. The American Society of Mechanical
Engineers suggests the following grading:
be handled comfortably with this class of fuel, and grates 12 feet deep with
the same slope can be successfully handled. Where grates over 8 feet in
depth are necessary, shaking grates or overlapping dumping grates should be
used. Dumping grates may be applied either for the whole grate surface or to
the rear section. Air openings in the grate bars should be made from 3⁄16 inch
in width for No. 3 buckwheat to 5⁄16 inch for No. 1 buckwheat. It is
important that these air openings be uniformly distributed over the whole
surface to avoid blowing holes in the fire, and it is for this reason that
overlapping grates are recommended.
No air should be admitted over the fire. Steam is sometimes introduced into
the ashpit to soften any clinker that may form, but the quantity of steam
should be limited to that required for this purpose. The steam that may be
used in a steam jet blower for securing blast will in certain instances assist in
softening the clinker, but a much greater quantity may be used by such an
apparatus than is required for this purpose. Combustion arches sprung above
the grates have proved of advantage in maintaining a high furnace
temperature and in assisting in the ignition of fresh coal.
Stacks used with forced blast should be of such size as to insure a slight
suction in the furnace under any conditions of operation. A blast up to 3
inches of water should be available for the finer sizes supplied by engine
driven fans, automatically controlled by the boiler pressure. The blast
required will increase as the depth of the fuel bed increases, and the slight
suction should be maintained in the furnace by damper regulation.
The use of blast with the finer sizes causes rapid fouling of the heating
surfaces of the boiler, the dust often amounting to over 10 per cent of the
total fuel fired. Economical disposal of dust and ashes is of the utmost
importance in burning fuel of this nature. Provision should be made in the
baffling of the boiler to accommodate and dispose of this dust. Whenever
conditions permit, the ashes can be economically disposed of by flushing
them out with water.
Bituminous Coals—There is no classification of bituminous coal as to size
that holds good in all localities. The American Society of Mechanical
Engineers suggests the following grading:
Page 266
Eastern Bituminous Coals—
(A) Run of mine coal; the unscreened coal taken from the mine.
(B) Lump coal; that which passes over a bar-screen with openings 1¼
inches wide.
(C) Nut coal; that which passes through a bar-screen with 1¼-inch
[Pg 192] openings and over one with ¾-inch openings.
(D) Slack coal; that which passes through a bar-screen with ¾-inch
openings.
Western Bituminous Coals—
(E) Run of mine coal; the unscreened coal taken from the mine.
(F) Lump coal; divided into 6-inch, 3-inch and 1¼-inch lump,
according to the diameter of the circular openings over which the
respective grades pass; also 6 × 3-inch lump and 3 × 1¼-inch
lump, according as the coal passes through a circular opening
having the diameter of the larger figure and over that of the
smaller diameter.
(G) Nut coal; divided into 3-inch steam nut, which passes through an
opening 3 inches diameter and over 1¼ inches; 1¼ inch nut,
which passes through a 1¼-inch diameter opening and over a ¾-
inch diameter opening; ¾-inch nut, which passes through a ¾-
inch diameter opening and over a 5⁄8-inch diameter opening.
(H) Screenings; that which passes through a 1¼-inch diameter
opening.
As the variation in character of bituminous coals is much greater than in the
anthracites, any rules set down for their handling must be the more general.
The difficulties in burning bituminous coals with economy and with little or
no smoke increases as the content of fixed carbon in the coal decreases. It is
their volatile content which causes the difficulties and it is essential that the
furnaces be designed to properly handle this portion of the coal. The fixed
carbon will take care of itself, provided the volatile matter is properly
burned.
Mr. Kent, in his “Steam Boiler Economy”, described the action of
bituminous coal after it is fired as follows: “The first thing that the fine fresh
coal does is to choke the air spaces existing through the bed of coke, thus
(A) Run of mine coal; the unscreened coal taken from the mine.
(B) Lump coal; that which passes over a bar-screen with openings 1¼
inches wide.
(C) Nut coal; that which passes through a bar-screen with 1¼-inch
[Pg 192] openings and over one with ¾-inch openings.
(D) Slack coal; that which passes through a bar-screen with ¾-inch
openings.
Western Bituminous Coals—
(E) Run of mine coal; the unscreened coal taken from the mine.
(F) Lump coal; divided into 6-inch, 3-inch and 1¼-inch lump,
according to the diameter of the circular openings over which the
respective grades pass; also 6 × 3-inch lump and 3 × 1¼-inch
lump, according as the coal passes through a circular opening
having the diameter of the larger figure and over that of the
smaller diameter.
(G) Nut coal; divided into 3-inch steam nut, which passes through an
opening 3 inches diameter and over 1¼ inches; 1¼ inch nut,
which passes through a 1¼-inch diameter opening and over a ¾-
inch diameter opening; ¾-inch nut, which passes through a ¾-
inch diameter opening and over a 5⁄8-inch diameter opening.
(H) Screenings; that which passes through a 1¼-inch diameter
opening.
As the variation in character of bituminous coals is much greater than in the
anthracites, any rules set down for their handling must be the more general.
The difficulties in burning bituminous coals with economy and with little or
no smoke increases as the content of fixed carbon in the coal decreases. It is
their volatile content which causes the difficulties and it is essential that the
furnaces be designed to properly handle this portion of the coal. The fixed
carbon will take care of itself, provided the volatile matter is properly
burned.
Mr. Kent, in his “Steam Boiler Economy”, described the action of
bituminous coal after it is fired as follows: “The first thing that the fine fresh
coal does is to choke the air spaces existing through the bed of coke, thus
Page 267
shutting off the air supply which is needed to burn the gases produced from
the fresh coal. The next thing is a very rapid evaporation of moisture from
the coal, a chilling process, which robs the furnace of heat. Next is the
formation of water-gas by the chemical reaction, C + H2O = CO + 2H, the
steam being decomposed, its oxygen burning the carbon of the coal to
carbonic oxide, and the hydrogen being liberated. This reaction takes place
when steam is brought in contact with highly heated carbon. This also is a
chilling process, absorbing heat from the furnaces. The two valuable fuel
gases thus generated would give back all the heat absorbed in their formation
if they could be burned, but there is not enough air in the furnace to burn
them. Admitting extra air through the fire door at this time will be of no
service, for the gases being comparatively cool cannot be burned unless the
air is highly heated. After all the moisture has been driven off from the coal,
the distillation of hydrocarbons begins, and a considerable portion of them
escapes unburned, owing to the deficiency of hot air, and to their being
chilled by the relatively cool heating surfaces of the boiler. During all this
time great volumes of smoke are escaping from the chimney, together with
unburned hydrogen, hydrocarbons, and carbonic oxide, all fuel gases, while
at the same time soot is being deposited on the heating surface, diminishing
its efficiency in transmitting heat to the water.”
[Pg 193]
To burn these gases distilled from the coal, it is necessary that they be
brought into contact with air sufficiently heated to cause them to ignite, that
sufficient space be allowed for their mixture with the air, and that sufficient
time be allowed for their complete combustion before they strike the boiler
heating surfaces, since these surfaces are comparatively cool and will lower
the temperature of the gases below their ignition point. The air drawn
through the fire by the draft suction is heated in its passage and heat is added
by radiation from the hot brick surfaces of the furnace, the air and volatile
gases mixing as this increase in temperature is taking place. Thus in most
instances is the first requirement fulfilled. The element of space for the
proper mixture of the gases with the air, and of time in which combustion is
to take place, should be taken care of by sufficiently large combustion
chambers.
the fresh coal. The next thing is a very rapid evaporation of moisture from
the coal, a chilling process, which robs the furnace of heat. Next is the
formation of water-gas by the chemical reaction, C + H2O = CO + 2H, the
steam being decomposed, its oxygen burning the carbon of the coal to
carbonic oxide, and the hydrogen being liberated. This reaction takes place
when steam is brought in contact with highly heated carbon. This also is a
chilling process, absorbing heat from the furnaces. The two valuable fuel
gases thus generated would give back all the heat absorbed in their formation
if they could be burned, but there is not enough air in the furnace to burn
them. Admitting extra air through the fire door at this time will be of no
service, for the gases being comparatively cool cannot be burned unless the
air is highly heated. After all the moisture has been driven off from the coal,
the distillation of hydrocarbons begins, and a considerable portion of them
escapes unburned, owing to the deficiency of hot air, and to their being
chilled by the relatively cool heating surfaces of the boiler. During all this
time great volumes of smoke are escaping from the chimney, together with
unburned hydrogen, hydrocarbons, and carbonic oxide, all fuel gases, while
at the same time soot is being deposited on the heating surface, diminishing
its efficiency in transmitting heat to the water.”
[Pg 193]
To burn these gases distilled from the coal, it is necessary that they be
brought into contact with air sufficiently heated to cause them to ignite, that
sufficient space be allowed for their mixture with the air, and that sufficient
time be allowed for their complete combustion before they strike the boiler
heating surfaces, since these surfaces are comparatively cool and will lower
the temperature of the gases below their ignition point. The air drawn
through the fire by the draft suction is heated in its passage and heat is added
by radiation from the hot brick surfaces of the furnace, the air and volatile
gases mixing as this increase in temperature is taking place. Thus in most
instances is the first requirement fulfilled. The element of space for the
proper mixture of the gases with the air, and of time in which combustion is
to take place, should be taken care of by sufficiently large combustion
chambers.
Page 268
Certain bituminous coals, owing to their high volatile content, require that
the air be heated to a higher temperature than it is possible for it to attain
simply in its passage through the fire and by absorption from the side walls
of the furnace. Such coals can be burned with the best results under fire
brick arches. Such arches increase the temperature of the furnace and in this
way maintain the heat that must be present for ignition and complete
combustion of the fuels in question. These fuels too, sometimes require
additional combustion space, and an extension furnace will give this in
addition to the required arches.
As stated, the difficulty of burning bituminous coals successfully will
increase with the increase in volatile matter. This percentage of volatile will
affect directly the depth of coal bed to be carried and the intervals of firing
for the most satisfactory results. The variation in the fuel over such wide
ranges makes it impossible to definitely state the thickness of fires for all
classes, and experiment with the class of fuel in use is the best method of
determining how that particular fuel should be handled. The following
suggestions, which are not to be considered in any sense hard and fast rules,
may be of service for general operating conditions for hand firing:
Semi-bituminous coals, such as Pocahontas, New River, Clearfield, etc.,
require fires from 10 to 14 inches thick; fresh coal should be fired at
intervals of 10 to 20 minutes and sufficient coal charged at each firing to
maintain a uniform thickness. Bituminous coals from Pittsburgh Region
require fires from 4 to 6 inches thick, and should be fired often in
comparatively small charges. Kentucky, Tennessee, Ohio and Illinois coals
require a thickness from 4 to 6 inches. Free burning coals from Rock
Springs, Wyoming, require from 6 to 8 inches, while the poorer grades of
Montana, Utah and Washington bituminous coals require a depth of about 4
inches.
In general as thin fires are found necessary, the intervals of firing should be
made more frequent and the quantity of coal fired at each interval smaller.
As thin fires become necessary due to the character of the coal, the tendency
to clinker will increase if the thickness be increased over that found to give
the best results.
the air be heated to a higher temperature than it is possible for it to attain
simply in its passage through the fire and by absorption from the side walls
of the furnace. Such coals can be burned with the best results under fire
brick arches. Such arches increase the temperature of the furnace and in this
way maintain the heat that must be present for ignition and complete
combustion of the fuels in question. These fuels too, sometimes require
additional combustion space, and an extension furnace will give this in
addition to the required arches.
As stated, the difficulty of burning bituminous coals successfully will
increase with the increase in volatile matter. This percentage of volatile will
affect directly the depth of coal bed to be carried and the intervals of firing
for the most satisfactory results. The variation in the fuel over such wide
ranges makes it impossible to definitely state the thickness of fires for all
classes, and experiment with the class of fuel in use is the best method of
determining how that particular fuel should be handled. The following
suggestions, which are not to be considered in any sense hard and fast rules,
may be of service for general operating conditions for hand firing:
Semi-bituminous coals, such as Pocahontas, New River, Clearfield, etc.,
require fires from 10 to 14 inches thick; fresh coal should be fired at
intervals of 10 to 20 minutes and sufficient coal charged at each firing to
maintain a uniform thickness. Bituminous coals from Pittsburgh Region
require fires from 4 to 6 inches thick, and should be fired often in
comparatively small charges. Kentucky, Tennessee, Ohio and Illinois coals
require a thickness from 4 to 6 inches. Free burning coals from Rock
Springs, Wyoming, require from 6 to 8 inches, while the poorer grades of
Montana, Utah and Washington bituminous coals require a depth of about 4
inches.
In general as thin fires are found necessary, the intervals of firing should be
made more frequent and the quantity of coal fired at each interval smaller.
As thin fires become necessary due to the character of the coal, the tendency
to clinker will increase if the thickness be increased over that found to give
the best results.
Page 269
There are two general methods of hand firing: 1st, the spreading method;
and 2nd, the coking method.
In the spreading method but little fuel is fired at one time, and is spread
evenly over the fuel bed from front to rear. Where there is more than one
firing door the doors should be fired alternately. The advantage of alternate
firing is the whole surface of the fire is not blanketed with green coal, and
steam is generated more uniformly than if all doors were fired at one time.
Again, a better combustion results [Pg 194]
[Pg 195] due to the burning of more of the volatile matter directly after firing
than where all doors are fired at one time.
Babcock & Wilcox Chain Grate Stoker
In the coking method, fresh coal is fired at considerable depth at the front of
the grate and after it is partially coked it is pushed back into the furnace. The
object of such a method is the preserving of a bed of carbon at the rear of the
grate, in passing over which the volatile gases driven off from the green coal
and 2nd, the coking method.
In the spreading method but little fuel is fired at one time, and is spread
evenly over the fuel bed from front to rear. Where there is more than one
firing door the doors should be fired alternately. The advantage of alternate
firing is the whole surface of the fire is not blanketed with green coal, and
steam is generated more uniformly than if all doors were fired at one time.
Again, a better combustion results [Pg 194]
[Pg 195] due to the burning of more of the volatile matter directly after firing
than where all doors are fired at one time.
Babcock & Wilcox Chain Grate Stoker
In the coking method, fresh coal is fired at considerable depth at the front of
the grate and after it is partially coked it is pushed back into the furnace. The
object of such a method is the preserving of a bed of carbon at the rear of the
grate, in passing over which the volatile gases driven off from the green coal
Page 270
will be burned. This method is particularly adaptable to a grate in which the
gases are made to pass horizontally over the fire. Modern practice for hand
firing leans more and more toward the spread firing method. Again the
tendency is to work bituminous coal fires less than formerly. A certain
amount of slicing and raking may be necessary with either method of firing,
but in general, the less the fire is worked the better the results.
Lignites—As the content of volatile matter and moisture in lignite is higher
than in bituminous coal, the difficulties encountered in burning them are
greater. A large combustion space is required and the best results are
obtained where a furnace of the reverberatory type is used, giving the gases a
long travel before meeting the tube surfaces. A fuel bed from 4 to 6 inches in
depth can be maintained, and the coal should be fired in small quantities by
the alternate method. Above certain rates of combustion clinker forms
rapidly, and a steam jet in the ashpit for softening this clinker is often
desirable. A considerable draft should be available, but it should be carefully
regulated by the boiler damper to suit the condition of the fire.
Smokelessness with hand firing with this class of fuel is a practical
impossibility. It has a strong tendency to foul the heating surfaces rapidly
and these surfaces should be cleaned frequently. Shaking grates, intelligently
handled, aid in cleaning the fires, but their manipulation must be carefully
watched to prevent good coal being lost in the ashpit.
Stokers—The term “automatic stoker” oftentimes conveys the erroneous
impression that such an apparatus takes care of itself, and it must be
thoroughly understood that any stoker requires expert attention to as high if
not higher degree than do hand-fired furnaces.
Stoker-fired furnaces have many advantages over hand firing, but where a
stoker installation is contemplated there are many factors to be considered. It
is true that stokers feed coal to the fire automatically, but if the coal has first
to be fed to the stoker hopper by hand, its automatic advantage is lost. This
is as true of the removal of ash from a stoker. In a general way, it may be
stated that a stoker installation is not advantageous except possibly for
diminishing smoke, unless the automatic feature is carried to the handling of
the coal and ash, as where coal and ash handling apparatus is not installed
there is no saving in labor. In large plants, however, stokers used in
conjunction with the modern methods of coal storage and coal and ash
gases are made to pass horizontally over the fire. Modern practice for hand
firing leans more and more toward the spread firing method. Again the
tendency is to work bituminous coal fires less than formerly. A certain
amount of slicing and raking may be necessary with either method of firing,
but in general, the less the fire is worked the better the results.
Lignites—As the content of volatile matter and moisture in lignite is higher
than in bituminous coal, the difficulties encountered in burning them are
greater. A large combustion space is required and the best results are
obtained where a furnace of the reverberatory type is used, giving the gases a
long travel before meeting the tube surfaces. A fuel bed from 4 to 6 inches in
depth can be maintained, and the coal should be fired in small quantities by
the alternate method. Above certain rates of combustion clinker forms
rapidly, and a steam jet in the ashpit for softening this clinker is often
desirable. A considerable draft should be available, but it should be carefully
regulated by the boiler damper to suit the condition of the fire.
Smokelessness with hand firing with this class of fuel is a practical
impossibility. It has a strong tendency to foul the heating surfaces rapidly
and these surfaces should be cleaned frequently. Shaking grates, intelligently
handled, aid in cleaning the fires, but their manipulation must be carefully
watched to prevent good coal being lost in the ashpit.
Stokers—The term “automatic stoker” oftentimes conveys the erroneous
impression that such an apparatus takes care of itself, and it must be
thoroughly understood that any stoker requires expert attention to as high if
not higher degree than do hand-fired furnaces.
Stoker-fired furnaces have many advantages over hand firing, but where a
stoker installation is contemplated there are many factors to be considered. It
is true that stokers feed coal to the fire automatically, but if the coal has first
to be fed to the stoker hopper by hand, its automatic advantage is lost. This
is as true of the removal of ash from a stoker. In a general way, it may be
stated that a stoker installation is not advantageous except possibly for
diminishing smoke, unless the automatic feature is carried to the handling of
the coal and ash, as where coal and ash handling apparatus is not installed
there is no saving in labor. In large plants, however, stokers used in
conjunction with the modern methods of coal storage and coal and ash
Page 271
handling, make possible a large labor saving. In small plants the labor saving
for stokers over hand-fired furnaces is negligible, and the expense of the
installation no less proportionately than in large plants. Stokers are,
therefore, advisable in small plants only where the saving in fuel will be
large, or where the smoke question is important.
Interest on investment, repairs, depreciation and steam required for blast and
stoker drive must all be considered. The upkeep cost will, in general, be
higher than for hand-fired furnaces. Stokers, however, make possible the use
of cheaper fuels with as high or higher economy than is obtainable under
operating conditions in hand-fired furnaces with a better grade of fuel. The
better efficiency obtainable with a [Pg 196] good stoker is due to more even
and continuous firing as against the intermittent firing of hand-fired
furnaces; constant air supply as against a variation in this supply to meet
varying furnace conditions in hand-fired furnaces; and the doing away to a
great extent with the necessity of working the fires.
Stokers under ordinary operating conditions will give more nearly smokeless
combustion than will hand-fired furnaces and for this reason must often be
installed regardless of other considerations. While a constant air supply for a
given power is theoretically secured by the use of a stoker, and in many
instances the draft is automatically governed, the air supply should,
nevertheless, be as carefully watched and checked by flue gas analyses as in
the case of hand-fired furnaces.
There is a tendency in all stokers to cause the loss of some good fuel or
siftings in the ashpit, but suitable arrangements may be made to reclaim this.
In respect to efficiency of combustion, other conditions being equal, there
will be no appreciable difference with the different types of stokers,
provided that the proper type is used for the grade of fuel to be burned and
the conditions of operation to be fulfilled. No stoker will satisfactorily
handle all classes of fuel, and in making a selection, care should be taken
that the type is suited to the fuel and the operating conditions. A cheap stoker
is a poor investment. Only the best stoker suited to the conditions which are
to be met should be adopted, for if there is to be a saving, it will more than
cover the cost of the best over the cheaper stoker.
for stokers over hand-fired furnaces is negligible, and the expense of the
installation no less proportionately than in large plants. Stokers are,
therefore, advisable in small plants only where the saving in fuel will be
large, or where the smoke question is important.
Interest on investment, repairs, depreciation and steam required for blast and
stoker drive must all be considered. The upkeep cost will, in general, be
higher than for hand-fired furnaces. Stokers, however, make possible the use
of cheaper fuels with as high or higher economy than is obtainable under
operating conditions in hand-fired furnaces with a better grade of fuel. The
better efficiency obtainable with a [Pg 196] good stoker is due to more even
and continuous firing as against the intermittent firing of hand-fired
furnaces; constant air supply as against a variation in this supply to meet
varying furnace conditions in hand-fired furnaces; and the doing away to a
great extent with the necessity of working the fires.
Stokers under ordinary operating conditions will give more nearly smokeless
combustion than will hand-fired furnaces and for this reason must often be
installed regardless of other considerations. While a constant air supply for a
given power is theoretically secured by the use of a stoker, and in many
instances the draft is automatically governed, the air supply should,
nevertheless, be as carefully watched and checked by flue gas analyses as in
the case of hand-fired furnaces.
There is a tendency in all stokers to cause the loss of some good fuel or
siftings in the ashpit, but suitable arrangements may be made to reclaim this.
In respect to efficiency of combustion, other conditions being equal, there
will be no appreciable difference with the different types of stokers,
provided that the proper type is used for the grade of fuel to be burned and
the conditions of operation to be fulfilled. No stoker will satisfactorily
handle all classes of fuel, and in making a selection, care should be taken
that the type is suited to the fuel and the operating conditions. A cheap stoker
is a poor investment. Only the best stoker suited to the conditions which are
to be met should be adopted, for if there is to be a saving, it will more than
cover the cost of the best over the cheaper stoker.
Page 272
Mechanical Stokers are of three general types: 1st, overfeed; 2nd,
underfeed; and 3rd, traveling grate. The traveling grate stokers are
sometimes classed as overfeed but properly should be classed by themselves
as under certain conditions they are of the underfeed rather than the overfeed
type.
Overfeed Stokers in general may be divided into two classes, the distinction
being in the direction in which the coal is fed relative to the furnaces. In one
class the coal is fed into hoppers at the front end of the furnace onto grates
with an inclination downward toward the rear of about 45 degrees. These
grates are reciprocated, being made to take alternately level and inclined
positions and this motion gradually carries the fuel as it is burned toward the
rear and bottom of the furnace. At the bottom of the grates flat dumping
sections are supplied for completing the combustion and for cleaning. The
fuel is partly burned or coked on the upper portion of the grates, the volatile
gases driven off in this process for a perfect action being ignited and burned
in their passage over the bed of burning carbon lower on the grates, or on
becoming mixed with the hot gases in the furnace chamber. In the second
class the fuel is fed from the sides of the furnace for its full depth from front
to rear onto grates inclined toward the center of the furnace. It is moved by
rocking bars and is gradually carried to the bottom and center of the furnace
as combustion advances. Here some type of a so-called clinker breaker
removes the refuse.
Underfeed Stokers are either horizontal or inclined. The fuel is fed from
underneath, either continuously by a screw, or intermittently by plungers.
The principle upon which these stokers base their claims for efficiency and
smokelessness is that the green fuel is fed under the coked and burning coal,
the volatile gases from this fresh fuel being heated and ignited in their
passage through the hottest portion of the fire on the top. In the horizontal
classes of underfeed stokers, the action of a screw carries the fuel back
through a retort from which it passes upward, as the fuel above is consumed,
the ash being finally deposited on dead plates on either side of the [Pg 197]
retort, from which it can be removed. In the inclined class, the refuse is
carried downward to the rear of the furnace where there are dumping plates,
as in some of the overfeed types.
underfeed; and 3rd, traveling grate. The traveling grate stokers are
sometimes classed as overfeed but properly should be classed by themselves
as under certain conditions they are of the underfeed rather than the overfeed
type.
Overfeed Stokers in general may be divided into two classes, the distinction
being in the direction in which the coal is fed relative to the furnaces. In one
class the coal is fed into hoppers at the front end of the furnace onto grates
with an inclination downward toward the rear of about 45 degrees. These
grates are reciprocated, being made to take alternately level and inclined
positions and this motion gradually carries the fuel as it is burned toward the
rear and bottom of the furnace. At the bottom of the grates flat dumping
sections are supplied for completing the combustion and for cleaning. The
fuel is partly burned or coked on the upper portion of the grates, the volatile
gases driven off in this process for a perfect action being ignited and burned
in their passage over the bed of burning carbon lower on the grates, or on
becoming mixed with the hot gases in the furnace chamber. In the second
class the fuel is fed from the sides of the furnace for its full depth from front
to rear onto grates inclined toward the center of the furnace. It is moved by
rocking bars and is gradually carried to the bottom and center of the furnace
as combustion advances. Here some type of a so-called clinker breaker
removes the refuse.
Underfeed Stokers are either horizontal or inclined. The fuel is fed from
underneath, either continuously by a screw, or intermittently by plungers.
The principle upon which these stokers base their claims for efficiency and
smokelessness is that the green fuel is fed under the coked and burning coal,
the volatile gases from this fresh fuel being heated and ignited in their
passage through the hottest portion of the fire on the top. In the horizontal
classes of underfeed stokers, the action of a screw carries the fuel back
through a retort from which it passes upward, as the fuel above is consumed,
the ash being finally deposited on dead plates on either side of the [Pg 197]
retort, from which it can be removed. In the inclined class, the refuse is
carried downward to the rear of the furnace where there are dumping plates,
as in some of the overfeed types.
Page 273
Underfeed stokers are ordinarily operated with a forced blast, this in some
cases being operated by the same mechanism as the stoker drive, thus
automatically meeting the requirements of various combustion rates.
Traveling Grates are of the class best illustrated by chain grate stokers. As
implied by the name these consist of endless grates composed of short
sections of bars, passing over sprockets at the front and rear of the furnace.
Coal is fed by gravity onto the forward end of the grates through suitable
hoppers, is ignited under ignition arches and is carried with the grate toward
the rear of the furnace as its combustion progresses. When operated properly,
the combustion is completed as the fire reaches the end of the grate and the
refuse is carried over this rear end by the grate in making the turn over the
rear sprocket. In some cases auxiliary dumping grates at the rear of the chain
grates are used with success.
Chain grate stokers in general produce less smoke than either overfeed or
underfeed types, due to the fact that there are no cleaning periods necessary.
Such periods occur with the latter types of stokers at intervals depending
upon the character of the fuel used and the rate of combustion. With chain
grate stokers the cleaning is continuous and automatic, and no periods occur
when smoke will necessarily be produced.
In the earlier forms, chain grates had an objectionable feature in that the
admission of large amounts of excess air at the rear of the furnace through
the grates was possible. This objection has been largely overcome in recent
models by the use of some such device as the bridge wall water box and
suitable dampers. A distinct advantage of chain grates over other types is that
they can be withdrawn from the furnace for inspection or repairs without
interfering in any way with the boiler setting.
This class of stoker is particularly successful in burning low grades of coal
running high in ash and volatile matter which can only be burned with
difficulty on the other types. The cost of up-keep in a chain grate, properly
constructed and operated, is low in comparison with the same cost for other
stokers.
The Babcock & Wilcox chain grate is representative of this design of stoker.
cases being operated by the same mechanism as the stoker drive, thus
automatically meeting the requirements of various combustion rates.
Traveling Grates are of the class best illustrated by chain grate stokers. As
implied by the name these consist of endless grates composed of short
sections of bars, passing over sprockets at the front and rear of the furnace.
Coal is fed by gravity onto the forward end of the grates through suitable
hoppers, is ignited under ignition arches and is carried with the grate toward
the rear of the furnace as its combustion progresses. When operated properly,
the combustion is completed as the fire reaches the end of the grate and the
refuse is carried over this rear end by the grate in making the turn over the
rear sprocket. In some cases auxiliary dumping grates at the rear of the chain
grates are used with success.
Chain grate stokers in general produce less smoke than either overfeed or
underfeed types, due to the fact that there are no cleaning periods necessary.
Such periods occur with the latter types of stokers at intervals depending
upon the character of the fuel used and the rate of combustion. With chain
grate stokers the cleaning is continuous and automatic, and no periods occur
when smoke will necessarily be produced.
In the earlier forms, chain grates had an objectionable feature in that the
admission of large amounts of excess air at the rear of the furnace through
the grates was possible. This objection has been largely overcome in recent
models by the use of some such device as the bridge wall water box and
suitable dampers. A distinct advantage of chain grates over other types is that
they can be withdrawn from the furnace for inspection or repairs without
interfering in any way with the boiler setting.
This class of stoker is particularly successful in burning low grades of coal
running high in ash and volatile matter which can only be burned with
difficulty on the other types. The cost of up-keep in a chain grate, properly
constructed and operated, is low in comparison with the same cost for other
stokers.
The Babcock & Wilcox chain grate is representative of this design of stoker.
Page 274
Smoke—The question of smoke and smokelessness in burning fuels has
recently become a very important factor of the problem of combustion.
Cities and communities throughout the country have passed ordinances
relative to the quantities of smoke that may be emitted from a stack, and the
failure of operators to live up to the requirements of such ordinances,
resulting as it does in fines and annoyance, has brought their attention
forcibly to the matter.
The whole question of smoke and smokelessness is to a large extent a
comparative one. There are any number of plants burning a wide variety of
fuels in ordinary hand-fired furnaces, in extension furnaces and on automatic
stokers that are operating under service conditions, practically without
smoke. It is safe to say, however, that no plant will operate smokelessly
under any and all conditions of service, nor is there a plant in which the
degree of smokelessness does not depend largely upon the intelligence of the
operating force.
[Pg 198]
recently become a very important factor of the problem of combustion.
Cities and communities throughout the country have passed ordinances
relative to the quantities of smoke that may be emitted from a stack, and the
failure of operators to live up to the requirements of such ordinances,
resulting as it does in fines and annoyance, has brought their attention
forcibly to the matter.
The whole question of smoke and smokelessness is to a large extent a
comparative one. There are any number of plants burning a wide variety of
fuels in ordinary hand-fired furnaces, in extension furnaces and on automatic
stokers that are operating under service conditions, practically without
smoke. It is safe to say, however, that no plant will operate smokelessly
under any and all conditions of service, nor is there a plant in which the
degree of smokelessness does not depend largely upon the intelligence of the
operating force.
[Pg 198]
Page 275
Fig. 26. Babcock & Wilcox Boiler and Superheater Equipped with
Babcock & Wilcox Chain Grate Stoker.
This Setting has been Particularly Successful in Minimizing Smoke
When a condition arises in a boiler room requiring the fires to be brought up
quickly, the operatives in handling certain types of stokers will use their slice
bars freely to break up the green portion of the fire over the bed of partially
burned coal. [Pg 199] In fact, when a load is suddenly thrown on a station the
steam pressure can often be maintained only in this way, and such use of the
slice bar will cause smoke with the very best type of stoker. In a certain plant
using a highly volatile coal and operating boilers equipped with ordinary
hand-fired furnaces, extension hand-fired furnaces and stokers, in which the
Babcock & Wilcox Chain Grate Stoker.
This Setting has been Particularly Successful in Minimizing Smoke
When a condition arises in a boiler room requiring the fires to be brought up
quickly, the operatives in handling certain types of stokers will use their slice
bars freely to break up the green portion of the fire over the bed of partially
burned coal. [Pg 199] In fact, when a load is suddenly thrown on a station the
steam pressure can often be maintained only in this way, and such use of the
slice bar will cause smoke with the very best type of stoker. In a certain plant
using a highly volatile coal and operating boilers equipped with ordinary
hand-fired furnaces, extension hand-fired furnaces and stokers, in which the
Page 276
boilers with the different types of furnaces were on separate stacks, a
difference in smoke from the different types of furnaces was apparent at
light loads, but when a heavy load was thrown on the plant, all three stacks
would smoke to the same extent, and it was impossible to judge which type
of furnace was on one or the other of the stacks.
In hand-fired furnaces much can be accomplished by proper firing. A
combination of the alternate and spreading methods should be used, the coal
being fired evenly, quickly, lightly and often, and the fires worked as little as
possible. Smoke can be diminished by giving the gases a long travel under
the action of heated brickwork before they strike the boiler heating surfaces.
Air introduced over the fires and the use of heated arches, etc., for mingling
the air with the gases distilled from the coal will also diminish smoke.
Extension furnaces will undoubtedly lessen smoke where hand firing is used,
due to the increase in length of gas travel and the fact that this travel is
partially under heated brickwork. Where hand-fired grates are immediately
under the boiler tubes, and a high volatile coal is used, if sufficient
combustion space is not provided the volatile gases, distilled as soon as the
coal is thrown on the fire, strike the tube surfaces and are cooled below the
burning point before they are wholly consumed and pass through as smoke.
With an extension furnace, these volatile gases are acted upon by the radiant
heat from the extension furnace arch and this heat, together with the added
length of travel causes their more complete combustion before striking the
heating surfaces than in the former case.
Smoke may be diminished by employing a baffle arrangement which gives
the gases a fairly long travel under heated brickwork and by introducing air
above the fire. In many cases, however, special furnaces for smoke reduction
are installed at the expense of capacity and economy.
From the standpoint of smokelessness, undoubtedly the best results are
obtained with a good stoker, properly operated. As stated above, the best
stoker will cause smoke under certain conditions. Intelligently handled,
however, under ordinary operating conditions, stoker-fired furnaces are
much more nearly smokeless than those which are hand fired, and are, to all
intents and purposes, smokeless. In practically all stoker installations there
enters the element of time for combustion, the volatile gases as they are
distilled being acted upon by ignition or other arches before they strike the
difference in smoke from the different types of furnaces was apparent at
light loads, but when a heavy load was thrown on the plant, all three stacks
would smoke to the same extent, and it was impossible to judge which type
of furnace was on one or the other of the stacks.
In hand-fired furnaces much can be accomplished by proper firing. A
combination of the alternate and spreading methods should be used, the coal
being fired evenly, quickly, lightly and often, and the fires worked as little as
possible. Smoke can be diminished by giving the gases a long travel under
the action of heated brickwork before they strike the boiler heating surfaces.
Air introduced over the fires and the use of heated arches, etc., for mingling
the air with the gases distilled from the coal will also diminish smoke.
Extension furnaces will undoubtedly lessen smoke where hand firing is used,
due to the increase in length of gas travel and the fact that this travel is
partially under heated brickwork. Where hand-fired grates are immediately
under the boiler tubes, and a high volatile coal is used, if sufficient
combustion space is not provided the volatile gases, distilled as soon as the
coal is thrown on the fire, strike the tube surfaces and are cooled below the
burning point before they are wholly consumed and pass through as smoke.
With an extension furnace, these volatile gases are acted upon by the radiant
heat from the extension furnace arch and this heat, together with the added
length of travel causes their more complete combustion before striking the
heating surfaces than in the former case.
Smoke may be diminished by employing a baffle arrangement which gives
the gases a fairly long travel under heated brickwork and by introducing air
above the fire. In many cases, however, special furnaces for smoke reduction
are installed at the expense of capacity and economy.
From the standpoint of smokelessness, undoubtedly the best results are
obtained with a good stoker, properly operated. As stated above, the best
stoker will cause smoke under certain conditions. Intelligently handled,
however, under ordinary operating conditions, stoker-fired furnaces are
much more nearly smokeless than those which are hand fired, and are, to all
intents and purposes, smokeless. In practically all stoker installations there
enters the element of time for combustion, the volatile gases as they are
distilled being acted upon by ignition or other arches before they strike the
Page 277
heating surfaces. In many instances too, stokers are installed with an
extension beyond the boiler front, which gives an added length of travel
during which, the gases are acted upon by the radiant heat from the ignition
or supplementary arches, and here again we see the long travel giving time
for the volatile gases to be properly consumed.
To repeat, it must be emphatically borne in mind that the question of
smokelessness is largely one of degree, and dependent to an extent much
greater than is ordinarily appreciated upon the handling of the fuel and the
furnaces by the operators, be these furnaces hand fired or automatically
fired.
[Pg 200]
extension beyond the boiler front, which gives an added length of travel
during which, the gases are acted upon by the radiant heat from the ignition
or supplementary arches, and here again we see the long travel giving time
for the volatile gases to be properly consumed.
To repeat, it must be emphatically borne in mind that the question of
smokelessness is largely one of degree, and dependent to an extent much
greater than is ordinarily appreciated upon the handling of the fuel and the
furnaces by the operators, be these furnaces hand fired or automatically
fired.
[Pg 200]
Page 278
3520 Horse-power Installation of Babcock & Wilcox Boilers at the
Portland Railway, Light and Power Co., Portland, Ore. These Boilers
are Equipped with Wood Refuse Extension Furnaces at the Front and
Oil Burning Furnaces at the Mud Drum End
Portland Railway, Light and Power Co., Portland, Ore. These Boilers
are Equipped with Wood Refuse Extension Furnaces at the Front and
Oil Burning Furnaces at the Mud Drum End
Page 279
[Pg 201]
Page 280
SOLID FUELS OTHER THAN COAL AND THEIR COMBUSTION
Wood —Wood is vegetable tissue which has undergone no geological change. Usually the term is used to
designate those compact substances familiarly known as tree trunks and limbs. When newly cut, wood contains
moisture varying from 30 per cent to 50 per cent. When dried for a period of about a year in the atmosphere, the
moisture content will be reduced to 18 or 20 per cent.
TABLE 41 Wood is usually classified as hard wood, including oak, maple,
hickory, birch, walnut and beech; and soft wood, including pine,
ULTIMATE ANALYSES AND fir, spruce, elm, chestnut, poplar and willow. Contrary to general
CALORIFIC VALUES OF DRY WOOD opinion, the heat value per pound of soft wood is slightly greater
(GOTTLIEB) than the same value per pound of hard wood. Table 41 gives the
Kind B. t. u. chemical composition and the heat values of the common woods.
of C H N O Ash per Ordinarily the heating value of wood is considered equivalent to
Wood Pound 0.4 that of bituminous coal. In considering the calorific value of
Oak 50.16 6.02 0.09 43.360.37 8316 wood as given in this table , it is to be remembered that while this
value is based on air-dried wood, the moisture content is still
Ash 49.18 6.27 0.07 43.910.57 8480
about 20 per cent of the whole, and the heat produced in burning
Elm 48.99 6.20 0.06 44.250.50 8510
it will be diminished by this amount and by the heat required to
Beech 49.06 6.11 0.09 44.170.57 8391 evaporate the moisture and superheat it to the temperature of the
Birch 48.88 6.06 0.10 44.670.29 8586 gases. The heat so absorbed may be calculated by the formula
Fir 50.36 5.92 0.05 43.390.28 9063 giving the loss due to moisture in the fuel, and the net calorific
Pine 50.31 6.20 0.04 43.080.37 9153 value determined.
Poplar 49.37 6.21 0.96 41.601.86 7834 [40]
Willow 49.96 5.96 0.96 39.563.37 7926 [40] In designing furnaces for burning wood, the question resolves
itself into: 1st, the essential elements to give maximum capacity
and efficiency with this class of fuel; and 2nd, the construction which will entail the least labor in handling and
feeding the fuel and removing the refuse after combustion.
Wood, as used commercially for steam generating purposes, is usually a waste product from some industrial
process. At the present time refuse from lumber and sawmills forms by far the greater part of this class of fuel. In
such refuse the moisture may run as high as 60 per cent and the composition of the fuel may vary over wide ranges
during different portions of the mill operation. The fuel consists of sawdust, “hogged” wood and slabs, and the
percentage of each of these constituents may vary greatly. Hogged wood is mill refuse and logs that have been
passed through a “hogging machine” or macerator. This machine, through the action of revolving knives, cuts or
shreds the wood into a state in which it may readily be handled as fuel.
[Pg 202]
Table 42 gives the moisture content and heat value of typical sawmill refuse from various woods.
TABLE 42
MOISTURE AND CALORIFIC VALUE OF SAWMILL REFUSE
B. t. u.
Per Cent
Kind of Wood Nature of Refuse per Pound
Moisture
Dry Fuel
Mexican White Pine Sawdust and Hog Chips 51.90 9020
Yosemite Sugar Pine Sawdust and Hog Chips 62.85 9010
Redwood 75%, Douglas Fir 25% Sawdust, Box Mill Refuse and Hog 42.20 8977 [41]
Redwood Sawdust and Hog Chips 52.98 9040 [41]
Redwood Sawdust and Hog Chips 49.11 9204 [41]
Fir, Hemlock, Spruce and Cedar Sawdust 42.06 8949 [41]
Wood —Wood is vegetable tissue which has undergone no geological change. Usually the term is used to
designate those compact substances familiarly known as tree trunks and limbs. When newly cut, wood contains
moisture varying from 30 per cent to 50 per cent. When dried for a period of about a year in the atmosphere, the
moisture content will be reduced to 18 or 20 per cent.
TABLE 41 Wood is usually classified as hard wood, including oak, maple,
hickory, birch, walnut and beech; and soft wood, including pine,
ULTIMATE ANALYSES AND fir, spruce, elm, chestnut, poplar and willow. Contrary to general
CALORIFIC VALUES OF DRY WOOD opinion, the heat value per pound of soft wood is slightly greater
(GOTTLIEB) than the same value per pound of hard wood. Table 41 gives the
Kind B. t. u. chemical composition and the heat values of the common woods.
of C H N O Ash per Ordinarily the heating value of wood is considered equivalent to
Wood Pound 0.4 that of bituminous coal. In considering the calorific value of
Oak 50.16 6.02 0.09 43.360.37 8316 wood as given in this table , it is to be remembered that while this
value is based on air-dried wood, the moisture content is still
Ash 49.18 6.27 0.07 43.910.57 8480
about 20 per cent of the whole, and the heat produced in burning
Elm 48.99 6.20 0.06 44.250.50 8510
it will be diminished by this amount and by the heat required to
Beech 49.06 6.11 0.09 44.170.57 8391 evaporate the moisture and superheat it to the temperature of the
Birch 48.88 6.06 0.10 44.670.29 8586 gases. The heat so absorbed may be calculated by the formula
Fir 50.36 5.92 0.05 43.390.28 9063 giving the loss due to moisture in the fuel, and the net calorific
Pine 50.31 6.20 0.04 43.080.37 9153 value determined.
Poplar 49.37 6.21 0.96 41.601.86 7834 [40]
Willow 49.96 5.96 0.96 39.563.37 7926 [40] In designing furnaces for burning wood, the question resolves
itself into: 1st, the essential elements to give maximum capacity
and efficiency with this class of fuel; and 2nd, the construction which will entail the least labor in handling and
feeding the fuel and removing the refuse after combustion.
Wood, as used commercially for steam generating purposes, is usually a waste product from some industrial
process. At the present time refuse from lumber and sawmills forms by far the greater part of this class of fuel. In
such refuse the moisture may run as high as 60 per cent and the composition of the fuel may vary over wide ranges
during different portions of the mill operation. The fuel consists of sawdust, “hogged” wood and slabs, and the
percentage of each of these constituents may vary greatly. Hogged wood is mill refuse and logs that have been
passed through a “hogging machine” or macerator. This machine, through the action of revolving knives, cuts or
shreds the wood into a state in which it may readily be handled as fuel.
[Pg 202]
Table 42 gives the moisture content and heat value of typical sawmill refuse from various woods.
TABLE 42
MOISTURE AND CALORIFIC VALUE OF SAWMILL REFUSE
B. t. u.
Per Cent
Kind of Wood Nature of Refuse per Pound
Moisture
Dry Fuel
Mexican White Pine Sawdust and Hog Chips 51.90 9020
Yosemite Sugar Pine Sawdust and Hog Chips 62.85 9010
Redwood 75%, Douglas Fir 25% Sawdust, Box Mill Refuse and Hog 42.20 8977 [41]
Redwood Sawdust and Hog Chips 52.98 9040 [41]
Redwood Sawdust and Hog Chips 49.11 9204 [41]
Fir, Hemlock, Spruce and Cedar Sawdust 42.06 8949 [41]
Page 281
It is essential in the burning of this class of fuel that a large combustion space be supplied, and on account of the
usually high moisture content there should be much heated brickwork to radiate heat to the fuel bed and thus
evaporate the moisture. Extension furnaces of the proper size are usually essential for good results and when this
fuel is used alone, grates dropped to the floor line with an ashpit below give additional volume for combustion and
space for maintaining a thick fuel bed. A thick fuel bed is necessary in order to avoid excessive quantities of air
passing through the boiler. Where the fuel consists of hogged wood and sawdust alone, it is best to feed it
automatically into the furnace through chutes on the top of the extension. The best results are secured when the
fuel is allowed to pile up in the furnace to a height of 3 or 4 feet in the form of a cone under each chute. The fuel
burns best when not disturbed in the furnace. Each fuel chute, when a proper distance from the grates and with the
piles maintained at their proper height, will supply about 30 or 35 square feet of grate surface. While large
quantities of air are required for burning this fuel, excess air is as harmful as with coal, and care must be taken that
such an excess is not admitted through fire doors or fuel chutes. A strong natural draft usually is preferable to a
blast with this fuel. The action of blast is to make the regulation of the furnace conditions more difficult and to
blow over unconsumed fuel on the heating surfaces and into the stack. This unconsumed fuel settling in portions of
the setting out of the direct path of the gases will have a tendency to ignite provided any air reaches it, with results
harmful to the setting and breeching connection. This action is particularly objectionable if these particles are
carried over into the base of a stack, where they will settle below the point at which the flue enters and if ignited
may cause the stack to become overheated and buckle.
Whether natural draft or blast is used, much of the fuel is carried onto the heating surfaces and these should be
cleaned regularly to maintain a good efficiency. Collecting chambers in various portions of the setting should be
provided for this unconsumed fuel, and these should be kept clean.
With proper draft conditions, 150 pounds of this fuel containing about 30 to 40 per cent of moisture can be burned
per square foot of grate surface per hour, and in a properly designed furnace one square foot of grate surface can
develop from 5 to 6 boiler horse power. Where the wood contains 50 per cent of moisture or over, [Pg 203] it is not
usually safe to figure on obtaining more than 3 to 4 horse power per square foot of grate surface.
Dry sawdust, chips and blocks are also used as fuel in many wood-working industries. Here, as with the wet wood,
ample combustion space should be supplied, but as this fuel is ordinarily kiln dried, large brickwork surfaces in the
furnace are not necessary for the evaporation of moisture in the fuel. This fuel may be burned in extension furnaces
though these are not required unless they are necessary to secure an added furnace volume, to get in sufficient
grate surface, or where such an arrangement must be used to allow for a fuel bed of sufficient thickness. Depth of
fuel bed with the dry fuel is as important as with the moist fuel. If extension furnaces are used with this dry wood,
care must be taken in their design that there is no excessive throttling of the gases in the furnace, or brickwork
trouble will result. In Babcock & Wilcox boilers this fuel may be burned without extension furnaces, provided that
the boilers are set at a sufficient height to provide ample combustion space and to allow for proper depth of fuel
bed. Sometimes this is gained by lowering the grates to the floor line and excavating for an ashpit. Where the fuel
is largely sawdust, it may be introduced over the fire doors through inclined chutes. The old methods of handling
and collecting sawdust by means of air suction and blast were such that the amount of air admitted through such
chutes was excessive, but with improved methods the amount of air so admitted may be reduced to a negligible
quantity. The blocks and refuse which cannot be handled through chutes may be fired through fire doors in the
front of the boiler, which should be made sufficiently large to accommodate the larger sizes of fuel. As with wet
fuel, there will be a quantity of unconsumed wood carried over and the heating surfaces must be kept clean.
In a few localities cord wood is burned. With this as with other classes of wood fuel, a large combustion space is
an essential feature. The percentage of moisture in cord wood may make it necessary to use an extension furnace,
but ordinarily this is not required. Ample combustion space is in most cases secured by dropping the grates to the
floor line, large double-deck fire doors being supplied at the usual fire door level through which the wood is
thrown by hand. Air is admitted under the grates through an excavated ashpit. The side, front and rear walls of the
furnace should be corbelled out to cover about one-third of the total grate surface. This prevents cold air from
laneing up the sides of the furnace and also reduces the grate surface. Cord wood and slabs form an open fire
through which the frictional loss of the air is much less than in the case of sawdust or hogged material. The
combustion rate with cord wood is, therefore, higher and the grate surface may be considerably reduced. Such
wood is usually cut in lengths of 4 feet or 4 feet 6 inches, and the depth of the grates should be kept approximately
5 feet to get the best results.
usually high moisture content there should be much heated brickwork to radiate heat to the fuel bed and thus
evaporate the moisture. Extension furnaces of the proper size are usually essential for good results and when this
fuel is used alone, grates dropped to the floor line with an ashpit below give additional volume for combustion and
space for maintaining a thick fuel bed. A thick fuel bed is necessary in order to avoid excessive quantities of air
passing through the boiler. Where the fuel consists of hogged wood and sawdust alone, it is best to feed it
automatically into the furnace through chutes on the top of the extension. The best results are secured when the
fuel is allowed to pile up in the furnace to a height of 3 or 4 feet in the form of a cone under each chute. The fuel
burns best when not disturbed in the furnace. Each fuel chute, when a proper distance from the grates and with the
piles maintained at their proper height, will supply about 30 or 35 square feet of grate surface. While large
quantities of air are required for burning this fuel, excess air is as harmful as with coal, and care must be taken that
such an excess is not admitted through fire doors or fuel chutes. A strong natural draft usually is preferable to a
blast with this fuel. The action of blast is to make the regulation of the furnace conditions more difficult and to
blow over unconsumed fuel on the heating surfaces and into the stack. This unconsumed fuel settling in portions of
the setting out of the direct path of the gases will have a tendency to ignite provided any air reaches it, with results
harmful to the setting and breeching connection. This action is particularly objectionable if these particles are
carried over into the base of a stack, where they will settle below the point at which the flue enters and if ignited
may cause the stack to become overheated and buckle.
Whether natural draft or blast is used, much of the fuel is carried onto the heating surfaces and these should be
cleaned regularly to maintain a good efficiency. Collecting chambers in various portions of the setting should be
provided for this unconsumed fuel, and these should be kept clean.
With proper draft conditions, 150 pounds of this fuel containing about 30 to 40 per cent of moisture can be burned
per square foot of grate surface per hour, and in a properly designed furnace one square foot of grate surface can
develop from 5 to 6 boiler horse power. Where the wood contains 50 per cent of moisture or over, [Pg 203] it is not
usually safe to figure on obtaining more than 3 to 4 horse power per square foot of grate surface.
Dry sawdust, chips and blocks are also used as fuel in many wood-working industries. Here, as with the wet wood,
ample combustion space should be supplied, but as this fuel is ordinarily kiln dried, large brickwork surfaces in the
furnace are not necessary for the evaporation of moisture in the fuel. This fuel may be burned in extension furnaces
though these are not required unless they are necessary to secure an added furnace volume, to get in sufficient
grate surface, or where such an arrangement must be used to allow for a fuel bed of sufficient thickness. Depth of
fuel bed with the dry fuel is as important as with the moist fuel. If extension furnaces are used with this dry wood,
care must be taken in their design that there is no excessive throttling of the gases in the furnace, or brickwork
trouble will result. In Babcock & Wilcox boilers this fuel may be burned without extension furnaces, provided that
the boilers are set at a sufficient height to provide ample combustion space and to allow for proper depth of fuel
bed. Sometimes this is gained by lowering the grates to the floor line and excavating for an ashpit. Where the fuel
is largely sawdust, it may be introduced over the fire doors through inclined chutes. The old methods of handling
and collecting sawdust by means of air suction and blast were such that the amount of air admitted through such
chutes was excessive, but with improved methods the amount of air so admitted may be reduced to a negligible
quantity. The blocks and refuse which cannot be handled through chutes may be fired through fire doors in the
front of the boiler, which should be made sufficiently large to accommodate the larger sizes of fuel. As with wet
fuel, there will be a quantity of unconsumed wood carried over and the heating surfaces must be kept clean.
In a few localities cord wood is burned. With this as with other classes of wood fuel, a large combustion space is
an essential feature. The percentage of moisture in cord wood may make it necessary to use an extension furnace,
but ordinarily this is not required. Ample combustion space is in most cases secured by dropping the grates to the
floor line, large double-deck fire doors being supplied at the usual fire door level through which the wood is
thrown by hand. Air is admitted under the grates through an excavated ashpit. The side, front and rear walls of the
furnace should be corbelled out to cover about one-third of the total grate surface. This prevents cold air from
laneing up the sides of the furnace and also reduces the grate surface. Cord wood and slabs form an open fire
through which the frictional loss of the air is much less than in the case of sawdust or hogged material. The
combustion rate with cord wood is, therefore, higher and the grate surface may be considerably reduced. Such
wood is usually cut in lengths of 4 feet or 4 feet 6 inches, and the depth of the grates should be kept approximately
5 feet to get the best results.
Page 282
Bagasse —Bagasse is the refuse of sugar cane from which the juice has been extracted by pressure between the
rolls of the mill. From the start of the sugar industry bagasse has been considered the natural fuel for sugar
plantations, and in view of the importance of the industry a word of history relative to the use of this fuel is not out
of place.
When the manufacture of sugar was in its infancy the cane was passed through but a single mill and the defecation
and concentration of the saccharine juice took place in a series of vessels mounted one after another over a
common fire at one end and connected to a stack at the opposite end. This primitive method was known in [Pg 204]
the English colonies as the “Open Wall” and in the Spanish-American countries as the “Jamaica Train”.
The evaporation and concentration of the juice in the open air and over a direct fire required such quantities of
fuel, and the bagasse, in fact, played such an important part in the manufacture of sugar, that oftentimes the degree
of extraction, which was already low, would be sacrificed to the necessity of obtaining a bagasse that might be
readily burned.
The furnaces in use with these methods were as primitive as the rest of the apparatus, and the bagasse could be
burned in them only by first drying it. This naturally required an enormous quantity of handling of the fuel in
spreading and collecting and frequently entailed a shutting down of the mill, because a shower would spoil the
supply which had been dried.
The difficulties arising from the necessity of drying this fuel caused a widespread attempt on the part of inventors
to the turning out of a furnace which would successfully burn green bagasse. Some of the designs were more or
less clever, and about the year 1880 several such green bagasse furnaces were installed. These did not come up to
expectations, however, and almost invariably they were abandoned and recourse had to be taken to the old method
of drying in the sun.
From 1880 the new era in the sugar industry may be dated. Slavery was almost universally abolished and it
became necessary to pay for labor. The cost of production was thus increased, while growing competition of
European beet sugar lowered the prices. The only remedy for the new state of affairs was the cheapening of the
production by the increase of extraction and improvement in manufacture. The double mill took the place of the
single, the open wall method of extraction was replaced by vacuum evaporative apparatus and centrifugal
machines were introduced to do the work of the great curing houses. As opposed to these improvements, however,
the steam plants remained as they started, consisting of double flue boilers externally fired with dry bagasse.
On several of the plantations horizontal multitubular boilers externally fired were installed and at the time were
considered the acme of perfection. Numerous attempts were made to burn the bagasse green, among others the step
grates imported from Louisiana and known as the Leon Marie furnaces, but satisfactory results were obtained in
none of the appliances tried.
The Babcock & Wilcox Co. at this time turned their attention to the problem with the results which ultimately led
to its solution. Their New Orleans representative, Mr. Frederick Cook, invented a hot forced blast bagasse furnace
and conveyed the patent rights to this company. This furnace while not as efficient as the standard of to-day, and
expensive in its construction, did, nevertheless, burn the bagasse green and enabled the boilers to develop their
normal rated capacity. The first furnace of this type was installed at the Southwood and Mt. Houmas plantations
and on a small plantation in Florida. About the year 1888 two furnaces were erected in Cuba, one on the plantation
Senado and the other at the Central Hormiguero. The results obtained with these furnaces were so remarkable in
comparison with what had previously been accomplished that the company was overwhelmed with orders. The
expense of auxiliary fuel, usually wood, which was costly and indispensable in rainy weather, was done away with
and as the mill could be operated on bagasse alone, the steam production and the factory work could be regulated
with natural increase in daily output.
[Pg 205]
Progress and improvement in the manufacture itself was going on at a remarkable rate, the single grinding had
been replaced by a double grinding, this in turn by a third grinding, and finally the maceration and dilution of the
bagasse was carried to the extraction of practically the last trace of sugar contained in it. The quantity of juice to be
rolls of the mill. From the start of the sugar industry bagasse has been considered the natural fuel for sugar
plantations, and in view of the importance of the industry a word of history relative to the use of this fuel is not out
of place.
When the manufacture of sugar was in its infancy the cane was passed through but a single mill and the defecation
and concentration of the saccharine juice took place in a series of vessels mounted one after another over a
common fire at one end and connected to a stack at the opposite end. This primitive method was known in [Pg 204]
the English colonies as the “Open Wall” and in the Spanish-American countries as the “Jamaica Train”.
The evaporation and concentration of the juice in the open air and over a direct fire required such quantities of
fuel, and the bagasse, in fact, played such an important part in the manufacture of sugar, that oftentimes the degree
of extraction, which was already low, would be sacrificed to the necessity of obtaining a bagasse that might be
readily burned.
The furnaces in use with these methods were as primitive as the rest of the apparatus, and the bagasse could be
burned in them only by first drying it. This naturally required an enormous quantity of handling of the fuel in
spreading and collecting and frequently entailed a shutting down of the mill, because a shower would spoil the
supply which had been dried.
The difficulties arising from the necessity of drying this fuel caused a widespread attempt on the part of inventors
to the turning out of a furnace which would successfully burn green bagasse. Some of the designs were more or
less clever, and about the year 1880 several such green bagasse furnaces were installed. These did not come up to
expectations, however, and almost invariably they were abandoned and recourse had to be taken to the old method
of drying in the sun.
From 1880 the new era in the sugar industry may be dated. Slavery was almost universally abolished and it
became necessary to pay for labor. The cost of production was thus increased, while growing competition of
European beet sugar lowered the prices. The only remedy for the new state of affairs was the cheapening of the
production by the increase of extraction and improvement in manufacture. The double mill took the place of the
single, the open wall method of extraction was replaced by vacuum evaporative apparatus and centrifugal
machines were introduced to do the work of the great curing houses. As opposed to these improvements, however,
the steam plants remained as they started, consisting of double flue boilers externally fired with dry bagasse.
On several of the plantations horizontal multitubular boilers externally fired were installed and at the time were
considered the acme of perfection. Numerous attempts were made to burn the bagasse green, among others the step
grates imported from Louisiana and known as the Leon Marie furnaces, but satisfactory results were obtained in
none of the appliances tried.
The Babcock & Wilcox Co. at this time turned their attention to the problem with the results which ultimately led
to its solution. Their New Orleans representative, Mr. Frederick Cook, invented a hot forced blast bagasse furnace
and conveyed the patent rights to this company. This furnace while not as efficient as the standard of to-day, and
expensive in its construction, did, nevertheless, burn the bagasse green and enabled the boilers to develop their
normal rated capacity. The first furnace of this type was installed at the Southwood and Mt. Houmas plantations
and on a small plantation in Florida. About the year 1888 two furnaces were erected in Cuba, one on the plantation
Senado and the other at the Central Hormiguero. The results obtained with these furnaces were so remarkable in
comparison with what had previously been accomplished that the company was overwhelmed with orders. The
expense of auxiliary fuel, usually wood, which was costly and indispensable in rainy weather, was done away with
and as the mill could be operated on bagasse alone, the steam production and the factory work could be regulated
with natural increase in daily output.
[Pg 205]
Progress and improvement in the manufacture itself was going on at a remarkable rate, the single grinding had
been replaced by a double grinding, this in turn by a third grinding, and finally the maceration and dilution of the
bagasse was carried to the extraction of practically the last trace of sugar contained in it. The quantity of juice to be
Page 283
treated was increased in this way 20 or 30 per cent but was accompanied by the reduction to a minimum of the
bagasse available as a fuel, and led to demands upon the furnace beyond its capacity.
With the improvements in the manufacture, planters had been compelled to make enormous sacrifices to change
radically their systems, and the heavy disbursement necessary for mill apparatus left few in a financial position to
make costly installations of good furnaces. The necessity of turning to something cheap in furnace construction but
which was nevertheless better than the early method of burning the fuel dry led to the invention of numerous
furnaces by all classes of engineers regardless of their knowledge of the subject and based upon no experience.
None of the furnaces thus produced were in any sense inventions but were more or less barefaced infringements of
the patents of The Babcock & Wilcox Co. As the company could not protect its rights without hurting its clients,
who in many cases against their own will were infringing upon these patents, and as on the other hand they were
anxious to do something to meet the wants of the planters, a series of experiments were started, at their own rather
than at their customers’ expense, with a view to developing a furnace which, without being as expensive, would
still fulfill all the requirements of the manufacturer. The result was the cold blast green bagasse furnace which is
now offered, and it has been adopted as standard for this class of work after years of study and observation in our
installations in the sugar countries of the world. Such a furnace is described later in considering the combustion of
bagasse.
Composition and Calorific Value of Bagasse —The proportion of fiber contained in the cane and density of the
juice are important factors in the relation the bagasse fuel will have to the total fuel necessary to generate the steam
required in a mill’s operation. A cane rich in wood fiber produces more bagasse than a poor one and a thicker juice
is subject to a higher degree of dilution than one not so rich.
Besides the percentage of bagasse in the cane, its physical condition has a bearing on its calorific value. The
factors here entering are the age at which the cane must be cut, the locality in which it is grown, etc. From the
analysis of any sample of bagasse its approximate calorific value may be calculated from the formula,
8550F + 7119S + 6750G - 972W
B. t. u. per pound bagasse = –––––––––––––––––––––––––––––––––––––––––––––––––––––– ( 22 )
100
Where F = per cent of fiber in cane, S = per cent sucrose, G = per cent glucose, W = per cent water.
This formula gives the total available heat per pound of bagasse, that is, the heat generated per pound less the heat
required to evaporate its moisture and superheat the steam thus formed to the temperature of the stack gases.
Three samples of bagasse in which the ash is assumed to be 3 per cent give from the formula:
F = 50 S and G = 4.5 W = 42.5 B. t. u. = 4183
F = 40 S and G = 6.0 W = 51.0 B. t. u. = 3351
F = 33.3 S and G = 7.0 W = 56.7 B. t. u. = 2797
[Pg 206]
A sample of Java bagasse having F = 46.5, S = 4.50, G = 0.5, W = 47.5 gives B. t. u. 3868.
These figures show that the dryer the bagasse is crushed, the higher the calorific value, though this is accompanied
by a decrease in sucrose. The explanation lies in the fact that the presence of sucrose in an analysis is accompanied
by a definite amount of water, and that the residual juice contains sufficient organic substance to evaporate the
water present when a fuel is burned in a furnace. For example, assume the residual juice (100 per cent) to contain
12 per cent organic matter. From the constant in formula,
12 × 7119 (100 - 12) × 972
––––––––––––––––– = 854.3 and ––––––––––––––––––––––––– = 855.4.
100 100
bagasse available as a fuel, and led to demands upon the furnace beyond its capacity.
With the improvements in the manufacture, planters had been compelled to make enormous sacrifices to change
radically their systems, and the heavy disbursement necessary for mill apparatus left few in a financial position to
make costly installations of good furnaces. The necessity of turning to something cheap in furnace construction but
which was nevertheless better than the early method of burning the fuel dry led to the invention of numerous
furnaces by all classes of engineers regardless of their knowledge of the subject and based upon no experience.
None of the furnaces thus produced were in any sense inventions but were more or less barefaced infringements of
the patents of The Babcock & Wilcox Co. As the company could not protect its rights without hurting its clients,
who in many cases against their own will were infringing upon these patents, and as on the other hand they were
anxious to do something to meet the wants of the planters, a series of experiments were started, at their own rather
than at their customers’ expense, with a view to developing a furnace which, without being as expensive, would
still fulfill all the requirements of the manufacturer. The result was the cold blast green bagasse furnace which is
now offered, and it has been adopted as standard for this class of work after years of study and observation in our
installations in the sugar countries of the world. Such a furnace is described later in considering the combustion of
bagasse.
Composition and Calorific Value of Bagasse —The proportion of fiber contained in the cane and density of the
juice are important factors in the relation the bagasse fuel will have to the total fuel necessary to generate the steam
required in a mill’s operation. A cane rich in wood fiber produces more bagasse than a poor one and a thicker juice
is subject to a higher degree of dilution than one not so rich.
Besides the percentage of bagasse in the cane, its physical condition has a bearing on its calorific value. The
factors here entering are the age at which the cane must be cut, the locality in which it is grown, etc. From the
analysis of any sample of bagasse its approximate calorific value may be calculated from the formula,
8550F + 7119S + 6750G - 972W
B. t. u. per pound bagasse = –––––––––––––––––––––––––––––––––––––––––––––––––––––– ( 22 )
100
Where F = per cent of fiber in cane, S = per cent sucrose, G = per cent glucose, W = per cent water.
This formula gives the total available heat per pound of bagasse, that is, the heat generated per pound less the heat
required to evaporate its moisture and superheat the steam thus formed to the temperature of the stack gases.
Three samples of bagasse in which the ash is assumed to be 3 per cent give from the formula:
F = 50 S and G = 4.5 W = 42.5 B. t. u. = 4183
F = 40 S and G = 6.0 W = 51.0 B. t. u. = 3351
F = 33.3 S and G = 7.0 W = 56.7 B. t. u. = 2797
[Pg 206]
A sample of Java bagasse having F = 46.5, S = 4.50, G = 0.5, W = 47.5 gives B. t. u. 3868.
These figures show that the dryer the bagasse is crushed, the higher the calorific value, though this is accompanied
by a decrease in sucrose. The explanation lies in the fact that the presence of sucrose in an analysis is accompanied
by a definite amount of water, and that the residual juice contains sufficient organic substance to evaporate the
water present when a fuel is burned in a furnace. For example, assume the residual juice (100 per cent) to contain
12 per cent organic matter. From the constant in formula,
12 × 7119 (100 - 12) × 972
––––––––––––––––– = 854.3 and ––––––––––––––––––––––––– = 855.4.
100 100
Page 284
That is, the moisture in a juice containing 12 per cent of sugar will be evaporated by the heat developed by the
combustion of the contained sugar. It would, therefore, appear that a bagasse containing such juice has a calorific
value due only to its fiber content. This is, of course, true only where the highest products of oxidization are
formed during the combustion of the organic matter. This is not strictly the case, especially with a bagasse of a
high moisture content which will not burn properly but which smoulders and produces a large quantity of products
of destructive distillation, chiefly heavy hydrocarbons, which escape unburnt. The reasoning, however, is sufficient
to explain the steam making properties of bagasse of a low sucrose content, such as are secured in Java, as when
the sucrose content is lower, the heat value is increased by extracting more juice, and hence more sugar from it.
The sugar operations in Java exemplify this and show that with a high dilution by maceration and heavy pressure
the bagasse meets all of the steam requirements of the mills without auxiliary fuel.
A high percentage of silica or salts in bagasse has sometimes been ascribed as the reason for the tendency to
smoulder in certain cases of soft fiber bagasse. This, however, is due to the large moisture content of the sample
resulting directly from the nature of the cane. Soluble salts in the bagasse has also been given as the explanation of
such smouldering action of the fire, but here too the explanation lies solely in the high moisture content, this
resulting in the development of only sufficient heat to evaporate the moisture.
TABLE 43
ANALYSES AND CALORIFIC VALUES OF
BAGASSE
B. t. u.
per
Source Moisture C H O N Ash Pound
Dry
Bagasse
Cuba 51.50 43.15 6.00 47.95 … 2.90 7985
Cuba 49.10 43.74 6.08 48.61 … 1.57 8300
Cuba 42.50 43.61 6.06 48.45 … 1.88 8240
Cuba 51.61 46.80 5.34 46.35 … 1.51 …
Cuba 52.80 46.78 5.74 45.38 … 2.10 …
Porto Rico 41.60 44.28 6.66 47.100.411.35 8359
Porto Rico 43.50 44.21 6.31 47.720.411.35 8386
Porto Rico 44.20 44.92 6.27 46.500.411.90 8380
Louisiana 52.10 … … … … 2.27 8230
Louisiana 54.00 … … … … … 8370
Louisiana 51.80 … … … … … 8371
Java … 46.03 6.56 45.550.181.68 8681
Table 43 gives the analyses and heat values of bagasse from various localities. Table 44 gives the value of mill
bagasse at different extractions, which data may be of [Pg 207] service in making approximations as to its fuel value
as compared with that of other fuels.
TABLE 44
ANALYSES AND CALORIFIC VALUES OF BAGASSE
combustion of the contained sugar. It would, therefore, appear that a bagasse containing such juice has a calorific
value due only to its fiber content. This is, of course, true only where the highest products of oxidization are
formed during the combustion of the organic matter. This is not strictly the case, especially with a bagasse of a
high moisture content which will not burn properly but which smoulders and produces a large quantity of products
of destructive distillation, chiefly heavy hydrocarbons, which escape unburnt. The reasoning, however, is sufficient
to explain the steam making properties of bagasse of a low sucrose content, such as are secured in Java, as when
the sucrose content is lower, the heat value is increased by extracting more juice, and hence more sugar from it.
The sugar operations in Java exemplify this and show that with a high dilution by maceration and heavy pressure
the bagasse meets all of the steam requirements of the mills without auxiliary fuel.
A high percentage of silica or salts in bagasse has sometimes been ascribed as the reason for the tendency to
smoulder in certain cases of soft fiber bagasse. This, however, is due to the large moisture content of the sample
resulting directly from the nature of the cane. Soluble salts in the bagasse has also been given as the explanation of
such smouldering action of the fire, but here too the explanation lies solely in the high moisture content, this
resulting in the development of only sufficient heat to evaporate the moisture.
TABLE 43
ANALYSES AND CALORIFIC VALUES OF
BAGASSE
B. t. u.
per
Source Moisture C H O N Ash Pound
Dry
Bagasse
Cuba 51.50 43.15 6.00 47.95 … 2.90 7985
Cuba 49.10 43.74 6.08 48.61 … 1.57 8300
Cuba 42.50 43.61 6.06 48.45 … 1.88 8240
Cuba 51.61 46.80 5.34 46.35 … 1.51 …
Cuba 52.80 46.78 5.74 45.38 … 2.10 …
Porto Rico 41.60 44.28 6.66 47.100.411.35 8359
Porto Rico 43.50 44.21 6.31 47.720.411.35 8386
Porto Rico 44.20 44.92 6.27 46.500.411.90 8380
Louisiana 52.10 … … … … 2.27 8230
Louisiana 54.00 … … … … … 8370
Louisiana 51.80 … … … … … 8371
Java … 46.03 6.56 45.550.181.68 8681
Table 43 gives the analyses and heat values of bagasse from various localities. Table 44 gives the value of mill
bagasse at different extractions, which data may be of [Pg 207] service in making approximations as to its fuel value
as compared with that of other fuels.
TABLE 44
ANALYSES AND CALORIFIC VALUES OF BAGASSE
Page 285
Pounds
B. t. u. Value per
Fiber Sugar Molasses of
Pound of Bagasse
Per Bagasse
Cent Total Heat Equivalent
Extraction Per Heat Required Heat to one
of Cent Per Fuel Per Fuel Per Fuel Developed to Available Pound
Weight Moisture Cent Value, Cent Value, Cent Value, per Evaporate for of Coal of
of in in B. t. in B. t. in B. t. Pound of Moisture Steam 14,000
Cane Bagasse Bagasse u. Bagasse u. Bagasse u. Bagasse [42] Generation B. t. u.
BASED UPON CANE OF 12 PER CENT FIBER AND JUICE CONTAINING 18 PER CENT OF SOLID
MATTER.
REPRESENTING TROPICAL CONDITIONS
75 42.64 48.00 3996 6.24 451 3.12 217 4664 525 4139 3.38
77 39.22 52.17 4343 5.74 414 2.87 200 4958 483 4475 3.13
79 35.15 57.14 4757 5.14 371 2.57 179 5307 433 4874 2.87
81 30.21 63.16 5258 4.42 319 2.21 154 5731 372 5359 2.61
83 24.12 70.59 5877 3.53 256 1.76 122 6255 297 5958 2.35
85 16.20 80.00 6660 2.40 173 1.20 83 6916 200 6716 2.08
BASED UPON CANE OF 10 PER CENT FIBER AND JUICE CONTAINING 15 PER CENT OF SOLID
MATTER.
REPRESENTING LOUISIANA CONDITIONS
75 51.00 40.00 3330 6.00 433 3.00 209 3972 678 3294 4.25
77 48.07 43.45 3617 5.66 409 2.82 196 4222 592 3630 3.86
79 44.52 47.62 3964 5.24 378 2.62 182 4524 548 3976 3.52
81 40.18 52.63 4381 4.73 342 2.36 164 4887 495 4392 3.19
83 35.00 58.82 4897 4.12 298 2.06 143 5436 431 5005 2.80
85 28.33 66.67 5550 3.33 241 1.67 116 5907 349 5558 2.52
Furnace Design and the Combustion of Bagasse —With the advance in sugar manufacture there came, as
described, a decrease in the amount of bagasse available for fuel. As the general efficiency of a plant of this
description is measured by the amount of auxiliary fuel required per ton of cane, the relative importance of the
furnace design for the burning of this fuel is apparent.
In modern practice, under certain conditions of mill operation, and with bagasse of certain physical properties, the
bagasse available from the cane ground will meet the total steam requirements of the plant as a whole; such
conditions prevail, as described, in Java. In the United States, Cuba, Porto Rico and like countries, however,
auxiliary fuel is almost universally a necessity. The amount will vary, depending to a great extent upon the
proportion of fiber in the cane, which varies widely with the locality and with the age at which it is cut, and to a
lesser extent upon the degree of purity of the manufactured sugar, the use of the maceration water and the
efficiency of the mill apparatus as a whole.
[Pg 208]
B. t. u. Value per
Fiber Sugar Molasses of
Pound of Bagasse
Per Bagasse
Cent Total Heat Equivalent
Extraction Per Heat Required Heat to one
of Cent Per Fuel Per Fuel Per Fuel Developed to Available Pound
Weight Moisture Cent Value, Cent Value, Cent Value, per Evaporate for of Coal of
of in in B. t. in B. t. in B. t. Pound of Moisture Steam 14,000
Cane Bagasse Bagasse u. Bagasse u. Bagasse u. Bagasse [42] Generation B. t. u.
BASED UPON CANE OF 12 PER CENT FIBER AND JUICE CONTAINING 18 PER CENT OF SOLID
MATTER.
REPRESENTING TROPICAL CONDITIONS
75 42.64 48.00 3996 6.24 451 3.12 217 4664 525 4139 3.38
77 39.22 52.17 4343 5.74 414 2.87 200 4958 483 4475 3.13
79 35.15 57.14 4757 5.14 371 2.57 179 5307 433 4874 2.87
81 30.21 63.16 5258 4.42 319 2.21 154 5731 372 5359 2.61
83 24.12 70.59 5877 3.53 256 1.76 122 6255 297 5958 2.35
85 16.20 80.00 6660 2.40 173 1.20 83 6916 200 6716 2.08
BASED UPON CANE OF 10 PER CENT FIBER AND JUICE CONTAINING 15 PER CENT OF SOLID
MATTER.
REPRESENTING LOUISIANA CONDITIONS
75 51.00 40.00 3330 6.00 433 3.00 209 3972 678 3294 4.25
77 48.07 43.45 3617 5.66 409 2.82 196 4222 592 3630 3.86
79 44.52 47.62 3964 5.24 378 2.62 182 4524 548 3976 3.52
81 40.18 52.63 4381 4.73 342 2.36 164 4887 495 4392 3.19
83 35.00 58.82 4897 4.12 298 2.06 143 5436 431 5005 2.80
85 28.33 66.67 5550 3.33 241 1.67 116 5907 349 5558 2.52
Furnace Design and the Combustion of Bagasse —With the advance in sugar manufacture there came, as
described, a decrease in the amount of bagasse available for fuel. As the general efficiency of a plant of this
description is measured by the amount of auxiliary fuel required per ton of cane, the relative importance of the
furnace design for the burning of this fuel is apparent.
In modern practice, under certain conditions of mill operation, and with bagasse of certain physical properties, the
bagasse available from the cane ground will meet the total steam requirements of the plant as a whole; such
conditions prevail, as described, in Java. In the United States, Cuba, Porto Rico and like countries, however,
auxiliary fuel is almost universally a necessity. The amount will vary, depending to a great extent upon the
proportion of fiber in the cane, which varies widely with the locality and with the age at which it is cut, and to a
lesser extent upon the degree of purity of the manufactured sugar, the use of the maceration water and the
efficiency of the mill apparatus as a whole.
[Pg 208]
Page 286
Fig. 27. Babcock & Wilcox Boiler Set with Green Bagasse Furnace
Experience has shown that this fuel may be burned with the best results in large quantities. A given amount of
bagasse burned in one furnace between two boilers will give better results than the same quantity burned in a
number of smaller furnaces. [Pg 209] An objection has been raised against such practice on the grounds that the
necessity of shutting down two boiler units when it is necessary for any reason to take off a furnace, requires a
larger combined boiler capacity to insure continuity of service. As a matter of fact, several small furnaces will cost
considerably more than one large furnace, and the saving in original furnace cost by such an installation, taken in
conjunction with the added efficiency of the larger furnace over the small, will probably more than offset the cost
of additional boiler units for spares.
The essential features in furnace design for this class of fuel are ample combustion space and a length of gas travel
sufficient to enable the gases to be completely burned before the boiler heating surfaces are encountered.
Experience has shown that better results are secured where the fuel is burned on a hearth rather than on grates, the
objection to the latter method being that the air for combustion enters largely around the edges, where the fuel pile
is thinnest. When burned on a hearth the air for combustion is introduced into the furnace through several rows of
tuyeres placed above and symmetrically around the hearth. An arrangement of such tuyeres over a grate, and a
proper manipulation of the ashpit doors, will overcome largely the objection to grates and at the same time enable
other fuel to be burned in the furnace when necessary. This arrangement of grates and tuyeres is probably the better
from a commercially efficient standpoint. Where the air is admitted through tuyeres over the grate or hearth line, it
impinges on the fuel pile as a whole and causes a uniform combustion. Such tuyeres connect with an annular space
in which, where a blast is used, the air pressure is controlled by a blower.
All experience with this class of fuel indicates that the best results are secured with high combustion rates. With a
natural draft in the furnace of, say, three-tenths inch of water, a combustion rate of from 250 to 300 pounds per
square foot of grate surface per hour may be obtained. With a blast of, say, five-tenths inch of water, this rate can
be increased to 450 pounds per square foot of grate surface per hour. These rates apply to bagasse as fired
containing approximately 50 per cent of moisture. It would appear that the most economical results are secured
with a combustion rate of approximately 300 pounds per square foot per hour which, as stated, may be obtained
with natural draft. Where a natural draft is available sufficient to give such a rate, it is in general to be preferred to
a blast.
Fig. 27 shows a typical bagasse furnace with which very satisfactory results have been obtained. The design of this
furnace may be altered to suit the boilers to which it is connected. It may be changed slightly in its proportions and
Experience has shown that this fuel may be burned with the best results in large quantities. A given amount of
bagasse burned in one furnace between two boilers will give better results than the same quantity burned in a
number of smaller furnaces. [Pg 209] An objection has been raised against such practice on the grounds that the
necessity of shutting down two boiler units when it is necessary for any reason to take off a furnace, requires a
larger combined boiler capacity to insure continuity of service. As a matter of fact, several small furnaces will cost
considerably more than one large furnace, and the saving in original furnace cost by such an installation, taken in
conjunction with the added efficiency of the larger furnace over the small, will probably more than offset the cost
of additional boiler units for spares.
The essential features in furnace design for this class of fuel are ample combustion space and a length of gas travel
sufficient to enable the gases to be completely burned before the boiler heating surfaces are encountered.
Experience has shown that better results are secured where the fuel is burned on a hearth rather than on grates, the
objection to the latter method being that the air for combustion enters largely around the edges, where the fuel pile
is thinnest. When burned on a hearth the air for combustion is introduced into the furnace through several rows of
tuyeres placed above and symmetrically around the hearth. An arrangement of such tuyeres over a grate, and a
proper manipulation of the ashpit doors, will overcome largely the objection to grates and at the same time enable
other fuel to be burned in the furnace when necessary. This arrangement of grates and tuyeres is probably the better
from a commercially efficient standpoint. Where the air is admitted through tuyeres over the grate or hearth line, it
impinges on the fuel pile as a whole and causes a uniform combustion. Such tuyeres connect with an annular space
in which, where a blast is used, the air pressure is controlled by a blower.
All experience with this class of fuel indicates that the best results are secured with high combustion rates. With a
natural draft in the furnace of, say, three-tenths inch of water, a combustion rate of from 250 to 300 pounds per
square foot of grate surface per hour may be obtained. With a blast of, say, five-tenths inch of water, this rate can
be increased to 450 pounds per square foot of grate surface per hour. These rates apply to bagasse as fired
containing approximately 50 per cent of moisture. It would appear that the most economical results are secured
with a combustion rate of approximately 300 pounds per square foot per hour which, as stated, may be obtained
with natural draft. Where a natural draft is available sufficient to give such a rate, it is in general to be preferred to
a blast.
Fig. 27 shows a typical bagasse furnace with which very satisfactory results have been obtained. The design of this
furnace may be altered to suit the boilers to which it is connected. It may be changed slightly in its proportions and
Page 287
in certain instances in its position relative to the boiler. The furnace as shown is essentially a bagasse furnace and
may be modified somewhat to accommodate auxiliary fuel.
The fuel is ignited in a pit A on a hearth which is ordinarily elliptical in shape. Air for combustion is admitted
through the tuyeres B connected to an annular space C through which the amount of air is controlled. Above the pit
the furnace widens out to form a combustion space D which has a cylindrical or spherical roof with its top
ordinarily from 11 to 13 feet above the floor. The gases pass from this space horizontally to a second combustion
chamber E from which they are led through arches F to the boiler. The arrangement of such arches is modified to
suit the boiler or boilers with which the furnace is operated. A furnace of such design embodies the essential
features of ample combustion space and long gas travel.
[Pg 210]
The fuel should be fed to the furnace through an opening in the roof above the pit by some mechanical means
which will insure a constant fuel feed and at the same time prevent the inrush of cold air into the furnace.
This class of fuel deposits a considerable quantity of dust, which if not removed promptly will fuse into a hard
glass-like clinker. Ample provision should be made for the removal of such dust from the furnace, the gas ducts
and the boiler setting, and these should be thoroughly cleaned once in 24 hours.
Table 45 gives the results of several tests on Babcock & Wilcox boilers using fuel of this character.
TABLE 45
TESTS OF BABCOCK & WILCOX BOILERS WITH GREEN BAGASSE
Duration of Test Hours 12 10 10 10
Rated Capacity of Boiler Horse Power 319 319 319 319
Grate Surface Square Feet 33 33 16.5 16.5
Draft in Furnace Inches .30 .28 .29 .27
Draft at Damper Inches .47 .45 .46 .48
Blast under Grates Inches … … … .34
Temperature of Exit Gases Degrees F. 536 541 522 547
CO 2 Per Cent 13.8 12.6 11.7 12.8
Flue Gas Analysis {
O
CO
Per Cent
Per Cent
5.9
0.0
7.6
0.0
8.2
0.0
6.9
0.0
Bagasse per Hour as Fired Pounds 4980 4479 5040 5586
Moisture in Bagasse Per Cent 52.39 52.93 51.84 51.71
Dry Bagasse per Hour Pounds 2371 2108 2427 2697
Dry Bagasse per Square Foot
Pounds 71.9 63.9 147.1 163.4
of Grate Surface per Hour
Water per Hour from and at
Pounds 10141 9850 10430 11229
212 Degrees
Per Cent of Rated Capacity
Per Cent 92.1 89.2 94.7 102.0
Developed
Tan Bark —Tan bark, or spent tan, is the fibrous portion of bark remaining after use in the tanning industry. It is
usually very high in its moisture content, a number of samples giving an average of 65 per cent or about two-thirds
of the total weight of the fuel. The weight of the spent tan is about 2.13 times as great as the weight of the bark
ground. In calorific value an average of 10 samples gives 9500 B. t. u. per pound dry. [43] The available heat per
pound as fired, owing to the great percentage of moisture usually found, will be approximately 2700 B. t. u. Since
the weight of the spent tan as fired is 2.13 as great as the weight of the bark as ground at the mill, one pound of
ground bark produces an available heat of approximately 5700 B. t. u. Relative to bituminous coal, a ton of bark is
equivalent to 0.4 ton of coal. An average chemical analysis of the bark is, carbon 51.8 per cent, hydrogen 6.04,
oxygen 40.74, ash 1.42.
may be modified somewhat to accommodate auxiliary fuel.
The fuel is ignited in a pit A on a hearth which is ordinarily elliptical in shape. Air for combustion is admitted
through the tuyeres B connected to an annular space C through which the amount of air is controlled. Above the pit
the furnace widens out to form a combustion space D which has a cylindrical or spherical roof with its top
ordinarily from 11 to 13 feet above the floor. The gases pass from this space horizontally to a second combustion
chamber E from which they are led through arches F to the boiler. The arrangement of such arches is modified to
suit the boiler or boilers with which the furnace is operated. A furnace of such design embodies the essential
features of ample combustion space and long gas travel.
[Pg 210]
The fuel should be fed to the furnace through an opening in the roof above the pit by some mechanical means
which will insure a constant fuel feed and at the same time prevent the inrush of cold air into the furnace.
This class of fuel deposits a considerable quantity of dust, which if not removed promptly will fuse into a hard
glass-like clinker. Ample provision should be made for the removal of such dust from the furnace, the gas ducts
and the boiler setting, and these should be thoroughly cleaned once in 24 hours.
Table 45 gives the results of several tests on Babcock & Wilcox boilers using fuel of this character.
TABLE 45
TESTS OF BABCOCK & WILCOX BOILERS WITH GREEN BAGASSE
Duration of Test Hours 12 10 10 10
Rated Capacity of Boiler Horse Power 319 319 319 319
Grate Surface Square Feet 33 33 16.5 16.5
Draft in Furnace Inches .30 .28 .29 .27
Draft at Damper Inches .47 .45 .46 .48
Blast under Grates Inches … … … .34
Temperature of Exit Gases Degrees F. 536 541 522 547
CO 2 Per Cent 13.8 12.6 11.7 12.8
Flue Gas Analysis {
O
CO
Per Cent
Per Cent
5.9
0.0
7.6
0.0
8.2
0.0
6.9
0.0
Bagasse per Hour as Fired Pounds 4980 4479 5040 5586
Moisture in Bagasse Per Cent 52.39 52.93 51.84 51.71
Dry Bagasse per Hour Pounds 2371 2108 2427 2697
Dry Bagasse per Square Foot
Pounds 71.9 63.9 147.1 163.4
of Grate Surface per Hour
Water per Hour from and at
Pounds 10141 9850 10430 11229
212 Degrees
Per Cent of Rated Capacity
Per Cent 92.1 89.2 94.7 102.0
Developed
Tan Bark —Tan bark, or spent tan, is the fibrous portion of bark remaining after use in the tanning industry. It is
usually very high in its moisture content, a number of samples giving an average of 65 per cent or about two-thirds
of the total weight of the fuel. The weight of the spent tan is about 2.13 times as great as the weight of the bark
ground. In calorific value an average of 10 samples gives 9500 B. t. u. per pound dry. [43] The available heat per
pound as fired, owing to the great percentage of moisture usually found, will be approximately 2700 B. t. u. Since
the weight of the spent tan as fired is 2.13 as great as the weight of the bark as ground at the mill, one pound of
ground bark produces an available heat of approximately 5700 B. t. u. Relative to bituminous coal, a ton of bark is
equivalent to 0.4 ton of coal. An average chemical analysis of the bark is, carbon 51.8 per cent, hydrogen 6.04,
oxygen 40.74, ash 1.42.
Page 288
Tan bark is burned in isolated cases and in general the remarks on burning wet wood fuel apply to its combustion.
The essential features are a large combustion space, large areas of heated brickwork radiating to the fuel bed, and
draft sufficient for [Pg 211] high combustion rates. The ratings obtainable with this class of fuel will not be as high as
with wet wood fuel, because of the heat value and the excessive moisture content. Mr. D. M. Meyers found in a
series of experiments that an average of from 1.5 to 2.08 horse power could be developed per square foot of grate
surface with horizontal return tubular boilers. This horse power would vary considerably with the method in which
the spent tan was fired.
686 Horse-power Babcock & Wilcox Boiler and Superheater in Course of Erection at the Quincy, Mass.,
Station of the Bay State Street Railway Co.
FOOTNOTES
[40] B. t. u. calculated.
[41] Average of two samples.
[42] Assuming bagasse temperature = 80 degrees Fahrenheit and exit gas temperature = 500 degrees Fahrenheit.
[43] Dr. Henry C. Sherman. Columbia University.
The essential features are a large combustion space, large areas of heated brickwork radiating to the fuel bed, and
draft sufficient for [Pg 211] high combustion rates. The ratings obtainable with this class of fuel will not be as high as
with wet wood fuel, because of the heat value and the excessive moisture content. Mr. D. M. Meyers found in a
series of experiments that an average of from 1.5 to 2.08 horse power could be developed per square foot of grate
surface with horizontal return tubular boilers. This horse power would vary considerably with the method in which
the spent tan was fired.
686 Horse-power Babcock & Wilcox Boiler and Superheater in Course of Erection at the Quincy, Mass.,
Station of the Bay State Street Railway Co.
FOOTNOTES
[40] B. t. u. calculated.
[41] Average of two samples.
[42] Assuming bagasse temperature = 80 degrees Fahrenheit and exit gas temperature = 500 degrees Fahrenheit.
[43] Dr. Henry C. Sherman. Columbia University.
Page 289
[Pg 212]
Page 290
LIQUID FUELS AND THEIR COMBUSTION
Petroleum is practically the only liquid fuel sufficiently abundant and cheap to be
used for the generation of steam. It possesses many advantages over coal and is
extensively used in many localities.
There are three kinds of petroleum in use, namely those yielding on distillation: 1st,
paraffin; 2nd, asphalt; 3rd, olefine. To the first group belong the oils of the
Appalachian Range and the Middle West of the United States. These are a dark brown
in color with a greenish tinge. Upon their distillation such a variety of valuable light
oils are obtained that their use as fuel is prohibitive because of price.
To the second group belong the oils found in Texas and California. These vary in
color from a reddish brown to a jet black and are used very largely as fuel.
The third group comprises the oils from Russia, which, like the second, are used
largely for fuel purposes.
The light and easily ignited constituents of petroleum, such as naphtha, gasolene and
kerosene, are oftentimes driven off by a partial distillation, these products being of
greater value for other purposes than for use as fuel. This partial distillation does not
decrease the value of petroleum as a fuel; in fact, the residuum known in trade as
“fuel oil” has a slightly higher calorific value than petroleum and because of its
higher flash point, it may be more safely handled. Statements made with reference to
petroleum apply as well to fuel oil.
In general crude oil consists of carbon and hydrogen, though it also contains varying
quantities of moisture, sulphur, nitrogen, arsenic, phosphorus and silt. The moisture
contained may vary from less than 1 to over 30 per cent, depending upon the care
taken to separate the water from the oil in pumping from the well. As in any fuel, this
moisture affects the available heat of the oil, and in contracting for the purchase of
fuel of this nature it is well to limit the per cent of moisture it may contain. A large
portion of any contained moisture can be separated by settling and for this reason
sufficient storage capacity should be supplied to provide time for such action.
A method of obtaining approximately the percentage of moisture in crude oil which
may be used successfully, particularly with lighter oils, is as follows. A burette
graduated into 200 divisions is filled to the 100 mark with gasolene, and the
remaining 100 divisions with the oil, which should be slightly warmed before mixing.
The two are then shaken together and any shrinkage below the 200 mark filled up
Petroleum is practically the only liquid fuel sufficiently abundant and cheap to be
used for the generation of steam. It possesses many advantages over coal and is
extensively used in many localities.
There are three kinds of petroleum in use, namely those yielding on distillation: 1st,
paraffin; 2nd, asphalt; 3rd, olefine. To the first group belong the oils of the
Appalachian Range and the Middle West of the United States. These are a dark brown
in color with a greenish tinge. Upon their distillation such a variety of valuable light
oils are obtained that their use as fuel is prohibitive because of price.
To the second group belong the oils found in Texas and California. These vary in
color from a reddish brown to a jet black and are used very largely as fuel.
The third group comprises the oils from Russia, which, like the second, are used
largely for fuel purposes.
The light and easily ignited constituents of petroleum, such as naphtha, gasolene and
kerosene, are oftentimes driven off by a partial distillation, these products being of
greater value for other purposes than for use as fuel. This partial distillation does not
decrease the value of petroleum as a fuel; in fact, the residuum known in trade as
“fuel oil” has a slightly higher calorific value than petroleum and because of its
higher flash point, it may be more safely handled. Statements made with reference to
petroleum apply as well to fuel oil.
In general crude oil consists of carbon and hydrogen, though it also contains varying
quantities of moisture, sulphur, nitrogen, arsenic, phosphorus and silt. The moisture
contained may vary from less than 1 to over 30 per cent, depending upon the care
taken to separate the water from the oil in pumping from the well. As in any fuel, this
moisture affects the available heat of the oil, and in contracting for the purchase of
fuel of this nature it is well to limit the per cent of moisture it may contain. A large
portion of any contained moisture can be separated by settling and for this reason
sufficient storage capacity should be supplied to provide time for such action.
A method of obtaining approximately the percentage of moisture in crude oil which
may be used successfully, particularly with lighter oils, is as follows. A burette
graduated into 200 divisions is filled to the 100 mark with gasolene, and the
remaining 100 divisions with the oil, which should be slightly warmed before mixing.
The two are then shaken together and any shrinkage below the 200 mark filled up
Page 291
with oil. The mixture should then be allowed to stand in a warm place for 24 hours,
during which the water and silt will settle to the bottom. Their percentage by volume
can then be correctly read on the burette divisions, and the percentage by weight
calculated from the specific gravities. This method is exceedingly approximate and
where accurate results are required it should not be used. For such work, the
distillation method should be used as follows:
Gradually heat 100 cubic centimeters of the oil in a distillation flask to a temperature
of 150 degrees centigrade; collect the distillate in a graduated tube and measure the
resulting water. Such a method insures complete removal of water and reduces the
error arising from the slight solubility of the water in [Pg 213] gasolene. Two samples
checked by the two methods for the amount of moisture present gave,
TABLE 46
COMPOSITION AND CALORIFIC VALUE OF VARIOUS OILS
Per Per Degrees B. t. u.
Per Cent Per Cent Specific Per Cent
Kind of Oil Cent Cent Flash Per Authority
Hydrogen Oxygen Gravity Moisture
Carbon Sulphur Point Pound
California, Babcock &
.927 134 17117
Coaling Wilcox Co.
California,
.975 17600 Wade
Bakersfield
California,
1.30 .992 18257 Wade
Bakersfield
California, Babcock &
.950 140 18845
Kern River Wilcox Co.
California, Los Babcock &
2.56 18328
Angeles Wilcox Co.
California, Los Babcock &
.957 196 18855
Angeles Wilcox Co.
California, Los Babcock &
.977 .40 18280
Angeles Wilcox Co.
California, Babcock &
.966 205 18878
Monte Christo Wilcox Co.
California,
.98 .944 1.06 18507 Wade
Whittier
California,
.72 .936 1.06 18240 Wade
Whittier
Babcock &
California 85.04 11.52 2.45 .99[44] 1.40 17871
Wilcox Co.
during which the water and silt will settle to the bottom. Their percentage by volume
can then be correctly read on the burette divisions, and the percentage by weight
calculated from the specific gravities. This method is exceedingly approximate and
where accurate results are required it should not be used. For such work, the
distillation method should be used as follows:
Gradually heat 100 cubic centimeters of the oil in a distillation flask to a temperature
of 150 degrees centigrade; collect the distillate in a graduated tube and measure the
resulting water. Such a method insures complete removal of water and reduces the
error arising from the slight solubility of the water in [Pg 213] gasolene. Two samples
checked by the two methods for the amount of moisture present gave,
TABLE 46
COMPOSITION AND CALORIFIC VALUE OF VARIOUS OILS
Per Per Degrees B. t. u.
Per Cent Per Cent Specific Per Cent
Kind of Oil Cent Cent Flash Per Authority
Hydrogen Oxygen Gravity Moisture
Carbon Sulphur Point Pound
California, Babcock &
.927 134 17117
Coaling Wilcox Co.
California,
.975 17600 Wade
Bakersfield
California,
1.30 .992 18257 Wade
Bakersfield
California, Babcock &
.950 140 18845
Kern River Wilcox Co.
California, Los Babcock &
2.56 18328
Angeles Wilcox Co.
California, Los Babcock &
.957 196 18855
Angeles Wilcox Co.
California, Los Babcock &
.977 .40 18280
Angeles Wilcox Co.
California, Babcock &
.966 205 18878
Monte Christo Wilcox Co.
California,
.98 .944 1.06 18507 Wade
Whittier
California,
.72 .936 1.06 18240 Wade
Whittier
Babcock &
California 85.04 11.52 2.45 .99[44] 1.40 17871
Wilcox Co.
Page 292
U. S. N.
California 81.52 11.51 .55 6.92[44] 230 18667 Liquid Fuel
Board
California .87 .95 18533 Blasdale
Babcock &
California .891 257 18655
Wilcox Co.
California 2.45 .973 1.50[45] 17976 O’Neill
California 2.46 .975 1.32 18104 Shepherd
U. S. N.
Texas,
84.6 10.9 1.63 2.87 .924 180 19060 Liquid Fuel
Beaumont
Board
U. S. N.
Texas,
83.3 12.4 .50 3.83 .926 216 19481 Liquid Fuel
Beaumont
Board
Texas,
85.0 12.3 1.75 .92[44] 19060 Denton
Beaumont
Texas,
86.1 12.3 1.60 .942 20152 Sparkes
Beaumont
Texas, Babcock &
.903 222 19349
Beaumont Wilcox Co.
Babcock &
Texas, Sabine .937 143 18662
Wilcox Co.
Texas 87.15 12.33 0.32 .908 370 19338 U. S. N.
Texas 87.29 12.32 0.43 .910 375 19659 U. S. N.
Ohio 83.4 14.7 0.6 1.3 19580
Pennsylvania 84.9 13.7 1.4 .886 19210 Booth
West Virginia 84.3 14.1 1.6 .841 21240
Babcock &
Mexico .921 162 18840
Wilcox Co.
Russia, Baku 86.7 12.9 .884 20691 Booth
Russia,
84.9 11.6 3.46 19452 Booth
Novorossick
Russia,
86.6 12.3 1.10 .938 20138
Caucasus
Java 87.1 12.0 .9 .923 21163
Austria,
82.2 12.1 5.7 .870 18416
Galicia
Italy, Parma 84.0 13.4 1.8 .786
Borneo 85.7 11.0 3.31 19240 Orde
California 81.52 11.51 .55 6.92[44] 230 18667 Liquid Fuel
Board
California .87 .95 18533 Blasdale
Babcock &
California .891 257 18655
Wilcox Co.
California 2.45 .973 1.50[45] 17976 O’Neill
California 2.46 .975 1.32 18104 Shepherd
U. S. N.
Texas,
84.6 10.9 1.63 2.87 .924 180 19060 Liquid Fuel
Beaumont
Board
U. S. N.
Texas,
83.3 12.4 .50 3.83 .926 216 19481 Liquid Fuel
Beaumont
Board
Texas,
85.0 12.3 1.75 .92[44] 19060 Denton
Beaumont
Texas,
86.1 12.3 1.60 .942 20152 Sparkes
Beaumont
Texas, Babcock &
.903 222 19349
Beaumont Wilcox Co.
Babcock &
Texas, Sabine .937 143 18662
Wilcox Co.
Texas 87.15 12.33 0.32 .908 370 19338 U. S. N.
Texas 87.29 12.32 0.43 .910 375 19659 U. S. N.
Ohio 83.4 14.7 0.6 1.3 19580
Pennsylvania 84.9 13.7 1.4 .886 19210 Booth
West Virginia 84.3 14.1 1.6 .841 21240
Babcock &
Mexico .921 162 18840
Wilcox Co.
Russia, Baku 86.7 12.9 .884 20691 Booth
Russia,
84.9 11.6 3.46 19452 Booth
Novorossick
Russia,
86.6 12.3 1.10 .938 20138
Caucasus
Java 87.1 12.0 .9 .923 21163
Austria,
82.2 12.1 5.7 .870 18416
Galicia
Italy, Parma 84.0 13.4 1.8 .786
Borneo 85.7 11.0 3.31 19240 Orde
Page 293
Calorific Value—A pound of petroleum usually has a calorific value of from 18,000
to 22,000 B. t. u. If an ultimate analysis of an average sample be, carbon 84 per cent,
hydrogen 14 per cent, oxygen 2 per cent, and assuming that the oxygen is [Pg 214]
combined with its equivalent of hydrogen as water, the analysis would become,
carbon 84 per cent, hydrogen 13.75 per cent, water 2.25 per cent, and the heat value
per pound including its contained water would be,
Carbon .8400 × 14,600 = 12,264 B. t. u.
Hydrogen .1375 × 62,000 = 8,525 B. t. u.
–––––––––––
Total 20,789 B. t. u.
The nitrogen in petroleum varies from 0.008 to 1.0 per cent, while the sulphur varies
from 0.07 to 3.0 per cent.
Table 46, compiled from various sources, gives the composition, calorific value and
other data relative to oil from different localities.
The flash point of crude oil is the temperature at which it gives off inflammable gases.
While information on the actual flash points of the various oils is meager, it is,
nevertheless, a question of importance in determining their availability as fuels. In
general it may be stated that the light oils have a low, and the heavy oils a much
higher flash point. A division is sometimes made at oils having a specific gravity of
0.85, with a statement that where the specific gravity is below this point the flash
point is below 60 degrees Fahrenheit, and where it is above, the flash point is above
60 degrees Fahrenheit. There are, however, many exceptions to this rule. As the flash
point is lower the danger of ignition or explosion becomes greater, and the utmost
care should be taken in handling the oils with a low flash point to avoid this danger.
On the other hand, because the flash point is high is no justification for carelessness
in handling those fuels. With proper precautions taken, in general, the use of oil as
fuel is practically as safe as the use of coal.
Gravity of Oils—Oils are frequently classified according to their gravity as indicated
by the Beaume hydrometer scale. Such a classification is by no means an accurate
measure of their relative calorific values.
Petroleum as Compared with Coal—The advantages of the use of oil fuel over coal
may be summarized as follows:
1st. The cost of handling is much lower, the oil being fed by simple mechanical
means, resulting in,
to 22,000 B. t. u. If an ultimate analysis of an average sample be, carbon 84 per cent,
hydrogen 14 per cent, oxygen 2 per cent, and assuming that the oxygen is [Pg 214]
combined with its equivalent of hydrogen as water, the analysis would become,
carbon 84 per cent, hydrogen 13.75 per cent, water 2.25 per cent, and the heat value
per pound including its contained water would be,
Carbon .8400 × 14,600 = 12,264 B. t. u.
Hydrogen .1375 × 62,000 = 8,525 B. t. u.
–––––––––––
Total 20,789 B. t. u.
The nitrogen in petroleum varies from 0.008 to 1.0 per cent, while the sulphur varies
from 0.07 to 3.0 per cent.
Table 46, compiled from various sources, gives the composition, calorific value and
other data relative to oil from different localities.
The flash point of crude oil is the temperature at which it gives off inflammable gases.
While information on the actual flash points of the various oils is meager, it is,
nevertheless, a question of importance in determining their availability as fuels. In
general it may be stated that the light oils have a low, and the heavy oils a much
higher flash point. A division is sometimes made at oils having a specific gravity of
0.85, with a statement that where the specific gravity is below this point the flash
point is below 60 degrees Fahrenheit, and where it is above, the flash point is above
60 degrees Fahrenheit. There are, however, many exceptions to this rule. As the flash
point is lower the danger of ignition or explosion becomes greater, and the utmost
care should be taken in handling the oils with a low flash point to avoid this danger.
On the other hand, because the flash point is high is no justification for carelessness
in handling those fuels. With proper precautions taken, in general, the use of oil as
fuel is practically as safe as the use of coal.
Gravity of Oils—Oils are frequently classified according to their gravity as indicated
by the Beaume hydrometer scale. Such a classification is by no means an accurate
measure of their relative calorific values.
Petroleum as Compared with Coal—The advantages of the use of oil fuel over coal
may be summarized as follows:
1st. The cost of handling is much lower, the oil being fed by simple mechanical
means, resulting in,
Page 294
2nd. A general labor saving throughout the plant in the elimination of stokers, coal
passers, ash handlers, etc.
3rd. For equal heat value, oil occupies very much less space than coal. This storage
space may be at a distance from the boiler without detriment.
4th. Higher efficiencies and capacities are obtainable with oil than with coal. The
combustion is more perfect as the excess air is reduced to a minimum; the furnace
temperature may be kept practically constant as the furnace doors need not be opened
for cleaning or working fires; smoke may be eliminated with the consequent
increased cleanliness of the heating surfaces.
5th. The intensity of the fire can be almost instantaneously regulated to meet load
fluctuations.
6th. Oil when stored does not lose in calorific value as does coal, nor are there any
difficulties arising from disintegration, such as may be found when coal is stored.
7th. Cleanliness and freedom from dust and ashes in the boiler room with a
consequent saving in wear and tear on machinery; little or no damage to surrounding
property due to such dust.
[Pg 215]
The disadvantages of oil are:
1st. The necessity that the oil have a reasonably high flash point to minimize the
danger of explosions.
2nd. City or town ordinances may impose burdensome conditions relative to location
and isolation of storage tanks, which in the case of a plant situated in a congested
portion of the city, might make use of this fuel prohibitive.
3rd. Unless the boilers and furnaces are especially adapted for the use of this fuel, the
boiler upkeep cost will be higher than if coal were used. This objection can be entirely
obviated, however, if the installation is entrusted to those who have had experience in
the work, and the operation of a properly designed plant is placed in the hands of
intelligent labor.
TABLE 47
RELATIVE VALUE OF COAL AND OIL FUEL
passers, ash handlers, etc.
3rd. For equal heat value, oil occupies very much less space than coal. This storage
space may be at a distance from the boiler without detriment.
4th. Higher efficiencies and capacities are obtainable with oil than with coal. The
combustion is more perfect as the excess air is reduced to a minimum; the furnace
temperature may be kept practically constant as the furnace doors need not be opened
for cleaning or working fires; smoke may be eliminated with the consequent
increased cleanliness of the heating surfaces.
5th. The intensity of the fire can be almost instantaneously regulated to meet load
fluctuations.
6th. Oil when stored does not lose in calorific value as does coal, nor are there any
difficulties arising from disintegration, such as may be found when coal is stored.
7th. Cleanliness and freedom from dust and ashes in the boiler room with a
consequent saving in wear and tear on machinery; little or no damage to surrounding
property due to such dust.
[Pg 215]
The disadvantages of oil are:
1st. The necessity that the oil have a reasonably high flash point to minimize the
danger of explosions.
2nd. City or town ordinances may impose burdensome conditions relative to location
and isolation of storage tanks, which in the case of a plant situated in a congested
portion of the city, might make use of this fuel prohibitive.
3rd. Unless the boilers and furnaces are especially adapted for the use of this fuel, the
boiler upkeep cost will be higher than if coal were used. This objection can be entirely
obviated, however, if the installation is entrusted to those who have had experience in
the work, and the operation of a properly designed plant is placed in the hands of
intelligent labor.
TABLE 47
RELATIVE VALUE OF COAL AND OIL FUEL
Page 295
Net
Evaporation Water Evaporated from and at
Gross Net
from and at 212 Degrees Fahrenheit per Pound of Coal
Boiler Boiler
212
Efficiency Efficiency[46]
Degrees 5 6 7 8 9 10 11 12
with Oil with Oil
Fahrenheit
Fuel Fuel
per Pound
Pounds of Oil Equal to One Pound of Coal
of Oil
73 71 13.54 .3693 .4431 .5170.5909.6647.7386 .8124.8863
74 72 13.73 .3642 .4370 .5099.5827.6556.7283 .8011 .8740
75 73 13.92 .3592 .4310 .5029.5747.6466.7184 .7903.8621
76 74 14.11 .3544 .4253 .4961.5670.6378.7087 .7796.8505
77 75 14.30 .3497 .4196 .4895.5594.6294.6993 .7692.8392
78 76 14.49 .3451 .4141 .4831.5521 .6211 .6901 .7591.8281
79 77 14.68 .3406 .4087 .4768.5450.6131.6812 .7493.8174
80 78 14.87 .3363 .4035 .4708.5380.6053.6725 .7398.8070
81 79 15.06 .3320 .3984 .4648.5312.5976.6640 .7304.7968
82 80 15.25 .3279 .3934 .4590.5246.5902.6557 .7213.7869
83 81 15.44 .3238 .3886 .4534.5181.5829.6447 .7125.7772
Net
Evaporation
from and at
212
Barrels of Oil Equal to One Ton of Coal
Degrees
Fahrenheit
per Barrel
of Oil
73 71 4549 2.198 2.638 3.0773.5163.9554.395 4.8355.275
74 72 4613 2.168 2.601 3.0353.4683.9024.335 4.7695.202
75 73 4677 2.138 2.565 2.9933.4203.8484.275 4.7035.131
76 74 4741 2.110 2.532 2.9543.3763.7984.220 4.6425.063
77 75 4807 2.082 2.498 2.9143.3303.7464.162 4.5784.994
78 76 4869 2.054 2.465 2.8763.2863.6974.108 4.5184.929
79 77 4932 2.027 2.433 2.8383.2433.6494.054 4.4604.865
80 78 4996 2.002 2.402 2.8023.2023.6024.003 4.4034.803
81 79 5060 1.976 2.371 2.7673.1623.5573.952 4.3484.743
82 80 5124 1.952 2.342 2.7323.1223.5133.903 4.2934.683
83 81 5187 1.927 2.313 2.6993.0853.4703.856 4.2414.627
Evaporation Water Evaporated from and at
Gross Net
from and at 212 Degrees Fahrenheit per Pound of Coal
Boiler Boiler
212
Efficiency Efficiency[46]
Degrees 5 6 7 8 9 10 11 12
with Oil with Oil
Fahrenheit
Fuel Fuel
per Pound
Pounds of Oil Equal to One Pound of Coal
of Oil
73 71 13.54 .3693 .4431 .5170.5909.6647.7386 .8124.8863
74 72 13.73 .3642 .4370 .5099.5827.6556.7283 .8011 .8740
75 73 13.92 .3592 .4310 .5029.5747.6466.7184 .7903.8621
76 74 14.11 .3544 .4253 .4961.5670.6378.7087 .7796.8505
77 75 14.30 .3497 .4196 .4895.5594.6294.6993 .7692.8392
78 76 14.49 .3451 .4141 .4831.5521 .6211 .6901 .7591.8281
79 77 14.68 .3406 .4087 .4768.5450.6131.6812 .7493.8174
80 78 14.87 .3363 .4035 .4708.5380.6053.6725 .7398.8070
81 79 15.06 .3320 .3984 .4648.5312.5976.6640 .7304.7968
82 80 15.25 .3279 .3934 .4590.5246.5902.6557 .7213.7869
83 81 15.44 .3238 .3886 .4534.5181.5829.6447 .7125.7772
Net
Evaporation
from and at
212
Barrels of Oil Equal to One Ton of Coal
Degrees
Fahrenheit
per Barrel
of Oil
73 71 4549 2.198 2.638 3.0773.5163.9554.395 4.8355.275
74 72 4613 2.168 2.601 3.0353.4683.9024.335 4.7695.202
75 73 4677 2.138 2.565 2.9933.4203.8484.275 4.7035.131
76 74 4741 2.110 2.532 2.9543.3763.7984.220 4.6425.063
77 75 4807 2.082 2.498 2.9143.3303.7464.162 4.5784.994
78 76 4869 2.054 2.465 2.8763.2863.6974.108 4.5184.929
79 77 4932 2.027 2.433 2.8383.2433.6494.054 4.4604.865
80 78 4996 2.002 2.402 2.8023.2023.6024.003 4.4034.803
81 79 5060 1.976 2.371 2.7673.1623.5573.952 4.3484.743
82 80 5124 1.952 2.342 2.7323.1223.5133.903 4.2934.683
83 81 5187 1.927 2.313 2.6993.0853.4703.856 4.2414.627
Page 296
Many tables have been published with a view to comparing the two fuels. Such of
these as are based solely on the relative calorific values of oil and coal are of limited
[Pg 216]
[Pg 217] value, inasmuch as the efficiencies to be obtained with oil are higher than that
obtainable with coal. Table 47 takes into consideration the variation in efficiency with
the two fuels, but is based on a constant calorific value for oil and coal. This table,
like others of a similar nature, while useful as a rough guide, cannot be considered as
an accurate basis for comparison. This is due to the fact that there are numerous
factors entering into the problem which affect the saving possible to a much greater
extent than do the relative calorific values of two fuels. Some of the features to be
considered in arriving at the true basis for comparison are the labor saving possible,
the space available for fuel storage, the facilities for conveying the oil by pipe lines,
the hours during which a plant is in operation, the load factor, the quantity of coal
required for banking fires, etc., etc. The only exact method of estimating the relative
advantages and costs of the two fuels is by considering the operating expenses of the
plant with each in turn, including the costs of every item entering into the problem.
City of San Francisco, Cal., Fire Fighting Station. No. 1. 2800 Horse Power of
Babcock & Wilcox Boilers, Equipped for Burning Oil Fuel
Burning Oil Fuel—The requirements for burning petroleum are as follows:
1st. Its atomization must be thorough.
these as are based solely on the relative calorific values of oil and coal are of limited
[Pg 216]
[Pg 217] value, inasmuch as the efficiencies to be obtained with oil are higher than that
obtainable with coal. Table 47 takes into consideration the variation in efficiency with
the two fuels, but is based on a constant calorific value for oil and coal. This table,
like others of a similar nature, while useful as a rough guide, cannot be considered as
an accurate basis for comparison. This is due to the fact that there are numerous
factors entering into the problem which affect the saving possible to a much greater
extent than do the relative calorific values of two fuels. Some of the features to be
considered in arriving at the true basis for comparison are the labor saving possible,
the space available for fuel storage, the facilities for conveying the oil by pipe lines,
the hours during which a plant is in operation, the load factor, the quantity of coal
required for banking fires, etc., etc. The only exact method of estimating the relative
advantages and costs of the two fuels is by considering the operating expenses of the
plant with each in turn, including the costs of every item entering into the problem.
City of San Francisco, Cal., Fire Fighting Station. No. 1. 2800 Horse Power of
Babcock & Wilcox Boilers, Equipped for Burning Oil Fuel
Burning Oil Fuel—The requirements for burning petroleum are as follows:
1st. Its atomization must be thorough.
Page 297
2nd. When atomized it must be brought into contact with the requisite quantity of air
for its combustion, and this quantity must be at the same time a minimum to obviate
loss in stack gases.
3rd. The mixture must be burned in a furnace where a refractory material radiates heat
to assist in the combustion, and the furnace must stand up under the high temperatures
developed.
4th. The combustion must be completed before the gases come into contact with the
heating surfaces or otherwise the flame will be extinguished, possibly to ignite later in
the flue connection or in the stack.
5th. There must be no localization of the heat on certain portions of the heating
surfaces or trouble will result from overheating and blistering.
The first requirement is met by the selection of a proper burner.
The second requirement is fulfilled by properly introducing the air into the furnace,
either through checkerwork under the burners or through openings around them, and
by controlling the quantity of air to meet variations in furnace conditions.
The third requirement is provided for by installing a furnace so designed as to give a
sufficient area of heated brickwork to radiate the heat required to maintain a proper
furnace temperature.
The fourth requirement is provided for by giving ample space for the combustion of
the mixture of atomized oil and air, and a gas travel of sufficient length to insure that
this combustion be completed before the gases strike the heating surfaces.
The fifth requirement is fulfilled by the adoption of a suitable burner in connection
with the furnace meeting the other requirements. A burner must be used from which
the flame will not impinge directly on the heating surface and must be located where
such action cannot take place. If suitable burners properly located are not used, not
only is the heat localized with disastrous results, but the efficiency is lowered by the
cooling of the gases before combustion is completed.
Oil Burners—The functions of an oil burner is to atomize or vaporize the fuel so that
it may be burned like a gas. All burners may be classified under three general types:
1st, spray burners, in which the oil is atomized by steam or compressed air; 2nd,
vapor burners, in which the oil is converted into vapor and then passed into the [Pg 218]
furnace; 3rd, mechanical burners, in which the oil is atomized by submitting it to a
high pressure and passing it through a small orifice.
for its combustion, and this quantity must be at the same time a minimum to obviate
loss in stack gases.
3rd. The mixture must be burned in a furnace where a refractory material radiates heat
to assist in the combustion, and the furnace must stand up under the high temperatures
developed.
4th. The combustion must be completed before the gases come into contact with the
heating surfaces or otherwise the flame will be extinguished, possibly to ignite later in
the flue connection or in the stack.
5th. There must be no localization of the heat on certain portions of the heating
surfaces or trouble will result from overheating and blistering.
The first requirement is met by the selection of a proper burner.
The second requirement is fulfilled by properly introducing the air into the furnace,
either through checkerwork under the burners or through openings around them, and
by controlling the quantity of air to meet variations in furnace conditions.
The third requirement is provided for by installing a furnace so designed as to give a
sufficient area of heated brickwork to radiate the heat required to maintain a proper
furnace temperature.
The fourth requirement is provided for by giving ample space for the combustion of
the mixture of atomized oil and air, and a gas travel of sufficient length to insure that
this combustion be completed before the gases strike the heating surfaces.
The fifth requirement is fulfilled by the adoption of a suitable burner in connection
with the furnace meeting the other requirements. A burner must be used from which
the flame will not impinge directly on the heating surface and must be located where
such action cannot take place. If suitable burners properly located are not used, not
only is the heat localized with disastrous results, but the efficiency is lowered by the
cooling of the gases before combustion is completed.
Oil Burners—The functions of an oil burner is to atomize or vaporize the fuel so that
it may be burned like a gas. All burners may be classified under three general types:
1st, spray burners, in which the oil is atomized by steam or compressed air; 2nd,
vapor burners, in which the oil is converted into vapor and then passed into the [Pg 218]
furnace; 3rd, mechanical burners, in which the oil is atomized by submitting it to a
high pressure and passing it through a small orifice.
Page 298
Vapor burners have never been in general use and will not be discussed.
Spray burners are almost universally used for land practice and the simplicity of the
steam atomizer and the excellent economy of the better types, together with the low
oil pressure and temperature required makes this type a favorite for stationary plants,
where the loss of fresh water is not a vital consideration. In marine work, or in any
case where it is advisable to save feed water that otherwise would have to be added in
the form of “make-up”, either compressed air or mechanical means are used for
atomization. Spray burners using compressed air as the atomizing agent are in
satisfactory operation in some plants, but their use is not general. Where there is no
necessity of saving raw feed water, the greater simplicity and economy of the steam
spray atomizer is generally the most satisfactory. The air burners require blowers,
compressors or other apparatus which occupy space that might be otherwise utilized
and require attention that is not necessary where steam is used.
Steam spray burners of the older types had disadvantages in that they were so
designed that there was a tendency for the nozzle to clog with sludge or coke formed
from the oil by the heat, without means of being readily cleaned. This has been
overcome in the more modern types.
Steam spray burners, as now used, may be divided into two classes: 1st, inside
mixers; and 2nd, outside mixers. In the former the steam and oil come into contact
within the burner and the mixture is atomized in passing through the orifice of the
burner nozzle.
Fig. 28. Peabody Oil Burner
In the outside mixing class the steam flows through a narrow slot or horizontal row of
small holes in the burner nozzle; the oil flows through a similar slot or hole above the
steam orifice, and is picked up by the steam outside of the burner and is atomized.
Spray burners are almost universally used for land practice and the simplicity of the
steam atomizer and the excellent economy of the better types, together with the low
oil pressure and temperature required makes this type a favorite for stationary plants,
where the loss of fresh water is not a vital consideration. In marine work, or in any
case where it is advisable to save feed water that otherwise would have to be added in
the form of “make-up”, either compressed air or mechanical means are used for
atomization. Spray burners using compressed air as the atomizing agent are in
satisfactory operation in some plants, but their use is not general. Where there is no
necessity of saving raw feed water, the greater simplicity and economy of the steam
spray atomizer is generally the most satisfactory. The air burners require blowers,
compressors or other apparatus which occupy space that might be otherwise utilized
and require attention that is not necessary where steam is used.
Steam spray burners of the older types had disadvantages in that they were so
designed that there was a tendency for the nozzle to clog with sludge or coke formed
from the oil by the heat, without means of being readily cleaned. This has been
overcome in the more modern types.
Steam spray burners, as now used, may be divided into two classes: 1st, inside
mixers; and 2nd, outside mixers. In the former the steam and oil come into contact
within the burner and the mixture is atomized in passing through the orifice of the
burner nozzle.
Fig. 28. Peabody Oil Burner
In the outside mixing class the steam flows through a narrow slot or horizontal row of
small holes in the burner nozzle; the oil flows through a similar slot or hole above the
steam orifice, and is picked up by the steam outside of the burner and is atomized.
Page 299
Fig. 28 shows a type of the Peabody burner of this class, which has [Pg 219] given
eminent satisfaction. The construction is evident from the cut. It will be noted that the
portions of the burner forming the orifice may be readily replaced in case of wear, or
if it is desired to alter the form of the flame.
Where burners of the spray type are used, heating the oil is of advantage not only in
causing it to be atomized more easily, but in aiding economical combustion. The
temperature is, of course, limited by the flash point of the oil used, but within the
limit of this temperature there is no danger of decomposition or of carbon deposits on
the supply pipes. Such heating should be done close to the boiler to minimize
radiation loss. If the temperature is raised to a point where an appreciable
vaporization occurs, the oil will flow irregularly from the burner and cause the flame
to sputter.
On both steam and air atomizing types, a by-pass should be installed between the
steam or air and the oil pipes to provide for the blowing out of the oil duct. Strainers
should be provided for removing sludge from the fuel and should be so located as to
allow for rapid removal, cleaning and replacing.
Mechanical burners have been in use for some time in European countries, but their
introduction and use has been of only recent occurrence in the United States. Here as
already stated, the means for atomization are purely mechanical. The most successful
of the mechanical atomizers up to the present have been of the round flame type, and
only these will be considered. Experiments have been made with flat flame
mechanical burners, but their satisfactory action has been confined to instances where
it is only necessary to burn a small quantity of oil through each individual burner.
This system of oil burning is especially adapted for marine work as the quantity of
steam for putting pressure on the oil is small and the condensed steam may be
returned to the system.
The only method by which successful mechanical atomization has been accomplished
is one by which the oil is given a whirling motion within the burner tip. This is done
either by forcing the oil through a passage of helical form or by delivering it
tangentially to a circular chamber from which there is a central outlet. The oil is fed to
these burners under a pressure which varies with the make of the burner and the rates
at which individual burners are using oil. The oil particles fly off from such a burner
in straight lines in the form of a cone rather than in the form of a spiral spray, as
might be supposed.
With burners of the mechanical atomizing design, the method of introducing air for
combustion and the velocity of this air are of the greatest importance in securing good
combustion and in the effects on the character and shape of the flame. Such burners
eminent satisfaction. The construction is evident from the cut. It will be noted that the
portions of the burner forming the orifice may be readily replaced in case of wear, or
if it is desired to alter the form of the flame.
Where burners of the spray type are used, heating the oil is of advantage not only in
causing it to be atomized more easily, but in aiding economical combustion. The
temperature is, of course, limited by the flash point of the oil used, but within the
limit of this temperature there is no danger of decomposition or of carbon deposits on
the supply pipes. Such heating should be done close to the boiler to minimize
radiation loss. If the temperature is raised to a point where an appreciable
vaporization occurs, the oil will flow irregularly from the burner and cause the flame
to sputter.
On both steam and air atomizing types, a by-pass should be installed between the
steam or air and the oil pipes to provide for the blowing out of the oil duct. Strainers
should be provided for removing sludge from the fuel and should be so located as to
allow for rapid removal, cleaning and replacing.
Mechanical burners have been in use for some time in European countries, but their
introduction and use has been of only recent occurrence in the United States. Here as
already stated, the means for atomization are purely mechanical. The most successful
of the mechanical atomizers up to the present have been of the round flame type, and
only these will be considered. Experiments have been made with flat flame
mechanical burners, but their satisfactory action has been confined to instances where
it is only necessary to burn a small quantity of oil through each individual burner.
This system of oil burning is especially adapted for marine work as the quantity of
steam for putting pressure on the oil is small and the condensed steam may be
returned to the system.
The only method by which successful mechanical atomization has been accomplished
is one by which the oil is given a whirling motion within the burner tip. This is done
either by forcing the oil through a passage of helical form or by delivering it
tangentially to a circular chamber from which there is a central outlet. The oil is fed to
these burners under a pressure which varies with the make of the burner and the rates
at which individual burners are using oil. The oil particles fly off from such a burner
in straight lines in the form of a cone rather than in the form of a spiral spray, as
might be supposed.
With burners of the mechanical atomizing design, the method of introducing air for
combustion and the velocity of this air are of the greatest importance in securing good
combustion and in the effects on the character and shape of the flame. Such burners
Page 300
are located at the front of the furnace and various methods have been tried for
introducing the air for combustion. Where, in the spray burners, air is ordinarily
admitted through a checkerwork under the burner proper, with the mechanical burner,
it is almost universally admitted around the burner. Early experiments with these air
distributors were confined largely to single or duplicate cones used with the idea of
directing the air to the axis of the burner. A highly successful method of such air
introduction, developed by Messrs. Peabody and Irish of The Babcock & Wilcox Co.,
is by means of what they term an “impeller plate”. This consists of a circular metal
disk with an opening at the center for the oil burner and with radial metal strips from
the center to the periphery turned at an angle which in the later designs may be altered
to give the air supply demanded by the rate of combustion.
[Pg 220]
The air so admitted does not necessarily require a whirling motion, but experiments
show that where the air is brought into contact with the oil spray with the right
“twist”, better combustion is secured and lower air pressures and less refinement of
adjustment of individual burners are required.
Mechanical burners have a distinct advantage over those in which steam is used as the
atomizing agent in that they lend themselves more readily to adjustment under wider
variations of load. For a given horse power there will ordinarily be installed a much
greater number of mechanical than steam atomizing burners. This in itself is a means
to better regulation, for with the steam atomizing burner, if one of a number is shut
off, there is a marked decrease in efficiency. This is due to the fact that with the air
admitted under the burner, it is ordinarily passing through the checkerwork regardless
of whether it is being utilized for combustion or not. With a mechanical burner, on the
other hand, where individual burners are shut off, air that would be admitted for such
burner, were it in operation, may also be shut off and there will be no undue loss from
excess air.
Further adjustment to meet load conditions is possible by a change in the oil pressure
acting on all burners at once. A good burner will atomize moderately heavy oil with
an oil pressure as low as 30 pounds per square inch and from that point up to 200
pounds or above. The heating of the oil also has an effect on the capacity of
individual burners and in this way a third method of adjustment is given. Under
working conditions, the oil pressure remaining constant, the capacity of each burner
will decrease as the temperature of the oil is increased though at low temperatures the
reverse is the case. Some experiments with a Texas crude oil having a flash point of
210 degrees showed that the capacity of a mechanical atomizing burner of the
Peabody type increased from 80 degrees Fahrenheit to 110 degrees Fahrenheit, from
which point it fell off rapidly to 140 degrees and then more slowly to the flash point.
introducing the air for combustion. Where, in the spray burners, air is ordinarily
admitted through a checkerwork under the burner proper, with the mechanical burner,
it is almost universally admitted around the burner. Early experiments with these air
distributors were confined largely to single or duplicate cones used with the idea of
directing the air to the axis of the burner. A highly successful method of such air
introduction, developed by Messrs. Peabody and Irish of The Babcock & Wilcox Co.,
is by means of what they term an “impeller plate”. This consists of a circular metal
disk with an opening at the center for the oil burner and with radial metal strips from
the center to the periphery turned at an angle which in the later designs may be altered
to give the air supply demanded by the rate of combustion.
[Pg 220]
The air so admitted does not necessarily require a whirling motion, but experiments
show that where the air is brought into contact with the oil spray with the right
“twist”, better combustion is secured and lower air pressures and less refinement of
adjustment of individual burners are required.
Mechanical burners have a distinct advantage over those in which steam is used as the
atomizing agent in that they lend themselves more readily to adjustment under wider
variations of load. For a given horse power there will ordinarily be installed a much
greater number of mechanical than steam atomizing burners. This in itself is a means
to better regulation, for with the steam atomizing burner, if one of a number is shut
off, there is a marked decrease in efficiency. This is due to the fact that with the air
admitted under the burner, it is ordinarily passing through the checkerwork regardless
of whether it is being utilized for combustion or not. With a mechanical burner, on the
other hand, where individual burners are shut off, air that would be admitted for such
burner, were it in operation, may also be shut off and there will be no undue loss from
excess air.
Further adjustment to meet load conditions is possible by a change in the oil pressure
acting on all burners at once. A good burner will atomize moderately heavy oil with
an oil pressure as low as 30 pounds per square inch and from that point up to 200
pounds or above. The heating of the oil also has an effect on the capacity of
individual burners and in this way a third method of adjustment is given. Under
working conditions, the oil pressure remaining constant, the capacity of each burner
will decrease as the temperature of the oil is increased though at low temperatures the
reverse is the case. Some experiments with a Texas crude oil having a flash point of
210 degrees showed that the capacity of a mechanical atomizing burner of the
Peabody type increased from 80 degrees Fahrenheit to 110 degrees Fahrenheit, from
which point it fell off rapidly to 140 degrees and then more slowly to the flash point.
Page 301
The above methods, together with the regulation possible through manipulation of the
boiler dampers, indicate the wide range of load conditions that may be handled with
an installation of this class of burners.
As has already been stated, results with mechanical atomizing burners that may be
considered very successful have been limited almost entirely to cases where forced
blast of some description has been used, the high velocity of the air entering being of
material assistance in securing the proper mixture of air with the oil spray. Much has
been done and is being done in the way of experiment with this class of apparatus
toward developing a successful mechanical atomizing burner for use with natural
draft, and there appears to be no reason why such experiments should not eventually
produce satisfactory results.
Steam Consumption of Burners—The Bureau of Steam Engineering, U. S. Navy,
made in 1901 an exhaustive series of tests of various oil burners that may be
considered as representing, in so far as the performance of the burners themselves is
concerned, the practice of that time. These tests showed that a burner utilizing air as
an atomizing agent, required for compressing the air from 1.06 to 7.45 per cent of the
total steam generated, the average being 3.18 per cent. Four tests of steam atomizing
burners showed a consumption of 3.98 to 5.77 per cent of the total steam, the average
being 4.8 per cent.
Improvement in burner design has largely reduced the steam consumption, though to
a greater degree in steam than in air atomizing burners. Recent experiments [Pg 221]
show that a good steam atomizing burner will require approximately 2 per cent of the
total steam generated by the boiler operated at or about its rated capacity. This figure
will decrease as the capacity is increased and is so low as to be practically negligible,
except in cases where the question of loss of feed water is all important. There are no
figures available as to the actual steam consumption of mechanical atomizing burners
but apparently this is small if the requirement is understood to be entirely apart from
the steam consumption of the apparatus producing the forced blast.
Capacity of Burners—A good steam atomizing burner properly located in a well-
designed oil furnace has a capacity of somewhat over 400 horse power. This question
of capacity of individual burners is largely one of the proper relation between the
number of burners used and the furnace volume. In some recent tests with a Babcock
& Wilcox boiler of 640 rated horse power, equipped with three burners,
approximately 1350 horse power was developed with an available draft of .55 inch at
the damper or 450 horse power per burner. Four burners were also tried in the same
furnace but the total steam generated did not exceed 1350 horse power or in this
instance 338 horse power per burner.
boiler dampers, indicate the wide range of load conditions that may be handled with
an installation of this class of burners.
As has already been stated, results with mechanical atomizing burners that may be
considered very successful have been limited almost entirely to cases where forced
blast of some description has been used, the high velocity of the air entering being of
material assistance in securing the proper mixture of air with the oil spray. Much has
been done and is being done in the way of experiment with this class of apparatus
toward developing a successful mechanical atomizing burner for use with natural
draft, and there appears to be no reason why such experiments should not eventually
produce satisfactory results.
Steam Consumption of Burners—The Bureau of Steam Engineering, U. S. Navy,
made in 1901 an exhaustive series of tests of various oil burners that may be
considered as representing, in so far as the performance of the burners themselves is
concerned, the practice of that time. These tests showed that a burner utilizing air as
an atomizing agent, required for compressing the air from 1.06 to 7.45 per cent of the
total steam generated, the average being 3.18 per cent. Four tests of steam atomizing
burners showed a consumption of 3.98 to 5.77 per cent of the total steam, the average
being 4.8 per cent.
Improvement in burner design has largely reduced the steam consumption, though to
a greater degree in steam than in air atomizing burners. Recent experiments [Pg 221]
show that a good steam atomizing burner will require approximately 2 per cent of the
total steam generated by the boiler operated at or about its rated capacity. This figure
will decrease as the capacity is increased and is so low as to be practically negligible,
except in cases where the question of loss of feed water is all important. There are no
figures available as to the actual steam consumption of mechanical atomizing burners
but apparently this is small if the requirement is understood to be entirely apart from
the steam consumption of the apparatus producing the forced blast.
Capacity of Burners—A good steam atomizing burner properly located in a well-
designed oil furnace has a capacity of somewhat over 400 horse power. This question
of capacity of individual burners is largely one of the proper relation between the
number of burners used and the furnace volume. In some recent tests with a Babcock
& Wilcox boiler of 640 rated horse power, equipped with three burners,
approximately 1350 horse power was developed with an available draft of .55 inch at
the damper or 450 horse power per burner. Four burners were also tried in the same
furnace but the total steam generated did not exceed 1350 horse power or in this
instance 338 horse power per burner.
Page 302
From the nature of mechanical atomizing burners, individual burners have not as
large a capacity as the steam atomizing class. In some tests on a Babcock & Wilcox
marine boiler, equipped with mechanical atomizing burners, the maximum horse
power developed per burner was approximately 105. Here again the burner capacity is
largely one of proper relation between furnace volume and number of burners.
Furnace Design—Too much stress cannot be laid on the importance of furnace design
for the use of this class of fuel. Provided a good type of burner is adopted the furnace
arrangement and the method of introducing air for combustion into the furnace are the
all important factors. No matter what the type of burner, satisfactory results cannot be
secured in a furnace not suited to the fuel.
The Babcock & Wilcox Co. has had much experience with the burning of oil as fuel
and an extended series of experiments by Mr. E. H. Peabody led to the development
and adoption of the Peabody furnace as being most eminently suited for this class of
work. Fig. 29 shows such a furnace applied to a Babcock & Wilcox boiler, and with
slight modification it can be as readily applied to any boiler of The Babcock &
Wilcox Co. manufacture. In the description of this furnace, its points of advantage
cover the requirements of oil-burning furnaces in general.
The atomized oil is introduced into the furnace in the direction in which it increases in
height. This increase in furnace volume in the direction of the flame insures free
expansion and a thorough mixture of the oil with the air, and the consequent complete
combustion of the gases before they come into contact with the tube heating surfaces.
In such a furnace flat flame burners should be used, preferably of the Peabody type, in
which the flame spreads outward toward the sides in the form of a fan. There is no
tendency of the flames to impinge directly on the heating surfaces, and the furnace
can handle any quantity of flame without danger of tube difficulties. The burners
should be so located that the flames from individual burners do not interfere nor
impinge to any extent on the side walls of the furnace, an even distribution of heat
being secured in this manner. The burners are operated from the boiler front and
peepholes are supplied through which the operator may watch the flame while
regulating the burners. The burners can be removed, inspected, or cleaned and
replaced in a few minutes. Air is admitted through a checkerwork of fire brick
supported on the furnace floor, the openings in the checkerwork being so arranged as
to give the best economic results in combustion.
[Pg 222]
[Pg 223] With steam atomizing burners introduced through the front of the boiler in
stationary practice, it is usually in the direction in which the furnace decreases in
height and it is with such an arrangement that difficulties through the loss of tubes
may be expected. With such an arrangement, the flame may impinge directly upon the
large a capacity as the steam atomizing class. In some tests on a Babcock & Wilcox
marine boiler, equipped with mechanical atomizing burners, the maximum horse
power developed per burner was approximately 105. Here again the burner capacity is
largely one of proper relation between furnace volume and number of burners.
Furnace Design—Too much stress cannot be laid on the importance of furnace design
for the use of this class of fuel. Provided a good type of burner is adopted the furnace
arrangement and the method of introducing air for combustion into the furnace are the
all important factors. No matter what the type of burner, satisfactory results cannot be
secured in a furnace not suited to the fuel.
The Babcock & Wilcox Co. has had much experience with the burning of oil as fuel
and an extended series of experiments by Mr. E. H. Peabody led to the development
and adoption of the Peabody furnace as being most eminently suited for this class of
work. Fig. 29 shows such a furnace applied to a Babcock & Wilcox boiler, and with
slight modification it can be as readily applied to any boiler of The Babcock &
Wilcox Co. manufacture. In the description of this furnace, its points of advantage
cover the requirements of oil-burning furnaces in general.
The atomized oil is introduced into the furnace in the direction in which it increases in
height. This increase in furnace volume in the direction of the flame insures free
expansion and a thorough mixture of the oil with the air, and the consequent complete
combustion of the gases before they come into contact with the tube heating surfaces.
In such a furnace flat flame burners should be used, preferably of the Peabody type, in
which the flame spreads outward toward the sides in the form of a fan. There is no
tendency of the flames to impinge directly on the heating surfaces, and the furnace
can handle any quantity of flame without danger of tube difficulties. The burners
should be so located that the flames from individual burners do not interfere nor
impinge to any extent on the side walls of the furnace, an even distribution of heat
being secured in this manner. The burners are operated from the boiler front and
peepholes are supplied through which the operator may watch the flame while
regulating the burners. The burners can be removed, inspected, or cleaned and
replaced in a few minutes. Air is admitted through a checkerwork of fire brick
supported on the furnace floor, the openings in the checkerwork being so arranged as
to give the best economic results in combustion.
[Pg 222]
[Pg 223] With steam atomizing burners introduced through the front of the boiler in
stationary practice, it is usually in the direction in which the furnace decreases in
height and it is with such an arrangement that difficulties through the loss of tubes
may be expected. With such an arrangement, the flame may impinge directly upon the
Page 303
tube surfaces and tube troubles from this source may arise, particularly where the feed
water has a tendency toward rapid scale formation. Such difficulties may be the result
of a blowpipe action on the part of the burner, the over heating of the tube due to oil
or scale within, or the actual erosion of the metal by particles of oil improperly
atomized. Such action need not be anticipated, provided the oil is burned with a short
flame. The flames from mechanical atomizing burners have a less velocity of
projection than those from steam atomizing burners and if introduced into the higher
end of the furnace, should not lead to tube difficulties provided they are properly
located and operated. This class of burner also will give the most satisfactory results
if introduced so that the flames travel in the direction of increase in furnace volume.
This is perhaps best exemplified by the very good results secured with mechanical
atomizing burners and Babcock & Wilcox marine boilers in which, due to the fact that
the boilers are fired from the low end, the flames from burners introduced through the
front are in this direction.
Fig. 29. Babcock & Wilcox Boiler, Equipped with a Peabody Oil Furnace
water has a tendency toward rapid scale formation. Such difficulties may be the result
of a blowpipe action on the part of the burner, the over heating of the tube due to oil
or scale within, or the actual erosion of the metal by particles of oil improperly
atomized. Such action need not be anticipated, provided the oil is burned with a short
flame. The flames from mechanical atomizing burners have a less velocity of
projection than those from steam atomizing burners and if introduced into the higher
end of the furnace, should not lead to tube difficulties provided they are properly
located and operated. This class of burner also will give the most satisfactory results
if introduced so that the flames travel in the direction of increase in furnace volume.
This is perhaps best exemplified by the very good results secured with mechanical
atomizing burners and Babcock & Wilcox marine boilers in which, due to the fact that
the boilers are fired from the low end, the flames from burners introduced through the
front are in this direction.
Fig. 29. Babcock & Wilcox Boiler, Equipped with a Peabody Oil Furnace
Page 304
Operation of Burners—When burners are not in use, or when they are being started
up, care must be taken to prevent oil from flowing and collecting on the floor of the
furnace before it is ignited. In starting a burner, the atomized fuel may be ignited by a
burning wad of oil-soaked waste held before it on an iron rod. To insure quick
ignition, the steam supply should be cut down. But little practice is required to
become an adept at lighting an oil fire. When ignition has taken place and the furnace
brought to an even heat, the steam should be cut down to the minimum amount
required for atomization. This amount can be determined from the appearance of the
flame. If sufficient steam is not supplied, particles of burning oil will drop to the
furnace floor, giving a scintillating appearance to the flame. The steam valves should
be opened just sufficiently to overcome this scintillating action.
Air Supply—From the nature of the fuel and the method of burning, the quantity of
air for combustion may be minimized. As with other fuels, when the amount of air
admitted is the minimum which will completely consume the oil, the results are the
best. The excess or deficiency of air can be judged by the appearance of the stack or
by observing the gases passing through the boiler settings. A perfectly clear stack
indicates excess air, whereas smoke indicates a deficiency. With properly designed
furnaces the best results are secured by running near the smoking point with a slight
haze in the gases. A slight variation in the air supply will affect the furnace conditions
in an oil burning boiler more than the same variation where coal is used, and for this
reason it is of the utmost importance that flue gas analysis be made frequently on oil-
burning boilers. With the air for combustion properly regulated by adjustment of any
checkerwork or any other device which may be used, and the dampers carefully set,
the flue gas analysis should show, for good furnace conditions, a percentage of CO2
between 13 and 14 per cent, with either no CO or but a trace.
In boiler plant operation it is difficult to regulate the steam supply to the burners and
the damper position to meet sudden and repeated variations in the load. A device
[Pg 224] has been patented which automatically regulates by means of the boiler
pressure the pressure of the steam to the burners, the oil to the burners and the
position of the boiler damper. Such a device has been shown to give good results in
plant operation where hand regulation is difficult at best, and in many instances is
unfortunately not even attempted.
Efficiency with Oil—As pointed out in enumerating the advantages of oil fuel over
coal, higher efficiencies are obtainable with the former. With boilers of approximately
500 horse power equipped with properly designed furnaces and burners, an efficiency
of 83 per cent is possible or making an allowance of 2 per cent for steam used by
burners, a net efficiency of 81 per cent. The conditions under which such efficiencies
are to be secured are distinctly test conditions in which careful operation is a prime
requisite. With furnace conditions that are not conductive to the best combustion, this
up, care must be taken to prevent oil from flowing and collecting on the floor of the
furnace before it is ignited. In starting a burner, the atomized fuel may be ignited by a
burning wad of oil-soaked waste held before it on an iron rod. To insure quick
ignition, the steam supply should be cut down. But little practice is required to
become an adept at lighting an oil fire. When ignition has taken place and the furnace
brought to an even heat, the steam should be cut down to the minimum amount
required for atomization. This amount can be determined from the appearance of the
flame. If sufficient steam is not supplied, particles of burning oil will drop to the
furnace floor, giving a scintillating appearance to the flame. The steam valves should
be opened just sufficiently to overcome this scintillating action.
Air Supply—From the nature of the fuel and the method of burning, the quantity of
air for combustion may be minimized. As with other fuels, when the amount of air
admitted is the minimum which will completely consume the oil, the results are the
best. The excess or deficiency of air can be judged by the appearance of the stack or
by observing the gases passing through the boiler settings. A perfectly clear stack
indicates excess air, whereas smoke indicates a deficiency. With properly designed
furnaces the best results are secured by running near the smoking point with a slight
haze in the gases. A slight variation in the air supply will affect the furnace conditions
in an oil burning boiler more than the same variation where coal is used, and for this
reason it is of the utmost importance that flue gas analysis be made frequently on oil-
burning boilers. With the air for combustion properly regulated by adjustment of any
checkerwork or any other device which may be used, and the dampers carefully set,
the flue gas analysis should show, for good furnace conditions, a percentage of CO2
between 13 and 14 per cent, with either no CO or but a trace.
In boiler plant operation it is difficult to regulate the steam supply to the burners and
the damper position to meet sudden and repeated variations in the load. A device
[Pg 224] has been patented which automatically regulates by means of the boiler
pressure the pressure of the steam to the burners, the oil to the burners and the
position of the boiler damper. Such a device has been shown to give good results in
plant operation where hand regulation is difficult at best, and in many instances is
unfortunately not even attempted.
Efficiency with Oil—As pointed out in enumerating the advantages of oil fuel over
coal, higher efficiencies are obtainable with the former. With boilers of approximately
500 horse power equipped with properly designed furnaces and burners, an efficiency
of 83 per cent is possible or making an allowance of 2 per cent for steam used by
burners, a net efficiency of 81 per cent. The conditions under which such efficiencies
are to be secured are distinctly test conditions in which careful operation is a prime
requisite. With furnace conditions that are not conductive to the best combustion, this
Page 305
figure may be decreased by from 5 to 10 per cent. In large properly designed plants,
however, the first named efficiency may be approached for uniform running
conditions, the nearness to which it is reached depending on the intelligence of the
operating crew. It must be remembered that the use of oil fuel presents to the careless
operator possibilities for wastefulness much greater than in plants where coal is fired,
and it therefore pays to go carefully into this feature.
Table 48 gives some representative tests with oil fuel.
TABLE 48
TESTS OF BABCOCK AND WILCOX BOILERS WITH OIL FUEL
Miami
Pacific Light Pacific Light
Copper
and Power and Power
Company
Plant Company Company
Los Angeles, Redondo,
Miami,
Cal. Cal.
Arizona
Horse
Rated Capacity of Boiler 467 604 600
Power
Duration of Test Hours 10 10 7 7 10 4
Steam Pressure by Gauge Pounds 156.4 156.9 184.7 184.9 183.4 189.5
Degrees
Temperature of Feed Water 62.6 61.1 93.4 101.2 157.7 156.6
F.
Degrees
Degrees of Superheat 83.7 144.3 103.4 139.6
F.
Factor of Evaporation 1.2004 1.2020 1.22271.2475 1.1676 1.1886
Draft in Furnace Inches .02 .05 .014 .19 .12 .22
Draft at Damper Inches .08 .15 .046 .47 .19 .67
Degrees
Temperature of Exit Gases 438 525 406 537 430 612
F.
CO2 Per Cent 14.3 12.1
Flue Gas Analysis {O Per Cent
CO Per Cent
3.8
0.0
6.8
0.0
Oil Burned per Hour Pounds 1147 1837 1439 2869 1404 3214
Water Evaporated per Hour
Pounds 18310 27855 22639 40375 21720 42863
from from and at 212 Degrees
Evaporation from and at 212
Pounds 15.96 15.16 15.73 14.07 15.47 13.34
Degrees per Pound of Oil
however, the first named efficiency may be approached for uniform running
conditions, the nearness to which it is reached depending on the intelligence of the
operating crew. It must be remembered that the use of oil fuel presents to the careless
operator possibilities for wastefulness much greater than in plants where coal is fired,
and it therefore pays to go carefully into this feature.
Table 48 gives some representative tests with oil fuel.
TABLE 48
TESTS OF BABCOCK AND WILCOX BOILERS WITH OIL FUEL
Miami
Pacific Light Pacific Light
Copper
and Power and Power
Company
Plant Company Company
Los Angeles, Redondo,
Miami,
Cal. Cal.
Arizona
Horse
Rated Capacity of Boiler 467 604 600
Power
Duration of Test Hours 10 10 7 7 10 4
Steam Pressure by Gauge Pounds 156.4 156.9 184.7 184.9 183.4 189.5
Degrees
Temperature of Feed Water 62.6 61.1 93.4 101.2 157.7 156.6
F.
Degrees
Degrees of Superheat 83.7 144.3 103.4 139.6
F.
Factor of Evaporation 1.2004 1.2020 1.22271.2475 1.1676 1.1886
Draft in Furnace Inches .02 .05 .014 .19 .12 .22
Draft at Damper Inches .08 .15 .046 .47 .19 .67
Degrees
Temperature of Exit Gases 438 525 406 537 430 612
F.
CO2 Per Cent 14.3 12.1
Flue Gas Analysis {O Per Cent
CO Per Cent
3.8
0.0
6.8
0.0
Oil Burned per Hour Pounds 1147 1837 1439 2869 1404 3214
Water Evaporated per Hour
Pounds 18310 27855 22639 40375 21720 42863
from from and at 212 Degrees
Evaporation from and at 212
Pounds 15.96 15.16 15.73 14.07 15.47 13.34
Degrees per Pound of Oil
Page 306
Per Cent of Rated Capacity
Pounds 113.6 172.9 108.6 193.8 104.9 207.1
Developed
B. t. u. per Pound of Oil B. t. u. 18626 18518 18326 18096 18600 18600
Efficiency Per Cent 83.15 79.46 83.29 76.02 80.70 69.6
Burning Oil in Connection with Other Fuels—Considerable attention has been
recently given to the burning of oil in connection with other fuels, and a combination
of this sort may be advisable either with the view to increasing the boiler [Pg 225]
capacity to assist over peak loads, or to keep the boiler in operation where there is the
possibility of a temporary failure of the primary fuel. It would appear from
experiments that such a combination gives satisfactory results from the standpoint of
both capacity and efficiency, if the two fuels are burned in separate furnaces.
Satisfactory results cannot ordinarily be obtained when it is attempted to burn oil fuel
in the same furnace as the primary fuel, as it is practically impossible to admit the
proper amount of air for combustion for each of the two fuels simultaneously. The
Babcock & Wilcox boiler lends itself readily to a double furnace arrangement and
Fig. 30 shows an installation where oil fuel is burned as an auxiliary to wood.
Fig. 30. Babcock & Wilcox Boiler Set with Combination Oil and Wood-
burning Furnace
Pounds 113.6 172.9 108.6 193.8 104.9 207.1
Developed
B. t. u. per Pound of Oil B. t. u. 18626 18518 18326 18096 18600 18600
Efficiency Per Cent 83.15 79.46 83.29 76.02 80.70 69.6
Burning Oil in Connection with Other Fuels—Considerable attention has been
recently given to the burning of oil in connection with other fuels, and a combination
of this sort may be advisable either with the view to increasing the boiler [Pg 225]
capacity to assist over peak loads, or to keep the boiler in operation where there is the
possibility of a temporary failure of the primary fuel. It would appear from
experiments that such a combination gives satisfactory results from the standpoint of
both capacity and efficiency, if the two fuels are burned in separate furnaces.
Satisfactory results cannot ordinarily be obtained when it is attempted to burn oil fuel
in the same furnace as the primary fuel, as it is practically impossible to admit the
proper amount of air for combustion for each of the two fuels simultaneously. The
Babcock & Wilcox boiler lends itself readily to a double furnace arrangement and
Fig. 30 shows an installation where oil fuel is burned as an auxiliary to wood.
Fig. 30. Babcock & Wilcox Boiler Set with Combination Oil and Wood-
burning Furnace
Page 307
Water-gas Tar—Water-gas tar, or gas-house tar, is a by-product of the coal used in
the manufacture of water gas. It is slightly heavier than crude oil and has a
comparatively low flash point. In burning, it should be heated only to a temperature
which makes it sufficiently fluid, and any furnace suitable for crude oil is in general
suitable for water-gas tar. Care should be taken where this fuel is used to install a
suitable apparatus for straining it before it is fed to the burner.
[Pg 226]
Babcock & Wilcox Boilers Fired with Blast Furnace Gas at the Bethlehem Steel
Co., Bethlehem, Pa. This Company Operates 12,900 Horse Power of Babcock &
Wilcox Boilers
FOOTNOTES
[44] Includes N.
[45] Includes silt.
[46] Net efficiency = gross efficiency less 2 per cent for steam used in atomizing oil.
Heat value of oil = 18500 B. t. u.
One ton of coal weighs 2000 pounds. One barrel of oil weighs 336 pounds. One gallon of
oil weighs 8 pounds.
the manufacture of water gas. It is slightly heavier than crude oil and has a
comparatively low flash point. In burning, it should be heated only to a temperature
which makes it sufficiently fluid, and any furnace suitable for crude oil is in general
suitable for water-gas tar. Care should be taken where this fuel is used to install a
suitable apparatus for straining it before it is fed to the burner.
[Pg 226]
Babcock & Wilcox Boilers Fired with Blast Furnace Gas at the Bethlehem Steel
Co., Bethlehem, Pa. This Company Operates 12,900 Horse Power of Babcock &
Wilcox Boilers
FOOTNOTES
[44] Includes N.
[45] Includes silt.
[46] Net efficiency = gross efficiency less 2 per cent for steam used in atomizing oil.
Heat value of oil = 18500 B. t. u.
One ton of coal weighs 2000 pounds. One barrel of oil weighs 336 pounds. One gallon of
oil weighs 8 pounds.
Page 308
[Pg 227]
Page 309
GASEOUS FUELS AND THEIR COMBUSTION
Of the gaseous fuels available for steam generating purposes, the most
common are blast furnace gas, natural gas and by-product coke oven gas.
Blast furnace gas, as implied by its name, is a by-product from the blast
furnace of the iron industry. This gasification of the solid fuel in a blast
furnace results, 1st, through combustion by the oxygen of the blast; 2nd,
through contact with the incandescent ore (Fe2O3 + C = 2 FeO + CO and
FeO + C = Fe + CO); and 3rd, through the agency of CO2 either formed in
the process of reduction or driven from the carbonates charged either as ore
or flux.
Approximately 90 per cent of the fuel consumed in all of the blast furnaces
of the United States is coke. The consumption of coke per ton of iron made
varies from 1600 to 3600 pounds per ton of 2240 pounds of iron. This
consumption depends upon the quality of the coal, the nature of the ore, the
quality of the pig iron produced and the equipment and management of the
plant. The average consumption, and one which is approximately correct for
ordinary conditions, is 2000 pounds of coke per gross ton (2240 pounds) of
pig iron. The gas produced in a gas furnace per ton of pig iron is obtained
from the weight of fixed carbon gasified, the weight of the oxygen
combined with the material of charge reduced, the weight of the gaseous
constituents of the flux and the weight of air delivered by the blowing
engine and the weight of volatile combustible contained in the coke.
Ordinarily, this weight of gas will be found to be approximately five times
the weight of the coke burned, or 10,000 pounds per ton of pig iron
produced.
With the exception of the small amount of carbon in combination with
hydrogen as methane, and a very small percentage of free hydrogen,
ordinarily less than 0.1 per cent, the calorific value of blast furnace gas is
due to the CO content which when united with sufficient oxygen when
burned under a boiler, burns further to CO2. The heat value of such gas will
vary in most cases from 85 to 100 B. t. u. per cubic foot under standard
Of the gaseous fuels available for steam generating purposes, the most
common are blast furnace gas, natural gas and by-product coke oven gas.
Blast furnace gas, as implied by its name, is a by-product from the blast
furnace of the iron industry. This gasification of the solid fuel in a blast
furnace results, 1st, through combustion by the oxygen of the blast; 2nd,
through contact with the incandescent ore (Fe2O3 + C = 2 FeO + CO and
FeO + C = Fe + CO); and 3rd, through the agency of CO2 either formed in
the process of reduction or driven from the carbonates charged either as ore
or flux.
Approximately 90 per cent of the fuel consumed in all of the blast furnaces
of the United States is coke. The consumption of coke per ton of iron made
varies from 1600 to 3600 pounds per ton of 2240 pounds of iron. This
consumption depends upon the quality of the coal, the nature of the ore, the
quality of the pig iron produced and the equipment and management of the
plant. The average consumption, and one which is approximately correct for
ordinary conditions, is 2000 pounds of coke per gross ton (2240 pounds) of
pig iron. The gas produced in a gas furnace per ton of pig iron is obtained
from the weight of fixed carbon gasified, the weight of the oxygen
combined with the material of charge reduced, the weight of the gaseous
constituents of the flux and the weight of air delivered by the blowing
engine and the weight of volatile combustible contained in the coke.
Ordinarily, this weight of gas will be found to be approximately five times
the weight of the coke burned, or 10,000 pounds per ton of pig iron
produced.
With the exception of the small amount of carbon in combination with
hydrogen as methane, and a very small percentage of free hydrogen,
ordinarily less than 0.1 per cent, the calorific value of blast furnace gas is
due to the CO content which when united with sufficient oxygen when
burned under a boiler, burns further to CO2. The heat value of such gas will
vary in most cases from 85 to 100 B. t. u. per cubic foot under standard
Page 310
conditions. In modern practice, where the blast is heated by hot blast stoves,
approximately 15 per cent of the total amount of gas is used for this
purpose, leaving 85 per cent of the total for use under boilers or in gas
engines, that is, approximately 8500 pounds of gas per ton of pig iron
produced. In a modern blast furnace plant, the gas serves ordinarily as the
only fuel required. Table 49 gives the analyses of several samples of blast
furnace gas.
TABLE 49
TYPICAL ANALYSES OF BLAST FURNACE GAS
CO2 O CO H CH4 N
Bessemer Furnace 9.850.3632.733.14 … 53.92
Bessemer Furnace 11.4 … 27.7 1.9 0.3 58.7
Bessemer Furnace 10.0 … 26.2 3.1 0.2 60.5
Bessemer Furnace 9.1 … 28.7 2.7 0.2 59.3
Bessemer Furnace 13.5 … 25.2 1.43 … 59.87
Bessemer Furnace[47] 10.9 … 27.8 2.8 0.2 58.3
Ferro Manganese Furnace 7.1 … 30.1 … … 62.8[48]
Basic Ore Furnace 16.0 0.2 23.6 … … 60.2[48]
[Pg 228]
Until recently, the important consideration in the burning of blast furnace
gas has been the capacity that can be developed with practically no
attention given to the aspect of efficiency. This phase of the question is now
drawing attention and furnaces especially designed for good efficiency with
this class of fuel are demanded. The essential feature is ample combustion
space, in which the combustion of gases may be practically completed
before striking the heating surfaces. The gases have the power of burning
out completely after striking the heating surfaces, provided the initial
temperature is sufficiently high, but where the combustion is completed
before such time, the results secured are more satisfactory. A furnace
volume of approximately 1 to 1.5 cubic feet per rated boiler horse power
will give a combustion space that is ample.
approximately 15 per cent of the total amount of gas is used for this
purpose, leaving 85 per cent of the total for use under boilers or in gas
engines, that is, approximately 8500 pounds of gas per ton of pig iron
produced. In a modern blast furnace plant, the gas serves ordinarily as the
only fuel required. Table 49 gives the analyses of several samples of blast
furnace gas.
TABLE 49
TYPICAL ANALYSES OF BLAST FURNACE GAS
CO2 O CO H CH4 N
Bessemer Furnace 9.850.3632.733.14 … 53.92
Bessemer Furnace 11.4 … 27.7 1.9 0.3 58.7
Bessemer Furnace 10.0 … 26.2 3.1 0.2 60.5
Bessemer Furnace 9.1 … 28.7 2.7 0.2 59.3
Bessemer Furnace 13.5 … 25.2 1.43 … 59.87
Bessemer Furnace[47] 10.9 … 27.8 2.8 0.2 58.3
Ferro Manganese Furnace 7.1 … 30.1 … … 62.8[48]
Basic Ore Furnace 16.0 0.2 23.6 … … 60.2[48]
[Pg 228]
Until recently, the important consideration in the burning of blast furnace
gas has been the capacity that can be developed with practically no
attention given to the aspect of efficiency. This phase of the question is now
drawing attention and furnaces especially designed for good efficiency with
this class of fuel are demanded. The essential feature is ample combustion
space, in which the combustion of gases may be practically completed
before striking the heating surfaces. The gases have the power of burning
out completely after striking the heating surfaces, provided the initial
temperature is sufficiently high, but where the combustion is completed
before such time, the results secured are more satisfactory. A furnace
volume of approximately 1 to 1.5 cubic feet per rated boiler horse power
will give a combustion space that is ample.
Page 311
Where there is the possibility of a failure of the gas supply, or where steam
is required when the blast furnace is shut down, coal fired grates of
sufficient size to get the required capacity should be installed. Where grates
of full size are not required, ignition grates should be installed, which need
be only large enough to carry a fire for igniting the gas or for generating a
small quantity of steam when the blast furnace is shut down. The area of
such grates has no direct bearing on the size of the boiler. The grates may be
placed directly under the gas burners in a standard position or may be
placed between two bridge walls back of the gas furnace and fired from the
side of the boiler. An advantage is claimed for the standard grate position
that it minimizes the danger of explosion on the re-ignition of gas after a
temporary stoppage of the supply and also that a considerable amount of
dirt, of which there is a good deal with this class of fuel and which is
difficult to remove, deposits on the fire and is taken out when the fires are
cleaned. In any event, regardless of the location of the grates, ample
provision should be made for removing this dust, not only from the furnace
but from the setting as a whole.
Blast furnace gas burners are of two general types: Those in which the air
for combustion is admitted around the burner proper, and those in which
this air is admitted through the burner. Whatever the design of burner,
provision should be made for the regulation of both the air and the gas
supply independently. A gas opening of .8 square inch per rated horse
power will enable a boiler to develop its nominal rating with a gas pressure
in the main of about 2 inches. This pressure is ordinarily from 6 to 8 inches
and in this way openings of the above size will be good for ordinary
overloads. The air openings should be from .75 to .85 square inch per rated
horse power. Good results are secured by inclining the gas burners slightly
downward toward the rear of the furnace. Where the burners are introduced
over coal fired grates, they should be set high enough to give headroom for
hand firing.
Ordinarily, individual stacks of 130 feet high with diameters as given in
Kent’s table for corresponding horse power are large enough for this class
of work. Such a stack will give a draft sufficient to allow a boiler to be
operated at 175 per cent of its rated capacity, and beyond this point the
capacity will not increase proportionately with the draft. When more than
is required when the blast furnace is shut down, coal fired grates of
sufficient size to get the required capacity should be installed. Where grates
of full size are not required, ignition grates should be installed, which need
be only large enough to carry a fire for igniting the gas or for generating a
small quantity of steam when the blast furnace is shut down. The area of
such grates has no direct bearing on the size of the boiler. The grates may be
placed directly under the gas burners in a standard position or may be
placed between two bridge walls back of the gas furnace and fired from the
side of the boiler. An advantage is claimed for the standard grate position
that it minimizes the danger of explosion on the re-ignition of gas after a
temporary stoppage of the supply and also that a considerable amount of
dirt, of which there is a good deal with this class of fuel and which is
difficult to remove, deposits on the fire and is taken out when the fires are
cleaned. In any event, regardless of the location of the grates, ample
provision should be made for removing this dust, not only from the furnace
but from the setting as a whole.
Blast furnace gas burners are of two general types: Those in which the air
for combustion is admitted around the burner proper, and those in which
this air is admitted through the burner. Whatever the design of burner,
provision should be made for the regulation of both the air and the gas
supply independently. A gas opening of .8 square inch per rated horse
power will enable a boiler to develop its nominal rating with a gas pressure
in the main of about 2 inches. This pressure is ordinarily from 6 to 8 inches
and in this way openings of the above size will be good for ordinary
overloads. The air openings should be from .75 to .85 square inch per rated
horse power. Good results are secured by inclining the gas burners slightly
downward toward the rear of the furnace. Where the burners are introduced
over coal fired grates, they should be set high enough to give headroom for
hand firing.
Ordinarily, individual stacks of 130 feet high with diameters as given in
Kent’s table for corresponding horse power are large enough for this class
of work. Such a stack will give a draft sufficient to allow a boiler to be
operated at 175 per cent of its rated capacity, and beyond this point the
capacity will not increase proportionately with the draft. When more than
Page 312
one boiler is connected with a stack, the draft available at the damper
should be equivalent to that which an individual stack of 130 feet high
would give. The draft from such a stack is necessary to maintain a suction
under all conditions throughout all parts of the setting. If the draft is
increased above that which such a stack will give, difficulties arise from
excess air for combustion with consequent loss in efficiency.
[Pg 229]
A poor mixing or laneing action in the furnace may result in a pulsating
effect of the gases in the setting. This action may at times be remedied by
admitting more air to the furnace. On account of the possibility of a
pulsating action of the gases under certain conditions and the puffs or
explosions, settings for this class of work should be carefully constructed
and thoroughly buckstayed and tied.
Natural Gas—Natural gas from different localities varies considerably in
composition and heating value. In Table 50 there is given a number of
analyses and heat values for natural gas from various localities.
This fuel is used for steam generating purposes to a considerable extent in
some localities, though such use is apparently decreasing. It is best burned
by employing a large number of small burners, each being capable of
handling 30 nominal rated horse power. The use of a large number of
burners obviates the danger of any laneing or blowpipe action, which might
be present where large burners are used. Ordinarily, such a gas, as it enters
the burners, is under a pressure of about 8 ounces. For the purpose of
comparison, all observations should be based on gas reduced to the standard
conditions of temperature and pressure, namely 32 degrees Fahrenheit and
14.7 pounds per square inch. When the temperature and pressure
corresponding to meter readings are known, the volume of gas under
standard conditions may be obtained by multiplying the meter readings in
cubic feet by 33.54 P/T, in which P equals the absolute pressure in pounds
per square inch and T equals the absolute temperature of the gas at the
meter. In boiler testing work, the evaporation should always be reduced to
that per cubic foot of gas under standard conditions.
should be equivalent to that which an individual stack of 130 feet high
would give. The draft from such a stack is necessary to maintain a suction
under all conditions throughout all parts of the setting. If the draft is
increased above that which such a stack will give, difficulties arise from
excess air for combustion with consequent loss in efficiency.
[Pg 229]
A poor mixing or laneing action in the furnace may result in a pulsating
effect of the gases in the setting. This action may at times be remedied by
admitting more air to the furnace. On account of the possibility of a
pulsating action of the gases under certain conditions and the puffs or
explosions, settings for this class of work should be carefully constructed
and thoroughly buckstayed and tied.
Natural Gas—Natural gas from different localities varies considerably in
composition and heating value. In Table 50 there is given a number of
analyses and heat values for natural gas from various localities.
This fuel is used for steam generating purposes to a considerable extent in
some localities, though such use is apparently decreasing. It is best burned
by employing a large number of small burners, each being capable of
handling 30 nominal rated horse power. The use of a large number of
burners obviates the danger of any laneing or blowpipe action, which might
be present where large burners are used. Ordinarily, such a gas, as it enters
the burners, is under a pressure of about 8 ounces. For the purpose of
comparison, all observations should be based on gas reduced to the standard
conditions of temperature and pressure, namely 32 degrees Fahrenheit and
14.7 pounds per square inch. When the temperature and pressure
corresponding to meter readings are known, the volume of gas under
standard conditions may be obtained by multiplying the meter readings in
cubic feet by 33.54 P/T, in which P equals the absolute pressure in pounds
per square inch and T equals the absolute temperature of the gas at the
meter. In boiler testing work, the evaporation should always be reduced to
that per cubic foot of gas under standard conditions.
Page 313
TABLE 50
TYPICAL ANALYSES (BY VOLUME) AND CALORIFIC VALUES OF
NATURAL GAS FROM VARIOUS LOCALITIES
Heavy B. t. u. per
Locality of
H CH4 CO CO2 N O Hydro- H2S Cubic Foot
Well
carbons Calculated[49]
Anderson,
1.8693.07 0.73 0.26 3.020.42 0.47 0.15 1017
Ind.
Marion,
1.2093.16 0.60 0.30 3.430.55 0.15 0.20 1009
Ind.
Muncie,
2.3592.67 0.45 0.25 3.530.35 0.25 0.15 1004
Ind.
Olean, N. Y. … 96.50 0.50 … … 2.00 1.00 … 1018
Findlay, O. 1.6493.35 0.41 0.25 3.410.39 0.35 0.20 1011
St. Ive, Pa. 6.1075.54 Trace 0.34 … … 18.12 … 1117
Cherry
22.5060.27 … 2.28 7.320.83 6.80 … 842
Tree, Pa.
Grapeville,
24.5614.93 Trace Trace 18.691.22 40.60 … 925
Pa.
Harvey
Well, Butler 13.5080.00 Trace 0.66 … … 5.72 … 998
Co., Pa.
Pittsburgh,
9.6457.85 1.00 … 23.412.10 6.00 … 748
Pa.
Pittsburgh,
20.0272.18 1.00 0.80 … 1.10 4.30 … 917
Pa.
Pittsburgh,
26.1665.25 0.80 0.60 … 0.80 6.30 … 899
Pa.
When natural gas is the only fuel, the burners should be evenly distributed
over the lower portion of the boiler front. If the fuel is used as an auxiliary
to coal, the burners may be placed through the fire front. A large
combustion space is essential and a volume of .75 cubic feet per rated horse
power will be found to give good [Pg 230]
[Pg 231] results. The burners should be of a design which give the gas and air
TYPICAL ANALYSES (BY VOLUME) AND CALORIFIC VALUES OF
NATURAL GAS FROM VARIOUS LOCALITIES
Heavy B. t. u. per
Locality of
H CH4 CO CO2 N O Hydro- H2S Cubic Foot
Well
carbons Calculated[49]
Anderson,
1.8693.07 0.73 0.26 3.020.42 0.47 0.15 1017
Ind.
Marion,
1.2093.16 0.60 0.30 3.430.55 0.15 0.20 1009
Ind.
Muncie,
2.3592.67 0.45 0.25 3.530.35 0.25 0.15 1004
Ind.
Olean, N. Y. … 96.50 0.50 … … 2.00 1.00 … 1018
Findlay, O. 1.6493.35 0.41 0.25 3.410.39 0.35 0.20 1011
St. Ive, Pa. 6.1075.54 Trace 0.34 … … 18.12 … 1117
Cherry
22.5060.27 … 2.28 7.320.83 6.80 … 842
Tree, Pa.
Grapeville,
24.5614.93 Trace Trace 18.691.22 40.60 … 925
Pa.
Harvey
Well, Butler 13.5080.00 Trace 0.66 … … 5.72 … 998
Co., Pa.
Pittsburgh,
9.6457.85 1.00 … 23.412.10 6.00 … 748
Pa.
Pittsburgh,
20.0272.18 1.00 0.80 … 1.10 4.30 … 917
Pa.
Pittsburgh,
26.1665.25 0.80 0.60 … 0.80 6.30 … 899
Pa.
When natural gas is the only fuel, the burners should be evenly distributed
over the lower portion of the boiler front. If the fuel is used as an auxiliary
to coal, the burners may be placed through the fire front. A large
combustion space is essential and a volume of .75 cubic feet per rated horse
power will be found to give good [Pg 230]
[Pg 231] results. The burners should be of a design which give the gas and air
Page 314
a rotary motion to insure a proper mixture. A checkerwork wall is
sometimes placed in the furnace about 3 feet from the burners to break up
the flame, but with a good design of burner this is unnecessary. Where the
gas is burned alone and no grates are furnished, good results are secured by
inclining the burner downward to the rear at a slight angle.
1600 Horse-power Installation of Babcock & Wilcox Boilers and
Superheaters at the Carnegie Natural Gas Co., Underwood, W. Va.
Natural Gas is the Fuel Burned under these Boilers
sometimes placed in the furnace about 3 feet from the burners to break up
the flame, but with a good design of burner this is unnecessary. Where the
gas is burned alone and no grates are furnished, good results are secured by
inclining the burner downward to the rear at a slight angle.
1600 Horse-power Installation of Babcock & Wilcox Boilers and
Superheaters at the Carnegie Natural Gas Co., Underwood, W. Va.
Natural Gas is the Fuel Burned under these Boilers
Page 315
By-product Coke Oven Gas—By-product coke oven gas is a product of the
destructive distillation of coal in a distilling or by-product coke oven. In this
class of apparatus the gases, instead of being burned at the point of their
origin, as in a beehive or retort coke oven, are taken from the oven through
an uptake pipe, cooled and yield as by-products tar, ammonia, illuminating
and fuel gas. A certain portion of the gas product is burned in the ovens and
the remainder used or sold for illuminating or fuel purposes, the methods of
utilizing the gas varying with plant operation and locality.
Table 51 gives the analyses and heat value of certain samples of by-product
coke oven gas utilized for fuel purposes.
This gas is nearer to natural gas in its heat value than is blast furnace gas,
and in general the remarks as to the proper methods of burning natural gas
and the features to be followed in furnace design hold as well for by-
product coke oven gas.
TABLE 51 The essential difference in
burning the two fuels is the
TYPICAL ANALYSES OF BY- pressure under which it
PRODUCT COKE OVEN GAS reaches the gas burner.
B.t.u. per Where this is ordinarily from
CO2 O CO CH4 H N 4 to 8 ounces in the case of
Cubic Foot
0.75 Trace 6.0 28.15 53.0 12.1 505 natural gas, it is
2.00 Trace 3.2 18.80 57.2 18.0 399 approximately 4 inches of
water in the case of by-
3.20 0.4 6.3 29.60 41.6 16.1 551
product coke oven gas. This
0.80 1.6 4.9 28.40 54.2 10.1 460
necessitates the use of larger
gas openings in the burners
for the latter class of fuel than for the former.
By-product coke oven gas comes to the burners saturated with moisture and
provision should be made for the blowing out of water of condensation.
This gas too, carries a large proportion of tar and hydrocarbons which form
a deposit in the burners and provision should be made for cleaning this out.
This is best accomplished by an attachment which permits the blowing out
of the burners by steam.
destructive distillation of coal in a distilling or by-product coke oven. In this
class of apparatus the gases, instead of being burned at the point of their
origin, as in a beehive or retort coke oven, are taken from the oven through
an uptake pipe, cooled and yield as by-products tar, ammonia, illuminating
and fuel gas. A certain portion of the gas product is burned in the ovens and
the remainder used or sold for illuminating or fuel purposes, the methods of
utilizing the gas varying with plant operation and locality.
Table 51 gives the analyses and heat value of certain samples of by-product
coke oven gas utilized for fuel purposes.
This gas is nearer to natural gas in its heat value than is blast furnace gas,
and in general the remarks as to the proper methods of burning natural gas
and the features to be followed in furnace design hold as well for by-
product coke oven gas.
TABLE 51 The essential difference in
burning the two fuels is the
TYPICAL ANALYSES OF BY- pressure under which it
PRODUCT COKE OVEN GAS reaches the gas burner.
B.t.u. per Where this is ordinarily from
CO2 O CO CH4 H N 4 to 8 ounces in the case of
Cubic Foot
0.75 Trace 6.0 28.15 53.0 12.1 505 natural gas, it is
2.00 Trace 3.2 18.80 57.2 18.0 399 approximately 4 inches of
water in the case of by-
3.20 0.4 6.3 29.60 41.6 16.1 551
product coke oven gas. This
0.80 1.6 4.9 28.40 54.2 10.1 460
necessitates the use of larger
gas openings in the burners
for the latter class of fuel than for the former.
By-product coke oven gas comes to the burners saturated with moisture and
provision should be made for the blowing out of water of condensation.
This gas too, carries a large proportion of tar and hydrocarbons which form
a deposit in the burners and provision should be made for cleaning this out.
This is best accomplished by an attachment which permits the blowing out
of the burners by steam.
Page 316
FOOTNOTES
[47] Average of 20 samples.
[48] Includes H and CH4.
[49] B. t. u. approximate. For method of calculation, see page 175.
[47] Average of 20 samples.
[48] Includes H and CH4.
[49] B. t. u. approximate. For method of calculation, see page 175.
Page 317
[Pg 232]
Page 318
UTILIZATION OF WASTE HEAT
While it has been long recognized that the reclamation of heat from the
waste gases of various industrial processes would lead to a great saving in
fuel and labor, the problem has, until recently, never been given the attention
that its importance merits. It is true that installations have been made for the
utilization of such gases, but in general they have consisted simply in the
placing of a given amount of boiler heating surface in the path of the gases
and those making the installations have been satisfied with whatever power
has been generated, no attention being given to the proportioning of either
the heating surface or the gas passages to meet the peculiar characteristics of
the particular class of waste gas available. The Babcock & Wilcox Co. has
recently gone into the question of the utilization of what has been known as
waste heat with great thoroughness, and the results secured by their
installations with practically all operations yielding such gases are eminently
successful.
TABLE 52 The power that
can be obtained
TEMPERATURE OF WASTE GASES FROM from waste
VARIOUS INDUSTRIAL PROCESSES gases depends
Temperature[50] upon their
Waste Heat From temperature and
Degrees
Brick Kilns 2000-2300 weight, and
Zinc Furnaces 2000-2300 both of these
factors vary
Copper Matte Reverberatory Furnaces 2000-2200
widely in
Beehive Coke Ovens 1800-2000 different
Cement Kilns 1200-1600[51] commercial
Nickel Refining Furnaces 1500-1750 operations.
Open Hearth Steel Furnaces 1100-1400 Table 52 gives
a list of certain
processes yielding waste gases the heat of which is available for the
generation of steam and the approximate temperature of such gases. It
should be understood that the temperatures in the table are the average of the
While it has been long recognized that the reclamation of heat from the
waste gases of various industrial processes would lead to a great saving in
fuel and labor, the problem has, until recently, never been given the attention
that its importance merits. It is true that installations have been made for the
utilization of such gases, but in general they have consisted simply in the
placing of a given amount of boiler heating surface in the path of the gases
and those making the installations have been satisfied with whatever power
has been generated, no attention being given to the proportioning of either
the heating surface or the gas passages to meet the peculiar characteristics of
the particular class of waste gas available. The Babcock & Wilcox Co. has
recently gone into the question of the utilization of what has been known as
waste heat with great thoroughness, and the results secured by their
installations with practically all operations yielding such gases are eminently
successful.
TABLE 52 The power that
can be obtained
TEMPERATURE OF WASTE GASES FROM from waste
VARIOUS INDUSTRIAL PROCESSES gases depends
Temperature[50] upon their
Waste Heat From temperature and
Degrees
Brick Kilns 2000-2300 weight, and
Zinc Furnaces 2000-2300 both of these
factors vary
Copper Matte Reverberatory Furnaces 2000-2200
widely in
Beehive Coke Ovens 1800-2000 different
Cement Kilns 1200-1600[51] commercial
Nickel Refining Furnaces 1500-1750 operations.
Open Hearth Steel Furnaces 1100-1400 Table 52 gives
a list of certain
processes yielding waste gases the heat of which is available for the
generation of steam and the approximate temperature of such gases. It
should be understood that the temperatures in the table are the average of the
Page 319
range of a complete cycle of the operation and that the minimum and
maximum temperatures may vary largely from the figures given.
The maximum available horse power that may be secured from such gases is
represented by the formula:
W (T - t) s
H. P. = ––––––––––––––––– (23)
33,479
Where W = the weight of gases passing per hour,
T = temperature of gases entering heating surface,
t = temperature leaving heating surface,
s = specific heat of gases.
The initial temperature and the weight or volume of gas will depend, as
stated, upon the process involved. The exit temperature will depend, to a
certain extent, upon the temperature of the entering gases, but will be
governed mainly by the efficiency of the heating surfaces installed for the
absorption of the heat.
Where the temperature of the gas available is high, approaching that found
in direct fired boiler practice, the problem is simple and the question of
design of boiler [Pg 233] becomes one of adapting the proper amount of
heating surface to the volume of gas to be handled. With such temperatures,
and a volume of gas available approximately in accordance with that found
in direct fired boiler practice, a standard boiler or one but slightly modified
from the standard will serve the purpose satisfactorily. As the temperatures
become lower, however, the problem is more difficult and the departure from
standard practice more radical. With low temperature gases, to obtain a heat
transfer rate at all comparable with that found in ordinary boiler practice, the
lack of temperature must be offset by an added velocity of the gases in their
passage over the heating surfaces. In securing the velocity necessary to give
a heat transfer rate with low temperature gases sufficient to make the
installation of waste heat boilers show a reasonable return on the investment,
the frictional resistance to the gases through the boiler becomes greatly in
excess of what would be considered good practice in direct fired boilers.
Practically all operations yielding waste gases require that nothing be done
maximum temperatures may vary largely from the figures given.
The maximum available horse power that may be secured from such gases is
represented by the formula:
W (T - t) s
H. P. = ––––––––––––––––– (23)
33,479
Where W = the weight of gases passing per hour,
T = temperature of gases entering heating surface,
t = temperature leaving heating surface,
s = specific heat of gases.
The initial temperature and the weight or volume of gas will depend, as
stated, upon the process involved. The exit temperature will depend, to a
certain extent, upon the temperature of the entering gases, but will be
governed mainly by the efficiency of the heating surfaces installed for the
absorption of the heat.
Where the temperature of the gas available is high, approaching that found
in direct fired boiler practice, the problem is simple and the question of
design of boiler [Pg 233] becomes one of adapting the proper amount of
heating surface to the volume of gas to be handled. With such temperatures,
and a volume of gas available approximately in accordance with that found
in direct fired boiler practice, a standard boiler or one but slightly modified
from the standard will serve the purpose satisfactorily. As the temperatures
become lower, however, the problem is more difficult and the departure from
standard practice more radical. With low temperature gases, to obtain a heat
transfer rate at all comparable with that found in ordinary boiler practice, the
lack of temperature must be offset by an added velocity of the gases in their
passage over the heating surfaces. In securing the velocity necessary to give
a heat transfer rate with low temperature gases sufficient to make the
installation of waste heat boilers show a reasonable return on the investment,
the frictional resistance to the gases through the boiler becomes greatly in
excess of what would be considered good practice in direct fired boilers.
Practically all operations yielding waste gases require that nothing be done
Page 320
in the way of impairing the draft at the furnace outlet, as this might interfere
with the operation of the primary furnace. The installation of a waste heat
boiler, therefore, very frequently necessitates providing sufficient
mechanical draft to overcome the frictional resistance of the gases through
the heating surfaces and still leave ample draft available to meet the
maximum requirements of the primary furnace.
Where the temperature and volume of the gases are in line with what are
found in ordinary direct fired practice, the area of the gas passages may be
practically standard. With the volume of gas known, the draft loss through
the heating surfaces may be obtained from experimental data and this
additional draft requirement met by the installation of a stack sufficient to
take care of this draft loss and still leave draft enough for operating the
furnace at its maximum capacity.
Where the temperatures are low, the added frictional resistance will
ordinarily be too great to allow the draft required to be secured by additional
stack height and the installation of a fan is necessary. Such a fan should be
capable of handling the maximum volume of gas that the furnace may
produce, and of maintaining a suction equivalent to the maximum frictional
resistance of such volume through the boiler plus the maximum draft
requirement at the furnace outlet. Stacks and fans for this class of work
should be figured on the safe side. Where a fan installation is necessary, the
loss of draft in the fan connections should be considered, and in figuring
conservatively it should be remembered that a fan of ample size may be run
as economically as a smaller fan, whereas the smaller fan, if overloaded, is
operated with a large loss in efficiency. In practically any installation where
low temperature gas requires a fan to give the proper heat transfer from the
gases, the cost of the fan and of the energy to drive it will be more than
offset by the added power from the boiler secured by its use. Furthermore,
the installation of such a fan will frequently increase the capacity of the
industrial furnace, in connection with which the waste heat boilers are
installed.
In proportioning heating surfaces and gas passages for waste heat work there
are so many factors bearing directly on what constitutes the proper
installation that it is impossible to set any fixed rules. Each individual
installation must be considered by itself as well as the particular
with the operation of the primary furnace. The installation of a waste heat
boiler, therefore, very frequently necessitates providing sufficient
mechanical draft to overcome the frictional resistance of the gases through
the heating surfaces and still leave ample draft available to meet the
maximum requirements of the primary furnace.
Where the temperature and volume of the gases are in line with what are
found in ordinary direct fired practice, the area of the gas passages may be
practically standard. With the volume of gas known, the draft loss through
the heating surfaces may be obtained from experimental data and this
additional draft requirement met by the installation of a stack sufficient to
take care of this draft loss and still leave draft enough for operating the
furnace at its maximum capacity.
Where the temperatures are low, the added frictional resistance will
ordinarily be too great to allow the draft required to be secured by additional
stack height and the installation of a fan is necessary. Such a fan should be
capable of handling the maximum volume of gas that the furnace may
produce, and of maintaining a suction equivalent to the maximum frictional
resistance of such volume through the boiler plus the maximum draft
requirement at the furnace outlet. Stacks and fans for this class of work
should be figured on the safe side. Where a fan installation is necessary, the
loss of draft in the fan connections should be considered, and in figuring
conservatively it should be remembered that a fan of ample size may be run
as economically as a smaller fan, whereas the smaller fan, if overloaded, is
operated with a large loss in efficiency. In practically any installation where
low temperature gas requires a fan to give the proper heat transfer from the
gases, the cost of the fan and of the energy to drive it will be more than
offset by the added power from the boiler secured by its use. Furthermore,
the installation of such a fan will frequently increase the capacity of the
industrial furnace, in connection with which the waste heat boilers are
installed.
In proportioning heating surfaces and gas passages for waste heat work there
are so many factors bearing directly on what constitutes the proper
installation that it is impossible to set any fixed rules. Each individual
installation must be considered by itself as well as the particular
Page 321
characteristics of the gases available, such as their temperature and volume,
and the presence of dust or tar-like substances, and all must be given the
proper weight in the determination of the design of the heating surfaces and
gas passages for the specific set of conditions.
[Pg 234]
Fig. 31. Curve Showing Relation Between Gas Temperature, Heating
Surface passed over,
and Amount of Steam Generated.
Ten Square Feet of Heating Surface are Assumed as Equivalent to
One Boiler Horse Power
[Pg 235]
Fig. 31 shows the relation of gas temperatures, heating surface passed over
and work done by such surface for use in cases where the temperatures
approach those found in direct fired practice and where the volume of gas
available is approximately that with which one horse power may be
developed on 10 square feet of heating surface. The curve assumes what
and the presence of dust or tar-like substances, and all must be given the
proper weight in the determination of the design of the heating surfaces and
gas passages for the specific set of conditions.
[Pg 234]
Fig. 31. Curve Showing Relation Between Gas Temperature, Heating
Surface passed over,
and Amount of Steam Generated.
Ten Square Feet of Heating Surface are Assumed as Equivalent to
One Boiler Horse Power
[Pg 235]
Fig. 31 shows the relation of gas temperatures, heating surface passed over
and work done by such surface for use in cases where the temperatures
approach those found in direct fired practice and where the volume of gas
available is approximately that with which one horse power may be
developed on 10 square feet of heating surface. The curve assumes what
Page 322
may be considered standard gas passage areas, and further, that there is no
heat absorbed by direct radiation from the fire.
Experiments have shown that this curve is very nearly correct for the
conditions assumed. Such being the case, its application in waste heat work
is clear. Decreasing or increasing the velocity of the gases over the heating
surfaces from what might be considered normal direct fired practice, that is,
decreasing or increasing the frictional loss through the boiler will increase or
decrease the amount of heating surface necessary to develop one boiler horse
power. The application of Fig. 31 to such use may best be seen by an
example:
Assume the entering gas temperatures to be 1470 degrees and that the gases
are cooled to 570 degrees. From the curve, under what are assumed to be
standard conditions, the gases have passed over 19 per cent of the heating
surface by the time they have been cooled 1470 degrees. When cooled to
570 degrees, 78 per cent of the heating surface has been passed over. The
work done in relation to the standard of the curve is represented by (1470 -
570) ÷ (2500 - 500) = 45 per cent. (These figures may also be read from the
curve in terms of the per cent of the work done by different parts of the
heating surfaces.) That is, 78 per cent - 19 per cent = 59 per cent of the
standard heating surface has done 45 per cent of the standard amount of
work. 59 ÷ 45 = 1.31, which is the ratio of surface of the assumed case to the
standard case of the curve. Expressed differently, there will be required 13.1
square feet of heating surface in the assumed case to develop a horse power
as against 10 square feet in the standard case.
The gases available for this class of work are almost invariably very dirty. It
is essential for the successful operation of waste-heat boilers that ample
provision be made for cleaning by the installation of access doors through
which all parts of the setting may be reached. In many instances, such as
waste-heat boilers set in connection with cement kilns, settling chambers are
provided for the dust before the gases reach the boiler.
By-passes for the gases should in all cases be provided to enable the boiler to
be shut down for cleaning and repairs without interfering with the operation
of the primary furnace. All connections from furnace to boilers should be
heat absorbed by direct radiation from the fire.
Experiments have shown that this curve is very nearly correct for the
conditions assumed. Such being the case, its application in waste heat work
is clear. Decreasing or increasing the velocity of the gases over the heating
surfaces from what might be considered normal direct fired practice, that is,
decreasing or increasing the frictional loss through the boiler will increase or
decrease the amount of heating surface necessary to develop one boiler horse
power. The application of Fig. 31 to such use may best be seen by an
example:
Assume the entering gas temperatures to be 1470 degrees and that the gases
are cooled to 570 degrees. From the curve, under what are assumed to be
standard conditions, the gases have passed over 19 per cent of the heating
surface by the time they have been cooled 1470 degrees. When cooled to
570 degrees, 78 per cent of the heating surface has been passed over. The
work done in relation to the standard of the curve is represented by (1470 -
570) ÷ (2500 - 500) = 45 per cent. (These figures may also be read from the
curve in terms of the per cent of the work done by different parts of the
heating surfaces.) That is, 78 per cent - 19 per cent = 59 per cent of the
standard heating surface has done 45 per cent of the standard amount of
work. 59 ÷ 45 = 1.31, which is the ratio of surface of the assumed case to the
standard case of the curve. Expressed differently, there will be required 13.1
square feet of heating surface in the assumed case to develop a horse power
as against 10 square feet in the standard case.
The gases available for this class of work are almost invariably very dirty. It
is essential for the successful operation of waste-heat boilers that ample
provision be made for cleaning by the installation of access doors through
which all parts of the setting may be reached. In many instances, such as
waste-heat boilers set in connection with cement kilns, settling chambers are
provided for the dust before the gases reach the boiler.
By-passes for the gases should in all cases be provided to enable the boiler to
be shut down for cleaning and repairs without interfering with the operation
of the primary furnace. All connections from furnace to boilers should be
Page 323
kept tight to prevent the infiltration of air, with the consequent lowering of
gas temperatures.
Auxiliary gas or coal fired grates must be installed to insure continuity in the
operation of the boiler where the operation of the furnace is intermittent or
where it may be desired to run the boiler with the primary furnace not in
operation. Such grates are sometimes used continuously where the gases
available are not sufficient to develop the required horse power from a given
amount of heating surface.
Fear has at times been expressed that certain waste gases, such as those
containing sulphur fumes, will have a deleterious action on the heating
surface of the boiler. This feature has been carefully watched, however, and
from plants in operation it would appear that in the absence of water or
steam leaks within the setting, there is no such harmful action.
[Pg 236]
gas temperatures.
Auxiliary gas or coal fired grates must be installed to insure continuity in the
operation of the boiler where the operation of the furnace is intermittent or
where it may be desired to run the boiler with the primary furnace not in
operation. Such grates are sometimes used continuously where the gases
available are not sufficient to develop the required horse power from a given
amount of heating surface.
Fear has at times been expressed that certain waste gases, such as those
containing sulphur fumes, will have a deleterious action on the heating
surface of the boiler. This feature has been carefully watched, however, and
from plants in operation it would appear that in the absence of water or
steam leaks within the setting, there is no such harmful action.
[Pg 236]
Page 324
Fig. 32. Babcock & Wilcox Boiler Arranged for Utilizing Waste Heat
from Open Hearth Furnace.
This Setting may be Modified to Take Care of Practically any Kind of
Waste Gas
FOOTNOTES
[50] Temperatures are average over one cycle of operation and may vary widely
as to maximum and minimum.
[51] Dependant upon length of kiln.
from Open Hearth Furnace.
This Setting may be Modified to Take Care of Practically any Kind of
Waste Gas
FOOTNOTES
[50] Temperatures are average over one cycle of operation and may vary widely
as to maximum and minimum.
[51] Dependant upon length of kiln.
Page 325
[Pg 237]
Page 326
CHIMNEYS AND DRAFT
The height and diameter of a properly designed chimney depend upon the amount
of fuel to be burned, its nature, the design of the flue, with its arrangement relative
to the boiler or boilers, and the altitude of the plant above sea level. There are so
many factors involved that as yet there has been produced no formula which is
satisfactory in taking them all into consideration, and the methods used for
determining stack sizes are largely empirical. In this chapter a method sufficiently
comprehensive and accurate to cover all practical cases will be developed and
illustrated.
Draft is the difference in pressure available for producing a flow of the gases. If
the gases within a stack be heated, each cubic foot will expand, and the weight of
the expanded gas per cubic foot will be less than that of a cubic foot of the cold air
outside the chimney. Therefore, the unit pressure at the stack base due to the weight
of the column of heated gas will be less than that due to a column of cold air. This
difference in pressure, like the difference in head of water, will cause a flow of the
gases into the base of the stack. In its passage to the stack the cold air must pass
through the furnace or furnaces of the boilers connected to it, and it in turn becomes
heated. This newly heated gas will also rise in the stack and the action will be
continuous.
The intensity of the draft, or difference in pressure, is usually measured in inches of
water. Assuming an atmospheric temperature of 62 degrees Fahrenheit and the
temperature of the gases in the chimney as 500 degrees Fahrenheit, and, neglecting
for the moment the difference in density between the chimney gases and the air, the
difference between the weights of the external air and the internal flue gases per
cubic foot is .0347 pound, obtained as follows:
Weight of a cubic foot of air at 62 degrees Fahrenheit = .0761 pound
Weight of a cubic foot of air at 500 degrees Fahrenheit = .0414 pound
–––––––––
Difference = .0347 pound
Therefore, a chimney 100 feet high, assumed for the purpose of illustration to be
suspended in the air, would have a pressure exerted on each square foot of its cross
sectional area at its base of .0347 × 100 = 3.47 pounds. As a cubic foot of water at
62 degrees Fahrenheit weighs 62.32 pounds, an inch of water would exert a
The height and diameter of a properly designed chimney depend upon the amount
of fuel to be burned, its nature, the design of the flue, with its arrangement relative
to the boiler or boilers, and the altitude of the plant above sea level. There are so
many factors involved that as yet there has been produced no formula which is
satisfactory in taking them all into consideration, and the methods used for
determining stack sizes are largely empirical. In this chapter a method sufficiently
comprehensive and accurate to cover all practical cases will be developed and
illustrated.
Draft is the difference in pressure available for producing a flow of the gases. If
the gases within a stack be heated, each cubic foot will expand, and the weight of
the expanded gas per cubic foot will be less than that of a cubic foot of the cold air
outside the chimney. Therefore, the unit pressure at the stack base due to the weight
of the column of heated gas will be less than that due to a column of cold air. This
difference in pressure, like the difference in head of water, will cause a flow of the
gases into the base of the stack. In its passage to the stack the cold air must pass
through the furnace or furnaces of the boilers connected to it, and it in turn becomes
heated. This newly heated gas will also rise in the stack and the action will be
continuous.
The intensity of the draft, or difference in pressure, is usually measured in inches of
water. Assuming an atmospheric temperature of 62 degrees Fahrenheit and the
temperature of the gases in the chimney as 500 degrees Fahrenheit, and, neglecting
for the moment the difference in density between the chimney gases and the air, the
difference between the weights of the external air and the internal flue gases per
cubic foot is .0347 pound, obtained as follows:
Weight of a cubic foot of air at 62 degrees Fahrenheit = .0761 pound
Weight of a cubic foot of air at 500 degrees Fahrenheit = .0414 pound
–––––––––
Difference = .0347 pound
Therefore, a chimney 100 feet high, assumed for the purpose of illustration to be
suspended in the air, would have a pressure exerted on each square foot of its cross
sectional area at its base of .0347 × 100 = 3.47 pounds. As a cubic foot of water at
62 degrees Fahrenheit weighs 62.32 pounds, an inch of water would exert a
Page 327
pressure of 62.32 ÷ 12 = 5.193 pounds per square foot. The 100-foot stack would,
therefore, under the above temperature conditions, show a draft of 3.47 ÷ 5.193 or
approximately 0.67 inches of water.
The method best suited for determining the proper proportion of stacks and flues is
dependent upon the principle that if the cross sectional area of the stack is
sufficiently large for the volume of gases to be handled, the intensity of the draft
will depend directly upon the height; therefore, the method of procedure is as
follows:
1st. Select a stack of such height as will produce the draft required by the particular
character of the fuel and the amount to be burned per square foot of grate surface.
2nd. Determine the cross sectional area necessary to handle the gases without undue
frictional losses.
[Pg 238]
The application of these rules follows:
Draft Formula—The force or intensity of the draft, not allowing for the difference
in the density of the air and of the flue gases, is given by the formula:
1 1
D = 0.52 H × P (T - T )
––– ––––
1
(24)
in which
D = draft produced, measured in inches of water,
H = height of top of stack above grate bars in feet,
P = atmospheric pressure in pounds per square inch,
T = absolute atmospheric temperature,
T1 = absolute temperature of stack gases.
In this formula no account is taken of the density of the flue gases, it being assumed
that it is the same as that of air. Any error arising from this assumption is negligible
in practice as a factor of correction is applied in using the formula to cover the
difference between the theoretical figures and those corresponding to actual
operating conditions.
therefore, under the above temperature conditions, show a draft of 3.47 ÷ 5.193 or
approximately 0.67 inches of water.
The method best suited for determining the proper proportion of stacks and flues is
dependent upon the principle that if the cross sectional area of the stack is
sufficiently large for the volume of gases to be handled, the intensity of the draft
will depend directly upon the height; therefore, the method of procedure is as
follows:
1st. Select a stack of such height as will produce the draft required by the particular
character of the fuel and the amount to be burned per square foot of grate surface.
2nd. Determine the cross sectional area necessary to handle the gases without undue
frictional losses.
[Pg 238]
The application of these rules follows:
Draft Formula—The force or intensity of the draft, not allowing for the difference
in the density of the air and of the flue gases, is given by the formula:
1 1
D = 0.52 H × P (T - T )
––– ––––
1
(24)
in which
D = draft produced, measured in inches of water,
H = height of top of stack above grate bars in feet,
P = atmospheric pressure in pounds per square inch,
T = absolute atmospheric temperature,
T1 = absolute temperature of stack gases.
In this formula no account is taken of the density of the flue gases, it being assumed
that it is the same as that of air. Any error arising from this assumption is negligible
in practice as a factor of correction is applied in using the formula to cover the
difference between the theoretical figures and those corresponding to actual
operating conditions.
Page 328
The force of draft at sea level (which corresponds to an atmospheric pressure of
14.7 pounds per square inch) produced by a chimney 100 feet high with the
temperature of the air at 60 degrees Fahrenheit and that of the flue gases at 500
degrees Fahrenheit is,
1 1
D = 0.52 × 100 × 14.7 ( 521 - 961 ) = 0.67
–––––– ––––––
Under the same temperature conditions this chimney at an atmospheric pressure of
10 pounds per square inch (which corresponds to an altitude of about 10,000 feet
above sea level) would produce a draft of,
1 1
D = 0.52 × 100 × 10 ( 521 - 961 ) = 0.45
–––––– ––––––
For use in applying this formula it is convenient to tabulate values of the product
1 1
0.52 × 14.7 (T - T )
––– ––––
1
which we will call K, for various values of T1. With these values calculated for
assumed atmospheric temperature and pressure (24) becomes
D = KH (25)
For average conditions the atmospheric pressure may be considered 14.7 pounds
per square inch, and the temperature 60 degrees Fahrenheit. For these values and
various stack temperatures K becomes:
Temperature Stack Gases Constant K
750 .0084
700 .0081
650 .0078
600 .0075
550 .0071
500 .0067
14.7 pounds per square inch) produced by a chimney 100 feet high with the
temperature of the air at 60 degrees Fahrenheit and that of the flue gases at 500
degrees Fahrenheit is,
1 1
D = 0.52 × 100 × 14.7 ( 521 - 961 ) = 0.67
–––––– ––––––
Under the same temperature conditions this chimney at an atmospheric pressure of
10 pounds per square inch (which corresponds to an altitude of about 10,000 feet
above sea level) would produce a draft of,
1 1
D = 0.52 × 100 × 10 ( 521 - 961 ) = 0.45
–––––– ––––––
For use in applying this formula it is convenient to tabulate values of the product
1 1
0.52 × 14.7 (T - T )
––– ––––
1
which we will call K, for various values of T1. With these values calculated for
assumed atmospheric temperature and pressure (24) becomes
D = KH (25)
For average conditions the atmospheric pressure may be considered 14.7 pounds
per square inch, and the temperature 60 degrees Fahrenheit. For these values and
various stack temperatures K becomes:
Temperature Stack Gases Constant K
750 .0084
700 .0081
650 .0078
600 .0075
550 .0071
500 .0067
Page 329
450 .0063
400 .0058
350 .0053
[Pg 239]
Draft Losses—The intensity of the draft as determined by the above formula is
theoretical and can never be observed with a draft gauge or any recording device.
However, if the ashpit doors of the boiler are closed and there is no perceptible
leakage of air through the boiler setting or flue, the draft measured at the stack base
will be approximately the same as the theoretical draft. The difference existing at
other times represents the pressure necessary to force the gases through the stack
against their own inertia and the friction against the sides. This difference will
increase with the velocity of the gases. With the ashpit doors closed the volume of
gases passing to the stack are a minimum and the maximum force of draft will be
shown by a gauge.
As draft measurements are taken along the path of the gases, the readings grow less
as the points at which they are taken are farther from the stack, until in the boiler
ashpit, with the ashpit doors open for freely admitting the air, there is little or no
perceptible rise in the water of the gauge. The breeching, the boiler damper, the
baffles and the tubes, and the coal on the grates all retard the passage of the gases,
and the draft from the chimney is required to overcome the resistance offered by the
various factors. The draft at the rear of the boiler setting where connection is made
to the stack or flue may be 0.5 inch, while in the furnace directly over the fire it
may not be over, say, 0.15 inch, the difference being the draft required to overcome
the resistance offered in forcing the gases through the tubes and around the baffling.
One of the most important factors to be considered in designing a stack is the
pressure required to force the air for combustion through the bed of fuel on the
grates. This pressure will vary with the nature of the fuel used, and in many
instances will be a large percentage of the total draft. In the case of natural draft, its
measure is found directly by noting the draft in the furnace, for with properly
designed ashpit doors it is evident that the pressure under the grates will not differ
sensibly from atmospheric pressure.
Loss in Stack—The difference between the theoretical draft as determined by
formula (24) and the amount lost by friction in the stack proper is the available
draft, or that which the draft gauge indicates when connected to the base of the
stack. The sum of the losses of draft in the flue, boiler and furnace must be
equivalent to the available draft, and as these quantities can be determined from
400 .0058
350 .0053
[Pg 239]
Draft Losses—The intensity of the draft as determined by the above formula is
theoretical and can never be observed with a draft gauge or any recording device.
However, if the ashpit doors of the boiler are closed and there is no perceptible
leakage of air through the boiler setting or flue, the draft measured at the stack base
will be approximately the same as the theoretical draft. The difference existing at
other times represents the pressure necessary to force the gases through the stack
against their own inertia and the friction against the sides. This difference will
increase with the velocity of the gases. With the ashpit doors closed the volume of
gases passing to the stack are a minimum and the maximum force of draft will be
shown by a gauge.
As draft measurements are taken along the path of the gases, the readings grow less
as the points at which they are taken are farther from the stack, until in the boiler
ashpit, with the ashpit doors open for freely admitting the air, there is little or no
perceptible rise in the water of the gauge. The breeching, the boiler damper, the
baffles and the tubes, and the coal on the grates all retard the passage of the gases,
and the draft from the chimney is required to overcome the resistance offered by the
various factors. The draft at the rear of the boiler setting where connection is made
to the stack or flue may be 0.5 inch, while in the furnace directly over the fire it
may not be over, say, 0.15 inch, the difference being the draft required to overcome
the resistance offered in forcing the gases through the tubes and around the baffling.
One of the most important factors to be considered in designing a stack is the
pressure required to force the air for combustion through the bed of fuel on the
grates. This pressure will vary with the nature of the fuel used, and in many
instances will be a large percentage of the total draft. In the case of natural draft, its
measure is found directly by noting the draft in the furnace, for with properly
designed ashpit doors it is evident that the pressure under the grates will not differ
sensibly from atmospheric pressure.
Loss in Stack—The difference between the theoretical draft as determined by
formula (24) and the amount lost by friction in the stack proper is the available
draft, or that which the draft gauge indicates when connected to the base of the
stack. The sum of the losses of draft in the flue, boiler and furnace must be
equivalent to the available draft, and as these quantities can be determined from
Page 330
record of experiments, the problem of designing a stack becomes one of
proportioning it to produce a certain available draft.
The loss in the stack due to friction of the gases can be calculated from the
following formula:
f W² C H
ΔD = –––––––––––––––– (26)
A³
in which
ΔD = draft loss in inches of water,
W = weight of gas in pounds passing per second,
C = perimeter of stack in feet,
H = height of stack in feet,
f = a constant with the following values at sea level:
.0015 for steel stacks, temperature of gases 600 degrees Fahrenheit.
.0011 for steel stacks, temperature of gases 350 degrees Fahrenheit.
.0020 for brick or brick-lined stacks, temperature of gases 600 degrees
Fahrenheit.
.0015 for brick or brick-lined stacks, temperature of gases 350 degrees
Fahrenheit.
Area of stack in square feet.
A =
[Pg 240]
proportioning it to produce a certain available draft.
The loss in the stack due to friction of the gases can be calculated from the
following formula:
f W² C H
ΔD = –––––––––––––––– (26)
A³
in which
ΔD = draft loss in inches of water,
W = weight of gas in pounds passing per second,
C = perimeter of stack in feet,
H = height of stack in feet,
f = a constant with the following values at sea level:
.0015 for steel stacks, temperature of gases 600 degrees Fahrenheit.
.0011 for steel stacks, temperature of gases 350 degrees Fahrenheit.
.0020 for brick or brick-lined stacks, temperature of gases 600 degrees
Fahrenheit.
.0015 for brick or brick-lined stacks, temperature of gases 350 degrees
Fahrenheit.
Area of stack in square feet.
A =
[Pg 240]
Page 331
24,420 Horse-power Installation of Babcock & Wilcox Boilers and
Superheaters, Equipped with Babcock & Wilcox Chain Grate Stokers in the
Quarry Street Station of the Commonwealth Edison Co., Chicago, Ill.
[Pg 241]
This formula can also be used for calculating the frictional losses for flues, in which
case, C = the perimeter of the flue in feet, H = the length of the flue in feet, the
other values being the same as for stacks.
The available draft is equal to the difference between the theoretical draft from
formula (25) and the loss from formula (26), hence:
f W² C H
d1 = available draft = KH - –––––––––––––––– (27)
A³
Table 53 gives the available draft in inches that a stack 100 feet high will produce
when serving different horse powers of boilers with the methods of calculation for
other heights.
Superheaters, Equipped with Babcock & Wilcox Chain Grate Stokers in the
Quarry Street Station of the Commonwealth Edison Co., Chicago, Ill.
[Pg 241]
This formula can also be used for calculating the frictional losses for flues, in which
case, C = the perimeter of the flue in feet, H = the length of the flue in feet, the
other values being the same as for stacks.
The available draft is equal to the difference between the theoretical draft from
formula (25) and the loss from formula (26), hence:
f W² C H
d1 = available draft = KH - –––––––––––––––– (27)
A³
Table 53 gives the available draft in inches that a stack 100 feet high will produce
when serving different horse powers of boilers with the methods of calculation for
other heights.
Page 332
TABLE 53
AVAILABLE DRAFT
CALCULATED FOR 100-FOOT STACK OF DIFFERENT DIAMETERS
ASSUMING STACK TEMPERATURE OF 500 DEGREES
FAHRENHEIT
AND 100 POUNDS OF GAS PER HORSE POWER
FOR OTHER HEIGHTS OF STACK MULTIPLY DRAFT BY HEIGHT ÷
100
Horse Diameter of Stack in Inches
Power 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120132144
100 .64
200 .55 .62
300 .41 .55 .61
400 .21 .46 .56 .61
500 .34 .50 .57 .61
600 .19 .42 .53 .59
700 .34 .48 .56 .60 .63
800 .23 .43 .52 .58 .61 .63
900 .36 .49 .56 .60 .62 .64
1000 .29 .45 .53 .58 .61 .63 .64
1100 .40 .50 .56 .60 .62 .63 .64
1200 .35 .47 .54 .58 .61 .63 .64 .65
1300 .29 .44 .52 .57 .60 .62 .63 .64 .65
1400 .40 .49 .55 .59 .61 .63 .64 .65 .65
1500 .36 .47 .53 .58 .60 .62 .63 .64 .65 .65
1600 .31 .43 .52 .56 .59 .62 .63 .64 .65 .65
1700 .41 .50 .55 .58 .61 .62 .64 .64 .65
1800 .37 .47 .54 .57 .60 .62 .63 .64 .65
1900 .34 .45 .52 .56 .59 .61 .63 .64 .64
2000 .43 .50 .55 .59 .61 .62 .63 .64
2100 .40 .49 .54 .58 .60 .62 .63 .64
2200 .38 .47 .53 .57 .59 .61 .62 .64
2300 .35 .45 .52 .56 .59 .61 .62 .63
2400 .32 .43 .50 .55 .58 .60 .62 .63
2500 .41 .49 .54 .57 .60 .61 .63
AVAILABLE DRAFT
CALCULATED FOR 100-FOOT STACK OF DIFFERENT DIAMETERS
ASSUMING STACK TEMPERATURE OF 500 DEGREES
FAHRENHEIT
AND 100 POUNDS OF GAS PER HORSE POWER
FOR OTHER HEIGHTS OF STACK MULTIPLY DRAFT BY HEIGHT ÷
100
Horse Diameter of Stack in Inches
Power 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120132144
100 .64
200 .55 .62
300 .41 .55 .61
400 .21 .46 .56 .61
500 .34 .50 .57 .61
600 .19 .42 .53 .59
700 .34 .48 .56 .60 .63
800 .23 .43 .52 .58 .61 .63
900 .36 .49 .56 .60 .62 .64
1000 .29 .45 .53 .58 .61 .63 .64
1100 .40 .50 .56 .60 .62 .63 .64
1200 .35 .47 .54 .58 .61 .63 .64 .65
1300 .29 .44 .52 .57 .60 .62 .63 .64 .65
1400 .40 .49 .55 .59 .61 .63 .64 .65 .65
1500 .36 .47 .53 .58 .60 .62 .63 .64 .65 .65
1600 .31 .43 .52 .56 .59 .62 .63 .64 .65 .65
1700 .41 .50 .55 .58 .61 .62 .64 .64 .65
1800 .37 .47 .54 .57 .60 .62 .63 .64 .65
1900 .34 .45 .52 .56 .59 .61 .63 .64 .64
2000 .43 .50 .55 .59 .61 .62 .63 .64
2100 .40 .49 .54 .58 .60 .62 .63 .64
2200 .38 .47 .53 .57 .59 .61 .62 .64
2300 .35 .45 .52 .56 .59 .61 .62 .63
2400 .32 .43 .50 .55 .58 .60 .62 .63
2500 .41 .49 .54 .57 .60 .61 .63
Page 333
Horse Diameter of Stack in Inches
Power 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120132144
2600 .47 .53 .56 .59 .61 .62 .64 .65
2700 .45 .52 .55 .58 .60 .62 .64 .65
2800 .44 .59 .55 .58 .60 .61 .64 .65
2900 .42 .49 .54 .57 .59 .61 .63 .65
3000 .40 .48 .53 .56 .59 .61 .63 .64
3100 .38 .47 .52 .56 .58 .60 .63 .64
3200 .45 .51 .55 .58 .60 .63 .64
3300 .44 .50 .54 .57 .59 .62 .64
3400 .42 .49 .53 .56 .59 .62 .64
3500 .40 .48 .52 .56 .58 .62 .64
3600 .47 .52 .55 .58 .61 .63
3700 .45 .51 .55 .57 .61 .63
3800 .44 .50 .54 .57 .61 .63
3900 .43 .49 .53 .56 .60 .63
4000 .42 .48 .52 .56 .60 .62
4100 .40 .47 .52 .55 .60 .62
4200 .39 .46 .51 .55 .59 .62
4300 .45 .50 .54 .59 .62
4400 .44 .49 .53 .59 .62
4500 .43 .49 .53 .58 .61
4600 .42 .48 .52 .58 .61
4700 .41 .47 .51 .57 .61
4800 .40 .46 .51 .57 .60
4900 .45 .50 .57 .60
5000 .44 .49 .56 .60
FOR OTHER STACK TEMPERATURES ADD OR DEDUCT
BEFORE MULTIPLYING BY HEIGHT ÷ 100 AS FOLLOWS[52]
For 750 Degrees F. For 650 Degrees F. For 550 Degrees F. For 400 Degrees F.
Add .17 inch. Add .11 inch. Add .04 inch. Deduct .09 inch.
For 700 Degrees F. For 600 Degrees F. For 450 Degrees F. For 350 Degrees F.
Add .14 inch. Add .08 inch. Deduct .04 inch. Deduct .14 inch.
[Pg 242]
Power 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120132144
2600 .47 .53 .56 .59 .61 .62 .64 .65
2700 .45 .52 .55 .58 .60 .62 .64 .65
2800 .44 .59 .55 .58 .60 .61 .64 .65
2900 .42 .49 .54 .57 .59 .61 .63 .65
3000 .40 .48 .53 .56 .59 .61 .63 .64
3100 .38 .47 .52 .56 .58 .60 .63 .64
3200 .45 .51 .55 .58 .60 .63 .64
3300 .44 .50 .54 .57 .59 .62 .64
3400 .42 .49 .53 .56 .59 .62 .64
3500 .40 .48 .52 .56 .58 .62 .64
3600 .47 .52 .55 .58 .61 .63
3700 .45 .51 .55 .57 .61 .63
3800 .44 .50 .54 .57 .61 .63
3900 .43 .49 .53 .56 .60 .63
4000 .42 .48 .52 .56 .60 .62
4100 .40 .47 .52 .55 .60 .62
4200 .39 .46 .51 .55 .59 .62
4300 .45 .50 .54 .59 .62
4400 .44 .49 .53 .59 .62
4500 .43 .49 .53 .58 .61
4600 .42 .48 .52 .58 .61
4700 .41 .47 .51 .57 .61
4800 .40 .46 .51 .57 .60
4900 .45 .50 .57 .60
5000 .44 .49 .56 .60
FOR OTHER STACK TEMPERATURES ADD OR DEDUCT
BEFORE MULTIPLYING BY HEIGHT ÷ 100 AS FOLLOWS[52]
For 750 Degrees F. For 650 Degrees F. For 550 Degrees F. For 400 Degrees F.
Add .17 inch. Add .11 inch. Add .04 inch. Deduct .09 inch.
For 700 Degrees F. For 600 Degrees F. For 450 Degrees F. For 350 Degrees F.
Add .14 inch. Add .08 inch. Deduct .04 inch. Deduct .14 inch.
[Pg 242]
Page 334
Fig. 33. Diameter of Stacks and Horse Power they will Serve
Computed from Formula (28). For brick or brick-lined stacks, increase the diameter 6 per cent
[Pg 243]
Height and Diameter of Stacks—From this formula (27) it becomes evident that a
stack of certain diameter, if it be increased in height, will produce the same
available draft as one of larger diameter, the additional height being required to
overcome the added frictional loss. It follows that among the various stacks that
would meet the requirements of a particular case there must be one which can be
constructed more cheaply than the others. It has been determined from the relation
Computed from Formula (28). For brick or brick-lined stacks, increase the diameter 6 per cent
[Pg 243]
Height and Diameter of Stacks—From this formula (27) it becomes evident that a
stack of certain diameter, if it be increased in height, will produce the same
available draft as one of larger diameter, the additional height being required to
overcome the added frictional loss. It follows that among the various stacks that
would meet the requirements of a particular case there must be one which can be
constructed more cheaply than the others. It has been determined from the relation
Page 335
of the cost of stacks to their diameters and heights, in connection with the formula
for available draft, that the minimum cost stack has a diameter dependent solely
upon the horse power of the boilers it serves, and a height proportional to the
available draft required.
Assuming 120 pounds of flue gas per hour for each boiler horse power, which
provides for ordinary overloads and the use of poor coal, the method above stated
gives:
For an unlined steel stack—diameter in inches = 4.68 (H. P.)2⁄5 (28)
For a stack lined with masonry—diameter in inches = 4.92 (H. P.)2⁄5 (29)
In both of these formulae H. P. = the rated horse power of the boiler.
From this formula the curve, Fig. 33, has been calculated and from it the stack
diameter for any boiler horse power can be selected.
For stoker practice where a large stack serves a number of boilers, the area is
usually made about one-third more than the above rules call for, which allows for
leakage of air through the setting of any idle boilers, irregularities in operating
conditions, etc.
Stacks with diameters determined as above will give an available draft which bears
a constant ratio of the theoretical draft, and allowing for the cooling of the gases in
their passage upward through the stack, this ratio is 8. Using this factor in formula
(25), and transposing, the height of the chimney becomes,
d1
H = ––––––– (30)
.8 K
Where H = height of stack in feet above the level of the grates,
d1 = available draft required,
K = constant as in formula.
Losses in Flues—The loss of draft in straight flues due to friction and inertia can be
calculated approximately from formula (26), which was given for loss in stacks. It
is to be borne in mind that C in this formula is the actual perimeter of the flue and is
least, relative to the cross sectional area, when the section is a circle, is greater for a
square section, and greatest for a rectangular section. The retarding effect of a
square flue is 12 per cent greater than that of a circular flue of the same area and
for available draft, that the minimum cost stack has a diameter dependent solely
upon the horse power of the boilers it serves, and a height proportional to the
available draft required.
Assuming 120 pounds of flue gas per hour for each boiler horse power, which
provides for ordinary overloads and the use of poor coal, the method above stated
gives:
For an unlined steel stack—diameter in inches = 4.68 (H. P.)2⁄5 (28)
For a stack lined with masonry—diameter in inches = 4.92 (H. P.)2⁄5 (29)
In both of these formulae H. P. = the rated horse power of the boiler.
From this formula the curve, Fig. 33, has been calculated and from it the stack
diameter for any boiler horse power can be selected.
For stoker practice where a large stack serves a number of boilers, the area is
usually made about one-third more than the above rules call for, which allows for
leakage of air through the setting of any idle boilers, irregularities in operating
conditions, etc.
Stacks with diameters determined as above will give an available draft which bears
a constant ratio of the theoretical draft, and allowing for the cooling of the gases in
their passage upward through the stack, this ratio is 8. Using this factor in formula
(25), and transposing, the height of the chimney becomes,
d1
H = ––––––– (30)
.8 K
Where H = height of stack in feet above the level of the grates,
d1 = available draft required,
K = constant as in formula.
Losses in Flues—The loss of draft in straight flues due to friction and inertia can be
calculated approximately from formula (26), which was given for loss in stacks. It
is to be borne in mind that C in this formula is the actual perimeter of the flue and is
least, relative to the cross sectional area, when the section is a circle, is greater for a
square section, and greatest for a rectangular section. The retarding effect of a
square flue is 12 per cent greater than that of a circular flue of the same area and
Page 336
that of a rectangular with sides as 1 and 1½, 15 per cent greater. The greater
resistance of the more or less uneven brick or concrete flue is provided for in the
value of the constants given for formula (26). Both steel and brick flues should be
short and should have as near a circular or square cross section as possible. Abrupt
turns are to be avoided, but as long easy sweeps require valuable space, it is often
desirable to increase the height of the stack rather than to take up added space in the
boiler room. Short right-angle turns reduce the draft by an amount which can be
roughly approximated as equal to 0.05 inch for each turn. The turns which the gases
make in leaving the damper box of a boiler, in entering a horizontal flue and in
turning up into a stack should always be considered. The cross sectional areas of the
passages leading from the boilers to the stack should be of ample size to provide
against undue frictional loss. It is poor economy to restrict the size of the flue and
thus make additional stack height [Pg 244
[Pg 245] necessary to overcome the added friction. The general practice is to make
flue areas the same or slightly larger than that of the stack; these should be,
preferably, at least 20 per cent greater, and a safe rule to follow in figuring flue
areas is to allow 35 square feet per 1000 horse power. It is unnecessary to maintain
the same size of flue the entire distance behind a row of boilers, and the areas at any
point may be made proportional to the volume of gases that will pass that point.
That is, the areas may be reduced as connections to various boilers are passed.
resistance of the more or less uneven brick or concrete flue is provided for in the
value of the constants given for formula (26). Both steel and brick flues should be
short and should have as near a circular or square cross section as possible. Abrupt
turns are to be avoided, but as long easy sweeps require valuable space, it is often
desirable to increase the height of the stack rather than to take up added space in the
boiler room. Short right-angle turns reduce the draft by an amount which can be
roughly approximated as equal to 0.05 inch for each turn. The turns which the gases
make in leaving the damper box of a boiler, in entering a horizontal flue and in
turning up into a stack should always be considered. The cross sectional areas of the
passages leading from the boilers to the stack should be of ample size to provide
against undue frictional loss. It is poor economy to restrict the size of the flue and
thus make additional stack height [Pg 244
[Pg 245] necessary to overcome the added friction. The general practice is to make
flue areas the same or slightly larger than that of the stack; these should be,
preferably, at least 20 per cent greater, and a safe rule to follow in figuring flue
areas is to allow 35 square feet per 1000 horse power. It is unnecessary to maintain
the same size of flue the entire distance behind a row of boilers, and the areas at any
point may be made proportional to the volume of gases that will pass that point.
That is, the areas may be reduced as connections to various boilers are passed.
Page 337
6000 Horse-power Installation of Babcock & Wilcox Boilers at the United
States Navy Yard, Washington, D. C.
With circular steel flues of approximately the same size as the stacks, or reduced
proportionally to the volume of gases they will handle, a convenient rule is to allow
0.1 inch draft loss per 100 feet of flue length and 0.05 inch for each right-angle
turn. These figures are also good for square or rectangular steel flues with areas
sufficiently large to provide against excessive frictional loss. For losses in brick or
concrete flues, these figures should be doubled.
Underground flues are less desirable than overhead or rear flues for the reason that
in most instances the gases will have to make more turns where underground flues
are used and because the cross sectional area of such flues will oftentimes be
decreased on account of an accumulation of dirt or water which it may be
impossible to remove.
In tall buildings, such as office buildings, it is frequently necessary in order to carry
spent gases above the roofs, to install a stack the height of which is out of all
proportion to the requirements of the boilers. In such cases it is permissible to
decrease the diameter of a stack, but care must be taken that this decrease is not
sufficient to cause a frictional loss in the stack as great as the added draft intensity
due to the increase in height, which local conditions make necessary.
In such cases also the fact that the stack diameter is permissibly decreased is no
reason why flue sizes connecting to the stack should be decreased. These should
still be figured in proportion to the area of the stack that would be furnished under
ordinary conditions or with an allowance of 35 square feet per 1000 horse power,
even though the cross sectional area appears out of proportion to the stack area.
Loss in Boiler—In calculating the available draft of a chimney 120 pounds per
hour has been used as the weight of the gases per boiler horse power. This covers an
overload of the boiler to an extent of 50 per cent and provides for the use of poor
coal. The loss in draft through a boiler proper will depend upon its type and baffling
and will increase with the per cent of rating at which it is run. No figures can be
given which will cover all conditions, but for approximate use in figuring the
available draft necessary it may be assumed that the loss through a boiler will be
0.25 inch where the boiler is run at rating, 0.40 inch where it is run at 150 per cent
of its rated capacity, and 0.70 inch where it is run at 200 per cent of its rated
capacity.
Loss in Furnace—The draft loss in the furnace or through the fuel bed varies
between wide limits. The air necessary for combustion must pass through the
States Navy Yard, Washington, D. C.
With circular steel flues of approximately the same size as the stacks, or reduced
proportionally to the volume of gases they will handle, a convenient rule is to allow
0.1 inch draft loss per 100 feet of flue length and 0.05 inch for each right-angle
turn. These figures are also good for square or rectangular steel flues with areas
sufficiently large to provide against excessive frictional loss. For losses in brick or
concrete flues, these figures should be doubled.
Underground flues are less desirable than overhead or rear flues for the reason that
in most instances the gases will have to make more turns where underground flues
are used and because the cross sectional area of such flues will oftentimes be
decreased on account of an accumulation of dirt or water which it may be
impossible to remove.
In tall buildings, such as office buildings, it is frequently necessary in order to carry
spent gases above the roofs, to install a stack the height of which is out of all
proportion to the requirements of the boilers. In such cases it is permissible to
decrease the diameter of a stack, but care must be taken that this decrease is not
sufficient to cause a frictional loss in the stack as great as the added draft intensity
due to the increase in height, which local conditions make necessary.
In such cases also the fact that the stack diameter is permissibly decreased is no
reason why flue sizes connecting to the stack should be decreased. These should
still be figured in proportion to the area of the stack that would be furnished under
ordinary conditions or with an allowance of 35 square feet per 1000 horse power,
even though the cross sectional area appears out of proportion to the stack area.
Loss in Boiler—In calculating the available draft of a chimney 120 pounds per
hour has been used as the weight of the gases per boiler horse power. This covers an
overload of the boiler to an extent of 50 per cent and provides for the use of poor
coal. The loss in draft through a boiler proper will depend upon its type and baffling
and will increase with the per cent of rating at which it is run. No figures can be
given which will cover all conditions, but for approximate use in figuring the
available draft necessary it may be assumed that the loss through a boiler will be
0.25 inch where the boiler is run at rating, 0.40 inch where it is run at 150 per cent
of its rated capacity, and 0.70 inch where it is run at 200 per cent of its rated
capacity.
Loss in Furnace—The draft loss in the furnace or through the fuel bed varies
between wide limits. The air necessary for combustion must pass through the
Page 338
interstices of the coal on the grate. Where these are large, as is the case with broken
coal, but little pressure is required to force the air through the bed; but if they are
small, as with bituminous slack or small sizes of anthracite, a much greater pressure
is needed. If the draft is insufficient the coal will accumulate on the grates and a
dead smoky fire will result with the accompanying poor combustion; if the draft is
too great, the coal may be rapidly consumed on certain portions of the grate,
leaving the fire thin in spots and a portion of the grates uncovered with the resulting
losses due to an excessive amount of air.
[Pg 246]
Fig. 34. Draft Required at Different Combustion Rates for Various Kinds of
Coal
Pg 247]
Draft Required for Different Fuels—For every kind of fuel and rate of
combustion there is a certain draft with which the best general results are obtained.
coal, but little pressure is required to force the air through the bed; but if they are
small, as with bituminous slack or small sizes of anthracite, a much greater pressure
is needed. If the draft is insufficient the coal will accumulate on the grates and a
dead smoky fire will result with the accompanying poor combustion; if the draft is
too great, the coal may be rapidly consumed on certain portions of the grate,
leaving the fire thin in spots and a portion of the grates uncovered with the resulting
losses due to an excessive amount of air.
[Pg 246]
Fig. 34. Draft Required at Different Combustion Rates for Various Kinds of
Coal
Pg 247]
Draft Required for Different Fuels—For every kind of fuel and rate of
combustion there is a certain draft with which the best general results are obtained.
Page 339
A comparatively light draft is best with the free burning bituminous coals and the
amount to use increases as the percentage of volatile matter diminishes and the
fixed carbon increases, being highest for the small sizes of anthracites. Numerous
other factors such as the thickness of fires, the percentage of ash and the air spaces
in the grates bear directly on this question of the draft best suited to a given
combustion rate. The effect of these factors can only be found by experiment. It is
almost impossible to show by one set of curves the furnace draft required at various
rates of combustion for all of the different conditions of fuel, etc., that may be met.
The curves in Fig. 34, however, give the furnace draft necessary to burn various
kinds of coal at the combustion rates indicated by the abscissae, for a general set of
conditions. These curves have been plotted from the records of numerous tests and
allow a safe margin for economically burning coals of the kinds noted.
Rate of Combustion—The amount of coal which can be burned per hour per square
foot of grate surface is governed by the character of the coal and the draft available.
When the boiler and grate are properly proportioned, the efficiency will be
practically the same, within reasonable limits, for different rates of combustion. The
area of the grate, and the ratio of this area to the boiler heating surface will depend
upon the nature of the fuel to be burned, and the stack should be so designed as to
give a draft sufficient to burn the maximum amount of fuel per square foot of grate
surface corresponding to the maximum evaporative requirements of the boiler.
Solution of a Problem—The stack diameter can be determined from the curve,
Fig. 33. The height can be determined by adding the draft losses in the furnace,
through the boiler and flues, and computing from formula (30) the height necessary
to give this draft.
Example: Proportion a stack for boilers rated at 2000 horse power, equipped with
stokers, and burning bituminous coal that will evaporate 8 pounds of water from
and at 212 degrees Fahrenheit per pound of fuel; the ratio of boiler heating surface
to grate surface being 50:1; the flues being 100 feet long and containing two right-
angle turns; the stack to be able to handle overloads of 50 per cent; and the rated
horse power of the boilers based on 10 square feet of heating surface per horse
power.
The atmospheric temperature may be assumed as 60 degrees Fahrenheit and the
flue temperatures at the maximum overload as 550 degrees Fahrenheit. The grate
surface equals 400 square feet. The total coal burned at rating = 2000 × 34½⁄8 = 8624
pounds. The coal per square foot of grate surface per hour at rating = 8624⁄400 = 22
pounds.
amount to use increases as the percentage of volatile matter diminishes and the
fixed carbon increases, being highest for the small sizes of anthracites. Numerous
other factors such as the thickness of fires, the percentage of ash and the air spaces
in the grates bear directly on this question of the draft best suited to a given
combustion rate. The effect of these factors can only be found by experiment. It is
almost impossible to show by one set of curves the furnace draft required at various
rates of combustion for all of the different conditions of fuel, etc., that may be met.
The curves in Fig. 34, however, give the furnace draft necessary to burn various
kinds of coal at the combustion rates indicated by the abscissae, for a general set of
conditions. These curves have been plotted from the records of numerous tests and
allow a safe margin for economically burning coals of the kinds noted.
Rate of Combustion—The amount of coal which can be burned per hour per square
foot of grate surface is governed by the character of the coal and the draft available.
When the boiler and grate are properly proportioned, the efficiency will be
practically the same, within reasonable limits, for different rates of combustion. The
area of the grate, and the ratio of this area to the boiler heating surface will depend
upon the nature of the fuel to be burned, and the stack should be so designed as to
give a draft sufficient to burn the maximum amount of fuel per square foot of grate
surface corresponding to the maximum evaporative requirements of the boiler.
Solution of a Problem—The stack diameter can be determined from the curve,
Fig. 33. The height can be determined by adding the draft losses in the furnace,
through the boiler and flues, and computing from formula (30) the height necessary
to give this draft.
Example: Proportion a stack for boilers rated at 2000 horse power, equipped with
stokers, and burning bituminous coal that will evaporate 8 pounds of water from
and at 212 degrees Fahrenheit per pound of fuel; the ratio of boiler heating surface
to grate surface being 50:1; the flues being 100 feet long and containing two right-
angle turns; the stack to be able to handle overloads of 50 per cent; and the rated
horse power of the boilers based on 10 square feet of heating surface per horse
power.
The atmospheric temperature may be assumed as 60 degrees Fahrenheit and the
flue temperatures at the maximum overload as 550 degrees Fahrenheit. The grate
surface equals 400 square feet. The total coal burned at rating = 2000 × 34½⁄8 = 8624
pounds. The coal per square foot of grate surface per hour at rating = 8624⁄400 = 22
pounds.
Page 340
The atmospheric temperature may be assumed as 60 degrees Fahrenheit and the
flue temperatures at the maximum overload as 550 degrees Fahrenheit. The grate
surface equals 400 square feet.
For 50 per cent overload the combustion rate will be approximately 60 per cent
greater than this or 1.60 × 22 = 35 pounds per square foot of grate surface per hour.
The furnace draft required for the combustion rate, from the curve, Fig. 34, is 0.6
inch. The loss in the boiler will be 0.4 inch, in the flue 0.1 inch, and in the turns 2 ×
0.05 = 0.1 inch. The available draft required at the base of the stack is, therefore,
Inches
Boiler 0.4
Furnace 0.6
Flues 0.1
Turns 0.1
–––––
Total 1.2
[Pg 248]
Since the available draft is 80 per cent of the theoretical draft, this draft due to the
height required is 1.2 ÷ .8 = 1.5 inch.
The chimney constant for temperatures of 60 degrees Fahrenheit and 550 degrees
Fahrenheit is .0071 and from formula (30),
1.5
H = ––––––––– = 211 feet.
.0071
Its diameter from curve in Fig. 33 is 96 inches if unlined, and 102 inches inside if
lined with masonry. The cross sectional area of the flue should be approximately 70
square feet at the point where the total amount of gas is to be handled, tapering to
the boiler farthest from the stack to a size which will depend upon the size of the
boiler units used.
Correction in Stack Sizes for Altitudes—It has ordinarily been assumed that a
stack height for altitude will be increased inversely as the ratio of the barometric
pressure at the altitude to that at sea level, and that the stack diameter will increase
inversely as the two-fifths power of this ratio. Such a relation has been based on the
flue temperatures at the maximum overload as 550 degrees Fahrenheit. The grate
surface equals 400 square feet.
For 50 per cent overload the combustion rate will be approximately 60 per cent
greater than this or 1.60 × 22 = 35 pounds per square foot of grate surface per hour.
The furnace draft required for the combustion rate, from the curve, Fig. 34, is 0.6
inch. The loss in the boiler will be 0.4 inch, in the flue 0.1 inch, and in the turns 2 ×
0.05 = 0.1 inch. The available draft required at the base of the stack is, therefore,
Inches
Boiler 0.4
Furnace 0.6
Flues 0.1
Turns 0.1
–––––
Total 1.2
[Pg 248]
Since the available draft is 80 per cent of the theoretical draft, this draft due to the
height required is 1.2 ÷ .8 = 1.5 inch.
The chimney constant for temperatures of 60 degrees Fahrenheit and 550 degrees
Fahrenheit is .0071 and from formula (30),
1.5
H = ––––––––– = 211 feet.
.0071
Its diameter from curve in Fig. 33 is 96 inches if unlined, and 102 inches inside if
lined with masonry. The cross sectional area of the flue should be approximately 70
square feet at the point where the total amount of gas is to be handled, tapering to
the boiler farthest from the stack to a size which will depend upon the size of the
boiler units used.
Correction in Stack Sizes for Altitudes—It has ordinarily been assumed that a
stack height for altitude will be increased inversely as the ratio of the barometric
pressure at the altitude to that at sea level, and that the stack diameter will increase
inversely as the two-fifths power of this ratio. Such a relation has been based on the
Page 341
assumption of constant draft measured in inches of water at the base of the stack for
a given rate of operation of the boilers, regardless of altitude.
If the assumption be made that boilers, flues and furnace remain the same, and
further that the increased velocity of a given weight of air passing through the
furnace at a higher altitude would have no effect on the combustion, the theory has
been advanced[53] that a different law applies.
Under the above assumptions, whenever a stack is working at its maximum
capacity at any altitude, the entire draft is utilized in overcoming the various
resistances, each of which is proportional to the square of the velocity of the gases.
Since boiler areas are fixed, all velocities may be related to a common velocity, say,
that within the stack, and all resistances may, therefore, be expressed as
proportional to the square of the chimney velocity. The total resistance to flow, in
terms of velocity head, may be expressed in terms of weight of a column of external
air, the numerical value of such head being independent of the barometric pressure.
Likewise the draft of a stack, expressed in height of column of external air, will be
numerically independent of the barometric pressure. It is evident, therefore, that if a
given boiler plant, with its stack operated with a fixed fuel, be transplanted from sea
level to an altitude, assuming the temperatures remain constant, the total draft head
measured in height of column of external air will be numerically constant. The
velocity of chimney gases will, therefore, remain the same at altitude as at sea level
and the weight of gases flowing per second with a fixed velocity will be
proportional to the atmospheric density or inversely proportional to the normal
barometric pressure.
To develop a given horse power requires a constant weight of chimney gas and air
for combustion. Hence, as the altitude is increased, the density is decreased and, for
the assumptions given above, the velocity through the furnace, the boiler passes,
breeching and flues must be correspondingly greater at altitude than at sea level.
The mean velocity, therefore, for a given boiler horse power and constant weight of
gases will be inversely proportional to the barometric pressure and the velocity
head measured in column of external air will be inversely proportional to the square
of the barometric pressure.
For stacks operating at altitude it is necessary not only to increase the height but
also the diameter, as there is an added resistance within the stack due to the added
[Pg 249] friction from the additional height. This frictional loss can be compensated
by a suitable increase in the diameter and when so compensated, it is evident that
on the assumptions as given, the chimney height would have to be increased at a
ratio inversely proportional to the square of the normal barometric pressure.
a given rate of operation of the boilers, regardless of altitude.
If the assumption be made that boilers, flues and furnace remain the same, and
further that the increased velocity of a given weight of air passing through the
furnace at a higher altitude would have no effect on the combustion, the theory has
been advanced[53] that a different law applies.
Under the above assumptions, whenever a stack is working at its maximum
capacity at any altitude, the entire draft is utilized in overcoming the various
resistances, each of which is proportional to the square of the velocity of the gases.
Since boiler areas are fixed, all velocities may be related to a common velocity, say,
that within the stack, and all resistances may, therefore, be expressed as
proportional to the square of the chimney velocity. The total resistance to flow, in
terms of velocity head, may be expressed in terms of weight of a column of external
air, the numerical value of such head being independent of the barometric pressure.
Likewise the draft of a stack, expressed in height of column of external air, will be
numerically independent of the barometric pressure. It is evident, therefore, that if a
given boiler plant, with its stack operated with a fixed fuel, be transplanted from sea
level to an altitude, assuming the temperatures remain constant, the total draft head
measured in height of column of external air will be numerically constant. The
velocity of chimney gases will, therefore, remain the same at altitude as at sea level
and the weight of gases flowing per second with a fixed velocity will be
proportional to the atmospheric density or inversely proportional to the normal
barometric pressure.
To develop a given horse power requires a constant weight of chimney gas and air
for combustion. Hence, as the altitude is increased, the density is decreased and, for
the assumptions given above, the velocity through the furnace, the boiler passes,
breeching and flues must be correspondingly greater at altitude than at sea level.
The mean velocity, therefore, for a given boiler horse power and constant weight of
gases will be inversely proportional to the barometric pressure and the velocity
head measured in column of external air will be inversely proportional to the square
of the barometric pressure.
For stacks operating at altitude it is necessary not only to increase the height but
also the diameter, as there is an added resistance within the stack due to the added
[Pg 249] friction from the additional height. This frictional loss can be compensated
by a suitable increase in the diameter and when so compensated, it is evident that
on the assumptions as given, the chimney height would have to be increased at a
ratio inversely proportional to the square of the normal barometric pressure.
Page 342
In designing a boiler for high altitudes, as already stated, the assumption is usually
made that a given grade of fuel will require the same draft measured in inches of
water at the boiler damper as at sea level, and this leads to making the stack height
inversely as the barometric pressures, instead of inversely as the square of the
barometric pressures. The correct height, no doubt, falls somewhere between the
two values as larger flues are usually used at the higher altitudes, whereas to obtain
the ratio of the squares, the flues must be the same size in each case, and again the
effect of an increased velocity of a given weight of air through the fire at a high
altitude, on the combustion, must be neglected. In making capacity tests with coal
fuel, no difference has been noted in the rates of combustion for a given draft
suction measured by a water column at high and low altitudes, and this would make
it appear that the correct height to use is more nearly that obtained by the inverse
ratio of the barometric readings than by the inverse ratio of the squares of the
barometric readings. If the assumption is made that the value falls midway between
the two formulae, the error in using a stack figured in the ordinary way by making
the height inversely proportional to the barometric readings would differ about 10
per cent in capacity at an altitude of 10,000 feet, which difference is well within the
probable variation of the size determined by different methods. It would, therefore,
appear that ample accuracy is obtained in all cases by simply making the height
inversely proportional to the barometric readings and increasing the diameter so
that the stacks used at high altitudes have the same frictional resistance as those
used at low altitudes, although, if desired, the stack may be made somewhat higher
at high altitudes than this rule calls for in order to be on the safe side.
TABLE 54 The
increas
STACK CAPACITIES, CORRECTION FACTORS FOR e of
ALTITUDES stack
R diamete
Altitude R2⁄5 r
Ratio Barometer
Height in Feet Normal Ratio Increase necessa
Reading R²
Above Barometer in Stack ry to
Sea Level to
Sea Level Diameter maintai
Altitude
0 30.00 1.000 1.000 1.000 n the
1000 28.88 1.039 1.079 1.015 same
friction
2000 27.80 1.079 1.064 1.030
loss is
3000 26.76 1.121 1.257 1.047
inversel
4000 25.76 1.165 1.356 1.063 y as the
5000 24.79 1.210 1.464 1.079 two-
6000 23.87 1.257 1.580 1.096 fifths
made that a given grade of fuel will require the same draft measured in inches of
water at the boiler damper as at sea level, and this leads to making the stack height
inversely as the barometric pressures, instead of inversely as the square of the
barometric pressures. The correct height, no doubt, falls somewhere between the
two values as larger flues are usually used at the higher altitudes, whereas to obtain
the ratio of the squares, the flues must be the same size in each case, and again the
effect of an increased velocity of a given weight of air through the fire at a high
altitude, on the combustion, must be neglected. In making capacity tests with coal
fuel, no difference has been noted in the rates of combustion for a given draft
suction measured by a water column at high and low altitudes, and this would make
it appear that the correct height to use is more nearly that obtained by the inverse
ratio of the barometric readings than by the inverse ratio of the squares of the
barometric readings. If the assumption is made that the value falls midway between
the two formulae, the error in using a stack figured in the ordinary way by making
the height inversely proportional to the barometric readings would differ about 10
per cent in capacity at an altitude of 10,000 feet, which difference is well within the
probable variation of the size determined by different methods. It would, therefore,
appear that ample accuracy is obtained in all cases by simply making the height
inversely proportional to the barometric readings and increasing the diameter so
that the stacks used at high altitudes have the same frictional resistance as those
used at low altitudes, although, if desired, the stack may be made somewhat higher
at high altitudes than this rule calls for in order to be on the safe side.
TABLE 54 The
increas
STACK CAPACITIES, CORRECTION FACTORS FOR e of
ALTITUDES stack
R diamete
Altitude R2⁄5 r
Ratio Barometer
Height in Feet Normal Ratio Increase necessa
Reading R²
Above Barometer in Stack ry to
Sea Level to
Sea Level Diameter maintai
Altitude
0 30.00 1.000 1.000 1.000 n the
1000 28.88 1.039 1.079 1.015 same
friction
2000 27.80 1.079 1.064 1.030
loss is
3000 26.76 1.121 1.257 1.047
inversel
4000 25.76 1.165 1.356 1.063 y as the
5000 24.79 1.210 1.464 1.079 two-
6000 23.87 1.257 1.580 1.096 fifths
Page 343
7000 22.97 1.306 1.706 1.113 power
8000 22.11 1.357 1.841 1.130 of the
9000 21.28 1.410 1.988 1.147 barome
10000 20.49 1.464 2.144 1.165 tric
pressur
e.
Table 54 gives the ratio of barometric readings of various altitudes to sea level,
values for the square of this ratio and values of the two-fifths power of this ratio.
These figures show that the altitude affects the height to a much greater extent than
the diameter and that practically no increase in diameter is necessary for altitudes
up to 3000 feet.
For high altitudes the increase in stack height necessary is, in some cases, [Pg 250]
such as to make the proportion of height to diameter impracticable. The method to
be recommended in overcoming, at least partially, the great increase in height
necessary at high altitudes is an increase in the grate surface of the boilers which
the stack serves, in this way reducing the combustion rate necessary to develop a
given power and hence the draft required for such combustion rate.
TABLE 55
STACK SIZES BY KENT’S FORMULA
ASSUMING 5 POUNDS OF COAL PER HORSE POWER
Side of
Height of Stack in Feet
Equiva-
Dia- Area Dia-
lent
meter Square 50 60 70 80 90 100 110 125 150 175 meter
Square
Inches Feet Inches
Stack
Commercial Horse Power
Inches
33 5.94 106 115 125 133 141 149 … … … … 30 33
36 7.07 129 141 152 163 173 182 … … … … 32 36
39 8.30 155 169 183 196 208 219 229 245 … … 35 39
42 9.62 183 200 216 231 245 258 271 289 316 … 38 42
48 12.57 246 269 290 311 330 348 365 389 426 460 43 48
54 15.90 318 348 376 402 427 449 472 503 551 595 48 54
60 19.64 400 437 473 505 536 565 593 632 692 748 54 60
66 23.76 490 537 580 620 658 694 728 776 849 918 59 66
72 28.27 591 646 698 747 792 835 876 934 023 1105 64 72
8000 22.11 1.357 1.841 1.130 of the
9000 21.28 1.410 1.988 1.147 barome
10000 20.49 1.464 2.144 1.165 tric
pressur
e.
Table 54 gives the ratio of barometric readings of various altitudes to sea level,
values for the square of this ratio and values of the two-fifths power of this ratio.
These figures show that the altitude affects the height to a much greater extent than
the diameter and that practically no increase in diameter is necessary for altitudes
up to 3000 feet.
For high altitudes the increase in stack height necessary is, in some cases, [Pg 250]
such as to make the proportion of height to diameter impracticable. The method to
be recommended in overcoming, at least partially, the great increase in height
necessary at high altitudes is an increase in the grate surface of the boilers which
the stack serves, in this way reducing the combustion rate necessary to develop a
given power and hence the draft required for such combustion rate.
TABLE 55
STACK SIZES BY KENT’S FORMULA
ASSUMING 5 POUNDS OF COAL PER HORSE POWER
Side of
Height of Stack in Feet
Equiva-
Dia- Area Dia-
lent
meter Square 50 60 70 80 90 100 110 125 150 175 meter
Square
Inches Feet Inches
Stack
Commercial Horse Power
Inches
33 5.94 106 115 125 133 141 149 … … … … 30 33
36 7.07 129 141 152 163 173 182 … … … … 32 36
39 8.30 155 169 183 196 208 219 229 245 … … 35 39
42 9.62 183 200 216 231 245 258 271 289 316 … 38 42
48 12.57 246 269 290 311 330 348 365 389 426 460 43 48
54 15.90 318 348 376 402 427 449 472 503 551 595 48 54
60 19.64 400 437 473 505 536 565 593 632 692 748 54 60
66 23.76 490 537 580 620 658 694 728 776 849 918 59 66
72 28.27 591 646 698 747 792 835 876 934 023 1105 64 72
Page 344
78 33.18 700 766 828 885 939 9901038 1107 1212 1310
70 78
84 38.48 818 896 968 1035 1098 1157 1214 1294 1418 1531
75 84
Side of
Height of Stack in Feet
Equiva-
Dia- Area Dia-
lent
meter Square 100 110 125 150 175 200 225 250 meter
Square
Inches Feet Inches
Stack
Commercial Horse Power
Inches
90 44.18 1338 1403 1496 1639 1770 18932008 2116 80 90
96 50.27 1532 1606 1713 1876 2027 21672298 2423 86 96
102 56.75 1739 1824 1944 2130 2300 24592609 2750 91 102
108 63.62 1959 2054 2190 2392 2592 27702939 3098 98 108
114 70.88 2192 2299 2451 2685 2900 31003288 3466 101 114
120 78.54 2438 2557 2726 2986 3226 34483657 3855 107 120
126 86.59 2697 2829 3016 3303 3568 38144046 4265 112 126
132 95.03 2970 3114 3321 3637 3929 42004455 4696 117 132
144 113.10 3554 3726 3973 4352 4701 50265331 5618 128 144
156 132.73 4190 4393 4684 5131 5542 59256285 6624 138 156
168 153.94 4878 5115 5454 5974 6454 68997318 7713 150 168
Kent’s Stack Tables—Table 55 gives, in convenient form for approximate work,
the sizes of stacks and the horse power of boilers which they will serve. This table
is a modification of Mr. William Kent’s stack table and is calculated from his
formula. Provided no unusual conditions are encountered, it is reliable for the
ordinary rates of combustion with bituminous coals. It is figured on a consumption
of 5 pounds of coal burned per hour per boiler horse power developed, this figure
giving a fairly liberal allowance for the use of poor coal and for a reasonable
overload. When the coal used is a low grade bituminous of the Middle or Western
States, it is strongly recommended that these sizes be increased materially, such an
increase being from 25 [Pg 251] to 60 per cent, depending upon the nature of the coal
and the capacity desired. For the coal burned per hour for any size stack given in
the table, the values should be multiplied by 5.
A convenient rule for large stacks, 200 feet high and over, is to provide 30 square
feet of cross sectional area per 1000 rated horse power.
Stacks for Oil Fuel—The requirements of stacks connected to boilers under which
oil fuel is burned are entirely different from those where coal is used. While more
attention has been paid to the matter of stack sizes for oil fuel in recent years, there
70 78
84 38.48 818 896 968 1035 1098 1157 1214 1294 1418 1531
75 84
Side of
Height of Stack in Feet
Equiva-
Dia- Area Dia-
lent
meter Square 100 110 125 150 175 200 225 250 meter
Square
Inches Feet Inches
Stack
Commercial Horse Power
Inches
90 44.18 1338 1403 1496 1639 1770 18932008 2116 80 90
96 50.27 1532 1606 1713 1876 2027 21672298 2423 86 96
102 56.75 1739 1824 1944 2130 2300 24592609 2750 91 102
108 63.62 1959 2054 2190 2392 2592 27702939 3098 98 108
114 70.88 2192 2299 2451 2685 2900 31003288 3466 101 114
120 78.54 2438 2557 2726 2986 3226 34483657 3855 107 120
126 86.59 2697 2829 3016 3303 3568 38144046 4265 112 126
132 95.03 2970 3114 3321 3637 3929 42004455 4696 117 132
144 113.10 3554 3726 3973 4352 4701 50265331 5618 128 144
156 132.73 4190 4393 4684 5131 5542 59256285 6624 138 156
168 153.94 4878 5115 5454 5974 6454 68997318 7713 150 168
Kent’s Stack Tables—Table 55 gives, in convenient form for approximate work,
the sizes of stacks and the horse power of boilers which they will serve. This table
is a modification of Mr. William Kent’s stack table and is calculated from his
formula. Provided no unusual conditions are encountered, it is reliable for the
ordinary rates of combustion with bituminous coals. It is figured on a consumption
of 5 pounds of coal burned per hour per boiler horse power developed, this figure
giving a fairly liberal allowance for the use of poor coal and for a reasonable
overload. When the coal used is a low grade bituminous of the Middle or Western
States, it is strongly recommended that these sizes be increased materially, such an
increase being from 25 [Pg 251] to 60 per cent, depending upon the nature of the coal
and the capacity desired. For the coal burned per hour for any size stack given in
the table, the values should be multiplied by 5.
A convenient rule for large stacks, 200 feet high and over, is to provide 30 square
feet of cross sectional area per 1000 rated horse power.
Stacks for Oil Fuel—The requirements of stacks connected to boilers under which
oil fuel is burned are entirely different from those where coal is used. While more
attention has been paid to the matter of stack sizes for oil fuel in recent years, there
Page 345
has not as yet been gathered the large amount of experimental data available for use
in designing coal stacks.
In the case of oil-fired boilers the loss of draft through the fuel bed is partially
eliminated. While there may be practically no loss through any checkerwork
admitting air to the furnace when a boiler is new, the areas for the air passage in this
checkerwork will in a short time be decreased, due to the silt which is present in
practically all fuel oil. The loss in draft through the boiler proper at a given rating
will be less than in the case of coal-fired boilers, this being due to a decrease in the
volume of the gases. Further, the action of the oil burner itself is to a certain extent
that of a forced draft. To offset this decrease in draft requirement, the temperature
of the gases entering the stack will be somewhat lower where oil is used than where
coal is used, and the draft that a stack of a given height would give, therefore,
decreases. The factors as given above, affecting as they do the intensity of the draft,
affect directly the height of the stack to be used.
As already stated, the volume of gases from oil-fired boilers being less than in the
case of coal, makes it evident that the area of stacks for oil fuel will be less than for
coal. It is assumed that these areas will vary directly as the volume of the gases to
be handled, and this volume for oil may be taken as approximately 60 per cent of
that for coal.
In designing stacks for oil fuel there are two features which must not be overlooked.
In coal-firing practice there is rarely danger of too much draft. In the burning of oil,
however, this may play an important part in the reduction of plant economy, the
influence of excessive draft being more apparent where the load on the plant may
be reduced at intervals. The reason for this is that, aside from a slight decrease in
temperature at reduced loads, the tendency, due to careless firing, is toward a
constant gas flow through the boiler regardless of the rate of operation, with the
corresponding increase of excess air at light loads. With excessive stack height,
economical operation at varying loads is almost impossible with hand control. With
automatic control, however, where stacks are necessarily high to take care of known
peaks, under lighter loads this economical operation becomes less difficult. For this
reason the question of designing a stack for a plant where the load is known to be
nearly a constant is easier than for a plant where the load will vary over a wide
range. While great care must be taken to avoid excessive draft, still more care must
be taken to assure a draft suction within all parts of the setting under any and all
conditions of operation. It is very easily possible to more than offset the economy
gained through low draft, by the losses due to setting deterioration, resulting from
such lack of suction. Under conditions where the suction is not sufficient to carry
off the products of combustion, the action of the heat on the setting brickwork will
in designing coal stacks.
In the case of oil-fired boilers the loss of draft through the fuel bed is partially
eliminated. While there may be practically no loss through any checkerwork
admitting air to the furnace when a boiler is new, the areas for the air passage in this
checkerwork will in a short time be decreased, due to the silt which is present in
practically all fuel oil. The loss in draft through the boiler proper at a given rating
will be less than in the case of coal-fired boilers, this being due to a decrease in the
volume of the gases. Further, the action of the oil burner itself is to a certain extent
that of a forced draft. To offset this decrease in draft requirement, the temperature
of the gases entering the stack will be somewhat lower where oil is used than where
coal is used, and the draft that a stack of a given height would give, therefore,
decreases. The factors as given above, affecting as they do the intensity of the draft,
affect directly the height of the stack to be used.
As already stated, the volume of gases from oil-fired boilers being less than in the
case of coal, makes it evident that the area of stacks for oil fuel will be less than for
coal. It is assumed that these areas will vary directly as the volume of the gases to
be handled, and this volume for oil may be taken as approximately 60 per cent of
that for coal.
In designing stacks for oil fuel there are two features which must not be overlooked.
In coal-firing practice there is rarely danger of too much draft. In the burning of oil,
however, this may play an important part in the reduction of plant economy, the
influence of excessive draft being more apparent where the load on the plant may
be reduced at intervals. The reason for this is that, aside from a slight decrease in
temperature at reduced loads, the tendency, due to careless firing, is toward a
constant gas flow through the boiler regardless of the rate of operation, with the
corresponding increase of excess air at light loads. With excessive stack height,
economical operation at varying loads is almost impossible with hand control. With
automatic control, however, where stacks are necessarily high to take care of known
peaks, under lighter loads this economical operation becomes less difficult. For this
reason the question of designing a stack for a plant where the load is known to be
nearly a constant is easier than for a plant where the load will vary over a wide
range. While great care must be taken to avoid excessive draft, still more care must
be taken to assure a draft suction within all parts of the setting under any and all
conditions of operation. It is very easily possible to more than offset the economy
gained through low draft, by the losses due to setting deterioration, resulting from
such lack of suction. Under conditions where the suction is not sufficient to carry
off the products of combustion, the action of the heat on the setting brickwork will
Page 346
cause its rapid failure.
[Pg 252]
7800 Horse-power Installation of Babcock & Wilcox Boilers, Equipped with
Babcock & Wilcox Chain Grate Stokers at the Metropolitan West Side
Elevated Ry. Co., Chicago, Ill.
[Pg 253]
TABLE 56 It becomes evident,
therefore, that the
STACK SIZES FOR OIL FUEL question of stack height
for oil-fired boilers is one
ADAPTED FROM C. R. WEYMOUTH’S TABLE which must be
(TRANS. A. S. M. E. VOL. 34) considered with the
Diameter Height in Feet Above Boiler Room Floor greatest of care. The
Inches 80 90 100 120 140 160 designer, on the one
33 161 206 233 270 306 315 hand, must guard against
the evils of excessive
36 208 253 295 331 363 387
draft with the view to
39 251 303 343 399 488 467 plant economy, and, on
42 295 359 403 474 521 557 the other, against the
[Pg 252]
7800 Horse-power Installation of Babcock & Wilcox Boilers, Equipped with
Babcock & Wilcox Chain Grate Stokers at the Metropolitan West Side
Elevated Ry. Co., Chicago, Ill.
[Pg 253]
TABLE 56 It becomes evident,
therefore, that the
STACK SIZES FOR OIL FUEL question of stack height
for oil-fired boilers is one
ADAPTED FROM C. R. WEYMOUTH’S TABLE which must be
(TRANS. A. S. M. E. VOL. 34) considered with the
Diameter Height in Feet Above Boiler Room Floor greatest of care. The
Inches 80 90 100 120 140 160 designer, on the one
33 161 206 233 270 306 315 hand, must guard against
the evils of excessive
36 208 253 295 331 363 387
draft with the view to
39 251 303 343 399 488 467 plant economy, and, on
42 295 359 403 474 521 557 the other, against the
Page 347
48 399 486 551 645 713 760 evils of lack of draft from
54 519 634 720 847 933 1000 the viewpoint of upkeep
60 657 800 913 1073 1193 1280 cost. Stacks for this work
66 813 993 1133 1333 1480 1593 should be proportioned to
72 980 1206 1373 1620 1807 1940 give ample draft for the
maximum overload that a
84 1373 1587 1933 2293 2560 2767
plant will be called upon
96 1833 2260 2587 3087 3453 3740 to carry, all conditions of
108 2367 2920 3347 4000 4483 4867 overload carefully
120 3060 3660 4207 5040 5660 6160 considered. At the same
time, where this
maximum overload is figured liberally enough to insure a draft suction within the
setting under all conditions, care must be taken against the installation of a stack
which would give more than this maximum draft.
Figures represent nominal rated horse power. Sizes as given good for 50 per cent
overloads.
Based on centrally located stacks, short direct flues and ordinary operating
efficiencies.
Table 56 gives the sizes of stacks, and horse power which they will serve for oil
fuel. This table is, in modified form, one calculated by Mr. C. R. Weymouth after an
exhaustive study of data pertaining to the subject, and will ordinarily give
satisfactory results.
Stacks for Blast Furnace Gas Work—For boilers burning blast furnace gas, as in
the case of oil-fired boilers, stack sizes as suited for coal firing will have to be
modified. The diameter of stacks for this work should be approximately the same as
for coal-fired boilers. The volume of gases would be slightly greater than from a
coal fire and would decrease the draft with a given stack, but such a decrease due to
volume is about offset by an increase due to somewhat higher temperatures in the
case of the blast furnace gases.
Records show that with this class of fuel 175 per cent of the rated capacity of a
boiler can be developed with a draft at the boiler damper of from 0.75 inch to 1.0
inch, and it is well to limit the height of stacks to one which will give this draft as a
maximum. A stack of proper diameter, 130 feet high above the ground, will produce
such a draft and this height should ordinarily not be exceeded. Until recently the
question of economy in boilers fired with blast furnace gas has not been considered,
but, aside from the economical standpoint, excessive draft should be guarded
against in order to lower the upkeep cost.
54 519 634 720 847 933 1000 the viewpoint of upkeep
60 657 800 913 1073 1193 1280 cost. Stacks for this work
66 813 993 1133 1333 1480 1593 should be proportioned to
72 980 1206 1373 1620 1807 1940 give ample draft for the
maximum overload that a
84 1373 1587 1933 2293 2560 2767
plant will be called upon
96 1833 2260 2587 3087 3453 3740 to carry, all conditions of
108 2367 2920 3347 4000 4483 4867 overload carefully
120 3060 3660 4207 5040 5660 6160 considered. At the same
time, where this
maximum overload is figured liberally enough to insure a draft suction within the
setting under all conditions, care must be taken against the installation of a stack
which would give more than this maximum draft.
Figures represent nominal rated horse power. Sizes as given good for 50 per cent
overloads.
Based on centrally located stacks, short direct flues and ordinary operating
efficiencies.
Table 56 gives the sizes of stacks, and horse power which they will serve for oil
fuel. This table is, in modified form, one calculated by Mr. C. R. Weymouth after an
exhaustive study of data pertaining to the subject, and will ordinarily give
satisfactory results.
Stacks for Blast Furnace Gas Work—For boilers burning blast furnace gas, as in
the case of oil-fired boilers, stack sizes as suited for coal firing will have to be
modified. The diameter of stacks for this work should be approximately the same as
for coal-fired boilers. The volume of gases would be slightly greater than from a
coal fire and would decrease the draft with a given stack, but such a decrease due to
volume is about offset by an increase due to somewhat higher temperatures in the
case of the blast furnace gases.
Records show that with this class of fuel 175 per cent of the rated capacity of a
boiler can be developed with a draft at the boiler damper of from 0.75 inch to 1.0
inch, and it is well to limit the height of stacks to one which will give this draft as a
maximum. A stack of proper diameter, 130 feet high above the ground, will produce
such a draft and this height should ordinarily not be exceeded. Until recently the
question of economy in boilers fired with blast furnace gas has not been considered,
but, aside from the economical standpoint, excessive draft should be guarded
against in order to lower the upkeep cost.
Page 348
Stacks should be made of sufficient height to produce a draft that will develop the
maximum capacity required, and this draft decreased proportionately for loads
under the maximum by damper regulation. The amount of gas fed to a boiler for
any given rating is a fixed quantity and if a draft in excess of that required for that
[Pg 254] particular rate of operation is supplied, economy is decreased and the wear
and tear on the setting is materially increased. Excess air which is drawn in, either
through or around the gas burners by an excessive draft, will decrease economy, as
in any other class of work. Again, as in oil-fired practice, it is essential on the other
hand that a suction be maintained within all parts of the setting, in this case not only
to provide against setting deterioration but to protect the operators from leakage of
gas which is disagreeable and may be dangerous. Aside from the intensity of the
draft, a poor mixture of the gas and air or a “laneing” action may lead to secondary
combustion with the possibility of dangerous explosions within the setting, may
cause a pulsating action within the setting, may increase the exit temperatures to a
point where there is danger of burning out damper boxes, and, in general, is hard on
the setting. It is highly essential, therefore, that the furnace be properly constructed
to meet the draft which will be available.
Stacks for Wood-fired Boilers—For boilers using wood as fuel, there is but little
data upon which to base stack sizes. The loss of draft through the bed of fuel will
vary over limits even wider than in the case of coal, for in this class of fuel the
moisture may run from practically 0.0 per cent to over 60 per cent, and the methods
of handling and firing are radically different for the different classes of wood (see
chapter on Wood-burning Furnaces). As economy is ordinarily of little importance,
high stack temperatures may be expected, and often unavoidably large quantities of
excess air are supplied due to the method of firing. In general, it may be stated that
for this class of fuel the diameter of stacks should be at least as great as for coal-
fired boilers, while the height may be slightly decreased. It is far the best plan in
designing a stack for boilers using wood fuel to consider each individual set of
conditions that exist, rather than try to follow any general rule.
One factor not to be overlooked in stacks for wood burning is their location. The
fine particles of this fuel are often carried unconsumed through the boiler, and
where the stack is not on top of the boiler, these particles may accumulate in the
base of the stack below the point at which the flue enters. Where there is any air
leakage through the base of such a stack, this fuel may become ignited and the stack
burned. Where there is a possibility of such action taking place, it is well to line the
stack with fire brick for a portion of its height.
Draft Gauges—The ordinary form of draft gauge, Fig. 35, which consists of a U-
tube, containing water, lacks sensitiveness in measuring such slight pressure
maximum capacity required, and this draft decreased proportionately for loads
under the maximum by damper regulation. The amount of gas fed to a boiler for
any given rating is a fixed quantity and if a draft in excess of that required for that
[Pg 254] particular rate of operation is supplied, economy is decreased and the wear
and tear on the setting is materially increased. Excess air which is drawn in, either
through or around the gas burners by an excessive draft, will decrease economy, as
in any other class of work. Again, as in oil-fired practice, it is essential on the other
hand that a suction be maintained within all parts of the setting, in this case not only
to provide against setting deterioration but to protect the operators from leakage of
gas which is disagreeable and may be dangerous. Aside from the intensity of the
draft, a poor mixture of the gas and air or a “laneing” action may lead to secondary
combustion with the possibility of dangerous explosions within the setting, may
cause a pulsating action within the setting, may increase the exit temperatures to a
point where there is danger of burning out damper boxes, and, in general, is hard on
the setting. It is highly essential, therefore, that the furnace be properly constructed
to meet the draft which will be available.
Stacks for Wood-fired Boilers—For boilers using wood as fuel, there is but little
data upon which to base stack sizes. The loss of draft through the bed of fuel will
vary over limits even wider than in the case of coal, for in this class of fuel the
moisture may run from practically 0.0 per cent to over 60 per cent, and the methods
of handling and firing are radically different for the different classes of wood (see
chapter on Wood-burning Furnaces). As economy is ordinarily of little importance,
high stack temperatures may be expected, and often unavoidably large quantities of
excess air are supplied due to the method of firing. In general, it may be stated that
for this class of fuel the diameter of stacks should be at least as great as for coal-
fired boilers, while the height may be slightly decreased. It is far the best plan in
designing a stack for boilers using wood fuel to consider each individual set of
conditions that exist, rather than try to follow any general rule.
One factor not to be overlooked in stacks for wood burning is their location. The
fine particles of this fuel are often carried unconsumed through the boiler, and
where the stack is not on top of the boiler, these particles may accumulate in the
base of the stack below the point at which the flue enters. Where there is any air
leakage through the base of such a stack, this fuel may become ignited and the stack
burned. Where there is a possibility of such action taking place, it is well to line the
stack with fire brick for a portion of its height.
Draft Gauges—The ordinary form of draft gauge, Fig. 35, which consists of a U-
tube, containing water, lacks sensitiveness in measuring such slight pressure
Page 349
differences as usually exist, and for that
reason gauges which multiply the draft
indications are more convenient and are
much used.
An instrument which has given excellent
results is one introduced by Mr. G. H.
Barrus, which multiplies the ordinary
indications as many times as desired. This is
illustrated in Fig. 36, and consists of a U-
Fig. 35. U-tube tube made of one-half inch glass, Fig. 36. Barrus
Draft Gauge surmounted by two larger tubes, or Draft Gauge
chambers, each having a diameter of 2½
inches. Two different liquids which will not
mix, and which are of different color, are used, usually alcohol colored red and a
certain grade of lubricating oil. [Pg 255] The movement of the line of demarcation is
proportional to the difference in the areas of the chambers and the U-tube
connecting them. The instrument is calibrated by comparison with the ordinary U-
tube gauge.
In the Ellison form of gauge the lower portion of the ordinary U-tube has been
replaced by a tube slightly inclined to the horizontal, as shown in Fig. 37. By this
arrangement any vertical motion in the right-hand upright tube causes a very much
greater travel of the liquid in the inclined tube, thus permitting extremely small
variation in the intensity of the draft to be read with facility.
The gauge is first leveled by means of the
small level attached to it, both legs being
open to the atmosphere. The liquid is then
adjusted until its meniscus rests at the zero
point on the left. The right-hand leg is then
connected to the source of draft by means
Fig. 37. Ellison Draft Gauge of a piece of rubber tubing. Under these
circumstances, a rise of level of one inch in
the right-hand vertical tube causes the
meniscus in the inclined tube to pass from
the point 0 to 1.0. The scale is divided into tenths of an inch, and the sub-divisions
are hundredths of an inch.
The makers furnish a non-drying oil for the liquid, usually a 300 degrees test
refined petroleum.
reason gauges which multiply the draft
indications are more convenient and are
much used.
An instrument which has given excellent
results is one introduced by Mr. G. H.
Barrus, which multiplies the ordinary
indications as many times as desired. This is
illustrated in Fig. 36, and consists of a U-
Fig. 35. U-tube tube made of one-half inch glass, Fig. 36. Barrus
Draft Gauge surmounted by two larger tubes, or Draft Gauge
chambers, each having a diameter of 2½
inches. Two different liquids which will not
mix, and which are of different color, are used, usually alcohol colored red and a
certain grade of lubricating oil. [Pg 255] The movement of the line of demarcation is
proportional to the difference in the areas of the chambers and the U-tube
connecting them. The instrument is calibrated by comparison with the ordinary U-
tube gauge.
In the Ellison form of gauge the lower portion of the ordinary U-tube has been
replaced by a tube slightly inclined to the horizontal, as shown in Fig. 37. By this
arrangement any vertical motion in the right-hand upright tube causes a very much
greater travel of the liquid in the inclined tube, thus permitting extremely small
variation in the intensity of the draft to be read with facility.
The gauge is first leveled by means of the
small level attached to it, both legs being
open to the atmosphere. The liquid is then
adjusted until its meniscus rests at the zero
point on the left. The right-hand leg is then
connected to the source of draft by means
Fig. 37. Ellison Draft Gauge of a piece of rubber tubing. Under these
circumstances, a rise of level of one inch in
the right-hand vertical tube causes the
meniscus in the inclined tube to pass from
the point 0 to 1.0. The scale is divided into tenths of an inch, and the sub-divisions
are hundredths of an inch.
The makers furnish a non-drying oil for the liquid, usually a 300 degrees test
refined petroleum.
Page 350
A very convenient form of the ordinary U-tube gauge is
known as the Peabody gauge, and it is shown in Fig. 38. This
is a small modified U-tube with a sliding scale between the
two legs of the U and with connections such that either a draft
suction or a draft pressure may be taken. The tops of the
sliding pieces extending across the tubes are placed at the
bottom of the meniscus and accurate readings in hundredths of
an inch are obtained by a vernier.
Fig. 38. Peabody
Draft Gauge
FOOTNOTES
[52] Results secured by this method will be approximately correct.
[53] See “Chimneys for Crude Oil”, C. R. Weymouth, Trans. A. S. M. E., Dec. 1912.
known as the Peabody gauge, and it is shown in Fig. 38. This
is a small modified U-tube with a sliding scale between the
two legs of the U and with connections such that either a draft
suction or a draft pressure may be taken. The tops of the
sliding pieces extending across the tubes are placed at the
bottom of the meniscus and accurate readings in hundredths of
an inch are obtained by a vernier.
Fig. 38. Peabody
Draft Gauge
FOOTNOTES
[52] Results secured by this method will be approximately correct.
[53] See “Chimneys for Crude Oil”, C. R. Weymouth, Trans. A. S. M. E., Dec. 1912.
Page 351
[Pg 256]
Page 352
EFFICIENCY AND CAPACITY OF BOILERS
Two of the most important operating factors entering into the consideration of
what constitutes a satisfactory boiler are its efficiency and capacity. The relation
of these factors to one another will be considered later under the selection of
boilers with reference to the work they are to accomplish. The present chapter
deals with the efficiency and capacity only with a view to making clear exactly
what is meant by these terms as applied to steam generating apparatus, together
with the methods of determining these factors by tests.
Efficiency—The term “efficiency”, specifically applied to a steam boiler, is the
ratio of heat absorbed by the boiler in the generation of steam to the total
amount of heat available in the medium utilized in securing such generation.
When this medium is a solid fuel, such as coal, it is impossible to secure the
complete combustion of the total amount fed to the boiler. A portion is bound to
drop through the grates where it becomes mixed with the ash and, remaining
unburned, produces no heat. Obviously, it is unfair to charge the boiler with the
failure to absorb the portion of available heat in the fuel that is wasted in this
way. On the other hand, the boiler user must pay for such waste and is justified
in charging it against the combined boiler and furnace. Due to this fact, the
efficiency of a boiler, as ordinarily stated, is in reality the combined efficiency of
the boiler, furnace and grate, and
Heat absorbed per pound of fuel
Efficiency of boiler,
= –––––––––––––––––––––––––––––––––––––––––––––––––– (31)
furnace and grate
Heat value per pound of fuel
The efficiency will be the same whether based on dry fuel or on fuel as fired,
including its content of moisture. For example: If the coal contained 3 per cent
of moisture, the efficiency would be
Heat absorbed per pound of fuel × 0.97
Efficiency of boiler,
= –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
furnace and grate
Heat value per pound of fuel × 0.97
where 0.97 cancels and the formula becomes (31).
Two of the most important operating factors entering into the consideration of
what constitutes a satisfactory boiler are its efficiency and capacity. The relation
of these factors to one another will be considered later under the selection of
boilers with reference to the work they are to accomplish. The present chapter
deals with the efficiency and capacity only with a view to making clear exactly
what is meant by these terms as applied to steam generating apparatus, together
with the methods of determining these factors by tests.
Efficiency—The term “efficiency”, specifically applied to a steam boiler, is the
ratio of heat absorbed by the boiler in the generation of steam to the total
amount of heat available in the medium utilized in securing such generation.
When this medium is a solid fuel, such as coal, it is impossible to secure the
complete combustion of the total amount fed to the boiler. A portion is bound to
drop through the grates where it becomes mixed with the ash and, remaining
unburned, produces no heat. Obviously, it is unfair to charge the boiler with the
failure to absorb the portion of available heat in the fuel that is wasted in this
way. On the other hand, the boiler user must pay for such waste and is justified
in charging it against the combined boiler and furnace. Due to this fact, the
efficiency of a boiler, as ordinarily stated, is in reality the combined efficiency of
the boiler, furnace and grate, and
Heat absorbed per pound of fuel
Efficiency of boiler,
= –––––––––––––––––––––––––––––––––––––––––––––––––– (31)
furnace and grate
Heat value per pound of fuel
The efficiency will be the same whether based on dry fuel or on fuel as fired,
including its content of moisture. For example: If the coal contained 3 per cent
of moisture, the efficiency would be
Heat absorbed per pound of fuel × 0.97
Efficiency of boiler,
= –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
furnace and grate
Heat value per pound of fuel × 0.97
where 0.97 cancels and the formula becomes (31).
Page 353
The heat supplied to the boiler is due to the combustible portion of fuel which is
actually burned, irrespective of what proportion of the total combustible fired
may be.[54] This fact has led to the use of a second efficiency basis on
combustible and which is called the efficiency of boiler and furnace[55], namely,
Heat absorbed per pound of combustible[56]
Efficiency of boiler
= ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– (32)
and furnace[55]
Heat value per pound of combustible
The efficiency so determined is used in comparing the relative performance of
boilers, irrespective of the type of grates used under them. If the loss of fuel
through the grates could be entirely overcome, the efficiencies obtained by (31)
and (32) would obviously be the same. Hence, in the case of liquid and gaseous
fuels, where there is practically no waste, these efficiencies are almost identical.
Pg 257]
As a matter of fact, it is extremely difficult, if not impossible, to determine the
actual efficiency of a boiler alone, as distinguished from the combined
efficiency of boiler, grate and furnace. This is due to the fact that the losses due
to excess air cannot be correctly attributed to either the boiler or the furnace, but
only to a combination of the complete apparatus. Attempts have been made to
devise methods for dividing the losses proportionately between the furnace and
the boiler, but such attempts are unsatisfactory and it is impossible to determine
the efficiency of a boiler apart from that of a furnace in such a way as to make
such determination of any practical value or in a way that might not lead to
endless dispute, were the question to arise in the case of a guaranteed efficiency.
From the boiler manufacturer’s standpoint, the only way of establishing an
efficiency that has any value when guarantees are to be met, is to require the
grate or stoker manufacturer to make certain guarantees as to minimum CO2,
maximum CO, and that the amount of combustible in the ash and blown away
with the flue gases does not exceed a certain percentage. With such a guarantee,
the efficiency should be based on the combined furnace and boiler.
General practice, however, has established the use of the efficiency based upon
combustible as representing the efficiency of the boiler alone. When such an
efficiency is used, its exact meaning, as pointed out on opposite page, should be
realized.
actually burned, irrespective of what proportion of the total combustible fired
may be.[54] This fact has led to the use of a second efficiency basis on
combustible and which is called the efficiency of boiler and furnace[55], namely,
Heat absorbed per pound of combustible[56]
Efficiency of boiler
= ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– (32)
and furnace[55]
Heat value per pound of combustible
The efficiency so determined is used in comparing the relative performance of
boilers, irrespective of the type of grates used under them. If the loss of fuel
through the grates could be entirely overcome, the efficiencies obtained by (31)
and (32) would obviously be the same. Hence, in the case of liquid and gaseous
fuels, where there is practically no waste, these efficiencies are almost identical.
Pg 257]
As a matter of fact, it is extremely difficult, if not impossible, to determine the
actual efficiency of a boiler alone, as distinguished from the combined
efficiency of boiler, grate and furnace. This is due to the fact that the losses due
to excess air cannot be correctly attributed to either the boiler or the furnace, but
only to a combination of the complete apparatus. Attempts have been made to
devise methods for dividing the losses proportionately between the furnace and
the boiler, but such attempts are unsatisfactory and it is impossible to determine
the efficiency of a boiler apart from that of a furnace in such a way as to make
such determination of any practical value or in a way that might not lead to
endless dispute, were the question to arise in the case of a guaranteed efficiency.
From the boiler manufacturer’s standpoint, the only way of establishing an
efficiency that has any value when guarantees are to be met, is to require the
grate or stoker manufacturer to make certain guarantees as to minimum CO2,
maximum CO, and that the amount of combustible in the ash and blown away
with the flue gases does not exceed a certain percentage. With such a guarantee,
the efficiency should be based on the combined furnace and boiler.
General practice, however, has established the use of the efficiency based upon
combustible as representing the efficiency of the boiler alone. When such an
efficiency is used, its exact meaning, as pointed out on opposite page, should be
realized.
Page 354
The computation of the efficiencies described on opposite page is best illustrated
by example.
Assume the following data to be determined from an actual boiler trial.
Steam pressure by gauge, 200 pounds.
Feed temperature, 180 degrees.
Total weight of coal fired, 17,500 pounds.
Percentage of moisture in coal, 3 per cent.
Total ash and refuse, 2396 pounds.
Total water evaporated, 153,543 pounds.
Per cent of moisture in steam, 0.5 per cent.
Heat value per pound of dry coal, 13,516.
Heat value per pound of combustible, 15,359.
The factor of evaporation for such a set of conditions is 1.0834. The actual
evaporation corrected for moisture in the steam is 152,775 and the equivalent
evaporation from and at 212 degrees is, therefore, 165,516 pounds.
The total dry fuel will be 17,500 × .97 = 16,975, and the evaporation per pound
of dry fuel from and at 212 degrees will be 165,516 ÷ 16,975 = 9.75 pounds.
The heat absorbed per pound of dry fuel will, therefore, be 9.75 × 970.4 = 9461
B. t. u. Hence, the efficiency by (31) will be 9461 ÷ 13,516 = 70.0 per cent. The
total combustible burned will be 16,975 - 2396 = 14,579, and the evaporation
from and at 212 degrees per pound of combustible will be 165,516 ÷ 14,579 =
11.35 pounds. Hence, the efficiency based on combustible from (32) will be
(11.35 × 97.04) ÷ 15,359 = 71.71.
For approximate results, a chart may be used to take the place of a computation
of efficiency. Fig. 39 shows such a chart based on the evaporation per pound of
dry fuel and the heat value per pound of dry fuel, from which efficiencies may
be read directly to within one-half of one per cent. It is used as follows: From
the intersection of the horizontal line, representing the evaporation per pound of
fuel, with the vertical line, representing the heat value per pound, the efficiency
is read directly from the diagonal scale of efficiencies. This chart may also be
used for efficiency based upon combustible when the evaporation from and at
212 degrees and the heat values are both given in terms of combustible.
[Pg 258]
by example.
Assume the following data to be determined from an actual boiler trial.
Steam pressure by gauge, 200 pounds.
Feed temperature, 180 degrees.
Total weight of coal fired, 17,500 pounds.
Percentage of moisture in coal, 3 per cent.
Total ash and refuse, 2396 pounds.
Total water evaporated, 153,543 pounds.
Per cent of moisture in steam, 0.5 per cent.
Heat value per pound of dry coal, 13,516.
Heat value per pound of combustible, 15,359.
The factor of evaporation for such a set of conditions is 1.0834. The actual
evaporation corrected for moisture in the steam is 152,775 and the equivalent
evaporation from and at 212 degrees is, therefore, 165,516 pounds.
The total dry fuel will be 17,500 × .97 = 16,975, and the evaporation per pound
of dry fuel from and at 212 degrees will be 165,516 ÷ 16,975 = 9.75 pounds.
The heat absorbed per pound of dry fuel will, therefore, be 9.75 × 970.4 = 9461
B. t. u. Hence, the efficiency by (31) will be 9461 ÷ 13,516 = 70.0 per cent. The
total combustible burned will be 16,975 - 2396 = 14,579, and the evaporation
from and at 212 degrees per pound of combustible will be 165,516 ÷ 14,579 =
11.35 pounds. Hence, the efficiency based on combustible from (32) will be
(11.35 × 97.04) ÷ 15,359 = 71.71.
For approximate results, a chart may be used to take the place of a computation
of efficiency. Fig. 39 shows such a chart based on the evaporation per pound of
dry fuel and the heat value per pound of dry fuel, from which efficiencies may
be read directly to within one-half of one per cent. It is used as follows: From
the intersection of the horizontal line, representing the evaporation per pound of
fuel, with the vertical line, representing the heat value per pound, the efficiency
is read directly from the diagonal scale of efficiencies. This chart may also be
used for efficiency based upon combustible when the evaporation from and at
212 degrees and the heat values are both given in terms of combustible.
[Pg 258]
Page 355
Fig. 39. Efficiency Chart. Calculated from Marks and Davis Tables
Diagonal Lines Represent Per Cent Efficiency
[Pg 259]
Boiler efficiencies will vary over a wide range, depending on a great variety of
factors and conditions. The highest efficiencies that have been secured with coal
are in the neighborhood of 82 per cent and from that point efficiencies are found
all the way down to below 50 per cent. Table 59[57] of tests of Babcock &
Wilcox boilers under varying conditions of fuel and operation will give an idea
of what may be obtained with proper operating conditions.
Diagonal Lines Represent Per Cent Efficiency
[Pg 259]
Boiler efficiencies will vary over a wide range, depending on a great variety of
factors and conditions. The highest efficiencies that have been secured with coal
are in the neighborhood of 82 per cent and from that point efficiencies are found
all the way down to below 50 per cent. Table 59[57] of tests of Babcock &
Wilcox boilers under varying conditions of fuel and operation will give an idea
of what may be obtained with proper operating conditions.
Page 356
The difference between the efficiency secured in any boiler trial and the perfect
efficiency, 100 per cent, includes the losses, some of which are unavoidable in
the present state of the art, arising in the conversion of the heat energy of the
coal to the heat energy in the steam. These losses may be classified as follows:
1st. Loss due to fuel dropped through the grate.
2nd. Loss due to unburned fuel which is carried by the draft, as small particles,
beyond the bridge wall into the setting or up the stack.
3rd. Loss due to the utilization of a portion of the heat in heating the moisture
contained in the fuel from the temperature of the atmosphere to 212 degrees; to
evaporate it at that temperature and to superheat the steam thus formed to the
temperature of the flue gases. This steam, of course, is first heated to the
temperature of the furnace but as it gives up a portion of this heat in passing
through the boiler, the superheating to the temperature of the exit gases is the
correct degree to be considered.
4th. Loss due to the water formed and by the burning of the hydrogen in the fuel
which must be evaporated and superheated as in item 3.
5th. Loss due to the superheating of the moisture in the air supplied from the
atmospheric temperature to the temperature of the flue gases.
6th. Loss due to the heating of the dry products of combustion to the
temperature of the flue gases.
7th. Loss due to the incomplete combustion of the fuel when the carbon is not
completely consumed but burns to CO instead of CO2. The CO passes out of the
stack unburned as a volatile gas capable of further combustion.
8th. Loss due to radiation of heat from the boiler and furnace settings.
Obviously a very elaborate test would have to be made were all of the above
items to be determined accurately. In ordinary practice it has become customary
to summarize these losses as follows, the methods of computing the losses being
given in each instance by a typical example:
(A) Loss due to the heating of moisture in the fuel from the atmospheric
temperature to 212 degrees, evaporate it at that temperature and superheat it to
the temperature of the flue gases. This in reality is the total heat above the
efficiency, 100 per cent, includes the losses, some of which are unavoidable in
the present state of the art, arising in the conversion of the heat energy of the
coal to the heat energy in the steam. These losses may be classified as follows:
1st. Loss due to fuel dropped through the grate.
2nd. Loss due to unburned fuel which is carried by the draft, as small particles,
beyond the bridge wall into the setting or up the stack.
3rd. Loss due to the utilization of a portion of the heat in heating the moisture
contained in the fuel from the temperature of the atmosphere to 212 degrees; to
evaporate it at that temperature and to superheat the steam thus formed to the
temperature of the flue gases. This steam, of course, is first heated to the
temperature of the furnace but as it gives up a portion of this heat in passing
through the boiler, the superheating to the temperature of the exit gases is the
correct degree to be considered.
4th. Loss due to the water formed and by the burning of the hydrogen in the fuel
which must be evaporated and superheated as in item 3.
5th. Loss due to the superheating of the moisture in the air supplied from the
atmospheric temperature to the temperature of the flue gases.
6th. Loss due to the heating of the dry products of combustion to the
temperature of the flue gases.
7th. Loss due to the incomplete combustion of the fuel when the carbon is not
completely consumed but burns to CO instead of CO2. The CO passes out of the
stack unburned as a volatile gas capable of further combustion.
8th. Loss due to radiation of heat from the boiler and furnace settings.
Obviously a very elaborate test would have to be made were all of the above
items to be determined accurately. In ordinary practice it has become customary
to summarize these losses as follows, the methods of computing the losses being
given in each instance by a typical example:
(A) Loss due to the heating of moisture in the fuel from the atmospheric
temperature to 212 degrees, evaporate it at that temperature and superheat it to
the temperature of the flue gases. This in reality is the total heat above the
Page 357
temperature of the air in the boiler room, in one pound of superheated steam at
atmospheric pressure at the temperature of the flue gases, multiplied by the
percentage of moisture in the fuel. As the total heat above the temperature of the
air would have to be computed in each instance, this loss is best expressed by:
(
Loss in B. t. u. per pound = W 212 - t + 970.4 + .47 (T - 212) ) (33)
Where W = per cent of moisture in coal,
t = the temperature of air in the boiler room, [Pg 260]
T [Pg 261] = temperature of the flue gases,
.47 = the specific heat of superheated steam at the atmospheric pressure
and at the flue gas temperature,
(212-t) = B. t. u. necessary to heat one pound of water from the temperature
of the boiler room to 212 degrees,
970.4 = B. t. u. necessary to evaporate one pound of water at 212 degrees
to steam at atmospheric pressure,
.47(T- = B. t. u. necessary to superheat one pound of steam at atmospheric
212) pressure from 212 degrees to temperature T.
atmospheric pressure at the temperature of the flue gases, multiplied by the
percentage of moisture in the fuel. As the total heat above the temperature of the
air would have to be computed in each instance, this loss is best expressed by:
(
Loss in B. t. u. per pound = W 212 - t + 970.4 + .47 (T - 212) ) (33)
Where W = per cent of moisture in coal,
t = the temperature of air in the boiler room, [Pg 260]
T [Pg 261] = temperature of the flue gases,
.47 = the specific heat of superheated steam at the atmospheric pressure
and at the flue gas temperature,
(212-t) = B. t. u. necessary to heat one pound of water from the temperature
of the boiler room to 212 degrees,
970.4 = B. t. u. necessary to evaporate one pound of water at 212 degrees
to steam at atmospheric pressure,
.47(T- = B. t. u. necessary to superheat one pound of steam at atmospheric
212) pressure from 212 degrees to temperature T.
Page 358
Portion of 15,000 Horse-power Installation of Babcock & Wilcox Boilers,
Equipped with Babcock & Wilcox Chain Grate Stokers at the
Northumberland, Pa., Plant of the Atlas Portland Cement Co. This
Company Operates a Total of 24,000 Horse Power of Babcock & Wilcox
Boilers in its Various Plants
(B) Loss due to heat carried away in the steam produced by the burning of the
hydrogen component of the fuel. In burning, one pound of hydrogen unites with
8 pounds of oxygen to form 9 pounds of steam. Following the reasoning of item
(A), therefore, this loss will be:
(
Loss in B. t. u. per pound = 9H (212 - t) + 970.4 + .47 (T - 212) ) (34)
Where H = the percentage by weight of hydrogen.
This item is frequently considered as a part of the unaccounted for loss, where
an ultimate analysis of the fuel is not given.
(C) Loss due to heat carried away by dry chimney gases. This is dependent upon
the weight of gas per pound of coal which may be determined by formula (16),
page 158.
Loss in B. t. u. per pound = (T - t) × .24 × W.
Where T and t have values as in (33),
.24 = specific heat of chimney gases,
W = weight of dry chimney gas per pound of coal.
(D) Loss due to incomplete combustion of the carbon content of the fuel, that is,
the burning of the carbon to CO instead of CO2.
10,150 CO
Loss in B. t. u. per pound = C × –––––––––––––––––– (35)
CO2 + CO
C = per cent of carbon in coal by ultimate analysis,
CO and CO2 = per cent of CO and CO2 by volume from flue gas analysis,
10,150 = the number of heat units generated by burning to CO2 one pound of
carbon contained in carbon monoxide.
Equipped with Babcock & Wilcox Chain Grate Stokers at the
Northumberland, Pa., Plant of the Atlas Portland Cement Co. This
Company Operates a Total of 24,000 Horse Power of Babcock & Wilcox
Boilers in its Various Plants
(B) Loss due to heat carried away in the steam produced by the burning of the
hydrogen component of the fuel. In burning, one pound of hydrogen unites with
8 pounds of oxygen to form 9 pounds of steam. Following the reasoning of item
(A), therefore, this loss will be:
(
Loss in B. t. u. per pound = 9H (212 - t) + 970.4 + .47 (T - 212) ) (34)
Where H = the percentage by weight of hydrogen.
This item is frequently considered as a part of the unaccounted for loss, where
an ultimate analysis of the fuel is not given.
(C) Loss due to heat carried away by dry chimney gases. This is dependent upon
the weight of gas per pound of coal which may be determined by formula (16),
page 158.
Loss in B. t. u. per pound = (T - t) × .24 × W.
Where T and t have values as in (33),
.24 = specific heat of chimney gases,
W = weight of dry chimney gas per pound of coal.
(D) Loss due to incomplete combustion of the carbon content of the fuel, that is,
the burning of the carbon to CO instead of CO2.
10,150 CO
Loss in B. t. u. per pound = C × –––––––––––––––––– (35)
CO2 + CO
C = per cent of carbon in coal by ultimate analysis,
CO and CO2 = per cent of CO and CO2 by volume from flue gas analysis,
10,150 = the number of heat units generated by burning to CO2 one pound of
carbon contained in carbon monoxide.
Page 359
(E) Loss due to unconsumed carbon in the ash (it being usually assumed that all
the combustible in the ash is carbon).
B. t. u. per
pound of
combustible
in the ash
Loss in B. t. u. per pound = per cent C × per cent ash × (36)
(usually
taken as
14,600 B. t.
u.)
TABLE 57
The loss incurred
DATA FROM WHICH HEAT BALANCE in this way is,
(TABLE 58) IS COMPUTED directly, the carbon
in the ash in
Steam Pressure by Gauge, Pounds 192
percentage terms
Temperature of Feed, Degrees Fahrenheit 180
of the total dry
Degrees of Superheat, Degrees Fahrenheit 115.2 coal fired,
Temperature of Boiler Room, Degrees Fahrenheit 81 multiplied by the
Temperature of Exit Gases, Degrees Fahrenheit 480 heat value of
Weight of Coal Used per Hour, Pounds 5714 carbon.
Moisture, Per Cent 1.83
Dry Coal Per Hour, Pounds 5609 To compute this
Ash and Refuse per Hour, Pounds 561 item, which is of
Ash and Refuse (of Dry Coal), Per Cent 10.00 great importance
in comparing the
Actual Evaporation per Hour, Pounds 57036
relative
C, Per Cent 78.57
performances of
H, Per Cent 5.60 different designs
O, Per Cent 7.02
Ultimate Analysis Dry Coal { N, Per Cent 1.11
of grates, an
analysis of the ash
Ash, Per Cent 6.52 must be available.
Sulphur, Per Cent 1.18
Heat Value per Pound Dry Coal, B. t. u. 14225 The other losses,
Heat Value per Pound Combustible, B. t. u. 15217 namely, items 2, 5
Combustible in Ash by Analysis, Per Cent 17.9 and 8 of the first
classification, are
Flue Gas Analysis CO2, Per Cent 14.33
{ O, Per Cent 4.54
ordinarily grouped
under one item, as
the combustible in the ash is carbon).
B. t. u. per
pound of
combustible
in the ash
Loss in B. t. u. per pound = per cent C × per cent ash × (36)
(usually
taken as
14,600 B. t.
u.)
TABLE 57
The loss incurred
DATA FROM WHICH HEAT BALANCE in this way is,
(TABLE 58) IS COMPUTED directly, the carbon
in the ash in
Steam Pressure by Gauge, Pounds 192
percentage terms
Temperature of Feed, Degrees Fahrenheit 180
of the total dry
Degrees of Superheat, Degrees Fahrenheit 115.2 coal fired,
Temperature of Boiler Room, Degrees Fahrenheit 81 multiplied by the
Temperature of Exit Gases, Degrees Fahrenheit 480 heat value of
Weight of Coal Used per Hour, Pounds 5714 carbon.
Moisture, Per Cent 1.83
Dry Coal Per Hour, Pounds 5609 To compute this
Ash and Refuse per Hour, Pounds 561 item, which is of
Ash and Refuse (of Dry Coal), Per Cent 10.00 great importance
in comparing the
Actual Evaporation per Hour, Pounds 57036
relative
C, Per Cent 78.57
performances of
H, Per Cent 5.60 different designs
O, Per Cent 7.02
Ultimate Analysis Dry Coal { N, Per Cent 1.11
of grates, an
analysis of the ash
Ash, Per Cent 6.52 must be available.
Sulphur, Per Cent 1.18
Heat Value per Pound Dry Coal, B. t. u. 14225 The other losses,
Heat Value per Pound Combustible, B. t. u. 15217 namely, items 2, 5
Combustible in Ash by Analysis, Per Cent 17.9 and 8 of the first
classification, are
Flue Gas Analysis CO2, Per Cent 14.33
{ O, Per Cent 4.54
ordinarily grouped
under one item, as
Page 360
CO, Per Cent 0.11 unaccounted for
N, Per Cent 81.02 losses, and are
obviously the
difference between 100 per cent and the sum of the heat utilized and the losses
accounted for as given above. Item 5, or the loss due to the moisture in the air,
may be readily computed, the moisture being determined from wet and dry bulb
thermometer readings, but it is usually disregarded as it is relatively small,
averaging, [Pg 262] say, one-fifth to one-half of one per cent. Lack of data may, of
course, make it necessary to include certain items of the second and ordinary
classification in this unaccounted for group.
A schedule of the losses as outlined, requires an evaporative test of the boiler, an
analysis of the flue gases, an ultimate analysis of the fuel, and either an ultimate
or proximate analysis of the ash. As the amount of unaccounted for losses forms
a basis on which to judge the accuracy of a test, such a schedule is called a “heat
balance”.
A heat balance is best illustrated by an example: Assume the data as given in
Table 57 to be secured in an actual boiler test.
From this data the factor of evaporation is 1.1514 and the evaporation per hour
from and at 212 degrees is 65,671 pounds. Hence the evaporation from and at
212 degrees per pound of dry coal is 65,671 ÷ 5609 = 11.71 pounds. The
efficiency of boiler, furnace and grate is:
( 11.71 × 970.4) ÷ 14,225 = 79.88 per cent.
The heat losses are:
(A) Loss due to moisture in coal,
(
= .01831 (212 - 81) + 970.4 + .47 (480 - 212) )
= 22. B. t. u.,
= 0.15 per cent.
(B) The loss due to the burning of hydrogen:
N, Per Cent 81.02 losses, and are
obviously the
difference between 100 per cent and the sum of the heat utilized and the losses
accounted for as given above. Item 5, or the loss due to the moisture in the air,
may be readily computed, the moisture being determined from wet and dry bulb
thermometer readings, but it is usually disregarded as it is relatively small,
averaging, [Pg 262] say, one-fifth to one-half of one per cent. Lack of data may, of
course, make it necessary to include certain items of the second and ordinary
classification in this unaccounted for group.
A schedule of the losses as outlined, requires an evaporative test of the boiler, an
analysis of the flue gases, an ultimate analysis of the fuel, and either an ultimate
or proximate analysis of the ash. As the amount of unaccounted for losses forms
a basis on which to judge the accuracy of a test, such a schedule is called a “heat
balance”.
A heat balance is best illustrated by an example: Assume the data as given in
Table 57 to be secured in an actual boiler test.
From this data the factor of evaporation is 1.1514 and the evaporation per hour
from and at 212 degrees is 65,671 pounds. Hence the evaporation from and at
212 degrees per pound of dry coal is 65,671 ÷ 5609 = 11.71 pounds. The
efficiency of boiler, furnace and grate is:
( 11.71 × 970.4) ÷ 14,225 = 79.88 per cent.
The heat losses are:
(A) Loss due to moisture in coal,
(
= .01831 (212 - 81) + 970.4 + .47 (480 - 212) )
= 22. B. t. u.,
= 0.15 per cent.
(B) The loss due to the burning of hydrogen:
Page 361
(
= 9 × .0560 (212 - 81) + 970.4 + .47 (480 - 212) )
= 618 B. t. u.,
= 4.34 per cent.
(C) To compute the loss in the heat carried away by dry chimney gases per
pound of coal the weight of such gases must be first determined. This weight per
pound of coal is:
11CO2 + 8O + 7(CO + N)
( –––––––––––––––––––––––––––––––––––––––––––
3(CO2+CO)
)C
[Pg 263]
where CO2, O, CO and H are the percentage by volume as determined by the
flue gas analysis and C is the percentage by weight of carbon in the dry fuel.
Hence the weight of gas per pound of coal will be,
11 × 14.33 + 8 × 4.54 + 7(0.11 + 81.02)
( ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
3(14.33 + 0.11)
) × 78.57 = 13.7 pounds.
Therefore the loss of heat in the dry gases carried up the chimney =
13.7 × 0.24(480 - 81) = 1311 B. t. u.,
= 9.22 per cent.
(D) The loss due to incomplete combustion as evidenced by the presence of CO
in the flue gas analysis is:
0.11
––––––––––––––––––––– × 78.57 × 10,150 = 61. B. t. u.,
14.33 + 0.11
= .43 per cent.
(E) The loss due to unconsumed carbon in the ash:
= 9 × .0560 (212 - 81) + 970.4 + .47 (480 - 212) )
= 618 B. t. u.,
= 4.34 per cent.
(C) To compute the loss in the heat carried away by dry chimney gases per
pound of coal the weight of such gases must be first determined. This weight per
pound of coal is:
11CO2 + 8O + 7(CO + N)
( –––––––––––––––––––––––––––––––––––––––––––
3(CO2+CO)
)C
[Pg 263]
where CO2, O, CO and H are the percentage by volume as determined by the
flue gas analysis and C is the percentage by weight of carbon in the dry fuel.
Hence the weight of gas per pound of coal will be,
11 × 14.33 + 8 × 4.54 + 7(0.11 + 81.02)
( ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
3(14.33 + 0.11)
) × 78.57 = 13.7 pounds.
Therefore the loss of heat in the dry gases carried up the chimney =
13.7 × 0.24(480 - 81) = 1311 B. t. u.,
= 9.22 per cent.
(D) The loss due to incomplete combustion as evidenced by the presence of CO
in the flue gas analysis is:
0.11
––––––––––––––––––––– × 78.57 × 10,150 = 61. B. t. u.,
14.33 + 0.11
= .43 per cent.
(E) The loss due to unconsumed carbon in the ash:
Page 362
The analysis of the ash showed 17.9 per cent to be combustible matter, all of
which is assumed to be carbon. The test showed 10.00 of the total dry fuel fired
to be ash. Hence 10.00×.179 = 1.79 per cent of the total fuel represents the
proportion of this total unconsumed in the ash and the loss due to this cause is
1.79 per cent × 14,600 = 261 B. t. u.,
= 1.83 per cent.
The heat absorbed by the boilers per pound of dry fuel is 11.71×970.4 = 11,363
B. t. u. This quantity plus losses (A), (B), (C), (D) and (E), or
11,363+22+618+1311+61+261 = 13,636 B. t. u. accounted for. The heat value of
the coal, 14,225 B. t. u., less 13,636 B. t. u., leaves 589 B. t. u., unaccounted for
losses, or 4.15 per cent.
The heat balance should be arranged in the form indicated by Table 58.
TABLE 58
HEAT BALANCE
B. T. U. PER POUND DRY COAL 14,225
B. t. u. Per Cent
Heat absorbed by Boiler 11,363 79.88
Loss due to Evaporation of Moisture in Fuel 22 0.15
Loss due to Moisture formed by Burning of Hydrogen 618 4.34
Loss due to Heat carried away in Dry Chimney Gases 1311 9.22
Loss due to Incomplete Combustion of Carbon 61 0.43
Loss due to Unconsumed Carbon in the Ash 261 1.83
Loss due to Radiation and Unaccounted Losses 589 4.15
Total 14,225 100.00
Application of Heat Balance—A heat balance should be made in connection
with any boiler trial on which sufficient data for its computation has been
obtained. This is particularly true where the boiler performance has been
considered unsatisfactory. The distribution of the heat is thus determined and
any extraordinary loss may be detected. Where accurate data for computing such
a heat balance is not [Pg 264] available, such a calculation based on certain
assumptions is sometimes sufficient to indicate unusual losses.
which is assumed to be carbon. The test showed 10.00 of the total dry fuel fired
to be ash. Hence 10.00×.179 = 1.79 per cent of the total fuel represents the
proportion of this total unconsumed in the ash and the loss due to this cause is
1.79 per cent × 14,600 = 261 B. t. u.,
= 1.83 per cent.
The heat absorbed by the boilers per pound of dry fuel is 11.71×970.4 = 11,363
B. t. u. This quantity plus losses (A), (B), (C), (D) and (E), or
11,363+22+618+1311+61+261 = 13,636 B. t. u. accounted for. The heat value of
the coal, 14,225 B. t. u., less 13,636 B. t. u., leaves 589 B. t. u., unaccounted for
losses, or 4.15 per cent.
The heat balance should be arranged in the form indicated by Table 58.
TABLE 58
HEAT BALANCE
B. T. U. PER POUND DRY COAL 14,225
B. t. u. Per Cent
Heat absorbed by Boiler 11,363 79.88
Loss due to Evaporation of Moisture in Fuel 22 0.15
Loss due to Moisture formed by Burning of Hydrogen 618 4.34
Loss due to Heat carried away in Dry Chimney Gases 1311 9.22
Loss due to Incomplete Combustion of Carbon 61 0.43
Loss due to Unconsumed Carbon in the Ash 261 1.83
Loss due to Radiation and Unaccounted Losses 589 4.15
Total 14,225 100.00
Application of Heat Balance—A heat balance should be made in connection
with any boiler trial on which sufficient data for its computation has been
obtained. This is particularly true where the boiler performance has been
considered unsatisfactory. The distribution of the heat is thus determined and
any extraordinary loss may be detected. Where accurate data for computing such
a heat balance is not [Pg 264] available, such a calculation based on certain
assumptions is sometimes sufficient to indicate unusual losses.
Page 363
The largest loss is ordinarily due to the chimney gases, which depends directly
upon the weight of the gas and its temperature leaving the boiler. As pointed out
in the chapter on flue gas analysis, the lower limit of the weight of gas is fixed
by the minimum air supplied with which complete combustion may be obtained.
As shown, where this supply is unduly small, the loss caused by burning the
carbon to CO instead of to CO2 more than offsets the gain in decreasing the
weight of gas.
The lower limit of the stack temperature, as has been shown in the chapter on
draft, is more or less fixed by the temperature necessary to create sufficient draft
suction for good combustion. With natural draft, this lower limit is probably
between 400 and 450 degrees.
Capacity—Before the capacity of a boiler is considered, it is necessary to define
the basis to which such a term may be referred. Such a basis is the so-called
boiler horse power.
The unit of motive power in general use among steam engineers is the “horse
power” which is equivalent to 33,000 foot pounds per minute. Stationary boilers
are at the present time rated in horse power, though such a basis of rating may
lead and has often led to a misunderstanding. Work, as the term is used in
mechanics, is the overcoming of resistance through space, while power is the
rate of work or the amount done per unit of time. As the operation of a boiler in
service implies no motion, it can produce no power in the sense of the term as
understood in mechanics. Its operation is the generation of steam, which acts as
a medium to convey the energy of the fuel which is in the form of heat to a
prime mover in which that heat energy is converted into energy of motion or
work, and power is developed.
If all engines developed the same amount of power from an equal amount of
heat, a boiler might be designated as one having a definite horse power,
dependent upon the amount of engine horse power its steam would develop.
Such a statement of the rating of boilers, though it would still be inaccurate, if
the term is considered in its mechanical sense, could, through custom, be
interpreted to indicate that a boiler was of the exact capacity required to generate
the steam necessary to develop a definite amount of horse power in an engine.
Such a basis of rating, however, is obviously impossible when the fact is
considered that the amount of steam necessary to produce the same power in
prime movers of different types and sizes varies over very wide limits.
upon the weight of the gas and its temperature leaving the boiler. As pointed out
in the chapter on flue gas analysis, the lower limit of the weight of gas is fixed
by the minimum air supplied with which complete combustion may be obtained.
As shown, where this supply is unduly small, the loss caused by burning the
carbon to CO instead of to CO2 more than offsets the gain in decreasing the
weight of gas.
The lower limit of the stack temperature, as has been shown in the chapter on
draft, is more or less fixed by the temperature necessary to create sufficient draft
suction for good combustion. With natural draft, this lower limit is probably
between 400 and 450 degrees.
Capacity—Before the capacity of a boiler is considered, it is necessary to define
the basis to which such a term may be referred. Such a basis is the so-called
boiler horse power.
The unit of motive power in general use among steam engineers is the “horse
power” which is equivalent to 33,000 foot pounds per minute. Stationary boilers
are at the present time rated in horse power, though such a basis of rating may
lead and has often led to a misunderstanding. Work, as the term is used in
mechanics, is the overcoming of resistance through space, while power is the
rate of work or the amount done per unit of time. As the operation of a boiler in
service implies no motion, it can produce no power in the sense of the term as
understood in mechanics. Its operation is the generation of steam, which acts as
a medium to convey the energy of the fuel which is in the form of heat to a
prime mover in which that heat energy is converted into energy of motion or
work, and power is developed.
If all engines developed the same amount of power from an equal amount of
heat, a boiler might be designated as one having a definite horse power,
dependent upon the amount of engine horse power its steam would develop.
Such a statement of the rating of boilers, though it would still be inaccurate, if
the term is considered in its mechanical sense, could, through custom, be
interpreted to indicate that a boiler was of the exact capacity required to generate
the steam necessary to develop a definite amount of horse power in an engine.
Such a basis of rating, however, is obviously impossible when the fact is
considered that the amount of steam necessary to produce the same power in
prime movers of different types and sizes varies over very wide limits.
Page 364
To do away with the confusion resulting from an indefinite meaning of the term
boiler horse power, the Committee of Judges in charge of the boiler trials at the
Centennial Exposition, 1876, at Philadelphia, ascertained that a good engine of
the type prevailing at the time required approximately 30 pounds of steam per
hour per horse power developed. In order to establish a relation between the
engine power and the size of a boiler required to develop that power, they
recommended that an evaporation of 30 pounds of water from an initial
temperature of 100 degrees Fahrenheit to steam at 70 pounds gauge pressure be
considered as one boiler horse power. This recommendation has been generally
accepted by American engineers as a standard, and when the term boiler horse
power is used in connection with stationary boilers[58] [Pg 265] throughout this
country,[59] without special definition, it is understood to have this meaning.
Inasmuch as an equivalent evaporation from and at 212 degrees Fahrenheit is the
generally accepted basis of comparison[60], it is now customary to consider the
standard boiler horse power as recommended by the Centennial Exposition
Committee, in terms of equivalent evaporation from and at 212 degrees. This
will be 30 pounds multiplied by the factor of evaporation for 70 pounds gauge
pressure and 100 degrees feed temperature, or 1.1494. 30 × 1.1494 = 34.482, or
approximately 34.5 pounds. Hence, one boiler horse power is equal to an
evaporation of 34.5 pounds of water per hour from and at 212 degrees
Fahrenheit. The term boiler horse power, therefore, is clearly a measure of
evaporation and not of power.
A method of basing the horse power rating of a boiler adopted by boiler
manufacturers is that of heating surfaces. Such a method is absolutely arbitrary
and changes in no way the definition of a boiler horse power just given. It is
simply a statement by the manufacturer that his product, under ordinary
operating conditions or conditions which may be specified, will evaporate 34.5
pounds of water from and at 212 degrees per definite amount of heating surface
provided. The amount of heating surface that has been considered by
manufacturers capable of evaporating 34.5 pounds from and at 212 degrees per
hour has changed from time to time as the art has progressed. At the present time
10 square feet of heating surface is ordinarily considered the equivalent of one
boiler horse power among manufacturers of stationary boilers. In view of the
arbitrary nature of such rating and of the widely varying rates of evaporation
possible per square foot of heating surface with different boilers and different
operating conditions, such a basis of rating has in reality no particular bearing on
the question of horse power and should be considered merely as a convenience.
boiler horse power, the Committee of Judges in charge of the boiler trials at the
Centennial Exposition, 1876, at Philadelphia, ascertained that a good engine of
the type prevailing at the time required approximately 30 pounds of steam per
hour per horse power developed. In order to establish a relation between the
engine power and the size of a boiler required to develop that power, they
recommended that an evaporation of 30 pounds of water from an initial
temperature of 100 degrees Fahrenheit to steam at 70 pounds gauge pressure be
considered as one boiler horse power. This recommendation has been generally
accepted by American engineers as a standard, and when the term boiler horse
power is used in connection with stationary boilers[58] [Pg 265] throughout this
country,[59] without special definition, it is understood to have this meaning.
Inasmuch as an equivalent evaporation from and at 212 degrees Fahrenheit is the
generally accepted basis of comparison[60], it is now customary to consider the
standard boiler horse power as recommended by the Centennial Exposition
Committee, in terms of equivalent evaporation from and at 212 degrees. This
will be 30 pounds multiplied by the factor of evaporation for 70 pounds gauge
pressure and 100 degrees feed temperature, or 1.1494. 30 × 1.1494 = 34.482, or
approximately 34.5 pounds. Hence, one boiler horse power is equal to an
evaporation of 34.5 pounds of water per hour from and at 212 degrees
Fahrenheit. The term boiler horse power, therefore, is clearly a measure of
evaporation and not of power.
A method of basing the horse power rating of a boiler adopted by boiler
manufacturers is that of heating surfaces. Such a method is absolutely arbitrary
and changes in no way the definition of a boiler horse power just given. It is
simply a statement by the manufacturer that his product, under ordinary
operating conditions or conditions which may be specified, will evaporate 34.5
pounds of water from and at 212 degrees per definite amount of heating surface
provided. The amount of heating surface that has been considered by
manufacturers capable of evaporating 34.5 pounds from and at 212 degrees per
hour has changed from time to time as the art has progressed. At the present time
10 square feet of heating surface is ordinarily considered the equivalent of one
boiler horse power among manufacturers of stationary boilers. In view of the
arbitrary nature of such rating and of the widely varying rates of evaporation
possible per square foot of heating surface with different boilers and different
operating conditions, such a basis of rating has in reality no particular bearing on
the question of horse power and should be considered merely as a convenience.
Page 365
The whole question of a unit of boiler capacity has been widely discussed with a
view to the adoption of a standard to which there would appear to be a more
rational and definite basis. Many suggestions have been offered as to such a
basis but up to the present time there has been none which has met with
universal approval or which would appear likely to be generally adopted.
With the meaning of boiler horse power as given above, that is, a measure of
evaporation, it is evident that the capacity of a boiler is a measure of the power it
can develop expressed in boiler horse power. Since it is necessary, as stated, for
boiler manufacturers to adopt a standard for reasons of convenience in selling,
the horse power for which a boiler is sold is known as its normal rated capacity.
The efficiency of a boiler and the maximum capacity it will develop can be
determined accurately only by a boiler test. The standard methods of conducting
such tests are given on the following pages, these methods being the
recommendations of the Power Test Committee of the American Society of
Mechanical Engineers brought out in 1913.[61] Certain changes have been made
to incorporate in the boiler code such portions of the “Instructions Regarding
Tests in General” as apply to boiler testing. Methods of calculation and such
matter as are treated in other portions of the book have been omitted from the
code as noted.
[Pg 266]
view to the adoption of a standard to which there would appear to be a more
rational and definite basis. Many suggestions have been offered as to such a
basis but up to the present time there has been none which has met with
universal approval or which would appear likely to be generally adopted.
With the meaning of boiler horse power as given above, that is, a measure of
evaporation, it is evident that the capacity of a boiler is a measure of the power it
can develop expressed in boiler horse power. Since it is necessary, as stated, for
boiler manufacturers to adopt a standard for reasons of convenience in selling,
the horse power for which a boiler is sold is known as its normal rated capacity.
The efficiency of a boiler and the maximum capacity it will develop can be
determined accurately only by a boiler test. The standard methods of conducting
such tests are given on the following pages, these methods being the
recommendations of the Power Test Committee of the American Society of
Mechanical Engineers brought out in 1913.[61] Certain changes have been made
to incorporate in the boiler code such portions of the “Instructions Regarding
Tests in General” as apply to boiler testing. Methods of calculation and such
matter as are treated in other portions of the book have been omitted from the
code as noted.
[Pg 266]
Page 366
Portion of 2600 Horse-power Installation of Babcock & Wilcox Boilers,
Equipped with Babcock & Wilcox Chain Grate Stokers at the Peter
Schoenhofen Brewing Co., Chicago, Ill.
1. OBJECT [Pg 267]
Ascertain the specific object of the test, and keep this in view not only in the
work of preparation, but also during the progress of the test, and do not let it be
obscured by devoting too close attention to matters of minor importance.
Whatever the object of the test may be, accuracy and reliability must underlie
the work from beginning to end.
Equipped with Babcock & Wilcox Chain Grate Stokers at the Peter
Schoenhofen Brewing Co., Chicago, Ill.
1. OBJECT [Pg 267]
Ascertain the specific object of the test, and keep this in view not only in the
work of preparation, but also during the progress of the test, and do not let it be
obscured by devoting too close attention to matters of minor importance.
Whatever the object of the test may be, accuracy and reliability must underlie
the work from beginning to end.
Page 367
If questions of fulfillment of contract are involved, there should be a clear
understanding between all the parties, preferably in writing, as to the operating
conditions which should obtain during the trial, and as to the methods of testing
to be followed, unless these are already expressed in the contract itself.
Among the many objects of performance tests, the following may be noted:
Determination of capacity and efficiency, and how these compare with
standard or guaranteed results.
Comparison of different conditions or methods of operation.
Determination of the cause of either inferior or superior results.
Comparison of different kinds of fuel.
Determination of the effect of changes of design or proportion upon
capacity or efficiency, etc.
2. PREPARATIONS
(A) Dimensions:
Measure the dimensions of the principal parts of the apparatus to be tested, so
far as they bear on the objects in view, or determine these from correct working
drawings. Notice the general features of the same, both exterior and interior, and
make sketches, if needed, to show unusual points of design.
The dimensions of the heating surfaces of boilers and superheaters to be
found are those of surfaces in contact with the fire or hot gases. The
submerged surfaces in boilers at the mean water level should be considered
as water-heating surfaces, and other surfaces which are exposed to the
gases as superheating surfaces.
(B) Examination of Plant:
Make a thorough examination of the physical condition of all parts of the plant
or apparatus which concern the object in view, and record the conditions found,
together with any points in the matter of operation which bear thereon.
understanding between all the parties, preferably in writing, as to the operating
conditions which should obtain during the trial, and as to the methods of testing
to be followed, unless these are already expressed in the contract itself.
Among the many objects of performance tests, the following may be noted:
Determination of capacity and efficiency, and how these compare with
standard or guaranteed results.
Comparison of different conditions or methods of operation.
Determination of the cause of either inferior or superior results.
Comparison of different kinds of fuel.
Determination of the effect of changes of design or proportion upon
capacity or efficiency, etc.
2. PREPARATIONS
(A) Dimensions:
Measure the dimensions of the principal parts of the apparatus to be tested, so
far as they bear on the objects in view, or determine these from correct working
drawings. Notice the general features of the same, both exterior and interior, and
make sketches, if needed, to show unusual points of design.
The dimensions of the heating surfaces of boilers and superheaters to be
found are those of surfaces in contact with the fire or hot gases. The
submerged surfaces in boilers at the mean water level should be considered
as water-heating surfaces, and other surfaces which are exposed to the
gases as superheating surfaces.
(B) Examination of Plant:
Make a thorough examination of the physical condition of all parts of the plant
or apparatus which concern the object in view, and record the conditions found,
together with any points in the matter of operation which bear thereon.
Page 368
In boilers, examine for leakage of tubes and riveted or other metal joints.
Note the condition of brick furnaces, grates and baffles. Examine brick
walls and cleaning doors for air leaks, either by shutting the damper and
observing the escaping smoke or by candle-flame test. Determine the
condition of heating surfaces with reference to exterior deposits of soot and
interior deposits of mud or scale.
See that the steam main is so arranged that condensed and entrained water
cannot flow back into the boiler.
If the object of the test is to determine the highest efficiency or capacity
obtainable, any physical defects, or defects of operation, tending to make the
result unfavorable should first be remedied; all foul parts being cleaned, and the
whole put in first-class condition. If, on the other hand, the object is to ascertain
the performance under existing conditions, no such preparation is either required
or desired.
(C) General Precautions against Leakage:
In steam tests make sure that there is no leakage through blow-offs, drips, etc.,
or any steam or water connections of the plant or apparatus undergoing test,
which [Pg 268] would in any way affect the results. All such connections should
be blanked off, or satisfactory assurance should be obtained that there is leakage
neither out nor in. This is a most important matter, and no assurance should be
considered satisfactory unless it is susceptible of absolute demonstration.
3. FUEL
Determine the character of fuel to be used.[62] For tests of maximum efficiency
or capacity of the boiler to compare with other boilers, the coal should be of
some kind which is commercially regarded as a standard for the locality where
the test is made.
In the Eastern States the standards thus regarded for semi-bituminous coals
are Pocahontas (Va. and W. Va.) and New River (W. Va.); for anthracite
coals those of the No. 1 buckwheat size, fresh-mined, containing not over
13 per cent ash by analysis; and for bituminous coals, Youghiogheny and
Pittsburgh coals. In some sections east of the Allegheny Mountains the
semi-bituminous Clearfield (Pa.) and Cumberland (Md.) are also
considered as standards. These coals when of good quality possess the
Note the condition of brick furnaces, grates and baffles. Examine brick
walls and cleaning doors for air leaks, either by shutting the damper and
observing the escaping smoke or by candle-flame test. Determine the
condition of heating surfaces with reference to exterior deposits of soot and
interior deposits of mud or scale.
See that the steam main is so arranged that condensed and entrained water
cannot flow back into the boiler.
If the object of the test is to determine the highest efficiency or capacity
obtainable, any physical defects, or defects of operation, tending to make the
result unfavorable should first be remedied; all foul parts being cleaned, and the
whole put in first-class condition. If, on the other hand, the object is to ascertain
the performance under existing conditions, no such preparation is either required
or desired.
(C) General Precautions against Leakage:
In steam tests make sure that there is no leakage through blow-offs, drips, etc.,
or any steam or water connections of the plant or apparatus undergoing test,
which [Pg 268] would in any way affect the results. All such connections should
be blanked off, or satisfactory assurance should be obtained that there is leakage
neither out nor in. This is a most important matter, and no assurance should be
considered satisfactory unless it is susceptible of absolute demonstration.
3. FUEL
Determine the character of fuel to be used.[62] For tests of maximum efficiency
or capacity of the boiler to compare with other boilers, the coal should be of
some kind which is commercially regarded as a standard for the locality where
the test is made.
In the Eastern States the standards thus regarded for semi-bituminous coals
are Pocahontas (Va. and W. Va.) and New River (W. Va.); for anthracite
coals those of the No. 1 buckwheat size, fresh-mined, containing not over
13 per cent ash by analysis; and for bituminous coals, Youghiogheny and
Pittsburgh coals. In some sections east of the Allegheny Mountains the
semi-bituminous Clearfield (Pa.) and Cumberland (Md.) are also
considered as standards. These coals when of good quality possess the
Page 369
essentials of excellence, adaptability to various kinds of furnaces, grates,
boilers, and methods of firing required, besides being widely distributed
and generally accessible in the Eastern market. There are no special grades
of coal mined in the Western States which are widely and generally
considered as standards for testing purposes; the best coal obtainable in any
particular locality being regarded as the standard of comparison.
A coal selected for maximum efficiency and capacity tests, should be the best of
its class, and especially free from slagging and unusual clinker-forming
impurities.
For guarantee and other tests with a specified coal containing not more than a
certain amount of ash and moisture, the coal selected should not be higher in ash
and in moisture than the stated amounts, because any increase is liable to reduce
the efficiency and capacity more than the equivalent proportion of such increase.
The size of the coal, especially where it is of the anthracite class, should be
determined by screening a suitable sample.
4. APPARATUS AND INSTRUMENTS[63]
The apparatus and instruments required for boiler tests are:
(A) Platform scales for weighing coal and ashes.
(B) Graduated scales attached to the water glasses.
(C) Tanks and platform scales for weighing water (or water meters
calibrated in place). Wherever practicable the feed water should be
weighed, especially for guarantee tests. The most satisfactory and reliable
apparatus for this purpose consists of one or more tanks each placed on
platform scales, these being elevated a sufficient distance above the floor to
empty into a receiving tank placed below, the latter being connected to the
feed pump. Where only one weighing tank is used the receiving tank
should be of larger size than the weighing tank, to afford sufficient reserve
supply to the pump while the upper tank is filling. If a single weighing tank
is used it should preferably be of such capacity as to require emptying not
oftener than every 5 minutes. If two or more are used the intervals between
successive emptyings should not be less than 3 minutes.
boilers, and methods of firing required, besides being widely distributed
and generally accessible in the Eastern market. There are no special grades
of coal mined in the Western States which are widely and generally
considered as standards for testing purposes; the best coal obtainable in any
particular locality being regarded as the standard of comparison.
A coal selected for maximum efficiency and capacity tests, should be the best of
its class, and especially free from slagging and unusual clinker-forming
impurities.
For guarantee and other tests with a specified coal containing not more than a
certain amount of ash and moisture, the coal selected should not be higher in ash
and in moisture than the stated amounts, because any increase is liable to reduce
the efficiency and capacity more than the equivalent proportion of such increase.
The size of the coal, especially where it is of the anthracite class, should be
determined by screening a suitable sample.
4. APPARATUS AND INSTRUMENTS[63]
The apparatus and instruments required for boiler tests are:
(A) Platform scales for weighing coal and ashes.
(B) Graduated scales attached to the water glasses.
(C) Tanks and platform scales for weighing water (or water meters
calibrated in place). Wherever practicable the feed water should be
weighed, especially for guarantee tests. The most satisfactory and reliable
apparatus for this purpose consists of one or more tanks each placed on
platform scales, these being elevated a sufficient distance above the floor to
empty into a receiving tank placed below, the latter being connected to the
feed pump. Where only one weighing tank is used the receiving tank
should be of larger size than the weighing tank, to afford sufficient reserve
supply to the pump while the upper tank is filling. If a single weighing tank
is used it should preferably be of such capacity as to require emptying not
oftener than every 5 minutes. If two or more are used the intervals between
successive emptyings should not be less than 3 minutes.
Page 370
(D) Pressure gauges, thermometers, and draft gauges.
(E) Calorimeters for determining the calorific value of fuel and the quality
of steam.
(F) Furnaces pyrometers.
(G) Gas analyzing apparatus.
5. OPERATING CONDITIONS [Pg 269]
Determine what the operating conditions and method of firing should be to
conform to the object in view, and see that they prevail throughout the trial, as
nearly as possible.
Where uniformity in the rate of evaporation is required, arrangement can be
usually made to dispose of the steam so that this result can be attained. In a
single boiler it may be accomplished by discharging steam through a waste
pipe and regulating the amount by means of a valve. In a battery of boilers,
in which only one is tested, the draft may be regulated on the remaining
boilers to meet the varying demands for steam, leaving the test boiler to
work under a steady rate of evaporation.
6. DURATION
The duration of tests to determine the efficiency of a hand-fired boiler, should be
10 hours of continuous running, or such time as may be required to burn a total
of 250 pounds of coal per square foot of grate.
In the case of a boiler using a mechanical stoker, the duration, where practicable,
should be at least 24 hours. If the stoker is of a type that permits the quantity and
condition of the fuel bed at beginning and end of the test to be accurately
estimated, the duration may be reduced to 10 hours, or such time as may be
required to burn the above noted total of 250 pounds per square foot.
In commercial tests where the service requires continuous operation night
and day, with frequent shifts of firemen, the duration of the test, whether
the boilers are hand fired or stoker fired, should be at least 24 hours.
Likewise in commercial tests, either of a single boiler or of a plant of
several boilers, which operate regularly a certain number of hours and
(E) Calorimeters for determining the calorific value of fuel and the quality
of steam.
(F) Furnaces pyrometers.
(G) Gas analyzing apparatus.
5. OPERATING CONDITIONS [Pg 269]
Determine what the operating conditions and method of firing should be to
conform to the object in view, and see that they prevail throughout the trial, as
nearly as possible.
Where uniformity in the rate of evaporation is required, arrangement can be
usually made to dispose of the steam so that this result can be attained. In a
single boiler it may be accomplished by discharging steam through a waste
pipe and regulating the amount by means of a valve. In a battery of boilers,
in which only one is tested, the draft may be regulated on the remaining
boilers to meet the varying demands for steam, leaving the test boiler to
work under a steady rate of evaporation.
6. DURATION
The duration of tests to determine the efficiency of a hand-fired boiler, should be
10 hours of continuous running, or such time as may be required to burn a total
of 250 pounds of coal per square foot of grate.
In the case of a boiler using a mechanical stoker, the duration, where practicable,
should be at least 24 hours. If the stoker is of a type that permits the quantity and
condition of the fuel bed at beginning and end of the test to be accurately
estimated, the duration may be reduced to 10 hours, or such time as may be
required to burn the above noted total of 250 pounds per square foot.
In commercial tests where the service requires continuous operation night
and day, with frequent shifts of firemen, the duration of the test, whether
the boilers are hand fired or stoker fired, should be at least 24 hours.
Likewise in commercial tests, either of a single boiler or of a plant of
several boilers, which operate regularly a certain number of hours and
Page 371
during the balance of the day the fires are banked, the duration should not
be less than 24 hours.
The duration of tests to determine the maximum evaporative capacity of a
boiler, without determining the efficiency, should not be less than 3 hours.
7. STARTING AND STOPPING
The conditions regarding the temperature of the furnace and boiler, the quantity
and quality of the live coal and ash on the grates, the water level, and the steam
pressure, should be as nearly as possible the same at the end as at the beginning
of the test.
To secure the desired equality of conditions with hand-fired boilers, the
following method should be employed:
The furnace being well heated by a preliminary run, burn the fire low, and
thoroughly clean it, leaving enough live coal spread evenly over the grate
(say 2 to 4 inches),[64] to serve as a foundation for the new fire. Note
quickly the thickness of the coal bed as nearly as it can be estimated or
measured; also the water level,[65] the steam pressure, and the time, and
record the latter as the starting time. Fresh coal should then be fired from
that weighed for the test, the ashpit throughly cleaned, and the regular work
of the test proceeded with. Before the end of the test the fire should again
be burned low and cleaned in such a manner as to leave the same amount of
live coal on the grate as at the start. When this condition is reached, observe
quickly the water level,[65] the steam pressure, and the time, and record the
latter as the stopping time. If the water level is not the same as at the
beginning a correction should be made by computation, rather than by
feeding additional water after the final readings are taken. Finally remove
the ashes and refuse from the ashpit. [Pg 270] In a plant containing several
boilers where it is not practicable to clean them simultaneously, the fires
should be cleaned one after the other as rapidly as may be, and each one
after cleaning charged with enough coal to maintain a thin fire in good
working condition. After the last fire is cleaned and in working condition,
burn all the fires low (say 4 to 6 inches), note quickly the thickness of each,
also the water levels, steam pressure, and time, which last is taken as the
starting time. Likewise when the time arrives for closing the test, the fires
should be quickly cleaned one by one, and when this work is completed
they should all be burned low the same as the start, and the various
be less than 24 hours.
The duration of tests to determine the maximum evaporative capacity of a
boiler, without determining the efficiency, should not be less than 3 hours.
7. STARTING AND STOPPING
The conditions regarding the temperature of the furnace and boiler, the quantity
and quality of the live coal and ash on the grates, the water level, and the steam
pressure, should be as nearly as possible the same at the end as at the beginning
of the test.
To secure the desired equality of conditions with hand-fired boilers, the
following method should be employed:
The furnace being well heated by a preliminary run, burn the fire low, and
thoroughly clean it, leaving enough live coal spread evenly over the grate
(say 2 to 4 inches),[64] to serve as a foundation for the new fire. Note
quickly the thickness of the coal bed as nearly as it can be estimated or
measured; also the water level,[65] the steam pressure, and the time, and
record the latter as the starting time. Fresh coal should then be fired from
that weighed for the test, the ashpit throughly cleaned, and the regular work
of the test proceeded with. Before the end of the test the fire should again
be burned low and cleaned in such a manner as to leave the same amount of
live coal on the grate as at the start. When this condition is reached, observe
quickly the water level,[65] the steam pressure, and the time, and record the
latter as the stopping time. If the water level is not the same as at the
beginning a correction should be made by computation, rather than by
feeding additional water after the final readings are taken. Finally remove
the ashes and refuse from the ashpit. [Pg 270] In a plant containing several
boilers where it is not practicable to clean them simultaneously, the fires
should be cleaned one after the other as rapidly as may be, and each one
after cleaning charged with enough coal to maintain a thin fire in good
working condition. After the last fire is cleaned and in working condition,
burn all the fires low (say 4 to 6 inches), note quickly the thickness of each,
also the water levels, steam pressure, and time, which last is taken as the
starting time. Likewise when the time arrives for closing the test, the fires
should be quickly cleaned one by one, and when this work is completed
they should all be burned low the same as the start, and the various
Page 372
observations made as noted. In the case of a large boiler having several
furnace doors requiring the fire to be cleaned in sections one after the other,
the above directions pertaining to starting and stopping in a plant of several
boilers may be followed.
To obtain the desired equality of conditions of the fire when a mechanical stoker
other than a chain grate is used, the procedure should be modified where
practicable as follows:
Regulate the coal feed so as to burn the fire to the low condition required
for cleaning. Shut off the coal-feeding mechanism and fill the hoppers level
full. Clean the ash or dump plate, note quickly the depth and condition of
the coal on the grate, the water level,[66] the steam pressure, and the time,
and record the latter as the starting time. Then start the coal-feeding
mechanism, clean the ashpit, and proceed with the regular work of the test.
When the time arrives for the close of the test, shut off the coal-feeding
mechanism, fill the hoppers and burn the fire to the same low point as at the
beginning. When this condition is reached, note the water level, the steam
pressure, and the time, and record the latter as the stopping time. Finally
clean the ashplate and haul the ashes.
In the case of chain grate stokers, the desired operating conditions should
be maintained for half an hour before starting a test and for a like period
before its close, the height of the throat plate and the speed of the grate
being the same during both of these periods.
8. RECORDS
A log of the data should be entered in notebooks or on blank sheets suitably
prepared in advance. This should be done in such manner that the test may be
divided into hourly periods, or if necessary, periods of less duration, and the
leading data obtained for any one or more periods as desired, thereby showing
the degree of uniformity obtained.
Half-hourly readings of the instruments are usually sufficient. If there are
sudden and wide fluctuations, the readings in such cases should be taken every
15 minutes, and in some instances oftener.
furnace doors requiring the fire to be cleaned in sections one after the other,
the above directions pertaining to starting and stopping in a plant of several
boilers may be followed.
To obtain the desired equality of conditions of the fire when a mechanical stoker
other than a chain grate is used, the procedure should be modified where
practicable as follows:
Regulate the coal feed so as to burn the fire to the low condition required
for cleaning. Shut off the coal-feeding mechanism and fill the hoppers level
full. Clean the ash or dump plate, note quickly the depth and condition of
the coal on the grate, the water level,[66] the steam pressure, and the time,
and record the latter as the starting time. Then start the coal-feeding
mechanism, clean the ashpit, and proceed with the regular work of the test.
When the time arrives for the close of the test, shut off the coal-feeding
mechanism, fill the hoppers and burn the fire to the same low point as at the
beginning. When this condition is reached, note the water level, the steam
pressure, and the time, and record the latter as the stopping time. Finally
clean the ashplate and haul the ashes.
In the case of chain grate stokers, the desired operating conditions should
be maintained for half an hour before starting a test and for a like period
before its close, the height of the throat plate and the speed of the grate
being the same during both of these periods.
8. RECORDS
A log of the data should be entered in notebooks or on blank sheets suitably
prepared in advance. This should be done in such manner that the test may be
divided into hourly periods, or if necessary, periods of less duration, and the
leading data obtained for any one or more periods as desired, thereby showing
the degree of uniformity obtained.
Half-hourly readings of the instruments are usually sufficient. If there are
sudden and wide fluctuations, the readings in such cases should be taken every
15 minutes, and in some instances oftener.
Page 373
The coal should be weighed and delivered to the firemen in portions
sufficient for one hour’s run, thereby ascertaining the degree of uniformity
of firing. An ample supply of coal should be maintained at all times, but the
quantity on the floor at the end of each hour should be as small as
practicable, so that the same may be readily estimated and deducted from
the total weight.
The records should be such as to ascertain also the consumption of feed
water each hour and thereby determine the degree of uniformity of
evaporation.
9. QUALITY OF STEAM[67]
If the boiler does not produce superheated steam the percentage of moisture in
the steam should be determined by the use of a throttling or separating
calorimeter. If the boiler has superheating surface, the temperature of the steam
should be determined by the use of a thermometer inserted in a thermometer
well.
[Pg 271]
For saturated steam construct a sampling pipe or nozzle made of one-half inch
iron pipe and insert it in the steam main at a point where the entrained moisture
is likely to be most thoroughly mixed. The inner end of the pipe, which should
extend nearly across to the opposite side of the main, should be closed and
interior portion perforated with not less than twenty one-eighth inch holes
equally distributed from end to end and preferably drilled in irregular or spiral
rows, with the first hole not less than half an inch from the wall of the pipe.
The sampling pipe should not be placed near a point where water may
pocket or where such water may effect the amount of moisture contained in
the sample. Where non-return valves are used, or there are horizontal
connections leading from the boiler to a vertical outlet, water may collect at
the lower end of the uptake pipe and be blown upward in a spray which
will not be carried away by the steam owing to a lack of velocity. A sample
taken from the lower part of this pipe will show a greater amount of
moisture than a true sample. With goose-neck connections a small amount
of water may collect on the bottom of the pipe near the upper end where the
inclination is such that the tendency to flow backward is ordinarily
counterbalanced by the flow of steam forward over its surface; but when
sufficient for one hour’s run, thereby ascertaining the degree of uniformity
of firing. An ample supply of coal should be maintained at all times, but the
quantity on the floor at the end of each hour should be as small as
practicable, so that the same may be readily estimated and deducted from
the total weight.
The records should be such as to ascertain also the consumption of feed
water each hour and thereby determine the degree of uniformity of
evaporation.
9. QUALITY OF STEAM[67]
If the boiler does not produce superheated steam the percentage of moisture in
the steam should be determined by the use of a throttling or separating
calorimeter. If the boiler has superheating surface, the temperature of the steam
should be determined by the use of a thermometer inserted in a thermometer
well.
[Pg 271]
For saturated steam construct a sampling pipe or nozzle made of one-half inch
iron pipe and insert it in the steam main at a point where the entrained moisture
is likely to be most thoroughly mixed. The inner end of the pipe, which should
extend nearly across to the opposite side of the main, should be closed and
interior portion perforated with not less than twenty one-eighth inch holes
equally distributed from end to end and preferably drilled in irregular or spiral
rows, with the first hole not less than half an inch from the wall of the pipe.
The sampling pipe should not be placed near a point where water may
pocket or where such water may effect the amount of moisture contained in
the sample. Where non-return valves are used, or there are horizontal
connections leading from the boiler to a vertical outlet, water may collect at
the lower end of the uptake pipe and be blown upward in a spray which
will not be carried away by the steam owing to a lack of velocity. A sample
taken from the lower part of this pipe will show a greater amount of
moisture than a true sample. With goose-neck connections a small amount
of water may collect on the bottom of the pipe near the upper end where the
inclination is such that the tendency to flow backward is ordinarily
counterbalanced by the flow of steam forward over its surface; but when
Page 374
the velocity momentarily decreases the water flows back to the lower end
of the goose-neck and increases the moisture at that point, making it an
undesirable location for sampling. In any case it must be borne in mind that
with low velocities the tendency is for drops of entrained water to settle to
the bottom of the pipe, and to be temporarily broken up into spray
whenever an abrupt bend or other disturbance is met.
If it is necessary to attach the sampling nozzle at a point near the end of a long
horizontal run, a drip pipe should be provided a short distance in front of the
nozzle, preferably at a pocket formed by some fitting and the water running
along the bottom of the main drawn off, weighed, and added to the moisture
shown by the calorimeter; or, better, a steam separator should be installed at the
point noted.
In testing a stationary boiler the sampling pipe should be located as near as
practicable to the boiler, and the same is true as regards the thermometer well
when the steam is superheated. In an engine or turbine test these locations
should be as near as practicable to throttle valve. In the test of a plant where it is
desired to get complete information, especially where the steam main is
unusually long, sampling nozzles or thermometer wells should be provided at
both points, so as to obtain data at either point as may be required.
10. SAMPLING AND DRYING COAL
During the progress of test the coal should be regularly sampled for the purpose
of analysis and determination of moisture.
Select a representative shovelful from each barrow-load as it is drawn from the
coal pile or other source of supply, and store the samples in a cool place in a
covered metal receptacle. When all the coal has thus been sampled, break up the
lumps, thoroughly mix the whole quantity, and finally reduce it by the process of
repeated quartering and crushing to a sample weighing about 5 pounds, the
largest pieces being about the size of a pea. From this sample two one-quart air-
tight glass fruit jars, or other air-tight vessels, are to be promptly filled and
preserved for subsequent determinations of moisture, calorific value, and
chemical composition. These operations should be conducted where the air is
cool and free from drafts.
When the sample lot of coal has been reduced by quartering to, say, 100 pounds,
a portion weighing, say, 15 to 20 pounds should be withdrawn for the purpose of
of the goose-neck and increases the moisture at that point, making it an
undesirable location for sampling. In any case it must be borne in mind that
with low velocities the tendency is for drops of entrained water to settle to
the bottom of the pipe, and to be temporarily broken up into spray
whenever an abrupt bend or other disturbance is met.
If it is necessary to attach the sampling nozzle at a point near the end of a long
horizontal run, a drip pipe should be provided a short distance in front of the
nozzle, preferably at a pocket formed by some fitting and the water running
along the bottom of the main drawn off, weighed, and added to the moisture
shown by the calorimeter; or, better, a steam separator should be installed at the
point noted.
In testing a stationary boiler the sampling pipe should be located as near as
practicable to the boiler, and the same is true as regards the thermometer well
when the steam is superheated. In an engine or turbine test these locations
should be as near as practicable to throttle valve. In the test of a plant where it is
desired to get complete information, especially where the steam main is
unusually long, sampling nozzles or thermometer wells should be provided at
both points, so as to obtain data at either point as may be required.
10. SAMPLING AND DRYING COAL
During the progress of test the coal should be regularly sampled for the purpose
of analysis and determination of moisture.
Select a representative shovelful from each barrow-load as it is drawn from the
coal pile or other source of supply, and store the samples in a cool place in a
covered metal receptacle. When all the coal has thus been sampled, break up the
lumps, thoroughly mix the whole quantity, and finally reduce it by the process of
repeated quartering and crushing to a sample weighing about 5 pounds, the
largest pieces being about the size of a pea. From this sample two one-quart air-
tight glass fruit jars, or other air-tight vessels, are to be promptly filled and
preserved for subsequent determinations of moisture, calorific value, and
chemical composition. These operations should be conducted where the air is
cool and free from drafts.
When the sample lot of coal has been reduced by quartering to, say, 100 pounds,
a portion weighing, say, 15 to 20 pounds should be withdrawn for the purpose of
Page 375
[Pg 272]
[Pg 273] immediate moisture determination. This is placed in a shallow iron pan
and dried on the hot iron boiler flue for at least 12 hours, being weighed before
and after drying on scales reading to quarter ounces.
3460 Horse-power Installation of Babcock & Wilcox Boilers at the Chicago,
Ill., Shops of the Chicago and Northwestern Ry. Co.
The moisture thus determined is approximately reliable for anthracite and semi-
bituminous coals, but not for coals containing much inherent moisture. For such
coals, and for all absolutely reliable determinations the method to be pursued is
as follows:
Take one of the samples contained in the glass jars, and subject it to a
thorough air drying, by spreading it in a thin layer and exposing it for
several hours to the atmosphere of a warm room, weighing it before and
after, thereby determining the quantity of surface moisture it contains.[68]
Then crush the whole of it by running it through an ordinary coffee mill or
other suitable crusher adjusted so as to produce somewhat coarse grains
(less than 1⁄16 inch), thoroughly mix the crushed sample, select from it a
portion of from 10 to 50 grams,[69] weigh it in a balance which will easily
[Pg 273] immediate moisture determination. This is placed in a shallow iron pan
and dried on the hot iron boiler flue for at least 12 hours, being weighed before
and after drying on scales reading to quarter ounces.
3460 Horse-power Installation of Babcock & Wilcox Boilers at the Chicago,
Ill., Shops of the Chicago and Northwestern Ry. Co.
The moisture thus determined is approximately reliable for anthracite and semi-
bituminous coals, but not for coals containing much inherent moisture. For such
coals, and for all absolutely reliable determinations the method to be pursued is
as follows:
Take one of the samples contained in the glass jars, and subject it to a
thorough air drying, by spreading it in a thin layer and exposing it for
several hours to the atmosphere of a warm room, weighing it before and
after, thereby determining the quantity of surface moisture it contains.[68]
Then crush the whole of it by running it through an ordinary coffee mill or
other suitable crusher adjusted so as to produce somewhat coarse grains
(less than 1⁄16 inch), thoroughly mix the crushed sample, select from it a
portion of from 10 to 50 grams,[69] weigh it in a balance which will easily
Page 376
show a variation as small as 1 part in 1000, and dry it for one hour in an air
or sand bath at a temperature between 240 and 280 degrees Fahrenheit.
Weigh it and record the loss, then heat and weigh again until the minimum
weight has been reached. The difference between the original and the
minimum weight is the moisture in the air-dried coal. The sum of the
moisture thus found and that of the surface moisture is the total moisture.
11. ASHES AND REFUSE
The ashes and refuse withdrawn from the furnace and ashpit during the progress
of the test and at its close should be weighed so far as possible in a dry state. If
wet the amount of moisture should be ascertained and allowed for, a sample
being taken and dried for this purpose. This sample may serve also for analysis
and the determination of unburned carbon and fusing temperature.
The method above described for sampling coal may also be followed for
obtaining a sample of the ashes and refuse.
12. CALORIFIC TESTS AND ANALYSES OF COAL
The quality of the fuel should be determined by calorific tests and analysis of the
coal sample above referred to.[70]
13. ANALYSES OF FLUE GASES
For approximate determinations of the composition of the flue gases, the Orsat
apparatus, or some modification thereof, should be employed. If momentary
samples are obtained the analyses should be made as frequently as possible, say,
every 15 to 30 minutes, depending on the skill of the operator, noting at the time
the sample is drawn the furnace and firing conditions. If the sample drawn is a
continuous one, the intervals may be made longer.
14. SMOKE OBSERVATIONS[71]
In tests of bituminous coals requiring a determination of the amount of smoke
produced, observations should be made regularly throughout the trial at intervals
of [Pg 274] 5 minutes (or if necessary every minute), noting at the same time the
furnace and firing conditions.
or sand bath at a temperature between 240 and 280 degrees Fahrenheit.
Weigh it and record the loss, then heat and weigh again until the minimum
weight has been reached. The difference between the original and the
minimum weight is the moisture in the air-dried coal. The sum of the
moisture thus found and that of the surface moisture is the total moisture.
11. ASHES AND REFUSE
The ashes and refuse withdrawn from the furnace and ashpit during the progress
of the test and at its close should be weighed so far as possible in a dry state. If
wet the amount of moisture should be ascertained and allowed for, a sample
being taken and dried for this purpose. This sample may serve also for analysis
and the determination of unburned carbon and fusing temperature.
The method above described for sampling coal may also be followed for
obtaining a sample of the ashes and refuse.
12. CALORIFIC TESTS AND ANALYSES OF COAL
The quality of the fuel should be determined by calorific tests and analysis of the
coal sample above referred to.[70]
13. ANALYSES OF FLUE GASES
For approximate determinations of the composition of the flue gases, the Orsat
apparatus, or some modification thereof, should be employed. If momentary
samples are obtained the analyses should be made as frequently as possible, say,
every 15 to 30 minutes, depending on the skill of the operator, noting at the time
the sample is drawn the furnace and firing conditions. If the sample drawn is a
continuous one, the intervals may be made longer.
14. SMOKE OBSERVATIONS[71]
In tests of bituminous coals requiring a determination of the amount of smoke
produced, observations should be made regularly throughout the trial at intervals
of [Pg 274] 5 minutes (or if necessary every minute), noting at the same time the
furnace and firing conditions.
Page 377
15. CALCULATION OF RESULTS
The methods to be followed in expressing and calculating those results which
are not self-evident are explained as follows:
(A) Efficiency. The “efficiency of boiler, furnace and grate” is the relation
between the heat absorbed per pound of coal fired, and the calorific value
of one pound of coal.
The “efficiency of boiler and furnace” is the relation between the heat
absorbed per pound of combustible burned, and the calorific value of one
pound of combustible. This expression of efficiency furnishes a means for
comparing one boiler and furnace with another, when the losses of
unburned coal due to grates, cleanings, etc., are eliminated.
The “combustible burned” is determined by subtracting from the weight of
coal supplied to the boiler, the moisture in the coal, the weight of ash and
unburned coal withdrawn from the furnace and ashpit, and the weight of
dust, soot, and refuse, if any, withdrawn from the tubes, flues, and
combustion chambers, including ash carried away in the gases, if any,
determined from the analysis of coal and ash. The “combustible” used for
determining the calorific value is the weight of coal less the moisture and
ash found by analysis.
The “heat absorbed” per pound of coal, or combustible, is calculated by
multiplying the equivalent evaporation from and at 212 degrees per pound
of coal or combustible by 970.4.
Other items in this section which have been treated elsewhere are:
(B) Corrections for moisture in steam.
(C) Correction for live steam used.
(D) Equivalent evaporation.
(E) Heat balance.
(F) Total heat of combustion of coal.
The methods to be followed in expressing and calculating those results which
are not self-evident are explained as follows:
(A) Efficiency. The “efficiency of boiler, furnace and grate” is the relation
between the heat absorbed per pound of coal fired, and the calorific value
of one pound of coal.
The “efficiency of boiler and furnace” is the relation between the heat
absorbed per pound of combustible burned, and the calorific value of one
pound of combustible. This expression of efficiency furnishes a means for
comparing one boiler and furnace with another, when the losses of
unburned coal due to grates, cleanings, etc., are eliminated.
The “combustible burned” is determined by subtracting from the weight of
coal supplied to the boiler, the moisture in the coal, the weight of ash and
unburned coal withdrawn from the furnace and ashpit, and the weight of
dust, soot, and refuse, if any, withdrawn from the tubes, flues, and
combustion chambers, including ash carried away in the gases, if any,
determined from the analysis of coal and ash. The “combustible” used for
determining the calorific value is the weight of coal less the moisture and
ash found by analysis.
The “heat absorbed” per pound of coal, or combustible, is calculated by
multiplying the equivalent evaporation from and at 212 degrees per pound
of coal or combustible by 970.4.
Other items in this section which have been treated elsewhere are:
(B) Corrections for moisture in steam.
(C) Correction for live steam used.
(D) Equivalent evaporation.
(E) Heat balance.
(F) Total heat of combustion of coal.
Page 378
(G) Air for combustion and the methods recommended for calculating these
results are in accordance with those described in different portions of this
book.
16. DATA AND RESULTS
The data and results should be reported in accordance with either the short form
or the complete form, adding lines for data not provided for, or omitting those
not required, as may conform to the object in view.
17. CHART
In trials having for an object the determination and exposition of the complete
boiler performance, the entire log of readings and data should be plotted on a
chart and represented graphically.
18. TESTS WITH OIL AND GAS FUELS
Tests of boilers using oil or gas for fuel should accord with the rules here given,
excepting as they are varied to conform to the particular characteristics of the
fuel. The duration in such cases may be reduced, and the “flying” method of
starting and stopping employed.
The table of data and results should contain items stating character of
furnace and burner, quality and composition of oil or gas, temperature of
oil, pressure of steam used for vaporizing and quantity of steam used for
both vaporizing and for heating.
TABLE DATA AND RESULTS OF EVAPORATIVE TEST
SHORT FORM, CODE OF 1912
1 Test of boiler located at
to determine conducted by
2 Kind of furnace
3 Grate surface square feet
4 Water-heating surface square feet
square feet
5 Superheating surface
[Pg 275]
6 Date
results are in accordance with those described in different portions of this
book.
16. DATA AND RESULTS
The data and results should be reported in accordance with either the short form
or the complete form, adding lines for data not provided for, or omitting those
not required, as may conform to the object in view.
17. CHART
In trials having for an object the determination and exposition of the complete
boiler performance, the entire log of readings and data should be plotted on a
chart and represented graphically.
18. TESTS WITH OIL AND GAS FUELS
Tests of boilers using oil or gas for fuel should accord with the rules here given,
excepting as they are varied to conform to the particular characteristics of the
fuel. The duration in such cases may be reduced, and the “flying” method of
starting and stopping employed.
The table of data and results should contain items stating character of
furnace and burner, quality and composition of oil or gas, temperature of
oil, pressure of steam used for vaporizing and quantity of steam used for
both vaporizing and for heating.
TABLE DATA AND RESULTS OF EVAPORATIVE TEST
SHORT FORM, CODE OF 1912
1 Test of boiler located at
to determine conducted by
2 Kind of furnace
3 Grate surface square feet
4 Water-heating surface square feet
square feet
5 Superheating surface
[Pg 275]
6 Date
Page 379
7 Duration hours
8 Kind and size of coal
AVERAGE PRESSURES, TEMPERATURES, ETC.
9 Steam pressure by gauge pounds
10 Temperature of feed water entering boiler degrees
11 Temperature of escaping gases leaving boiler degrees
12 Force of draft between damper and boiler inches
Percentage of moisture in steam, or number degrees of per cent or
13
superheating degrees
TOTAL QUANTITIES
14 Weight of coal as fired[72] pounds
15 Percentage of moisture in coal per cent
16 Total weight of dry coal consumed pounds
17 Total ash and refuse pounds
18 Percentage of ash and refuse in dry coal per cent
19 Total weight of water fed to the boiler[73] pounds
20 Total water evaporated, corrected for moisture in steam pounds
21 Total equivalent evaporation from and at 212 degrees pounds
HOURLY QUANTITIES AND RATES
22 Dry coal consumed per hour pounds
23 Dry coal per square feet of grate surface per hour pounds
24 Water evaporated per hour corrected for quality of steam pounds
25 Equivalent evaporation per hour from and at 212 degrees pounds
Equivalent evaporation per hour from and at 212 degrees per
26
square foot of water-
heating surface pounds
CAPACITY
Evaporation per hour from and at 212 degrees (same as Line
27 pounds
25)
boiler horse
28 Boiler horse power developed (Item 27 ÷ 34½)
power
Rated capacity, in evaporation from and at 212 degrees per
29 pounds
hour
boiler horse
30 Rated boiler horse power
power
31 Percentage of rated capacity developed per cent
ECONOMY RESULTS
8 Kind and size of coal
AVERAGE PRESSURES, TEMPERATURES, ETC.
9 Steam pressure by gauge pounds
10 Temperature of feed water entering boiler degrees
11 Temperature of escaping gases leaving boiler degrees
12 Force of draft between damper and boiler inches
Percentage of moisture in steam, or number degrees of per cent or
13
superheating degrees
TOTAL QUANTITIES
14 Weight of coal as fired[72] pounds
15 Percentage of moisture in coal per cent
16 Total weight of dry coal consumed pounds
17 Total ash and refuse pounds
18 Percentage of ash and refuse in dry coal per cent
19 Total weight of water fed to the boiler[73] pounds
20 Total water evaporated, corrected for moisture in steam pounds
21 Total equivalent evaporation from and at 212 degrees pounds
HOURLY QUANTITIES AND RATES
22 Dry coal consumed per hour pounds
23 Dry coal per square feet of grate surface per hour pounds
24 Water evaporated per hour corrected for quality of steam pounds
25 Equivalent evaporation per hour from and at 212 degrees pounds
Equivalent evaporation per hour from and at 212 degrees per
26
square foot of water-
heating surface pounds
CAPACITY
Evaporation per hour from and at 212 degrees (same as Line
27 pounds
25)
boiler horse
28 Boiler horse power developed (Item 27 ÷ 34½)
power
Rated capacity, in evaporation from and at 212 degrees per
29 pounds
hour
boiler horse
30 Rated boiler horse power
power
31 Percentage of rated capacity developed per cent
ECONOMY RESULTS
Page 380
32 Water fed per pound of coal fired (Item 19 ÷ Item 14) pounds
33 Water evaporated per pound of dry coal (Item 20 ÷ Item 16) pounds
Equivalent evaporation from and at 212 degrees per pound of
34
dry coal (Item 21 ÷
Item 16) pounds
Equivalent evaporation from and at 212 degrees per pound of
35
combustible [Item 21 ÷
(Item 16 - Item 17)] pounds
EFFICIENCY
36 Calorific value of one pound of dry coal B. t. u.
37 Calorific value of one pound of combustible B. t. u.
Item 34 × 970.4
Efficiency of boiler, furnace
38
and grate ( )
100 × –––––––––––––––––––––––––
Item 36
per cent
Item 35 × 970.4
( )
39 Efficiency of boiler and furnace 100 × –––––––––––––––––––––––––
Item 37
per cent
COST OF EVAPORATION
40 Cost of coal per ton ofpounds delivered in boiler room dollars
Cost of coal required for evaporating 1000 pounds of water dollars
41
from and at 212 degrees [Pg 276]
33 Water evaporated per pound of dry coal (Item 20 ÷ Item 16) pounds
Equivalent evaporation from and at 212 degrees per pound of
34
dry coal (Item 21 ÷
Item 16) pounds
Equivalent evaporation from and at 212 degrees per pound of
35
combustible [Item 21 ÷
(Item 16 - Item 17)] pounds
EFFICIENCY
36 Calorific value of one pound of dry coal B. t. u.
37 Calorific value of one pound of combustible B. t. u.
Item 34 × 970.4
Efficiency of boiler, furnace
38
and grate ( )
100 × –––––––––––––––––––––––––
Item 36
per cent
Item 35 × 970.4
( )
39 Efficiency of boiler and furnace 100 × –––––––––––––––––––––––––
Item 37
per cent
COST OF EVAPORATION
40 Cost of coal per ton ofpounds delivered in boiler room dollars
Cost of coal required for evaporating 1000 pounds of water dollars
41
from and at 212 degrees [Pg 276]
Page 381
Portion of 3600 Horse-power Installation of Babcock & Wilcox Boilers,
Equipped with Babcock & Wilcox Chain Grate Stokers at the Loomis
Street Plant of the Peoples Gas Light & Coke Co., Chicago, Ill. This
Company has Installed 7780 Horse Power of Babcock & Wilcox Boilers
FOOTNOTES
[54] To determine the portion of the fuel which is actually burned, the weight of ashes
should be computed from the total weight of coal burned and the coal and ash
analyses in order to allow for any ash that may be blown away with the flue gases. In
many cases the ash so computed is considerably higher than that found in the test.
[55] As distinguished from the efficiency of boiler, furnace and grate.
[56] To obtain the efficiency of the boiler as an absorber of the heat contained in the
hot gases, this should be the heat generated per pound of combustible corrected so
that any heat lost through incomplete combustion will not be charged to the boiler.
This, however, does not eliminate the furnace as the presence of excess air in the
gases lowers the efficiency and the ability to run without excess air depends on the
design and operation of the furnace. The efficiency based on the total heat value per
pound of combustible is, however, ordinarily taken as the efficiency of the boiler
notwithstanding the fact that it necessarily involves the furnace.
[57] See pages 280 and 281.
Equipped with Babcock & Wilcox Chain Grate Stokers at the Loomis
Street Plant of the Peoples Gas Light & Coke Co., Chicago, Ill. This
Company has Installed 7780 Horse Power of Babcock & Wilcox Boilers
FOOTNOTES
[54] To determine the portion of the fuel which is actually burned, the weight of ashes
should be computed from the total weight of coal burned and the coal and ash
analyses in order to allow for any ash that may be blown away with the flue gases. In
many cases the ash so computed is considerably higher than that found in the test.
[55] As distinguished from the efficiency of boiler, furnace and grate.
[56] To obtain the efficiency of the boiler as an absorber of the heat contained in the
hot gases, this should be the heat generated per pound of combustible corrected so
that any heat lost through incomplete combustion will not be charged to the boiler.
This, however, does not eliminate the furnace as the presence of excess air in the
gases lowers the efficiency and the ability to run without excess air depends on the
design and operation of the furnace. The efficiency based on the total heat value per
pound of combustible is, however, ordinarily taken as the efficiency of the boiler
notwithstanding the fact that it necessarily involves the furnace.
[57] See pages 280 and 281.
Page 382
[58] Where the horse power of marine boilers is stated, it generally refers to and is
synonymous with the horse power developed by the engines which they serve.
[59] In other countries, boilers are ordinarily rated not in horse power but by
specifying the quantity of water they are capable of evaporating from and at 212
degrees or under other conditions.
[60] See equivalent evaporation from and at 212 degrees, page 116.
[61] The recommendations are those made in the preliminary report of the Committee
on Power Tests and at the time of going to press have not been finally accepted by the
Society as a whole.
[62] This code relates primarily to tests made with coal.
[63] The necessary apparatus and instruments are described elsewhere. No definite
rules can be given for location of instruments. For suggestions on location, see A. S.
M. E. Code of 1912, Appendix 24. For calibration of instruments, see Code, Vol.
XXXIV, Trans., A. S. M. E., pages 1691-1702 and 1713-14.
[64] One to two inches for small anthracite coals.
[65] Do not blow down the water-glass column for at least one hour before these
readings are taken. An erroneous indication may otherwise be caused by a change of
temperature and density of the water within the column and connecting pipe.
[66] Do not blow down the water-glass column for at least one hour before these
readings are taken. An erroneous indication may otherwise be caused by a change of
temperature and density of the water within the column and connecting pipe.
[67] For calculations relating to quality of steam, see page 129.
[68] Where the coal is very moist, a portion of the moisture will cling to the walls of
the jar, and in such case the jar and fuel together should be dried out in determining
the total moisture.
[69] Say ½ ounce to 2 ounces.
[70] For methods of analysis, see page 176.
[71] For suggestions relative to Smoke Observations, see A. S. M. E. Code of 1912,
Appendix 16 and 17.
[72] The term “as fired” means actual condition including moisture, corrected for
estimated difference in weight of coal on the grate at beginning and end.
[73] Corrected for inequality of water level and steam pressure at beginning and end.
synonymous with the horse power developed by the engines which they serve.
[59] In other countries, boilers are ordinarily rated not in horse power but by
specifying the quantity of water they are capable of evaporating from and at 212
degrees or under other conditions.
[60] See equivalent evaporation from and at 212 degrees, page 116.
[61] The recommendations are those made in the preliminary report of the Committee
on Power Tests and at the time of going to press have not been finally accepted by the
Society as a whole.
[62] This code relates primarily to tests made with coal.
[63] The necessary apparatus and instruments are described elsewhere. No definite
rules can be given for location of instruments. For suggestions on location, see A. S.
M. E. Code of 1912, Appendix 24. For calibration of instruments, see Code, Vol.
XXXIV, Trans., A. S. M. E., pages 1691-1702 and 1713-14.
[64] One to two inches for small anthracite coals.
[65] Do not blow down the water-glass column for at least one hour before these
readings are taken. An erroneous indication may otherwise be caused by a change of
temperature and density of the water within the column and connecting pipe.
[66] Do not blow down the water-glass column for at least one hour before these
readings are taken. An erroneous indication may otherwise be caused by a change of
temperature and density of the water within the column and connecting pipe.
[67] For calculations relating to quality of steam, see page 129.
[68] Where the coal is very moist, a portion of the moisture will cling to the walls of
the jar, and in such case the jar and fuel together should be dried out in determining
the total moisture.
[69] Say ½ ounce to 2 ounces.
[70] For methods of analysis, see page 176.
[71] For suggestions relative to Smoke Observations, see A. S. M. E. Code of 1912,
Appendix 16 and 17.
[72] The term “as fired” means actual condition including moisture, corrected for
estimated difference in weight of coal on the grate at beginning and end.
[73] Corrected for inequality of water level and steam pressure at beginning and end.
Page 383
[Pg 277]
Page 384
THE SELECTION OF BOILERS WITH A CONSIDERATION OF
THE FACTORS DETERMINING SUCH SELECTION
The selection of steam boilers is a matter to which the most careful thought and attention may be well
given. Within the last twenty years, radical changes have taken place in the methods and appliances for the
generation and distribution of power. These changes have been made largely in the prime movers, both as
to type and size, and are best illustrated by the changes in central station power-plant practice. It is hardly
within the scope of this work to treat of power-plant design and the discussion will be limited to a
consideration of the boiler end of the power plant.
As stated, the changes have been largely in prime movers, the steam generating equipment having been
considered more or less of a standard piece of apparatus whose sole function is the transfer of the heat
liberated from the fuel by combustion to the steam stored or circulated in such apparatus. When the fact is
considered that the cost of steam generation is roughly from 65 to 80 per cent of the total cost of power
production, it may be readily understood that the most fruitful field for improvement exists in the boiler
end of the power plant. The efficiency of the plant as a whole will vary with the load it carries and it is in
the boiler room where such variation is largest and most subject to control.
The improvements to be secured in the boiler room results are not simply a matter of dictation of
operating methods. The securing of perfect combustion, with the accompanying efficiency of heat transfer,
while comparatively simple in theory, is difficult to obtain in practical operation. This fact is perhaps best
exemplified by the difference between test results and those obtained in daily operation even under the
most careful supervision. This difference makes it necessary to establish a standard by which operating
results may be judged, a standard not necessarily that which might be possible under test conditions but
one which experiment shows can be secured under the very best operating conditions.
The study of the theory of combustion, draft, etc., as already given, will indicate that the question of
efficiency is largely a matter of proper relation between fuel, furnace and generator. While the possibility
of a substantial saving through added efficiency cannot be overlooked, the boiler design of the future
must, even more than in the past, be considered particularly from the aspect of reliability and simplicity. A
flexibility of operation is necessary as a guarantee of continuity of service.
In view of the above, before the question of the selection of boilers can be taken up intelligently, it is
necessary to consider the subjects of boiler efficiency and boiler capacity, together with their relation to
each other.
The criterion by which the efficiency of a boiler plant is to be judged is the cost of the production of a
definite amount of steam. Considered in this sense, there must be included in the efficiency of a boiler
plant the simplicity of operation, flexibility and reliability of the boiler used. The items of repair and
upkeep cost are often high because of the nature of the service. The governing factor in these items is
unquestionably the type of boiler selected.
The features entering into the plant efficiency are so numerous that it is impossible to make a statement as
to a means of securing the highest efficiency which [Pg 278] will apply to all cases. Such efficiency is to be
secured by the proper relation of fuel, furnace and boiler heating surface, actual operating conditions,
which allow the approaching of the potential efficiencies made possible by the refinement of design, and a
systematic supervision of the operation assisted by a detailed record of performances and conditions. The
question of supervision will be taken up later in the chapter on “Operation and Care of Boilers”.
THE FACTORS DETERMINING SUCH SELECTION
The selection of steam boilers is a matter to which the most careful thought and attention may be well
given. Within the last twenty years, radical changes have taken place in the methods and appliances for the
generation and distribution of power. These changes have been made largely in the prime movers, both as
to type and size, and are best illustrated by the changes in central station power-plant practice. It is hardly
within the scope of this work to treat of power-plant design and the discussion will be limited to a
consideration of the boiler end of the power plant.
As stated, the changes have been largely in prime movers, the steam generating equipment having been
considered more or less of a standard piece of apparatus whose sole function is the transfer of the heat
liberated from the fuel by combustion to the steam stored or circulated in such apparatus. When the fact is
considered that the cost of steam generation is roughly from 65 to 80 per cent of the total cost of power
production, it may be readily understood that the most fruitful field for improvement exists in the boiler
end of the power plant. The efficiency of the plant as a whole will vary with the load it carries and it is in
the boiler room where such variation is largest and most subject to control.
The improvements to be secured in the boiler room results are not simply a matter of dictation of
operating methods. The securing of perfect combustion, with the accompanying efficiency of heat transfer,
while comparatively simple in theory, is difficult to obtain in practical operation. This fact is perhaps best
exemplified by the difference between test results and those obtained in daily operation even under the
most careful supervision. This difference makes it necessary to establish a standard by which operating
results may be judged, a standard not necessarily that which might be possible under test conditions but
one which experiment shows can be secured under the very best operating conditions.
The study of the theory of combustion, draft, etc., as already given, will indicate that the question of
efficiency is largely a matter of proper relation between fuel, furnace and generator. While the possibility
of a substantial saving through added efficiency cannot be overlooked, the boiler design of the future
must, even more than in the past, be considered particularly from the aspect of reliability and simplicity. A
flexibility of operation is necessary as a guarantee of continuity of service.
In view of the above, before the question of the selection of boilers can be taken up intelligently, it is
necessary to consider the subjects of boiler efficiency and boiler capacity, together with their relation to
each other.
The criterion by which the efficiency of a boiler plant is to be judged is the cost of the production of a
definite amount of steam. Considered in this sense, there must be included in the efficiency of a boiler
plant the simplicity of operation, flexibility and reliability of the boiler used. The items of repair and
upkeep cost are often high because of the nature of the service. The governing factor in these items is
unquestionably the type of boiler selected.
The features entering into the plant efficiency are so numerous that it is impossible to make a statement as
to a means of securing the highest efficiency which [Pg 278] will apply to all cases. Such efficiency is to be
secured by the proper relation of fuel, furnace and boiler heating surface, actual operating conditions,
which allow the approaching of the potential efficiencies made possible by the refinement of design, and a
systematic supervision of the operation assisted by a detailed record of performances and conditions. The
question of supervision will be taken up later in the chapter on “Operation and Care of Boilers”.
Page 385
The efficiencies that may be expected from the combination of well-designed boilers and furnaces are
indicated in Table 59 in which are given a number of tests with various fuels and under widely different
operating conditions.
It is to be appreciated that the results obtained as given in this table are practically all under test
conditions. The nearness with which practical operating conditions can approach these figures will depend
upon the character of the supervision of the boiler room and the intelligence of the operating crew. The
size of the plant will ordinarily govern the expense warranted in securing the right sort of supervision.
The bearing that the type of boiler has on the efficiency to be expected can only be realized from a study
of the foregoing chapters.
Capacity—Capacity, as already defined, is the ability of a definite amount of boiler-heating surface to
generate steam. Boilers are ordinarily purchased under a manufacturer’s specification, which rates a boiler
at a nominal rated horse power, usually based on 10 square feet of heating surface per horse power. Such a
builders’ rating is absolutely arbitrary and implies nothing as to the limiting amount of water that this
amount of heating surface will evaporate. It does not imply that the evaporation of 34.5 pounds of water
from and at 212 degrees with 10 square feet of heating surface is the limit of the capacity of the boiler.
Further, from a statement that a boiler is of a certain horse power on the manufacturer’s basis, it is not to
be understood that the boiler is in any state of strain when developing more than its rated capacity.
Broadly stated, the evaporative capacity of a certain amount of heating surface in a well-designed boiler,
that is, the boiler horse power it is capable of producing, is limited only by the amount of fuel that can be
burned under the boiler. While such a statement would imply that the question of capacity to be secured
was simply one of making an arrangement by which sufficient fuel could be burned under a definite
amount of heating surface to generate the required amount of steam, there are limiting features that must
be weighed against the advantages of high capacity developed from small heating surfaces. Briefly stated,
these factors are as follows:
1st. Efficiency. As the capacity increases, there will in general be a decrease in efficiency, this loss above a
certain point making it inadvisable to try to secure more than a definite horse power from a given boiler.
This loss of efficiency with increased capacity is treated below in detail, in considering the relation of
efficiency to capacity.
2nd. Grate Ratio Possible or Practicable. All fuels have a maximum rate of combustion, beyond which
satisfactory results cannot be obtained, regardless of draft available or which may be secured by
mechanical means. Such being the case, it is evident that with this maximum combustion rate secured, the
only method of obtaining added capacity will be through the addition of grate surface. There is obviously
a point beyond which the grate surface for a given boiler cannot be increased. This is due to the
impracticability of handling grates above a certain maximum size, to the enormous loss in draft pressure
through a boiler resulting from an attempt to force an [Pg 279] abnormal quantity of gas through the heating
surface and to innumerable details of design and maintenance that would make such an arrangement
wholly unfeasible.
3rd. Feed Water. The difficulties that may arise through the use of poor feed water or that are liable to
happen through the use of practically any feed water have already been pointed out. This question of feed
is frequently the limiting factor in the capacity obtainable, for with an increase in such capacity comes an
added concentration of such ingredients in the feed water as will cause priming, foaming or rapid scale
formation. Certain waters which will give no trouble that cannot be readily overcome with the boiler run
at ordinary ratings will cause difficulties at higher ratings entirely out of proportion to any advantage
secured by an increase in the power that a definite amount of heating surface may be made to produce.
indicated in Table 59 in which are given a number of tests with various fuels and under widely different
operating conditions.
It is to be appreciated that the results obtained as given in this table are practically all under test
conditions. The nearness with which practical operating conditions can approach these figures will depend
upon the character of the supervision of the boiler room and the intelligence of the operating crew. The
size of the plant will ordinarily govern the expense warranted in securing the right sort of supervision.
The bearing that the type of boiler has on the efficiency to be expected can only be realized from a study
of the foregoing chapters.
Capacity—Capacity, as already defined, is the ability of a definite amount of boiler-heating surface to
generate steam. Boilers are ordinarily purchased under a manufacturer’s specification, which rates a boiler
at a nominal rated horse power, usually based on 10 square feet of heating surface per horse power. Such a
builders’ rating is absolutely arbitrary and implies nothing as to the limiting amount of water that this
amount of heating surface will evaporate. It does not imply that the evaporation of 34.5 pounds of water
from and at 212 degrees with 10 square feet of heating surface is the limit of the capacity of the boiler.
Further, from a statement that a boiler is of a certain horse power on the manufacturer’s basis, it is not to
be understood that the boiler is in any state of strain when developing more than its rated capacity.
Broadly stated, the evaporative capacity of a certain amount of heating surface in a well-designed boiler,
that is, the boiler horse power it is capable of producing, is limited only by the amount of fuel that can be
burned under the boiler. While such a statement would imply that the question of capacity to be secured
was simply one of making an arrangement by which sufficient fuel could be burned under a definite
amount of heating surface to generate the required amount of steam, there are limiting features that must
be weighed against the advantages of high capacity developed from small heating surfaces. Briefly stated,
these factors are as follows:
1st. Efficiency. As the capacity increases, there will in general be a decrease in efficiency, this loss above a
certain point making it inadvisable to try to secure more than a definite horse power from a given boiler.
This loss of efficiency with increased capacity is treated below in detail, in considering the relation of
efficiency to capacity.
2nd. Grate Ratio Possible or Practicable. All fuels have a maximum rate of combustion, beyond which
satisfactory results cannot be obtained, regardless of draft available or which may be secured by
mechanical means. Such being the case, it is evident that with this maximum combustion rate secured, the
only method of obtaining added capacity will be through the addition of grate surface. There is obviously
a point beyond which the grate surface for a given boiler cannot be increased. This is due to the
impracticability of handling grates above a certain maximum size, to the enormous loss in draft pressure
through a boiler resulting from an attempt to force an [Pg 279] abnormal quantity of gas through the heating
surface and to innumerable details of design and maintenance that would make such an arrangement
wholly unfeasible.
3rd. Feed Water. The difficulties that may arise through the use of poor feed water or that are liable to
happen through the use of practically any feed water have already been pointed out. This question of feed
is frequently the limiting factor in the capacity obtainable, for with an increase in such capacity comes an
added concentration of such ingredients in the feed water as will cause priming, foaming or rapid scale
formation. Certain waters which will give no trouble that cannot be readily overcome with the boiler run
at ordinary ratings will cause difficulties at higher ratings entirely out of proportion to any advantage
secured by an increase in the power that a definite amount of heating surface may be made to produce.
Page 386
Where capacity in the sense of overload is desired, the type of boiler selected will play a large part in the
successful operation through such periods. A boiler must be selected with which there is possible a furnace
arrangement that will give flexibility without undue loss in efficiency over the range of capacity desired.
The heating surface must be so arranged that it will be possible to install in a practical manner, sufficient
grate surface at or below the maximum combustion rate to develop the amount of power required. The
design of boiler must be such that there will be no priming or foaming at high overloads and that any
added scale formation due to such overloads may be easily removed. Certain boilers which deliver
commercially dry steam when operated at about their normal rated capacity will prime badly when run at
overloads and this action may take place with a water that should be easily handled by a properly designed
boiler at any reasonable load. Such action is ordinarily produced by the lack of a well defined, positive
circulation.
Relation of Efficiency and Capacity—The statement has been made that in general the efficiency of a
boiler will decrease as the capacity is increased. Considering the boiler alone, apart from the furnace, this
statement may be readily explained.
Presupposing a constant furnace temperature, regardless of the capacity at which a given boiler is run; to
assure equal efficiencies at low and high ratings, the exit temperature in the two instances would
necessarily be the same. For this temperature at the high rating, to be identical with that at the low rating,
the rate of heat transfer from the gases to the heating surfaces would have to vary directly as the weight or
volume of such gases. Experiment has shown, however, that this is not true but that this rate of transfer
varies as some power of the volume of gas less than one. As the heat transfer does not, therefore, increase
proportionately with the volume of gases, the exit temperature for a given furnace temperature will be
increased as the volume of gases increases. As this is the measure of the efficiency of the heating surface,
the boiler efficiency will, therefore, decrease as the volume of gases increases or the capacity at which the
boiler is operated increases.
Further, a certain portion of the heat absorbed by the heating surface is through direct radiation from the
fire. Again, presupposing a constant furnace temperature; the heat absorbed through radiation is solely a
function of the amount of surface exposed to such radiation. Hence, for the conditions assumed, the
amount of heat absorbed by radiation at the higher ratings will be the same as at the lower ratings but in
proportion to the total absorption will be less. As the added volume of gas does not increase the rate of
heat transfer, there are therefore two factors acting toward the decrease in the efficiency of a boiler with an
increase in the capacity.
[Pg 280]
TABLE 59—Part 1
TESTS OF BABCOCK & WILCOX BOILERS WITH VARIOUS FUELS
Rated Steam Temperature Degrees Draft
Grate Duration
Number Name and Horse Pressure Feed of Factor At
Kind of Kind of Surface of In
of Location of Power by Water Superheat of Boiler
Coal Furnace Square Test Furnace
Test Plant of Gauge Degrees Degrees Evaporation Damper
Feet Hours Inches
Boiler Pounds Fahrenheit Fahrenheit Inches
Susquehanna
No. 1
Coal Co., Hand
1 Anthracite 300 84 8 68 53.9 1.1965 +.41 .21
Shenandoah, Fired
Buckwheat
Pa.
Balbach No. 2
Smelting & Buckwheat Wilkenson +.65
2 218 51.6 7 136.3 203 150 1.1480 .56
Refining Co., and Bird’s- Stoker .47
Newark, N. J. eye
H. R. No. 2
Hand
3 Worthington, Anthracite 300 67.6 8 139 139.6 139 1.1984 .70 .96
Fired
Harrison N. J. Buckwheat
successful operation through such periods. A boiler must be selected with which there is possible a furnace
arrangement that will give flexibility without undue loss in efficiency over the range of capacity desired.
The heating surface must be so arranged that it will be possible to install in a practical manner, sufficient
grate surface at or below the maximum combustion rate to develop the amount of power required. The
design of boiler must be such that there will be no priming or foaming at high overloads and that any
added scale formation due to such overloads may be easily removed. Certain boilers which deliver
commercially dry steam when operated at about their normal rated capacity will prime badly when run at
overloads and this action may take place with a water that should be easily handled by a properly designed
boiler at any reasonable load. Such action is ordinarily produced by the lack of a well defined, positive
circulation.
Relation of Efficiency and Capacity—The statement has been made that in general the efficiency of a
boiler will decrease as the capacity is increased. Considering the boiler alone, apart from the furnace, this
statement may be readily explained.
Presupposing a constant furnace temperature, regardless of the capacity at which a given boiler is run; to
assure equal efficiencies at low and high ratings, the exit temperature in the two instances would
necessarily be the same. For this temperature at the high rating, to be identical with that at the low rating,
the rate of heat transfer from the gases to the heating surfaces would have to vary directly as the weight or
volume of such gases. Experiment has shown, however, that this is not true but that this rate of transfer
varies as some power of the volume of gas less than one. As the heat transfer does not, therefore, increase
proportionately with the volume of gases, the exit temperature for a given furnace temperature will be
increased as the volume of gases increases. As this is the measure of the efficiency of the heating surface,
the boiler efficiency will, therefore, decrease as the volume of gases increases or the capacity at which the
boiler is operated increases.
Further, a certain portion of the heat absorbed by the heating surface is through direct radiation from the
fire. Again, presupposing a constant furnace temperature; the heat absorbed through radiation is solely a
function of the amount of surface exposed to such radiation. Hence, for the conditions assumed, the
amount of heat absorbed by radiation at the higher ratings will be the same as at the lower ratings but in
proportion to the total absorption will be less. As the added volume of gas does not increase the rate of
heat transfer, there are therefore two factors acting toward the decrease in the efficiency of a boiler with an
increase in the capacity.
[Pg 280]
TABLE 59—Part 1
TESTS OF BABCOCK & WILCOX BOILERS WITH VARIOUS FUELS
Rated Steam Temperature Degrees Draft
Grate Duration
Number Name and Horse Pressure Feed of Factor At
Kind of Kind of Surface of In
of Location of Power by Water Superheat of Boiler
Coal Furnace Square Test Furnace
Test Plant of Gauge Degrees Degrees Evaporation Damper
Feet Hours Inches
Boiler Pounds Fahrenheit Fahrenheit Inches
Susquehanna
No. 1
Coal Co., Hand
1 Anthracite 300 84 8 68 53.9 1.1965 +.41 .21
Shenandoah, Fired
Buckwheat
Pa.
Balbach No. 2
Smelting & Buckwheat Wilkenson +.65
2 218 51.6 7 136.3 203 150 1.1480 .56
Refining Co., and Bird’s- Stoker .47
Newark, N. J. eye
H. R. No. 2
Hand
3 Worthington, Anthracite 300 67.6 8 139 139.6 139 1.1984 .70 .96
Fired
Harrison N. J. Buckwheat
Page 387
Raymond
Anthracite Hand
4 Street Jail, 155 40 8 110.2 137 1.1185 .33 .43
Pea Fired
Brooklyn, N. Y.
R. H. Macy & No. 3
Hand
5 Co., New York, Anthracite 293 59.5 10 133.2 75.2 1.1849 .19 .40
Fired
N. Y. Buckwheat
National
Bureau of
Anthracite Hand
6 Standards, 119 26.5 18 132.1 70.5 1.1897 .33
Egg Fired
Washington,
D.C.
Fred. Loeser & No. 1
Hand +.51
7 Co., Brooklyn, Anthracite 300 48.9 7 101 121.3 1.1333 .30
Fired -.20
N. Y. Buckwheat
New York No. 2
Hand
8 Edison Co., Anthracite 374 59.5 6 191.8 88.3 1.1771 .50
Fired
New York City Buckwheat
Sewage
Hocking
Pumping Hand
9 Valley 150 27 24 156.3 58 1.2051 .10 .24
Station, Fired
Lump, O.
Cleveland, O.
Scioto River
Hocking Hand
10 Pumping Sta., 300 24 145 75 1.1866 .26 .46
Valley, O. Fired
Cleveland, O.
Consolidated
Gas & Electric Somerset, Hand
11 640 118 8 170 186.1 66.7 1.1162 .34 .42
Co., Baltimore, Pa. Fired
Md.
Consolidated
Gas & Electric Somerset, Hand
12 640 118 7.92 173 180.2 75.2 1.1276 .44 .58
Co., Baltimore, Pa. Fired
Md.
Merrimac Mfg.
Georges Hand
13 Co., Lowell, 321 52 24 75 53.3 1.1987 .25 .35
Creek, Md. Fired
Mass.
Great West’n Lafayette, Hand
14 Sugar Co., Ft. Col., Mine Fired 351 59.5 8 105 35.8 1.2219 .17 .38
Collins, Col. Run Extension
Baltimore
Sewage Hand
15 New River 266 59.5 24 170.1 133 1.1293 .12 .43
Pumping Fired
Station
Tennessee State
Brushy
Prison, Hand
16 Mountain, 300 51.3 10 105 75.1 1.1814 .21 .42
Nashville, Fired
Tenn.
Tenn.
Pine Bluff
Arkansas Hand
17 Corporation, 298 59.5 8 149.2 71 1.1910 .35 .59
Slack Fired
Pine Bluff, Ark.
Pub. Serv.
Valley, Pa., Roney
18 Corporation of 520 103.2 10 133.2 65.3 65.9 1.2346 .05 .49
Mine Run Stoker
N. J., Hoboken
Pub. Serv.
Valley, Pa., Roney
19 Corporation of 520 103.2 9 139 64 80.2 1.2358 .18 .57
Mine Run Stoker
N. J., Hoboken
Pittsburgh
Frick Building, American
20 Nut and 300 53 9 125 76.6 1.1826 +1.64 .64
Pittsburgh, Pa. Stoker
Slack
New York
Loyal Taylor
21 Edison Co., 604 75 8 198.5 165.1 104 1.1662 +3.05 .60
Hanna, Pa. Stoker
New York City
City of
Hocking Detroit
22 Columbus, O., 300 9 140 67 180 1.2942 .22 .35
Valley, O. Stoker
Dept. Lighting
Edison Elec.
Murphy
23 Illum. Co., New River 508 90 16.25 199 48.4 136.5 1.2996 .23 1.27
Stoker
Boston, Mass.
Anthracite Hand
4 Street Jail, 155 40 8 110.2 137 1.1185 .33 .43
Pea Fired
Brooklyn, N. Y.
R. H. Macy & No. 3
Hand
5 Co., New York, Anthracite 293 59.5 10 133.2 75.2 1.1849 .19 .40
Fired
N. Y. Buckwheat
National
Bureau of
Anthracite Hand
6 Standards, 119 26.5 18 132.1 70.5 1.1897 .33
Egg Fired
Washington,
D.C.
Fred. Loeser & No. 1
Hand +.51
7 Co., Brooklyn, Anthracite 300 48.9 7 101 121.3 1.1333 .30
Fired -.20
N. Y. Buckwheat
New York No. 2
Hand
8 Edison Co., Anthracite 374 59.5 6 191.8 88.3 1.1771 .50
Fired
New York City Buckwheat
Sewage
Hocking
Pumping Hand
9 Valley 150 27 24 156.3 58 1.2051 .10 .24
Station, Fired
Lump, O.
Cleveland, O.
Scioto River
Hocking Hand
10 Pumping Sta., 300 24 145 75 1.1866 .26 .46
Valley, O. Fired
Cleveland, O.
Consolidated
Gas & Electric Somerset, Hand
11 640 118 8 170 186.1 66.7 1.1162 .34 .42
Co., Baltimore, Pa. Fired
Md.
Consolidated
Gas & Electric Somerset, Hand
12 640 118 7.92 173 180.2 75.2 1.1276 .44 .58
Co., Baltimore, Pa. Fired
Md.
Merrimac Mfg.
Georges Hand
13 Co., Lowell, 321 52 24 75 53.3 1.1987 .25 .35
Creek, Md. Fired
Mass.
Great West’n Lafayette, Hand
14 Sugar Co., Ft. Col., Mine Fired 351 59.5 8 105 35.8 1.2219 .17 .38
Collins, Col. Run Extension
Baltimore
Sewage Hand
15 New River 266 59.5 24 170.1 133 1.1293 .12 .43
Pumping Fired
Station
Tennessee State
Brushy
Prison, Hand
16 Mountain, 300 51.3 10 105 75.1 1.1814 .21 .42
Nashville, Fired
Tenn.
Tenn.
Pine Bluff
Arkansas Hand
17 Corporation, 298 59.5 8 149.2 71 1.1910 .35 .59
Slack Fired
Pine Bluff, Ark.
Pub. Serv.
Valley, Pa., Roney
18 Corporation of 520 103.2 10 133.2 65.3 65.9 1.2346 .05 .49
Mine Run Stoker
N. J., Hoboken
Pub. Serv.
Valley, Pa., Roney
19 Corporation of 520 103.2 9 139 64 80.2 1.2358 .18 .57
Mine Run Stoker
N. J., Hoboken
Pittsburgh
Frick Building, American
20 Nut and 300 53 9 125 76.6 1.1826 +1.64 .64
Pittsburgh, Pa. Stoker
Slack
New York
Loyal Taylor
21 Edison Co., 604 75 8 198.5 165.1 104 1.1662 +3.05 .60
Hanna, Pa. Stoker
New York City
City of
Hocking Detroit
22 Columbus, O., 300 9 140 67 180 1.2942 .22 .35
Valley, O. Stoker
Dept. Lighting
Edison Elec.
Murphy
23 Illum. Co., New River 508 90 16.25 199 48.4 136.5 1.2996 .23 1.27
Stoker
Boston, Mass.
Page 388
Colorado
Pike View, Green
Springs &
24 Col., Mine Chain 400 103 8 129 56 1.2002 .23 .30
Interurban Ry.,
Run Grate
Col.
Pub. Serv. B.&W.
Lancashire, +.52
25 Corporation of Chain 600 132 8 200 57.2 280.4 1.3909 .52
Pa. +.19
N. J., Marion Grate
Pub. Serv. B.&W.
Lancashire, +.15
26 Corporation of Chain 600 132 8 199 60.7 171.0 1.3191 .52
Pa. .04
N. J., Marion Grate
Erie County B.&W.
Mercer
27 Electric Co., Chain 508 90 8 120 69.9 1.1888 .31 .58
County, Pa.
Erie, Pa. Grate
Union Elec. Lt. B.&W.
Mascouth,
28 & Pr. Co., St. Chain 508 103.5 8 180 46 113 1.2871 .62 1.24
Ill.
Louis, Mo. Grate
Union Elec. Lt. B.&W.
St. Clair
29 & Pr. Co., St. Chain 508 103.5 8 183 53.1 104 1.2725 .60 1.26
County, Ill.
Louis, Mo. Grate
Commonwealth Carterville, B.&W.
30 Edison Co., Ill., Chain 508 90 7 184 127.1 180 1.2393 .68 1.15
Chicago, Ill. Screenings Grate
[Pg 281]
TABLE 59—Part 2
TESTS OF BABCOCK & WILCOX BOILERS WITH VARIOUS FUELS
Coal Water
Equivalent
Dry
Evaporation
Coal
@ >=212°
Temperature Total Per
Equivalent per
of Weight Ash Square Actual
Number Total Evaporation Square
Flue of Moisture and Total Foot Evaporation
of Dry @ >=212° Foot
Gases Coal Per Refuse Combustible of per
Test Coal per of
degrees as Cent Per Pounds Grate Hour
Pounds Hour Heating
Fahrenheit Fired Cent Surface Pounds
Pounds Surface
Pounds per
per
Hour
Hour
Pounds
Pounds
1 11670 4.45 11151 26.05 8248 16.6 10268 12286 4.10
2 487 8800 7.62 8129 29.82 5705 19.71 8246 9466 4.34
3 559 10799 6.42 10106 20.02 8081 21.77 9145 10959 3.65
4 427 5088 4.00 4884 19.35 3939 15.26 5006 5599 3.61
5 414 9440 2.14 9238 11.19 8204 15.52 7434 8809 3.06
6 410 8555 3.62 8245 15.73 6948 17.28 2903 3454 2.91
7 480 7130 7.38 6604 18.35 5392 19.29 7464 8459 2.82
8 449 7500 2.70 7298 27.94 5259 14.73 9164 10787 2.88
9 410 15087 7.50 13956 11.30 12379 21.5 4374 5271 3.51
10 503 29528 7.72 27248 24.7 8688 10309 3.44
11 487 20400 2.84 19821 7.83 18269 21.00 24036 26829 4.19
12 494 21332 2.29 20843 8.23 19127 22.31 25313 28544 4.46
13 516 24584 4.29 23529 7.63 21883 18.85 9168 10990 3.42
14 523 15540 18.64 12643 28.59 11202 13689 3.91
15 474 18330 2.03 17958 16.36 16096 12.57 7565 8543 3.21
16 536 12243 2.14 11981 23.40 9512 11237 3.74
17 534 10500 3.04 10181 21.40 9257 11025 3.70
18 458 18600 3.40 17968 18.38 14665 17.41 15887 19614 3.77
19 609 23400 2.56 22801 16.89 18951 24.55 21320 26347 5.06
20 518 10500 1.83 10308 12.22 9048 21.56 9976 11978 3.93
21 536 25296 2.20 24736 41.0 28451 33066 5.47
22 511 14263 8.63 13032 10467 13526 4.51
23 560 39670 4.22 37996 4.32 36355 25.98 20700 26902 5.30
Pike View, Green
Springs &
24 Col., Mine Chain 400 103 8 129 56 1.2002 .23 .30
Interurban Ry.,
Run Grate
Col.
Pub. Serv. B.&W.
Lancashire, +.52
25 Corporation of Chain 600 132 8 200 57.2 280.4 1.3909 .52
Pa. +.19
N. J., Marion Grate
Pub. Serv. B.&W.
Lancashire, +.15
26 Corporation of Chain 600 132 8 199 60.7 171.0 1.3191 .52
Pa. .04
N. J., Marion Grate
Erie County B.&W.
Mercer
27 Electric Co., Chain 508 90 8 120 69.9 1.1888 .31 .58
County, Pa.
Erie, Pa. Grate
Union Elec. Lt. B.&W.
Mascouth,
28 & Pr. Co., St. Chain 508 103.5 8 180 46 113 1.2871 .62 1.24
Ill.
Louis, Mo. Grate
Union Elec. Lt. B.&W.
St. Clair
29 & Pr. Co., St. Chain 508 103.5 8 183 53.1 104 1.2725 .60 1.26
County, Ill.
Louis, Mo. Grate
Commonwealth Carterville, B.&W.
30 Edison Co., Ill., Chain 508 90 7 184 127.1 180 1.2393 .68 1.15
Chicago, Ill. Screenings Grate
[Pg 281]
TABLE 59—Part 2
TESTS OF BABCOCK & WILCOX BOILERS WITH VARIOUS FUELS
Coal Water
Equivalent
Dry
Evaporation
Coal
@ >=212°
Temperature Total Per
Equivalent per
of Weight Ash Square Actual
Number Total Evaporation Square
Flue of Moisture and Total Foot Evaporation
of Dry @ >=212° Foot
Gases Coal Per Refuse Combustible of per
Test Coal per of
degrees as Cent Per Pounds Grate Hour
Pounds Hour Heating
Fahrenheit Fired Cent Surface Pounds
Pounds Surface
Pounds per
per
Hour
Hour
Pounds
Pounds
1 11670 4.45 11151 26.05 8248 16.6 10268 12286 4.10
2 487 8800 7.62 8129 29.82 5705 19.71 8246 9466 4.34
3 559 10799 6.42 10106 20.02 8081 21.77 9145 10959 3.65
4 427 5088 4.00 4884 19.35 3939 15.26 5006 5599 3.61
5 414 9440 2.14 9238 11.19 8204 15.52 7434 8809 3.06
6 410 8555 3.62 8245 15.73 6948 17.28 2903 3454 2.91
7 480 7130 7.38 6604 18.35 5392 19.29 7464 8459 2.82
8 449 7500 2.70 7298 27.94 5259 14.73 9164 10787 2.88
9 410 15087 7.50 13956 11.30 12379 21.5 4374 5271 3.51
10 503 29528 7.72 27248 24.7 8688 10309 3.44
11 487 20400 2.84 19821 7.83 18269 21.00 24036 26829 4.19
12 494 21332 2.29 20843 8.23 19127 22.31 25313 28544 4.46
13 516 24584 4.29 23529 7.63 21883 18.85 9168 10990 3.42
14 523 15540 18.64 12643 28.59 11202 13689 3.91
15 474 18330 2.03 17958 16.36 16096 12.57 7565 8543 3.21
16 536 12243 2.14 11981 23.40 9512 11237 3.74
17 534 10500 3.04 10181 21.40 9257 11025 3.70
18 458 18600 3.40 17968 18.38 14665 17.41 15887 19614 3.77
19 609 23400 2.56 22801 16.89 18951 24.55 21320 26347 5.06
20 518 10500 1.83 10308 12.22 9048 21.56 9976 11978 3.93
21 536 25296 2.20 24736 41.0 28451 33066 5.47
22 511 14263 8.63 13032 10467 13526 4.51
23 560 39670 4.22 37996 4.32 36355 25.98 20700 26902 5.30
Page 389
24 538 23000 23.73 17542 21.36 14650 17583 4.40
25 590 32205 4.03 30907 15.65 26070 29.26 28906 40205 6.70
26 529 24243 4.09 23251 12.33 20385 22.01 23074 30437 5.07
27 533 22328 4.42 21341 16.88 17739 29.64 20759 24678 4.85
28 523 32163 13.74 27744 33.50 21998 28314 5.67
29 567 36150 14.62 30865 37.28 24386 31031 6.11
30 30610 11.12 27206 14.70 23198 43.20 30505 37805 7.43
TABLE 59—Part 3
TESTS OF BABCOCK & WILCOX BOILERS WITH VARIOUS
FUELS
Per Flue Gas Analysis Proximate Analysis Dry Coal Equivalent
Evaporation Combined
Cent
B.t.u. @ >=212° Efficiency
of
Number Volatile Fixed per per Boiler
Rated CO2 O CO Ash
of Pound and
Capacity Per Per Per Matter Carbon Per Pound
Test Per Per Dry of Grate
Developed Cent Cent Cent Cent
Cent Cent Coal Dry Per
Per
B.t.u. Coal Cent
Cent
Pounds
1 118.7 26.05 11913 8.81 71.8
2 125.7 11104 8.15 72.1
3 105.9 5.55 80.60 13.87 12300 8.67 68.4
4 104.7 12.26 7.88 0.0 7.74 77.48 14.78 12851 9.17 69.2
5 87.2 13138 9.53 69.6
6 84.4 6.13 84.86 9.01 13454 9.57 69.0
7 81.7 12224 8.97 71.2
8 83.5 0.55 86.73 12.72 12642 8.87 68.1
9 101.8 11.7 7.3 0.07 39.01 48.08 12.91 12292 9.06 71.5
10 99.6 12.9 5.0 0.2 38.33 46.71 14.96 12284 9.08 71.7
11 121.5 12.5 6.4 0.5 19.86 73.02 7.12 14602 10.83 72.0
12 129.3 13.3 5.1 0.5 20.24 72.26 7.50 14381 10.84 73.2
13 99.3 9.6 8.8 0.4 14955 11.21 72.7
14 113.5 9.1 9.9 0.0 39.60 54.46 5.94 11585 8.66 72.5
15 93.1 10.71 9.10 0.0 17.44 76.42 5.84 15379 11.42 72.1
16 108.6 33.40 54.73 11.87 12751 9.38 71.4
17 107.2 15.42 62.48 22.10 12060 8.66 69.6
18 108.7 11.7 7.7 0.0 14.99 75.13 9.88 14152 10.92 74.88
19 146.7 11.9 7.8 0.0 14.40 74.33 11.27 14022 10.40 71.97
20 112.0 11.3 7.5 0.0 32.44 56.71 10.85 13510 10.30 74.6
21 158.6 12.3 6.4 0.7 19.02 72.09 8.89 14105 10.69 73.5
22 130.7 11.9 7.2 0.04 32.11 53.93 13.96 12435 9.41 73.4
23 153.5 11.1 19.66 75.41 4.93 14910 11.51 74.9
24 127.4 43.57 46.22 10.21 11160 8.02 69.7
25 194.2 10.5 8.3 0.0 22.84 69.91 7.25 13840 10.41 72.6
26 147.0 10.1 9.0 0.0 32.36 60.67 6.97 14027 10.47 72.1
27 140.8 10.1 9.1 0.0 33.26 54.03 12.71 12742 9.25 70.4
28 161.5 8.7 10.6 0.0 28.96 46.88 24.16 10576 8.16 74.9
29 177.1 8.9 10.7 0.2 36.50 41.20 22.30 10849 8.04 71.9
30
215.7 10.4 9.4 0.2 10.24 13126 9.73 71.9
[Pg 282]
25 590 32205 4.03 30907 15.65 26070 29.26 28906 40205 6.70
26 529 24243 4.09 23251 12.33 20385 22.01 23074 30437 5.07
27 533 22328 4.42 21341 16.88 17739 29.64 20759 24678 4.85
28 523 32163 13.74 27744 33.50 21998 28314 5.67
29 567 36150 14.62 30865 37.28 24386 31031 6.11
30 30610 11.12 27206 14.70 23198 43.20 30505 37805 7.43
TABLE 59—Part 3
TESTS OF BABCOCK & WILCOX BOILERS WITH VARIOUS
FUELS
Per Flue Gas Analysis Proximate Analysis Dry Coal Equivalent
Evaporation Combined
Cent
B.t.u. @ >=212° Efficiency
of
Number Volatile Fixed per per Boiler
Rated CO2 O CO Ash
of Pound and
Capacity Per Per Per Matter Carbon Per Pound
Test Per Per Dry of Grate
Developed Cent Cent Cent Cent
Cent Cent Coal Dry Per
Per
B.t.u. Coal Cent
Cent
Pounds
1 118.7 26.05 11913 8.81 71.8
2 125.7 11104 8.15 72.1
3 105.9 5.55 80.60 13.87 12300 8.67 68.4
4 104.7 12.26 7.88 0.0 7.74 77.48 14.78 12851 9.17 69.2
5 87.2 13138 9.53 69.6
6 84.4 6.13 84.86 9.01 13454 9.57 69.0
7 81.7 12224 8.97 71.2
8 83.5 0.55 86.73 12.72 12642 8.87 68.1
9 101.8 11.7 7.3 0.07 39.01 48.08 12.91 12292 9.06 71.5
10 99.6 12.9 5.0 0.2 38.33 46.71 14.96 12284 9.08 71.7
11 121.5 12.5 6.4 0.5 19.86 73.02 7.12 14602 10.83 72.0
12 129.3 13.3 5.1 0.5 20.24 72.26 7.50 14381 10.84 73.2
13 99.3 9.6 8.8 0.4 14955 11.21 72.7
14 113.5 9.1 9.9 0.0 39.60 54.46 5.94 11585 8.66 72.5
15 93.1 10.71 9.10 0.0 17.44 76.42 5.84 15379 11.42 72.1
16 108.6 33.40 54.73 11.87 12751 9.38 71.4
17 107.2 15.42 62.48 22.10 12060 8.66 69.6
18 108.7 11.7 7.7 0.0 14.99 75.13 9.88 14152 10.92 74.88
19 146.7 11.9 7.8 0.0 14.40 74.33 11.27 14022 10.40 71.97
20 112.0 11.3 7.5 0.0 32.44 56.71 10.85 13510 10.30 74.6
21 158.6 12.3 6.4 0.7 19.02 72.09 8.89 14105 10.69 73.5
22 130.7 11.9 7.2 0.04 32.11 53.93 13.96 12435 9.41 73.4
23 153.5 11.1 19.66 75.41 4.93 14910 11.51 74.9
24 127.4 43.57 46.22 10.21 11160 8.02 69.7
25 194.2 10.5 8.3 0.0 22.84 69.91 7.25 13840 10.41 72.6
26 147.0 10.1 9.0 0.0 32.36 60.67 6.97 14027 10.47 72.1
27 140.8 10.1 9.1 0.0 33.26 54.03 12.71 12742 9.25 70.4
28 161.5 8.7 10.6 0.0 28.96 46.88 24.16 10576 8.16 74.9
29 177.1 8.9 10.7 0.2 36.50 41.20 22.30 10849 8.04 71.9
30
215.7 10.4 9.4 0.2 10.24 13126 9.73 71.9
[Pg 282]
Page 390
15400 Horse-power Installation of Babcock & Wilcox Boilers and Superheaters, Equipped with
Babcock & Wilcox Chain Grate Stokers at the Plant of the Twin City Rapid Transit Co.,
Minneapolis, Minn.
[Pg 283]
This increase in the efficiency of the boiler alone with the decrease in the rate at which it is operated, will
hold to a point where the radiation of heat from the boiler setting is proportionately large enough to be a
governing factor in the total amount of heat absorbed.
The second reason given above for a decrease of boiler efficiency with increase of capacity, viz., the effect
of radiant heat, is to a greater extent than the first reason dependent upon a constant furnace temperature.
Any increase in this temperature will affect enormously the amount of heat absorbed by radiation, as this
absorption will vary as the fourth power of the temperature of the radiating body. In this way it is seen that
but a slight increase in furnace temperature will be necessary to bring the proportional part, due to
absorption by radiation, of the total heat absorbed, up to its proper proportion at the higher ratings. This
factor of furnace temperature more properly belongs to the consideration of furnace efficiency than of
boiler efficiency. There is a point, however, in any furnace above which the combustion will be so poor as
to actually reduce the furnace temperature and, therefore, the proportion of heat absorbed through
radiation by a given amount of exposed heating surface.
Since it is thus true that the efficiency of the boiler considered alone will increase with a decreased
capacity, it is evident that if the furnace conditions are constant regardless of the load, that the combined
efficiency of boiler and furnace will also decrease with increasing loads. This fact was clearly proven in
the tests of the boilers at the Detroit Edison Company.[74] The furnace arrangement of these boilers and the
great care with which the tests were run made it possible to secure uniformly good furnace conditions
irrespective of load, and here the maximum efficiency was obtained at a point somewhat less than the
rated capacity of the boilers.
In some cases, however, and especially in the ordinary operation of the plant, the furnace efficiency will,
up to a certain point, increase with an increase in power. This increase in furnace efficiency is ordinarily at
Babcock & Wilcox Chain Grate Stokers at the Plant of the Twin City Rapid Transit Co.,
Minneapolis, Minn.
[Pg 283]
This increase in the efficiency of the boiler alone with the decrease in the rate at which it is operated, will
hold to a point where the radiation of heat from the boiler setting is proportionately large enough to be a
governing factor in the total amount of heat absorbed.
The second reason given above for a decrease of boiler efficiency with increase of capacity, viz., the effect
of radiant heat, is to a greater extent than the first reason dependent upon a constant furnace temperature.
Any increase in this temperature will affect enormously the amount of heat absorbed by radiation, as this
absorption will vary as the fourth power of the temperature of the radiating body. In this way it is seen that
but a slight increase in furnace temperature will be necessary to bring the proportional part, due to
absorption by radiation, of the total heat absorbed, up to its proper proportion at the higher ratings. This
factor of furnace temperature more properly belongs to the consideration of furnace efficiency than of
boiler efficiency. There is a point, however, in any furnace above which the combustion will be so poor as
to actually reduce the furnace temperature and, therefore, the proportion of heat absorbed through
radiation by a given amount of exposed heating surface.
Since it is thus true that the efficiency of the boiler considered alone will increase with a decreased
capacity, it is evident that if the furnace conditions are constant regardless of the load, that the combined
efficiency of boiler and furnace will also decrease with increasing loads. This fact was clearly proven in
the tests of the boilers at the Detroit Edison Company.[74] The furnace arrangement of these boilers and the
great care with which the tests were run made it possible to secure uniformly good furnace conditions
irrespective of load, and here the maximum efficiency was obtained at a point somewhat less than the
rated capacity of the boilers.
In some cases, however, and especially in the ordinary operation of the plant, the furnace efficiency will,
up to a certain point, increase with an increase in power. This increase in furnace efficiency is ordinarily at
Page 391
a greater rate as the capacity increases than is the decrease in boiler efficiency, with the result that the
combined efficiency of boiler and furnace will to a certain point increase with an increase in capacity. This
makes the ordinary point of maximum combined efficiency somewhat above the rated capacity of the
boiler and in many cases the combined efficiency will be practically a constant over a considerable range
of ratings. The features limiting the establishing of the point of maximum efficiency at a high rating are
the same as those limiting the amount of grate surface that can be installed under a boiler. The relative
efficiency of different combinations of boilers and furnaces at different ratings depends so largely upon
the furnace conditions that what might hold for one combination would not for another.
In view of the above, it is impossible to make a statement of the efficiency at different capacities of a
boiler and furnace which will hold for any and all conditions. Fig. 40 shows in a general form the relation
of efficiency to capacity. This curve has been plotted from a great number of tests, all of which were
corrected to bring them to approximately the same conditions. The curve represents test conditions. The
efficiencies represented are those which may be secured only under such conditions. The general direction
of the curve, however, will be found to hold approximately correct for operating conditions when used
only as a guide to what may be expected.
[Pg 284]
Fig. 40. Approximate Variation of Efficiency with Capacity under Test Conditions
Economical Loads—With the effect of capacity on economy in mind, the question arises as to what
constitutes the economical load to be carried. In figuring on the economical load for an individual plant,
the broader economy is to be considered, that in which, against the boiler efficiency, there is to be weighed
the plant first cost, returns on such investment, fuel cost, labor, capacity, etc., etc. This matter has been
widely discussed, but unfortunately such discussion has been largely limited to central power station
practice. The power generated in such stations, while representing an enormous total, is by no means the
larger proportion of the total power generated throughout the country. The factors determining the
economic load for the small plant, however, are the same as in a large, and in general the statements made
relative to the question are equally applicable.
The economical rating at which a boiler plant should be run is dependent solely upon the load to be
carried by that individual plant and the nature of such load. The economical load for each individual plant
can be determined only from the careful study of each individual set of conditions or by actual trial.
combined efficiency of boiler and furnace will to a certain point increase with an increase in capacity. This
makes the ordinary point of maximum combined efficiency somewhat above the rated capacity of the
boiler and in many cases the combined efficiency will be practically a constant over a considerable range
of ratings. The features limiting the establishing of the point of maximum efficiency at a high rating are
the same as those limiting the amount of grate surface that can be installed under a boiler. The relative
efficiency of different combinations of boilers and furnaces at different ratings depends so largely upon
the furnace conditions that what might hold for one combination would not for another.
In view of the above, it is impossible to make a statement of the efficiency at different capacities of a
boiler and furnace which will hold for any and all conditions. Fig. 40 shows in a general form the relation
of efficiency to capacity. This curve has been plotted from a great number of tests, all of which were
corrected to bring them to approximately the same conditions. The curve represents test conditions. The
efficiencies represented are those which may be secured only under such conditions. The general direction
of the curve, however, will be found to hold approximately correct for operating conditions when used
only as a guide to what may be expected.
[Pg 284]
Fig. 40. Approximate Variation of Efficiency with Capacity under Test Conditions
Economical Loads—With the effect of capacity on economy in mind, the question arises as to what
constitutes the economical load to be carried. In figuring on the economical load for an individual plant,
the broader economy is to be considered, that in which, against the boiler efficiency, there is to be weighed
the plant first cost, returns on such investment, fuel cost, labor, capacity, etc., etc. This matter has been
widely discussed, but unfortunately such discussion has been largely limited to central power station
practice. The power generated in such stations, while representing an enormous total, is by no means the
larger proportion of the total power generated throughout the country. The factors determining the
economic load for the small plant, however, are the same as in a large, and in general the statements made
relative to the question are equally applicable.
The economical rating at which a boiler plant should be run is dependent solely upon the load to be
carried by that individual plant and the nature of such load. The economical load for each individual plant
can be determined only from the careful study of each individual set of conditions or by actual trial.
Page 392
The controlling factor in the cost of the plant, regardless of the nature of the load, is the capacity to carry
the maximum peak load that may be thrown on the plant under any conditions.
While load conditions, do, as stated, vary in every individual plant, in a broad sense all loads may be
grouped in three classes: 1st, the approximately constant 24-hour load; 2nd, the steady 10 or 12-hour load
usually with a noonday period of no load; 3rd, the 24-hour variable load, found in central station practice.
The economical load at which the boiler may be run will vary with these groups:
1st. For a constant load, 24 hours in the day, it will be found in most cases that, when all features are
considered, the most economical load or that at which a given amount of steam can be produced the most
cheaply will be considerably over the rated horse power of the boiler. How much above the rated capacity
this most economic load will be, is dependent largely upon the cost of coal at the plant, but under ordinary
conditions, the point of maximum economy will probably be found to be somewhere [Pg 285] between 25
and 50 per cent above the rated capacity of the boilers. The capital investment must be weighed against
the coal saving through increased thermal efficiency and the labor account, which increases with the
number of units, must be given proper consideration. When the question is considered in connection with
a plant already installed, the conditions are different from where a new plant is contemplated. In an old
plant, where there are enough boilers to operate at low rates of capacity, the capital investment leads to a
fixed charge, and it will be found that the most economical load at which boilers may be operated will be
lower than where a new plant is under consideration.
2nd. For a load of 10 or 12 hours a day, either an approximately steady load or one in which there is a
peak, where the boilers have been banked over night, the capacity at which they may be run with the best
economy will be found to be higher than for uniform 24-hour load conditions. This is obviously due to
original investment, that is, a given amount of invested capital can be made to earn a larger return through
the higher overload, and this will hold true to a point where the added return more than offsets the
decrease in actual boiler efficiency. Here again the determining factors of what is the economical load are
the fuel and labor cost balanced against the thermal efficiency. With a load of this character, there is
another factor which may affect the economical plant operating load. This is from the viewpoint of spare
boilers. That such added capacity in the way of spares is necessary is unquestionable. Since they must be
installed, therefore, their presence leads to a fixed charge and it is probable that for the plant, as a whole,
the economical load will be somewhat lower than if the boilers were considered only as spares. That is, it
may be found best to operate these spares as a part of the regular equipment at all times except when other
boilers are off for cleaning and repairs, thus reducing the load on the individual boilers and increasing the
efficiency. Under such conditions, the added boiler units can be considered as spares only during such
time as some of the boilers are not in operation.
Due to the operating difficulties that may be encountered at the higher overloads, it will ordinarily be
found that the most economical ratings at which to run boilers for such load conditions will be between
150 and 175 per cent of rating. Here again the maximum capacity at which the boilers may be run for the
best plant economy is limited by the point at which the efficiency drops below what is warranted in view
of the first cost of the apparatus.
3rd. The 24-hour variable load. This is a class of load carried by the central power station, a load constant
only in the sense that there are no periods of no load and which varies widely with different portions of the
24 hours. With such a load it is particularly difficult to make any assertion as to the point of maximum
economy that will hold for any station, as this point is more than with any other class of load dependent
upon the factors entering into the operation of each individual plant.
The methods of handling a load of this description vary probably more than with any other kind of load,
dependent upon fuel, labor, type of stoker, flexibility of combined furnace and boiler etc., etc.
the maximum peak load that may be thrown on the plant under any conditions.
While load conditions, do, as stated, vary in every individual plant, in a broad sense all loads may be
grouped in three classes: 1st, the approximately constant 24-hour load; 2nd, the steady 10 or 12-hour load
usually with a noonday period of no load; 3rd, the 24-hour variable load, found in central station practice.
The economical load at which the boiler may be run will vary with these groups:
1st. For a constant load, 24 hours in the day, it will be found in most cases that, when all features are
considered, the most economical load or that at which a given amount of steam can be produced the most
cheaply will be considerably over the rated horse power of the boiler. How much above the rated capacity
this most economic load will be, is dependent largely upon the cost of coal at the plant, but under ordinary
conditions, the point of maximum economy will probably be found to be somewhere [Pg 285] between 25
and 50 per cent above the rated capacity of the boilers. The capital investment must be weighed against
the coal saving through increased thermal efficiency and the labor account, which increases with the
number of units, must be given proper consideration. When the question is considered in connection with
a plant already installed, the conditions are different from where a new plant is contemplated. In an old
plant, where there are enough boilers to operate at low rates of capacity, the capital investment leads to a
fixed charge, and it will be found that the most economical load at which boilers may be operated will be
lower than where a new plant is under consideration.
2nd. For a load of 10 or 12 hours a day, either an approximately steady load or one in which there is a
peak, where the boilers have been banked over night, the capacity at which they may be run with the best
economy will be found to be higher than for uniform 24-hour load conditions. This is obviously due to
original investment, that is, a given amount of invested capital can be made to earn a larger return through
the higher overload, and this will hold true to a point where the added return more than offsets the
decrease in actual boiler efficiency. Here again the determining factors of what is the economical load are
the fuel and labor cost balanced against the thermal efficiency. With a load of this character, there is
another factor which may affect the economical plant operating load. This is from the viewpoint of spare
boilers. That such added capacity in the way of spares is necessary is unquestionable. Since they must be
installed, therefore, their presence leads to a fixed charge and it is probable that for the plant, as a whole,
the economical load will be somewhat lower than if the boilers were considered only as spares. That is, it
may be found best to operate these spares as a part of the regular equipment at all times except when other
boilers are off for cleaning and repairs, thus reducing the load on the individual boilers and increasing the
efficiency. Under such conditions, the added boiler units can be considered as spares only during such
time as some of the boilers are not in operation.
Due to the operating difficulties that may be encountered at the higher overloads, it will ordinarily be
found that the most economical ratings at which to run boilers for such load conditions will be between
150 and 175 per cent of rating. Here again the maximum capacity at which the boilers may be run for the
best plant economy is limited by the point at which the efficiency drops below what is warranted in view
of the first cost of the apparatus.
3rd. The 24-hour variable load. This is a class of load carried by the central power station, a load constant
only in the sense that there are no periods of no load and which varies widely with different portions of the
24 hours. With such a load it is particularly difficult to make any assertion as to the point of maximum
economy that will hold for any station, as this point is more than with any other class of load dependent
upon the factors entering into the operation of each individual plant.
The methods of handling a load of this description vary probably more than with any other kind of load,
dependent upon fuel, labor, type of stoker, flexibility of combined furnace and boiler etc., etc.
Page 393
In general, under ordinary conditions such as appear in city central power station work where the
maximum peaks occur but a few times a year, the plant should be made of such size as to enable it to carry
these peaks at the maximum possible overload on the boilers, sufficient margin of course being allowed
for insurance against interruption of [Pg 286]
[Pg 287] service. With the boilers operating at this maximum overload through the peaks a large sacrifice in
boiler efficiency is allowable, provided that by such sacrifice the overload expected is secured.
Portion of 4890 Horse-power Installation of Babcock & Wilcox Boilers at the Billings Sugar Co.,
Billings, Mont. 694 Horse Power of these Boilers are Equipped with Babcock and Wilcox Chain
Grate Stokers
Some methods of handling a load of this nature are given below:
Certain plant operating conditions make it advisable, from the standpoint of plant economy, to carry
whatever load is on the plant at any time on only such boilers as will furnish the power required when
operating at ratings of, say, 150 to 200 per cent. That is, all boilers which are in service are operated at
such ratings at all times, the variation in load being taken care of by the number of boilers on the line.
Banked boilers are cut in to take care of increasing loads and peaks and placed again on bank when the
peak periods have passed. It is probable that this method of handling central station load is to-day the most
generally used.
Other conditions of operation make it advisable to carry the load on a definite number of boiler units,
operating these at slightly below their rated capacity during periods of light or low loads and securing the
overload capacity during peaks by operating the same boilers at high ratings. In this method there are no
boilers kept on banked fires, the spares being spares in every sense of the word.
A third method of handling widely varying loads which is coming somewhat into vogue is that of
considering the plant as divided, one part to take care of what may be considered the constant plant load,
the other to take care of the floating or variable load. With such a method that portion of the plant carrying
the steady load is so proportioned that the boilers may be operated at the point of maximum efficiency,
this point being raised to a maximum through the use of economizers and the general installation of any
maximum peaks occur but a few times a year, the plant should be made of such size as to enable it to carry
these peaks at the maximum possible overload on the boilers, sufficient margin of course being allowed
for insurance against interruption of [Pg 286]
[Pg 287] service. With the boilers operating at this maximum overload through the peaks a large sacrifice in
boiler efficiency is allowable, provided that by such sacrifice the overload expected is secured.
Portion of 4890 Horse-power Installation of Babcock & Wilcox Boilers at the Billings Sugar Co.,
Billings, Mont. 694 Horse Power of these Boilers are Equipped with Babcock and Wilcox Chain
Grate Stokers
Some methods of handling a load of this nature are given below:
Certain plant operating conditions make it advisable, from the standpoint of plant economy, to carry
whatever load is on the plant at any time on only such boilers as will furnish the power required when
operating at ratings of, say, 150 to 200 per cent. That is, all boilers which are in service are operated at
such ratings at all times, the variation in load being taken care of by the number of boilers on the line.
Banked boilers are cut in to take care of increasing loads and peaks and placed again on bank when the
peak periods have passed. It is probable that this method of handling central station load is to-day the most
generally used.
Other conditions of operation make it advisable to carry the load on a definite number of boiler units,
operating these at slightly below their rated capacity during periods of light or low loads and securing the
overload capacity during peaks by operating the same boilers at high ratings. In this method there are no
boilers kept on banked fires, the spares being spares in every sense of the word.
A third method of handling widely varying loads which is coming somewhat into vogue is that of
considering the plant as divided, one part to take care of what may be considered the constant plant load,
the other to take care of the floating or variable load. With such a method that portion of the plant carrying
the steady load is so proportioned that the boilers may be operated at the point of maximum efficiency,
this point being raised to a maximum through the use of economizers and the general installation of any
Page 394
apparatus leading to such results. The variable load will be carried on the remaining boilers of the plant
under either of the methods just given, that is, at the high ratings of all boilers in service and banking
others, or a variable capacity from all boilers in service.
The opportunity is again taken to indicate the very general character of any statements made relative to the
economical load for any plant and to emphasize the fact that each individual case must be considered
independently, with the conditions of operations applicable thereto.
With a thorough understanding of the meaning of boiler efficiency and capacity and their relation to each
other, it is possible to consider more specifically the selection of boilers.
The foremost consideration is, without question, the adaptability of the design selected to the nature of the
work to be done. An installation which is only temporary in its nature would obviously not warrant the
first cost that a permanent plant would. If boilers are to carry an intermittent and suddenly fluctuating
load, such as a hoisting load or a reversing mill load, a design would have to be selected that would not
tend to prime with the fluctuations and sudden demand for steam. A boiler that would give the highest
possible efficiency with fuel of one description, would not of necessity give such efficiency with a
different fuel. A boiler of a certain design which might be good for small plant practice would not, because
of the limitations in practicable size of units, be suitable for large installations. A discussion of the relative
value of designs can be carried on almost indefinitely but enough has been said to indicate that a given
design will not serve satisfactorily under all conditions and that the adaptability to the service required
will be dependent upon the fuel available, the class of labor procurable, the feed water that must be used,
the nature of the plant’s load, the size of the plant and the first cost warranted by the service the boiler is to
fulfill.
[Pg 288]
TABLE 60
ACTUAL EVAPORATION FOR DIFFERENT PRESSURES AND TEMPERATURES OF FEED
WATER
CORRESPONDING TO ONE HORSE POWER (34½ POUNDS PER HOUR FROM AND AT 212 DEGREES FAHRENHEIT)
Temperature
of Pressure by Gauge—Pounds per Square Inch
Feed
Degrees 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250
Fahrenheit
32 28.41 28.36 28.29 28.24 28.20 28.16 28.13 28.09 28.07 28.04 28.02 27.99 27.97 27.95 27.94 27.92 27.90 27.89 27.87 27.86 27.83
40 28.61 28.54 28.49 28.44 28.40 28.35 28.32 28.29 28.26 28.23 28.21 28.18 28.16 28.14 28.12 28.11 28.09 28.07 28.06 28.05 28.03
50 28.85 28.79 28.73 28.68 28.64 28.60 28.56 28.53 28.50 28.47 28.45 28.43 28.40 28.38 28.36 28.35 28.33 28.31 28.30 28.28 28.27
60 29.10 29.04 28.98 28.93 28.88 28.84 28.81 28.77 28.74 28.72 28.69 28.67 28.65 28.62 28.60 28.59 28.57 28.55 28.54 28.52 28.51
70 29.36 29.29 29.23 29.18 29.14 29.09 29.06 29.02 28.99 28.96 28.94 28.92 28.89 28.87 28.85 28.83 28.82 28.80 28.78 28.77 28.76
80 29.62 29.55 29.49 29.44 29.39 29.35 29.31 29.27 29.24 29.22 29.19 29.17 29.14 29.12 29.10 29.08 29.07 29.05 29.03 29.02 29.00
90 29.88 29.81 29.75 29.70 29.65 29.61 29.57 29.53 29.50 29.47 29.45 29.42 29.40 29.38 29.36 29.34 29.32 29.30 29.29 29.27 29.25
100 30.15 30.08 30.02 29.96 29.91 29.87 29.83 29.80 29.76 29.73 29.71 29.68 29.66 29.63 29.61 29.60 29.58 29.56 29.54 29.53 29.51
110 30.42 30.35 30.29 30.23 30.18 30.14 30.10 30.06 30.03 30.00 29.97 29.95 29.92 29.90 29.88 29.86 29.84 29.82 29.81 29.79 29.77
120 30.70 30.63 30.56 30.51 30.46 30.41 30.37 30.33 30.30 30.27 30.24 30.22 30.19 30.17 30.15 30.13 30.11 30.09 30.07 30.06 30.04
130 30.99 30.91 30.84 30.79 30.73 30.69 30.65 30.61 30.57 30.54 30.52 30.49 30.47 30.44 30.42 30.40 30.38 30.36 30.35 30.33 30.31
140 31.28 31.20 31.13 31.07 31.02 30.97 30.93 30.89 30.86 30.83 30.80 30.77 30.75 30.72 30.70 30.68 30.66 30.64 30.62 30.61 30.59
150 31.58 31.49 31.42 31.36 31.31 31.26 31.22 31.18 31.14 31.11 31.08 31.06 31.03 31.01 30.98 30.96 30.94 30.92 30.91 30.89 30.87
160 31.87 31.79 31.72 31.66 31.61 31.56 31.51 31.47 31.44 31.40 31.37 31.35 31.32 31.29 31.27 31.25 31.23 31.21 31.19 31.18 31.16
170 32.18 32.10 32.02 31.96 31.91 31.86 31.81 31.77 31.73 31.70 31.67 31.64 31.62 31.59 31.57 31.54 31.52 31.50 31.49 31.47 31.46
180 32.49 32.41 32.33 32.27 32.22 32.16 32.12 32.08 32.04 32.00 31.97 31.95 31.92 31.89 31.87 31.84 31.82 31.80 31.79 31.77 31.75
190 32.81 32.72 32.65 32.59 32.53 32.47 32.43 32.38 32.35 32.32 32.29 32.26 32.23 32.20 32.17 32.15 32.13 32.11 32.09 32.07 32.05
200 33.13 33.05 32.97 32.91 32.85 32.79 32.75 32.70 32.66 32.63 32.60 32.57 32.54 32.51 32.49 32.46 32.44 32.42 32.40 32.38 32.36
210 33.47 33.38 33.30 33.24 33.18 33.13 33.08 33.03 32.99 32.95 32.92 32.89 32.86 32.83 32.81 32.79 32.76 32.74 32.72 32.70 32.68
under either of the methods just given, that is, at the high ratings of all boilers in service and banking
others, or a variable capacity from all boilers in service.
The opportunity is again taken to indicate the very general character of any statements made relative to the
economical load for any plant and to emphasize the fact that each individual case must be considered
independently, with the conditions of operations applicable thereto.
With a thorough understanding of the meaning of boiler efficiency and capacity and their relation to each
other, it is possible to consider more specifically the selection of boilers.
The foremost consideration is, without question, the adaptability of the design selected to the nature of the
work to be done. An installation which is only temporary in its nature would obviously not warrant the
first cost that a permanent plant would. If boilers are to carry an intermittent and suddenly fluctuating
load, such as a hoisting load or a reversing mill load, a design would have to be selected that would not
tend to prime with the fluctuations and sudden demand for steam. A boiler that would give the highest
possible efficiency with fuel of one description, would not of necessity give such efficiency with a
different fuel. A boiler of a certain design which might be good for small plant practice would not, because
of the limitations in practicable size of units, be suitable for large installations. A discussion of the relative
value of designs can be carried on almost indefinitely but enough has been said to indicate that a given
design will not serve satisfactorily under all conditions and that the adaptability to the service required
will be dependent upon the fuel available, the class of labor procurable, the feed water that must be used,
the nature of the plant’s load, the size of the plant and the first cost warranted by the service the boiler is to
fulfill.
[Pg 288]
TABLE 60
ACTUAL EVAPORATION FOR DIFFERENT PRESSURES AND TEMPERATURES OF FEED
WATER
CORRESPONDING TO ONE HORSE POWER (34½ POUNDS PER HOUR FROM AND AT 212 DEGREES FAHRENHEIT)
Temperature
of Pressure by Gauge—Pounds per Square Inch
Feed
Degrees 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250
Fahrenheit
32 28.41 28.36 28.29 28.24 28.20 28.16 28.13 28.09 28.07 28.04 28.02 27.99 27.97 27.95 27.94 27.92 27.90 27.89 27.87 27.86 27.83
40 28.61 28.54 28.49 28.44 28.40 28.35 28.32 28.29 28.26 28.23 28.21 28.18 28.16 28.14 28.12 28.11 28.09 28.07 28.06 28.05 28.03
50 28.85 28.79 28.73 28.68 28.64 28.60 28.56 28.53 28.50 28.47 28.45 28.43 28.40 28.38 28.36 28.35 28.33 28.31 28.30 28.28 28.27
60 29.10 29.04 28.98 28.93 28.88 28.84 28.81 28.77 28.74 28.72 28.69 28.67 28.65 28.62 28.60 28.59 28.57 28.55 28.54 28.52 28.51
70 29.36 29.29 29.23 29.18 29.14 29.09 29.06 29.02 28.99 28.96 28.94 28.92 28.89 28.87 28.85 28.83 28.82 28.80 28.78 28.77 28.76
80 29.62 29.55 29.49 29.44 29.39 29.35 29.31 29.27 29.24 29.22 29.19 29.17 29.14 29.12 29.10 29.08 29.07 29.05 29.03 29.02 29.00
90 29.88 29.81 29.75 29.70 29.65 29.61 29.57 29.53 29.50 29.47 29.45 29.42 29.40 29.38 29.36 29.34 29.32 29.30 29.29 29.27 29.25
100 30.15 30.08 30.02 29.96 29.91 29.87 29.83 29.80 29.76 29.73 29.71 29.68 29.66 29.63 29.61 29.60 29.58 29.56 29.54 29.53 29.51
110 30.42 30.35 30.29 30.23 30.18 30.14 30.10 30.06 30.03 30.00 29.97 29.95 29.92 29.90 29.88 29.86 29.84 29.82 29.81 29.79 29.77
120 30.70 30.63 30.56 30.51 30.46 30.41 30.37 30.33 30.30 30.27 30.24 30.22 30.19 30.17 30.15 30.13 30.11 30.09 30.07 30.06 30.04
130 30.99 30.91 30.84 30.79 30.73 30.69 30.65 30.61 30.57 30.54 30.52 30.49 30.47 30.44 30.42 30.40 30.38 30.36 30.35 30.33 30.31
140 31.28 31.20 31.13 31.07 31.02 30.97 30.93 30.89 30.86 30.83 30.80 30.77 30.75 30.72 30.70 30.68 30.66 30.64 30.62 30.61 30.59
150 31.58 31.49 31.42 31.36 31.31 31.26 31.22 31.18 31.14 31.11 31.08 31.06 31.03 31.01 30.98 30.96 30.94 30.92 30.91 30.89 30.87
160 31.87 31.79 31.72 31.66 31.61 31.56 31.51 31.47 31.44 31.40 31.37 31.35 31.32 31.29 31.27 31.25 31.23 31.21 31.19 31.18 31.16
170 32.18 32.10 32.02 31.96 31.91 31.86 31.81 31.77 31.73 31.70 31.67 31.64 31.62 31.59 31.57 31.54 31.52 31.50 31.49 31.47 31.46
180 32.49 32.41 32.33 32.27 32.22 32.16 32.12 32.08 32.04 32.00 31.97 31.95 31.92 31.89 31.87 31.84 31.82 31.80 31.79 31.77 31.75
190 32.81 32.72 32.65 32.59 32.53 32.47 32.43 32.38 32.35 32.32 32.29 32.26 32.23 32.20 32.17 32.15 32.13 32.11 32.09 32.07 32.05
200 33.13 33.05 32.97 32.91 32.85 32.79 32.75 32.70 32.66 32.63 32.60 32.57 32.54 32.51 32.49 32.46 32.44 32.42 32.40 32.38 32.36
210 33.47 33.38 33.30 33.24 33.18 33.13 33.08 33.03 32.99 32.95 32.92 32.89 32.86 32.83 32.81 32.79 32.76 32.74 32.72 32.70 32.68
Page 395
[Pg 289]
The proper consideration can be given to the adaptability of any boiler for the service in view only after a
thorough understanding of the requirements of a good steam boiler, with the application of what has been
said on the proper operation to the special requirements of each case. Of almost equal importance to the
factors mentioned are the experience, the skill and responsibility of the manufacturer.
With the design of boiler selected that is best adapted to the service required, the next step is the
determination of the boiler power requirements.
The amount of steam that must be generated is determined from the steam consumption of the prime
movers. It has already been indicated that such consumption can vary over wide limits with the size and
type of the apparatus used, but fortunately all types have been so tested that manufacturers are enabled to
state within very close limits the actual consumption under any given set of conditions. It is obvious that
conditions of operation will have a bearing on the steam consumption that is as important as the type and
size of the apparatus itself. This being the case, any tabular information that can be given on such steam
consumption, unless it be extended to an impracticable size, is only of use for the most approximate work
and more definite figures on this consumption should in all cases be obtained from the manufacturer of the
apparatus to be used for the conditions under which it will operate.
To the steam consumption of the main prime movers, there is to be added that of the auxiliaries. Again it is
impossible to make a definite statement of what this allowance should be, the figure depending wholly
upon the type and the number of such auxiliaries. For approximate work, it is perhaps best to allow 15 or
20 per cent of the steam requirements of the main engines, for that of auxiliaries. Whatever figure is used
should be taken high enough to be on the conservative side.
When any such figures are based on the actual weight of steam required, Table 60, which gives the actual
evaporation for various pressures and temperatures of feed corresponding to one boiler horse power (34.5
pounds of water per hour from and at 212 degrees), may be of service.
With the steam requirements known, the next step is the determination of the number and size of boiler
units to be installed. This is directly affected by the capacity at which a consideration of the economical
load indicates is the best for the operating conditions which will exist. The other factors entering into such
determination are the size of the plant and the character of the feed water.
The size of the plant has its bearing on the question from the fact that higher efficiencies are in general
obtained from large units, that labor cost decreases with the number of units, the first cost of brickwork is
lower for large than for small size units, a general decrease in the complication of piping, etc., and in
general the cost per horse power of any design of boiler decreases with the size of units. To illustrate this,
it is only necessary to consider a plant of, say, 10,000 boiler horse power, consisting of 40-250 horse-
power units or 17-600 horse-power units.
The feed water available has its bearing on the subject from the other side, for it has already been shown
that very large units are not advisable where the feed water is not of the best.
[Pg 290]
The character of an installment is also a factor. Where, say, 1000 horse power is installed in a plant where
it is known what the ultimate capacity is to be, the size of units should be selected with the idea of this
ultimate capacity in mind rather than the amount of the first installation.
Boiler service, from its nature, is severe. All boilers have to be cleaned from time to time and certain
repairs to settings, etc., are a necessity. This makes it necessary, in determining the number of boilers to be
The proper consideration can be given to the adaptability of any boiler for the service in view only after a
thorough understanding of the requirements of a good steam boiler, with the application of what has been
said on the proper operation to the special requirements of each case. Of almost equal importance to the
factors mentioned are the experience, the skill and responsibility of the manufacturer.
With the design of boiler selected that is best adapted to the service required, the next step is the
determination of the boiler power requirements.
The amount of steam that must be generated is determined from the steam consumption of the prime
movers. It has already been indicated that such consumption can vary over wide limits with the size and
type of the apparatus used, but fortunately all types have been so tested that manufacturers are enabled to
state within very close limits the actual consumption under any given set of conditions. It is obvious that
conditions of operation will have a bearing on the steam consumption that is as important as the type and
size of the apparatus itself. This being the case, any tabular information that can be given on such steam
consumption, unless it be extended to an impracticable size, is only of use for the most approximate work
and more definite figures on this consumption should in all cases be obtained from the manufacturer of the
apparatus to be used for the conditions under which it will operate.
To the steam consumption of the main prime movers, there is to be added that of the auxiliaries. Again it is
impossible to make a definite statement of what this allowance should be, the figure depending wholly
upon the type and the number of such auxiliaries. For approximate work, it is perhaps best to allow 15 or
20 per cent of the steam requirements of the main engines, for that of auxiliaries. Whatever figure is used
should be taken high enough to be on the conservative side.
When any such figures are based on the actual weight of steam required, Table 60, which gives the actual
evaporation for various pressures and temperatures of feed corresponding to one boiler horse power (34.5
pounds of water per hour from and at 212 degrees), may be of service.
With the steam requirements known, the next step is the determination of the number and size of boiler
units to be installed. This is directly affected by the capacity at which a consideration of the economical
load indicates is the best for the operating conditions which will exist. The other factors entering into such
determination are the size of the plant and the character of the feed water.
The size of the plant has its bearing on the question from the fact that higher efficiencies are in general
obtained from large units, that labor cost decreases with the number of units, the first cost of brickwork is
lower for large than for small size units, a general decrease in the complication of piping, etc., and in
general the cost per horse power of any design of boiler decreases with the size of units. To illustrate this,
it is only necessary to consider a plant of, say, 10,000 boiler horse power, consisting of 40-250 horse-
power units or 17-600 horse-power units.
The feed water available has its bearing on the subject from the other side, for it has already been shown
that very large units are not advisable where the feed water is not of the best.
[Pg 290]
The character of an installment is also a factor. Where, say, 1000 horse power is installed in a plant where
it is known what the ultimate capacity is to be, the size of units should be selected with the idea of this
ultimate capacity in mind rather than the amount of the first installation.
Boiler service, from its nature, is severe. All boilers have to be cleaned from time to time and certain
repairs to settings, etc., are a necessity. This makes it necessary, in determining the number of boilers to be
Page 396
installed, to allow a certain number of units or spares to be operated when any of the regular boilers must
be taken off the line. With the steam requirements determined for a plant of moderate size and a
reasonably constant load, it is highly advisable to install at least two spare boilers where a continuity of
service is essential. This permits the taking off of one boiler for cleaning or repairs and still allows a spare
boiler in the event of some unforeseen occurrence, such as the blowing out of a tube or the like.
Investment in such spare apparatus is nothing more nor less than insurance on the necessary continuity of
service. In small plants of, say, 500 or 600 horse power, two spares are not usually warranted in view of
the cost of such insurance. A large plant is ordinarily laid out in a number of sections or panels and each
section should have its spare boiler or boilers even though the sections are cross connected. In central
station work, where the peaks are carried on the boilers brought up from the bank, such spares are, of
course, in addition to these banked boilers. From the aspect of cleaning boilers alone, the number of spare
boilers is determined by the nature of any scale that may be formed. If scale is formed so rapidly that the
boilers cannot be kept clean enough for good operating results, by cleaning in rotation, one at a time, the
number of spares to take care of such proper cleaning will naturally increase.
In view of the above, it is evident that only a suggestion can be made as to the number and size of units, as
no recommendation will hold for all cases. In general, it will be found best to install units of the largest
possible size compatible with the size of the plant and operating conditions, with the total power
requirements divided among such a number of units as will give proper flexibility of load, with such
additional units for spares as conditions of cleaning and insurance against interruption of service warrant.
In closing the subject of the selection of boilers, it may not be out of place to refer to the effect of the
builder’s guarantee upon the determination of design to be used. Here in one of its most important aspects
appears the responsibility of the manufacturer. Emphasis has been laid on the difference between test
results and those secured in ordinary operating practice. That such a difference exists is well known and it
is now pretty generally realized that it is the responsible manufacturer who, where guarantees are
necessary, submits the conservative figures, figures which may readily be exceeded under test conditions
and which may be closely approached under the ordinary plant conditions that will be met in daily
operation.
FOOTNOTES
[74] See Transactions, A. S. M. E., Volume XXXIII, 1912.
be taken off the line. With the steam requirements determined for a plant of moderate size and a
reasonably constant load, it is highly advisable to install at least two spare boilers where a continuity of
service is essential. This permits the taking off of one boiler for cleaning or repairs and still allows a spare
boiler in the event of some unforeseen occurrence, such as the blowing out of a tube or the like.
Investment in such spare apparatus is nothing more nor less than insurance on the necessary continuity of
service. In small plants of, say, 500 or 600 horse power, two spares are not usually warranted in view of
the cost of such insurance. A large plant is ordinarily laid out in a number of sections or panels and each
section should have its spare boiler or boilers even though the sections are cross connected. In central
station work, where the peaks are carried on the boilers brought up from the bank, such spares are, of
course, in addition to these banked boilers. From the aspect of cleaning boilers alone, the number of spare
boilers is determined by the nature of any scale that may be formed. If scale is formed so rapidly that the
boilers cannot be kept clean enough for good operating results, by cleaning in rotation, one at a time, the
number of spares to take care of such proper cleaning will naturally increase.
In view of the above, it is evident that only a suggestion can be made as to the number and size of units, as
no recommendation will hold for all cases. In general, it will be found best to install units of the largest
possible size compatible with the size of the plant and operating conditions, with the total power
requirements divided among such a number of units as will give proper flexibility of load, with such
additional units for spares as conditions of cleaning and insurance against interruption of service warrant.
In closing the subject of the selection of boilers, it may not be out of place to refer to the effect of the
builder’s guarantee upon the determination of design to be used. Here in one of its most important aspects
appears the responsibility of the manufacturer. Emphasis has been laid on the difference between test
results and those secured in ordinary operating practice. That such a difference exists is well known and it
is now pretty generally realized that it is the responsible manufacturer who, where guarantees are
necessary, submits the conservative figures, figures which may readily be exceeded under test conditions
and which may be closely approached under the ordinary plant conditions that will be met in daily
operation.
FOOTNOTES
[74] See Transactions, A. S. M. E., Volume XXXIII, 1912.
Page 397
[Pg 291]
Page 398
OPERATION AND CARE OF BOILERS
The general subject of boiler room practice may be considered from two
aspects. The first is that of the broad plant economy, with a suggestion as to
the methods to be followed in securing the best economical results with the
apparatus at hand and procurable. The second deals rather with specific
recommendations which should be followed in plant practice,
recommendations leading not only to economy but also to safety and
continuity of service. Such recommendations are dictated from an
understanding of the nature of steam generating apparatus and its operation,
as covered previously in this book.
It has already been pointed out that the attention given in recent years to
steam generating practice has come with a realization of the wide difference
existing between the results being obtained in every-day operation and those
theoretically possible. The amount of such attention and regulation given to
the steam generating end of a power plant, however, is comparatively small
in relation to that given to the balance of the plant, but it may be safely
stated that it is here that there is the greatest assurance of a return for the
attention given.
In the endeavor to increase boiler room efficiency, it is of the utmost
importance that a standard basis be set by which average results are to be
judged. With the theoretical efficiency obtainable varying so widely, this
standard cannot be placed at the highest efficiency that has been obtained
regardless of operating conditions. It is better set at the best obtainable
results for each individual plant under its conditions of installation and daily
operation.
With an individual standard so set, present practice can only be improved by
a systematic effort to approach this standard. The degree with which
operating results will approximate such a standard will be found to be
directly proportional to the amount of intelligent supervision given the
operation. For such supervision to be given, it is necessary to have not only a
full realization of what the plant can do under the best operating conditions
The general subject of boiler room practice may be considered from two
aspects. The first is that of the broad plant economy, with a suggestion as to
the methods to be followed in securing the best economical results with the
apparatus at hand and procurable. The second deals rather with specific
recommendations which should be followed in plant practice,
recommendations leading not only to economy but also to safety and
continuity of service. Such recommendations are dictated from an
understanding of the nature of steam generating apparatus and its operation,
as covered previously in this book.
It has already been pointed out that the attention given in recent years to
steam generating practice has come with a realization of the wide difference
existing between the results being obtained in every-day operation and those
theoretically possible. The amount of such attention and regulation given to
the steam generating end of a power plant, however, is comparatively small
in relation to that given to the balance of the plant, but it may be safely
stated that it is here that there is the greatest assurance of a return for the
attention given.
In the endeavor to increase boiler room efficiency, it is of the utmost
importance that a standard basis be set by which average results are to be
judged. With the theoretical efficiency obtainable varying so widely, this
standard cannot be placed at the highest efficiency that has been obtained
regardless of operating conditions. It is better set at the best obtainable
results for each individual plant under its conditions of installation and daily
operation.
With an individual standard so set, present practice can only be improved by
a systematic effort to approach this standard. The degree with which
operating results will approximate such a standard will be found to be
directly proportional to the amount of intelligent supervision given the
operation. For such supervision to be given, it is necessary to have not only a
full realization of what the plant can do under the best operating conditions
Page 399
but also a full and complete knowledge of what it is doing under all of the
different conditions that may arise. What the plant is doing should be made a
matter of continuous record so arranged that the results may be directly
compared for any period or set of conditions, and where such results vary
from the standard set, steps must be taken immediately to remedy the causes
of such failings. Such a record is an important check in the losses in the
plant.
As the size of the plant and the fuel consumption increase, such a check of
losses and recording of results becomes a necessity. In the larger plants, the
saving of but a fraction of one per cent in the fuel bill represents an amount
running into thousands of dollars annually, while the expense of the proper
supervision to secure such saving is small. The methods of supervision
followed in the large plants are necessarily elaborate and complete. In the
smaller plants the same methods may be followed on a more moderate scale
with a corresponding saving in fuel and an inappreciable increase in either
plant organization or expense.
There has been within the last few years a great increase in the practicability
and reliability of the various types of apparatus by which the records of plant
operation may be secured. Much of this apparatus is ingenious and,
considering the work to be done, is remarkably accurate. From the delicate
nature of some of the apparatus, the liability to error necessitates frequent
calibration but even where the accuracy is known [Pg 292]
[Pg 293] to be only within limits of, say, 5 per cent either way, the records
obtained are of the greatest service in considering relative results. Some of
the records desirable and the apparatus for securing them are given below.
different conditions that may arise. What the plant is doing should be made a
matter of continuous record so arranged that the results may be directly
compared for any period or set of conditions, and where such results vary
from the standard set, steps must be taken immediately to remedy the causes
of such failings. Such a record is an important check in the losses in the
plant.
As the size of the plant and the fuel consumption increase, such a check of
losses and recording of results becomes a necessity. In the larger plants, the
saving of but a fraction of one per cent in the fuel bill represents an amount
running into thousands of dollars annually, while the expense of the proper
supervision to secure such saving is small. The methods of supervision
followed in the large plants are necessarily elaborate and complete. In the
smaller plants the same methods may be followed on a more moderate scale
with a corresponding saving in fuel and an inappreciable increase in either
plant organization or expense.
There has been within the last few years a great increase in the practicability
and reliability of the various types of apparatus by which the records of plant
operation may be secured. Much of this apparatus is ingenious and,
considering the work to be done, is remarkably accurate. From the delicate
nature of some of the apparatus, the liability to error necessitates frequent
calibration but even where the accuracy is known [Pg 292]
[Pg 293] to be only within limits of, say, 5 per cent either way, the records
obtained are of the greatest service in considering relative results. Some of
the records desirable and the apparatus for securing them are given below.
Page 400
2400 Horse-power Installation of Cross Drum Babcock & Wilcox
Boilers and Superheaters at the Westinghouse Electric and
Manufacturing Co., East Pittsburgh, Pa.
Inasmuch as the ultimate measure of the efficiency of the boiler plant is the
cost of steam generation, the important records are those of steam generated
and fuel consumed Records of temperature, analyses, draft and the like,
serve as a check on this consumption, indicating the distribution of the losses
and affording a means of remedying conditions where improvement is
possible.
Coal Records—There are many devices on the market for conveniently
weighing the coal used. These are ordinarily accurate within close limits,
and where the size or nature of the plant warrants the investment in such a
device, its use is to be recommended. The coal consumption should be
recorded by some other method than from the weights of coal purchased.
The total weight gives no way of dividing the consumption into periods and
it will unquestionably be found to be profitable to put into operation some
scheme by which the coal is weighed as it is used. In this way, the coal
consumption, during any specific period of the plant’s operation, can be
Boilers and Superheaters at the Westinghouse Electric and
Manufacturing Co., East Pittsburgh, Pa.
Inasmuch as the ultimate measure of the efficiency of the boiler plant is the
cost of steam generation, the important records are those of steam generated
and fuel consumed Records of temperature, analyses, draft and the like,
serve as a check on this consumption, indicating the distribution of the losses
and affording a means of remedying conditions where improvement is
possible.
Coal Records—There are many devices on the market for conveniently
weighing the coal used. These are ordinarily accurate within close limits,
and where the size or nature of the plant warrants the investment in such a
device, its use is to be recommended. The coal consumption should be
recorded by some other method than from the weights of coal purchased.
The total weight gives no way of dividing the consumption into periods and
it will unquestionably be found to be profitable to put into operation some
scheme by which the coal is weighed as it is used. In this way, the coal
consumption, during any specific period of the plant’s operation, can be
Page 401
readily seen. The simplest of such methods which may be used in small
plants is the actual weighing on scales of the fuel as it is brought into the fire
room and the recording of such weights.
Aside from the actual weight of the fuel used, it is often advisable to keep
other coal records, coal and ash analyses and the like, for the evaporation to
be expected will be dependent upon the grade of fuel used and its calorific
value, fusibility of its ash, and like factors.
The highest calorific value for unit cost is not necessarily the indication of
the best commercial results. The cost of fuel is governed by this calorific
value only when such value is modified by local conditions of capacity,
labor and commercial efficiency. One of the important factors entering into
fuel cost is the consideration of the cost of ash handling and the maintenance
of ash handling apparatus if such be installed. The value of a fuel, regardless
of its calorific value, is to be based only on the results obtained in every-day
plant operation.
Coal and ash analyses used in connection with the amount of fuel consumed,
are a direct indication of the relation between the results being secured and
the standard of results which has been set for the plant. The methods of such
analyses have already been described. The apparatus is simple and the
degree of scientific knowledge necessary is only such as may be readily
mastered by plant operatives.
The ash content of a fuel, as indicated from a coal analysis checked against
ash weights as actually found in plant operation, acts as a check on grate
efficiency. The effect of any saving in the ashes, that is, the permissible ash
to be allowed in the fuel purchased, is determined by the point at which the
cost of handling, combined with the falling off in the evaporation, exceeds
the saving of fuel cost through the use of poorer coal.
Water Records—Water records with the coal consumption, form the basis
for judging the economic production of steam. The methods of securing such
records are of later introduction than for coal, but great advances have been
made in the apparatus to be used. Here possibly, to a greater extent than in
any recording device, are the records of value in determining relative
plants is the actual weighing on scales of the fuel as it is brought into the fire
room and the recording of such weights.
Aside from the actual weight of the fuel used, it is often advisable to keep
other coal records, coal and ash analyses and the like, for the evaporation to
be expected will be dependent upon the grade of fuel used and its calorific
value, fusibility of its ash, and like factors.
The highest calorific value for unit cost is not necessarily the indication of
the best commercial results. The cost of fuel is governed by this calorific
value only when such value is modified by local conditions of capacity,
labor and commercial efficiency. One of the important factors entering into
fuel cost is the consideration of the cost of ash handling and the maintenance
of ash handling apparatus if such be installed. The value of a fuel, regardless
of its calorific value, is to be based only on the results obtained in every-day
plant operation.
Coal and ash analyses used in connection with the amount of fuel consumed,
are a direct indication of the relation between the results being secured and
the standard of results which has been set for the plant. The methods of such
analyses have already been described. The apparatus is simple and the
degree of scientific knowledge necessary is only such as may be readily
mastered by plant operatives.
The ash content of a fuel, as indicated from a coal analysis checked against
ash weights as actually found in plant operation, acts as a check on grate
efficiency. The effect of any saving in the ashes, that is, the permissible ash
to be allowed in the fuel purchased, is determined by the point at which the
cost of handling, combined with the falling off in the evaporation, exceeds
the saving of fuel cost through the use of poorer coal.
Water Records—Water records with the coal consumption, form the basis
for judging the economic production of steam. The methods of securing such
records are of later introduction than for coal, but great advances have been
made in the apparatus to be used. Here possibly, to a greater extent than in
any recording device, are the records of value in determining relative
Page 402
evaporation, that is, an error is rather allowable provided such an error be
reasonably constant.
[Pg 294]
The apparatus for recording such evaporation is of two general classes:
Those measuring water before it is fed to the boiler and those measuring the
steam as it leaves. Of the first, the venturi meter is perhaps the best known,
though recently there has come into considerable vogue an apparatus
utilizing a weir notch for the measuring of such water. Both methods are
reasonably accurate and apparatus of this description has an advantage over
one measuring steam in that it may be calibrated much more readily. Of the
steam measuring devices, the one in most common use is the steam flow
meter. Provided the instruments are selected for a proper flow, etc., they are
of inestimable value in indicating the steam consumption. Where such
instruments are placed on the various engine room lines, they will
immediately indicate an excessive consumption for any one of the units.
With a steam flow meter placed on each boiler, it is possible to fix relatively
the amount produced by each boiler and, considered in connection with
some of the “check” records described below, clearly indicate whether its
portion of the total steam produced is up to the standard set for the over-all
boiler room efficiency.
Flue Gas Analysis—The value of a flue gas analysis as a measure of furnace
efficiency has already been indicated. There are on the market a number of
instruments by which a continuous record of the carbon dioxide in the flue
gases may be secured and in general the results so recorded are accurate. The
limitations of an analysis showing only CO2 and the necessity of completing
such an analysis with an Orsat, or like apparatus, and in this way checking
the automatic device, have already been pointed out, but where such records
are properly checked from time to time and are used in conjunction with a
record of flue temperatures, the losses due to excess air or incomplete
combustion and the like may be directly compared for any period. Such
records act as a means for controlling excess air and also as a check on
individual firemen.
Where the size of a plant will not warrant the purchase of an expensive
continuous CO2 recorder, it is advisable to make analyses of samples for
reasonably constant.
[Pg 294]
The apparatus for recording such evaporation is of two general classes:
Those measuring water before it is fed to the boiler and those measuring the
steam as it leaves. Of the first, the venturi meter is perhaps the best known,
though recently there has come into considerable vogue an apparatus
utilizing a weir notch for the measuring of such water. Both methods are
reasonably accurate and apparatus of this description has an advantage over
one measuring steam in that it may be calibrated much more readily. Of the
steam measuring devices, the one in most common use is the steam flow
meter. Provided the instruments are selected for a proper flow, etc., they are
of inestimable value in indicating the steam consumption. Where such
instruments are placed on the various engine room lines, they will
immediately indicate an excessive consumption for any one of the units.
With a steam flow meter placed on each boiler, it is possible to fix relatively
the amount produced by each boiler and, considered in connection with
some of the “check” records described below, clearly indicate whether its
portion of the total steam produced is up to the standard set for the over-all
boiler room efficiency.
Flue Gas Analysis—The value of a flue gas analysis as a measure of furnace
efficiency has already been indicated. There are on the market a number of
instruments by which a continuous record of the carbon dioxide in the flue
gases may be secured and in general the results so recorded are accurate. The
limitations of an analysis showing only CO2 and the necessity of completing
such an analysis with an Orsat, or like apparatus, and in this way checking
the automatic device, have already been pointed out, but where such records
are properly checked from time to time and are used in conjunction with a
record of flue temperatures, the losses due to excess air or incomplete
combustion and the like may be directly compared for any period. Such
records act as a means for controlling excess air and also as a check on
individual firemen.
Where the size of a plant will not warrant the purchase of an expensive
continuous CO2 recorder, it is advisable to make analyses of samples for
Page 403
various conditions of firing and to install an apparatus whereby a sample of
flue gas covering a period of, say, eight hours, may be obtained and such a
sample afterwards analyzed.
Temperature Records—Flue gas temperatures, feed water temperatures and
steam temperatures are all taken with recording thermometers, any number
of which will, when properly calibrated, give accurate results.
A record of flue temperatures is serviceable in checking stack losses and, in
general, the cleanliness of the boiler. A record of steam temperatures, where
superheaters are used, will indicate excessive fluctuations and lead to an
investigation of their cause. Feed temperatures are valuable in showing that
the full benefit of the exhaust steam is being derived.
Draft Regulation—As the capacity of a boiler varies with the combustion
rate and this rate with the draft, an automatic apparatus satisfactorily varying
this draft with the capacity demands on the boiler will obviously be
advantageous.
As has been pointed out, any fuel has some rate of combustion at which the
best results will be obtained. In a properly designed plant where the load is
reasonably steady, the draft necessary to secure such a rate may be regulated
automatically.
Automatic apparatus for the regulation of draft has recently reached a stage
of perfection which in the larger plants at any rate makes its installation
advisable. The [Pg 295] installation of a draft gauge or gauges is strongly to be
recommended and a record of such drafts should be kept as being a check on
the combustion rates.
An important feature to be considered in the installing of all recording
apparatus is its location. Thermometers, draft gauges and flue gas sampling
pipes should be so located as to give as nearly as possible an average of the
conditions, the gases flowing freely over the ends of the thermometers,
couples and sampling pipes. With the location permanent, there is no
security that the samples may be considered an average but in any event
comparative results will be secured which will be useful in plant operation.
flue gas covering a period of, say, eight hours, may be obtained and such a
sample afterwards analyzed.
Temperature Records—Flue gas temperatures, feed water temperatures and
steam temperatures are all taken with recording thermometers, any number
of which will, when properly calibrated, give accurate results.
A record of flue temperatures is serviceable in checking stack losses and, in
general, the cleanliness of the boiler. A record of steam temperatures, where
superheaters are used, will indicate excessive fluctuations and lead to an
investigation of their cause. Feed temperatures are valuable in showing that
the full benefit of the exhaust steam is being derived.
Draft Regulation—As the capacity of a boiler varies with the combustion
rate and this rate with the draft, an automatic apparatus satisfactorily varying
this draft with the capacity demands on the boiler will obviously be
advantageous.
As has been pointed out, any fuel has some rate of combustion at which the
best results will be obtained. In a properly designed plant where the load is
reasonably steady, the draft necessary to secure such a rate may be regulated
automatically.
Automatic apparatus for the regulation of draft has recently reached a stage
of perfection which in the larger plants at any rate makes its installation
advisable. The [Pg 295] installation of a draft gauge or gauges is strongly to be
recommended and a record of such drafts should be kept as being a check on
the combustion rates.
An important feature to be considered in the installing of all recording
apparatus is its location. Thermometers, draft gauges and flue gas sampling
pipes should be so located as to give as nearly as possible an average of the
conditions, the gases flowing freely over the ends of the thermometers,
couples and sampling pipes. With the location permanent, there is no
security that the samples may be considered an average but in any event
comparative results will be secured which will be useful in plant operation.
Page 404
The best permanent location of apparatus will vary considerably with the
design of the boiler.
It may not be out of place to refer briefly to some of the shortcomings found
in boiler room practice, with a suggestion as to a means of overcoming them.
1st. It is sometimes found that the operating force is not fully acquainted
with the boilers and apparatus. Probably the most general of such
shortcomings is the fixed idea in the heads of the operatives that boilers run
above their rated capacity are operating under a state of strain and that by
operating at less than their rated capacity the most economical service is
assured, whereas, by determining what a boiler will do, it may be found that
the most economical rating under the conditions of the plant will be
considerably in excess of the builder’s rating. Such ideas can be dislodged
only by demonstrating to the operatives what maximum load the boilers can
carry, showing how the economy will vary with the load and the determining
of the economical load for the individual plant in question.
2nd. Stokers. With stoker-fired boilers, it is essential that the operators know
the limitations of their stokers as determined by their individual installation.
A thorough understanding of the requirements of efficient handling must be
insisted upon. The operatives must realize that smokeless stacks are not
necessarily the indication of good combustion for, as has been pointed out,
absolute smokelessness is oftentimes secured at an enormous loss in
efficiency through excess air.
Another feature in stoker-fired plants is in the cleaning of fires. It must be
impressed upon the operatives that before the fires are cleaned they should
be put into condition for such cleaning. If this cleaning is done at a definite
time, regardless of whether the fires are in the best condition for cleaning,
there will be a great loss of good fuel with the ashes.
3rd. It is necessary that in each individual plant there be a basis on which to
judge the cleanliness of a boiler. From the operative’s standpoint, it is
probably more necessary that there be a thorough understanding of the
relation between scale and tube difficulties than between scale and
efficiency. It is, of course, impossible to keep boilers absolutely free from
scale at all times, but experience in each individual plant determines the
design of the boiler.
It may not be out of place to refer briefly to some of the shortcomings found
in boiler room practice, with a suggestion as to a means of overcoming them.
1st. It is sometimes found that the operating force is not fully acquainted
with the boilers and apparatus. Probably the most general of such
shortcomings is the fixed idea in the heads of the operatives that boilers run
above their rated capacity are operating under a state of strain and that by
operating at less than their rated capacity the most economical service is
assured, whereas, by determining what a boiler will do, it may be found that
the most economical rating under the conditions of the plant will be
considerably in excess of the builder’s rating. Such ideas can be dislodged
only by demonstrating to the operatives what maximum load the boilers can
carry, showing how the economy will vary with the load and the determining
of the economical load for the individual plant in question.
2nd. Stokers. With stoker-fired boilers, it is essential that the operators know
the limitations of their stokers as determined by their individual installation.
A thorough understanding of the requirements of efficient handling must be
insisted upon. The operatives must realize that smokeless stacks are not
necessarily the indication of good combustion for, as has been pointed out,
absolute smokelessness is oftentimes secured at an enormous loss in
efficiency through excess air.
Another feature in stoker-fired plants is in the cleaning of fires. It must be
impressed upon the operatives that before the fires are cleaned they should
be put into condition for such cleaning. If this cleaning is done at a definite
time, regardless of whether the fires are in the best condition for cleaning,
there will be a great loss of good fuel with the ashes.
3rd. It is necessary that in each individual plant there be a basis on which to
judge the cleanliness of a boiler. From the operative’s standpoint, it is
probably more necessary that there be a thorough understanding of the
relation between scale and tube difficulties than between scale and
efficiency. It is, of course, impossible to keep boilers absolutely free from
scale at all times, but experience in each individual plant determines the
Page 405
limit to which scale can be allowed to form before tube difficulties will
begin or a perceptible falling off in efficiency will take place. With such a
limit of scale formation fixed, the operatives should be impressed with the
danger of allowing it to be exceeded.
4th. The operatives should be instructed as to the losses resulting from
excess air due to leaks in the setting and as to losses in efficiency and
capacity due to the by-passing of gases through the setting, that is, not
following the path of the baffles as originally installed. In replacing tubes
and in cleaning the heating surfaces, care must be taken not to dislodge
baffle brick or tile.
[Pg 296]
2000 Horse-power Installation of Babcock & Wilcox Boilers, Equipped
with Babcock & Wilcox Chain Grate Stokers at the Sunnyside Plant of
the Pennsylvania Tunnel and Terminal Railroad Co., Long Island City,
N. Y.
[Pg 297]
begin or a perceptible falling off in efficiency will take place. With such a
limit of scale formation fixed, the operatives should be impressed with the
danger of allowing it to be exceeded.
4th. The operatives should be instructed as to the losses resulting from
excess air due to leaks in the setting and as to losses in efficiency and
capacity due to the by-passing of gases through the setting, that is, not
following the path of the baffles as originally installed. In replacing tubes
and in cleaning the heating surfaces, care must be taken not to dislodge
baffle brick or tile.
[Pg 296]
2000 Horse-power Installation of Babcock & Wilcox Boilers, Equipped
with Babcock & Wilcox Chain Grate Stokers at the Sunnyside Plant of
the Pennsylvania Tunnel and Terminal Railroad Co., Long Island City,
N. Y.
[Pg 297]
Page 406
5th. That an increase in the temperature of the feed reduces the amount of
work demanded from the boiler has been shown. The necessity of keeping
the feed temperature as high as the quantity of exhaust steam will allow
should be thoroughly understood. As an example of this, there was a case
brought to our attention where a large amount of exhaust steam was wasted
simply because the feed pump showed a tendency to leak if the temperature
of feed water was increased above 140 degrees. The amount wasted was
sufficient to increase the temperature to 180 degrees but was not utilized
simply because of the slight expense necessary to overhaul the feed pump.
The highest return will be obtained when the speed of the feed pumps is
maintained reasonably constant for should the pumps run very slowly at
times, there may be a loss of the steam from other auxiliaries by blowing off
from the heaters.
6th. With a view to checking steam losses through the useless blowing of
safety valves, the operative should be made to realize the great amount of
steam that it is possible to get through a pipe of a given size. Oftentimes the
fireman feels a sense of security from objections to a drop in steam simply
because of the blowing of safety valves, not considering the losses due to
such a cause and makes no effort to check this flow either by manipulation
of dampers or regulation of fires.
The few of the numerous shortcomings outlined above, which may be found
in many plants, are almost entirely due to lack of knowledge on the part of
the operating crew as to the conditions existing in their own plants and the
better performances being secured in others. Such shortcomings can be
overcome only by the education of the operatives, the showing of the defects
of present methods, and instruction in better methods. Where such
instruction is necessary, the value of records is obvious. There is fortunately
a tendency toward the employment of a better class of labor in the boiler
room, a tendency which is becoming more and more marked as the
realization of the possible saving in this end of the plant increases.
The second aspect of boiler room management, dealing with specific
recommendations as to the care and operation of the boilers, is dictated
largely by the nature of the apparatus. Some of the features to be watched in
considering this aspect follow.
work demanded from the boiler has been shown. The necessity of keeping
the feed temperature as high as the quantity of exhaust steam will allow
should be thoroughly understood. As an example of this, there was a case
brought to our attention where a large amount of exhaust steam was wasted
simply because the feed pump showed a tendency to leak if the temperature
of feed water was increased above 140 degrees. The amount wasted was
sufficient to increase the temperature to 180 degrees but was not utilized
simply because of the slight expense necessary to overhaul the feed pump.
The highest return will be obtained when the speed of the feed pumps is
maintained reasonably constant for should the pumps run very slowly at
times, there may be a loss of the steam from other auxiliaries by blowing off
from the heaters.
6th. With a view to checking steam losses through the useless blowing of
safety valves, the operative should be made to realize the great amount of
steam that it is possible to get through a pipe of a given size. Oftentimes the
fireman feels a sense of security from objections to a drop in steam simply
because of the blowing of safety valves, not considering the losses due to
such a cause and makes no effort to check this flow either by manipulation
of dampers or regulation of fires.
The few of the numerous shortcomings outlined above, which may be found
in many plants, are almost entirely due to lack of knowledge on the part of
the operating crew as to the conditions existing in their own plants and the
better performances being secured in others. Such shortcomings can be
overcome only by the education of the operatives, the showing of the defects
of present methods, and instruction in better methods. Where such
instruction is necessary, the value of records is obvious. There is fortunately
a tendency toward the employment of a better class of labor in the boiler
room, a tendency which is becoming more and more marked as the
realization of the possible saving in this end of the plant increases.
The second aspect of boiler room management, dealing with specific
recommendations as to the care and operation of the boilers, is dictated
largely by the nature of the apparatus. Some of the features to be watched in
considering this aspect follow.
Page 407
Before placing a new boiler in service, a careful and thorough examination
should be made of the pressure parts and the setting. The boiler as erected
should correspond in its baffle openings, where baffles are adjustable, with
the prints furnished for its erection, and such baffles should be tight. The
setting should be so constructed that the boiler is free to expand without
interfering with the brickwork. This ability to expand applies also to blow-
off and other piping. After erection all mortar and chips of brick should be
cleaned from the pressure parts. The tie rods should be set up snug and then
slacked slightly until the setting has become thoroughly warm after the first
firing. The boiler should be examined internally before starting to insure the
absence of dirt, any foreign material such as waste, and tools. Oil and paint
are sometimes found in the interior of a new boiler and where such is the
case, a quantity of soda ash should be placed within it, the boiler filled with
water to its normal level and a slow fire started. After twelve hours of slow
simmering, the fire should be allowed to die out, the boiler cooled slowly
and then opened and washed out thoroughly. Such a proceeding will remove
all oil and grease from the interior and prevent the possibility of foaming and
tube difficulties when the boiler is placed in service.
[Pg 298]
The water column piping should be examined and known to be free and
clear. The water level, as indicated by the gauge glass, should be checked by
opening the gauge cocks.
The method of drying out a brick setting before placing a boiler in operation
is described later in the discussion of boiler settings.
A boiler should not be cut into the line with other boilers until the pressure
within it is approximately that in the steam main. The boiler stop valve
should be opened very slowly until it is fully opened. The arrangement of
piping should be such that there can be no possibility of water collecting in a
pocket between the boiler and the main, from which it can be carried over
into the steam line when a boiler is cut in.
In regular operation the safety valve and steam gauge should be checked
daily. In small plants the steam pressure should be raised sufficiently to
cause the safety valves to blow, at which time the steam gauge should
should be made of the pressure parts and the setting. The boiler as erected
should correspond in its baffle openings, where baffles are adjustable, with
the prints furnished for its erection, and such baffles should be tight. The
setting should be so constructed that the boiler is free to expand without
interfering with the brickwork. This ability to expand applies also to blow-
off and other piping. After erection all mortar and chips of brick should be
cleaned from the pressure parts. The tie rods should be set up snug and then
slacked slightly until the setting has become thoroughly warm after the first
firing. The boiler should be examined internally before starting to insure the
absence of dirt, any foreign material such as waste, and tools. Oil and paint
are sometimes found in the interior of a new boiler and where such is the
case, a quantity of soda ash should be placed within it, the boiler filled with
water to its normal level and a slow fire started. After twelve hours of slow
simmering, the fire should be allowed to die out, the boiler cooled slowly
and then opened and washed out thoroughly. Such a proceeding will remove
all oil and grease from the interior and prevent the possibility of foaming and
tube difficulties when the boiler is placed in service.
[Pg 298]
The water column piping should be examined and known to be free and
clear. The water level, as indicated by the gauge glass, should be checked by
opening the gauge cocks.
The method of drying out a brick setting before placing a boiler in operation
is described later in the discussion of boiler settings.
A boiler should not be cut into the line with other boilers until the pressure
within it is approximately that in the steam main. The boiler stop valve
should be opened very slowly until it is fully opened. The arrangement of
piping should be such that there can be no possibility of water collecting in a
pocket between the boiler and the main, from which it can be carried over
into the steam line when a boiler is cut in.
In regular operation the safety valve and steam gauge should be checked
daily. In small plants the steam pressure should be raised sufficiently to
cause the safety valves to blow, at which time the steam gauge should
Page 408
indicate the pressure at which the valve is known to be set. If it does not, one
is in error and the gauge should be compared with one of known accuracy
and any error at once rectified.
In large plants such a method of checking would result in losses too great to
be allowed. Here the gauges and valves are ordinarily checked at the time a
boiler is cut out, the valves being assured of not sticking by daily
instantaneous opening through manipulation by hand of the valve lever. The
daily blowing of the safety valve acts not only as a check on the gauge but
insures the valve against sticking.
The water column should be blown down thoroughly at least once on every
shift and the height of water indicated by the glass checked by the gauge
cocks. The bottom blow-offs should be kept tight. These should be opened at
least once daily to blow from the mud drum any sediment that may have
collected and to reduce the concentration. The amount of blowing down and
the frequency is, of course, determined by the nature of the feed water used.
In case of low water, resulting either from carelessness or from some
unforeseen condition of operation, the essential object to be obtained is the
extinguishing of the fire in the quickest possible manner. Where practicable,
this is best accomplished by the playing of a heavy stream of water from a
hose on the fire. Another method, perhaps not so efficient, but more
generally recommended, is the covering of the fire with wet ashes or fresh
fuel. A boiler so treated should be cut out of line after such an occurrence
and a thorough inspection made to ascertain what damage, if any, has been
done before it is again placed in service.
The efficiency and capacity depend to an extent very much greater than is
ordinarily realized upon the cleanliness of the heating surfaces, both
externally and internally, and too much stress cannot be put upon the
necessity for systematic cleaning as a regular feature in the plant operation.
The outer surfaces of the tubes should be blown free from soot at regular
intervals, the frequency of such cleaning periods being dependent upon the
class of fuel used. The most efficient way of blowing soot from the tubes is
by means of a steam lance with which all parts of the surfaces are reached
and swept clean. There are numerous soot blowing devices on the market
is in error and the gauge should be compared with one of known accuracy
and any error at once rectified.
In large plants such a method of checking would result in losses too great to
be allowed. Here the gauges and valves are ordinarily checked at the time a
boiler is cut out, the valves being assured of not sticking by daily
instantaneous opening through manipulation by hand of the valve lever. The
daily blowing of the safety valve acts not only as a check on the gauge but
insures the valve against sticking.
The water column should be blown down thoroughly at least once on every
shift and the height of water indicated by the glass checked by the gauge
cocks. The bottom blow-offs should be kept tight. These should be opened at
least once daily to blow from the mud drum any sediment that may have
collected and to reduce the concentration. The amount of blowing down and
the frequency is, of course, determined by the nature of the feed water used.
In case of low water, resulting either from carelessness or from some
unforeseen condition of operation, the essential object to be obtained is the
extinguishing of the fire in the quickest possible manner. Where practicable,
this is best accomplished by the playing of a heavy stream of water from a
hose on the fire. Another method, perhaps not so efficient, but more
generally recommended, is the covering of the fire with wet ashes or fresh
fuel. A boiler so treated should be cut out of line after such an occurrence
and a thorough inspection made to ascertain what damage, if any, has been
done before it is again placed in service.
The efficiency and capacity depend to an extent very much greater than is
ordinarily realized upon the cleanliness of the heating surfaces, both
externally and internally, and too much stress cannot be put upon the
necessity for systematic cleaning as a regular feature in the plant operation.
The outer surfaces of the tubes should be blown free from soot at regular
intervals, the frequency of such cleaning periods being dependent upon the
class of fuel used. The most efficient way of blowing soot from the tubes is
by means of a steam lance with which all parts of the surfaces are reached
and swept clean. There are numerous soot blowing devices on the market
Page 409
which are designed to be permanently fixed within the boiler setting. Where
such devices are installed, there are certain features that must be watched to
avoid trouble. If there is any leakage of water of condensation within the
setting coming into contact with the boiler tubes, it will tend toward [Pg 299]
corrosion, or if in contact with the heated brickwork will cause rapid
disintegration of the setting. If the steam jets are so placed that they impinge
directly against the tubes, erosion may take place. Where such permanent
soot blowers are installed, too much care cannot be taken to guard against
these possibilities.
Internally, the tubes must be kept free from scale, the ingredients of which a
study of the chapter on the impurities of water indicates are present in
varying quantities in all feed waters. Not only has the presence of scale a
direct bearing on the efficiency and capacity to be obtained from a boiler but
its absence is an assurance against the burning out of tubes.
In the absence of a blow-pipe action of the flames, it is impossible to burn a
metal surface where water is in intimate contact with that surface.
In stoker-fired plants where a blast is used, and the furnace is not properly
designed, there is a danger of a blow-pipe action if the fires are allowed to
get too thin. The rapid formation of steam at such points of localized heat
may lead to the burning of the metal of the tubes.
Any formation of scale on the interior surface of a boiler keeps the water
from such a surface and increases its tendency to burn. Particles of loose
scale that may become detached will lodge at certain points in the tubes and
localize this tendency at such points. It is because of the danger of detaching
scale and causing loose flakes to be present that the use of a boiler
compound is not recommended for the removal of scale that has already
formed in a boiler. This question is covered in the treatment of feed waters.
If oil is allowed to enter a boiler, its action is the same as that of scale in
keeping the water away from the metal surfaces.
such devices are installed, there are certain features that must be watched to
avoid trouble. If there is any leakage of water of condensation within the
setting coming into contact with the boiler tubes, it will tend toward [Pg 299]
corrosion, or if in contact with the heated brickwork will cause rapid
disintegration of the setting. If the steam jets are so placed that they impinge
directly against the tubes, erosion may take place. Where such permanent
soot blowers are installed, too much care cannot be taken to guard against
these possibilities.
Internally, the tubes must be kept free from scale, the ingredients of which a
study of the chapter on the impurities of water indicates are present in
varying quantities in all feed waters. Not only has the presence of scale a
direct bearing on the efficiency and capacity to be obtained from a boiler but
its absence is an assurance against the burning out of tubes.
In the absence of a blow-pipe action of the flames, it is impossible to burn a
metal surface where water is in intimate contact with that surface.
In stoker-fired plants where a blast is used, and the furnace is not properly
designed, there is a danger of a blow-pipe action if the fires are allowed to
get too thin. The rapid formation of steam at such points of localized heat
may lead to the burning of the metal of the tubes.
Any formation of scale on the interior surface of a boiler keeps the water
from such a surface and increases its tendency to burn. Particles of loose
scale that may become detached will lodge at certain points in the tubes and
localize this tendency at such points. It is because of the danger of detaching
scale and causing loose flakes to be present that the use of a boiler
compound is not recommended for the removal of scale that has already
formed in a boiler. This question is covered in the treatment of feed waters.
If oil is allowed to enter a boiler, its action is the same as that of scale in
keeping the water away from the metal surfaces.
Page 410
Fig. 41
It has been proven beyond a doubt that a very large percentage of tube losses
is due directly to the presence of scale which, in many instances, has been so
thin as to be considered of no moment, and the importance of maintaining
the boiler heating surfaces in a clean condition cannot be emphasized too
strongly.
[Pg 300]
The internal cleaning can best be accomplished by means of an air or water-
driven turbine, the cutter heads of which may be changed to handle various
thicknesses of scale. Fig. 41 shows a turbine cleaner with various cutting
heads, which has been found to give satisfactory service.
Where a water-driven turbine is used, it should be connected to a pump
which will deliver at least 120 gallons per minute per cleaner at 150 pounds
pressure. This pressure should never be less than 90 pounds if satisfactory
results are desired. Where an air-driven turbine is used, the pressure should
be at least 100 pounds, though 150 pounds is preferable, and sufficient water
should be introduced into the tube to keep the cutting head cool and assist in
washing down the scale as it is chipped off.
Where scale has been allowed to accumulate to an excessive thickness, the
work of removal is difficult and tedious. Where such a heavy scale is of
It has been proven beyond a doubt that a very large percentage of tube losses
is due directly to the presence of scale which, in many instances, has been so
thin as to be considered of no moment, and the importance of maintaining
the boiler heating surfaces in a clean condition cannot be emphasized too
strongly.
[Pg 300]
The internal cleaning can best be accomplished by means of an air or water-
driven turbine, the cutter heads of which may be changed to handle various
thicknesses of scale. Fig. 41 shows a turbine cleaner with various cutting
heads, which has been found to give satisfactory service.
Where a water-driven turbine is used, it should be connected to a pump
which will deliver at least 120 gallons per minute per cleaner at 150 pounds
pressure. This pressure should never be less than 90 pounds if satisfactory
results are desired. Where an air-driven turbine is used, the pressure should
be at least 100 pounds, though 150 pounds is preferable, and sufficient water
should be introduced into the tube to keep the cutting head cool and assist in
washing down the scale as it is chipped off.
Where scale has been allowed to accumulate to an excessive thickness, the
work of removal is difficult and tedious. Where such a heavy scale is of
Page 411
sulphate formation, its removal may be assisted by filling the boiler with
water to which there has been added a quantity of soda ash, a bucketful to
each drum, starting a low fire and allowing the water to boil for twenty-four
hours with no pressure on the boiler. It should be cooled slowly, drained, and
the turbine cleaner used immediately, as the scale will tend to harden rapidly
under the action of the air.
Where oil has been allowed to get into a boiler, it should be removed before
placing the boiler in service, as described previously where reference is
made to its removal by boiling out with soda ash.
Where pitting or corrosion is noted, the parts affected should be carefully
cleaned and the interior of the drums should be painted with white zinc if the
boiler is to remain idle. The cause of such action should be immediately
ascertained and steps taken to apply the proper remedy.
When making an internal inspection of a boiler or when cleaning the interior
heating surfaces, great care must be taken to guard against the possibility of
steam entering the boiler in question from other boilers on the same line
either through the careless opening of the boiler stop valve or some auxiliary
valve or from an open blow-off. Bad accidents through scalding have
resulted from the neglect of this precaution.
Boiler brickwork should be kept pointed up and all cracks filled. The boiler
baffles should be kept tight to prevent by-passing of any gases through the
heating surfaces.
Boilers should be taken out of service at regular intervals for cleaning and
repairs. When this is done, the boiler should be cooled slowly, and when
possible, be allowed to stand for twenty-four hours after the fire is drawn
before opening. The cooling process should not be hurried by allowing cold
air to rush through the setting as this will invariably cause trouble with the
brickwork. When a boiler is off for cleaning, a careful examination should
be made of its condition, both external and internal, and all leaks of steam,
water and air through the setting stopped. If water is allowed to come into
contact with brickwork that is heated, rapid disintegration will take place. If
water is allowed to come into contact with the metal of the boiler when out
of service, there is a likelihood of corrosion.
water to which there has been added a quantity of soda ash, a bucketful to
each drum, starting a low fire and allowing the water to boil for twenty-four
hours with no pressure on the boiler. It should be cooled slowly, drained, and
the turbine cleaner used immediately, as the scale will tend to harden rapidly
under the action of the air.
Where oil has been allowed to get into a boiler, it should be removed before
placing the boiler in service, as described previously where reference is
made to its removal by boiling out with soda ash.
Where pitting or corrosion is noted, the parts affected should be carefully
cleaned and the interior of the drums should be painted with white zinc if the
boiler is to remain idle. The cause of such action should be immediately
ascertained and steps taken to apply the proper remedy.
When making an internal inspection of a boiler or when cleaning the interior
heating surfaces, great care must be taken to guard against the possibility of
steam entering the boiler in question from other boilers on the same line
either through the careless opening of the boiler stop valve or some auxiliary
valve or from an open blow-off. Bad accidents through scalding have
resulted from the neglect of this precaution.
Boiler brickwork should be kept pointed up and all cracks filled. The boiler
baffles should be kept tight to prevent by-passing of any gases through the
heating surfaces.
Boilers should be taken out of service at regular intervals for cleaning and
repairs. When this is done, the boiler should be cooled slowly, and when
possible, be allowed to stand for twenty-four hours after the fire is drawn
before opening. The cooling process should not be hurried by allowing cold
air to rush through the setting as this will invariably cause trouble with the
brickwork. When a boiler is off for cleaning, a careful examination should
be made of its condition, both external and internal, and all leaks of steam,
water and air through the setting stopped. If water is allowed to come into
contact with brickwork that is heated, rapid disintegration will take place. If
water is allowed to come into contact with the metal of the boiler when out
of service, there is a likelihood of corrosion.
Page 412
If a boiler is to remain idle for some time, its deterioration may be much
more rapid than when in service. If the period for which it is to be laid off is
not to exceed three months, it may be filled with water while out of service.
The boiler should first be cleaned thoroughly, internally and externally, all
soot and ashes being removed from [Pg 301] the exterior of the pressure parts
and any accumulation of scale removed from the interior surfaces. It should
then be filled with water, to which five or six pails of soda ash have been
added, a slow fire started to drive the air from the boiler, the fire drawn and
the boiler pumped full. In this condition it may be kept for some time
without bad effects.
If the boiler is to be out of service for more than three months, it should be
emptied, drained and thoroughly dried after being cleaned. A tray of quick
lime should be placed in each drum, the boiler closed, the grates covered and
a quantity of quick lime placed on top of the covering. Special care should
be taken to prevent air, steam or water leaks into the boiler or onto the
pressure parts to obviate danger of corrosion.
more rapid than when in service. If the period for which it is to be laid off is
not to exceed three months, it may be filled with water while out of service.
The boiler should first be cleaned thoroughly, internally and externally, all
soot and ashes being removed from [Pg 301] the exterior of the pressure parts
and any accumulation of scale removed from the interior surfaces. It should
then be filled with water, to which five or six pails of soda ash have been
added, a slow fire started to drive the air from the boiler, the fire drawn and
the boiler pumped full. In this condition it may be kept for some time
without bad effects.
If the boiler is to be out of service for more than three months, it should be
emptied, drained and thoroughly dried after being cleaned. A tray of quick
lime should be placed in each drum, the boiler closed, the grates covered and
a quantity of quick lime placed on top of the covering. Special care should
be taken to prevent air, steam or water leaks into the boiler or onto the
pressure parts to obviate danger of corrosion.
Page 413
3000 Horse-power Installation of Babcock & Wilcox Boilers in the Main
Power Plant, Chicago & Northwestern Ry. Depot, Chicago, Ill.
Power Plant, Chicago & Northwestern Ry. Depot, Chicago, Ill.
Page 414
[Pg 302]
Page 415
BRICKWORK BOILER SETTINGS
A consideration of the losses in boiler efficiency, due to the effects of excess
air, clearly indicates the necessity of maintaining the brick setting of a boiler
tight and free from air leaks. In view of the temperatures to which certain
portions of such a setting are subjected, the material to be used in its
construction must be of the best procurable.
Boiler settings to-day consist almost universally of brickwork—two kinds
being used, namely, red brick and fire brick.
The red brick should only be used in such portions of the setting as are well
protected from the heat. In such location, their service is not so severe as that
of fire brick and ordinarily, if such red brick are sound, hard, well burned
and uniform, they will serve their purpose.
The fire brick should be selected with the greatest care, as it is this portion of
the setting that has to endure the high temperatures now developed in boiler
practice. To a great extent, the life of a boiler setting is dependent upon the
quality of the fire brick used and the care exercised in its laying.
The best fire brick are manufactured from the fire clays of Pennsylvania.
South and west from this locality the quality of fire clay becomes poorer as
the distance increases, some of the southern fire clays containing a
considerable percentage of iron oxide.
Until very recently, the important characteristic on which to base a judgment
of the suitability of fire brick for use in connection with boiler settings has
been considered the melting point, or the temperature at which the brick will
liquify and run. Experience has shown, however, that this point is only
important within certain limits and that the real basis on which to judge
material of this description is, from the boiler man’s standpoint, the quality
of plasticity under a given load. This tendency of a brick to become plastic
occurs at a temperature much below the melting point and to a degree that
may cause the brick to become deformed under the stress to which it is
A consideration of the losses in boiler efficiency, due to the effects of excess
air, clearly indicates the necessity of maintaining the brick setting of a boiler
tight and free from air leaks. In view of the temperatures to which certain
portions of such a setting are subjected, the material to be used in its
construction must be of the best procurable.
Boiler settings to-day consist almost universally of brickwork—two kinds
being used, namely, red brick and fire brick.
The red brick should only be used in such portions of the setting as are well
protected from the heat. In such location, their service is not so severe as that
of fire brick and ordinarily, if such red brick are sound, hard, well burned
and uniform, they will serve their purpose.
The fire brick should be selected with the greatest care, as it is this portion of
the setting that has to endure the high temperatures now developed in boiler
practice. To a great extent, the life of a boiler setting is dependent upon the
quality of the fire brick used and the care exercised in its laying.
The best fire brick are manufactured from the fire clays of Pennsylvania.
South and west from this locality the quality of fire clay becomes poorer as
the distance increases, some of the southern fire clays containing a
considerable percentage of iron oxide.
Until very recently, the important characteristic on which to base a judgment
of the suitability of fire brick for use in connection with boiler settings has
been considered the melting point, or the temperature at which the brick will
liquify and run. Experience has shown, however, that this point is only
important within certain limits and that the real basis on which to judge
material of this description is, from the boiler man’s standpoint, the quality
of plasticity under a given load. This tendency of a brick to become plastic
occurs at a temperature much below the melting point and to a degree that
may cause the brick to become deformed under the stress to which it is
Page 416
subjected. The allowable plastic or softening temperature will naturally be
relative and dependent upon the stress to be endured.
With the plasticity the determining factor, the perfect fire brick is one whose
critical point of plasticity lies well above the working temperature of the fire.
It is probable that there are but few brick on the market which would not
show, if tested, this critical temperature at the stress met with in arch
construction at a point less than 2400 degrees. The fact that an arch will
stand for a long period under furnace temperatures considerably above this
point is due entirely to the fact that its temperature as a whole is far below
the furnace temperature and only about 10 per cent of its cross section
nearest the fire approaches the furnace temperature. This is borne out by the
fact that arches which are heated on both sides to the full temperature of an
ordinary furnace will first bow down in the middle and eventually fall.
A method of testing brick for this characteristic is given in the Technologic
Paper No. 7 of the Bureau of Standards dealing with “The testing of clay
refractories with special reference to their load carrying capacity at furnace
temperatures.” Referring to the test for this specific characteristic, this
publication recommends the following: “When subjected to the load test in a
manner substantially as described in this bulletin, at 1350 degrees centigrade
(2462 degrees Fahrenheit), and under a load of [Pg 303] 50 pounds per square
inch, a standard fire brick tested on end should show no serious deformation
and should not be compressed more than one inch, referred to the standard
length of nine inches.”
In the Bureau of Standards test for softening temperature, or critical
temperature of plasticity under the specified load, the brick are tested on end.
In testing fire brick for boiler purposes such a method might be criticised,
because such a test is a compression test and subject to errors from unequal
bearing surfaces causing shear. Furthermore, a series of samples, presumably
duplicates, will not fail in the same way, due to the mechanical variation in
the manufacture of the brick. Arches that fail through plasticity show that the
tensile strength of the brick is important, this being evidenced by the fact
that the bottom of a wedge brick in an arch that has failed is usually found to
be wider than the top and the adjacent bricks are firmly cemented together.
relative and dependent upon the stress to be endured.
With the plasticity the determining factor, the perfect fire brick is one whose
critical point of plasticity lies well above the working temperature of the fire.
It is probable that there are but few brick on the market which would not
show, if tested, this critical temperature at the stress met with in arch
construction at a point less than 2400 degrees. The fact that an arch will
stand for a long period under furnace temperatures considerably above this
point is due entirely to the fact that its temperature as a whole is far below
the furnace temperature and only about 10 per cent of its cross section
nearest the fire approaches the furnace temperature. This is borne out by the
fact that arches which are heated on both sides to the full temperature of an
ordinary furnace will first bow down in the middle and eventually fall.
A method of testing brick for this characteristic is given in the Technologic
Paper No. 7 of the Bureau of Standards dealing with “The testing of clay
refractories with special reference to their load carrying capacity at furnace
temperatures.” Referring to the test for this specific characteristic, this
publication recommends the following: “When subjected to the load test in a
manner substantially as described in this bulletin, at 1350 degrees centigrade
(2462 degrees Fahrenheit), and under a load of [Pg 303] 50 pounds per square
inch, a standard fire brick tested on end should show no serious deformation
and should not be compressed more than one inch, referred to the standard
length of nine inches.”
In the Bureau of Standards test for softening temperature, or critical
temperature of plasticity under the specified load, the brick are tested on end.
In testing fire brick for boiler purposes such a method might be criticised,
because such a test is a compression test and subject to errors from unequal
bearing surfaces causing shear. Furthermore, a series of samples, presumably
duplicates, will not fail in the same way, due to the mechanical variation in
the manufacture of the brick. Arches that fail through plasticity show that the
tensile strength of the brick is important, this being evidenced by the fact
that the bottom of a wedge brick in an arch that has failed is usually found to
be wider than the top and the adjacent bricks are firmly cemented together.
Page 417
A better method of testing is that of testing the brick as a beam subjected to
its own weight and not on end. This method has been used for years in
Germany and is recommended by the highest authorities in ceramics. It takes
into account the failure by tension in the brick as well as by compression and
thus covers the tension element which is important in arch construction.
The plastic point under a unit stress of 100 pounds per square inch, which
may be taken as the average maximum arch stress, should be above 2800
degrees to give perfect results and should be above 2400 degrees to enable
the brick to be used with any degree of satisfaction.
The other characteristics by which the quality of a fire brick is to be judged
are:
Fusion point. In view of the fact that the critical temperature of plasticity is
below the fusion point, this is only important as an indication from high
fusion point of a high temperature of plasticity.
Hardness. This is a relative quality based on an arbitrary scale of 10 and is
an indication of probable cracking and spalling.
Expansion. The lineal expansion per brick in inches. This characteristic in
conjunction with hardness is a measure of the physical movement of the
brick as affecting a mass of brickwork, such movement resulting in cracked
walls, etc. The expansion will vary between wide limits in different brick
and provided such expansion is not in excess of, say, .05 inch in a 9-inch
brick, when measured at 2600 degrees, it is not particularly important in a
properly designed furnace, though in general the smaller the expansion the
better.
Compression. The strength necessary to cause crushing of the brick at the
center of the 4½ inch face by a steel block one inch square. The compression
should ordinarily be low, a suggested standard being that a brick show signs
of crushing at 7500 pounds.
Size of Nodules. The average size of flint grains when the brick is carefully
crushed. The scale of these sizes may be considered: Small, size of
anthracite rice; large, size of anthracite pea.
its own weight and not on end. This method has been used for years in
Germany and is recommended by the highest authorities in ceramics. It takes
into account the failure by tension in the brick as well as by compression and
thus covers the tension element which is important in arch construction.
The plastic point under a unit stress of 100 pounds per square inch, which
may be taken as the average maximum arch stress, should be above 2800
degrees to give perfect results and should be above 2400 degrees to enable
the brick to be used with any degree of satisfaction.
The other characteristics by which the quality of a fire brick is to be judged
are:
Fusion point. In view of the fact that the critical temperature of plasticity is
below the fusion point, this is only important as an indication from high
fusion point of a high temperature of plasticity.
Hardness. This is a relative quality based on an arbitrary scale of 10 and is
an indication of probable cracking and spalling.
Expansion. The lineal expansion per brick in inches. This characteristic in
conjunction with hardness is a measure of the physical movement of the
brick as affecting a mass of brickwork, such movement resulting in cracked
walls, etc. The expansion will vary between wide limits in different brick
and provided such expansion is not in excess of, say, .05 inch in a 9-inch
brick, when measured at 2600 degrees, it is not particularly important in a
properly designed furnace, though in general the smaller the expansion the
better.
Compression. The strength necessary to cause crushing of the brick at the
center of the 4½ inch face by a steel block one inch square. The compression
should ordinarily be low, a suggested standard being that a brick show signs
of crushing at 7500 pounds.
Size of Nodules. The average size of flint grains when the brick is carefully
crushed. The scale of these sizes may be considered: Small, size of
anthracite rice; large, size of anthracite pea.
Page 418
Ratio of Nodules. The percentage of a given volume occupied by the flint
grains. This scale may be considered: High, 90 to 100 per cent; medium, 50
to 90 per cent; low, 10 to 50 per cent.
The statement of characteristics suggested as desirable, are for arch purposes
where the hardest service is met. For side wall purposes the compression and
hardness limit may be raised considerably and the plastic point lowered.
[Pg 304]
Aside from the physical properties by which a fire brick is judged, it is
sometimes customary to require a chemical analysis of the brick. Such an
analysis is only necessary as determining the amount of total basic fluxes
(K2O, Na2O, CaO, MgO and FeO). These fluxes are ordinarily combined
into one expression, indicated by the symbol RO. This total becomes
important only above 0.2 molecular equivalent as expressed in ceramic
empirical formulae, and this limit should not be exceeded.[75]
From the nature of fire brick, their value can only be considered from a
relative standpoint. Generally speaking, what are known as first-grade fire
brick may be divided into three classes, suitable for various conditions of
operation, as follows:
Class A. For stoker-fired furnaces where high overloads are to be expected
or where other extreme conditions of service are apt to occur.
Class B. For ordinary stoker settings where there will be no excessive
overloads required from the boiler or any hand-fired furnaces where the rates
of driving will be high for such practice.
Class C. For ordinary hand-fired settings where the presumption is that the
boilers will not be overloaded except at rare intervals and for short periods
only.
Table 61 gives the characteristics of these three classes according to the
features determining the quality. This table indicates that the hardness of the
brick in general increases with the poorer qualities. Provided the hardness is
sufficient to enable the brick to withstand its load, additional hardness is a
detriment rather than an advantage.
grains. This scale may be considered: High, 90 to 100 per cent; medium, 50
to 90 per cent; low, 10 to 50 per cent.
The statement of characteristics suggested as desirable, are for arch purposes
where the hardest service is met. For side wall purposes the compression and
hardness limit may be raised considerably and the plastic point lowered.
[Pg 304]
Aside from the physical properties by which a fire brick is judged, it is
sometimes customary to require a chemical analysis of the brick. Such an
analysis is only necessary as determining the amount of total basic fluxes
(K2O, Na2O, CaO, MgO and FeO). These fluxes are ordinarily combined
into one expression, indicated by the symbol RO. This total becomes
important only above 0.2 molecular equivalent as expressed in ceramic
empirical formulae, and this limit should not be exceeded.[75]
From the nature of fire brick, their value can only be considered from a
relative standpoint. Generally speaking, what are known as first-grade fire
brick may be divided into three classes, suitable for various conditions of
operation, as follows:
Class A. For stoker-fired furnaces where high overloads are to be expected
or where other extreme conditions of service are apt to occur.
Class B. For ordinary stoker settings where there will be no excessive
overloads required from the boiler or any hand-fired furnaces where the rates
of driving will be high for such practice.
Class C. For ordinary hand-fired settings where the presumption is that the
boilers will not be overloaded except at rare intervals and for short periods
only.
Table 61 gives the characteristics of these three classes according to the
features determining the quality. This table indicates that the hardness of the
brick in general increases with the poorer qualities. Provided the hardness is
sufficient to enable the brick to withstand its load, additional hardness is a
detriment rather than an advantage.
Page 419
TABLE 61
APPROXIMATE CLASSIFICATION OF FIRE BRICK
Characteristics Class A Class B Class C
Fuse Point, Degrees Safe at Degrees Safe at Degrees Safe at Degrees
Fahrenheit 3200-3300 2900-3200 2900-3000
Compression Pounds 6500-7500 7500-11,000 8500-15,000
Hardness Relative 1-2 2-4 4-6
Medium to Medium to
Size of Nodules Medium
Medium Large Large
Medium Low to
Ratio of Nodules High Medium to High
Medium
An approximate determination of the quality of a fire brick may be made
from the appearance of a fracture. Where such a fracture is open, clean,
white and flinty, the brick in all probability is of a good quality. If this
fracture has the fine uniform texture of bread, the brick is probably poor.
In considering the heavy duty of brick in boiler furnaces, experience shows
that arches are the only part that ordinarily give trouble. These fail from the
following causes:
Bad workmanship in laying up of brick. This feature is treated below.
The tendency of a brick to become plastic at a temperature below the fusing
point. The limits of allowable plastic temperature have already been pointed
out.
Spalling. This action occurs on the inner ends of combustion arches where
they are swept by gases at a high velocity at the full furnace temperature.
The most troublesome spalling arises through cold air striking the heated
brickwork. Failure [Pg 305] from this cause is becoming rare, due to the large
increase in number of stoker installations in which rapid temperature
changes are to a great degree eliminated. Furthermore, there are a number of
brick on the market practically free from such defects and where a new brick
is considered, it can be tried out and if the defect exists, can be readily
detected and the brick discarded.
APPROXIMATE CLASSIFICATION OF FIRE BRICK
Characteristics Class A Class B Class C
Fuse Point, Degrees Safe at Degrees Safe at Degrees Safe at Degrees
Fahrenheit 3200-3300 2900-3200 2900-3000
Compression Pounds 6500-7500 7500-11,000 8500-15,000
Hardness Relative 1-2 2-4 4-6
Medium to Medium to
Size of Nodules Medium
Medium Large Large
Medium Low to
Ratio of Nodules High Medium to High
Medium
An approximate determination of the quality of a fire brick may be made
from the appearance of a fracture. Where such a fracture is open, clean,
white and flinty, the brick in all probability is of a good quality. If this
fracture has the fine uniform texture of bread, the brick is probably poor.
In considering the heavy duty of brick in boiler furnaces, experience shows
that arches are the only part that ordinarily give trouble. These fail from the
following causes:
Bad workmanship in laying up of brick. This feature is treated below.
The tendency of a brick to become plastic at a temperature below the fusing
point. The limits of allowable plastic temperature have already been pointed
out.
Spalling. This action occurs on the inner ends of combustion arches where
they are swept by gases at a high velocity at the full furnace temperature.
The most troublesome spalling arises through cold air striking the heated
brickwork. Failure [Pg 305] from this cause is becoming rare, due to the large
increase in number of stoker installations in which rapid temperature
changes are to a great degree eliminated. Furthermore, there are a number of
brick on the market practically free from such defects and where a new brick
is considered, it can be tried out and if the defect exists, can be readily
detected and the brick discarded.
Page 420
Failures of arches from the expansive power of brick are also rare, due to the
fact that there are a number of brick in which the expansion is well within
the allowable limits and the ease with which such defects may be determined
before a brick is used.
Failures through chemical disintegration. Failure through this cause is found
only occasionally in brick containing a high percentage of iron oxide.
With the grade of brick selected best suited to the service of the boiler to be
set, the other factor affecting the life of the setting is the laying. It is
probable that more setting difficulties arise from the improper workmanship
in the laying up of brick than from poor material, and to insure a setting
which will remain tight it is necessary that the masonry work be done most
carefully. This is particularly true where the boiler is of such a type as to
require combustion arches in the furnace.
Red brick should be laid in a thoroughly mixed mortar composed of one
volume of Portland cement, 3 volumes of unslacked lime and 16 volumes of
clear sharp sand. Not less than 2½ bushels of lime should be used in the
laying up of 1000 brick. Each brick should be thoroughly embedded and all
joints filled. Where red brick and fire brick are both used in the same wall,
they should be carried up at the same time and thoroughly bonded to each
other.
All fire brick should be dry when used and protected from moisture until
used. Each brick should be dipped in a thin fire clay wash, “rubbed and
shoved” into place, and tapped with a wooden mallet until it touches the
brick next below it. It must be recognized that fire clay is not a cement and
that it has little or no holding power. Its action is that of a filler rather than a
binder and no fire-clay wash should be used which has a consistency
sufficient to permit the use of a trowel.
All fire-brick linings should be laid up four courses of headers and one
stretcher. Furnace center walls should be entirely of fire brick. If the center
of such walls are built of red brick, they will melt down and cause the failure
of the wall as a whole.
fact that there are a number of brick in which the expansion is well within
the allowable limits and the ease with which such defects may be determined
before a brick is used.
Failures through chemical disintegration. Failure through this cause is found
only occasionally in brick containing a high percentage of iron oxide.
With the grade of brick selected best suited to the service of the boiler to be
set, the other factor affecting the life of the setting is the laying. It is
probable that more setting difficulties arise from the improper workmanship
in the laying up of brick than from poor material, and to insure a setting
which will remain tight it is necessary that the masonry work be done most
carefully. This is particularly true where the boiler is of such a type as to
require combustion arches in the furnace.
Red brick should be laid in a thoroughly mixed mortar composed of one
volume of Portland cement, 3 volumes of unslacked lime and 16 volumes of
clear sharp sand. Not less than 2½ bushels of lime should be used in the
laying up of 1000 brick. Each brick should be thoroughly embedded and all
joints filled. Where red brick and fire brick are both used in the same wall,
they should be carried up at the same time and thoroughly bonded to each
other.
All fire brick should be dry when used and protected from moisture until
used. Each brick should be dipped in a thin fire clay wash, “rubbed and
shoved” into place, and tapped with a wooden mallet until it touches the
brick next below it. It must be recognized that fire clay is not a cement and
that it has little or no holding power. Its action is that of a filler rather than a
binder and no fire-clay wash should be used which has a consistency
sufficient to permit the use of a trowel.
All fire-brick linings should be laid up four courses of headers and one
stretcher. Furnace center walls should be entirely of fire brick. If the center
of such walls are built of red brick, they will melt down and cause the failure
of the wall as a whole.
Page 421
Fire-brick arches should be constructed of selected brick which are smooth,
straight and uniform. The frames on which such arches are built, called arch
centers, should be constructed of batten strips not over 2 inches wide. The
brick should be laid on these centers in courses, not in rings, each joint being
broken with a bond equal to the length of half a brick. Each course should be
first tried in place dry, and checked with a straight edge to insure a uniform
thickness of joint between courses. Each brick should be dipped on one side
and two edges only and tapped into place with a mallet. Wedge brick courses
should be used only where necessary to keep the bottom faces of the straight
brick course in even contact with the centers. When such contact cannot be
exactly secured by the use of wedge brick, the straight brick should lean
away from the center of the arch rather than toward it. When the arch is
approximately two-thirds completed, a trial ring should be laid to determine
whether the key course will fit. When some cutting is necessary to secure
such a fit, it should be done on the two adjacent courses on the side of the
brick away from the key. It is necessary that the keying course be a true fit
from top to bottom, and after it has been dipped and driven it should not
extend below the surface of the arch, [Pg 306]
[Pg 307] but preferably should have its lower ledge one-quarter inch above this
surface. After fitting, the keys should be dipped, replaced loosely, and the
whole course driven uniformly into place by means of a heavy hammer and
a piece of wood extending the full length of the keying course. Such a
driving in of this course should raise the arch as a whole from the center. The
center should be so constructed that it may be dropped free of the arch when
the key course is in place and removed from the furnace without being
burned out.
straight and uniform. The frames on which such arches are built, called arch
centers, should be constructed of batten strips not over 2 inches wide. The
brick should be laid on these centers in courses, not in rings, each joint being
broken with a bond equal to the length of half a brick. Each course should be
first tried in place dry, and checked with a straight edge to insure a uniform
thickness of joint between courses. Each brick should be dipped on one side
and two edges only and tapped into place with a mallet. Wedge brick courses
should be used only where necessary to keep the bottom faces of the straight
brick course in even contact with the centers. When such contact cannot be
exactly secured by the use of wedge brick, the straight brick should lean
away from the center of the arch rather than toward it. When the arch is
approximately two-thirds completed, a trial ring should be laid to determine
whether the key course will fit. When some cutting is necessary to secure
such a fit, it should be done on the two adjacent courses on the side of the
brick away from the key. It is necessary that the keying course be a true fit
from top to bottom, and after it has been dipped and driven it should not
extend below the surface of the arch, [Pg 306]
[Pg 307] but preferably should have its lower ledge one-quarter inch above this
surface. After fitting, the keys should be dipped, replaced loosely, and the
whole course driven uniformly into place by means of a heavy hammer and
a piece of wood extending the full length of the keying course. Such a
driving in of this course should raise the arch as a whole from the center. The
center should be so constructed that it may be dropped free of the arch when
the key course is in place and removed from the furnace without being
burned out.
Page 422
A Typical Steel Casing for a Babcock & Wilcox Boiler Built by The
Babcock & Wilcox Co.
Care of Brickwork—Before a boiler is placed in service, it is essential that
the brickwork setting be thoroughly and properly dried, or otherwise the
setting will invariably crack. The best method of starting such a process is to
block open the boiler damper and the ashpit doors as soon as the brickwork
is completed and in this way maintain a free circulation of air through the
setting. If possible, such preliminary drying should be continued for several
days before any fire is placed in the furnace. When ready for the drying out
fire, wood should be used at the start in a light fire which may be gradually
built up as the walls become warm. After the walls have become thoroughly
heated, coal may be fired and the boiler placed in service.
As already stated, the life of a boiler setting is dependent to a large extent
upon the material entering into its construction and the care with which such
material is laid. A third and equally important factor in the determining of
such life is the care given to the maintaining of the setting in good condition
after the boiler is placed in operation. This feature is discussed more fully in
the chapter dealing with general boiler room management.
Babcock & Wilcox Co.
Care of Brickwork—Before a boiler is placed in service, it is essential that
the brickwork setting be thoroughly and properly dried, or otherwise the
setting will invariably crack. The best method of starting such a process is to
block open the boiler damper and the ashpit doors as soon as the brickwork
is completed and in this way maintain a free circulation of air through the
setting. If possible, such preliminary drying should be continued for several
days before any fire is placed in the furnace. When ready for the drying out
fire, wood should be used at the start in a light fire which may be gradually
built up as the walls become warm. After the walls have become thoroughly
heated, coal may be fired and the boiler placed in service.
As already stated, the life of a boiler setting is dependent to a large extent
upon the material entering into its construction and the care with which such
material is laid. A third and equally important factor in the determining of
such life is the care given to the maintaining of the setting in good condition
after the boiler is placed in operation. This feature is discussed more fully in
the chapter dealing with general boiler room management.
Page 423
Steel Casings—In the chapter dealing with the losses operating against high
efficiencies as indicated by the heat balance, it has been shown that a
considerable portion of such losses is due to radiation and to air infiltration
into the boiler setting. These losses have been variously estimated from 2 to
10 per cent, depending upon the condition of the setting and the amount of
radiation surface, the latter in turn being dependent upon the size of the
boiler used. In the modern efforts after the highest obtainable plant
efficiencies much has been done to reduce such losses by the use of an
insulated steel casing covering the brickwork. In an average size boiler unit
the use of such casing, when properly installed, will reduce radiation losses
from one to two per cent., over what can be accomplished with the best brick
setting without such casing and, in addition, prevent the loss due to the
infiltration of air, which may amount to an additional five per cent., as
compared with brick settings that are not maintained in good order. Steel
plate, or steel plate backed by asbestos mill-board, while acting as a
preventative against the infiltration of air through the boiler setting, is not as
effective from the standpoint of decreasing radiation losses as a casing
properly insulated from the brick portion of the setting by magnesia block
and asbestos mill-board. A casing which has been found to give excellent
results in eliminating air leakage and in the reduction of radiation losses is
clearly illustrated on page 306.
Many attempts have been made to use some material other than brick for
boiler settings but up to the present nothing has been found that may be
considered successful or which will give as satisfactory service under severe
conditions as properly laid brickwork.
FOOTNOTES
[75] For methods of determining, see Technologic Paper No. 7, Bureau of
Standards, page 44.
efficiencies as indicated by the heat balance, it has been shown that a
considerable portion of such losses is due to radiation and to air infiltration
into the boiler setting. These losses have been variously estimated from 2 to
10 per cent, depending upon the condition of the setting and the amount of
radiation surface, the latter in turn being dependent upon the size of the
boiler used. In the modern efforts after the highest obtainable plant
efficiencies much has been done to reduce such losses by the use of an
insulated steel casing covering the brickwork. In an average size boiler unit
the use of such casing, when properly installed, will reduce radiation losses
from one to two per cent., over what can be accomplished with the best brick
setting without such casing and, in addition, prevent the loss due to the
infiltration of air, which may amount to an additional five per cent., as
compared with brick settings that are not maintained in good order. Steel
plate, or steel plate backed by asbestos mill-board, while acting as a
preventative against the infiltration of air through the boiler setting, is not as
effective from the standpoint of decreasing radiation losses as a casing
properly insulated from the brick portion of the setting by magnesia block
and asbestos mill-board. A casing which has been found to give excellent
results in eliminating air leakage and in the reduction of radiation losses is
clearly illustrated on page 306.
Many attempts have been made to use some material other than brick for
boiler settings but up to the present nothing has been found that may be
considered successful or which will give as satisfactory service under severe
conditions as properly laid brickwork.
FOOTNOTES
[75] For methods of determining, see Technologic Paper No. 7, Bureau of
Standards, page 44.
Page 424
[Pg 308]
Page 425
BOILER ROOM PIPING
In the design of a steam plant, the piping system should receive the most careful consideration. Aside from the
constructive details, good practice in which is fairly well established, the important factors are the size of the
piping to be employed and the methods utilized in avoiding difficulties from the presence in the system of water
of condensation and the means employed toward reducing radiation losses.
Engineering opinion varies considerably on the question of material of pipes and fittings for different classes of
work, and the following is offered simply as a suggestion of what constitutes good representative practice.
All pipe should be of wrought iron or soft steel. Pipe at present is made in “standard”, “extra strong”[76] and
“double extra strong” weights. Until recently, a fourth weight approximately 10 per cent lighter than standard
and known as “Merchants” was built but the use of this pipe has largely gone out of practice. Pipe sizes, unless
otherwise stated, are given in terms of nominal internal diameter. Table 62 gives the dimensions and some
general data on standard and extra strong wrought-iron pipe.
TABLE 62
DIMENSIONS OF STANDARD AND EXTRA STRONG[76] WROUGHT-IRON AND STEEL PIPE
Diameter Circumference Length
of Nominal Weight
External External Internal Pipe in Pounds per
Nominal Standard Internal Standard Internal Transverse Area Feet per
Foot
Size and and Square
Extra Extra Foot of
Strong Standard Extra Strong Standard Extra Standard Extra External Standard Extra
Strong Strong Strong Surface Strong
1⁄8 .405 .269 .215 1.272 .848 .675 .0573 .0363 9.440 .244 .314
1⁄4 .540 .364 .302 1.696 1.144 .949 .1041 .0716 7.075 .424 .535
3⁄8 .675 .493 .423 2.121 1.552 1.329 .1917 .1405 5.657 .567 .738
1⁄2 .840 .622 .546 2.639 1.957 1.715 .3048 .2341 4.547 .850 1.087
3⁄4 1.050 .824 .742 3.299 2.589 2.331 .5333 .4324 3.637 1.130 1.473
1 1.315 1.049 .957 4.131 3.292 3.007 .8626 .7193 2.904 1.678 2.171
11⁄4 1.660 1.380 1.278 5.215 4.335 4.015 1.496 1.287 2.301 2.272 2.996
11⁄2 1.900 1.610 1.500 5.969 5.061 4.712 2.038 1.767 2.010 2.717 3.631
2 2.375 2.067 1.939 7.461 6.494 6.092 3.356 2.953 1.608 3.652 5.022
21⁄2 2.875 2.469 2.323 9.032 7.753 7.298 4.784 4.238 1.328 5.793 7.661
3 3.500 3.068 2.900 10.996 9.636 9.111 7.388 6.605 1.091 7.575 10.252
31⁄2 4.000 3.548 3.364 12.566 11.146 10.568 9.887 8.888 .955 9.109 12.505
4 4.500 4.026 3.826 14.137 12.648 12.020 12.730 11.497 .849 10.790 14.983
41⁄2 5.000 4.506 4.290 15.708 14.162 13.477 15.961 14.454 .764 12.538 17.611
5 5.563 5.047 4.813 17.477 15.849 15.121 19.990 18.194 .687 14.617 20.778
6 6.625 6.065 5.761 20.813 19.054 18.099 28.888 26.067 .577 18.974 28.573
7 7.625 7.023 6.625 23.955 22.063 20.813 38.738 34.472 .501 23.544 38.048
8 8.625 7.981 7.625 27.096 25.076 23.955 50.040 45.664 .443 28.544 43.388
9 9.625 8.941 8.625 30.238 28.089 27.096 62.776 58.426 .397 33.907 48.728
10 10.750 10.020 9.750 33.772 31.477 30.631 78.839 74.662 .355 40.483 54.735
11 11.750 11.000 10.750 36.914 34.558 33.772 95.033 90.763 .325 45.557 60.075
12 12.750 12.000 11.750 40.055 37.700 36.914 113.098 108.43 .299 49.562 65.415
In the design of a steam plant, the piping system should receive the most careful consideration. Aside from the
constructive details, good practice in which is fairly well established, the important factors are the size of the
piping to be employed and the methods utilized in avoiding difficulties from the presence in the system of water
of condensation and the means employed toward reducing radiation losses.
Engineering opinion varies considerably on the question of material of pipes and fittings for different classes of
work, and the following is offered simply as a suggestion of what constitutes good representative practice.
All pipe should be of wrought iron or soft steel. Pipe at present is made in “standard”, “extra strong”[76] and
“double extra strong” weights. Until recently, a fourth weight approximately 10 per cent lighter than standard
and known as “Merchants” was built but the use of this pipe has largely gone out of practice. Pipe sizes, unless
otherwise stated, are given in terms of nominal internal diameter. Table 62 gives the dimensions and some
general data on standard and extra strong wrought-iron pipe.
TABLE 62
DIMENSIONS OF STANDARD AND EXTRA STRONG[76] WROUGHT-IRON AND STEEL PIPE
Diameter Circumference Length
of Nominal Weight
External External Internal Pipe in Pounds per
Nominal Standard Internal Standard Internal Transverse Area Feet per
Foot
Size and and Square
Extra Extra Foot of
Strong Standard Extra Strong Standard Extra Standard Extra External Standard Extra
Strong Strong Strong Surface Strong
1⁄8 .405 .269 .215 1.272 .848 .675 .0573 .0363 9.440 .244 .314
1⁄4 .540 .364 .302 1.696 1.144 .949 .1041 .0716 7.075 .424 .535
3⁄8 .675 .493 .423 2.121 1.552 1.329 .1917 .1405 5.657 .567 .738
1⁄2 .840 .622 .546 2.639 1.957 1.715 .3048 .2341 4.547 .850 1.087
3⁄4 1.050 .824 .742 3.299 2.589 2.331 .5333 .4324 3.637 1.130 1.473
1 1.315 1.049 .957 4.131 3.292 3.007 .8626 .7193 2.904 1.678 2.171
11⁄4 1.660 1.380 1.278 5.215 4.335 4.015 1.496 1.287 2.301 2.272 2.996
11⁄2 1.900 1.610 1.500 5.969 5.061 4.712 2.038 1.767 2.010 2.717 3.631
2 2.375 2.067 1.939 7.461 6.494 6.092 3.356 2.953 1.608 3.652 5.022
21⁄2 2.875 2.469 2.323 9.032 7.753 7.298 4.784 4.238 1.328 5.793 7.661
3 3.500 3.068 2.900 10.996 9.636 9.111 7.388 6.605 1.091 7.575 10.252
31⁄2 4.000 3.548 3.364 12.566 11.146 10.568 9.887 8.888 .955 9.109 12.505
4 4.500 4.026 3.826 14.137 12.648 12.020 12.730 11.497 .849 10.790 14.983
41⁄2 5.000 4.506 4.290 15.708 14.162 13.477 15.961 14.454 .764 12.538 17.611
5 5.563 5.047 4.813 17.477 15.849 15.121 19.990 18.194 .687 14.617 20.778
6 6.625 6.065 5.761 20.813 19.054 18.099 28.888 26.067 .577 18.974 28.573
7 7.625 7.023 6.625 23.955 22.063 20.813 38.738 34.472 .501 23.544 38.048
8 8.625 7.981 7.625 27.096 25.076 23.955 50.040 45.664 .443 28.544 43.388
9 9.625 8.941 8.625 30.238 28.089 27.096 62.776 58.426 .397 33.907 48.728
10 10.750 10.020 9.750 33.772 31.477 30.631 78.839 74.662 .355 40.483 54.735
11 11.750 11.000 10.750 36.914 34.558 33.772 95.033 90.763 .325 45.557 60.075
12 12.750 12.000 11.750 40.055 37.700 36.914 113.098 108.43 .299 49.562 65.415
Page 426
Dimensions are nominal and except where noted are in inches.
[Pg 309]
In connection with pipe sizes, Table 63, giving certain tube data may be found to be of service.
TABLE 63
TUBE DATA, STANDARD OPEN HEARTH OR LAP WELDED STEEL TUBES
Square Length
Transverse Area Feet of in Feet Nominal
Size Circumference
B. W. Internal Square Inches External per Square Weight
External Thickness
Gauge Diameter Surface Foot of Pounds
Diameter
per Foot External per Foot
External InternalExternal Internal
of Length Surface
11⁄2 10 .134 1.232 4.712 3.870 1.7671 1.1921 .392 2.546 1.955
11⁄2 9 .148 1.204 4.712 3.782 1.7671 1.1385 .392 2.546 2.137
11⁄2 8 .165 1.170 4.712 3.676 1.7671 1.0751 .392 2.546 2.353
2 10 .134 1.732 6.283 5.441 3.1416 2.3560 .523 1.909 2.670
2 9 .148 1.704 6.283 5.353 3.1416 2.2778 .523 1.909 2.927
2 8 .165 1.670 6.283 5.246 3.1416 2.1904 .523 1.909 3.234
31⁄4 11 .120 3.010 10.210 9.456 8.2958 7.1157 .850 1.175 4.011
31⁄4 10 .134 2.982 10.210 9.368 8.2958 6.9840 .850 1.175 4.459
31⁄4 9 .148 2.954 10.210 9.280 8.2958 6.8535 .850 1.175 4.903
4 10 .134 3.732 12.566 11.724 12.566 10.939 1.047 .954 5.532
4 9 .148 3.704 12.566 11.636 12.566 10.775 1.047 .954 6.000
4 8 .165 3.670 12.566 11.530 12.566 10.578 1.047 .954 6.758
Dimensions are nominal and except where noted are in inches.
Pipe Material and Thickness—For saturated steam pressures not exceeding 160 pounds, all pipe over 14 inches
should be 3⁄8 inch thick O. D. pipe. All other pipe should be standard full weight, except high pressure feed[77]
and blow-off lines, which should be extra strong.
For pressures above 150 pounds up to 200 pounds with superheated steam, all high pressure feed and blow-off
lines, high pressure steam lines having threaded flanges, and straight runs and bends of high pressure steam lines
6 inches and under having Van Stone joints should be extra strong. All piping 7 inches and over having Van
Stone joints should be full weight soft flanging pipe of special quality. Pipe 14 inches and over should be 3⁄8 inch
thick O. D. pipe. All pipes for these pressures not specified above should be full weight pipe.
Flanges—For saturated steam, 160 pounds working pressure, all flanges for wrought-iron pipe should be cast-
iron threaded. All high pressure threaded flanges should have the diameter thickness and drilling in accordance
with the “manufacturer’s standard” for “extra heavy” flanges. All low pressure flanges should have diameter,
thickness and drilling in accordance with “manufacturer’s standard” for “standard flanges.”
The flanges on high pressure lines should be counterbored to receive pipe and prevent the threads from
shouldering. The pipe should be screwed through the flange at least 1⁄16 inch, placed in machine and after facing
off the end one smooth cut should be taken over the face of the flange to make it square with the axis of the pipe.
For pressures above 160 pounds, where superheated steam is used, all high pressure steam lines 4 inches and
over should have solid rolled steel flanges and special [Pg 310]
[Pg 311] upset lapped joints. In the manufacture of such joints, the ends of the pipe are heated and upset against
the face of a holding mandrel conforming to the shape of the flange, the lapped portion of the pipe being
flattened out against the face of the mandrel, the upsetting action maintaining the desired thickness of the lap.
[Pg 309]
In connection with pipe sizes, Table 63, giving certain tube data may be found to be of service.
TABLE 63
TUBE DATA, STANDARD OPEN HEARTH OR LAP WELDED STEEL TUBES
Square Length
Transverse Area Feet of in Feet Nominal
Size Circumference
B. W. Internal Square Inches External per Square Weight
External Thickness
Gauge Diameter Surface Foot of Pounds
Diameter
per Foot External per Foot
External InternalExternal Internal
of Length Surface
11⁄2 10 .134 1.232 4.712 3.870 1.7671 1.1921 .392 2.546 1.955
11⁄2 9 .148 1.204 4.712 3.782 1.7671 1.1385 .392 2.546 2.137
11⁄2 8 .165 1.170 4.712 3.676 1.7671 1.0751 .392 2.546 2.353
2 10 .134 1.732 6.283 5.441 3.1416 2.3560 .523 1.909 2.670
2 9 .148 1.704 6.283 5.353 3.1416 2.2778 .523 1.909 2.927
2 8 .165 1.670 6.283 5.246 3.1416 2.1904 .523 1.909 3.234
31⁄4 11 .120 3.010 10.210 9.456 8.2958 7.1157 .850 1.175 4.011
31⁄4 10 .134 2.982 10.210 9.368 8.2958 6.9840 .850 1.175 4.459
31⁄4 9 .148 2.954 10.210 9.280 8.2958 6.8535 .850 1.175 4.903
4 10 .134 3.732 12.566 11.724 12.566 10.939 1.047 .954 5.532
4 9 .148 3.704 12.566 11.636 12.566 10.775 1.047 .954 6.000
4 8 .165 3.670 12.566 11.530 12.566 10.578 1.047 .954 6.758
Dimensions are nominal and except where noted are in inches.
Pipe Material and Thickness—For saturated steam pressures not exceeding 160 pounds, all pipe over 14 inches
should be 3⁄8 inch thick O. D. pipe. All other pipe should be standard full weight, except high pressure feed[77]
and blow-off lines, which should be extra strong.
For pressures above 150 pounds up to 200 pounds with superheated steam, all high pressure feed and blow-off
lines, high pressure steam lines having threaded flanges, and straight runs and bends of high pressure steam lines
6 inches and under having Van Stone joints should be extra strong. All piping 7 inches and over having Van
Stone joints should be full weight soft flanging pipe of special quality. Pipe 14 inches and over should be 3⁄8 inch
thick O. D. pipe. All pipes for these pressures not specified above should be full weight pipe.
Flanges—For saturated steam, 160 pounds working pressure, all flanges for wrought-iron pipe should be cast-
iron threaded. All high pressure threaded flanges should have the diameter thickness and drilling in accordance
with the “manufacturer’s standard” for “extra heavy” flanges. All low pressure flanges should have diameter,
thickness and drilling in accordance with “manufacturer’s standard” for “standard flanges.”
The flanges on high pressure lines should be counterbored to receive pipe and prevent the threads from
shouldering. The pipe should be screwed through the flange at least 1⁄16 inch, placed in machine and after facing
off the end one smooth cut should be taken over the face of the flange to make it square with the axis of the pipe.
For pressures above 160 pounds, where superheated steam is used, all high pressure steam lines 4 inches and
over should have solid rolled steel flanges and special [Pg 310]
[Pg 311] upset lapped joints. In the manufacture of such joints, the ends of the pipe are heated and upset against
the face of a holding mandrel conforming to the shape of the flange, the lapped portion of the pipe being
flattened out against the face of the mandrel, the upsetting action maintaining the desired thickness of the lap.
Page 427
When cool, both sides of the lap are faced to form a uniform thickness and an even bearing against flange and
gasket. The joint, therefore, is a strictly metal to metal joint, the flanges merely holding the lapped ends of the
pipe against the gasket.
2000 Horse-power Installation of Babcock & Wilcox Boilers and Superheaters, Equipped with Babcock &
Wilcox Chain Grate Stokers at the Kentucky Electric Co., Louisville, Ky.
A special grade of soft flanging pipe is selected to prevent breaking. The bending action is a severe test of the
pipe and if it withstands the bending process and the pressure tests, the reliability of the joint is assured. Such a
joint is called a Van Stone joint, though many modifications and improvements have been made since the joint
was originally introduced.
The diameter and thickness of such flanges should be special extra heavy. Such flanges should be turned to
diameter, their fronts faced and the backs machined in lieu of spot facing.
In lines other than given for pressures over 150 pounds, all flanges for wrought-iron pipe should be threaded. All
threaded flanges for high pressure superheated lines 3½ inches and under should be “semi-steel” extra heavy.
Flanges for other than steam lines should be manufacturer’s standard extra heavy.
Welded flanges are frequently used in place of those described with satisfactory results.
Fittings—For saturated steam under pressures up to 160 pounds, all fittings 3½ inches and under should be
screwed. Fittings 4 inches and over should have flanged ends. Fittings for this pressure should be of cast iron
and should have heavy leads and full taper threads. Flanged fittings in high pressure lines should be extra heavy,
and in low pressure lines standard weight. Where possible in high pressure flanges and fittings, bolt surfaces
should be spot faced to provide suitable bearing for bolt heads and nuts.
Fittings for superheated steam up to 70 degrees at pressures above 160 pounds are sometimes of cast iron.[78]
For superheat above 70 degrees such fittings should be “steel castings” and in general these fittings are
recommended for any degree of superheat. Fittings for other than high pressure work may be of cast iron, except
where superheated steam is carried, where they should be of “wrought steel” or “hard metal”. Fittings 3½ inches
and under should be screwed, 4 inches and over flanged.
gasket. The joint, therefore, is a strictly metal to metal joint, the flanges merely holding the lapped ends of the
pipe against the gasket.
2000 Horse-power Installation of Babcock & Wilcox Boilers and Superheaters, Equipped with Babcock &
Wilcox Chain Grate Stokers at the Kentucky Electric Co., Louisville, Ky.
A special grade of soft flanging pipe is selected to prevent breaking. The bending action is a severe test of the
pipe and if it withstands the bending process and the pressure tests, the reliability of the joint is assured. Such a
joint is called a Van Stone joint, though many modifications and improvements have been made since the joint
was originally introduced.
The diameter and thickness of such flanges should be special extra heavy. Such flanges should be turned to
diameter, their fronts faced and the backs machined in lieu of spot facing.
In lines other than given for pressures over 150 pounds, all flanges for wrought-iron pipe should be threaded. All
threaded flanges for high pressure superheated lines 3½ inches and under should be “semi-steel” extra heavy.
Flanges for other than steam lines should be manufacturer’s standard extra heavy.
Welded flanges are frequently used in place of those described with satisfactory results.
Fittings—For saturated steam under pressures up to 160 pounds, all fittings 3½ inches and under should be
screwed. Fittings 4 inches and over should have flanged ends. Fittings for this pressure should be of cast iron
and should have heavy leads and full taper threads. Flanged fittings in high pressure lines should be extra heavy,
and in low pressure lines standard weight. Where possible in high pressure flanges and fittings, bolt surfaces
should be spot faced to provide suitable bearing for bolt heads and nuts.
Fittings for superheated steam up to 70 degrees at pressures above 160 pounds are sometimes of cast iron.[78]
For superheat above 70 degrees such fittings should be “steel castings” and in general these fittings are
recommended for any degree of superheat. Fittings for other than high pressure work may be of cast iron, except
where superheated steam is carried, where they should be of “wrought steel” or “hard metal”. Fittings 3½ inches
and under should be screwed, 4 inches and over flanged.
Page 428
Flanges for pressures up to 160 pounds in pipes and fittings for low pressure lines, and any fittings for high
pressure lines should have plain faces, smooth tool finish, scored with V-shaped grooves for rubber gaskets.
High pressure line flanges should have raised faces, projecting the full available diameter inside the bolt holes.
These faces should be similarly scored.
All pipe ½ inch and under should have ground joint unions suitable for the pressure required. Pipe ¾ inch and
over should have cast-iron flanged unions. Unions are to be preferred to wrought-iron couplings wherever
possible to facilitate dismantling.
Valves—For 150 pounds working pressure, saturated steam, all valves 2 inches and under may have screwed
ends; 2½ inches and over should be flanged. All high pressure steam valves 6 inches and over should have
suitable by-passes. All valves [Pg 312] for use with superheated steam should be of special construction. For
pressures above 160 pounds, where the superheat does not exceed 70 degrees, valve bodies, caps and yokes are
sometimes made of cast iron, though ordinarily semi-steel will give better satisfaction. The spindles of such
valves should be of bronze and there should be special necks with condensing chambers to prevent the
superheated steam from blowing through the packing. For pressures over 160 pounds and degrees of superheat
above 70, all valves 3 inches and over should have valve bodies, caps and yokes of steel castings. Spindles
should be of some non-corrosive metal, such as “monel metal”. Seat rings should be removable of the same non-
corrosive metal as should the spindle seats and plug faces.
All salt water valves should have bronze spindles, sleeves and packing seats.
The suggestions as to flanges for different classes of service made on page 311 hold as well for valve flanges,
except that such flanges are not scored.
Automatic stop and check valves are coming into general use with boilers and such use is compulsory under the
boiler regulations of certain communities. Where used, they should be preferably placed directly on the boiler
nozzle. Where two or more boilers are on one line, in addition to the valve at the boiler, whether this be an
automatic valve or a gate valve, there should be an additional gate valve on each boiler branch at the main steam
header.
Relief valves should be furnished at the discharge side of each feed pump and on the discharge side of each feed
heater of the closed type.
Feed Lines—Feed lines should in all instances be made of extra strong pipe due to the corrosive action of hot
feed water. While it has been suggested above that cast-iron threaded flanges should be used in such lines, due to
the sudden expansion of such pipe in certain instances cast-iron threaded flanges crack before they become
thoroughly heated and expand, and for this reason cast-steel threaded flanges will give more satisfactory results.
In some instances, wrought-steel and Van Stone joints have been used in feed lines and this undoubtedly is better
practice than the use of cast-steel threaded work, though the additional cost is not warranted in all stations.
Feed valves should always be of the globe pattern. A gate valve cannot be closely regulated and often clatters
owing to the pulsations of the feed pump.
Gaskets—For steam and water lines where the pressure does not exceed 160 pounds, wire insertion rubber
gaskets 1⁄16 inch thick will be found to give good service. For low pressure lines, canvas insertion black rubber
gaskets are ordinarily used. For oil lines special gaskets are necessary.
For pressure above 160 pounds carrying superheated steam, corrugated steel gaskets extending the full available
diameter inside of the bolt holes give good satisfaction. For high pressure water lines wire inserted rubber
gaskets are used, and for low pressure flanged joints canvas inserted rubber gaskets.
Size of Steam Lines—The factors affecting the proper size of steam lines are the radiation from such lines and
the velocity of steam within them. As the size of the steam line increases, there will be an increase in the
radiation.[79] As the size decreases, the steam velocity and the pressure drop for a given quantity of steam
naturally increases.
pressure lines should have plain faces, smooth tool finish, scored with V-shaped grooves for rubber gaskets.
High pressure line flanges should have raised faces, projecting the full available diameter inside the bolt holes.
These faces should be similarly scored.
All pipe ½ inch and under should have ground joint unions suitable for the pressure required. Pipe ¾ inch and
over should have cast-iron flanged unions. Unions are to be preferred to wrought-iron couplings wherever
possible to facilitate dismantling.
Valves—For 150 pounds working pressure, saturated steam, all valves 2 inches and under may have screwed
ends; 2½ inches and over should be flanged. All high pressure steam valves 6 inches and over should have
suitable by-passes. All valves [Pg 312] for use with superheated steam should be of special construction. For
pressures above 160 pounds, where the superheat does not exceed 70 degrees, valve bodies, caps and yokes are
sometimes made of cast iron, though ordinarily semi-steel will give better satisfaction. The spindles of such
valves should be of bronze and there should be special necks with condensing chambers to prevent the
superheated steam from blowing through the packing. For pressures over 160 pounds and degrees of superheat
above 70, all valves 3 inches and over should have valve bodies, caps and yokes of steel castings. Spindles
should be of some non-corrosive metal, such as “monel metal”. Seat rings should be removable of the same non-
corrosive metal as should the spindle seats and plug faces.
All salt water valves should have bronze spindles, sleeves and packing seats.
The suggestions as to flanges for different classes of service made on page 311 hold as well for valve flanges,
except that such flanges are not scored.
Automatic stop and check valves are coming into general use with boilers and such use is compulsory under the
boiler regulations of certain communities. Where used, they should be preferably placed directly on the boiler
nozzle. Where two or more boilers are on one line, in addition to the valve at the boiler, whether this be an
automatic valve or a gate valve, there should be an additional gate valve on each boiler branch at the main steam
header.
Relief valves should be furnished at the discharge side of each feed pump and on the discharge side of each feed
heater of the closed type.
Feed Lines—Feed lines should in all instances be made of extra strong pipe due to the corrosive action of hot
feed water. While it has been suggested above that cast-iron threaded flanges should be used in such lines, due to
the sudden expansion of such pipe in certain instances cast-iron threaded flanges crack before they become
thoroughly heated and expand, and for this reason cast-steel threaded flanges will give more satisfactory results.
In some instances, wrought-steel and Van Stone joints have been used in feed lines and this undoubtedly is better
practice than the use of cast-steel threaded work, though the additional cost is not warranted in all stations.
Feed valves should always be of the globe pattern. A gate valve cannot be closely regulated and often clatters
owing to the pulsations of the feed pump.
Gaskets—For steam and water lines where the pressure does not exceed 160 pounds, wire insertion rubber
gaskets 1⁄16 inch thick will be found to give good service. For low pressure lines, canvas insertion black rubber
gaskets are ordinarily used. For oil lines special gaskets are necessary.
For pressure above 160 pounds carrying superheated steam, corrugated steel gaskets extending the full available
diameter inside of the bolt holes give good satisfaction. For high pressure water lines wire inserted rubber
gaskets are used, and for low pressure flanged joints canvas inserted rubber gaskets.
Size of Steam Lines—The factors affecting the proper size of steam lines are the radiation from such lines and
the velocity of steam within them. As the size of the steam line increases, there will be an increase in the
radiation.[79] As the size decreases, the steam velocity and the pressure drop for a given quantity of steam
naturally increases.
Page 429
There is a marked tendency in modern practice toward higher steam velocities, particularly in the case of
superheated steam. It was formerly considered good practice to limit this velocity to 6000 feet per minute but
this figure is to-day considered low.
[Pg 313]
In practice the limiting factor in the velocity advisable is the allowable pressure drop. In the description of the
action of the throttling calorimeter, it has been demonstrated that there is no loss accompanying a drop in
pressure, the difference in energy between the higher and lower pressures appearing as heat, which, in the case
of steam flowing through a pipe, may evaporate any condensation present or may be radiated from the pipe. A
decrease in pipe area decreases the radiating surface of the pipe and thus the possible condensation. As the heat
liberated by the pressure drop is utilized in overcoming or diminishing the tendency toward condensation and
the heat loss through radiation, the steam as it enters the prime mover will be drier or more highly superheated
where high steam velocities are used than where they are lower, and if enough excess pressure is carried at the
boilers to maintain the desired pressure at the prime mover, the pressure drop results in an actual saving rather
than a loss. The whole is analogous to standard practice in electrical distributing systems where generator
voltage is adjusted to suit the loss in the feeder lines.
In modern practice, with superheated steam, velocities of 15,000 feet per minute are not unusual and this figure
is very frequently exceeded.
Piping System Design—With the proper size of pipe to be used determined, the most important factor is the
provision for the removal of water of condensation that will occur in any system. Such condensation cannot be
wholly overcome and if the water of condensation is carried to the prime mover, difficulties will invariably
result. Water is practically incompressible and its effect when traveling at high velocities differs little from that
of a solid body of equal weight, hence impact against elbows, valves or other obstructions, is the equivalent of a
heavy hammer blow that may result in the fracture of the pipe. If there is not sufficient water in the system to
produce this result, it will certainly cause knocking and vibration in the pipe, resulting eventually in leaky joints.
Where the water reaches the prime mover, its effect will vary from disagreeable knocking to disruption. Too
frequently when there are disastrous results from such a cause the boilers are blamed for delivering wet steam
when, as a matter of fact, the evil is purely a result of poor piping design, the most common cause of such an
action being the pocketing of the water in certain parts of the piping from whence it is carried along in slugs by
the steam. The action is particularly severe if steam is admitted to a cold pipe containing water, as the water may
then form a partial vacuum by condensing the steam and be projected at a very high velocity through the pipes
producing a characteristic sharp metallic knock which often causes bursting of the pipe or fittings. The amount
of water present through condensation may be appreciated when it is considered that uncovered 6-inch pipe 150
feet long carrying 3600 pounds of high pressure steam per hour will condense approximately 6 per cent of the
total steam carried through radiation. It follows that efficient means of removing condensation water are
absolutely imperative and the following suggestions as to such means may be of service:
The pitch of all pipe should be in the direction of the flow of steam. Wherever a rise is necessary, a drain should
be installed. All main headers and important branches should end in a drop leg and each such drop leg and any
low points in the system should be connected to the drainage pump. A similar connection should be made to
every fitting where there is danger of a water pocket.
Branch lines should never be taken from the bottom of a main header but where possible should be taken from
the top. Each engine supply pipe should have its own [Pg 314] separator placed as near the throttle as possible.
Such separators should be drained to the drainage system.
Check valves are frequently placed in drain pipes to prevent steam from entering any portion of the system that
may be shut off.
Valves should be so located that they cannot form water pockets when either open or closed. Globe valves will
form a water pocket in the piping to which they are connected unless set with the stem horizontal, while gate
valves may be set with the spindle vertical or at an angle. Where valves are placed directly on the boiler nozzle,
a drain should be provided above them.
superheated steam. It was formerly considered good practice to limit this velocity to 6000 feet per minute but
this figure is to-day considered low.
[Pg 313]
In practice the limiting factor in the velocity advisable is the allowable pressure drop. In the description of the
action of the throttling calorimeter, it has been demonstrated that there is no loss accompanying a drop in
pressure, the difference in energy between the higher and lower pressures appearing as heat, which, in the case
of steam flowing through a pipe, may evaporate any condensation present or may be radiated from the pipe. A
decrease in pipe area decreases the radiating surface of the pipe and thus the possible condensation. As the heat
liberated by the pressure drop is utilized in overcoming or diminishing the tendency toward condensation and
the heat loss through radiation, the steam as it enters the prime mover will be drier or more highly superheated
where high steam velocities are used than where they are lower, and if enough excess pressure is carried at the
boilers to maintain the desired pressure at the prime mover, the pressure drop results in an actual saving rather
than a loss. The whole is analogous to standard practice in electrical distributing systems where generator
voltage is adjusted to suit the loss in the feeder lines.
In modern practice, with superheated steam, velocities of 15,000 feet per minute are not unusual and this figure
is very frequently exceeded.
Piping System Design—With the proper size of pipe to be used determined, the most important factor is the
provision for the removal of water of condensation that will occur in any system. Such condensation cannot be
wholly overcome and if the water of condensation is carried to the prime mover, difficulties will invariably
result. Water is practically incompressible and its effect when traveling at high velocities differs little from that
of a solid body of equal weight, hence impact against elbows, valves or other obstructions, is the equivalent of a
heavy hammer blow that may result in the fracture of the pipe. If there is not sufficient water in the system to
produce this result, it will certainly cause knocking and vibration in the pipe, resulting eventually in leaky joints.
Where the water reaches the prime mover, its effect will vary from disagreeable knocking to disruption. Too
frequently when there are disastrous results from such a cause the boilers are blamed for delivering wet steam
when, as a matter of fact, the evil is purely a result of poor piping design, the most common cause of such an
action being the pocketing of the water in certain parts of the piping from whence it is carried along in slugs by
the steam. The action is particularly severe if steam is admitted to a cold pipe containing water, as the water may
then form a partial vacuum by condensing the steam and be projected at a very high velocity through the pipes
producing a characteristic sharp metallic knock which often causes bursting of the pipe or fittings. The amount
of water present through condensation may be appreciated when it is considered that uncovered 6-inch pipe 150
feet long carrying 3600 pounds of high pressure steam per hour will condense approximately 6 per cent of the
total steam carried through radiation. It follows that efficient means of removing condensation water are
absolutely imperative and the following suggestions as to such means may be of service:
The pitch of all pipe should be in the direction of the flow of steam. Wherever a rise is necessary, a drain should
be installed. All main headers and important branches should end in a drop leg and each such drop leg and any
low points in the system should be connected to the drainage pump. A similar connection should be made to
every fitting where there is danger of a water pocket.
Branch lines should never be taken from the bottom of a main header but where possible should be taken from
the top. Each engine supply pipe should have its own [Pg 314] separator placed as near the throttle as possible.
Such separators should be drained to the drainage system.
Check valves are frequently placed in drain pipes to prevent steam from entering any portion of the system that
may be shut off.
Valves should be so located that they cannot form water pockets when either open or closed. Globe valves will
form a water pocket in the piping to which they are connected unless set with the stem horizontal, while gate
valves may be set with the spindle vertical or at an angle. Where valves are placed directly on the boiler nozzle,
a drain should be provided above them.
Page 430
High pressure drains should be trapped to both feed heaters and waste headers. Traps and meters should be
provided with by-passes. Cylinder drains, heater blow-offs and drains, boiler blow-offs and similar lines should
be led to waste. The ends of cylinder drains should not extend below the surface of water, for on starting up or
on closing the throttle valve with the drains open, water may be drawn back into the cylinders.
TABLE 64
RADIATION FROM COVERED AND UNCOVERED STEAM PIPES
CALCULATED FOR 160 POUNDS PRESSURE AND 60 DEGREES TEMPERATURE
Pipe
Thickness of Covering 1⁄2 inch 3⁄4 inch 1 inch 11⁄4 inch 11⁄2 inch Bare
Inches
B. t. u. per lineal foot per hour 149 118 99 86 79 597
B. t. u. per square foot per hour 240 190 161 138 127 959
2
B. t. u. per square foot per hour per
.770 .613 .519 .445 .410 3.198
one degree difference in temperature
B. t. u. per lineal foot per hour 247 193 160 139 123 1085
B. t. u. per square foot per hour 210 164 136 118 104 921
4
B. t. u. per square foot per hour per
.677 .592 .439 .381 .335 2.970
one degree difference in temperature
B. t. u. per lineal foot per hour 352 269 221 190 167 1555
B. t. u. per square foot per hour 203 155 127 110 96 897
6
B. t. u. per square foot per hour per
.655 .500 .410 .355 .310 2.89
one degree difference in temperature
B. t. u. per lineal foot per hour 443 337 276 235 207 1994
B. t. u. per square foot per hour 196 149 122 104 92 883
8
B. t. u. per square foot per hour per
.632 .481 .394 .335 .297 2.85
one degree difference in temperature
B. t. u. per lineal foot per hour 549 416 337 287 250 2468
B. t. u. per square foot per hour 195 148 120 102 89 877
10
B. t. u. per square foot per hour per
.629 .477 .387 .329 .287 2.83
one degree difference in temperature
Covering—Magnesia, canvas covered.
For calculating radiation for pressure and temperature other than 160 pounds, and 60 degrees, use B. t. u. figures
for one degree difference.
Radiation from Pipes—The evils of the presence of condensed steam in piping systems have been thoroughly
discussed above and in some of the previous articles. [Pg 315] Condensation resulting from radiation, while it
cannot be wholly obviated, can, by proper installation, be greatly reduced.
Bare pipe will radiate approximately 3 B. t. u. per hour per square foot of exposed surface per one degree of
difference in temperature between the steam contained and the external air. This figure may be reduced to from
0.3 to 0.4 B. t. u. for the same conditions by a 1½ inch insulating covering. Table 64 gives the radiation losses
for bare and covered pipes with different thicknesses of magnesia covering.
TABLE 65 Many experiments have been made as to the relative efficiencies of
different kinds of covering. Table 65 gives some approximately relative
APPROXIMATE figures based on one inch covering from experiments by Paulding,
EFFICIENCIES OF VARIOUS Jacobus, Brill and others.
COVERINGS REFERRED TO
BARE PIPES Based on one-inch covering.
Covering Efficiency
The following suggestions may be of service:
provided with by-passes. Cylinder drains, heater blow-offs and drains, boiler blow-offs and similar lines should
be led to waste. The ends of cylinder drains should not extend below the surface of water, for on starting up or
on closing the throttle valve with the drains open, water may be drawn back into the cylinders.
TABLE 64
RADIATION FROM COVERED AND UNCOVERED STEAM PIPES
CALCULATED FOR 160 POUNDS PRESSURE AND 60 DEGREES TEMPERATURE
Pipe
Thickness of Covering 1⁄2 inch 3⁄4 inch 1 inch 11⁄4 inch 11⁄2 inch Bare
Inches
B. t. u. per lineal foot per hour 149 118 99 86 79 597
B. t. u. per square foot per hour 240 190 161 138 127 959
2
B. t. u. per square foot per hour per
.770 .613 .519 .445 .410 3.198
one degree difference in temperature
B. t. u. per lineal foot per hour 247 193 160 139 123 1085
B. t. u. per square foot per hour 210 164 136 118 104 921
4
B. t. u. per square foot per hour per
.677 .592 .439 .381 .335 2.970
one degree difference in temperature
B. t. u. per lineal foot per hour 352 269 221 190 167 1555
B. t. u. per square foot per hour 203 155 127 110 96 897
6
B. t. u. per square foot per hour per
.655 .500 .410 .355 .310 2.89
one degree difference in temperature
B. t. u. per lineal foot per hour 443 337 276 235 207 1994
B. t. u. per square foot per hour 196 149 122 104 92 883
8
B. t. u. per square foot per hour per
.632 .481 .394 .335 .297 2.85
one degree difference in temperature
B. t. u. per lineal foot per hour 549 416 337 287 250 2468
B. t. u. per square foot per hour 195 148 120 102 89 877
10
B. t. u. per square foot per hour per
.629 .477 .387 .329 .287 2.83
one degree difference in temperature
Covering—Magnesia, canvas covered.
For calculating radiation for pressure and temperature other than 160 pounds, and 60 degrees, use B. t. u. figures
for one degree difference.
Radiation from Pipes—The evils of the presence of condensed steam in piping systems have been thoroughly
discussed above and in some of the previous articles. [Pg 315] Condensation resulting from radiation, while it
cannot be wholly obviated, can, by proper installation, be greatly reduced.
Bare pipe will radiate approximately 3 B. t. u. per hour per square foot of exposed surface per one degree of
difference in temperature between the steam contained and the external air. This figure may be reduced to from
0.3 to 0.4 B. t. u. for the same conditions by a 1½ inch insulating covering. Table 64 gives the radiation losses
for bare and covered pipes with different thicknesses of magnesia covering.
TABLE 65 Many experiments have been made as to the relative efficiencies of
different kinds of covering. Table 65 gives some approximately relative
APPROXIMATE figures based on one inch covering from experiments by Paulding,
EFFICIENCIES OF VARIOUS Jacobus, Brill and others.
COVERINGS REFERRED TO
BARE PIPES Based on one-inch covering.
Covering Efficiency
The following suggestions may be of service:
Page 431
Covering Efficiency Exposed radiating surfaces of all pipes, all high pressure steam flanges,
Asbestocel 76.8 valve bodies and fittings, heaters and separators, should be covered with
Gast’s Air Cell 74.4 non-conducting material wherever such covering will improve plant
Asbesto Sponge Felt 85.0 economy. All main steam lines, engine and boiler branches, should be
Magnesia 83.5 covered with 2 inches of 85 per cent carbonate of magnesia or the
equivalent. Other lines may be covered with one inch of the same
Asbestos Navy Brand 82.0
material. All covering should be sectional in form and large surfaces
Asbesto Sponge Hair 86.0 should be covered with blocks, except where such material would be
Asbestos Fire Felt 73.5 difficult to install, in which case plastic material should be used. In the
case of flanges the covering should be tapered back from the flange in
order that the bolts may be removed.
All surfaces should be painted before the covering is applied. Canvas is ordinarily placed over the covering, held
in place by wrought-iron or brass bands.
Expansion and Support of Pipe—It is highly important that the piping be so run that there will be no undue
strains through the action of expansion. Certain points are usually securely anchored and the expansion of the
piping at other points taken care of by providing supports along which the piping will slide or by means of
flexible hangers. Where pipe is supported or anchored, it should be from the building structure and not from
boilers or prime movers. Where supports are furnished, they should in general be of any of the numerous sliding
supports that are available. Expansion is taken care of by such a method of support and by the providing of large
radius bends where necessary.
It was formerly believed that piping would actually expand under steam temperatures about one-half the
theoretical amount due to the fact that the exterior of the pipe would not reach the full temperature of the steam
contained. It would appear, however from recent experiments that such actual expansion will in the case of well-
covered pipe be very nearly the theoretical amount. In one case noted, a steam header 293 feet long when heated
under a working pressure of 190 pounds, the steam superheated approximately 125 degrees, expanded 8¾
inches; the theoretical amount of expansion under the conditions would be approximately 935⁄64 inches.
[Pg 316]
Asbestocel 76.8 valve bodies and fittings, heaters and separators, should be covered with
Gast’s Air Cell 74.4 non-conducting material wherever such covering will improve plant
Asbesto Sponge Felt 85.0 economy. All main steam lines, engine and boiler branches, should be
Magnesia 83.5 covered with 2 inches of 85 per cent carbonate of magnesia or the
equivalent. Other lines may be covered with one inch of the same
Asbestos Navy Brand 82.0
material. All covering should be sectional in form and large surfaces
Asbesto Sponge Hair 86.0 should be covered with blocks, except where such material would be
Asbestos Fire Felt 73.5 difficult to install, in which case plastic material should be used. In the
case of flanges the covering should be tapered back from the flange in
order that the bolts may be removed.
All surfaces should be painted before the covering is applied. Canvas is ordinarily placed over the covering, held
in place by wrought-iron or brass bands.
Expansion and Support of Pipe—It is highly important that the piping be so run that there will be no undue
strains through the action of expansion. Certain points are usually securely anchored and the expansion of the
piping at other points taken care of by providing supports along which the piping will slide or by means of
flexible hangers. Where pipe is supported or anchored, it should be from the building structure and not from
boilers or prime movers. Where supports are furnished, they should in general be of any of the numerous sliding
supports that are available. Expansion is taken care of by such a method of support and by the providing of large
radius bends where necessary.
It was formerly believed that piping would actually expand under steam temperatures about one-half the
theoretical amount due to the fact that the exterior of the pipe would not reach the full temperature of the steam
contained. It would appear, however from recent experiments that such actual expansion will in the case of well-
covered pipe be very nearly the theoretical amount. In one case noted, a steam header 293 feet long when heated
under a working pressure of 190 pounds, the steam superheated approximately 125 degrees, expanded 8¾
inches; the theoretical amount of expansion under the conditions would be approximately 935⁄64 inches.
[Pg 316]
Page 432
Bankers Trust Building, New York City, Operation 900 Horse Power of Babcock & Wilcox Boilers
FOOTNOTES
[76] Often called extra heavy pipe.
[77] See Feed Piping, page 312.
[78] See Superheat Chapter, page 145.
[79] See Radiation from Steam Lines, page 314.
FOOTNOTES
[76] Often called extra heavy pipe.
[77] See Feed Piping, page 312.
[78] See Superheat Chapter, page 145.
[79] See Radiation from Steam Lines, page 314.
Page 433
[Pg 317]
Page 434
FLOW OF STEAM THROUGH PIPES AND ORIFICES
Various formulae for the flow of steam through pipes have been advanced, all having their basis upon
Bernoulli’s theorem of the flow of water through circular pipes with the proper modifications made for
the variation in constants between steam and water. The loss of energy due to friction in a pipe is given
by Unwin (based upon Weisbach) as
f2v²WL
Ef = ––––––––––––––––– ( 37 )
gd
where E is the energy loss in foot pounds due to the friction of W units of weight of steam passing with a
velocity of v feet per second through a pipe d feet in diameter and L feet long; g represents the
acceleration due to gravity (32.2) and f the coefficient of friction.
Numerous values have been given for this coefficient of friction, f , which, from experiment, apparently
varies with both the diameter of pipe and the velocity of the passing steam. There is no authentic data on
the rate of this variation with velocity and, as in all experiments, the effect of change of velocity has
seemed less than the unavoidable errors of observation, the coefficient is assumed to vary only with the
size of the pipe.
Unwin established a relation for this coefficient for steam at a velocity of 100 feet per second,
3
(
f = K 1 + –––––––
10 d
) ( 38 )
where K is a constant experimentally determined, and d the internal diameter of the pipe in feet.
If h represents the loss of head in feet, then
f2v²WL
Ef = Wh = ––––––––––––––––– ( 39 )
gd
f2v²L
and h = –––––––––––– ( 40 )
gd
If D represents the density of the steam or weight per cubic foot, and p the loss of pressure due to friction
in pounds per square inch, then
hD
p = –––––– ( 41 )
144
and from equations ( 38 ), ( 40 ) and ( 41 ),
Various formulae for the flow of steam through pipes have been advanced, all having their basis upon
Bernoulli’s theorem of the flow of water through circular pipes with the proper modifications made for
the variation in constants between steam and water. The loss of energy due to friction in a pipe is given
by Unwin (based upon Weisbach) as
f2v²WL
Ef = ––––––––––––––––– ( 37 )
gd
where E is the energy loss in foot pounds due to the friction of W units of weight of steam passing with a
velocity of v feet per second through a pipe d feet in diameter and L feet long; g represents the
acceleration due to gravity (32.2) and f the coefficient of friction.
Numerous values have been given for this coefficient of friction, f , which, from experiment, apparently
varies with both the diameter of pipe and the velocity of the passing steam. There is no authentic data on
the rate of this variation with velocity and, as in all experiments, the effect of change of velocity has
seemed less than the unavoidable errors of observation, the coefficient is assumed to vary only with the
size of the pipe.
Unwin established a relation for this coefficient for steam at a velocity of 100 feet per second,
3
(
f = K 1 + –––––––
10 d
) ( 38 )
where K is a constant experimentally determined, and d the internal diameter of the pipe in feet.
If h represents the loss of head in feet, then
f2v²WL
Ef = Wh = ––––––––––––––––– ( 39 )
gd
f2v²L
and h = –––––––––––– ( 40 )
gd
If D represents the density of the steam or weight per cubic foot, and p the loss of pressure due to friction
in pounds per square inch, then
hD
p = –––––– ( 41 )
144
and from equations ( 38 ), ( 40 ) and ( 41 ),
Page 435
Dv²L 3
72 g d
(
p = ––––––––––– × K 1 + –––––––
10 d
) ( 42 )
To convert the velocity term and to reduce to units ordinarily used, let d 1 the diameter of pipe in inches
= 12 d , and w = the flow in pounds per minute; then
π d1
w = 60 v × –– ––––
4 12
D( )²
9.6 w
and v = –––––––––––
πd1²D
[Pg 318]
Substituting this value and that of d in formula ( 42 )
3.6 w ² L
(
p = 0.04839 K 1 + ––––– ––––––––
d1 Dd15
) ( 43 )
Some of the experimental determinations for the value of K are:
K = .005 for water (Unwin).
K = .005 for air (Arson).
K = .0028 for air (St. Gothard tunnel experiments).
K = .0026 for steam (Carpenter at Oriskany).
K = .0027 for steam (G. H. Babcock).
The value .0027 is apparently the most nearly correct, and substituting in formula ( 43 ) gives,
3.6 w ² L
(
p = 0.000131 1 + ––––– ––––––––
d1 Dd15
) ( 44 )
pDd15
––––––––––––––––––––––––––
w = 87 ( 1 + 3.6 L ) ½ ( 45 )
( d ) –––––
1
Where w = the weight of steam passing in pounds per minute,
p = the difference in pressure between the two ends of the pipe in pounds per square inch,
D = density of steam or weight per cubic foot, [80]
d 1 = internal diameter of pipe in inches,
L = length of pipe in feet.
72 g d
(
p = ––––––––––– × K 1 + –––––––
10 d
) ( 42 )
To convert the velocity term and to reduce to units ordinarily used, let d 1 the diameter of pipe in inches
= 12 d , and w = the flow in pounds per minute; then
π d1
w = 60 v × –– ––––
4 12
D( )²
9.6 w
and v = –––––––––––
πd1²D
[Pg 318]
Substituting this value and that of d in formula ( 42 )
3.6 w ² L
(
p = 0.04839 K 1 + ––––– ––––––––
d1 Dd15
) ( 43 )
Some of the experimental determinations for the value of K are:
K = .005 for water (Unwin).
K = .005 for air (Arson).
K = .0028 for air (St. Gothard tunnel experiments).
K = .0026 for steam (Carpenter at Oriskany).
K = .0027 for steam (G. H. Babcock).
The value .0027 is apparently the most nearly correct, and substituting in formula ( 43 ) gives,
3.6 w ² L
(
p = 0.000131 1 + ––––– ––––––––
d1 Dd15
) ( 44 )
pDd15
––––––––––––––––––––––––––
w = 87 ( 1 + 3.6 L ) ½ ( 45 )
( d ) –––––
1
Where w = the weight of steam passing in pounds per minute,
p = the difference in pressure between the two ends of the pipe in pounds per square inch,
D = density of steam or weight per cubic foot, [80]
d 1 = internal diameter of pipe in inches,
L = length of pipe in feet.
Page 436
TABLE 66
FLOW OF STEAM THROUGH PIPES
Initial
Gauge Diameter [81] of Pipe in Inches, Length of Pipe = 240 Diameters
Pressure
Pounds ¾ 1 1½ 2 2½ 3 4 5 6 8 10 12 15 18
per
Square Weight of Steam per Minute, in Pounds, With One Pound Loss of Pressure
Inch
1 1.16 2.07 5.7 10.27 15.45 25.38 46.85 77.3 115.9 211.4 341.1 502.4 804 1177
10 1.44 2.57 7.1 12.72 19.15 31.45 58.05 95.8 143.6262.0 422.7 622.5 9961458
20 1.70 3.02 8.3 14.94 22.49 36.94 68.20 112.6 168.7307.8 496.5 731.3 1170 1713
30 1.91 3.40 9.4 16.84 25.35 41.63 76.84 126.9 190.1346.8 559.5 824.1 13181930
40 2.10 3.74 10.3 18.51 27.87 45.77 84.49 139.5 209.0381.3 615.3 906.0 14502122
50 2.27 4.04 11.2 20.01 30.13 49.48 91.34 150.8 226.0412.2 665.0 979.5 15672294
60 2.43 4.32 11.9 21.38 32.19 52.87 97.60 161.1 241.5440.5 710.61046.7 16752451
70 2.57 4.58 12.6 22.65 34.10 56.00103.37 170.7 255.8466.5 752.7 1108.5 17742596
80 2.71 4.82 13.3 23.82 35.87 58.91108.74 179.5 269.0490.7 791.7 1166.1 18662731
90 2.83 5.04 13.9 24.92 37.52 61.62 113.74 187.8 281.4513.3 828.11219.8 19512856
100 2.95 5.25 14.5 25.96 39.07 64.18 118.47 195.6 293.1534.6 862.61270.1 20322975
120 3.16 5.63 15.5 27.85 41.93 68.87127.12 209.9 314.5573.7 925.61363.3 21813193
150 3.45 6.14 17.0 30.37 45.72 75.09138.61 228.8 343.0625.5 1009.21486.5 23783481
This formula is the most generally accepted for the flow of steam in pipes. Table 66 is calculated from
this formula and gives the amount of steam passing per [Pg 319] minute that will flow through straight
smooth pipes having a length of 240 diameters from various initial pressures with one pound difference
between the initial and final pressures.
To apply this table for other lengths of pipe and pressure losses other than those assumed, let L = the
length and d the diameter of the pipe, both in inches; l , the loss in pounds; Q, the weight under the
conditions assumed in the table , and Q 1 , the weight for the changed conditions.
For any length of pipe, if the weight of steam passing is the same as given in the table , the loss will be,
L
l = ––––––––– ( 46 )
240 d
If the pipe length is the same as assumed in the table but the loss is different, the quantity of steam
passing per minute will be,
Q1 = Ql½ ( 47 )
For any assumed pipe length and loss of pressure, the weight will be,
240 d l
Q1 = Q ( L )½
––––––––––– ( 48 )
FLOW OF STEAM THROUGH PIPES
Initial
Gauge Diameter [81] of Pipe in Inches, Length of Pipe = 240 Diameters
Pressure
Pounds ¾ 1 1½ 2 2½ 3 4 5 6 8 10 12 15 18
per
Square Weight of Steam per Minute, in Pounds, With One Pound Loss of Pressure
Inch
1 1.16 2.07 5.7 10.27 15.45 25.38 46.85 77.3 115.9 211.4 341.1 502.4 804 1177
10 1.44 2.57 7.1 12.72 19.15 31.45 58.05 95.8 143.6262.0 422.7 622.5 9961458
20 1.70 3.02 8.3 14.94 22.49 36.94 68.20 112.6 168.7307.8 496.5 731.3 1170 1713
30 1.91 3.40 9.4 16.84 25.35 41.63 76.84 126.9 190.1346.8 559.5 824.1 13181930
40 2.10 3.74 10.3 18.51 27.87 45.77 84.49 139.5 209.0381.3 615.3 906.0 14502122
50 2.27 4.04 11.2 20.01 30.13 49.48 91.34 150.8 226.0412.2 665.0 979.5 15672294
60 2.43 4.32 11.9 21.38 32.19 52.87 97.60 161.1 241.5440.5 710.61046.7 16752451
70 2.57 4.58 12.6 22.65 34.10 56.00103.37 170.7 255.8466.5 752.7 1108.5 17742596
80 2.71 4.82 13.3 23.82 35.87 58.91108.74 179.5 269.0490.7 791.7 1166.1 18662731
90 2.83 5.04 13.9 24.92 37.52 61.62 113.74 187.8 281.4513.3 828.11219.8 19512856
100 2.95 5.25 14.5 25.96 39.07 64.18 118.47 195.6 293.1534.6 862.61270.1 20322975
120 3.16 5.63 15.5 27.85 41.93 68.87127.12 209.9 314.5573.7 925.61363.3 21813193
150 3.45 6.14 17.0 30.37 45.72 75.09138.61 228.8 343.0625.5 1009.21486.5 23783481
This formula is the most generally accepted for the flow of steam in pipes. Table 66 is calculated from
this formula and gives the amount of steam passing per [Pg 319] minute that will flow through straight
smooth pipes having a length of 240 diameters from various initial pressures with one pound difference
between the initial and final pressures.
To apply this table for other lengths of pipe and pressure losses other than those assumed, let L = the
length and d the diameter of the pipe, both in inches; l , the loss in pounds; Q, the weight under the
conditions assumed in the table , and Q 1 , the weight for the changed conditions.
For any length of pipe, if the weight of steam passing is the same as given in the table , the loss will be,
L
l = ––––––––– ( 46 )
240 d
If the pipe length is the same as assumed in the table but the loss is different, the quantity of steam
passing per minute will be,
Q1 = Ql½ ( 47 )
For any assumed pipe length and loss of pressure, the weight will be,
240 d l
Q1 = Q ( L )½
––––––––––– ( 48 )
Page 437
TABLE 67
FLOW OF STEAM THROUGH PIPES
LENGTH OF PIPE 1000 FEET
Drop in Pressure in Pounds
Discharge in Pounds per Minute corresponding to per Square Inch corresponding
Drop in Pressure on Right for Pipe Diameters to Discharge on Left: Densities
in Inches in Top Line and corresponding Absolute Pressures
per Square Inch in First Two Lines
Diameter [82] —Discharge Density—Pressure—Drop
12 10 8 6 4 3 2½ 2 1½ 1 .208 .230 .284 .328 .401 .443 .506 .548
Inches Inches Inches Inches Inches Inches Inches Inches Inches Inch 90 100 125 150 180 200 230 250
2328 1443 799 371 123. 55.9 28.8 18.1 6.81 2.52 18.10 16.4 13.3 11.1 9.39 8.50 7.44 6.87
2165 1341 742 344 114.6 51.9 27.6 16.8 6.52 2.34 15.60 14.1 11.4 9.60 8.09 7.33 6.41 5.92
1996 1237 685 318 106.0 47.9 26.4 15.5 6.24 2.16 13.3 12.0 9.74 8.18 6.90 6.24 5.47 5.05
1830 1134 628 292 97.0 43.9 25.2 14.2 5.95 1.98 11.1 10.0 8.13 6.83 5.76 5.21 4.56 4.21
1663 1031 571 265 88.2 39.9 24.0 12.9 5.67 1.80 9.25 8.36 6.78 5.69 4.80 4.34 3.80 3.51
1580 979 542 252 83.8 37.9 22.8 12.3 5.29 1.71 8.33 7.53 6.10 5.13 4.32 3.91 3.42 3.16
1497 928 514 239 79.4 35.9 21.6 11.6 5.00 1.62 7.48 6.76 5.48 4.60 3.88 3.51 3.07 2.84
1414 876 485 226 75.0 33.9 20.4 10.9 4.72 1.53 6.67 6.03 4.88 4.10 3.46 3.13 2.74 2.53
1331 825 457 212 70.6 31.9 19.2 10.3 4.43 1.44 5.91 5.35 4.33 3.64 3.07 2.78 2.43 2.24
1248 873 428 199 66.2 23.9 18.0 9.68 4.15 1.35 5.19 4.69 3.80 3.19 2.69 2.44 2.13 1.97
1164 722 400 186 61.7 27.9 16.8 9.03 3.86 1.26 4.52 4.09 3.31 2.78 2.34 2.12 1.86 1.72
1081 670 371 172 57.3 25.9 15.6 8.38 3.68 1.17 3.90 3.53 2.86 2.40 2.02 1.83 1.60 1.48
998 619 343 159 52.9 23.9 14.4 7.74 3.40 1.08 3.32 3.00 2.43 2.04 1.72 1.56 1.36 1.26
915 567 314 146 48.5 21.9 13.2 7.10 3.11 0.99 2.79 2.52 2.04 1.72 1.45 1.31 1.15 1.06
832 516 286 132 44.1 20.0 12.0 6.45 2.83 0.90 2.31 2.09 1.69 1.42 1.20 1.08 .949 .877
748 464 257 119 39.7 18.0 10.8 5.81 2.55 0.81 1.87 1.69 1.37 1.15 .97 .878 .769 .710
665 412 228 106 35.3 16.0 9.6 5.16 2.26 0.72 1.47 1.33 1.08 .905 .762 .690 .604 .558
582 361 200 92.8 30.9 14.0 8.4 4.52 1.98 0.63 1.13 1.02 .828 .695 .586 .531 .456 .429
To get the pressure drop for lengths other than 1000 feet, multiply by lengths in feet ÷ 1000.
[Pg 320]
Example: Find the weight of steam at 100 pounds initial gauge pressure, which will pass through a 6-
inch pipe 720 feet long with a pressure drop of 4 pounds. Under the conditions assumed in the table ,
293.1 pounds would flow per minute; hence, Q = 293.1, and
240 × 6 × 4
Q 1 = 293.1 ( 720 × 12 ) ½ = 239.9 pounds
–––––––––––––––––––
Table 67 may be frequently found to be of service in problems involving the flow of steam. This table
was calculated by Mr. E. C. Sickles for a pipe 1000 feet long from formula ( 45 ), except that from the
use of a value of the constant K = .0026 instead of .0027, the constant in the formula becomes 87.45
instead of 87.
In using this table , the pressures and densities to be considered, as given at the top of the right-hand
portion, are the mean of the initial and final pressures and densities. Its use is as follows: Assume an
FLOW OF STEAM THROUGH PIPES
LENGTH OF PIPE 1000 FEET
Drop in Pressure in Pounds
Discharge in Pounds per Minute corresponding to per Square Inch corresponding
Drop in Pressure on Right for Pipe Diameters to Discharge on Left: Densities
in Inches in Top Line and corresponding Absolute Pressures
per Square Inch in First Two Lines
Diameter [82] —Discharge Density—Pressure—Drop
12 10 8 6 4 3 2½ 2 1½ 1 .208 .230 .284 .328 .401 .443 .506 .548
Inches Inches Inches Inches Inches Inches Inches Inches Inches Inch 90 100 125 150 180 200 230 250
2328 1443 799 371 123. 55.9 28.8 18.1 6.81 2.52 18.10 16.4 13.3 11.1 9.39 8.50 7.44 6.87
2165 1341 742 344 114.6 51.9 27.6 16.8 6.52 2.34 15.60 14.1 11.4 9.60 8.09 7.33 6.41 5.92
1996 1237 685 318 106.0 47.9 26.4 15.5 6.24 2.16 13.3 12.0 9.74 8.18 6.90 6.24 5.47 5.05
1830 1134 628 292 97.0 43.9 25.2 14.2 5.95 1.98 11.1 10.0 8.13 6.83 5.76 5.21 4.56 4.21
1663 1031 571 265 88.2 39.9 24.0 12.9 5.67 1.80 9.25 8.36 6.78 5.69 4.80 4.34 3.80 3.51
1580 979 542 252 83.8 37.9 22.8 12.3 5.29 1.71 8.33 7.53 6.10 5.13 4.32 3.91 3.42 3.16
1497 928 514 239 79.4 35.9 21.6 11.6 5.00 1.62 7.48 6.76 5.48 4.60 3.88 3.51 3.07 2.84
1414 876 485 226 75.0 33.9 20.4 10.9 4.72 1.53 6.67 6.03 4.88 4.10 3.46 3.13 2.74 2.53
1331 825 457 212 70.6 31.9 19.2 10.3 4.43 1.44 5.91 5.35 4.33 3.64 3.07 2.78 2.43 2.24
1248 873 428 199 66.2 23.9 18.0 9.68 4.15 1.35 5.19 4.69 3.80 3.19 2.69 2.44 2.13 1.97
1164 722 400 186 61.7 27.9 16.8 9.03 3.86 1.26 4.52 4.09 3.31 2.78 2.34 2.12 1.86 1.72
1081 670 371 172 57.3 25.9 15.6 8.38 3.68 1.17 3.90 3.53 2.86 2.40 2.02 1.83 1.60 1.48
998 619 343 159 52.9 23.9 14.4 7.74 3.40 1.08 3.32 3.00 2.43 2.04 1.72 1.56 1.36 1.26
915 567 314 146 48.5 21.9 13.2 7.10 3.11 0.99 2.79 2.52 2.04 1.72 1.45 1.31 1.15 1.06
832 516 286 132 44.1 20.0 12.0 6.45 2.83 0.90 2.31 2.09 1.69 1.42 1.20 1.08 .949 .877
748 464 257 119 39.7 18.0 10.8 5.81 2.55 0.81 1.87 1.69 1.37 1.15 .97 .878 .769 .710
665 412 228 106 35.3 16.0 9.6 5.16 2.26 0.72 1.47 1.33 1.08 .905 .762 .690 .604 .558
582 361 200 92.8 30.9 14.0 8.4 4.52 1.98 0.63 1.13 1.02 .828 .695 .586 .531 .456 .429
To get the pressure drop for lengths other than 1000 feet, multiply by lengths in feet ÷ 1000.
[Pg 320]
Example: Find the weight of steam at 100 pounds initial gauge pressure, which will pass through a 6-
inch pipe 720 feet long with a pressure drop of 4 pounds. Under the conditions assumed in the table ,
293.1 pounds would flow per minute; hence, Q = 293.1, and
240 × 6 × 4
Q 1 = 293.1 ( 720 × 12 ) ½ = 239.9 pounds
–––––––––––––––––––
Table 67 may be frequently found to be of service in problems involving the flow of steam. This table
was calculated by Mr. E. C. Sickles for a pipe 1000 feet long from formula ( 45 ), except that from the
use of a value of the constant K = .0026 instead of .0027, the constant in the formula becomes 87.45
instead of 87.
In using this table , the pressures and densities to be considered, as given at the top of the right-hand
portion, are the mean of the initial and final pressures and densities. Its use is as follows: Assume an
Page 438
allowable drop of pressure through a given length of pipe. From the value as found in the right-hand
column under the column of mean pressure, as determined by the initial and final pressures, pass to the
left-hand portion of the table along the same line until the quantity is found corresponding to the flow
required. The size of the pipe at the head of this column is that which will carry the required amount of
steam with the assumed pressure drop.
The table may be used conversely to determine the pressure drop through a pipe of a given diameter
delivering a specified amount of steam by passing from the known figure in the left to the column on the
right headed by the pressure which is the mean of the initial and final pressures corresponding to the
drop found and the actual initial pressure present.
TABLE 68 For a given flow of steam and
diameter of pipe, the drop in
FLOW OF STEAM INTO THE ATMOSPHERE pressure is proportional to the
Horse Power length and if discharge quantities
Velocity of Actual for other lengths of pipe than
Absolute Discharge per per
Outflow Velocity of 1000 feet are required, they may
Initial Square Inch Square Inch
at Constant Outflow be found by proportion.
Pressure per of Orifice of Orifice if
Density Expanded
Square Inch per Minute Horse Power
Feet per Feet per Elbows, globe valves and a
Pounds Pounds = 30 Pounds
Second Second square-ended entrance to pipes
per Hour
25.37 863 1401 22.81 45.6 all offer resistance to the passage
of steam. It is customary to
30. 867 1408 26.84 53.7
measure the resistance offered by
40. 874 1419 35.18 70.4 such construction in terms of the
50. 880 1429 44.06 88.1 diameter of the pipe. Many
60. 885 1437 52.59 105.2 formulae have been advanced for
70. 889 1444 61.07 122.1 computing the length of pipe in
75. 891 1447 65.30 130.6 diameters equivalent to such
90. 895 1454 77.94 155.9 fittings or valves which offer
100. 898 1459 86.34 172.7 resistance. These formulae,
115. 902 1466 98.76 197.5 however vary widely and for
135. 906 1472 115.61 231.2 ordinary purposes it will be
155. 910 1478 132.21 264.4 sufficiently accurate to allow for
resistance at the entrance of a
165. 912 1481 140.46 280.9
pipe a length equal to 60 times
215. 919 1493 181.58 363.2
the [Pg 321] diameter; for a right
angle elbow, a length equal to 40
diameters, and for a globe valve a length equal to 60 diameters.
The flow of steam of a higher toward a lower pressure increases as the difference in pressure increases to
a point where the external pressure becomes 58 per cent of the absolute initial pressure. Below this point
the flow is neither increased nor decreased by a reduction of the external pressure, even to the extent of a
perfect vacuum. The lowest pressure for which this statement holds when steam is discharged into the
atmosphere is 25.37 pounds. For any pressure below this figure, the atmospheric pressure, 14.7 pounds,
is greater than 58 per cent of the initial pressure. Table 68 , by D. K. Clark, gives the velocity of outflow
at constant density, the actual velocity of outflow expanded (the atmospheric pressure being taken as
14.7 pounds absolute, and the ratio of expansion in the nozzle being 1.624), and the corresponding
discharge per square inch of orifice per minute.
Napier deduced an approximate formula for the outflow of steam into the atmosphere which checks
closely with the figures just given. This formula is:
column under the column of mean pressure, as determined by the initial and final pressures, pass to the
left-hand portion of the table along the same line until the quantity is found corresponding to the flow
required. The size of the pipe at the head of this column is that which will carry the required amount of
steam with the assumed pressure drop.
The table may be used conversely to determine the pressure drop through a pipe of a given diameter
delivering a specified amount of steam by passing from the known figure in the left to the column on the
right headed by the pressure which is the mean of the initial and final pressures corresponding to the
drop found and the actual initial pressure present.
TABLE 68 For a given flow of steam and
diameter of pipe, the drop in
FLOW OF STEAM INTO THE ATMOSPHERE pressure is proportional to the
Horse Power length and if discharge quantities
Velocity of Actual for other lengths of pipe than
Absolute Discharge per per
Outflow Velocity of 1000 feet are required, they may
Initial Square Inch Square Inch
at Constant Outflow be found by proportion.
Pressure per of Orifice of Orifice if
Density Expanded
Square Inch per Minute Horse Power
Feet per Feet per Elbows, globe valves and a
Pounds Pounds = 30 Pounds
Second Second square-ended entrance to pipes
per Hour
25.37 863 1401 22.81 45.6 all offer resistance to the passage
of steam. It is customary to
30. 867 1408 26.84 53.7
measure the resistance offered by
40. 874 1419 35.18 70.4 such construction in terms of the
50. 880 1429 44.06 88.1 diameter of the pipe. Many
60. 885 1437 52.59 105.2 formulae have been advanced for
70. 889 1444 61.07 122.1 computing the length of pipe in
75. 891 1447 65.30 130.6 diameters equivalent to such
90. 895 1454 77.94 155.9 fittings or valves which offer
100. 898 1459 86.34 172.7 resistance. These formulae,
115. 902 1466 98.76 197.5 however vary widely and for
135. 906 1472 115.61 231.2 ordinary purposes it will be
155. 910 1478 132.21 264.4 sufficiently accurate to allow for
resistance at the entrance of a
165. 912 1481 140.46 280.9
pipe a length equal to 60 times
215. 919 1493 181.58 363.2
the [Pg 321] diameter; for a right
angle elbow, a length equal to 40
diameters, and for a globe valve a length equal to 60 diameters.
The flow of steam of a higher toward a lower pressure increases as the difference in pressure increases to
a point where the external pressure becomes 58 per cent of the absolute initial pressure. Below this point
the flow is neither increased nor decreased by a reduction of the external pressure, even to the extent of a
perfect vacuum. The lowest pressure for which this statement holds when steam is discharged into the
atmosphere is 25.37 pounds. For any pressure below this figure, the atmospheric pressure, 14.7 pounds,
is greater than 58 per cent of the initial pressure. Table 68 , by D. K. Clark, gives the velocity of outflow
at constant density, the actual velocity of outflow expanded (the atmospheric pressure being taken as
14.7 pounds absolute, and the ratio of expansion in the nozzle being 1.624), and the corresponding
discharge per square inch of orifice per minute.
Napier deduced an approximate formula for the outflow of steam into the atmosphere which checks
closely with the figures just given. This formula is:
Page 439
pa
W = –––––– ( 49 )
70
Where W = the pounds of steam flowing per second,
p = the absolute pressure in pounds per square inch,
and a = the area of the orifice in square inches.
In some experiments made by Professor C. H. Peabody, in the flow of steam through pipes from ¼ inch
to 1½ inches long and ¼ inch in diameter, with rounded entrances, the greatest difference from Napier’s
formula was 3.2 per cent excess of the experimental over the calculated results.
For steam flowing through an orifice from a higher to a lower pressure where the lower pressure is
greater than 58 per cent of the higher, the flow per minute may be calculated from the formula:
W = 1.9 A K √ (P - d ) d ( 50 )
Where W = the weight of steam discharged in pounds per minute,
A = area of orifice in square inches,
P = the absolute initial pressure in pounds per square inch,
d = the difference in pressure between the two sides in pounds per square inch,
K=
[Pg 322] a constant = .93 for a short pipe, and .63 for a hole in a thin plate or a safety valve.
Vesta Coal Co., California, Pa., Operating at this Plant 3160 Horse Power of Babcock & Wilcox
Boilers
FOOTNOTES
[80] D, the density, is taken as the mean of the density at the initial and final pressures.
W = –––––– ( 49 )
70
Where W = the pounds of steam flowing per second,
p = the absolute pressure in pounds per square inch,
and a = the area of the orifice in square inches.
In some experiments made by Professor C. H. Peabody, in the flow of steam through pipes from ¼ inch
to 1½ inches long and ¼ inch in diameter, with rounded entrances, the greatest difference from Napier’s
formula was 3.2 per cent excess of the experimental over the calculated results.
For steam flowing through an orifice from a higher to a lower pressure where the lower pressure is
greater than 58 per cent of the higher, the flow per minute may be calculated from the formula:
W = 1.9 A K √ (P - d ) d ( 50 )
Where W = the weight of steam discharged in pounds per minute,
A = area of orifice in square inches,
P = the absolute initial pressure in pounds per square inch,
d = the difference in pressure between the two sides in pounds per square inch,
K=
[Pg 322] a constant = .93 for a short pipe, and .63 for a hole in a thin plate or a safety valve.
Vesta Coal Co., California, Pa., Operating at this Plant 3160 Horse Power of Babcock & Wilcox
Boilers
FOOTNOTES
[80] D, the density, is taken as the mean of the density at the initial and final pressures.
Page 440
[81] Diameters up to 5 inches, inclusive, are actual diameters of standard pipe, see Table 62 , page 308 .
[82] Diameters up to 4 inches, inclusive, are actual internal diameters, see Table 62 , page 308 .
[82] Diameters up to 4 inches, inclusive, are actual internal diameters, see Table 62 , page 308 .
Page 441
[Pg 323]
Page 442
HEAT TRANSFER
The rate at which heat is transmitted from a hot gas to a cooler metal surface
over which the gas is flowing has been the subject of a great deal of
investigation both from the experimental and theoretical side. A more or less
complete explanation of this process is necessary for a detailed analysis of
the performance of steam boilers. Such information at the present is almost
entirely lacking and for this reason a boiler, as a physical piece of apparatus,
is not as well understood as it might be. This, however, has had little effect
in its practical development and it is hardly possible that a more complete
understanding of the phenomena discussed will have any radical effect on
the present design.
The amount of heat that is transferred across any surface is usually expressed
as a product, of which one factor is the slope or linear rate of change in
temperature and the other is the amount of heat transferred per unit’s
difference in temperature in unit’s length. In Fourier’s analytical theory of
the conduction of heat, this second factor is taken as a constant and is called
the “conductivity” of the substance. Following this practice, the amount of
heat absorbed by any surface from a hot gas is usually expressed as a
product of the difference in temperature between the gas and the absorbing
surface into a factor which is commonly designated the “transfer rate”. There
has been considerable looseness in the writings of even the best authors as to
the way in which the gas temperature difference is to be measured. If the gas
varies in temperature across the section of the channel through which it is
assumed to flow, and most of them seem to consider that this would be the
case, there are two mean gas temperatures, one the mean of the actual
temperatures at any time across the section, and the other the mean
temperature of the entire volume of the gas passing such a section in any
given time. Since the velocity of flow will of a certainty vary across the
section, this second mean temperature, which is one tacitly assumed in most
instances, may vary materially from the first. The two mean temperatures are
only approximately equal when the actual temperature measured across the
section is very nearly a constant. In what follows it will be assumed that the
mean temperature measured in the second way is referred to. In English
The rate at which heat is transmitted from a hot gas to a cooler metal surface
over which the gas is flowing has been the subject of a great deal of
investigation both from the experimental and theoretical side. A more or less
complete explanation of this process is necessary for a detailed analysis of
the performance of steam boilers. Such information at the present is almost
entirely lacking and for this reason a boiler, as a physical piece of apparatus,
is not as well understood as it might be. This, however, has had little effect
in its practical development and it is hardly possible that a more complete
understanding of the phenomena discussed will have any radical effect on
the present design.
The amount of heat that is transferred across any surface is usually expressed
as a product, of which one factor is the slope or linear rate of change in
temperature and the other is the amount of heat transferred per unit’s
difference in temperature in unit’s length. In Fourier’s analytical theory of
the conduction of heat, this second factor is taken as a constant and is called
the “conductivity” of the substance. Following this practice, the amount of
heat absorbed by any surface from a hot gas is usually expressed as a
product of the difference in temperature between the gas and the absorbing
surface into a factor which is commonly designated the “transfer rate”. There
has been considerable looseness in the writings of even the best authors as to
the way in which the gas temperature difference is to be measured. If the gas
varies in temperature across the section of the channel through which it is
assumed to flow, and most of them seem to consider that this would be the
case, there are two mean gas temperatures, one the mean of the actual
temperatures at any time across the section, and the other the mean
temperature of the entire volume of the gas passing such a section in any
given time. Since the velocity of flow will of a certainty vary across the
section, this second mean temperature, which is one tacitly assumed in most
instances, may vary materially from the first. The two mean temperatures are
only approximately equal when the actual temperature measured across the
section is very nearly a constant. In what follows it will be assumed that the
mean temperature measured in the second way is referred to. In English
Page 443
units the temperature difference is expressed in Fahrenheit degrees and the
transfer rate in B. t. u.’s per hour per square foot of surface. Pecla, who
seems to have been one of the first to consider this subject analytically,
assumed that the transfer rate was constant and independent both of the
temperature differences and the velocity of the gas over the surface.
Rankine, on the other hand, assumed that the transfer rate, while independent
of the velocity of the gas, was proportional to the temperature difference,
and expressed the total amount of heat absorbed as proportional to the square
of the difference in temperature. Neither of these assumptions has any
warrant in either theory or experiment and they are only valuable in so far as
their use determine formulae that fit experimental results. Of the two,
Rankine’s assumption seems to lead to formulae that more nearly represent
actual conditions. It has been quite fully developed by William Kent in his
“Steam Boiler Economy”. Professor Osborne Reynolds, in a short paper
reprinted in Volume I of his “Scientific Papers”, suggests that the transfer
rate is proportional to the product of the density and velocity of the gas and
it is to be assumed that he had in mind the mean velocity, density and
temperature over the section of the channel through which the gas was
assumed to flow. Contrary to [Pg 324] prevalent opinion, Professor Reynolds
gave neither a valid experimental nor a theoretical explanation of his
formula and the attempts that have been made since its first publication to
establish it on any theoretical basis can hardly be considered of scientific
value. Nevertheless, Reynolds’ suggestion was really the starting point of the
scientific investigation of this subject and while his formula cannot in any
sense be held as completely expressing the facts, it is undoubtedly correct to
a first approximation for small temperature differences if the additive
constant, which in his paper he assumed as negligible, is given a value. [83]
Experimental determinations have been made during the last few years of
the heat transfer rate in cylindrical tubes at comparatively low temperatures
and small temperature differences. The results at different velocities have
been plotted and an empirical formula determined expressing the transfer
rate with the velocity as a factor. The exponent of the power of the velocity
appearing in the formula, according to Reynolds, would be unity. The most
probable value, however, deduced from most of the experiments makes it
less than unity. After considering experiments of his own, as well as
experiments of others, Dr. Wilhelm Nusselt [84] concludes that the evidence
supports the following formulae:
transfer rate in B. t. u.’s per hour per square foot of surface. Pecla, who
seems to have been one of the first to consider this subject analytically,
assumed that the transfer rate was constant and independent both of the
temperature differences and the velocity of the gas over the surface.
Rankine, on the other hand, assumed that the transfer rate, while independent
of the velocity of the gas, was proportional to the temperature difference,
and expressed the total amount of heat absorbed as proportional to the square
of the difference in temperature. Neither of these assumptions has any
warrant in either theory or experiment and they are only valuable in so far as
their use determine formulae that fit experimental results. Of the two,
Rankine’s assumption seems to lead to formulae that more nearly represent
actual conditions. It has been quite fully developed by William Kent in his
“Steam Boiler Economy”. Professor Osborne Reynolds, in a short paper
reprinted in Volume I of his “Scientific Papers”, suggests that the transfer
rate is proportional to the product of the density and velocity of the gas and
it is to be assumed that he had in mind the mean velocity, density and
temperature over the section of the channel through which the gas was
assumed to flow. Contrary to [Pg 324] prevalent opinion, Professor Reynolds
gave neither a valid experimental nor a theoretical explanation of his
formula and the attempts that have been made since its first publication to
establish it on any theoretical basis can hardly be considered of scientific
value. Nevertheless, Reynolds’ suggestion was really the starting point of the
scientific investigation of this subject and while his formula cannot in any
sense be held as completely expressing the facts, it is undoubtedly correct to
a first approximation for small temperature differences if the additive
constant, which in his paper he assumed as negligible, is given a value. [83]
Experimental determinations have been made during the last few years of
the heat transfer rate in cylindrical tubes at comparatively low temperatures
and small temperature differences. The results at different velocities have
been plotted and an empirical formula determined expressing the transfer
rate with the velocity as a factor. The exponent of the power of the velocity
appearing in the formula, according to Reynolds, would be unity. The most
probable value, however, deduced from most of the experiments makes it
less than unity. After considering experiments of his own, as well as
experiments of others, Dr. Wilhelm Nusselt [84] concludes that the evidence
supports the following formulae:
Page 444
λw w c pδ
(
a = b ––––––– ––––––––––– u
d 1- u λ
)
Where a is the transfer rate in calories per hour per square meter of surface
per degree centigrade difference in temperature,
u is a physical constant equal to .786 from Dr. Nusselt’s experiments,
b is a constant which, for the units given below, is 15.90,
w is the mean velocity of the gas in meters per second,
c p is the specific heat of the gas at its mean temperature and pressure
in calories per kilogram,
δ is the density in kilograms per cubic meter,
λ is the conductivity at the mean temperature and pressure in calories
per hour per square meter per degree centigrade temperature drop
per meter,
λ w is the conductivity of the steam at the temperature of the tube wall,
d is the diameter of the tube in meters.
If the unit of time for the velocity is made the hour, and in the place of the
product of the velocity and density is written its equivalent, the weight of gas
flowing per hour divided by the area of the tube, this equation becomes:
λw wcp
a = .0255 –––––––
d .214
( Aλ )
–––––––
.786
where the quantities are in the units mentioned, or, since the constants are
absolute constants, in English units,
a is the transfer rate in B. t. u. per hour per square foot of surface per
degree difference in temperature,
W is the weight in pounds of the gas flowing through the tube per hour,
A is the area of the tube in square feet,
d is the diameter of the tube in feet,
cp is the specific heat of the gas at constant pressure,
(
a = b ––––––– ––––––––––– u
d 1- u λ
)
Where a is the transfer rate in calories per hour per square meter of surface
per degree centigrade difference in temperature,
u is a physical constant equal to .786 from Dr. Nusselt’s experiments,
b is a constant which, for the units given below, is 15.90,
w is the mean velocity of the gas in meters per second,
c p is the specific heat of the gas at its mean temperature and pressure
in calories per kilogram,
δ is the density in kilograms per cubic meter,
λ is the conductivity at the mean temperature and pressure in calories
per hour per square meter per degree centigrade temperature drop
per meter,
λ w is the conductivity of the steam at the temperature of the tube wall,
d is the diameter of the tube in meters.
If the unit of time for the velocity is made the hour, and in the place of the
product of the velocity and density is written its equivalent, the weight of gas
flowing per hour divided by the area of the tube, this equation becomes:
λw wcp
a = .0255 –––––––
d .214
( Aλ )
–––––––
.786
where the quantities are in the units mentioned, or, since the constants are
absolute constants, in English units,
a is the transfer rate in B. t. u. per hour per square foot of surface per
degree difference in temperature,
W is the weight in pounds of the gas flowing through the tube per hour,
A is the area of the tube in square feet,
d is the diameter of the tube in feet,
cp is the specific heat of the gas at constant pressure,
Page 445
λ is the conductivity of the gas at the mean temperature and pressure
[Pg 325] in B. t. u. per hour per square foot of surface per degree Fahrenheit
drop in temperature per foot,
λw is the conductivity of the steam at the temperature of the wall of the
tube.
The conductivities of air, carbonic acid gas and superheated steam, as
affected by the temperature, in English units, are:
Conductivity of air .0122 (1 + .00132 T)
Conductivity of carbonic acid gas .0076 (1 + .00229 T)
Conductivity of superheated steam .0119 (1 + .00261 T)
where T is the temperature in degrees Fahrenheit.
Nusselt’s formulae can be taken as typical of the number of other formulae
proposed by German, French and English writers. [85] Physical properties, in
addition to the density, are introduced in the form of coefficients from a
consideration of the physical dimensions of the various units and of the
theoretical formulae that are supposed to govern the flow of the gas and the
transfer of heat. All assume that the correct method of representing the heat
transfer rate is by the use of one term, which seems to be unwarranted and
probably has been adopted on account of the convenience in working up the
results by plotting them logarithmically. This was the method Professor
Reynolds used in determining his equation for the loss in head in fluids
flowing through cylindrical pipes and it is now known that the derived
equation cannot be considered as anything more than an empirical formula.
It, therefore, is well for anyone considering this subject to understand at the
outset that the formulae discussed are only of an empirical nature and
applicable to limited ranges of temperature under the conditions
approximately the same as those surrounding the experiments from which
the constants of the formula were determined.
It is not probable that the subject of heat transfer in boilers will ever be on
any other than an experimental basis until the mathematical expression
connecting the quantity of fluid which will flow through a channel of any
section under a given head has been found and some explanation of its
[Pg 325] in B. t. u. per hour per square foot of surface per degree Fahrenheit
drop in temperature per foot,
λw is the conductivity of the steam at the temperature of the wall of the
tube.
The conductivities of air, carbonic acid gas and superheated steam, as
affected by the temperature, in English units, are:
Conductivity of air .0122 (1 + .00132 T)
Conductivity of carbonic acid gas .0076 (1 + .00229 T)
Conductivity of superheated steam .0119 (1 + .00261 T)
where T is the temperature in degrees Fahrenheit.
Nusselt’s formulae can be taken as typical of the number of other formulae
proposed by German, French and English writers. [85] Physical properties, in
addition to the density, are introduced in the form of coefficients from a
consideration of the physical dimensions of the various units and of the
theoretical formulae that are supposed to govern the flow of the gas and the
transfer of heat. All assume that the correct method of representing the heat
transfer rate is by the use of one term, which seems to be unwarranted and
probably has been adopted on account of the convenience in working up the
results by plotting them logarithmically. This was the method Professor
Reynolds used in determining his equation for the loss in head in fluids
flowing through cylindrical pipes and it is now known that the derived
equation cannot be considered as anything more than an empirical formula.
It, therefore, is well for anyone considering this subject to understand at the
outset that the formulae discussed are only of an empirical nature and
applicable to limited ranges of temperature under the conditions
approximately the same as those surrounding the experiments from which
the constants of the formula were determined.
It is not probable that the subject of heat transfer in boilers will ever be on
any other than an experimental basis until the mathematical expression
connecting the quantity of fluid which will flow through a channel of any
section under a given head has been found and some explanation of its
Page 446
derivation obtained. Taking the simplest possible section, namely, a circle, it
is found that at low velocities the loss of head is directly proportional to the
velocity and the fluid flows in straight stream lines or the motion is direct.
This motion is in exact accordance with the theoretical equations of the
motion of a viscous fluid and constitutes almost a direct proof that the
fundamental assumptions on which these equations are based are correct.
When, however, the velocity exceeds a value which is determinable for any
size of tube, the direct or stream line motion breaks down and is replaced by
an eddy or mixing flow. In this flow the head loss by friction is
approximately, although not exactly, proportional to the square of the
velocity. No explanation of this has ever been found in spite of the fact that
the subject has been treated by the best mathematicians and physicists for
years back. It is to be assumed that the heat transferred during the mixing
flow would be at a much higher rate than with the direct or stream line flow,
and Professors Croker and Clement [86] have demonstrated that this is true,
the increase in the transfer being so [Pg 326] marked as to enable them to
determine the point of critical velocity from observing the rise in
temperature of water flowing through a tube surrounded by a steam jacket.
The formulae given apply only to a mixing flow and inasmuch as, from what
has just been stated, this form of motion does not exist from zero velocity
upward, it follows that any expression for the heat transfer rate that would
make its value zero when the velocity is zero, can hardly be correct. Below
the critical velocity, the transfer rate seems to be little affected by change in
velocity and Nusselt, [87] in another paper which mathematically treats the
direct or stream line flow, concludes that, while it is approximately constant
as far as the velocity is concerned in a straight cylindrical tube, it would vary
from point to point of the tube, growing less as the surface passed over
increased.
It should further be noted that no account in any of this experimental work
has been taken of radiation of heat from the gas. Since the common gases
absorb very little radiant heat at ordinary temperatures, it has been assumed
that they radiate very little at any temperature. This may or may not be true,
but certainly a visible flame must radiate as well as absorb heat. However
this radiation may occur, since it would be a volume phenomenon rather than
a surface phenomenon it would be considered somewhat differently from
ordinary radiation. It might apply as increasing the conductivity of the gas
is found that at low velocities the loss of head is directly proportional to the
velocity and the fluid flows in straight stream lines or the motion is direct.
This motion is in exact accordance with the theoretical equations of the
motion of a viscous fluid and constitutes almost a direct proof that the
fundamental assumptions on which these equations are based are correct.
When, however, the velocity exceeds a value which is determinable for any
size of tube, the direct or stream line motion breaks down and is replaced by
an eddy or mixing flow. In this flow the head loss by friction is
approximately, although not exactly, proportional to the square of the
velocity. No explanation of this has ever been found in spite of the fact that
the subject has been treated by the best mathematicians and physicists for
years back. It is to be assumed that the heat transferred during the mixing
flow would be at a much higher rate than with the direct or stream line flow,
and Professors Croker and Clement [86] have demonstrated that this is true,
the increase in the transfer being so [Pg 326] marked as to enable them to
determine the point of critical velocity from observing the rise in
temperature of water flowing through a tube surrounded by a steam jacket.
The formulae given apply only to a mixing flow and inasmuch as, from what
has just been stated, this form of motion does not exist from zero velocity
upward, it follows that any expression for the heat transfer rate that would
make its value zero when the velocity is zero, can hardly be correct. Below
the critical velocity, the transfer rate seems to be little affected by change in
velocity and Nusselt, [87] in another paper which mathematically treats the
direct or stream line flow, concludes that, while it is approximately constant
as far as the velocity is concerned in a straight cylindrical tube, it would vary
from point to point of the tube, growing less as the surface passed over
increased.
It should further be noted that no account in any of this experimental work
has been taken of radiation of heat from the gas. Since the common gases
absorb very little radiant heat at ordinary temperatures, it has been assumed
that they radiate very little at any temperature. This may or may not be true,
but certainly a visible flame must radiate as well as absorb heat. However
this radiation may occur, since it would be a volume phenomenon rather than
a surface phenomenon it would be considered somewhat differently from
ordinary radiation. It might apply as increasing the conductivity of the gas
Page 447
which, however independent of radiation, is known to increase with the
temperature. It is, therefore, to be expected that at high temperatures the rate
of transfer will be greater than at low temperatures. The experimental
determinations of transfer rates at high temperatures are lacking.
Although comparatively nothing is known concerning the heat radiation
from gases at high temperatures, there is no question but what a large
proportion of the heat absorbed by a boiler is received direct as radiation
from the furnace. Experiments show that the lower row of tubes of a
Babcock & Wilcox boiler absorb heat at an average rate per square foot of
surface between the first baffle and the front headers equivalent to the
evaporation of from 50 to 75 pounds of water from and at 212 degrees
Fahrenheit per hour. Inasmuch as in these experiments no separation could
be made between the heat absorbed by the bottom of the tube and that
absorbed by the top, the average includes both maximum and minimum rates
for those particular tubes and it is fair to assume that the portion of the tubes
actually exposed to the furnace radiations absorb heat at a higher rate. Part of
this heat was, of course absorbed by actual contact between the hot gases
and the boiler heating surface. A large portion of it, however, must have been
due to radiation. Whether this radiant heat came from the fire surface and the
brickwork and passed through the gases in the furnace with little or no
absorption, or whether, on the other hand, the radiation were absorbed by the
furnace gases and the heat received by the boiler was a secondary radiation
from the gases themselves and at a rate corresponding to the actual gas
temperature, is a question. If the radiations are direct, then the term “furnace
temperature”, as usually used has no scientific meaning, for obviously the
temperature of the gas in the furnace would be entirely different from the
radiation temperature, even were it possible to attach any significance to the
term “radiation temperature”, and it is not possible to do this unless the
radiations are what are known as “full radiations” from a so-called “black
body”. If furnace radiation takes place in this manner, the indications of a
pyrometer placed in a furnace are hard to interpret and such [Pg 327]
temperature measurements can be of little value. If the furnace gases absorb
the radiations from the fire and from the brickwork of the side walls and in
their turn radiate heat to the boiler surface, it is scientifically correct to
assume that the actual or sensible temperature of the gas would be measured
by a pyrometer and the amount of radiation could be calculated from this
temperature by Stefan’s law, which is to the effect that the rate of radiation is
temperature. It is, therefore, to be expected that at high temperatures the rate
of transfer will be greater than at low temperatures. The experimental
determinations of transfer rates at high temperatures are lacking.
Although comparatively nothing is known concerning the heat radiation
from gases at high temperatures, there is no question but what a large
proportion of the heat absorbed by a boiler is received direct as radiation
from the furnace. Experiments show that the lower row of tubes of a
Babcock & Wilcox boiler absorb heat at an average rate per square foot of
surface between the first baffle and the front headers equivalent to the
evaporation of from 50 to 75 pounds of water from and at 212 degrees
Fahrenheit per hour. Inasmuch as in these experiments no separation could
be made between the heat absorbed by the bottom of the tube and that
absorbed by the top, the average includes both maximum and minimum rates
for those particular tubes and it is fair to assume that the portion of the tubes
actually exposed to the furnace radiations absorb heat at a higher rate. Part of
this heat was, of course absorbed by actual contact between the hot gases
and the boiler heating surface. A large portion of it, however, must have been
due to radiation. Whether this radiant heat came from the fire surface and the
brickwork and passed through the gases in the furnace with little or no
absorption, or whether, on the other hand, the radiation were absorbed by the
furnace gases and the heat received by the boiler was a secondary radiation
from the gases themselves and at a rate corresponding to the actual gas
temperature, is a question. If the radiations are direct, then the term “furnace
temperature”, as usually used has no scientific meaning, for obviously the
temperature of the gas in the furnace would be entirely different from the
radiation temperature, even were it possible to attach any significance to the
term “radiation temperature”, and it is not possible to do this unless the
radiations are what are known as “full radiations” from a so-called “black
body”. If furnace radiation takes place in this manner, the indications of a
pyrometer placed in a furnace are hard to interpret and such [Pg 327]
temperature measurements can be of little value. If the furnace gases absorb
the radiations from the fire and from the brickwork of the side walls and in
their turn radiate heat to the boiler surface, it is scientifically correct to
assume that the actual or sensible temperature of the gas would be measured
by a pyrometer and the amount of radiation could be calculated from this
temperature by Stefan’s law, which is to the effect that the rate of radiation is
Page 448
proportional to the fourth power of the absolute temperature, using the
constant with the resulting formula that has been determined from direct
experiment and other phenomena. With this understanding of the matter, the
radiations absorbed by a boiler can be taken as equal to that absorbed by a
flat surface, covering the portion of the boiler tubes exposed to the furnace
and at the temperature of the tube surface, when completely exposed on one
side to the radiations from an atmosphere at the temperature in the furnace.
With this assumption, if S 1 is the area of the surface, T the absolute
temperature of the furnace gases, t the absolute temperature of the tube
surface of the boiler, the heat absorbed per hour measured in B. t. u.’s is
equal to
T t
1600 (( 1000 ) - ( 1000 ) ) S
––––––––
4 ––––––––
4 1
In using this formula, or in any work connected with heat transfer, the
external temperature of the boiler heating surface can be taken as that of
saturated steam at the pressure under which the boiler is working, with an
almost negligible error, since experiments have shown that with a surface
clean internally, the external surface is only a few degrees hotter than the
water in contact with the inner surface, even at the highest rates of
evaporation. Further than this, it is not conceivable that in a modern boiler
there can be much difference in the temperature of the boiler in the different
parts, or much difference between the temperature of the water and the
temperature of the steam in the drums which is in contact with it.
If the total evaporation of a boiler measured in B. t. u.’s per hour is
represented by E, the furnace temperature by T 1 , the temperature of the gas
leaving the boiler by T 2 , the weight of gas leaving the furnace and passing
through the setting per hour by W, the specific heat of the gas by C, it
follows from the fact that the total amount of heat absorbed is equal to the
heat received from radiation plus the heat removed from the gases by
cooling from the temperature T 1 to the temperature T 2 , that
E = 1600 T - t S 1 + W C (T 1 - T 2 )
(( ––––––––
) (
4 ––––––––
) )
4
constant with the resulting formula that has been determined from direct
experiment and other phenomena. With this understanding of the matter, the
radiations absorbed by a boiler can be taken as equal to that absorbed by a
flat surface, covering the portion of the boiler tubes exposed to the furnace
and at the temperature of the tube surface, when completely exposed on one
side to the radiations from an atmosphere at the temperature in the furnace.
With this assumption, if S 1 is the area of the surface, T the absolute
temperature of the furnace gases, t the absolute temperature of the tube
surface of the boiler, the heat absorbed per hour measured in B. t. u.’s is
equal to
T t
1600 (( 1000 ) - ( 1000 ) ) S
––––––––
4 ––––––––
4 1
In using this formula, or in any work connected with heat transfer, the
external temperature of the boiler heating surface can be taken as that of
saturated steam at the pressure under which the boiler is working, with an
almost negligible error, since experiments have shown that with a surface
clean internally, the external surface is only a few degrees hotter than the
water in contact with the inner surface, even at the highest rates of
evaporation. Further than this, it is not conceivable that in a modern boiler
there can be much difference in the temperature of the boiler in the different
parts, or much difference between the temperature of the water and the
temperature of the steam in the drums which is in contact with it.
If the total evaporation of a boiler measured in B. t. u.’s per hour is
represented by E, the furnace temperature by T 1 , the temperature of the gas
leaving the boiler by T 2 , the weight of gas leaving the furnace and passing
through the setting per hour by W, the specific heat of the gas by C, it
follows from the fact that the total amount of heat absorbed is equal to the
heat received from radiation plus the heat removed from the gases by
cooling from the temperature T 1 to the temperature T 2 , that
E = 1600 T - t S 1 + W C (T 1 - T 2 )
(( ––––––––
) (
4 ––––––––
) )
4
Page 449
1000 1000
This formula can be used for calculating the furnace temperature when E, t
and T 2 are known but it must be remembered that an assumption which is
probably, in part at least, incorrect is implied in using it or in using any
similar formula. Expressed in this way, however, it seems more rational than
the one proposed a few years ago by Dr. Nicholson [88] where, in place of the
surface exposed to radiation, he uses the grate surface and assumes the
furnace gas temperature as equal to the fire temperature.
If the heat transfer rate is taken as independent of the gas temperature and
the heat absorbed by an element of the surface in a given time is equated to
the heat given out from the gas passing over this surface in the same time, a
single integration gives
(T - t ) = (T 1 - t ) e - R s ⁄ W C
[Pg 328]
where s is the area of surface passed over by the gases from the furnace to
any point where the gas temperature T is measured, and the rate of heat
transfer is R. As written, this formula could be used for calculating the
temperature of the gas at any point in the boiler setting. Gas temperatures,
however, calculated in this way are not to be depended upon as it is known
that the transfer rate is not independent of the temperature. Again, if the
transfer rate is assumed as varying directly with the weight of the gases
passing, which is Reynolds’ suggestion, it is seen that the weight of the gases
entirely disappears from the formula and as a consequence if the formula
was correct, as long as the temperature of the gas entering the surface from
the furnace was the same, the temperatures throughout the setting would be
the same. This is known also to be incorrect. If, however, in place of T is
written T 2 and in place of s is written S, the entire surface of the boiler, and
the formula is re-arranged, it becomes:
WC T1-t
(
R = –––––––– Log [89] ––––––––––
S T2-t
)
This formula can be used for calculating the furnace temperature when E, t
and T 2 are known but it must be remembered that an assumption which is
probably, in part at least, incorrect is implied in using it or in using any
similar formula. Expressed in this way, however, it seems more rational than
the one proposed a few years ago by Dr. Nicholson [88] where, in place of the
surface exposed to radiation, he uses the grate surface and assumes the
furnace gas temperature as equal to the fire temperature.
If the heat transfer rate is taken as independent of the gas temperature and
the heat absorbed by an element of the surface in a given time is equated to
the heat given out from the gas passing over this surface in the same time, a
single integration gives
(T - t ) = (T 1 - t ) e - R s ⁄ W C
[Pg 328]
where s is the area of surface passed over by the gases from the furnace to
any point where the gas temperature T is measured, and the rate of heat
transfer is R. As written, this formula could be used for calculating the
temperature of the gas at any point in the boiler setting. Gas temperatures,
however, calculated in this way are not to be depended upon as it is known
that the transfer rate is not independent of the temperature. Again, if the
transfer rate is assumed as varying directly with the weight of the gases
passing, which is Reynolds’ suggestion, it is seen that the weight of the gases
entirely disappears from the formula and as a consequence if the formula
was correct, as long as the temperature of the gas entering the surface from
the furnace was the same, the temperatures throughout the setting would be
the same. This is known also to be incorrect. If, however, in place of T is
written T 2 and in place of s is written S, the entire surface of the boiler, and
the formula is re-arranged, it becomes:
WC T1-t
(
R = –––––––– Log [89] ––––––––––
S T2-t
)
Page 450
This formula can be considered as giving a way of calculating an average
transfer rate. It has been used in this way for calculating the average transfer
rate from boiler tests in which the capacity has varied from an evaporation of
a little over 3 pounds per square foot of surface up to 15 pounds. When
plotted against the gas weights, it was found that the points were almost
exactly on a line. This line, however, did not pass through the zero point but
started at a point corresponding to approximately a transfer rate of 2.
Checked out against many other tests, the straight line law seems to hold
generally and this is true even though material changes are made in the
method of calculating the furnace temperature. The inclination of the line,
however, varied inversely as the average area for the passage of the gas
through the boiler. If A is the average area between all the passes of the
boiler, the heat transfer rate in Babcock & Wilcox type boilers with ordinary
clean surfaces can be determined to a rather close approximation from the
formula:
W
R = 2.00 + .0014 ––
A
The manner in which A appears in this formula is the same as it would
appear in any formula in which the heat transfer rate was taken as depending
upon the product of the velocity and the density of the gas jointly, since this
product, as pointed out above, is equivalent to W/A. Nusselt’s experiments,
as well as those of others, indicate that the ratio appears in the proper way.
While the underlying principles from which the formula for this average
transfer rate was determined are questionable and at best only approximately
correct, it nevertheless follows that assuming the transfer rate as determined
experimentally, the formula can be used in an inverse way for calculating the
amount of surface required in a boiler for cooling the gases through a range
of temperature covered by the experiments and it has been found that the
results bear out this assumption. The practical application of the theory of
heat transfer, as developed at present, seems consequently to rest on these
last two formulae, which from their nature are more or less empirical.
Through the range in the production of steam met with in boilers now in
service which in the marine type extends to the average evaporation of 12 to
transfer rate. It has been used in this way for calculating the average transfer
rate from boiler tests in which the capacity has varied from an evaporation of
a little over 3 pounds per square foot of surface up to 15 pounds. When
plotted against the gas weights, it was found that the points were almost
exactly on a line. This line, however, did not pass through the zero point but
started at a point corresponding to approximately a transfer rate of 2.
Checked out against many other tests, the straight line law seems to hold
generally and this is true even though material changes are made in the
method of calculating the furnace temperature. The inclination of the line,
however, varied inversely as the average area for the passage of the gas
through the boiler. If A is the average area between all the passes of the
boiler, the heat transfer rate in Babcock & Wilcox type boilers with ordinary
clean surfaces can be determined to a rather close approximation from the
formula:
W
R = 2.00 + .0014 ––
A
The manner in which A appears in this formula is the same as it would
appear in any formula in which the heat transfer rate was taken as depending
upon the product of the velocity and the density of the gas jointly, since this
product, as pointed out above, is equivalent to W/A. Nusselt’s experiments,
as well as those of others, indicate that the ratio appears in the proper way.
While the underlying principles from which the formula for this average
transfer rate was determined are questionable and at best only approximately
correct, it nevertheless follows that assuming the transfer rate as determined
experimentally, the formula can be used in an inverse way for calculating the
amount of surface required in a boiler for cooling the gases through a range
of temperature covered by the experiments and it has been found that the
results bear out this assumption. The practical application of the theory of
heat transfer, as developed at present, seems consequently to rest on these
last two formulae, which from their nature are more or less empirical.
Through the range in the production of steam met with in boilers now in
service which in the marine type extends to the average evaporation of 12 to
Page 451
15 pounds of water from and at 212 degrees Fahrenheit per square foot of
surface, the constant 2 [Pg 329] in the approximate formula for the average
heat transfer rate constitutes quite a large proportion of the total. The
comparative increase in the transfer rate due to a change in weight of the
gases is not as great consequently as it would be if this constant were zero.
For this reason, with the same temperature of the gases entering the boiler
surface, there will be a gradual increase in the temperature of the gases
leaving the surface as the velocity or weight of flow increases and the
proportion of the heat contained in the gases entering the boiler which is
absorbed by it is gradually reduced. It is, of course, possible that the weight
of the gases could be increased to such an amount or the area for their
passage through the boiler reduced by additional baffles until the constant
term in the heat transfer formula would be relatively unimportant. Under
such conditions, as pointed out previously, the final gas temperature would
be unaffected by a further increase in the velocity of the flow and the
fraction of the heat carried by the gases removed by the boiler would be
constant. Actual tests of waste heat boilers in which the weight of gas per
square foot of sectional area for its passage is many times more than in
ordinary installations show, however, that this condition has not been
attained and it will probably never be attained in any practical installation. It
is for this reason that the conclusions of Dr. Nicholson in the paper referred
to and of Messrs. Kreisinger and Ray in the pamphlet “The Transmission of
Heat into Steam Boilers”, published by the Department of the Interior in
1912, are not applicable without modification to boiler design.
In superheaters the heat transfer is effected in two different stages; the first
transfer is from the hot gas to the metal of the superheater tube and the
second transfer is from the metal of the tube to the steam on the inside.
There is, theoretically, an intermediate stage in the transfer of the heat from
the outside to the inside surface of the tube. The conductivity of steel is
sufficient, however, to keep the temperatures of the two sides of the tube
very nearly equal to each other so that the effect of the transfer in the tube
itself can be neglected. The transfer from the hot gas to the metal of the tube
takes place in the same way as with the boiler tubes proper, regard being
paid to the temperature of the tube which increases as the steam is heated.
The transfer from the inside surface of the tube to the steam is the inverse of
the process of the transfer of the heat on the outside and seems to follow the
same laws. The transfer rate, therefore, will increase with the velocity of the
surface, the constant 2 [Pg 329] in the approximate formula for the average
heat transfer rate constitutes quite a large proportion of the total. The
comparative increase in the transfer rate due to a change in weight of the
gases is not as great consequently as it would be if this constant were zero.
For this reason, with the same temperature of the gases entering the boiler
surface, there will be a gradual increase in the temperature of the gases
leaving the surface as the velocity or weight of flow increases and the
proportion of the heat contained in the gases entering the boiler which is
absorbed by it is gradually reduced. It is, of course, possible that the weight
of the gases could be increased to such an amount or the area for their
passage through the boiler reduced by additional baffles until the constant
term in the heat transfer formula would be relatively unimportant. Under
such conditions, as pointed out previously, the final gas temperature would
be unaffected by a further increase in the velocity of the flow and the
fraction of the heat carried by the gases removed by the boiler would be
constant. Actual tests of waste heat boilers in which the weight of gas per
square foot of sectional area for its passage is many times more than in
ordinary installations show, however, that this condition has not been
attained and it will probably never be attained in any practical installation. It
is for this reason that the conclusions of Dr. Nicholson in the paper referred
to and of Messrs. Kreisinger and Ray in the pamphlet “The Transmission of
Heat into Steam Boilers”, published by the Department of the Interior in
1912, are not applicable without modification to boiler design.
In superheaters the heat transfer is effected in two different stages; the first
transfer is from the hot gas to the metal of the superheater tube and the
second transfer is from the metal of the tube to the steam on the inside.
There is, theoretically, an intermediate stage in the transfer of the heat from
the outside to the inside surface of the tube. The conductivity of steel is
sufficient, however, to keep the temperatures of the two sides of the tube
very nearly equal to each other so that the effect of the transfer in the tube
itself can be neglected. The transfer from the hot gas to the metal of the tube
takes place in the same way as with the boiler tubes proper, regard being
paid to the temperature of the tube which increases as the steam is heated.
The transfer from the inside surface of the tube to the steam is the inverse of
the process of the transfer of the heat on the outside and seems to follow the
same laws. The transfer rate, therefore, will increase with the velocity of the
Page 452
steam through the tube. For this reason, internal cores are quite often used in
superheaters and actually result in an increase in the amount of superheat
obtained from a given surface. The average transfer rate in superheaters
based on a difference in mean temperature between the gas on the outside of
the tubes and the steam on the inside of the tubes is if R is the transfer rate
from the gas to the tube and r the rate from the tube to the steam:
Rr
–––––––––
R+r
and is always less than either R or r . This rate is usually greater than the
average transfer rate for the boiler as computed in the way outlined in the
preceding paragraphs. Since, however, steam cannot, under any imagined set
of conditions, take up more heat from a tube than would water at the same
average temperature, this fact supports the contention made that the actual
transfer rate in a boiler must increase quite rapidly with the temperatures.
The actual transfer rates in superheaters are affected by so many conditions
that it has not so far been possible to evolve any formula of practical value.
[Pg 330]
superheaters and actually result in an increase in the amount of superheat
obtained from a given surface. The average transfer rate in superheaters
based on a difference in mean temperature between the gas on the outside of
the tubes and the steam on the inside of the tubes is if R is the transfer rate
from the gas to the tube and r the rate from the tube to the steam:
Rr
–––––––––
R+r
and is always less than either R or r . This rate is usually greater than the
average transfer rate for the boiler as computed in the way outlined in the
preceding paragraphs. Since, however, steam cannot, under any imagined set
of conditions, take up more heat from a tube than would water at the same
average temperature, this fact supports the contention made that the actual
transfer rate in a boiler must increase quite rapidly with the temperatures.
The actual transfer rates in superheaters are affected by so many conditions
that it has not so far been possible to evolve any formula of practical value.
[Pg 330]
Page 453
Iron City Brewery of the Pittsburgh Brewing Co., Pittsburgh, Pa,
Operating in this Plant 2000 Horse Power of Babcock & Wilcox Boilers
FOOTNOTES
[83] H. P. Jordan, “Proceedings of the Institute of Mechanical Engineers”, 1909.
[84] “Zeitschrift des Vereines Deutscher Ingenieur”, 1909, page 1750.
[85] Heinrich Gröber—Zeit. d. Ver. Ing., March 1912, December 1912. Leprince-
Ringuet—Revue de Mecanique. July 1911. John Perry—“The Steam Engine”. T.
E. Stanton—Philosophical Transactions, 1897. Dr. J. T. Nicholson—Proceedings
Institute of Engineers & Shipbuilders in Scotland, 1910. W. E. Dally—
Proceedings Institute of Mechanical Engineers, 1909.
[86] Proceedings Royal Society, Vol. LXXI.
[87] Zeitschrift des Vereines Deutscher Ingenieur, 1910, page 1154.
[88] Proceedings Institute of Engineers and Shipbuilders, 1910.
[89] Natural or Hyperbolic Logarithm.
Operating in this Plant 2000 Horse Power of Babcock & Wilcox Boilers
FOOTNOTES
[83] H. P. Jordan, “Proceedings of the Institute of Mechanical Engineers”, 1909.
[84] “Zeitschrift des Vereines Deutscher Ingenieur”, 1909, page 1750.
[85] Heinrich Gröber—Zeit. d. Ver. Ing., March 1912, December 1912. Leprince-
Ringuet—Revue de Mecanique. July 1911. John Perry—“The Steam Engine”. T.
E. Stanton—Philosophical Transactions, 1897. Dr. J. T. Nicholson—Proceedings
Institute of Engineers & Shipbuilders in Scotland, 1910. W. E. Dally—
Proceedings Institute of Mechanical Engineers, 1909.
[86] Proceedings Royal Society, Vol. LXXI.
[87] Zeitschrift des Vereines Deutscher Ingenieur, 1910, page 1154.
[88] Proceedings Institute of Engineers and Shipbuilders, 1910.
[89] Natural or Hyperbolic Logarithm.
Page 454
[Pg 331]
Page 455
INDEX
PAGE
Absolute pressure 117
Absolute zero 80
Accessibility of Babcock & Wilcox boiler 59
Acidity in boiler feed water 106
Actual evap. corresponding to boiler horse power 288
Advantages of Babcock & Wilcox boilers 61
Stoker firing 195
Water tube over fire tube boilers 61
Air, composition of 147
In boiler feed water 106
Properties of 147
Required for combustion 152 , 156
Specific heat of 148
Supplied for combustion 157
Vapor in 149
Volume of 147
Weight of 147
Alkalinity in boiler feed water 103
Testing feed for 103
Altitude, boiling point of water at 97
Chimney sizes corrected for 248
Alum in feed water treatment 106
A. S. M. E. code for boiler testing 267
Analyses, comparison of proximate and ultimate 183
Proximate coal, and heating values 177
Analysis, coal, proximate, methods of 176
PAGE
Absolute pressure 117
Absolute zero 80
Accessibility of Babcock & Wilcox boiler 59
Acidity in boiler feed water 106
Actual evap. corresponding to boiler horse power 288
Advantages of Babcock & Wilcox boilers 61
Stoker firing 195
Water tube over fire tube boilers 61
Air, composition of 147
In boiler feed water 106
Properties of 147
Required for combustion 152 , 156
Specific heat of 148
Supplied for combustion 157
Vapor in 149
Volume of 147
Weight of 147
Alkalinity in boiler feed water 103
Testing feed for 103
Altitude, boiling point of water at 97
Chimney sizes corrected for 248
Alum in feed water treatment 106
A. S. M. E. code for boiler testing 267
Analyses, comparison of proximate and ultimate 183
Proximate coal, and heating values 177
Analysis, coal, proximate, methods of 176
Page 456
Coal, ultimate 173
Determination of heating value from 173
Analysis, Flue gas 155
Flue gas, methods of 160
Flue gas, object of 155
Anthracite coal 166
Combustion rates with 246
Distribution of 167
Draft required for 246
Firing 190
Grate ratio for 191
Semi 166
Sizes of 190
Steam as aid to burning 191
Thickness of fires with 191
Arches, fire brick, as aid to combustion 190
Fire brick, for 304
Fire brick, laying 305
Automatic stokers, advantages of 195
Overfeed 196
Traveling grate 197
Traveling grate, Babcock & Wilcox 194
Underfeed 196
Auxiliaries, exhaust from, in heating feed water 113
Superheated steam with 142
Auxiliary grates, with blast furnace gas 228
With oil fuel 225
With waste heat 235
Babcock, G. H., lecture on circulation of water in Boilers 28
Lecture on theory of steam making 92
Babcock & Wilcox Co., Works at Barberton, Ohio 7
Works at Bayonne, N. J. 6
Determination of heating value from 173
Analysis, Flue gas 155
Flue gas, methods of 160
Flue gas, object of 155
Anthracite coal 166
Combustion rates with 246
Distribution of 167
Draft required for 246
Firing 190
Grate ratio for 191
Semi 166
Sizes of 190
Steam as aid to burning 191
Thickness of fires with 191
Arches, fire brick, as aid to combustion 190
Fire brick, for 304
Fire brick, laying 305
Automatic stokers, advantages of 195
Overfeed 196
Traveling grate 197
Traveling grate, Babcock & Wilcox 194
Underfeed 196
Auxiliaries, exhaust from, in heating feed water 113
Superheated steam with 142
Auxiliary grates, with blast furnace gas 228
With oil fuel 225
With waste heat 235
Babcock, G. H., lecture on circulation of water in Boilers 28
Lecture on theory of steam making 92
Babcock & Wilcox Co., Works at Barberton, Ohio 7
Works at Bayonne, N. J. 6
Page 457
Babcock & Wilcox boiler, accessibility of 59
Advantages of 61
Circulation of water in 57 , 66
Construction of 49
Cross boxes 50
Cross drum 53
Cross drum, dry steam with 71
Drumheads 49
Drums 49
Durability 75
Evolution of 39
Fittings 55
Fixtures 55
Fronts 53
Handhole fittings 50 , 51
Headers 50 , 51
Inclined header, wrought steel 54
Inspection 75
Life of 76
Materials entering into the construction of 59
Mud drums 51
Path of gases in 57
Path of water in 57
Rear tube doors of 53 , 74
Repairs 75
Safety of 66
Sections 50
Set for utilizing waste heat 236
Set with Babcock & Wilcox chain grate stoker 12
Set with bagasse furnace 208
Set with Peabody oil furnace 222
Supports, cross drum 53
Advantages of 61
Circulation of water in 57 , 66
Construction of 49
Cross boxes 50
Cross drum 53
Cross drum, dry steam with 71
Drumheads 49
Drums 49
Durability 75
Evolution of 39
Fittings 55
Fixtures 55
Fronts 53
Handhole fittings 50 , 51
Headers 50 , 51
Inclined header, wrought steel 54
Inspection 75
Life of 76
Materials entering into the construction of 59
Mud drums 51
Path of gases in 57
Path of water in 57
Rear tube doors of 53 , 74
Repairs 75
Safety of 66
Sections 50
Set for utilizing waste heat 236
Set with Babcock & Wilcox chain grate stoker 12
Set with bagasse furnace 208
Set with Peabody oil furnace 222
Supports, cross drum 53
Page 458
Supports, longitudinal drum 52
Tube doors 53
Vertical header, cast iron 58
Vertical header, wrought steel 48
Babcock & Wilcox chain grate stoker 194
Babcock & Wilcox superheater 136
Bagasse, composition of 206
Furnace 209
Heat, value of 206
Tests of Babcock & Wilcox boilers with 210
Value of diffusion 207
Barium carbonate in feed water treatment 106
Barium hydrate in feed water treatment 106
Barrus draft gauge 254
Bituminous coal, classification of 167
Combustion rates with 246
Composition of 177
Distribution of 168
Firing methods 193
Semi 166
Sizes of 191
Thickness of fire with 193
Blast furnace gas, burners for 228
Combustion of 228
Composition of 227
Stacks for 228
Boiler, Blakey’s 23
Brickwork, care of 307
Circulation of water in steam 28
Compounds 109
Development of water tube 23
Eve’s 24
Tube doors 53
Vertical header, cast iron 58
Vertical header, wrought steel 48
Babcock & Wilcox chain grate stoker 194
Babcock & Wilcox superheater 136
Bagasse, composition of 206
Furnace 209
Heat, value of 206
Tests of Babcock & Wilcox boilers with 210
Value of diffusion 207
Barium carbonate in feed water treatment 106
Barium hydrate in feed water treatment 106
Barrus draft gauge 254
Bituminous coal, classification of 167
Combustion rates with 246
Composition of 177
Distribution of 168
Firing methods 193
Semi 166
Sizes of 191
Thickness of fire with 193
Blast furnace gas, burners for 228
Combustion of 228
Composition of 227
Stacks for 228
Boiler, Blakey’s 23
Brickwork, care of 307
Circulation of water in steam 28
Compounds 109
Development of water tube 23
Eve’s 24
Page 459
Evolution of Babcock & Wilcox 39
Fire tube, compared with water tube 61
Guerney’s 24
Horse power 263
Loads, economical 283
Perkins’ 24
Room piping 108
Room practice 297
Rumsey’s 23
Stevens’, John 23
Stevens’, John Cox 23
Units, number of 289
Units, size of 289
Wilcox’s 25
Woolf’s 23
Boilers, capacity of 278
Care of 291
Efficiency of 256
Horse power of 265
Operation of 291
Requirements of steam 27
Testing 267
Boiling point 86
Of various substances 86
Of water as affected by altitude 97
Brick, fire 304
Arches 305
Classification of 304
Compression of 303
Expansion of 303
Hardness of 303
Laying up 305 [Pg 332]
Fire tube, compared with water tube 61
Guerney’s 24
Horse power 263
Loads, economical 283
Perkins’ 24
Room piping 108
Room practice 297
Rumsey’s 23
Stevens’, John 23
Stevens’, John Cox 23
Units, number of 289
Units, size of 289
Wilcox’s 25
Woolf’s 23
Boilers, capacity of 278
Care of 291
Efficiency of 256
Horse power of 265
Operation of 291
Requirements of steam 27
Testing 267
Boiling point 86
Of various substances 86
Of water as affected by altitude 97
Brick, fire 304
Arches 305
Classification of 304
Compression of 303
Expansion of 303
Hardness of 303
Laying up 305 [Pg 332]
Page 460
Nodules, ratio of 303
Nodules, size of 303
Plasticity of 302
Brick, red 302
Brickwork, care of 307
British thermal unit 83
Burners , blast furnace gas 228
By-product coke oven gas 231
Natural gas 231
Oil 217
Oil, capacity of 221
Oil, mechanical atomizing 219
Oil, operation of 223
Oil, steam atomizing 218
Oil, steam consumption of 220
Burning hydrogen, loss due to moisture formed in 261
By-product coke oven gas burners 231
By-product coke oven gas, combustion of 231
By-product coke oven gas, composition and heat value of 231
Calorie 83
Calorific value (see Heat value ).
Calorimeter, coal, Mahler bomb 184
Mahler bomb, method of correction 187
Mahler bomb, method of operation of 185
Calorimeter, steam, compact type of throttling 132
Correction for 131
Location of nozzles for 134
Normal reading 131
Nozzles 134
Separating 133
Throttling 129
Capacity of boilers 264 , 278
Nodules, size of 303
Plasticity of 302
Brick, red 302
Brickwork, care of 307
British thermal unit 83
Burners , blast furnace gas 228
By-product coke oven gas 231
Natural gas 231
Oil 217
Oil, capacity of 221
Oil, mechanical atomizing 219
Oil, operation of 223
Oil, steam atomizing 218
Oil, steam consumption of 220
Burning hydrogen, loss due to moisture formed in 261
By-product coke oven gas burners 231
By-product coke oven gas, combustion of 231
By-product coke oven gas, composition and heat value of 231
Calorie 83
Calorific value (see Heat value ).
Calorimeter, coal, Mahler bomb 184
Mahler bomb, method of correction 187
Mahler bomb, method of operation of 185
Calorimeter, steam, compact type of throttling 132
Correction for 131
Location of nozzles for 134
Normal reading 131
Nozzles 134
Separating 133
Throttling 129
Capacity of boilers 264 , 278
Page 461
As affecting economy 276
Economical loads 283
With bagasse 210
With blast furnace gas 228
With coal 280
With oil fuel 224
Capacity of natural gas burners 229
Capacity of oil burners 221
Carbon dioxide in flue gases 154
Unreliability of readings taken alone 162
Carbon, fixed 165
Incomplete combustion of, loss due to 158
Monoxide, heat value of 151
Monoxide, in flue gases 155
Unconsumed in ash, loss due to 261
Care of boilers when out of service 300
Casings, boilers 307
Causticity of feed water 103
Testing for 105
Celsius thermometer scale 79
Centigrade thermometer scale 79
Chain grate stoker, Babcock & Wilcox 194
Chemicals required in feed water treatment 105
Chimney gases, losses in 158 , 159
Chimneys (see Draft ).
Correction in dimensions for altitude 248
Diameter of 243
Draft available from 241
Draft loss in 239
For blast furnace gas 253
For oil fuel 251
For wood fuel 254
Economical loads 283
With bagasse 210
With blast furnace gas 228
With coal 280
With oil fuel 224
Capacity of natural gas burners 229
Capacity of oil burners 221
Carbon dioxide in flue gases 154
Unreliability of readings taken alone 162
Carbon, fixed 165
Incomplete combustion of, loss due to 158
Monoxide, heat value of 151
Monoxide, in flue gases 155
Unconsumed in ash, loss due to 261
Care of boilers when out of service 300
Casings, boilers 307
Causticity of feed water 103
Testing for 105
Celsius thermometer scale 79
Centigrade thermometer scale 79
Chain grate stoker, Babcock & Wilcox 194
Chemicals required in feed water treatment 105
Chimney gases, losses in 158 , 159
Chimneys (see Draft ).
Correction in dimensions for altitude 248
Diameter of 243
Draft available from 241
Draft loss in 239
For blast furnace gas 253
For oil fuel 251
For wood fuel 254
Page 462
Height of 243
Horse power they will serve 250
Circulation of water in Babcock & Wilcox boilers 57 , 66
Of water in steam boilers 28
62 , 66 ,
Results of defective
67
Classification of coals 166
Fire brick 304
Feed water difficulties 100
Fuels 165
Cleaners, turbine tube 299
Cleaning, ease of, Babcock & Wilcox boilers 73
Closed feed water heaters 111
Coal, Alaska 169
Analyses and heat value 177
Analysis, proximate 176
Analysis, ultimate 173
Anthracite 166
Bituminous 167
Cannel 167
Classification of 165 , 166
Combustion of 190
Comparison with oil 214
Consumption, increase due to superheat 139
Distribution of 167
Formation of 165
Lignite 167
Records 293
Semi-anthracite 166
Semi-bituminous 166
Sizes of anthracite 190
Sizes of bituminous 191
Horse power they will serve 250
Circulation of water in Babcock & Wilcox boilers 57 , 66
Of water in steam boilers 28
62 , 66 ,
Results of defective
67
Classification of coals 166
Fire brick 304
Feed water difficulties 100
Fuels 165
Cleaners, turbine tube 299
Cleaning, ease of, Babcock & Wilcox boilers 73
Closed feed water heaters 111
Coal, Alaska 169
Analyses and heat value 177
Analysis, proximate 176
Analysis, ultimate 173
Anthracite 166
Bituminous 167
Cannel 167
Classification of 165 , 166
Combustion of 190
Comparison with oil 214
Consumption, increase due to superheat 139
Distribution of 167
Formation of 165
Lignite 167
Records 293
Semi-anthracite 166
Semi-bituminous 166
Sizes of anthracite 190
Sizes of bituminous 191
Page 463
Code of A. S. M. E. for boiler testing 267
Coefficient of expansion of various substances 87
Coke 171
Oven gas, by-product, burners 231
Oven gas, by-product, combustion of 231
Oven gas, by-product, composition and heat value of 231
Coking method of firing 195
Color as indication of temperature 91
Combination furnaces 224
Combustible in fuels 150
Combustion 150
Air required for 152 , 156
Air supplied for 157
Combustion of coal 190
Of gaseous fuels 227
Of liquid fuels 212
Of solid fuels other than coal 201
Composition of bagasse 205
Blast furnace gas 227
By-product coke oven gas 231
Coals 177
Natural gas 229
Oil 213
Wood 201
Compounds, boiler 109
Compressibility of water 97
Compression of fire brick 303
Condensation, effect of superheated steam on 140
In steam pipes 313
Consumption, heat, of engines 141
Correction, stem, for thermometers 80
For normal reading in steam calorimeter 131
Coefficient of expansion of various substances 87
Coke 171
Oven gas, by-product, burners 231
Oven gas, by-product, combustion of 231
Oven gas, by-product, composition and heat value of 231
Coking method of firing 195
Color as indication of temperature 91
Combination furnaces 224
Combustible in fuels 150
Combustion 150
Air required for 152 , 156
Air supplied for 157
Combustion of coal 190
Of gaseous fuels 227
Of liquid fuels 212
Of solid fuels other than coal 201
Composition of bagasse 205
Blast furnace gas 227
By-product coke oven gas 231
Coals 177
Natural gas 229
Oil 213
Wood 201
Compounds, boiler 109
Compressibility of water 97
Compression of fire brick 303
Condensation, effect of superheated steam on 140
In steam pipes 313
Consumption, heat, of engines 141
Correction, stem, for thermometers 80
For normal reading in steam calorimeter 131
Page 464
For radiation, bomb calorimeter 187
Corrosion 101 , 106
Coverings, pipe 315
52 , 53 ,
Cross drum, Babcock & Wilcox boiler
60
Dry steam with 71
Draft area as affecting economy in Babcock & Wilcox boilers 70
Available from chimneys 241
Draft loss in chimneys 239
Loss in boilers 245
Loss in flues 243
Loss in furnaces 245
Draft required for anthracite 246
Required for various fuels 246
Drums, Babcock & Wilcox, cross 53
Cross, boxes 50
Heads 49
Longitudinal 49
Manholes 49
Nozzles on 50
Dry steam in Babcock & Wilcox boilers 71
Density of gases 147
Steam 115
Dulong’s formula for heating value 173
Ebullition, point of 86 [Pg 333]
Economizers 111
Efficiency of boilers, chart of 258
Combustible basis 256
Dry coal basis 256
Increase in, due to superheaters 139
Losses in (see Heat balance ) 259
Testing 267
Corrosion 101 , 106
Coverings, pipe 315
52 , 53 ,
Cross drum, Babcock & Wilcox boiler
60
Dry steam with 71
Draft area as affecting economy in Babcock & Wilcox boilers 70
Available from chimneys 241
Draft loss in chimneys 239
Loss in boilers 245
Loss in flues 243
Loss in furnaces 245
Draft required for anthracite 246
Required for various fuels 246
Drums, Babcock & Wilcox, cross 53
Cross, boxes 50
Heads 49
Longitudinal 49
Manholes 49
Nozzles on 50
Dry steam in Babcock & Wilcox boilers 71
Density of gases 147
Steam 115
Dulong’s formula for heating value 173
Ebullition, point of 86 [Pg 333]
Economizers 111
Efficiency of boilers, chart of 258
Combustible basis 256
Dry coal basis 256
Increase in, due to superheaters 139
Losses in (see Heat balance ) 259
Testing 267
Page 465
Test vs. operating 278
Variation in, with capacity 284
With coal 288
With oil 224
Ellison draft gauge 254
Engine, Hero’s 13
Engines, superheated steam with 141
Equivalent evaporation from and at 212 degrees 116
Eve’s boiler 24
Evolution of Babcock & Wilcox boiler 39
Exhaust steam from auxiliaries 113
Expansion, coefficient of 87
Of fire brick 303
Of pipe 315
Pyrometer 89
Factor of evaporation 117
Fahrenheit thermometer scale 79
Fans, use of, in waste heat work 233
Feed water , air in 106
As affecting capacity 279
Boiler 100
Feed water heaters, closed 111
Economizers 111
Open 111
Feed water heating, methods of 111
Saving by 110
Feed water, impurities in 100
Lines 312
Method of feeding 110
Feed water treatment 102
Chemical 102
Chemical, lime and soda process 102
Variation in, with capacity 284
With coal 288
With oil 224
Ellison draft gauge 254
Engine, Hero’s 13
Engines, superheated steam with 141
Equivalent evaporation from and at 212 degrees 116
Eve’s boiler 24
Evolution of Babcock & Wilcox boiler 39
Exhaust steam from auxiliaries 113
Expansion, coefficient of 87
Of fire brick 303
Of pipe 315
Pyrometer 89
Factor of evaporation 117
Fahrenheit thermometer scale 79
Fans, use of, in waste heat work 233
Feed water , air in 106
As affecting capacity 279
Boiler 100
Feed water heaters, closed 111
Economizers 111
Open 111
Feed water heating, methods of 111
Saving by 110
Feed water, impurities in 100
Lines 312
Method of feeding 110
Feed water treatment 102
Chemical 102
Chemical, lime and soda process 102
Page 466
Chemical, lime process 102
Chemical, soda process 102
Chemicals used in lime and soda process 105
Combined heat and chemical 105
Heat 102
Less usual reagents 106
Firing, advantages of stoker 195
Methods for anthracite 190
Bituminous 193
Lignite 195
Fittings, handhole in Babcock & Wilcox boilers 50 , 51
Pipe 311
Superheated steam 145
With Babcock & Wilcox boilers 55
Fixtures with Babcock & Wilcox boilers 55
Flanges, pipe 309
Flow of steam into pressure above atmosphere 317
Into the atmosphere 328
Through orifices 317
Through pipes 317
Flue gas analysis 155
Conversion of volumetric to weight 161
Methods of making 160
Object of 155
Orsat apparatus 159
Flue gas, composition of 155
Losses in 158 , 159
Weight per pound of carbon in fuel 158
Weight per pound of fuel 158
Weight resulting from combustion 157
Foaming 102 , 107
Fuel analysis, proximate 176
Chemical, soda process 102
Chemicals used in lime and soda process 105
Combined heat and chemical 105
Heat 102
Less usual reagents 106
Firing, advantages of stoker 195
Methods for anthracite 190
Bituminous 193
Lignite 195
Fittings, handhole in Babcock & Wilcox boilers 50 , 51
Pipe 311
Superheated steam 145
With Babcock & Wilcox boilers 55
Fixtures with Babcock & Wilcox boilers 55
Flanges, pipe 309
Flow of steam into pressure above atmosphere 317
Into the atmosphere 328
Through orifices 317
Through pipes 317
Flue gas analysis 155
Conversion of volumetric to weight 161
Methods of making 160
Object of 155
Orsat apparatus 159
Flue gas, composition of 155
Losses in 158 , 159
Weight per pound of carbon in fuel 158
Weight per pound of fuel 158
Weight resulting from combustion 157
Foaming 102 , 107
Fuel analysis, proximate 176
Page 467
Ultimate 173
Fuel calorimeter, Mabler bomb 184
Tests, method of making 186
Fuels, classification of 165
Gaseous, and their combustion 227
Fuels, liquid, and their combustion 212
Solid, coal 190
Solid, other than coal 201
Furnace, bagasse 209
Blast furnace gas 228
By-product coke oven gas 231
Combination wood and oil 225
Efficiency of 283
Natural gas 229
Peabody oil 222
Webster 55
Wood burning 201 , 202
Galvanic action 107
Gas, blast furnace, burners 228
Combustion of 228
Composition of 227
Gas, by-product coke oven, burners 231
Combustion of 231
Composition of and heat value 231
Gas, natural, burners 229
Combustion of 229
Composition and heat value of 229
Gases, chimney, losses in 158 , 159
Density of 163
Flue (see Flue gases ).
Path of in Babcock & Wilcox boilers 57
Waste (see Waste heat ) 232
Fuel calorimeter, Mabler bomb 184
Tests, method of making 186
Fuels, classification of 165
Gaseous, and their combustion 227
Fuels, liquid, and their combustion 212
Solid, coal 190
Solid, other than coal 201
Furnace, bagasse 209
Blast furnace gas 228
By-product coke oven gas 231
Combination wood and oil 225
Efficiency of 283
Natural gas 229
Peabody oil 222
Webster 55
Wood burning 201 , 202
Galvanic action 107
Gas, blast furnace, burners 228
Combustion of 228
Composition of 227
Gas, by-product coke oven, burners 231
Combustion of 231
Composition of and heat value 231
Gas, natural, burners 229
Combustion of 229
Composition and heat value of 229
Gases, chimney, losses in 158 , 159
Density of 163
Flue (see Flue gases ).
Path of in Babcock & Wilcox boilers 57
Waste (see Waste heat ) 232
Page 468
Gaskets 312
Gauges, draft, Barrus 254
Ellison 255
Peabody 255
U-tube 254
Gauges, vacuum 117
Grate ratio for anthracite 191
Gravity of oils 214
Grooving 102
Guerney’s boiler 24
Handhole fittings for Babcock & Wilcox boilers 50 , 51
Handholes in Babcock & Wilcox boilers 50 , 51
Hardness of boiler feed water 102
Permanent 102
Temporary 102
Testing for 105
Hardness of fire brick 303
Heat and chemical methods of treating feed water 105
And its measurement 79
Balance 262
Consumption of engines 141
Latent 84
Of liquid 120
Sensible 84
Specific (see Specific heat ) 83
Total 86
Transfer 323
Heat value of bagasse 205
By-product coke oven gas 231
Coal 177
Heat value of fuels, determination of 173
Determination of Kent’s approximate method 183
Gauges, draft, Barrus 254
Ellison 255
Peabody 255
U-tube 254
Gauges, vacuum 117
Grate ratio for anthracite 191
Gravity of oils 214
Grooving 102
Guerney’s boiler 24
Handhole fittings for Babcock & Wilcox boilers 50 , 51
Handholes in Babcock & Wilcox boilers 50 , 51
Hardness of boiler feed water 102
Permanent 102
Temporary 102
Testing for 105
Hardness of fire brick 303
Heat and chemical methods of treating feed water 105
And its measurement 79
Balance 262
Consumption of engines 141
Latent 84
Of liquid 120
Sensible 84
Specific (see Specific heat ) 83
Total 86
Transfer 323
Heat value of bagasse 205
By-product coke oven gas 231
Coal 177
Heat value of fuels, determination of 173
Determination of Kent’s approximate method 183
Page 469
High and low 174
Heat value of natural gas 229
Oil 215
Wood 201
Heat waste (see Waste heat ) 232
Heaters, feed water, closed 111
Economizers 111
Open 111
Heating feed water, saving by 110
Hero’s engine 13
High and low heat value of fuels 174
High pressure steam, advantages of use of 119
High temperature measurements, accuracy of 89
Horse power, boiler 265
Evaporation (actual) corresponding to 288
Rated boiler 265
Stacks for various, of boilers 250
Hydrogen in flue gases 156
Ice, specific heat of 99 [Pg 334]
“Idalia”, tests with superheated steam on yacht 143
Impurities in boiler feed water 100
Incomplete combustion of carbon, loss due to 158
Injectors, efficiency of 112
Relative efficiency of, and pumps 112
Iron alum in feed water treatment 106
Kent, Wm., determination of heat value from analysis 183
Stack table 250
Kindling point 150
Latent heat 84 , 115
Laying of fire brick 305
Red brick 305
Lignite, analyses of 181
Heat value of natural gas 229
Oil 215
Wood 201
Heat waste (see Waste heat ) 232
Heaters, feed water, closed 111
Economizers 111
Open 111
Heating feed water, saving by 110
Hero’s engine 13
High and low heat value of fuels 174
High pressure steam, advantages of use of 119
High temperature measurements, accuracy of 89
Horse power, boiler 265
Evaporation (actual) corresponding to 288
Rated boiler 265
Stacks for various, of boilers 250
Hydrogen in flue gases 156
Ice, specific heat of 99 [Pg 334]
“Idalia”, tests with superheated steam on yacht 143
Impurities in boiler feed water 100
Incomplete combustion of carbon, loss due to 158
Injectors, efficiency of 112
Relative efficiency of, and pumps 112
Iron alum in feed water treatment 106
Kent, Wm., determination of heat value from analysis 183
Stack table 250
Kindling point 150
Latent heat 84 , 115
Laying of fire brick 305
Red brick 305
Lignite, analyses of 181
Page 470
Combustion of 195
Lime and soda treatment of boiler feed 102
Used in chemical treatment of feed 105
Lime treatment of boiler feed water 102
Liquid fuels and their combustion 212
Loads, economical boiler 283
Losses due to excess air 158
Due to unburned carbon 158
Due to unconsumed carbon in the ash 261
Losses in efficiency (see Heat balance ).
In flue gases 158 , 159
Low water in boilers 298
Melting points of metals 91
Mercurial pyrometers 89
Moisture in coal, determination of 176
In fuels, losses due to 259
In steam, determination of 129
Mud drum of Babcock & Wilcox boiler 51
Napier’s formula for flow of steam 321
Natural gas, burners for 229
Combustion of 229
Composition and heat value of 229
Nitrate of silver in testing feed water 105
Nitrogen, as indication of excess air 157
In air 147
In flue gases 157
Nodules, fire brick, ratio of 303
Size of 303
Normal reading, throttling calorimeter 131
Nozzles, steam sampling for calorimeter 134
Location of 134
Oil fuel, burners (see Burners ).
Lime and soda treatment of boiler feed 102
Used in chemical treatment of feed 105
Lime treatment of boiler feed water 102
Liquid fuels and their combustion 212
Loads, economical boiler 283
Losses due to excess air 158
Due to unburned carbon 158
Due to unconsumed carbon in the ash 261
Losses in efficiency (see Heat balance ).
In flue gases 158 , 159
Low water in boilers 298
Melting points of metals 91
Mercurial pyrometers 89
Moisture in coal, determination of 176
In fuels, losses due to 259
In steam, determination of 129
Mud drum of Babcock & Wilcox boiler 51
Napier’s formula for flow of steam 321
Natural gas, burners for 229
Combustion of 229
Composition and heat value of 229
Nitrate of silver in testing feed water 105
Nitrogen, as indication of excess air 157
In air 147
In flue gases 157
Nodules, fire brick, ratio of 303
Size of 303
Normal reading, throttling calorimeter 131
Nozzles, steam sampling for calorimeter 134
Location of 134
Oil fuel, burners (see Burners ).
Page 471
Capacity with 224
Combustion of 217
Comparison with coal 214
Composition and heat value of 213
Efficiency with 224
Furnaces for 221
Gravity of 214
In combination with other fuels 224
Stacks for 251
Tests with 224
Open hearth furnace, Babcock & Wilcox boiler set for utilizing
waste heat from 236
Open heaters, feed water 111
Operation of boilers 291
Optical pyrometers 91
Orsat apparatus 160
Oxalate of soda in feed water treatment 106
Oxygen in air 147
Flue gases 155
Peabody draft gauge 255
Formulae for coal calorimeter correction 188
Furnace for oil fuel 221 , 222
Oil burner 218
Peat 167
Perkins’ boiler 24
Pfaundler’s method of coal calorimeter radiation correction 187
Pipe coverings 315
Data 308
Expansion of 315
Pipe fittings 311
Flanges 309
Flow of steam through 317
Combustion of 217
Comparison with coal 214
Composition and heat value of 213
Efficiency with 224
Furnaces for 221
Gravity of 214
In combination with other fuels 224
Stacks for 251
Tests with 224
Open hearth furnace, Babcock & Wilcox boiler set for utilizing
waste heat from 236
Open heaters, feed water 111
Operation of boilers 291
Optical pyrometers 91
Orsat apparatus 160
Oxalate of soda in feed water treatment 106
Oxygen in air 147
Flue gases 155
Peabody draft gauge 255
Formulae for coal calorimeter correction 188
Furnace for oil fuel 221 , 222
Oil burner 218
Peat 167
Perkins’ boiler 24
Pfaundler’s method of coal calorimeter radiation correction 187
Pipe coverings 315
Data 308
Expansion of 315
Pipe fittings 311
Flanges 309
Flow of steam through 317
Page 472
Radiation from bare and covered 314
Sizes 312
Supports for 315
Piping, boiler room 308
Pitting 102
Plant records, coal 293
Draft 294
Temperature 294
Water 293
Plasticity of fire brick 302
Pressed fuels 171
Priming in boilers 102
Methods of treating for 107
Properties of water 96
Proximate analyses of coal 177
Proximate analysis 173
Method of making 176
Pulverized fuels 170
Pump, efficiency of feed 112
Pyrometers, expansion 89
Mercurial 89
Optical 91
Radiation 90
Thermo-electric 90
Quality of steam 129
Radiation correction for coal calorimeter 187 , 188
Correction for steam calorimeter 131
Effect of superheated steam on 140
From pipes 314
Losses in efficiency due to 307
Pyrometers 90
Ratio of air supplied to that required for combustion 157
Sizes 312
Supports for 315
Piping, boiler room 308
Pitting 102
Plant records, coal 293
Draft 294
Temperature 294
Water 293
Plasticity of fire brick 302
Pressed fuels 171
Priming in boilers 102
Methods of treating for 107
Properties of water 96
Proximate analyses of coal 177
Proximate analysis 173
Method of making 176
Pulverized fuels 170
Pump, efficiency of feed 112
Pyrometers, expansion 89
Mercurial 89
Optical 91
Radiation 90
Thermo-electric 90
Quality of steam 129
Radiation correction for coal calorimeter 187 , 188
Correction for steam calorimeter 131
Effect of superheated steam on 140
From pipes 314
Losses in efficiency due to 307
Pyrometers 90
Ratio of air supplied to that required for combustion 157
Page 473
Reagents, less usual in feed treatment 106
Records, plant, coal 293
Draft 294
Temperature 294
Water 293
Requirements of steam boilers 27
As indicated by evolution of Babcock & Wilcox 45
Rumsey’s boiler 23
Safety of Babcock & Wilcox boilers 66
Salts responsible for scale 101
Solubility of 101
Sampling coal 271
Nozzles for steam 134
Nozzles for steam, location of 134
Steam 134
Steam, errors in 135
Saturated air 149
Saving by heating feed 110
With superheat in “Idalia” tests 143
With superheat in prime movers 140 , 142
Scale (see Thermometers ) 101
Sea water, composition of 97
Sections, Babcock & Wilcox boiler 50
Selection of boilers 277
Sensible heat 84
Separating steam calorimeter 132
Sizes of anthracite coal 190
Bituminous coal 191
Smoke, methods of eliminating 197
Smokelessness, relative nature of 197
With hand-fired furnaces 199
With stoker-fired furnaces 199
Records, plant, coal 293
Draft 294
Temperature 294
Water 293
Requirements of steam boilers 27
As indicated by evolution of Babcock & Wilcox 45
Rumsey’s boiler 23
Safety of Babcock & Wilcox boilers 66
Salts responsible for scale 101
Solubility of 101
Sampling coal 271
Nozzles for steam 134
Nozzles for steam, location of 134
Steam 134
Steam, errors in 135
Saturated air 149
Saving by heating feed 110
With superheat in “Idalia” tests 143
With superheat in prime movers 140 , 142
Scale (see Thermometers ) 101
Sea water, composition of 97
Sections, Babcock & Wilcox boiler 50
Selection of boilers 277
Sensible heat 84
Separating steam calorimeter 132
Sizes of anthracite coal 190
Bituminous coal 191
Smoke, methods of eliminating 197
Smokelessness, relative nature of 197
With hand-fired furnaces 199
With stoker-fired furnaces 199
Page 474
Soda, lime and, treatment of feed 103
Oxalate of, in treatment of feed 106
Removal of scale aided by 300
Silicate of, in treatment of feed 106
Treatment of boiler feed 103
Space occupied by Babcock & Wilcox boilers 66
Specific heat 83
Specific heat of air 148
Ice 99
Saturated steam 99
Specific heat of superheated steam 137 [Pg 335]
Various solids, liquids and gases 85
Water 99
Spreading method of firing 193
Stacks and draft (see Chimneys ) 237
Stacks for blast furnace gas 228
Oil fuel 251
Wood 202 , 254
Stayed surfaces, absence of, in Babcock & Wilcox boilers 69
Difficulties arising from use of 67
Steam 115
As aid to combustion of anthracite 191
As aid to combustion of lignite 195
Consumption of prime movers 289
Density of 115
Flow of, into atmosphere 320
Flow of, into pressure above atmosphere 318
Flow of, through pipes 317
High pressure, advantage of 119
History of generation and use of 13
Making, theory of 92
Moisture in 129
Oxalate of, in treatment of feed 106
Removal of scale aided by 300
Silicate of, in treatment of feed 106
Treatment of boiler feed 103
Space occupied by Babcock & Wilcox boilers 66
Specific heat 83
Specific heat of air 148
Ice 99
Saturated steam 99
Specific heat of superheated steam 137 [Pg 335]
Various solids, liquids and gases 85
Water 99
Spreading method of firing 193
Stacks and draft (see Chimneys ) 237
Stacks for blast furnace gas 228
Oil fuel 251
Wood 202 , 254
Stayed surfaces, absence of, in Babcock & Wilcox boilers 69
Difficulties arising from use of 67
Steam 115
As aid to combustion of anthracite 191
As aid to combustion of lignite 195
Consumption of prime movers 289
Density of 115
Flow of, into atmosphere 320
Flow of, into pressure above atmosphere 318
Flow of, through pipes 317
High pressure, advantage of 119
History of generation and use of 13
Making, theory of 92
Moisture in 129
Page 475
Properties of, for vacuum 119
Properties of saturated 122
Properties of superheated 125
Quality of 129
Saturated 115
Specific heat of saturated 99
Specific heat of superheated 137
Specific volume of 115
Superheated 137
Superheaters (see Superheated steam ).
Steaming, quick, with Babcock & Wilcox boilers 73
Stem Correction, thermometer 80
Stevens, John, boiler 23
Stevens, John Cox, boiler 23
Stokers, automatic, advantages of 195
Babcock & Wilcox chain grate 194
Overfeed 196
Smokelessness with 199
Traveling grate 197
Underfeed 196
Superheated steam 137
Additional fuel for 139
Effect on condensation 140
Effect on radiation 140
Fittings for use with 145
“Idalia” tests with 143
Specific heat of 137
Variation in temperature of 145
With turbines 142
Superheater, Babcock & Wilcox 136
Effect of on boiler efficiency 139
Supports, Babcock & Wilcox boiler 52 , 53
Properties of saturated 122
Properties of superheated 125
Quality of 129
Saturated 115
Specific heat of saturated 99
Specific heat of superheated 137
Specific volume of 115
Superheated 137
Superheaters (see Superheated steam ).
Steaming, quick, with Babcock & Wilcox boilers 73
Stem Correction, thermometer 80
Stevens, John, boiler 23
Stevens, John Cox, boiler 23
Stokers, automatic, advantages of 195
Babcock & Wilcox chain grate 194
Overfeed 196
Smokelessness with 199
Traveling grate 197
Underfeed 196
Superheated steam 137
Additional fuel for 139
Effect on condensation 140
Effect on radiation 140
Fittings for use with 145
“Idalia” tests with 143
Specific heat of 137
Variation in temperature of 145
With turbines 142
Superheater, Babcock & Wilcox 136
Effect of on boiler efficiency 139
Supports, Babcock & Wilcox boiler 52 , 53
Page 476
Tan bark 210
Tar, water gas 225
Temperature, accuracy of high, measurements 89
As indicated by color 91
Of waste gases 232
Records 294
Test conditions vs. operating conditions 278
Testing, boiler, A. S. M. E. code for 267
Tests of Babcock & Wilcox boilers with bagasse 210
Coal 280
Oil 224
Theory of steam making 92
Thermo-electric pyrometers 90
Thermometer scale , celsius 79
Thermometer scale, centigrade 76
Fahrenheit 79
Réaumur 79
Thermometer scales, comparison of 80
Conversion of 80
Thermometer stem correction for 80
Thermometers, glass for 79
Throttling calorimeter 129
Total heat 86 , 115
Treatment of boiler feed water (see Feed water ) 102
Chemicals used in 105
Less usual reagents in 106
Tube data 309
Doors in Babcock & Wilcox boilers 53
Tubes in Babcock & Wilcox boilers 50
Ultimate analyses of coal 183
Analysis of fuels 173
Unaccounted losses in efficiency 261
Tar, water gas 225
Temperature, accuracy of high, measurements 89
As indicated by color 91
Of waste gases 232
Records 294
Test conditions vs. operating conditions 278
Testing, boiler, A. S. M. E. code for 267
Tests of Babcock & Wilcox boilers with bagasse 210
Coal 280
Oil 224
Theory of steam making 92
Thermo-electric pyrometers 90
Thermometer scale , celsius 79
Thermometer scale, centigrade 76
Fahrenheit 79
Réaumur 79
Thermometer scales, comparison of 80
Conversion of 80
Thermometer stem correction for 80
Thermometers, glass for 79
Throttling calorimeter 129
Total heat 86 , 115
Treatment of boiler feed water (see Feed water ) 102
Chemicals used in 105
Less usual reagents in 106
Tube data 309
Doors in Babcock & Wilcox boilers 53
Tubes in Babcock & Wilcox boilers 50
Ultimate analyses of coal 183
Analysis of fuels 173
Unaccounted losses in efficiency 261
Page 477
Unconsumed carbon in ash 261
Units, boiler, number of 289
Size of 289
Units, British thermal 83
Unreliability of CO 2 readings alone 162
Vacuum gauges 117
Properties of steam for 119
Valves used with superheated steam 312
Variation in properties of saturated steam 119
Superheat from boilers 145
Volume of air 147
Water 96
Volume, specific, of steam 115
Waste heat , auxiliary grates with boilers for 235
Babcock & Wilcox boilers set for use with 236
Boiler design for 233
Curve of temperature, heat absorption, and heating surface 235
Draft for 233
Fans for use with 233
Power obtainable from 232
Temperature of, from various processes 232
Utilization of 232
Water, air in boiler feed 106
Boiling points of 97
Compressibility of 97
Water feed, impurities in 100
Methods of feeding to boiler 132
Saving by heating 110
Treatment (see Feed water ).
Water-gas tar 225
Heat of the liquid 120
Path of, in Babcock & Wilcox boilers 57
Units, boiler, number of 289
Size of 289
Units, British thermal 83
Unreliability of CO 2 readings alone 162
Vacuum gauges 117
Properties of steam for 119
Valves used with superheated steam 312
Variation in properties of saturated steam 119
Superheat from boilers 145
Volume of air 147
Water 96
Volume, specific, of steam 115
Waste heat , auxiliary grates with boilers for 235
Babcock & Wilcox boilers set for use with 236
Boiler design for 233
Curve of temperature, heat absorption, and heating surface 235
Draft for 233
Fans for use with 233
Power obtainable from 232
Temperature of, from various processes 232
Utilization of 232
Water, air in boiler feed 106
Boiling points of 97
Compressibility of 97
Water feed, impurities in 100
Methods of feeding to boiler 132
Saving by heating 110
Treatment (see Feed water ).
Water-gas tar 225
Heat of the liquid 120
Path of, in Babcock & Wilcox boilers 57
Page 478
Properties of 96
Records 293
Specific heat of 99
Volume of 96
Weight of 96 , 120
Watt, James 17
Weathering of coal 169
Webster furnace 55
Weight of air 147
Wilcox boiler 25
Wood, combustion of dry 202
Wet 203
Composition and heat value of 201
Furnace design for 201
Moisture in 201
Sawmill refuse 202
Woolf s boiler 24
Zero, absolute 81
Records 293
Specific heat of 99
Volume of 96
Weight of 96 , 120
Watt, James 17
Weathering of coal 169
Webster furnace 55
Weight of air 147
Wilcox boiler 25
Wood, combustion of dry 202
Wet 203
Composition and heat value of 201
Furnace design for 201
Moisture in 201
Sawmill refuse 202
Woolf s boiler 24
Zero, absolute 81
Page 479
*** END OF THE PROJECT GUTENBERG EBOOK STEAM, ITS
GENERATION AND USE ***
Updated editions will replace the previous one—the old editions will be
renamed.
Creating the works from print editions not protected by U.S. copyright law
means that no one owns a United States copyright in these works, so the
Foundation (and you!) can copy and distribute it in the United States
without permission and without paying copyright royalties. Special rules,
set forth in the General Terms of Use part of this license, apply to copying
and distributing Project Gutenberg™ electronic works to protect the
PROJECT GUTENBERG™ concept and trademark. Project Gutenberg is a
registered trademark, and may not be used if you charge for an eBook,
except by following the terms of the trademark license, including paying
royalties for use of the Project Gutenberg trademark. If you do not charge
anything for copies of this eBook, complying with the trademark license is
very easy. You may use this eBook for nearly any purpose such as creation
of derivative works, reports, performances and research. Project Gutenberg
eBooks may be modified and printed and given away—you may do
practically ANYTHING in the United States with eBooks not protected by
U.S. copyright law. Redistribution is subject to the trademark license,
especially commercial redistribution.
START: FULL LICENSE
GENERATION AND USE ***
Updated editions will replace the previous one—the old editions will be
renamed.
Creating the works from print editions not protected by U.S. copyright law
means that no one owns a United States copyright in these works, so the
Foundation (and you!) can copy and distribute it in the United States
without permission and without paying copyright royalties. Special rules,
set forth in the General Terms of Use part of this license, apply to copying
and distributing Project Gutenberg™ electronic works to protect the
PROJECT GUTENBERG™ concept and trademark. Project Gutenberg is a
registered trademark, and may not be used if you charge for an eBook,
except by following the terms of the trademark license, including paying
royalties for use of the Project Gutenberg trademark. If you do not charge
anything for copies of this eBook, complying with the trademark license is
very easy. You may use this eBook for nearly any purpose such as creation
of derivative works, reports, performances and research. Project Gutenberg
eBooks may be modified and printed and given away—you may do
practically ANYTHING in the United States with eBooks not protected by
U.S. copyright law. Redistribution is subject to the trademark license,
especially commercial redistribution.
START: FULL LICENSE
Page 480
THE FULL PROJECT GUTENBERG™ LICENSE
PLEASE READ THIS BEFORE YOU DISTRIBUTE OR USE THIS WORK
To protect the Project Gutenberg™ mission of promoting the free
distribution of electronic works, by using or distributing this work (or any
other work associated in any way with the phrase “Project Gutenberg”), you
agree to comply with all the terms of the Full Project Gutenberg License
available with this file or online at www.gutenberg.org/license.
Section 1. General Terms of Use and Redistributing
Project Gutenberg electronic works
1.A. By reading or using any part of this Project Gutenberg electronic work,
you indicate that you have read, understand, agree to and accept all the
terms of this license and intellectual property (trademark/copyright)
agreement. If you do not agree to abide by all the terms of this agreement,
you must cease using and return or destroy all copies of Project Gutenberg
electronic works in your possession. If you paid a fee for obtaining a copy
of or access to a Project Gutenberg electronic work and you do not agree to
be bound by the terms of this agreement, you may obtain a refund from the
person or entity to whom you paid the fee as set forth in paragraph 1.E.8.
1.B. “Project Gutenberg” is a registered trademark. It may only be used on
or associated in any way with an electronic work by people who agree to be
bound by the terms of this agreement. There are a few things that you can
do with most Project Gutenberg electronic works even without complying
with the full terms of this agreement. See paragraph 1.C below. There are a
lot of things you can do with Project Gutenberg electronic works if you
follow the terms of this agreement and help preserve free future access to
Project Gutenberg electronic works. See paragraph 1.E below.
1.C. The Project Gutenberg Literary Archive Foundation (“the Foundation”
or PGLAF), owns a compilation copyright in the collection of Project
Gutenberg electronic works. Nearly all the individual works in the
collection are in the public domain in the United States. If an individual
work is unprotected by copyright law in the United States and you are
PLEASE READ THIS BEFORE YOU DISTRIBUTE OR USE THIS WORK
To protect the Project Gutenberg™ mission of promoting the free
distribution of electronic works, by using or distributing this work (or any
other work associated in any way with the phrase “Project Gutenberg”), you
agree to comply with all the terms of the Full Project Gutenberg License
available with this file or online at www.gutenberg.org/license.
Section 1. General Terms of Use and Redistributing
Project Gutenberg electronic works
1.A. By reading or using any part of this Project Gutenberg electronic work,
you indicate that you have read, understand, agree to and accept all the
terms of this license and intellectual property (trademark/copyright)
agreement. If you do not agree to abide by all the terms of this agreement,
you must cease using and return or destroy all copies of Project Gutenberg
electronic works in your possession. If you paid a fee for obtaining a copy
of or access to a Project Gutenberg electronic work and you do not agree to
be bound by the terms of this agreement, you may obtain a refund from the
person or entity to whom you paid the fee as set forth in paragraph 1.E.8.
1.B. “Project Gutenberg” is a registered trademark. It may only be used on
or associated in any way with an electronic work by people who agree to be
bound by the terms of this agreement. There are a few things that you can
do with most Project Gutenberg electronic works even without complying
with the full terms of this agreement. See paragraph 1.C below. There are a
lot of things you can do with Project Gutenberg electronic works if you
follow the terms of this agreement and help preserve free future access to
Project Gutenberg electronic works. See paragraph 1.E below.
1.C. The Project Gutenberg Literary Archive Foundation (“the Foundation”
or PGLAF), owns a compilation copyright in the collection of Project
Gutenberg electronic works. Nearly all the individual works in the
collection are in the public domain in the United States. If an individual
work is unprotected by copyright law in the United States and you are
Page 481
located in the United States, we do not claim a right to prevent you from
copying, distributing, performing, displaying or creating derivative works
based on the work as long as all references to Project Gutenberg are
removed. Of course, we hope that you will support the Project Gutenberg
mission of promoting free access to electronic works by freely sharing
Project Gutenberg works in compliance with the terms of this agreement for
keeping the Project Gutenberg name associated with the work. You can
easily comply with the terms of this agreement by keeping this work in the
same format with its attached full Project Gutenberg License when you
share it without charge with others.
1.D. The copyright laws of the place where you are located also govern
what you can do with this work. Copyright laws in most countries are in a
constant state of change. If you are outside the United States, check the
laws of your country in addition to the terms of this agreement before
downloading, copying, displaying, performing, distributing or creating
derivative works based on this work or any other Project Gutenberg work.
The Foundation makes no representations concerning the copyright status
of any work in any country other than the United States.
1.E. Unless you have removed all references to Project Gutenberg:
1.E.1. The following sentence, with active links to, or other immediate
access to, the full Project Gutenberg License must appear prominently
whenever any copy of a Project Gutenberg work (any work on which the
phrase “Project Gutenberg” appears, or with which the phrase “Project
Gutenberg” is associated) is accessed, displayed, performed, viewed, copied
or distributed:
This eBook is for the use of anyone anywhere in the United States
and most other parts of the world at no cost and with almost no
restrictions whatsoever. You may copy it, give it away or re-use it
under the terms of the Project Gutenberg™ License included with
this eBook or online at www.gutenberg.org. If you are not located in
the United States, you will have to check the laws of the country
where you are located before using this eBook.
copying, distributing, performing, displaying or creating derivative works
based on the work as long as all references to Project Gutenberg are
removed. Of course, we hope that you will support the Project Gutenberg
mission of promoting free access to electronic works by freely sharing
Project Gutenberg works in compliance with the terms of this agreement for
keeping the Project Gutenberg name associated with the work. You can
easily comply with the terms of this agreement by keeping this work in the
same format with its attached full Project Gutenberg License when you
share it without charge with others.
1.D. The copyright laws of the place where you are located also govern
what you can do with this work. Copyright laws in most countries are in a
constant state of change. If you are outside the United States, check the
laws of your country in addition to the terms of this agreement before
downloading, copying, displaying, performing, distributing or creating
derivative works based on this work or any other Project Gutenberg work.
The Foundation makes no representations concerning the copyright status
of any work in any country other than the United States.
1.E. Unless you have removed all references to Project Gutenberg:
1.E.1. The following sentence, with active links to, or other immediate
access to, the full Project Gutenberg License must appear prominently
whenever any copy of a Project Gutenberg work (any work on which the
phrase “Project Gutenberg” appears, or with which the phrase “Project
Gutenberg” is associated) is accessed, displayed, performed, viewed, copied
or distributed:
This eBook is for the use of anyone anywhere in the United States
and most other parts of the world at no cost and with almost no
restrictions whatsoever. You may copy it, give it away or re-use it
under the terms of the Project Gutenberg™ License included with
this eBook or online at www.gutenberg.org. If you are not located in
the United States, you will have to check the laws of the country
where you are located before using this eBook.
Page 482
1.E.2. If an individual Project Gutenberg electronic work is derived from
texts not protected by U.S. copyright law (does not contain a notice
indicating that it is posted with permission of the copyright holder), the
work can be copied and distributed to anyone in the United States without
paying any fees or charges. If you are redistributing or providing access to a
work with the phrase “Project Gutenberg” associated with or appearing on
the work, you must comply either with the requirements of paragraphs
1.E.1 through 1.E.7 or obtain permission for the use of the work and the
Project Gutenberg trademark as set forth in paragraphs 1.E.8 or 1.E.9.
1.E.3. If an individual Project Gutenberg electronic work is posted with the
permission of the copyright holder, your use and distribution must comply
with both paragraphs 1.E.1 through 1.E.7 and any additional terms imposed
by the copyright holder. Additional terms will be linked to the Project
Gutenberg License for all works posted with the permission of the
copyright holder found at the beginning of this work.
1.E.4. Do not unlink or detach or remove the full Project Gutenberg License
terms from this work, or any files containing a part of this work or any
other work associated with Project Gutenberg.
1.E.5. Do not copy, display, perform, distribute or redistribute this
electronic work, or any part of this electronic work, without prominently
displaying the sentence set forth in paragraph 1.E.1 with active links or
immediate access to the full terms of the Project Gutenberg License.
1.E.6. You may convert to and distribute this work in any binary,
compressed, marked up, nonproprietary or proprietary form, including any
word processing or hypertext form. However, if you provide access to or
distribute copies of a Project Gutenberg work in a format other than “Plain
Vanilla ASCII” or other format used in the official version posted on the
official Project Gutenberg website (www.gutenberg.org), you must, at no
additional cost, fee or expense to the user, provide a copy, a means of
exporting a copy, or a means of obtaining a copy upon request, of the work
in its original “Plain Vanilla ASCII” or other form. Any alternate format
must include the full Project Gutenberg License as specified in paragraph
1.E.1.
texts not protected by U.S. copyright law (does not contain a notice
indicating that it is posted with permission of the copyright holder), the
work can be copied and distributed to anyone in the United States without
paying any fees or charges. If you are redistributing or providing access to a
work with the phrase “Project Gutenberg” associated with or appearing on
the work, you must comply either with the requirements of paragraphs
1.E.1 through 1.E.7 or obtain permission for the use of the work and the
Project Gutenberg trademark as set forth in paragraphs 1.E.8 or 1.E.9.
1.E.3. If an individual Project Gutenberg electronic work is posted with the
permission of the copyright holder, your use and distribution must comply
with both paragraphs 1.E.1 through 1.E.7 and any additional terms imposed
by the copyright holder. Additional terms will be linked to the Project
Gutenberg License for all works posted with the permission of the
copyright holder found at the beginning of this work.
1.E.4. Do not unlink or detach or remove the full Project Gutenberg License
terms from this work, or any files containing a part of this work or any
other work associated with Project Gutenberg.
1.E.5. Do not copy, display, perform, distribute or redistribute this
electronic work, or any part of this electronic work, without prominently
displaying the sentence set forth in paragraph 1.E.1 with active links or
immediate access to the full terms of the Project Gutenberg License.
1.E.6. You may convert to and distribute this work in any binary,
compressed, marked up, nonproprietary or proprietary form, including any
word processing or hypertext form. However, if you provide access to or
distribute copies of a Project Gutenberg work in a format other than “Plain
Vanilla ASCII” or other format used in the official version posted on the
official Project Gutenberg website (www.gutenberg.org), you must, at no
additional cost, fee or expense to the user, provide a copy, a means of
exporting a copy, or a means of obtaining a copy upon request, of the work
in its original “Plain Vanilla ASCII” or other form. Any alternate format
must include the full Project Gutenberg License as specified in paragraph
1.E.1.
Page 483
1.E.7. Do not charge a fee for access to, viewing, displaying, performing,
copying or distributing any Project Gutenberg works unless you comply
with paragraph 1.E.8 or 1.E.9.
1.E.8. You may charge a reasonable fee for copies of or providing access to
or distributing Project Gutenberg electronic works provided that:
• You pay a royalty fee of 20% of the gross profits you derive from the
use of Project Gutenberg works calculated using the method you
already use to calculate your applicable taxes. The fee is owed to the
owner of the Project Gutenberg trademark, but he has agreed to donate
royalties under this paragraph to the Project Gutenberg Literary
Archive Foundation. Royalty payments must be paid within 60 days
following each date on which you prepare (or are legally required to
prepare) your periodic tax returns. Royalty payments should be clearly
marked as such and sent to the Project Gutenberg Literary Archive
Foundation at the address specified in Section 4, “Information about
donations to the Project Gutenberg Literary Archive Foundation.”
• You provide a full refund of any money paid by a user who notifies
you in writing (or by e-mail) within 30 days of receipt that s/he does
not agree to the terms of the full Project Gutenberg™ License. You
must require such a user to return or destroy all copies of the works
possessed in a physical medium and discontinue all use of and all
access to other copies of Project Gutenberg™ works.
• You provide, in accordance with paragraph 1.F.3, a full refund of any
money paid for a work or a replacement copy, if a defect in the
electronic work is discovered and reported to you within 90 days of
receipt of the work.
• You comply with all other terms of this agreement for free distribution
of Project Gutenberg™ works.
1.E.9. If you wish to charge a fee or distribute a Project Gutenberg™
electronic work or group of works on different terms than are set forth in
this agreement, you must obtain permission in writing from the Project
Gutenberg Literary Archive Foundation, the manager of the Project
copying or distributing any Project Gutenberg works unless you comply
with paragraph 1.E.8 or 1.E.9.
1.E.8. You may charge a reasonable fee for copies of or providing access to
or distributing Project Gutenberg electronic works provided that:
• You pay a royalty fee of 20% of the gross profits you derive from the
use of Project Gutenberg works calculated using the method you
already use to calculate your applicable taxes. The fee is owed to the
owner of the Project Gutenberg trademark, but he has agreed to donate
royalties under this paragraph to the Project Gutenberg Literary
Archive Foundation. Royalty payments must be paid within 60 days
following each date on which you prepare (or are legally required to
prepare) your periodic tax returns. Royalty payments should be clearly
marked as such and sent to the Project Gutenberg Literary Archive
Foundation at the address specified in Section 4, “Information about
donations to the Project Gutenberg Literary Archive Foundation.”
• You provide a full refund of any money paid by a user who notifies
you in writing (or by e-mail) within 30 days of receipt that s/he does
not agree to the terms of the full Project Gutenberg™ License. You
must require such a user to return or destroy all copies of the works
possessed in a physical medium and discontinue all use of and all
access to other copies of Project Gutenberg™ works.
• You provide, in accordance with paragraph 1.F.3, a full refund of any
money paid for a work or a replacement copy, if a defect in the
electronic work is discovered and reported to you within 90 days of
receipt of the work.
• You comply with all other terms of this agreement for free distribution
of Project Gutenberg™ works.
1.E.9. If you wish to charge a fee or distribute a Project Gutenberg™
electronic work or group of works on different terms than are set forth in
this agreement, you must obtain permission in writing from the Project
Gutenberg Literary Archive Foundation, the manager of the Project
Page 484
Gutenberg™ trademark. Contact the Foundation as set forth in Section 3
below.
1.F.
1.F.1. Project Gutenberg volunteers and employees expend considerable
effort to identify, do copyright research on, transcribe and proofread works
not protected by U.S. copyright law in creating the Project Gutenberg™
collection. Despite these efforts, Project Gutenberg™ electronic works, and
the medium on which they may be stored, may contain “Defects,” such as,
but not limited to, incomplete, inaccurate or corrupt data, transcription
errors, a copyright or other intellectual property infringement, a defective or
damaged disk or other medium, a computer virus, or computer codes that
damage or cannot be read by your equipment.
1.F.2. LIMITED WARRANTY, DISCLAIMER OF DAMAGES - Except
for the “Right of Replacement or Refund” described in paragraph 1.F.3, the
Project Gutenberg Literary Archive Foundation, the owner of the Project
Gutenberg™ trademark, and any other party distributing a Project
Gutenberg™ electronic work under this agreement, disclaim all liability to
you for damages, costs and expenses, including legal fees. YOU AGREE
THAT YOU HAVE NO REMEDIES FOR NEGLIGENCE, STRICT
LIABILITY, BREACH OF WARRANTY OR BREACH OF CONTRACT
EXCEPT THOSE PROVIDED IN PARAGRAPH 1.F.3. YOU AGREE
THAT THE FOUNDATION, THE TRADEMARK OWNER, AND ANY
DISTRIBUTOR UNDER THIS AGREEMENT WILL NOT BE LIABLE
TO YOU FOR ACTUAL, DIRECT, INDIRECT, CONSEQUENTIAL,
PUNITIVE OR INCIDENTAL DAMAGES EVEN IF YOU GIVE
NOTICE OF THE POSSIBILITY OF SUCH DAMAGE.
1.F.3. LIMITED RIGHT OF REPLACEMENT OR REFUND - If you
discover a defect in this electronic work within 90 days of receiving it, you
can receive a refund of the money (if any) you paid for it by sending a
written explanation to the person you received the work from. If you
received the work on a physical medium, you must return the medium with
your written explanation. The person or entity that provided you with the
defective work may elect to provide a replacement copy in lieu of a refund.
If you received the work electronically, the person or entity providing it to
below.
1.F.
1.F.1. Project Gutenberg volunteers and employees expend considerable
effort to identify, do copyright research on, transcribe and proofread works
not protected by U.S. copyright law in creating the Project Gutenberg™
collection. Despite these efforts, Project Gutenberg™ electronic works, and
the medium on which they may be stored, may contain “Defects,” such as,
but not limited to, incomplete, inaccurate or corrupt data, transcription
errors, a copyright or other intellectual property infringement, a defective or
damaged disk or other medium, a computer virus, or computer codes that
damage or cannot be read by your equipment.
1.F.2. LIMITED WARRANTY, DISCLAIMER OF DAMAGES - Except
for the “Right of Replacement or Refund” described in paragraph 1.F.3, the
Project Gutenberg Literary Archive Foundation, the owner of the Project
Gutenberg™ trademark, and any other party distributing a Project
Gutenberg™ electronic work under this agreement, disclaim all liability to
you for damages, costs and expenses, including legal fees. YOU AGREE
THAT YOU HAVE NO REMEDIES FOR NEGLIGENCE, STRICT
LIABILITY, BREACH OF WARRANTY OR BREACH OF CONTRACT
EXCEPT THOSE PROVIDED IN PARAGRAPH 1.F.3. YOU AGREE
THAT THE FOUNDATION, THE TRADEMARK OWNER, AND ANY
DISTRIBUTOR UNDER THIS AGREEMENT WILL NOT BE LIABLE
TO YOU FOR ACTUAL, DIRECT, INDIRECT, CONSEQUENTIAL,
PUNITIVE OR INCIDENTAL DAMAGES EVEN IF YOU GIVE
NOTICE OF THE POSSIBILITY OF SUCH DAMAGE.
1.F.3. LIMITED RIGHT OF REPLACEMENT OR REFUND - If you
discover a defect in this electronic work within 90 days of receiving it, you
can receive a refund of the money (if any) you paid for it by sending a
written explanation to the person you received the work from. If you
received the work on a physical medium, you must return the medium with
your written explanation. The person or entity that provided you with the
defective work may elect to provide a replacement copy in lieu of a refund.
If you received the work electronically, the person or entity providing it to
Page 485
you may choose to give you a second opportunity to receive the work
electronically in lieu of a refund. If the second copy is also defective, you
may demand a refund in writing without further opportunities to fix the
problem.
1.F.4. Except for the limited right of replacement or refund set forth in
paragraph 1.F.3, this work is provided to you ‘AS-IS’, WITH NO OTHER
WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR ANY PURPOSE.
1.F.5. Some states do not allow disclaimers of certain implied warranties or
the exclusion or limitation of certain types of damages. If any disclaimer or
limitation set forth in this agreement violates the law of the state applicable
to this agreement, the agreement shall be interpreted to make the maximum
disclaimer or limitation permitted by the applicable state law. The invalidity
or unenforceability of any provision of this agreement shall not void the
remaining provisions.
1.F.6. INDEMNITY - You agree to indemnify and hold the Foundation, the
trademark owner, any agent or employee of the Foundation, anyone
providing copies of Project Gutenberg™ electronic works in accordance
with this agreement, and any volunteers associated with the production,
promotion and distribution of Project Gutenberg™ electronic works,
harmless from all liability, costs and expenses, including legal fees, that
arise directly or indirectly from any of the following which you do or cause
to occur: (a) distribution of this or any Project Gutenberg work, (b)
alteration, modification, or additions or deletions to any Project Gutenberg
work, and (c) any Defect you cause.
Section 2. Information about the Mission of Project
Gutenberg
Project Gutenberg is synonymous with the free distribution of electronic
works in formats readable by the widest variety of computers including
obsolete, old, middle-aged and new computers. It exists because of the
electronically in lieu of a refund. If the second copy is also defective, you
may demand a refund in writing without further opportunities to fix the
problem.
1.F.4. Except for the limited right of replacement or refund set forth in
paragraph 1.F.3, this work is provided to you ‘AS-IS’, WITH NO OTHER
WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR ANY PURPOSE.
1.F.5. Some states do not allow disclaimers of certain implied warranties or
the exclusion or limitation of certain types of damages. If any disclaimer or
limitation set forth in this agreement violates the law of the state applicable
to this agreement, the agreement shall be interpreted to make the maximum
disclaimer or limitation permitted by the applicable state law. The invalidity
or unenforceability of any provision of this agreement shall not void the
remaining provisions.
1.F.6. INDEMNITY - You agree to indemnify and hold the Foundation, the
trademark owner, any agent or employee of the Foundation, anyone
providing copies of Project Gutenberg™ electronic works in accordance
with this agreement, and any volunteers associated with the production,
promotion and distribution of Project Gutenberg™ electronic works,
harmless from all liability, costs and expenses, including legal fees, that
arise directly or indirectly from any of the following which you do or cause
to occur: (a) distribution of this or any Project Gutenberg work, (b)
alteration, modification, or additions or deletions to any Project Gutenberg
work, and (c) any Defect you cause.
Section 2. Information about the Mission of Project
Gutenberg
Project Gutenberg is synonymous with the free distribution of electronic
works in formats readable by the widest variety of computers including
obsolete, old, middle-aged and new computers. It exists because of the
Page 486
efforts of hundreds of volunteers and donations from people in all walks of
life.
Volunteers and financial support to provide volunteers with the assistance
they need are critical to reaching Project Gutenberg’s goals and ensuring
that the Project Gutenberg collection will remain freely available for
generations to come. In 2001, the Project Gutenberg Literary Archive
Foundation was created to provide a secure and permanent future for
Project Gutenberg and future generations. To learn more about the Project
Gutenberg Literary Archive Foundation and how your efforts and donations
can help, see Sections 3 and 4 and the Foundation information page at
www.gutenberg.org.
Section 3. Information about the Project Gutenberg
Literary Archive Foundation
The Project Gutenberg Literary Archive Foundation is a non-profit 501(c)
(3) educational corporation organized under the laws of the state of
Mississippi and granted tax exempt status by the Internal Revenue Service.
The Foundation’s EIN or federal tax identification number is 64-6221541.
Contributions to the Project Gutenberg Literary Archive Foundation are tax
deductible to the full extent permitted by U.S. federal laws and your state’s
laws.
The Foundation’s business office is located at 41 Watchung Plaza #516,
Montclair NJ 07042, USA, +1 (862) 621-9288. Email contact links and up
to date contact information can be found at the Foundation’s website and
official page at www.gutenberg.org/contact
Section 4. Information about Donations to the Project
Gutenberg Literary Archive Foundation
Project Gutenberg™ depends upon and cannot survive without widespread
public support and donations to carry out its mission of increasing the
number of public domain and licensed works that can be freely distributed
in machine-readable form accessible by the widest array of equipment
life.
Volunteers and financial support to provide volunteers with the assistance
they need are critical to reaching Project Gutenberg’s goals and ensuring
that the Project Gutenberg collection will remain freely available for
generations to come. In 2001, the Project Gutenberg Literary Archive
Foundation was created to provide a secure and permanent future for
Project Gutenberg and future generations. To learn more about the Project
Gutenberg Literary Archive Foundation and how your efforts and donations
can help, see Sections 3 and 4 and the Foundation information page at
www.gutenberg.org.
Section 3. Information about the Project Gutenberg
Literary Archive Foundation
The Project Gutenberg Literary Archive Foundation is a non-profit 501(c)
(3) educational corporation organized under the laws of the state of
Mississippi and granted tax exempt status by the Internal Revenue Service.
The Foundation’s EIN or federal tax identification number is 64-6221541.
Contributions to the Project Gutenberg Literary Archive Foundation are tax
deductible to the full extent permitted by U.S. federal laws and your state’s
laws.
The Foundation’s business office is located at 41 Watchung Plaza #516,
Montclair NJ 07042, USA, +1 (862) 621-9288. Email contact links and up
to date contact information can be found at the Foundation’s website and
official page at www.gutenberg.org/contact
Section 4. Information about Donations to the Project
Gutenberg Literary Archive Foundation
Project Gutenberg™ depends upon and cannot survive without widespread
public support and donations to carry out its mission of increasing the
number of public domain and licensed works that can be freely distributed
in machine-readable form accessible by the widest array of equipment
Page 487
including outdated equipment. Many small donations ($1 to $5,000) are
particularly important to maintaining tax exempt status with the IRS.
The Foundation is committed to complying with the laws regulating
charities and charitable donations in all 50 states of the United States.
Compliance requirements are not uniform and it takes a considerable effort,
much paperwork and many fees to meet and keep up with these
requirements. We do not solicit donations in locations where we have not
received written confirmation of compliance. To SEND DONATIONS or
determine the status of compliance for any particular state visit
www.gutenberg.org/donate.
While we cannot and do not solicit contributions from states where we have
not met the solicitation requirements, we know of no prohibition against
accepting unsolicited donations from donors in such states who approach us
with offers to donate.
International donations are gratefully accepted, but we cannot make any
statements concerning tax treatment of donations received from outside the
United States. U.S. laws alone swamp our small staff.
Please check the Project Gutenberg web pages for current donation methods
and addresses. Donations are accepted in a number of other ways including
checks, online payments and credit card donations. To donate, please visit:
www.gutenberg.org/donate.
Section 5. General Information About Project Gutenberg
electronic works
Professor Michael S. Hart was the originator of the Project Gutenberg
concept of a library of electronic works that could be freely shared with
anyone. For forty years, he produced and distributed Project Gutenberg
eBooks with only a loose network of volunteer support.
Project Gutenberg eBooks are often created from several printed editions,
all of which are confirmed as not protected by copyright in the U.S. unless a
particularly important to maintaining tax exempt status with the IRS.
The Foundation is committed to complying with the laws regulating
charities and charitable donations in all 50 states of the United States.
Compliance requirements are not uniform and it takes a considerable effort,
much paperwork and many fees to meet and keep up with these
requirements. We do not solicit donations in locations where we have not
received written confirmation of compliance. To SEND DONATIONS or
determine the status of compliance for any particular state visit
www.gutenberg.org/donate.
While we cannot and do not solicit contributions from states where we have
not met the solicitation requirements, we know of no prohibition against
accepting unsolicited donations from donors in such states who approach us
with offers to donate.
International donations are gratefully accepted, but we cannot make any
statements concerning tax treatment of donations received from outside the
United States. U.S. laws alone swamp our small staff.
Please check the Project Gutenberg web pages for current donation methods
and addresses. Donations are accepted in a number of other ways including
checks, online payments and credit card donations. To donate, please visit:
www.gutenberg.org/donate.
Section 5. General Information About Project Gutenberg
electronic works
Professor Michael S. Hart was the originator of the Project Gutenberg
concept of a library of electronic works that could be freely shared with
anyone. For forty years, he produced and distributed Project Gutenberg
eBooks with only a loose network of volunteer support.
Project Gutenberg eBooks are often created from several printed editions,
all of which are confirmed as not protected by copyright in the U.S. unless a
Page 488
copyright notice is included. Thus, we do not necessarily keep eBooks in
compliance with any particular paper edition.
Most people start at our website which has the main PG search facility:
www.gutenberg.org.
This website includes information about Project Gutenberg, including how
to make donations to the Project Gutenberg Literary Archive Foundation,
how to help produce our new eBooks, and how to subscribe to our email
newsletter to hear about new eBooks.
compliance with any particular paper edition.
Most people start at our website which has the main PG search facility:
www.gutenberg.org.
This website includes information about Project Gutenberg, including how
to make donations to the Project Gutenberg Literary Archive Foundation,
how to help produce our new eBooks, and how to subscribe to our email
newsletter to hear about new eBooks.
Page 489
back
Page 490
back
Page 491
back
Page 492
back
Page 493
back
Page 494
back
Page 495
back
Page 496
back
Page 497
back
Page 498
back
Page 499
back
Page 500
back
Page 501
back
Page 502
back
Page 503
back
Page 504
back
Page 505
back
Page 506
back
Page 507
back
Page 508
back
Page 509
back
Page 510
back
Page 511
back
Page 512
back
Page 513
back
Page 514
back
Page 515
back
Page 516
back
Page 517
back
Page 518
back
Page 519
back
Page 520
back
Page 521
back
Page 522
back
Page 523
back
Page 524
back
Page 525
back
Page 526
back
Page 527
back
Page 528
back
Page 529
back
Page 530
back
Page 531
back
Page 532
back
Page 533
back
Page 534
back
Page 535
back
Page 536
back
Page 537
back
Page 538
back
Page 539
back
Page 540
back
Page 541
back
Page 542
back
Page 543
back
Page 544
back
Page 545
back
Page 546
back
Page 547
back
Page 548
back
Page 549
back
Page 550
back
Page 551
back
Page 552
back
Page 553
back
Page 554
back